Thread type to 0.8 MPa to 0.8 MPa. Note) Air operated type is model IR2120 only. Note) Air operated type is model IR3120 only.

Size: px
Start display at page:

Download "Thread type to 0.8 MPa to 0.8 MPa. Note) Air operated type is model IR2120 only. Note) Air operated type is model IR3120 only."

Transcription

1 Precision Regulator Series IR//3 5 Precision Regulator Series IR//3 Features Precise air pressure regulator for instrument applications. Three body sizes available. Pressure unaffected by supply pressure or demand changes. Bracket and pressure gauge can be mounted from directions. Compact and lightweight. Superior relief flow characteristics. Basic type operated type How to Order IR Precision regulator Body size IR Adjustment type IR Handle type 3 IR3 pilot (Note) Note) The IR** type ( operated) is only available for body sizes and 3. F Thread type F G Regulating pressure range For series IR/ For series IR3.5 to. MPa. to. MPa. to.4 MPa. to.4 MPa. to.8 MPa. to.8 MPa Note) operated type is model IR only. Note) operated type is model IR3 only. Port size size 3 4 /8 /4 3/8 / Application IR IR IR3 Note) The IR** type ( operated) is only available for body sizes and 3. Product Recommendation Accessories and Related Products IR-F IR-F IR-F Model Max. supply pressure Min. supply pressure Regulating pressure range Input signal () pressure Sensitivity Repeatability Linearity (3) consumption (4) (At supply pressure of. MPa) Port size Stocked items for fast delivery () Pressure gauge port Ambient and fluid temperature Weight [kg] IR-F IR-F IR-F Specifications IR-F IR3-F IR3-F3 IR IR:.5 to. MPa IR:. to.4 MPa IR:. to.8 MPa /8.4 IR3-F4 IR3-F IR3-F3 Set pressure +.5 MPa IR3-F4 IR3-F IR3-F3 Basic type IR IR:.5 to. MPa IR:. to.4 MPa IR:. to.8 MPa /4.3 IR3-F4 IR3-F3 IR3-F4 IR3. MPa Set pressure +. MPa IR3:. to. MPa IR3:. to.4 MPa IR3:. to.8 MPa Within.% of full span Within ±.5% of full span 4.4 l/min (ANR) or less 4.4 l/min (ANR) or less.5 l/min (ANR) or less 4.4 l/min (ANR) or less /4, 3/8, / /8 ( locations) 5 to 6ºC (No freezing).64 (Accessories) Series G - Pressure Gauges - (Related Products) Series AR - Regulators - page 84 Series ITV - Electro-pneumatic Regulators - page 4 Series ISE - Digital Pressure Switches - page 73 Series AC - Modular Units - page 76 Series AC-A - Modular Units - page 76 operated type IR IR3 Set pressure +.5 MPa. to.8 MPa. to.8 MPa /4.35 Within ±% of full span Note ) With the condition of no flow on the output side. Together with the set pressure, be sure to maintain a minimum differential pressure of.5 MPa for models IR and IR, and. MPa for model IR3. Note ) Applicable only to air operated types IR and IR3. Note 3) Indicates the linearity of the output pressure with respect to the input signal pressure. Note 4) is normally being discharged to the atmosphere from a bleed hole or an exhaust port. Set pressure +. MPa. to.8 MPa. to.8 MPa.5 l/min (ANR) or less /4, 3/8, /.7

2 6 Series IR//3 Precision Regulator Accessory (Option)/Part No. Description IR Bracket Pressure gauge G33-- Accuracy 3% (Full span) IR P363 G33-4- IR G33-- IR G43-- Part no. IR P368 G43-4- IR/ G43-- IR3 G43-- IR3 P363- G43-4- IR3/3 G43-- Spares Kits Applicable model Spares kit IR KT-IR IR KT-IR IR3 KT-IR3 Dimensions IR- IR- ø3 M5X Bleed SUP() 4.5 () 35 EXH - /8 35 Port size - /8 Pressure gauge port Panel mounting hole Max. 4 Panel ø ø8.5 Mounting hole Bracket (Option) Pressure gauge (Option) M6 x P.5 Exhaust ø43 ø.5 Panel mounting hole Panel 6 Max Bleed SUP() ø /4 Port size /8 Pressure gauge port 3 () 5 Mounting hole 36 Bracket (Option) Pressure gauge (Option) IR Mounting hole Bracket (Option) Pressure gauge (Option) ø.5 Panel mounting hole Max. 4 ø43 M6 x P.5 EXH(3) Bleed SUP() 9 ø5.5 () Panel / Exhaust port - /4 to / Port size 66 - /8 Pressure gauge port

3 Compact Electro-Pneumatic Regulator Series ITV/9 7 Compact Electro-Pneumatic Regulator Series ITV/9 RoHS Features Realizes space-savings and reduction of weight. Built-in one touch fitting. Error indication LED display. Equivalent to IP65. High speed response time. sec. High stability. Can be manifold mounted. Vacuum variant available. How to Order ITV For single unit and single unit for manifold Pressure range MPa.5 MPa.9 MPa kpa 3 ITV 3 N Power supply voltage 4 VDC to 5 VDC Input signal Current type 4 to ma DC (Sink type) Current type to ma DC (Sink type) Voltage type to 5 VDC Voltage type to VDC Base type M Cable Assembly N S L Without cable connector 3m length with straight connector. m length with right angle connector. For single unit For manifolds How to Order ITV/9 Manifold IITV 3 Stations stations 3 stations stations Note) A DIN rail with the length specified by the number of stations is attached to the manifold. For dimensions of the DIN rail, refer to the external dimensions. Product Recommendation Stocked items for fast delivery ITV-N ITV-MN ITV-3MN ITV-3N ITV3-N ITV3-MN ITV3-N ITV3-3MN ITV3-3N ITV5-MN ITV5-N ITV5-3MN ITV5-3N ITV9-3N IITV- IITV-4 Related Products Series AC - - page 76 Series PFA - Digital Flow Switch for - page 39 Series ZSE/ISEA - Digital Pressure Switch for - page 73 Series KQ - Fittings - page 84 Series TU - Tubing - page 3

4 8 Series ITV/9 Compact Electro-Pneumatic Regulator Standard Specifications Model Min. supply pressure ITV ITV3 Set pressure +. MPa ITV5 ITV9 Set pressure kpa Max. supply pressure. MPa. MPa kpa Regulating pressure range. to. MPa. to.5 MPa. to.9 MPa to kpa Voltage 4 VDC ±%, to 5 VDC Power supply Current consumption Power supply voltage 4 VDC type:. A or less Power supply voltage to 5 VDC type:.8 A or less Input signal Input impedance Output signal Linearity Hysteresis Repeatability Sensitivity Within ±% (Full span) Within.5% (Full span) Within ±.5% (Full span) Within.% (Full span) Voltage type Voltage type Analogue to 5 VDC, to VDC Approximately kω to 5 VDC (Output impedance: approximately kω) Current type Current type output 4 to madc, to madc (Sink type) Approximately 5 Ω Output accuracy: Within ±6% (Full span) Temperature characteristics Operating temperature range Enclosure Connection type Within ±.% (Full span)/ºc to 5ºC (With no condensation) IP65 equivalent Built-in One-touch fittings Connection size For single unit Metric size z, x, c: ø4 Manifold Metric size z, c: ø6, x: ø4 Weight () g or less (without options) Note ) Indicates the weight of a single unit. For IITV-n Total weight [g] Stations (n) x + 3 (Weight of end block A, B assembly) + Weight [g] of DIN rail Note ) Specifications other than the following are optional. Pressure range:. MPa,.5 MPa,.9 MPa, Power supply voltage: 4 VDC, Input signal: to VDC Note 3) When there is a downstream flow consumption, pressure may become unstable depending on piping conditions. When using under the conditions equivalent to IP65, connect the fitting or tube to the breathing hole prior to use. Option Bracket Flat bracket assembly P398 Cable connector (spare) Straight type M8-4DSX3MG4 L-bracket assembly P3983 Right angle type (spare) P398-S- Tighting torque when assembling is.3 N m.

5 Compact Electro-Pneumatic Regulator Series ITV/9 9 Fluiid Characteristics Series ITV Linearity, Hyteresis Repeatability With 5% of signal input Output deviation factor (% F.S.) Return Out Output deviation factor (% F.S.) Input signal (%F.S.) 3 4 Count 5 Pressure Characteristics Set pressure:.5 MPa Flow Characteristics Supply pressure:. MPa Output deviation factor (% F.S.).5.5 Out Return Set pressure [kpa] kpa 8 kpa 6 kpa 4 kpa kpa kpa Supply pressure [MPa] Flow rate [l/min (ANR)] 4 Series ITV3 Linearity, Hyteresis.8 Output deviation factor (% F.S.) Return Out Repeatability Output deviation factor (% F.S.).5.5 With 5% of signal input Input signal (%F.S.) 3 4 Count 5 Pressure Characteristics Set pressure:.5 MPa Flow Characteristics Supply pressure:.6 MPa 6 Output deviation factor (% F.S.).5.5 Out Return Set pressure [kpa] kpa 4 kpa 3 kpa kpa kpa 5 kpa Supply pressure [MPa] Flow rate [l/min (ANR)] 7

6 3 Series ITV/9 Compact Electro-Pneumatic Regulator Flow Characteristics Series ITV5 Linearity, Hyteresis.8 Output deviation factor (% F.S.) Return Out Input signal (%F.S.) Repeatability Output deviation factor (% F.S.) Count With 5% of signal input 5 Pressure Characteristics Output deviation factor (% F.S.).5.5 Out Return Supply pressure [MPa] Set pressure:.45 MPa. Flow Characteristics Supply pressure:. MPa Set pressure [kpa] 9 9 kpa 8 kpa kpa 6 6 kpa 5 kpa kpa 3 3 kpa kpa kpa 5 kpa Flow rate [l/min (ANR)] Series ITV9 Linearity, hysteresis Repeatability With 5% of signal input Output deviation factor % F.S Return Out Output deviation factor % F.S Input signal % F.S Repetition 5 Pressure characteristics Output deviation factor % F.S Out Return Flow characteristics Set pressure kpa kpa kpa - 4kPa -4 6kPa -6 8kPa -8 kpa Supply pressure MPa Flow rate l/min (ANR) 4

7 Compact Electro-Pneumatic Regulator Series ITV/9 3 Dimensions For Single Unit Port Location No. ITV 3 SUP 5 ITV9 z x c VAC EXH ATM Flat bracket (Option) ø3.5 L-bracket (Option) 7 6-ø Note) When useing under the conditions equivalent to IP65, connect the fitting or tube to the bleed hole prior to use SUP, VAC port (ø4) EXH, ATM port (ø4) x -M3 thread depth 3.5 Bracket mounting hole Flat bracket (Option) 89 SUPz VACz EXHc ATMc Note) Breathing hole (M3) port (ø4) L-bracket (Option) ø6 -ø6 PWR ERR PWR ERR L-bracket (Option) (3.9) Flat bracket (Option) M8 x Cable connection thread Minimium bending radius 8 Body 4 Cable connector (4-wire) Straight type (Option) Cable connector (4-wire) Right angle type (Option) Minimium bending radius 8 Body.8 M8 x ø ø4

8 3 Series ITV/9 Compact Electro-Pneumatic Regulator Dimensions for Single Unit for Manifold Bushing assembly Note) Breathing hole (M3) x port (ø4) M8 x 56 Cable connection thread 5 PWR ERR Note) When using under the conditions equivalent to IP65, connect a fitting or tube to the bleed hole prior to use. Dimensions for Manifold 56 D side stations U side 5 3 L L Note) Breathing hole (M3) 9.5 SUP, VACzport (ø) EXH, ATMcport (ø6) xport (ø4) PWR ERR PWR ERR (8) Dimensions in inch are noted in parentheses PWR 5 ERR PWR ERR 4 4 Port Location No. z x c ITV 3 SUP EXH 5 ITV9 VAC ATM Note) Stations are counted starting from the D side. Note) For dimensions of the cable connector, refer to single unit. Manifold stations n L L M3 thread depth 3 Mounting hole [mm] Note) When using under the conditions equivalent to IP65, connect the fittings or tubing to the bleed hole prior to use.

9 Compact Electro-Pneumatic Regulator Series ITV/9 33 Precautions Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage. Further, use DC power with sufficient capacity and a low ripple. Brown Blue White Black Note) Body Terminal No. 3 4 Lead wire colour Brown White Blue Black Wiring Power Signal COM Monitor : (White) 4: (Black) : (Brown) 3: (Blue) Note) A right angle type cable is also available. The entry direction for the right angle type connector is to downwards (SUP port side). Never turn the connector as it is not designed to turn. Using force to turn the connector will damage the connector coupling. Wiring Diagrams Current signal type Brown Vs A Blue White Black Voltage signal type Brown Vs Vin Blue White Black Vs: Power Supply 4 VDC ±% to 5 VDC A : Input signals 4 to ma DC to ma DC Monitor output wiring diagram Analogue output, voltage type Monitor output voltage Vs : Power Supply 4 VDC ±% to 5 VDC Vin: Input signals to 5 VDC to VDC Brown Blue White Black

10 34 Series ITV//3 Electro-Pneumatic Regulator Electro-Pneumatic Regulator Series ITV//3 RoHS Features Compact and Lightweight. Low power consumotion, less than 4W. Low sensitivity, less than.% (F.S.) Equivalent to IP65. Linearity: Within ±% (F.S.) Low hysteresis, less than ±.5% (F.S.) Fieldbus protocol compatibility: - CC-Link - DeviceNet - Profibus How to Order Power supply voltage 3 Model 3 ITV 3 CC DN PR RC 3 Pressure range 3 5 4VDC to 5 VDC. MPa.5 MPa.9 MPa Product Recommendation Input signal Current 4 to ma (Sink type) Current to ma (Sink type) Voltage to 5 VDC Voltage to VDC CC Link DeviceNet TM Profibus DP RS3C Communication Thread type F G F Monitor output 3 4 N Port size 3 4 N S L /8 ( model) /4 (,, 3 model) 3/8 (, 3 model) / (3 model) None (for communication models) Analogue output to 5V DC Switch output/npn output Switch output/pnp output Analogue output 4 to ma DC (sink type) Cable Assembly Without cable connector 3m length straight connector 3m length right angle connector Note) Order communication cable (other than RS3C) separately. Monitor output 3 Unit Mpa Bar Note) Note) Option not available for communication models, as it does not have a pressure display. Stocked items for fast delivery ITV-FN ITV-FN ITV-3FN ITV-3FN ITV-33FN ITV3-FN ITV3-3FN ITV3-3FN ITV3-3FN ITV3-33FN ITV3-PRFN ITV5-FN ITV5-FN ITV5-3FN ITV5-3FN ITV5-3FN ITV5-33FN ITV5-33FN ITV5-PRFN ITV-FN ITV-F3N ITV-3F3N ITV3-FN ITV3-F3N ITV3-3F3N ITV3-3FN ITV3-3F3N ITV3-33FN ITV3-33F3N ITV3-PRFN ITV3-PRF3N ITV5-FN ITV5-F3N ITV5-3F3N ITV5-3FN ITV5-3F3N ITV5-33F ITV5-33F3N ITV5-PRFN ITV5-PRF3N ITV3-F4N ITV3-3F4N ITV3-3F4N ITV3-33F4N ITV33-F4N ITV33-3F4N ITV33-3F4N ITV33-33F4N ITV35-F4N ITV35-3F3N ITV35-3F3N ITV35-3F4N ITV35-33F3N ITV35-33F4N ITV35-PRF3N Related Products Series AC - - page 7 Series PFA - Digital Flow Switch for - page 39 Series ZSE/ISEA - Digital Pressure Switch for - page 73 Series KQ - Fittings - page 84 Series TU - Tubing - page 3

11 Electro-Pneumatic Regulator Series ITV//3 35 Specifications Model Minimum supply pressure Maximum supply pressure. Note ) Set pressure range Voltage Power supply Current consumption Current type Note ) Input signal Voltage type Preset input Current type Input impedance Note 3) Output signal (monitor output) Linearity Hysteresis Repeatability Sensitivity Temperature characteristics Output pressure Accuracy display Note 4) Minimum unit Ambient and fluid temperature Enclosure Weight Note 9) Voltage type Preset input Analogue output Switch output ITV ITV ITV3 ITV ITV3 ITV5 ITV ITV3 ITV5 ITV3 ITV33 ITV35 Set pressure +. MPa MPa. MPa.5 to. MPa.5 to.5 MPa.5 to.9 MPa Note ) Note ) Note ) 4 VDC ±%, to 5 VDC Power supply voltage 4 VDC type:. A or less Power supply voltage to 5 VDC type:.8 A or less 4 to ma DC, to ma DC (Sink type) to 5 VDC, to VDC 4 points (Negative common), 6 points (no common polarity) 5Ω or less Note 6) Approx. 6.5 kω Power supply voltage 4 VDC type: Approx. 4.7 kω Power supply voltage VDC type: Approx.. kω to 5 VDC (Output impedance: Approximately kω) 4 to ma DC (Sink type) (Load impedance: 5 Ω or less) Output accuracy within ±6% (Full span) NPN open collector output: Max. 3 V, 8 ma PNP open collector output: Max. 8 ma Within ±% (Full span) Within.5% (Full span) Within ±.5% (Full span) Within.% (Full span) Within ±.% (Full span)/ºc ±%F.S. ± digit or less MPa:., kgf/cm :., bar:., psi:. Note 5), kpa: to 5ºC (No condensation) IP65 Approx. 5 g (without options) Approx. 35 g (without options) Approx. 645 g (without options) Note ) Please refer to Figure for the relationship between set pressure and input. Because the maximum set pressure differs for each pressure display. Note ) -wire type 4 to ma DC is not available. Power supply voltage (4 VDC or to 5 VDC) is required. Note 3) Select either analogue output or switch output. Further, when switch output is selected, select either NPN output or PNP output. When measuring ITV analogue output from to 5VDC, if the load impedance is less than kω, the analogue output monitor accuracy of within ±6% (full span) may not be available. The product with the accuracy of within ±6% is supplied upon your request. Output pressure remains unaffected. Note 4) Adjustment of numerical values such as the zero/span adjustment or preset input type is set based on the minimum units for output pressure display (e.g.. to.5 MPa). Note that the unit cannot be changed. Note 5) The minimum unit for.9 MPa (3 psi) types is psi. Note 6) Value for the state with no over current circuit included. If an allowance is provided for an over current circuit, the input impedance varies depending on the input current. This is 35Ω or less for an input current of ma DC. Note 7) The above characteristics are confined to the static state. When air is consumed on the output side, the pressure may fluctuate. Note 8) For communication models, the maximum current consumption is.6 A or less. Note 9) For communication models, add roughly 8 g to the weight ( g for the PROFIBUS DP). Note ) The ITV series is a Grease-free specification (Wetted parts). Rated pressure Output pressure [MPa] This range is outside of the control (output)..5mpa Input signal (%F.S.) Figure. Input/output characteristics chart Communication Specifications (CC, DN, PR, RC) Model Protocol Note ) Version Communication speed ITV-CC CC-Link Ver. 56 k/65 k.5 M/5 M/ M bps ITV-DN DeviceNet Release. 5 k/5 k/5 k bps ITV-PR PROFIBUS DP DP-V 9.6 k/9. k/45.45 k k/87.5 k/5 k.5 M/3 M/6 M/ M bps ITV-RC RS-3C Configulation file Note ) EDS GSD I/O occupation area 4 word/4 word, 3 bit/3 bit 6 bit/6 bit 6 bit/6 bit (input/output data) (per station, remote device station) Communication data resolution bit (496 resolution) bit (496 resolution) bit (496 resolution) bit (4 resolution) HOLD HOLD/CLEAR Fail safe Note 3) /CLEAR CLEAR HOLD (Switch setting) (Switch setting) Electric insulation Note 4) No No Yes No Terminating Built into the product resistor (Switch setting) Note ) Note that version information is subject to change. Note ) Configulation files can be downloaded from the SMC's website: Note 3) The output HOLD value when a CC-Link communications error occurs can be set based on the bit area data. Note 4) The insulation between the electrical signal of the communication system and ITV power supply. 9.6 kbps

12 36 Series ITV//3 Electro-Pneumatic Regulator Combinations Standard specifications Combination possible Combination not possible ITV models are not applicable. Applicable model rspacer ITV Specifications ITV ITV3 Approx. 89 Approx el-bracket Standard specifications Accessories Set pressure max.. MPa Set pressure max..5 MPa Set pressure max..9 MPa Connection G /4 Connection G 3/8 Connection G / Flat Bracket L-Bracket 3 5 F F3 F4 qaf3 wafm3 Approx. 43 Approx. 7 ITV3 Modular Products and Accessory Combinations Applicable products and accessories q filter wmist separator el-bracket rspacer tspacer with L-bracket (e + r) yspacer with T-bracket ITV models are not applicable. Applicable model ITV ITV3 AF3 AF4 AFM3 AFM4 B3L B4L Y3 Y4 Y3L Y4L Y4T Flat bracket assembly (including mounting screws) L-bracket assembly (including mounting screws) Power cable connector Description Straight type 3 m Right angle type 3 m Part No. ITV ITV ITV3 KT-ITV-F KT-ITV-F KT-ITV-L KT-ITV-L P (P for DeviceNet ) P (P for DeviceNet ) Bus adapter (CC-Link model only) EX9-ACY-MJ Flat bracket.6 6 L-bracket x ø4.5 4 x ø5.5 7 Accessories (Option)/Part No. qaf4 34 wafm4 Dimensions 4 x ø x ø4.5 4 x ø (8.5) x R3.5

13 Electro-Pneumatic Regulator Series ITV//3 37 Flow Characteristics Series ITV Linearity Set pressure [MPa] Hysteresis... Out Return Input signal (%F.S.) Output deviation factor (%F.S.) Input signal (%F.S.) Repeatability Output deviation factor (%F.S.) Repetition Pressure characteristics Output deviation factor (%F.S.) Set pressure:.5 MPa..5 Set point Supply pressure [MPa] Flow characteristics Set pressure [MPa] Supply pressure:. MPa Flow rate [l/min (ANR)] Relief flow characteristics Set pressure [MPa] Supply pressure:. MPa Flow rate [l/min (ANR)] Series ITV Linearity Set pressure [MPa] Input signal (%F.S.) Hysteresis Output deviation factor (%F.S.) Out Return Input signal (%F.S.) Repeatability Output deviation factor (%F.S.) Repetition Pressure characteristics Output deviation factor (%F.S.) Set pressure:.5 MPa..5 Set point Supply pressure [MPa] Flow characteristics Set pressure [MPa] Supply pressure:. MPa Flow rate [l/min (ANR)] Relief flow characteristics Set pressure [MPa] Supply pressure:. MPa Flow rate [l/min (ANR)]

14 38 Series ITV//3 Electro-Pneumatic Regulator Flow Characteristics Series ITV3 Linearity Set pressure [MPa] Input signal (%F.S.) Hysteresis Output deviation factor (%F.S.) Out Input signal (%F.S.) Return Repeatability Output deviation factor (%F.S.) Repetition Pressure characteristics Output deviation factor (%F.S.) Set pressure:.5 MPa..5 Set point Supply pressure [MPa] Flow characteristics Set pressure [MPa] Supply pressure:. MPa Flow rate [l/min (ANR)] Relief flow characteristics Set pressure [MPa] Supply pressure:. MPa Flow rate [l/min (ANR)] Series ITV3 Linearity Set pressure [MPa] Hysteresis Output deviation factor (%F.S.) Out Return Repeatability Output deviation factor (%F.S.) Input signal (%F.S.) Input signal (%F.S.) Repetition Pressure characteristics Output deviation factor (%F.S.) Set pressure:. MPa..5 Set point Supply pressure [MPa] Flow characteristics Set pressure [MPa] Supply pressure:.7 MPa Flow rate [l/min (ANR)] Relief flow characteristics Set pressure [MPa] Supply pressure:.7 MPa. 5 5 Flow rate [l/min (ANR)]

15 Electro-Pneumatic Regulator Series ITV//3 39 Flow Characteristics Series ITV3 Linearity Set pressure [MPa] Hysteresis Output deviation factor (%F.S.) Out Return Repeatability Output deviation factor (%F.S.) Input signal (%F.S.) Input signal (%F.S.) Repetition Pressure characteristics Output deviation factor (%F.S.) Set pressure:. MPa Set point Flow characteristics Set pressure [MPa] Supply pressure:.7 MPa Relief flow characteristics Set pressure [MPa] Supply pressure:.7 MPa Supply pressure [MPa] Flow rate [l/min (ANR)]. 5 5 Flow rate [l/min (ANR)] Series ITV33 Linearity Set pressure [MPa] Hysteresis Output deviation factor (%F.S.) Out Retirm Repeatability Output deviation factor (%F.S.) Input signal (%F.S.) Input signal (%F.S.) Repetition Pressure characteristics Output deviation factor (%F.S.) Set pressure:. MPa Set point Flow characteristics Set pressure [MPa] Supply pressure:.7 MPa Relief flow characteristics Set pressure [MPa] Supply pressure:.7 MPa Supply pressure [MPa] Flow rate [l/min (ANR)]. 3 4 Flow rate [l/min (ANR)] 5

16 4 Series ITV//3 Electro-Pneumatic Regulator Flow Characteristics Series ITV5 Linearity Set pressure [MPa] Input signal (%F.S.) Hysteresis Output deviation factor (%F.S.) Out Return Input signal (%F.S.) Repeatability Output deviation factor (%F.S.) Repetition Pressure characteristics Output deviation factor (%F.S.) Set pressure:.4 MPa..5 Set point Supply pressure [MPa] Flow characteristics Supply pressure:. [MPa] Flow rate [l/min (ANR)] Supply pressure:. MPa Relief flow characteristics Set pressure [MPa] Supply pressure:. MPa Flow rate [l/min (ANR)] Series ITV5 Linearity Set pressure [MPa] Input signal (%F.S.) Hysteresis Output deviation factor (%F.S.) Out Return Input signal (%F.S.) Repeatability Output deviation factor (%F.S.) Repetition Pressure characteristics Output deviation factor (%F.S.) Set pressure:.4 MPa..5 Set point Supply pressure [MPa] Flow characteristics Set pressure [MPa] Supply pressure:. MPa Flow rate [l/min (ANR)] Relief flow characteristics Set pressure [MPa] Supply pressure:. MPa Flow rate [l/min (ANR)]

17 Electro-Pneumatic Regulator Series ITV//3 4 Flow Characteristics Series ITV35 Linearity..9 Hysteresis. Repeatability. Set pressure [MPa] Input signal (%F.S.) Output deviation factor (%F.S.).5 Out. Return Input signal (%F.S.) Output deviation factor (%F.S.) Pressure characteristics..5 Set point Supply pressure [MPa] Flow characteristics Repetition Output deviation factor (%F.S.) Set pressure:.4 MPa Set pressure [MPa] Flow rate [l/min (ANR)] Supply pressure:. MPa Relief flow characteristics Set pressure [MPa] Flow rate [l/min (ANR)] Supply pressure:. MPa

18 4 Series ITV//3 Electro-Pneumatic Regulator Dimensions ITV Flat bracket.5 () M x Connector (Plug type) Solenoid valve EXH Rc /8 Exhaust port 7 M3 x.5 Solenoid valve EXH Flat bracket assembly KT-ITV-F (Option) EXH (3) x Rc /8, /4 SUP port, port 9.5 SUP () () Flat bracket assembly KT-ITV-F (Option) x M4 x.7 thread depth 6 mm through Right angle type (4-wire) Cable connector 3 m Straight type (4-wire) Cable connector 3 m (33) x ø7 Mounting hole 5 4 Setting part Note) Do not attempt to rotate, as the cable connector does not turn. L-bracket 4 x R3.5 L-bracket assembly KT-ITV-L (Option) L-bracket assembly KT-ITV-L (8.5) 33 (Option) 5 7

19 Electro-Pneumatic Regulator Series ITV//3 43 Dimensions (CC-Link, DeviceNet, PROFIBUS DP and RS-3C) CC-Link/ITV-CC M x Communication cable connection thread (Plug type) M x BUS adapter (53) M x Communication cable connection thread (Socket type) M x Power cable connection thread () DeviceNet /ITV-DN 8.5 M x Communication cable connection thread M x Power cable connection thread () 8.5 Solenoid valve EXH 9.5 x Rc /8, /4 SUP port, port M3 x.5 Solenoid valve EXH Rc /8 Exhaust port SUP () () EXH (3) 4 8 Rc /8 Pressure gauge connection port Solenoid valve EXH 9.5 x Rc /8, /4 SUP port, port Rc /8 Exhaust port EXH (3) M3 x.5 Solenoid valve EXH SUP () () 4 98 Rc /8 Pressure gauge connection port PROFIBUS DP/ITV-PR M reverse connector Communication cable connection thread Solenoid valve EXH 9.5 (6) 4 M x Power cable connection thread () M3 x.5 Solenoid valve EXH Rc /8 Exhaust port SUP () () EXH (3) 8 RS-3C/ITV-RC Solenoid valve EXH Rc /8 Exhaust port EXH (3) M x Communication cable connection thread M x Power cable connection thread M3 x.5 Solenoid valve EXH SUP () () 4 () 98 x Rc /8, /4 SUP port, port Rc /8 Pressure gauge connection port x Rc /8, /4 SUP port, port Rc /8 Pressure gauge connection port CC DN With power cable connector ITV- PR RC Note) Communication cable (other than RS-3C) should be obtained separately. common dimensions Cable connector (4 wire) Right angle type Cable connector (4 wire) Straight type (33) Note) Do not attempt to rotate, as the cable connector does not turn.

20 44 Series ITV//3 Electro-Pneumatic Regulator Dimensions ITV Flat bracket.5 M x Connector (Plug type) 93 Right angle type (4-wire) Cable connector 3 m Straight type (4-wire) Cable connector 3 m () Solenoid valve EXH Rc /4 Exhaust port M5 x.8 Solenoid valve EXH 3.5 Flat bracket assembly KT-ITV-F (Option) EXH (3) 9 SUP () () Flat bracket assembly KT-ITV-F (Option) x Rc /4, 3/8 SUP port, port x M5 x.8 thread depth 6 mm through (33) 4 x ø7 Mounting hole Note) Do not attempt to rotate, as the cable connector does not turn. L-bracket 4 x R3.5 L-bracket assembly KT-ITV-L (Option) (8.5) L-bracket assembly KT-ITV-L (Option)

21 Electro-Pneumatic Regulator Series ITV//3 45 Dimensions (CC-Link, DeviceNet, PROFIBUS DP and RS-3C) Solenoid valve EXH Solenoid valve EXH CC-Link/ITV-CC BUS adapter M x Reverse connector M x 8.5 x Rc /4,3/8 SUP port, port (6) (53) M5 x.8 Solenoid valve EXH Rc/4 Exhaust port SUP() EXH(3) M5 x.8 Solenoid valve EXH Rc/4 Exhaust port SUP() EXH(3) M x Communication cable connection thread M x Power cable connection thread PROFIBUS DP/ITV-PR M reverse connector Communication cable connection thread () M x Power cable connection thread () () 3 () 3 DeviceNet /ITV-DN Solenoid valve EXH Solenoid valve EXH 8.5 x Rc /4,3/8 SUP port, port RS-3C/ITV-RC 8.5 M5 x.8 Solenoid valve EXH Rc/4 Exhaust port EXH(3) SUP() Rc/4 Exhaust port EXH(3) SUP() M x Communication cable connection thread M x Communication cable connection thread M5 x.8 Solenoid valve EXH 36 M x Power cable connection thread () M x Power cable connection thread () () () x Rc /4,3/8 SUP port, port 36 x Rc /4,3/8 SUP port, port 36 CC DN With power cable connector ITV- PR common dimensions RC Note) Communication cable (other than RS-3C) should be obtained separately. Cable connector (4 wire) Right angle type Cable connector (4 wire) Straight type (33) Note) Do not attempt to rotate, as the cable connector does not turn.

22 46 Series ITV//3 Electro-Pneumatic Regulator Dimensions ITV3 Flat bracket.5 () M x Connector (Plug type) Solenoid valve EXH M5 x.8 Solenoid valve EXH EXH (3) (66) Flat bracket assembly KT-ITV-F (Option) 5 SUP () () Flat bracket assembly KT-ITV-F (Option).6 4 x M5 x.8 thread depth 6 mm through Right angle type (4-wire) Cable connector 3 m 36 Straight type (4-wire) Cable connector 3 m x Rc /4, 3/8, /4 SUP port, port x ø7 Mounting hole (33) Note) Do not attempt to rotate, as the cable connector does not turn. L-bracket L-bracket assembly KT-ITV-L (Option) (8.5) x R3.5 7 L-bracket assembly KT-ITV-L (Option)

23 Electro-Pneumatic Regulator Series ITV//3 47 Dimensions (CC-Link, DeviceNet, PROFIBUS DP and RS-3C) CC-Link/ITV3-CC M x Reverse connector M x BUS adapter Solenoid valve EXH 8.5 x Rc /4, 3/8, / SUP port, port Rc / Exhaust port EXH (3) (6) (53) M x Communication cable connection thread M x Power cable connection thread 36 Rc /4 Pressure gauge connection port () 5 SUP () () PROFIBUS DP/ITV3-PR M reverse connector Communication cable connection thread x M5 x.8 thread depth 6 mm through Mounting hole M x Power cable connection thread () DeviceNet /ITV3-DN Solenoid valve EXH M x Communication cable connection thread x Rc /4, 3/8, / SUP port, port RS-3C/ITV3-RC 8.5 M x Power cable connection thread () 4 Rc / Exhaust port EXH (3) SUP () () M x Communication cable connection thread 36 Rc /4 Pressure gauge connection port 4 x M5 x.8 thread depth 6 mm through Mounting hole M x Power cable connection thread () Solenoid valve EXH 5 Solenoid valve EXH Rc / Exhaust port EXH (3) SUP () () Rc / Exhaust port EXH (3) SUP () () x Rc /4, 3/8, / SUP port, port 36 Rc /4 Pressure gauge connection port 4 x M5 x.8 thread depth 6 mm through Mounting hole x Rc /4, 3/8, / SUP port, port 36 Rc /4 Pressure gauge connection port 4 x M5 x.8 thread depth 6 mm through Mounting hole With power cable connector ITV3- CC DN PR RC common dimensions (33) Cable connector (4 wire) Right angle type Cable connector (4 wire) Straight type Note) Do not attempt to rotate, as the cable connector does not turn.

24 48 Series ITV//3 Electro-Pneumatic Regulator Precautions Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage. Further, use DC power with sufficient capacity and a low ripple. Brown Blue White Black Note) 3: (Blue) : (Brown) 4: (Black) : (White) Wiring diagram Current signal type Brown Blue Vs White Black A Voltage signal type Brown Blue Vs White Black Vin Body Current Signal Type Voltage Signal Type Brown Power supply White Input signal 3 4 Blue Black GND (COMMON) Monitor output Communication connector DeviceNet Power RESET Communication connector Power supply connector PROFIBUS DP Communication connector Pin No IN/ communication connector DeviceNet DRAIN V+ V CAN_H CAN_L CC-Link SLD DB DG DA NC Preset Input Type Brown Power supply White Input signal 3 4 Blue Black GND (COMMON) Input signal CC-Link DeviceNet, RS-3C 4 3 Power supply connector Power supply connector PROFIBUS DP NC RxD/TxD-N NC RxD/TxD-P NC RS-3C NC TxD RxD GND NC Vs : Power supply A : Input signal Preset input type Vs S S Vs : Power supply 4 VDC to 5 VDC S S Preset pressure Analogue output: Voltage type Monitor output voltage OFF OFF P 4 VDC to 5 VDC Vs : Power supply 4 VDC to 5 VDC 4 to madc Vin: Input signal to 5 VDC to madc to VDC Brown Blue White Black One of the preset pressures P through P4 is selected by the ON/OFF combination of S and S. ON OFF P OFF ON P3 Monitor output wiring diagram ON ON P4 For safety reasons, it is recommended that one of the preset pressures be set to MPa. Preset pressures are set based on the minimum unit for output display. MPa. kgf/cm. bar. psi. Brown Blue White Black kpa Note that this is psi for 3-psi types. Analogue output: Current type (Sink type) Monitor output voltage Brown Blue White Black Pin No. 3 4 CC-Link Vcc FG GND NC Power supply connector DeviceNet Vcc No connection GND No connection PROFIBUS DP Vcc NC GND NC RS-3C Vcc NC GND FG Note) The cable is also available in a right-angle type. A right-angle type connector is attached facing left (towards the SUP port). On communication models, the connector faces backwards (towards the EXH port). Do not attempt to rotate, as the connector does not turn. Trademark Information DeviceNet is a trademark of ODVA. Switch output: NPN type Load Brown Blue White Black Switch output: PNP type Load Blue Brown White Black When 3 madc or more is applied, detecting device for overcurrentstarts activating and then emits an error signal. (Error number 5 )

25 Electronic Vacuum Regulator Series ITV9/9 49 Electronic Vacuum Regulator Series ITV9/9 RoHS Features Stepless control of vacuum pressure proportional to an electrical signal. Current or voltage input types. Monitor output as standard. V and 4V power versions. Fieldbus protocol compatibility: - CC-Link - DeviceNet - Profibus How to Order Pressure range 9.3 to 8 kpa 3 CC DN PR RC 3 4 ITV 9 F N 5 Power supply voltage 4VDC to 5 VDC Note) Communication models are only available for 4VDC. Input signal Current 4 to ma (Sink type) Current to ma (Sink type) Voltage to 5 VDC Voltage to VDC CC Link DeviceNet TM Profibus DP RS3C Communication Monitor output None (for communication models) Analogue output to 5V DC Switch output/npn output Switch output/pnp output Analogue output 4 to ma DC (single type) Pressure display unit 5 kpa None Note) Note) For the communication models, only Nil available as it does not have a pressure display Cable Assembly Port size N S L Without cable connector 3m length straight connector 3m length right angle connector /4 Note) Order communication cable (Other than RS3C) separately. Thread type F G Straight type Right angle type Product Recommendation Stocked items for fast delivery ITV9-3FN5 ITV9-3FN5 ITV9-33FN5 Related Products Series AC - - page 7 Series PFA - Digital Flow Switch for - page 39 Series ZSE/ISEA - Digital Pressure Switch for - page 73 Series KQ - Fittings - page 84 Series TU - Tubing - page 3

26 5 Series ITV9/9 Electronic Vacuum Regulator Specifications Power supply Note ) Minimum supply vacuum pressure Maximum supply vacuum pressure Set pressure range Note ) Current type Input signal Voltage type Preset input Current type Input Voltage type impedance Preset input Output signal (Monitor output) Linearity Hysteresis Repeatability Sensitivity Temperature characteristics Output pressure Accuracy display Units Ambient and fluid temperature Enclosure Note 7) Weight Model Voltage Current consumption Note 4) Analogue output Switch output ITV9 ITV9 4 VDC ±% to 5 VDC Note 6) Power supply voltage 4 VDC type:. A or less Power supply voltage to 5 VDC type:.8 A or less Set pressure 3.3 kpa kpa.3 to 8 kpa 4 to ma, to ma (single type) to 5 VDC, to VDC 4 points (negative common); 6 points (no common polarity) Note 3) 5Ω or less Approximately 6.5 kω Power supply voltage 4VDC type: Approximately 4.7 kω Power supply voltage VDC type: Approximately. kω to 5 VDC (Load impedance: Approximately kω) 4 to ma (Sink type) (Load impedance: 5 Ω or less) Output accuracy within 6% (Full span) NPN open collector output: Max. 3 V, 3 ma PNP open collector output: Max. 3 ma Within ±% (Full span) Within.5% (Full span) Within ±.5% (Full span) Within.% (Full span) Within ±.% (Full span)/ºc ±% F.S. ± digit or less kpa Note 5) Minimum display: to 5ºC (No condensation) Equivalent to IP65 35 g Note ) The minimum supply vacuum pressure should be 3.3 kpa less than the maximum vacuum pressure setting value. Note ) 4 to ma is not possible with the -wire type. Power supply voltage (4 VDC or to 5 VDC) is required. Note 3) Value for the state with no over current circuit included. If an allowance is provided for an over current circuit, the input impedance varies depending on the input power supply. This is 35 or less for an input current of ma DC. Note 4) When the analogue output figure of to 5 VDC of ITV under the condition of the load impedance less than KΩ, the full span of the analogue output with ±6% or less may not be achieved. When ±6% or less (full span) is needed, please contact SMC. However there is no influence on the output pressure. Note 5) Please contact SMC regarding indication with other units of pressure. Note 6) For communication models, the maximum current consumption is.6 A or less. Note 7) For communication models, add roughly 8 g to the weight ( g for the PROFIBUS DP). Piping/Wiring Diagram Input signal (VDC, madc) VAC Vacuum pump, Ejector ITV9 Tank Set pressure (Vacuum) Flow Characteristics Series ITV9 Linearity Hysteresis Repeatability Output pressure [kpa] 4 6 Output deviation factor (% F.S.).5.5 Return Out Output deviation factor (% F.S.) Pressure Characteristics Output deviation factor (% F.S.) Input signal (% F.S.) Set point.5.5. Set pressure: kpa VAC. side pressure (Supply pressure) [kpa] Set pressure [kpa] Input signal (% F.S.) Count Flow Characteristics Supply vacuum pressure: kpa Flow characteristics measurement conditions Exhaust flow rate of the vacuum pump used for measurement: 5 l/min (ANR) Inlet vacuum pressure: kpa (When outlet flow rate is l/min (ANR)) Maximum flow rate: 3 l/min (ANR) (With inlet vacuum pressure at 39 kpa) 5 5 Flow rate [l /min(anr)]

27 Electronic Vacuum Regulator Series ITV9/9 5 Dimensions Note) Do not attempt to rotate the cable connector, as it does not turn. ITV9 Flat bracket.5 M x Connector (Plug type) M5 x.8 Breathing hole Rc /4 VAC. port 99 (53) () Flat bracket assembly KT-ITV-F (Option) VAC. (Vacuum pressure) x Rc /4 ATM. port, port 9 ATM. (Atmospheric pressure) (Set pressure).6 Flat bracket assembly KT-ITV-F (Option) 4 x M5 x.8 thread depth 6 mm through Right angle type (4-wire) Cable connector 3 m Straight type (4-wire) Cable connector 3 m (33) x ø7 Mounting hole 5 4 Note) Do not attempt to rotate the cable connector, as it does not turn. L-bracket 4 x R3.5 5 L-bracket assembly KT-ITV-L (Option) (8.5) L-bracket assembly KT-ITV-L (Option)

28 5 Series ITV9/9 Electronic Vacuum Regulator Dimensions 9 (CC-Link, DeviceNet, PROFIBUS DP and RS-3C) CC-Link/ITV9-CC M x Reverse connector M x 8.5 Rc /4 VAC port x Rc /4 ATM port, port (Vacuum pressure) ATM (6) (54).6 (Atmospheric pressure) PROFIBUS DP/ITV9-PR M x Communication cable connection thread M x Power cable connection thread 36 M reverse connector Communication cable connection thread.5.5 () 36 (Set pressure) M x Power cable connection thread () 9 DeviceNet /ITV9-DN 8.5 Rc /4 VAC port x Rc /4 ATM port, port 8.5 (Vacuum pressure) RS-3C/ITV9-RC ATM (Atmospheric pressure) M x Power cable connection thread M x Communication cable connection thread 36 6 (Set pressure).6 M x Power cable connection thread M x Communication cable connection thread () () Rc /4 VAC port 36 Rc /4 VAC port 6 9 x Rc /4 ATM port, port (Vacuum pressure) ATM (Atmospheric pressure) 36 (Set pressure).6 9 x Rc /4 ATM port, port (Vacuum pressure) ATM (Atmospheric pressure) 36 (Set pressure).6 With power cable connector CC ITV9- DN PR common dimensions RC Cable connector (4-wire) Right angle type Cable connector (4-wire) Straight type (33) Note) Do not attempt to rotate the cable connector, as it does not turn.

29 Electronic Vacuum Regulator Series ITV9/9 53 Precautions Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage. Further, use DC power with sufficient capacity and a low ripple. Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage. Further, use DC power with sufficient capacity and a low ripple. Brown Blue White Black Terminal No. 3 4 Lead wire colour Brown White Blue Black Wiring Power Signal COM Monitor : (White) 4: (Black) : (Brown) 3: (Blue) Wiring Diagrams Current signal type Brown Blue Vs White Black A Note) Vs: Power Supply 4 VDC ±% to 5 VDC A : Input signals 4 to ma DC to ma DC Monitor output wiring diagram Analogue output, voltage type Monitor output voltage Note) A right angle type cable is also available. The entry direction for the right angle type connector is to downwards (SUP port side). Never turn the connector as it is not designed to turn. Using force to turn the connector will damage the connector coupling. Voltage signal type Brown Blue Vs White Black Vin Body Vs : Power Supply 4 VDC ±% to 5 VDC Vin: Input signals to 5 VDC to VDC Brown Blue White Black Brown Blue White Black Body Note) Current Signal Type Voltage Signal Type Brown Power supply White Input signal 3 4 Blue Black GND (COMMON) Monitor output Communication connector DeviceNet Power RESET Communication connector Power supply connector PROFIBUS DP Communication connector Pin No IN/ communication connector DeviceNet DRAIN V+ V CAN_H CAN_L CC-Link SLD DB DG DA NC CC-Link DeviceNet, RS-3C 3: (Blue) : (Brown) 4: (Black) : (White) Preset Input Type Brown Power supply White Input signal Blue GND (COMMON) Black Input signal 4 3 Power supply connector Power supply connector PROFIBUS DP NC RxD/TxD-N NC RxD/TxD-P NC RS-3C NC TxD RxD GND NC Pin No. 3 4 CC-Link Vcc FG GND NC Power supply connector DeviceNet Vcc No connection GND No connection PROFIBUS DP Vcc NC GND NC RS-3C Vcc NC GND FG Note) The cable is also available in a right-angle type. A right-angle type connector is attached facing left (towards the SUP port). On communication models, the connector faces backwards (towards the EXH port). Do not attempt to rotate, as the connector does not turn. Trademark Information DeviceNet is a trademark of ODVA.

30 54 Series ITV9/9 Electronic Vacuum Regulator Precautions Wiring diagram Current signal type Brown Blue Vs White Black A Voltage signal type Brown Blue Vs White Black Vin Vs : Power supply A : Input signal 4 VDC to 5 VDC 4 to ma DC to ma DC Vs : Power supply 4 VDC to 5 VDC Vin: Input signal to 5 VDC to VDC Preset input type Brown Blue Vs S S White Black Vs : Power supply 4 VDC to 5 VDC One of the preset pressures P through P4 is selected by the ON/OFF combination of S and S. S S Preset pressure OFF OFF P ON OFF P OFF ON P3 ON ON P4 For safety reasons, it is recommended that one of the preset pressures be set to MPa. Preset pressures are set based on the minimum unit for output display. MPa. kgf/cm. bar. Monitor output wiring diagram Analogue output: Voltage type psi. Note that this is psi for 3-psi types. Brown kpa Analogue output: Current type (Sink type) Brown Blue Blue Monitor output voltage White Black Monitor output voltage White Black Switch output: NPN type Switch output: PNP type Brown Blue Load Blue White Black Load Brown White Black When 3 ma DC or more is applied, detecting device for overcurrentstarts activating and then emits an error signal. (Error number 5 )

31 Booster Regulator / Tank Series VBA/VBAT 55 Booster Regulator / Tank Series VBA / VBAT RoHS Features Noise reduced. Built-in mesh filter at IN port. Boosted up to MPa VBAA, VBAA. Pressure increase ratio of. How to Order VBA A A 4A A 4A 43A A /4", Handle-operated type 3/8", Handle-operated type /", Handle-operated type 3/8", -operated type /", -operated type /", Max. operating pressure.6 MPa /4", Handle-operated type How to Order VBAT VBA 4A F 4 Body size Pressure increase ratio: Twice Pressure increase ratio: to 4 times Thread type Note) F G Note) Thread types apply to the IN,, and EXH ports of the VBAA and to the IN,, EXH, and gauge ports of the VBAA and VBA4A. The gauge ports of the VBAA are Rc thread type regardless of the thread type indication. VBAT A F 5 38 Tank internal capacity Internal capacity 5 L L L 38 L Material Material A Carbon steel (SS4) Option Option - None G Pressure gauge N Silencer S High-noise reduction silencer GN Pressure gauge, Silencer GS Pressure gauge, High-noise reduction silencer Port size Port size Applicable series 3 4 /4 3/8 / VBAA VBAA VBA4A SV Thread type F G Q CE certified product (Self-declaration document attached) Accessories Accessories Safety valve (Set pressure: MPa) RV Drain valve Safety valve (Set pressure: MPa) SV Drain valve Applicable model VBATA VBAT38A VBAT5A VBATA Product Recommendation Stocked items for fast delivery VBAA-F VBAA-FGN VBAA-F VBAA-FGN VBAA-F3 VBAA-F3GN VBAA-F3GN VBA4A-F4 VBA4A-F4GN VBA43A-F4 VBA43A-F4GS Accessories and Related Products (Accessories) Series G - Pressure Gauge - Series AN - Silencer- page 556 (Related Products) Series TU - Tubing - page 3 Series KQ - Fittings - page 84 Series AF - Filter - page 8 Series AM - Mist Separator - page 7 Series AMC - Exhaust Cleaner -

32 56 Series VBA/VBAT Booster Regulator / Tank Specifications VBA Model Fluid Pressure increase ratio Pressure adjustment mechanism Max. flow rate Note ) [L/min (ANR)] Set pressure range [MPa] Supply pressure range [MPa] Proof pressure [MPa] Port size (IN//EXH: 3 locations) Accessories VBA VBAA- VBAA-3 VBA4A-4 VBAA-3 VBA4A-4 VBA43A-4 VBAA- Compressed air Twice to 4 times Handle-operated with relief mechanism Note ) -operated 3. to. 3 G/4 Handle-operated with relief mechanism Note ) to.. to.. to.6. to.. to G3/8 G/ G3/8 G/ Pressure gauge port size (IN/: locations) Rc/8 G/8 Ambient and fluid temperature [ C] to 5 (No freezing) Installation Horizontal Lubrication Grease (Non-lube) Weight [kg] Note ) If the pressure is higher than the set pressure by the handle, excess pressure is exhausted from the back of the handle. Note ) Flow rate at IN= =.5 MPa. The pressure varies depending on the operating conditions. Refer to Flow-rate Characteristics. G/4 Rc/8.89 Pressure Gauge, Silencer (When thread type is G.) Model VBAA- VBAA-3 VBA4A-4 Description VBAA-F VBAA-F3 VBA4A-F4 Pressure gauge G G7-- G36-- Silencer N AN- AN3-3 AN4-4 VBAA-3 VBAA-F3 KT-VBAA-7 AN3-3 VBA4A-4 VBA4A-F4 G36-- AN4-4 High-noise reduction silencer S ANA- ANA-3 ANA-4 ANA-3 ANA-4 Note ) In the case of options GN, two pressure gauges and one silencer are included in the same container as accessories. Note ) KT-VBAA-7 is a pressure gauge with fitting. (Please order two units when using with IN and.) VBA43A-4 VBA43A-F4 G7-- AN4-4 ANA-4 VBAA- VBAA-F G7-- AN- ANA- Specifications VBAT Model VBAT5A -SV-Q VBATA -SV-Q VBATA -RV-Q VBAT38A -RV-Q Fluid Compressed air Tank capacity [L] 5 38 Max. operating pressure [MPa].. IN port size port size 3/8 3/8 / / 3/4 / 3/4 3/4 Ambient and fluid temperature [ C] to 75 Weight [kg] Material Paint Carbon steel (SS4) Outside: Silver paint, Inside: Rustproof paint Note) The accessories and options are included in the same container. Accessories VBAT Model VBAT5A-SV-Q VBATA-SV-Q VBATA-RV-Q VBAT38A-RV-Q Accessory kit VBAT5A-Y- VBATA-Y- VBATA-Y- Safety valve VBAT-S (Set pressure: MPa) VBAT-R (Set pressure: MPa) Drain valve VBAT-V Safety valve Drain valve VBAT-V IN PORT /4 Safety valve VBAT-R, VBAT-S ø8.5 Drain valve 58 (CLOSE) to 63 (OPEN) ø3 9 PORT /8 5 3/8 65 (width across flats)

33 Booster Regulator / Tank Series VBA/VBAT 57 Flow Characteristics VBAA Flow-rate Characteristics VBAA, A Flow-rate Characteristics. VBA4A, 4A Flow-rate Characteristics. Outlet pressure [MPa].5.5 P =. MPa P =.75 MPa P =.5 MPa P =.4 MPa P =.3 MPa P = P Outlet pressure [MPa] P =.3 MPa P =.5 MPa P =.4 MPa Outlet pressure [MPa] P =.5 MPa P =.4 MPa P =.3 MPa. 3 4 Outlet air flow rate [L/min (ANR)] Pressure Characteristics Inlet pressure:.7 MPa Outlet pressure:. MPa Flow rate: L/min (ANR) (Representative value) Outlet air flow rate [L/min (ANR)] Pressure Characteristics Inlet pressure:.7 MPa Outlet pressure:. MPa Flow rate: L/min (ANR) (Representative value) Outlet air flow rate [L/min (ANR)] Pressure Characteristics Inlet pressure:.7 MPa Outlet pressure:. MPa Flow rate: L/min (ANR) (Representative value).5 Set point. Set point. Set point Outlet pressure [MPa] Outlet pressure [MPa] Outlet pressure [MPa] Inlet pressure [MPa] Inlet pressure [MPa] Inlet pressure [MPa] Charge Characteristics Charge time per L t [s] Pressure increase ratio P/P Charge Characteristics Charge time per L t [s] Pressure increase ratio P/P VBAA VBAA, A The time required to charge pressure in the The time required to charge pressure in the tank from.7 MPa to.95 MPa at.5 MPa tank from.8 MPa to. MPa at.5 MPa supply pressure: supply pressure: P.7 P.95 P.8 P. = =.4 = =.9 = =.6 = P.5 P.5 P.5 P.5 =. With the pressure increase ratio from.4 to.9, the charge time of 3 6 = 7 sec. (t) is given by the graph. Then, the charge time (T) for a L tank: V T = t x = 7 x = 7 (s). With the pressure increase ratio from.6 to., the charge time of = 7.7 sec. (t) is given by the graph. Then, the charge time (T) for a L tank: V T = t x = 7.7 x = 77 (s). Charge Characteristics Charge time per L t [s] Pressure increase ratio P/P VBA4A, 4A The time required to charge pressure in the tank from.8 MPa to. MPa at.5 MPa supply pressure: P.8 P. = =.6 = =. P.5 P.5 With the pressure increase ratio from.6 to., the charge time of 3.5. =.4 sec. (t) is given by the graph. Then, the charge time (T) for a L tank: V T = t x =.4 x = 4 (s).

34 58 Series VBA/VBAT Booster Regulator / Tank Flow Characteristics VBA43A Flow-rate Characteristics VBAA Flow-rate Characteristics Pulsation/Pulsation is decreased with a tank. If the outlet capacity is undersized, pulsation may occur..6.4 VBAT5A. Outlet pressure [MPa] Outlet air flow rate [L/min (ANR)] Pressure Characteristics P =.8 MPa P =.7 MPa P =.6 MPa P =.5 MPa P = P Inlet pressure:.7 MPa Outlet pressure:. MPa Flow rate: L/min (ANR) (Representative value) Outlet pressure [MPa]. P =.3 MPa 5 5 Outlet air flow rate [L/min (ANR)] Pressure Characteristics P =.4 MPa P =.5 MPa P =.75 MPa Inlet pressure:.6 MPa Outlet pressure:. MPa Flow rate: L/min (ANR) P =. MPa P = P (Representative value) Max. pulsation range [MPa] Capacity [L] VBAT VBAT5A Outlet pressure [MPa] Charge time per L t [s] Set point Inlet pressure [MPa] Charge Characteristics Pressure increase ratio P/P VBA43A The time required to charge pressure in the tank from.8 MPa to. MPa at.5 MPa supply pressure: P.8 P. = =.6 = =. P.5 P.5 With the pressure increase ratio from.6 to., the charge time of = 3. sec. (t) is given by the graph. Then, the charge time (T) for a L tank: Outlet pressure [MPa] Charge time per L t [s] Set point Inlet pressure [MPa] Charge Characteristics Pressure increase ratio P/P VBAA The time required to charge pressure in the tank from. MPa to.5 MPa at.5 MPa supply pressure: P. P.5 = =. = = 3. P.5 P.5 With the pressure increase ratio from. to 3., the charge time of = 89 sec. (t) is given by the graph. Then, the charge time (T) for a L tank: Max. pulsation range [MPa] VBAA VBATA, A, 38A VBATA Capacity [L] VBAA VBA4A Conditions: Inlet pressure:.5 MPa Outlet set pressure: MPa Flow rate: Between and max. flow rate VBATA VBAT38A VBAT Performance of air tank Alleviates the pulsation generated on the outlet side. When air consumption exceeds air supply during intermittent operation, required air will be accumulated in the tank for use. This does not apply for continuous operation. V T = t x = 3. x = 3 (s). V T = t x = 89 x = 89 (s).

35 Booster Regulator / Tank Series VBA/VBAT 59 Dimensions 3 VBAA- 3 7 IN port /4 port /4 7 8 Silencer (Option) IN side gauge port Rc /8 5 6 Pressure gauge (Option) side gauge port Rc /8 4 x ø EXH port /4 (When silencer installed: 7) (When high-noise reduction silencer installed: 6) VBAA- 3 7 IN port /4 port /4 7 8 Silencer (Option) IN side gauge port Rc / Pressure gauge (Option) side gauge port Rc /8 4 x ø5.5 VBAA-3 6 EXH port 7 /4 (When silencer installed: 7) (When high-noise reduction silencer installed: 6) Pressure gauge (Option) 76 IN port 3/8 IN side gauge port /8 side gauge port /8 43 port 3/8 5 Silencer (Option) x ø VBA4A-4 98 EXH port 8 3/8 (When silencer installed: 6) (When high-noise reduction silencer installed: 79) 43 IN side gauge port / Pressure gauge (Option) side gauge port / IN port / port / 8 Silencer (Option) 3 4 x ø 3 EXH port 5 / (When silencer installed: 6) (When high-noise reduction silencer installed: 3)

36 6 Series VBA/VBAT Booster Regulator / Tank Dimensions Pressure gauge (Option) VBAA-3 IN side gauge port /8 side gauge port / IN port 3/8 port 3/8 5 Silencer (Option) 4 4 x ø 98 8 EXH port 3/8 (When silencer installed: 6) (When high-noise reduction silencer installed: 79) VBA4A-4 43 IN side gauge port / Pressure gauge (Option) side gauge port /8 IN port Rc / port Rc / 8 Silencer (Option) 3 4 x ø VBA43A EXH port / (When silencer installed: 4) (When high-noise reduction silencer installed: 6) 43 IN side gauge port / Pressure gauge (Option) side gauge port / IN port / port / 8 Silencer (Option) 3 4 x ø 3 5 EXH port / (When silencer installed: 6) (When high-noise reduction silencer installed: 3)

37 Booster Regulator / Tank Series VBA/VBAT 6 Dimensions VBAT5A-Q Material: Carbon steel Connected to VBAA, A Booster regulator IN port /4 EXH: /4 Safety valve port 3/8 Tank IN port 3/8 Spare port x / (37) (37) ø56 4 x ø Tank port 3/ Drain port / The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences. VBATA-Q Connected to VBAA, A Material: Carbon steel Booster regulator IN port /4 EXH: /4 Safety valve port 3/8 Tank IN port / Spare port x / (39) (38) ø8 8 4 x ø Tank port / Drain port / The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences. Connected to VBAA Booster regulator IN port 3/8 EXH: 3/8 Safety valve port 3/8 Tank IN port / Spare port x / Connected to VBAA Booster regulator IN port 3/8 EXH: 3/8 (454) (367) ø8 4 x ø Tank port / (47) (367) ø8 4 x ø The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences. Drain port /4 8 When option G (pressure gauge) is selected

38 6 Series VBA/VBAT Booster Regulator / Tank Specifications Dimensions: CE Certified Product VBATA-Q Material: Carbon steel Connected to VBAA, 4A Booster regulator IN port C Tank IN port 3/4 Safety valve port 3/8 Connected to VBAA, 4A Booster regulator IN port C (A) (B) ø6 EXH: C 4 x ø Tank port / The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences. 5 5 Drain port / Spare port x / (A) (B) Booster regulator model VBAA VBA4A VBAA VBA4A ø6 A B C 3/8 / 3/8 / EXH: C Note) When option G (pressure gauge) is selected D 4 x ø3 [mm] D Note) (A) VBAT38A-Q Material: Carbon steel Connected to VBAA, 4A (B) Booster regulator IN port C EXH: C Tank IN port 3/4 Safety valve port 3/8 5 Spare port x / (A) (B) Connected to VBAA, 4A Booster regulator IN port C EXH: C D ø x ø3 5 Tank port 3/4 Drain port /4 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences Booster regulator model VBAA VBA4A VBAA VBA4A ø56 A B C 3/8 / 3/8 / Note) When option G (pressure gauge) is selected 4 x ø3 [mm] D Note)

39 Refrigerated Dryer Serie IDFAE, IDFAF 63 Refrigerated Dryer Series IDFAE, IDFAF Features Secondary heater introduction (IDFAF). Easy maintenance. Space saving. High corrosion-resistant. Wide range of air dryer sizes. Montreal protocol compliant. How to Order IDFA 8 E Size Voltage Voltage 3 Single-phase 3 VAC (5 Hz) Note ) Options A C K L V None Cool compressed air output Anti.corrosive treatment For.6 MPa application (Auto drain bowl type: metal bowl with level gauge) With heavy duty auto drain (applicable to.6 MPa) With timer-type solenois valve (applicable to.6 MPa) Note) Refer to table below Options and Available Combinations (Size/Option) Size (option) Note ) A C K L V Note ) Thread adapters to convert Rc thread to R thread are included with IDFA3E to IDFA5E. Note ) Enter alphabetically when multiple options are combined. However, the following combination cannot be achieved. Combination of K,L and V cannot be achieved bacause on auto switch drain can only be attached to a single option IDFA F 4 Size 5 5 Voltage Voltage 4 Three-phase 4 VAC (5 Hz) Option Note) Description - None C Anti-corrosive treatment for copper tube K Moderate pressure specification (.6 MPa) R With a circuit breaker V With a timer controlled solenoid valve type auto drain. Note) Enter alphabetically when multiple options are combined. Product Recommendation Related Products Stocked items for fast delivery IDFA3E-3 IDFA3E-3-A IDFA4E-3 IDFA6E-3 IDFA6E-3-K IDFA8E-3 IDFA8E-3-K IDFAE-3 IDFAE-3-K IDFA5E-3 IDFA5E-3-K IDFAE-3-K IDFA37E-3 IDFA37E-3-K IDFA55E-3-L IDFA75E-3-L IDFAF-4 IDFA5F-4 IDFA5F-4 Series AC - - page 76 Series TU - Tubing - page 3 Series KQ - Fittings - page 84 Series PFA - Digital Flow Swith for - page 39 Series ZSE/ISEA - Digital Pressure Switch for - page 73 Series VNB - Port Operated Valves - page 466 Series VXZ - Pilot Operated Port Solenoid Valves - page 45

40 64 Serie IDFAE, IDFAF Refrigerated Dryer Specifications Specifications Fluid Inlet air temperature Inlet air pressure Ambient temperature (Humidity) Operating range Note 3) Electric Rated specifications flow capacity m 3 /h Note ) Standard condition (ANR) Note ) Compressor intake condition Inlet air pressure Inlet air temperature Ambient temperature Power supply voltage Power consumption Operating current Note 4) Applicable circuit breaker capacity Condenser Refrigerant Auto drain Port size Accessory Weight Coating colour Compliant standards Model Standard temperature air inlet IDFA3E IDFA4E IDFA6E IDFA8E IDFAE IDFA5E Compressed air [ºC] 5 to 5 [MPa].5 to. [ºC] to 4 (Relative humidity of 85% or less) [3ºC) [7ºC) [ºC] [3ºC] [7ºC] [ºC] [MPa].7 [ºC] 35 [ºC] 5 Single-phase: 3 VAC [Voltage fluctuation ±%] 5 Hz [W] 8 [A]. [A] [kg] Float type (Normally closed) Rc 3/8 Rc / cooled R34a (HFC) Float type (Normally open) Rc 3/4 Rc Hexagon nipple Body panel: White Base: Grey EC Directive (with CE marking) Note ) flow capacity under the standard condition (ANR) [atmospheric pressure at ºC, relative humidity at 65%] Note ) flow capacity converted by the compressor intake condition [atmospheric pressure at 3ºC] Note 3) Select air dryer according to the model selection method for the models beyond the rated specifications. Note 4) Install a circuit breaker with a sensitivity of 3 ma. Note 5) When a short-term interruption of the power supply (including momentary interruption) occurs in this equipment, the restarting of normal operations may require some time or may be impossible due to the operation of protective devices even after the supply of power returns. Replacement Parts Model IDFA3E Auto drain replacement parts no. Note 6) IDFA4E AD38 IDFA6E Note 6) The part number for the auto drain components without including the body part. Body part replacement is impossible. IDFA8E IDFAE IDFA5E AD48 Body Auto drain

41 Refrigerated Dryer Serie IDFAE, IDFAF 65 Specifications Model Standard temperature air inlet Specifications IDFAE IDFA37E IDFA55E IDFA75E Fluid Inlet air temperature Inlet air pressure Ambient temperature (Humidity) [ºC] [MPa] [ºC] Compressed air 5 to 5.5 to. to 4 (Relative humidity of 85% or less) Note ) Standard condition Outlet air pressure dew point Outlet air pressure dew point [3ºC) [7ºC) flow (ANR) Outlet air pressure dew point [ºC] capacity Note ) m 3 /h Compressor Outlet air pressure dew point [3ºC] intake Outlet air pressure dew point [7ºC] condition Outlet air pressure dew point [ºC] Inlet air pressure Inlet air temperature Ambient temperature Power supply voltage [MPa] [ºC] [ºC] Single-phase: 3 VAC [Voltage fluctuation ±%] 5 Hz Power consumption Operating current [W] [A] Applicable circuit breaker capacity Note 4) Condenser Refrigerant Auto drain [A] -cooled R47C (HFC) Float type (Normally open) Port size R R / R Accessory Weight [kg] Coating colour Compliant standards Body panel: White Base: Gray EC Directive (with CE marking) Operating range Note 3) Electric Rated specifications Note ) flow capacity under the standard condition (ANR) [atmospheric pressure at ºC, relative humidity at 65%] Note ) flow capacity converted by the compressor intake condition [atmospheric pressure at 3ºC] Note 3) Select air dryer according to the model selection method (page ) for the models beyond the rated specifications. Note 4) Install a circuit breaker with a sensitivity of 3 ma. Note 5) When a short-term interruption of the power supply (including momentary interruption) occurs in this equipment, the restarting of normal operations may require some time or may be impossible due to the operation of protective devices even after the supply of power returns. Replacement Parts Model Auto drain replacement parts no. Note 6) AD48 IDFAE IDFA37E IDFA55E IDFA75E Note 6) The part number for the auto drain components without including the body part. Body part replacement is impossible. Body Auto drain

42 66 Serie IDFAE, IDFAF Refrigerated Dryer Specifications Specifications Fluid Inlet air temperature Inlet air pressure Operating range Note 3) Rated conditions Electric specifications [ C] [MPa] Ambient temperature (humidity) [ C] Standard condition flow capacity m 3 /h condition Inlet air pressure Inlet air temperature Ambient temperature Outlet air pressure dew point Power supply voltage Power consumption Operating current Applicable circuit breaker capacity Note 4) Heat discharge from condenser Refrigerant Auto drain Port size Weight Coating colour Compliant standards Model (ANR) Note ) Compressor intake Note ) [MPa] [ C] [ C] [ C] [kw] [A] [A] [kw] [kg] IDFAF-4 IDFA5F-4 IDFA5F-4 Compressed air 5 to 6.5 to. (.5 to.6 for option K) to 45 (Relative humidity 85% or less) Three-phase 4 VAC R47C (HFC) Float type (Normally open) The option V stands for a timer type solenoid valve. R R / DIN flange Body panel: White Base: Grey EC Directive compliant (with CE marking) Note ) flow capacity under the standard condition (ANR) [atmospheric pressure C, relative humidity 65%] Note ) flow capacity converted by the compressor intake condition [atmospheric pressure 3 C] Note 3) The operation range does not guarantee the use with normal air flow capacity. When operating conditions are different from the rated specifications, please select a model in accordance with Model Selection. Note 4) Install a circuit breaker with a sensitivity 3 ma. Replacement Parts dryer model Heavy duty auto drain replacement part no. Note 5) Dustproof filter set for condenser IDFAF IDFA5F ADH-E4 IDF-FL9 Note 5) Part number of only the exhaust mechanism replacement kit excluding the housing IDFA5F IDF-FL Exhaust mechanism replacement kit Housing (Use existing equipment.)

43 Refrigerated Dryer Serie IDFAE, IDFAF 67 Optional Accessories Dust-protecting filter set Note) Features Prevents a reduction in the performance of the air dryer, even in dusty atmospheres. Specifications Max. ambient temperature 4ºC Applicable dryer IDFA3E to 75E Pre-filter Prevents dust to enter air dryer. Extended life of dryer. Filtration rate 3μm IDFA3E to 75E Foundation bolt set For fixing the air dryer to the foundations. Easy to secure by striking the axle. Stainless steeel IDFA4E to 75E Note) Standard for IDFAF/5F/5F. How to Order Dust-protecting filter set IDF FL 9 Foundation bolt set IDF AB 5 Applicable dryer Applicable dryer 9 IDFA3E IDFA4E 3 IDFA6E 4 IDFA8E 5 IDFAE 6 IDFA5E 7 IDFAE Applicable dryer IDFA37E IDFA55E IDFA75E Applicable dryer Applicable dryer 5 IDFA4E to 75E 5 IDFAF to 5F Dust-protecting Filter Set / Dimensions () A () B () Dimensions [mm] Part no. Applicable dryer A B Weight [g] IDF-FL9 IDFA3E 4 35 IDF-FL IDFA4E IDF-FL3 IDFA6E IDF-FL4 IDFA8E IDF-FL5 IDFAE IDF-FL6 IDF-FL7 IDF-FL8 IDF-FL3 IDF-FL4 IDFA5E IDFAE IDFA37E IDFA55E IDFA75E (IDF-FL9) (IDF-FL to 8, 3, 4) Foundation Bolt Set / Dimensions Dustproof filter Dimensions [mm] Part no. Applicable dryer A B IDF-FL9 IDFAF IDFA5F IDF-FL IDFA5F Electrical equipment 5 Dimensions Part no. IDF-AB5 IDF-AB5 Applicable dryer IDFA4E to 75E IDFAF to 5F Nominal thread size M M Material Stainless steel Stainless steel [mm] Pcs. of set 4 4 Mounting hole diameter: ø.5

44 68 Serie IDFAE, IDFAF Refrigerated Dryer Data Condensed Water Calculation 8% Relative humidity % B 6% 4% % Amount of water in air [g /m 3 ] Amount of condensed water C H = 5. g/m 3 C Atmospheric pressure. MPa..3.4 D H G A F E Ambient temperature ( compressor intake air temperature) [ºC] Pressure dew point [ºC] Dew Point Conversion Chart Pressure dew point [ºC] A B.5 MPa.3 MPa. MPa -.9 MPa -.7 MPa.5 MPa -3.3 MPa. MPa -4 Atmospheric -5 pressure C Atmospheric pressure dew point [ºC] How to read the dew point conversion chart Example) To obtain the atmospheric pressure dew point at a pressure dew point ºC and a pressure.7 MPa.. Trace the arrow mark starting from the point A at a pressure dew point ºC to obtain the intersection B on the pressure characteristic line for.7 MPa.. Trace the arrow mark starting from the point B to obtain the intersection C at the dew point under atmospheric pressure. 3. The intersection C is the conversion value 7ºC under atmospheric pressure dew point. How to calculate the amount of condensed water Example) To obtain the amount of condensed water when the pressure is applied to air up to.7 MPa with an air compressor, then cooled down to 5ºC. Given an ambient temperature at 3ºC and a relative humidity 6%.. Trace the arrow mark from the point A at an ambient temperature 3ºC to obtain the intersection B on the curved line for the relative humidity 6%.. Trace the arrow mark from the intersection B to obtain the intersection D on the pressure characteristic line for.7 MPa. 3. Trace the arrow mark from the intersection D to obtain the intersection E. 4. The intersection E is the dew point under pressure.7 MPa with an ambient temperature 3ºC and a relative humidity 6%. The value for E is 6ºC. 5. Trace the intersection E upward, and trace from the intersection D leftward to obtain the intersection C. 6. The intersection C is the amount of moisture included in the compressed air m 3 at.7 MPa and a pressure dew point 6ºC. The amount of moisture is 8. g/m Trace the arrow mark, starting from F for cooling temperature 5ºC (pressure dew point 5ºC) to obtain the intersection G on the pressure characteristic line for.7 MPa. 8. From the intersection G, trace the arrow mark to obtain the intersection H on the vertical axis. 9. The intersection H is the amount of moisture included in the compressed air m 3 at.7 MPa, and a pressure dew point 5ºC. The amount of moisture is 3. g/m 3.. Therefore, the amount of condensed water is as follows (per m 3 ): The amount of moisture at the intersection C the amount of moisture at the intersection H = the amount of condensed water = 5. g/m 3

45 Refrigerated Dryer Serie IDFAE, IDFAF 69 Dimensions IDFA3E to 5E A Outlet E D Inlet C F G In case of IDFA3E A Q B E Inlet D Outlet C M F G L P K 4 x ø3 N IDFA4E to E A Q B Inlet E Outlet D C M F G L P K 4 x ø3 N In case of IDFA5E Dimensions Model Port size IDFA3E Rc 3/8 IDFA4E Rc / IDFA6E IDFA8E Rc 3/4 IDFAE IDFA5E Rc A [mm] B C D E F G K L M N P Q Meaning the foot dimensions for the IDFA3E

46 7 Serie IDFAE, IDFAF Refrigerated Dryer Dimensions IDFAE, IDFA37E D B E G A F C M N P L K 4 x ø3 Dimensions Model Port size IDFAE R IDFA37E R / A 9 [mm] B C D E F G K L M N P Q IDFA55E, IDFA75E B R A Q E D G C F M P L N K 4 x ø3 Dimensions Model Port size IDFA55E R IDFA75E A B C D E F G K L M N P Q 8 (868) (8) (73) () () 9 (968) [mm] R 59

47 F C Refrigerated Dryer Serie IDFAE, IDFAF 7 Dimensions IDFAF/5F/5F IDFAF/5F B E D G A F C M L N P K Dimensions Model IDFAF IDFA5F Port size R R / A 67 7 B 3 C 76 D 67 E F 375 G K L 7 M 7 78 N [mm] P 75 IDFA5F B E D G A P L K N M Dimensions Model IDFA5F Port size DIN flange 8 A 95 B 3 C 33 D 68 E 7 F 43 G 475 K L 99 M 7 N 935 [mm] P 3

48 7 Series IDG Membrane Dryer Membrane Dryer Series IDG RoHS Features Energy saving design. Compatible with low dew points: -5ºC, -ºC, -4ºC, -6ºC. Power supply is not required. Non-fluorocarbon. Dew point indicator visually confirms air drying. How to Order IDG IDG IDG 3 5 Size F 3 Option Contents Size None (Standard) P With fitting for purge air discharge R Flow direction (Right Left) S With dew point indicator 5 Standard equipment Note) In the case of two or more options, indicate them alphabetically IDG3 Thread type F G Accesory B Type None (Standard) With bracket (except IDG) Port size Bore Size /8 /4 3 3/8 4 / A Sizes, 3, 5,,, 6 (Standard, H), 75 (Standard, H), (Standard, H) 3, 5, 6 (L, S), 75 (L, S), (L, S) Standard dew point and air flow rate Dew Point Flow rate by size outlet ir flow rate [l/min (ANR)] H - C standard -5 C high dewpoint L S -4 C low dewpoint -6 C super low dewpoint Product Recommendation IDG-F IDG-F-P IDG3-F-S IDG5-F IDG5-F-S IDG5-F IDG5-F-S IDG5H-F Stocked items for fast delivery IDG5H-F-S IDG-F IDG-F3 IDG-F3-R IDGH-F IDG-F IDG-F3 IDG3A-F3 IDG3LA-F3 IDG5A-F3 IDG5LA-F3 IDG6-F4 IDG75-F4 IDG-F4 Also Available The IDG can be combined with SMC standard modular filters and regulators. For details on how to order complete assemblies, please contact SMC. Bracket Assembly (Accessory) Part No. Part no. Applicable model BM59 IDG3, 5 BM6 IDG BM63 IDG BM64 IDG3A/5A BM65 IDG6/75/ With cap bolts and spring washers Related Products Series AC - - page 76 Series TU - Tubing - page 3 Series KQ - Fittings - page 84 Series PFA - Digital Flow Switch for - page 39 Series IS - Pressure Switch for - page 93 Series ZSE/ISEA - Digital Pressure Switch for - page 73 Note) For replacement elements and dew point indicators, please contact SMC.

49 Membrane Dryer Series IDG 73 Specifications Standard Specifications/Single Style (Standard Dew Point C) Model Standard dew point C IDG IDG3 IDG5 IDG IDG IDG3A IDG5A IDG6 IDG75 IDG Fluid Compressed air Inlet air pressure [MPa].3 to.85.3 to. Inlet air temperature [ C] Note ) 5 to 55 5 to 5 Ambient temperature [ C] 5 to 55 5 to 5 Range of operating conditions Standard performance Standard performance conditions Outlet air atmospheric pressure dew point [ C] Inlet air flow rate [l/min] (ANR) Note ) Outlet air flow rate [l/min] (ANR) Purge air flow rate [l/min] (ANR) Note 3) Inlet air pressure MPa Inlet air temperature [ C] Inlet air saturation temperature [ C] Ambient temperature [ C] Dew point indicator purge air flow rate Port size (nominal size B) Weight [kg] (with bracket) l/min (ANR) {inlet air pressure at.7mpa} /4 /8, /4 /4, 3/8 3/8, / /..5 (.3).43 (.5).66 (.76).78 (.9).8 (.94).5 (.65).5 (.65).55 (.7) Note ) With no freezing. Note ) ANR indicates the flow rate converted to the value for C at atmospheric pressure. Note 3) Includes dew point indicator purge air flow rate of l/min (ANR) (inlet air pressure at.7mpa) (except IDG, IDG3 and IDG5 ). Standard Specifications/Single Style (Standard Dew Point 5 C) Model Standard dew point 5 C IDG3H IDG5H IDGH IDGH IDG3HA IDG5HA IDG6H IDG75H IDGH Fluid Compressed air Inlet air pressure [MPa].3 to.85.3 to. Inlet air temperature [ C] Note ) 5 to 55 5 to 5 Ambient temperature [ C] 5 to 55 5 to 5 Range of operating conditions Standard performance Standard performance conditions Outlet air atmospheric pressure dew point [ C] Inlet air flow rate [l/min] (ANR) Note ) Outlet air flow rate [l/min] (ANR) Purge air flow rate [l/min] (ANR) Note 3) Inlet air pressure [MPa] Inlet air temperature [ C] Inlet air saturation temperature [ C] Ambient temperature [ C] Dew point indicator purge air flow rate Port size (nominal size B) Weight [kg] (with bracket) l/min (ANR) {inlet air pressure at.7mpa} /8, /4 /4, 3/8 3/8, / /.5 (.3).43 (.5).66 (.76).78 (.9).8 (.94).5 (.65).5 (.65) Note ) With no freezing. Note ) ANR indicates the flow rate converted to the value for C at atmospheric pressure. Note 3) Includes dew point indicator purge air flow rate of l/min (ANR) (inlet air pressure at.7mpa) (except IDG3H and IDG5H)..55 (.7)

50 74 Series IDG Membrane Dryer Specifications Standard Specifications/Single Style (Standard Dew Point 4 C) Model Standard dew point 4 C IDG3LA IDG5LA IDG6LA IDG75LA IDGLA Fluid Compressed air Inlet air pressure [MPa].3 to. Inlet air temperature [ C] Note) 5 to 5 Ambient temperature [ C] Note) 5 to 5 Range of operating conditions Standard performance Standard performance conditions Outlet air atmospheric pressure dew point [ C] Inlet air flow rate [l/min] (ANR) Note ) Outlet air flow rate [l/min] (ANR) Purge air flow rate [l/min] (ANR) Note 3) Inlet air pressure [MPa] Inlet air temperature [ C] Inlet air saturation temperature [ C] Ambient temperature [ C] Dew point indicator purge air flow rate Port size (nominal size B) Weight [kg] (with bracket) (.9) l/min (ANR) {inlet air pressure at.7mpa} /4, 3/8 3/8, /.8 (.94).56 (.7).69 (.84).8 (.97) Note ) When using the product in the temperature range between 5 C and 5 C, prevent water droplets from entering the inlet port. (No freezing of the fluid) Note ) ANR indicates the flow rate converted to the value for C at atmospheric pressure. Note 3) Includes dew point indicator purge air flow rate of l/min (ANR) (inlet air pressure at.7mpa). Standard Specifications/Single Style (Standard Dew Point 6 C) Standard dew point 6 C Model IDG6SA IDG75SA IDGSA Fluid Compressed air Inlet air pressure [MPa].3 to. Inlet air temperature [ C] Note) 5 to 5 Ambient temperature [ C] Note) 5 to 5 Range of operating conditions Standard performance Standard performance conditions Outlet air atmospheric pressure dew point [ C] Inlet air flow rate [l/min] (ANR) Note ) Outlet air flow rate [l/min] (ANR) Purge air flow rate [l/min] (ANR) Note 3) Inlet air pressure [MPa] Inlet air temperature [ C] Inlet air saturation temperature [ C] Ambient temperature [ C] Dew point indicator purge air flow rate Port size (nominal size B) Weight [kg] (with bracket).56 (.7) l/min (ANR) {inlet air pressure at.7mpa} 3/8, /.69 (.84).8 (.97) Note ) When using the product in the temperature range between 5 C and 5 C, prevent water droplets from entering the inlet port. (No freezing of the fluid) Note ) ANR indicates the flow rate converted to the value for C at atmospheric pressure. Note 3) Includes dew point indicator purge air flow rate of l/min (ANR) (inlet air pressure at.7mpa).

51 Membrane Dryer Series IDG 75 Performance Charts Conditions: Inlet air temperature 5 C (saturated air), Ambient temperature 5 C, P: Inlet air pressure, Tube for purge air discharge (Option: P): None Note: Correcting outlet air flow rate is required depending on inlet air temperature. For model with fitting for purge air discharge (Option: P), the outlet air atmospheric pressure dew point may become higher depending on the tube length for purge air discharge. For other models, if the tube length is 5 m or less, a rise of the outlet air at the atmospheric pressure dew point will be C or less. Standard dew point C [: Nil], 5 C [: H] IDG IDG3, 3H Outlet air atmospheric pressure dew point [ C] P =.3 MPa P =.5 MPa P =.7 MPa 3 IDG Outlet air flow rate [l/min [ANR]] Outlet air atmospheric pressure dew point [ C] P =.3 MPa P =.5 MPa P =.7 MPa IDG3 3 IDG3H Outlet air flow rate [l/min [ANR]] IDG5, 5H IDG, H Outlet air atmospheric pressure dew point [ C] P =.3 MPa P =.5 MPa P =.7 MPa IDG5 3 IDG5H Outlet air flow rate [l/min [ANR]] Outlet air atmospheric pressure dew point [ C] P =.3 MPa P =.5 MPa P =.7 MPa IDG 3 IDGH Outlet air flow rate [l/min [ANR]] IDG, H Outlet air atmospheric pressure dew point [ C] P =.3 MPa P =.5 MPa P =.7 MPa IDG 3 IDGH 4 3 Outlet air flow rate [l/min [ANR]] IDG3A, 3HA Outlet air atmospheric pressure dew point [ C] P =.3 MPa P =.5 MPa P =.7 MPa 3 IDG3A 4 IDG3HA Outlet air flow rate [l/min [ANR]] IDG5A, 5HA IDG6, 6H Outlet air atmospheric pressure dew point [ C] P =.3 MPa P =.5 MPa P =.7 MPa 3 IDG5A 4 5 IDG5HA Outlet air flow rate [l/min [ANR]] Outlet air atmospheric pressure dew point [ C] P =.3 MPa P =.5 MPa P =.7 MPa IDG6 3 IDG6H Outlet air flow rate [l/min [ANR]]

52 76 Series IDG Membrane Dryer Performance Charts IDG75, 75H IDG, H Outlet air atmospheric pressure dew point [ C] P =.3 MPa P =.5 MPa P =.7 MPa 3 IDG75 4 IDG75H Outlet air flow rate [L/min [ANR]] Outlet air atmospheric pressure dew point [ C] P =.3 MPa P =.5 MPa P =.7 MPa 3 IDG 4 IDGH Outlet air flow rate [l/min [ANR]] Standard dew point 4 C [: L], 6 C [: S] IDG3LA, 5LA IDG6LA, 6SA Outlet air atmospheric pressure dew point [ C] P =.3 MPa P =.5 MPa 3 P =.7 MPa 4 5 IDG5LA 6 IDG3LA Outlet air flow rate [l/min [ANR]] Outlet air atmospheric pressure dew point [ C] P =.3 MPa P =.5 MPa 3 P =.7 MPa IDG6SA 4 5 IDG6LA Outlet air flow rate [l/min [ANR]] IDG75LA, 75SA IDGLA, SA Outlet air atmospheric pressure dew point [ C] P =.3 MPa P =.3 MPa P =.5 MPa P =.7 MPa 3 IDG75SA 4 5 IDG75LA Outlet air flow rate [l/min [ANR]] Outlet air atmospheric pressure dew point [ C] P =.5 MPa 3 IDGS P =.7 MPa IDGL Outlet air flow rate [l/min [ANR]] How to read the Performance Chart and to select the model Solid lines and dashed lines beginning at the top indicate the performance at 5 C of inlet air temperature and P =.3 MPa,.5 MPa, and.7 MPa of inlet air pressure, respectively. In the case of 5 C of inlet air temperature and 45 [L/min] of outlet air flow rate Model : The atmosphere pressure dew point at P =.7 MPa: 5 C. In the case of 4 C of inlet air temperature and 45 [L/min] of outlet air flow rate Example) Outlet air flow rate correction factor:.6 (The correction factor differs depending on the model. Corrected outlet air flow rate: 45.6 = 75 [L/min] Model : Performing corresponding to 5 C of outlet atmosphere pressure dew point at P =.7 MPa. Outlet air atmospheric pressure dew point [ C] Model : P =.3 MPa Model : P =.3 MPa Outlet air flow rate [L/min] P =.3 MPa P =.5 MPa P =.7 MPa Model : P =.7 MPa Model : P =.7 MPa

53 Membrane Dryer Series IDG 77 Replacement Parts Description Membrane module kit Dew point indicator kit IDG IDG3 IDG3H IDG5 IDG5H IDG IDGH IDG IDGH IDG3A IDG5A IDG-EL3 IDG-EL3H IDG-EL5 IDG-EL5H IDG-EL IDG-ELH IDG-EL IDG-ELH IDG-EL3A IDG-EL5A With Orifice ( pc.), O-ring (3 pcs.), Gasket ( pc.) IDG-DP (Option: S) IDG-DP-X (Option: PS) With O-ring ( pc.) With O-ring ( pc.) With Orifice ( pc.), Silencer ( pc.), O-ring (4 pcs.) IDG-DP IDG-DP-X (Option: P) Part no. With Nozzle ( pc.), Adapter ( pc.), O-ring ( pc.) IDG6 IDG6H IDG6LA IDG6SA IDG75 IDG75H With O-ring ( pc.) IDG-DP IDG75LA IDG75SA IDG-DP-X (Option: P) IDG IDGLA IDGH IDGSA IDG-EL6 IDG-EL6LA IDG-EL75 IDG-EL75LA IDG-EL IDG-ELLA Dimensions IDG (93) (67) Purge air for dehumidification (46) (6) Purge air discharge tubing port for dehumidification Applicable tubing O.D.: ø6 IN Port size: /4 Hexagon width across flats 9 Hexagon width across flats 4 ø8 Hexagon width across flats 4 Hexagon width across flats 7 With fitting for purge air discharge (Option: P) (34) (5) (86) (67) Purge air for dehumidification Port size: /4 IDG3, 5 IDG3H, 5H Purge air Dew point indicator (Option: S).3 Hexagon width across flats With fitting for purge air discharge (Option: P) (98) (Maintenance space mm or more) Bracket (Accessory: B) IDG, IDGH, H 6 A E Purge air IN D B 7 6 Hexagon width across flats 4 Purge air for dehumidification IN 8 4 Port size: /8, /4 Purge air discharge tubing port for dehumidification Applicable tubing O.D.: ø8 or ø5/6 inch (64) Port size L C With fitting for purge air discharge (Option: P) (H) Purge air discharge tubing port for dew point indicator Applicable tubing O.D.: ø8 or ø5/6 inch 4 Bracket (Accessory: B) (G) Purge air for dehumidification Purge air for dehumidification Purge air discharge tubing port for dehumidification Applicable tubing O.D.: øj (F) (Maintenance space mm or more) Model IDG, H IDG, H Port size L /4, 3/8 A B C D E Option: P F G H J

54 78 Series IDG Membrane Dryer Dimensions IDG3A IDG5A With fitting for purge air discharge (Option: P) Port size L Purge air discharge tubing port for dew point indicator Applicable tubing O.D.: ø8 or ø5/6 inch IN 8 Port size L With fitting for purge air discharge (Option: P) 6 Purge air discharge tubing Purge air.3 4 port for dew point indicator 4 Applicable tubing O.D.: ø8 or ø5/6 inch 6 Bracket (Accessory: B) 7 IN IN 97 7 (H) (D) (B) (G) Purge air for dew 4 point indicator 7 IN Bracket (Accessory: B) (G) 8 (D) (B) (H) Purge air for dehumidification (Maintenance space mm or more) Purge air discharge tubing port for dehumidification Applicable tubing O.D.: ø IDG6, 75, IDG6A, 75A, A 8 Purge air for dehumidification (Maintenance space mm or more) Model Port size Option: P B D L G H IDG3A /4, 3/8 IDG5A IDG6 3/8, / IDG75, / IDG6A IDG75A 3/8, / IDGA Purge air discharge tubing port for dehumidification Applicable tubing I.D.: ø9

55 Moisture Control Tube Series IDK 79 Moisture Control Tube Series IDK Features Advanced fluoropolymer that eliminates water condensation. Vapour diffusing process ejects water to the outside. How to Order IDK 4 6 Moisture control tube O.D. O.D. mm 4 mm 6 mm Moisture control tube effective length Effective length mm mm Product Recommendation Stocked items for fast delivery IDK- IDK4- IDK6- IDK- IDK4- IDK6- Specifications Model Fluid Max. operating pressure Operating temperature [ºC] Operating environment Min. bending radius [mm] O.D. [mm] I.D. [mm] Quantity of moisture control tubes Accessories Colour Applicable fittings Material IDK IDK4 IDK6 Compressed air.7 MPa to 4 (No freezing) Indoors, where product is not exposed to water ( to 4ºC, Relative humidity to 75%RH). 4.5 pcs. Inner sleeve 4 pcs. (already mounted into tube) Colour will change to brown over time, Transparent but the functions are not affected. KQ Fluoropolymer Note ) Use the moisture control tube in a line with a refrigerated air dryer and a mist separator installed in the upstream compressed air line. The condensation prevention performance may be lowered depending on the quality of the supply compressed air (oil, dew point). Note ) The inner sleeve is already mounted and cannot be removed. If the inner sleeve comes off, re-insert the sleeve before mounting the fitting. Note 3) Do not cut the tube. Inner sleeve Use the product in an operating environment where humidity is as low as possible. The value at which the moisture control tube is bent or flattened at ºC. Be careful not to bend or flatten the tube and the inner sleeve even if the value is more than the minimum bending radius. R Related Products Series MXQ - Slide Table - page 73 Series CXS/J - Dual Rod Cylinder - page 784 Series MH - Grippers - page 954 Series CRB - Rotary Actuators - page 98 Series MSQ - Rotary Actuators - page 93 Series CQ - Compact Cylinder - page 653 Series CY - Rodless Cylinder - page 756 Series CU - Free Mount Cylinder - page 68 Series RSQ - Stopper Cylinder - page 795 Series C85 - ISO Cylinder - page 64 D Dimensions L X Inner sleeve Model IDK- IDK- IDK4- IDK4- IDK6- IDK6- O.D. x I.D. D x. 4 x.5 6 x 4 Nominal effective length X Note) Dimensions at 4% relative humidity. Dimensions may change if the relative humidity changes. Unit: [mm] Full length L

56 8 Series IDK Moisture Control Tube Selection Procedure Check the presence of condensation. () The presence of condensation can be verified by the dew point and the Kv value (the volume ratio of tube and actuator) of the supply air. Select the length of moisture control tube for the condensation area. Fig. Verification Chart of Condensation Supply air dew point (Atmospheric pressure dew point) [ºC] Noncondensation area Condensation area.4 MPa.5 MPa.6 MPa.7 MPa Volume ratio [Kv] () Find L, the necessary length corresponding to the Kv value, from the length selection chart at basic conditions. Fig. 3 Length Selection Chart at Basic Conditions Necessary length to prevent condensation L [mm] O.D. mm tube Basic conditions Supply dew point: ºC (Atmospheric pressure dew point) Supply pressure:.5 MPa Solenoid valve operating intervals: s (ON) s (OFF) Ambient temperature: 5ºC Ambient humidity: 4% Kv value O.D. 6 mm tube O.D. 4 mm tube Calculation method of volume ratio (Kv value) Calculate the piping volume Vt and the actuator volume Vc and substitute them into equation q below. Vt Kv : Volume ratio Kv = q Vt : Piping volume [mm 3 ] Vc Vc : Actuator volume [mm 3 ] Fig. Piping Volume Chart Tube volume [mm 3 ] Vt = πd l 4 Vc = πd s Vt : Piping volume (mm 3 ) [can be selected from piping volume chart in Fig..] d : Tube I.D. [mm] l : Tube piping length [mm] Tube length means the length from the switch valve (e.g. solenoid valve) to the actuator. Vc : Actuator volume [mm 3 ] D : Bore size [mm] s : Stroke [mm] ø6 tube ø4 tube () If your operating conditions are different from these basic conditions, apply a correction factor. Necessary effective length = Basic condition length L x Correction factor C x C x C3 Correction Factor C for Supply Dew Point Supply air dew point [ºC] 3 4 Correction factor C.5.5 Correction Factor C for Ambient Relative Humidity Temperature Correction factor C Relative humidity ºC 5ºC % 4% 6% 75% Correction Factor C3 for Supply Pressure Supply pressure Correction factor [MPa] C ºC ø tube Tube piping length from the switch valve to the actuator [mm]

57 Moisture Control Tube Series IDK 8 Circuit conditions Actuator : CUJB4-6D Bore size D : 4 mm Stroke s : 6 mm Tube size : O.D. 6 mm x I.D. (d) 4 mm Tube piping length l : 5 m Supply air pressure :.3 MPa Supply air dew point : ºC (Atmospheric pressure dew point) Ambient environment : Temperature 5ºC, Humidity 6% Check the presence of condensation. () Calculation method of volume ratio (Kv value) Vt = πd l π x 4 x 5 = 4 4 = 68 mm 3 Vc = πd s π x 4 x 6 = = 75 mm Kv = Vt = 837 Vc Verify the presence of condensation. () Refer to the verification chart of condensation. Check whether the volume ratio (Kv) and the supply air dew point intersect in the condensation area. With the conditions above, they intersect in the condensation area, meaning condensation will occur. Fig. Verification Chart of Condensation Supply air dew point (Atmospheric pressure dew point) [ºC] Check the presence of condensation. Note) For dual piston cylinder, the volume ratio will be / of the volume ratio calculated above Confirmed that the intersection is in the condensation area Noncondensation area.4 MPa Condensation area.5 MPa.6 MPa.7 MPa Volume ratio [Kv] () Find the necessary length L from the length selection chart at basic conditions and Kv value. Fig. Length Selection Chart at Basic Conditions Necessary length to prevent condensation L [mm] Select the length of moisture control tube O.D. 6 mm tube O.D. 4 mm tube O.D. mm tube Necessary length at basic conditions (lower right of the chart) is approx. 8 mm. Basic conditions Supply dew point: ºC (Atmospheric pressure dew point) Supply pressure:.5 MPa Solenoid valve operating intervals: s (ON) s (OFF) Ambient temperature: 5ºC Ambient humidity: 4% Kv value () If your operating conditions are different from these basic conditions, apply a correction factor. Necessary effective length = Basic condition length L x Correction factor C x C x C3 In the example circuit, the conditions which are different from the basic conditions are: Supply dew point: ºC (Atmospheric pressure dew point) Supply pressure:.3 MPa Ambient environment: 5ºC, 6% (a) Find the correction factors. Supply air dew point correction factor C = Ambient air dew point correction factor C =.7 Supply pressure correction factor C3 =.4 (b) Find the necessary effective length after correction. Necessary effective length = 8 x x.7 x.4 mm Therefore, the moisture control tube IDK6- with effective length cm should be used. Correction Factor C for Supply Dew Point Supply air dew point [ºC] 3 4 Correction factor C.5.5 Basic conditions Supply dew point: ºC (Atmospheric pressure dew point) Supply pressure:.5 MPa Ambient environment: 5ºC, 4% Correction Factor C for Ambient Relative Humidity Temperature Correction factor C Relative humidity ºC 5ºC 4ºC % 4% 6% 8% Correction Factor C3 for Supply Pressure Supply pressure [MPa] Correction factor C

58 8 Series HED Chemical Thermo - con Chemical Thermo-con Series HED Features Allows direct control of chemical temperature. PFA wetted material. Compact / Lightweight. Operating temperature range: ºC TO 6ºC Temperature stability: ±.ºC How to Order Temperature controller + Heat exchanger Chemical Thermo-con HED 7 W B Cooling capacity 3 3 W 5 5 W 7 75 W Radiating method W Water-cooled 3 Communication A RS-485 B RS-3C Tube size 3 9 /" x 3/8" 3/4" x 5/8" Power supply Single-phase: 8 to 4 VAC 5/6 Hz Heat exchanger HED 7 H W 3 Cooling capacity W 5 W 75 W Heat exchanger Temperature controller Tube size 3 9 Radiating method W Water-cooled /" x 3/8" 3/4" x 5/8" Note) The tube size should be specified when ordering. HED 7 C B Cooling capacity 3 3 W 5 5 W 7 75 W Temperature controller Communication A RS-485 B RS-3C Power supply Single-phase: 8 to 4 VAC 5/6 Hz Related Products Series PFD - Digital Flow Switch for Chemicals - Series PF3W - Digital Flow Switch for Water - page 37 Series VX - Direct Operated Port Solenoid Valve - page 457 Series LV - Port Operated PFA Valves - Series LQ - Fluoropolymer Fittings - Series TL - PFA Tubing -

59 Chemical Thermo - con Series HED 83 Main Specifications Heat Exchanger Specifications Heat exchanger model HED3-HW3 HED3-HW9 HED5-HW3 HED5-HW9 HED7-HW3 HED7-HW9 Cooling capacity (Water) Note ) Heating capacity (Water) Note ) Cooling/Heating method Radiating method Operating temperature range 3 W 6 W 5 W W Peltier element (Thermoelectric device, Thermo-module) Water-cooled. to 6.ºC (depending on the type of circulating fluid) 75 W 8 W Applicable fluid Note ) Pure water, Hydrofluoric acid, Ammonia hydrogen peroxide solution, etc. Circulating Wetted material PFA fluid Operating pressure Note 3) (atmospheric pressure) to.35 MPa ( to 5.75 PSI) Tube size (PFA tube) /" x 3/8" 3/4" x 5/8" /" x 3/8" 3/4" x 5/8" /" x 3/8" 3/4" x 5/8" Temperature to 35ºC (no condensation) Wetted material FEP, Stainless steel 34, Stainless steel 36 Facility water Max. operating pressure.5 MPa (7.5 PSI) Tube size IN/: FEP tube 3/8" x /4" Flow rate 5 to l/min (.3 to.6 g/m) Ambient Temperature: to 35ºC, Humidity: 35 to 8%RH (no condensation) Dimensions Note 4) Weight Applied temperature controller W3 mm x D63 mm x H7 mm (W5." x D.4" x H6.69") Approx. 8 kg (7.6 lb) HED3-CA HED3-CB W5 mm x D94 mm x H mm (W5.9" x D.6" x H8.74") Approx. 4 kg (3.8 lb) HED5-CA HED5-CB W5 mm x D94 mm x H mm (W5.9" x D.6" x H8.74") Approx. 5 kg (33 lb) HED7-CA HED7-CB Note ) The conditions are as follows. Circulating fluid: Water (Circulating flow rate 5 l/min, Set temperature 5ºC); Facility water temperature: 5ºC; Facility water flow rate: 5 l/min; Ambient temperature: 5ºC Note ) For the compatibility between the circulating fluid and materials, please contact SMC. Note that the Chemical Thermo-con is not designed explosion proof so it is not suitable for flammable fluids. Note 3) Install the heat exchanger in the discharge side of a circulating pump. Do not use at location where a negative pressure is applied. The circulating fluid pump should be prepared by the customer. Note 4) The outline dimensions do not included protruding parts such as foot flange and tube. Temperature Controller Specifications Temperature controller model Communication HED3-CA RS-485 HED3-CB RS-3C HED5-CA RS-485 HED5-CB RS-3C HED7-CA RS-485 HED7-CB RS-3C Control method Operating temp. range Temperature stability Note ) Temperature sensor Main functions Ambient Cooling/Heating automatic shift PID control. to 6.ºC (no condensation) Within.ºC (with stable load) Resistance thermometer Pt, 3-wires, class A, ma (for both internal control sensor and external sensor) Note 4) Auto-tuning, Sensor fine adjustment, Offset, Learning control, External sensor control, Set value memory, Upper/lower temperature limit alarm, Output shutdown alarm, Remote ON/OFF, Leakage detection Temperature: to 35ºC, Humidity: 35 to 8%RH (no condensation) Power Power supply supply spec. Rated current Dimensions Note ) Mass Applied heat exchanger Note 3) 3A W mm x D3 mm x H5 mm (W3.94" x D.6" x H8.46") Approx. 6 kg (3. lb) HED3-HW3 HED3-HW9 Single-phase: 8 to 4 VAC 5/6 Hz 5A W4 mm x D35 mm x H5 mm (W5.5" x D3.8" x H8.46") Approx. 8 kg (7.6 lb) HED5-HW3 HED5-HW9 4A W65 mm x D447 mm x H5 mm (W6.5" x D7.6" x H8.46") Approx. 3 kg (8.6 lb) HED7-HW3 HED7-HW9 Note ) This value is for a stable load with no disturbance and cannot be achieved in determined operating conditions. Note ) The outline dimensions do not included protruding parts such as the foot flange, screw and connector. Note 3) The temperature controller should be connected with a specific series of heat exchanger. If connected with a different series of heat exchanger, it may not operate normally. (The HED3 and HED5 series use the same connector, so be careful for incorrect wiring.) Note 4) The external sensor should be prepared by the customer.

60 84 Series HED Chemical Thermo - con Maintenance Please prepare back-up equipment as necessary to minimize the downtime. ) Heat exchanger The heat exchanger will not be repaired in principle. Only the return to SMC for an investigation within warranty will be accepted. The return unit has to be completely decontaminated with appropriate method such as use of neutralizing agent before return to SMC. ) Temperature controller The temperature controller maintenance is only performed at SMC's site. On the other hand, following parts have a limited life and need to be replaced before th life ends. Parts Life Expectation Description Expected life Fan 5 to years DC power supply 5 to years Display panel 5, hours (approx. 5 years) Possible failure Lack of fan cooling because of the bearing life time. It will activate the overheat protection of DC power supply and generate an alarm. End life of electrolytic condenser. It will generate DC power supply alarm. End life of LCD display backlight. Cooling Capacity <Conditions> Circulating fluid: Water; Circulating fluid flow rate: 5 l/min; Facility water flow rate: 5 l/min The values shown on the performance chart are representative and not guaranteed. Allow a safety margin when choosing the product. HED3 HED5 Cooling capacity [W] Facility water: ºC Facility water: 5ºC Circulating fluid temperature [ºC] Facility water: 35ºC Cooling capacity [W] 8 4 Facility water: ºC Facility water: 5ºC Facility water: 35ºC Circulating fluid temperature [ºC] HED7 6 Cooling capacity [W] 8 4 Facility water: ºC Facility water: 5ºC Facility water: 35ºC Circulating fluid temperature [ºC]

61 Chemical Thermo - con Series HED 85 Heating Capacity <Conditions> Circulating fluid: Water; Circulating fluid flow rate: 5 l/min; Facility water flow rate: 5 l/min HED3 8 HED5 6 Heating capacity [W] Facility water: 35ºC 6 Facility water: 5ºC 4 Facility water: ºC Circulating fluid temperature [ºC] HED7 8 Heating capacity [W] Circulating fluid temperature [ºC] Facility water: 35ºC Facility water: 5ºC Facility water: ºC Heating capacity [W] Facility water: ºC Facility water: 35ºC Facility water: 5ºC Circulating fluid temperature [ºC] Pressure Loss in Circulating Fluid Circuit <Condition> Water HED3 HED5, HED7 Pressure loss (PSI) [kpa] (PSI) [kpa] HED3-HW HED3-HW Pressure loss HED5-HW3 HED7-HW3 HED5-HW9 HED7-HW9 5 5 l/min 3 4 g/min Flow rate 5 5 l/min 3 4 g/min Flow rate Pressure Loss in Facility Water Circuit <Condition> Water HED3 (PSI) [kpa] 4.5 HED5, HED7 (PSI) [kpa] Pressure loss Pressure loss l/min 5 3 g/min 5 Flow rate 5 l/min 5 3 g/min Flow rate

62 REMOTE ON/OFF + - FG SIGNAL DC SIGNAL DC EXT.SENSOR A B B FG ALARM COMMUNICATION REMOTE ON/OFF + - FG AC EXT.SENSOR A B B FG ALARM COMMUNICATION AC 86 Series HED Chemical Thermo - con Dimensions HED3-W () Communication connector (The RS-3C uses only lower side connector) Alarm output connector Terminal block (3) Temperature controller Heat exchanger HED3-C HED3-HW Display panel DC cable 5 m 7 65 Signal cable 5 m Circulating fluid outlet 3 3 Signal connector 75 9 DC connector Power supply connector (4) Fluid leak sensor Model No. plate (Heat exchanger) 63 Model No. plate (Controller) () POWER O N OFF Power supply switch Purge outlet (M5) 5 PURGE WATER CHEMICAL IN SI AL PURGE IN WATER IN Facility water outlet 3/8" x /4" 7 43 Purge inlet (M5) 4 Facility water inet 3/8" x /4" Circulating fluid inlet Circulating Fluid Tube Size Heat exchanger model Circulating fluid tube size HED3-HW3 /" x 3/8" HED3-HW9 3/4" x 5/8" HED5-W () 7 () Power Supply Cable (Accessory) Connector: IEC63 C3 or equivalent Cable: 4AWG, O.D. ø8.4 Wire colour Content Black 8 to 4 VAC Black 8 to 4 VAC Green/Yellow PE Communication connector (The RS-3C uses only right side connector) Alarm output connector Terminal block Temperature controller HED5-C Heat exchanger HED5-HW Signal cable 5 m (3) Model No. plate DC cable 5 m (Controller) 4 Display panel SI AL Circulating fluid outlet Signal connector DC connector Power supply connector (4) 8 Fluid leak sensor Model No. plate (Heat exchanger) 94 (8) POWER O N OFF Power supply switch 5 PURGE Purge outlet (M5) WATER CHEMICAL Facility water outlet 3/8" x /4" IN WATER IN PURGE IN Circulating fluid inlet Purge inlet (M5) 4 44 Facility water inlet 3/8" x /4" Circulating Fluid Tube Size Heat exchanger model Circulating fluid tube size HED5-HW3 /" x 3/8" HED5-HW9 3/4" x 5/8" 4 38 () 6 6 Power Supply Cable (Accessory) Connector: IEC63 C3 or equivalent Cable: 4AWG, O.D. ø8.4 Wire colour Content Black 8 to 4 VAC Black 8 to 4 VAC Green/Yellow PE

63 REMOTE ON/OFF + - FG DC EXT.SENSOR A B B FG SIGNAL AC Chemical Thermo - con Series HED 87 Dimensions HED7-W 33 3 () Communication connector The RS-3C uses only upper side connector. Alarm output connector 45 COMMUNICATION ALARM Fan Fluid leak sensor (3) Temperature controller HED7-C DC cable 5 m 65 Display panel POWER O N OFF 5 Signal cable 5 m Heat exchanger HED7-HW 9 PURGE WATER 75 CHEMICAL IN 5 SI WATER IN AL PURGE IN Circulating fluid outlet Terminal block DC connector Signal connector Power supply connector 5 8 (4) Model No. plate (Heat exchanger) 94 (8) Model No. plate (Controller) Power supply switch Facility water outlet 3/8" x /4" Circulating fluid inlet Facility water inlet 3/8" x /4" Purge outlet (M5) Purge inlet (M5) () Circulating Fluid Tube Size Heat exchanger model Circulating fluid tube size HED7-HW3 /" x 3/8" HED7-HW9 3/4" x 5/8" Power Supply Cable (Accessory) Connector: DDK CE5-6A8-SD-D-BSS Cable: AWG, O.D. ø.8 Wire colour Content Black 8 to 4 VAC Black 8 to 4 VAC Green/Yellow PE

64 88 Series HRS Thermo - Chiller Thermo-Chiller Series HRS Features Space-saving product as it is compact and lightweight. Increase/decrease of the circulating fluid using two electronic expansion valves. Temperature range setting: 5 to 4ºC Temperature stability: ±.ºC How to order Single-phase to 3 VAC HRS 8 A Cooling capacity Cooling capacity /3 W (5/6 Hz) Cooling capacity 7/9 W (5/6 Hz) Cooling capacity /4 W (5/6 Hz) Cooling capacity 47/5 W (5/6 Hz) Note) UL standards: Applicable to 6 Hz only F A W Cooling method -cooled refrigeration Water-cooled refrigeration Thread type G (with PT-G conversion fitting set) Power supply Note) Power supply Single-phase to 3 VAC (5/6 Hz) Note) UL standards: Applicable to 6 Hz only Option B J M T G Option None With earth leakage breaker With automatic water supply function Applicable to DI water (deionized water) piping High-lift pump Note ) High-temperature environment specifications Note ) When multiple options are combined, indicate symbols in alphabetical order. Note ) The cooling capacity reduces about 3 W from the value in the catalog. For HRS5, high-lift pump is available as standard. Note ) -cooled V types, HRS/8/4 only. Product Recommendation Related Products Stocked items for fast delivery Series PF3W - Digital Flow Switch for Water - page 37 Series ZSE/ISE8 - Digital Pressure Switch for Fluids - page 9 HRS-AF- HRS-WF- HRS8-AF- HRS8-WF- HRS4-AF- HRS4-WF- Series VNB - Port Operated Valves - page 466 Series VXZ - Pilot Operated Port Solenoid Valves - page 45

65 Thermo - Chiller Series HRS 89 Specifications There are different values from standard specifications. [kg] Model HRS-A- HRS-W- HRS8-A- HRS8-W- HRS4-A- HRS4-W- HRS5-A- HRS5-W- Cooling method -cooled refrigeration Water-cooled refrigeration -cooled refrigeration Water-cooled refrigeration -cooled refrigeration Water-cooled refrigeration -cooled refrigeration Water-cooled refrigeration Refrigerant R47C (HFC) R4A (HFC) Control method Ambient temperature/humidity Note ) Circulating fluid Note 3) Temperature range setting Note ) [ C] PID control Temperature: 5 to 4 C, High-temperature environment specifications (option): 5 to 45 C, Humidity: 3 to 7% Clear water, 5% ethylene glycol aqueous solution Note 5) 5 to 4 Cooling capacity Note 4) (5/6 Hz) [W] /3 7/9 /4 47/5 Heating capacity Note 4) (5/6 Hz) [W] 53/65 /4 /3 Temperature stability Note 6) [ C] ±. Rated flow Note 7) Note 8) (5/6 Hz) [L/min] 7 (.3 MPa)/7 (.8 MPa) 3 (.4 MPa)/8 (.3 MPa) Maximum flow rate (5/6 Hz) [L/min] 7/9 3/4 Maximum high-lift (5/6 Hz) [m] 4/9 5 Output [W] 55 Tank capacity [L] Approx. 5 Port size Wetted parts material Rc/ Stainless steel, Copper (Heat exchanger brazing), Bronze, Alumina ceramic, Carbon, PP, PE, POM, FKM, EPDM, PVC Temperature range [ C] 5 to 4 5 to 4 5 to 4 5 to 4 Pressure range [MPa].3 to.5.3 to.5.3 to.5.3 to.5 Required flow rate Note ) (5/6 Hz) [L/min] Inlet-outlet pressure differential of facility water [MPa].3 or more.3 or more.3 or more.3 or more Port size Rc3/8 Wetted parts material Power supply Circuit protector [A] Stainless steel, Copper (Heat exchanger brazing), Bronze, Synthetic rubber Single-phase to 3 VAC (5/6 Hz) Allowable voltage range ±% Applicable earth leakage breaker capacity Note 9) [A] Rated operating current [A] 4.6/5. 4.7/5. 5./5.9 8/ 7.6/ Rated power consumption Note 4) (5/6 Hz) [kva].9/..9/../..7/..55/. Noise level Note ) (5/6 Hz) [db] 6/6 65/68 Fitting (for drain outlet) pc. Note 3), Input/output signal connector pc., Power supply connector pc. Note 3), Accessories Operation manual (for installation/operation), Quick manual (with a clear case) Note 3), Alarm code list sticker, Ferritic core (for communication) pc. Power supply cable should be ordered the option (sold separately) or prepared by the customer. Weight Note ) Circulating fluid system Facility water system Note ) Electrical system Pump Note ) For water-cooled refrigeration Note ) It should have no condensation. Note 3) If clear water is used, use water that conforms to Water Quality Standards of the Japan Refrigeration and Conditioning Industrial Association (JRA GL--994 cooling water system - circulating type - make-up water). Note 4) q Ambient temperature: 5 C, w Circulating fluid temperature: C, e Rated circulating fluid flow rate, r Circulating fluid: Clear water, t Facility water temperature: 5 C Refer to the cooling capacity graph on page 3 for details. Note 5) Use a 5% ethylene glycol aqueous solution if operating in a place where the circulating fluid temperature is C or less. Note 6) Outlet temperature when the circulating fluid flow is rated flow, and the circulating fluid outlet and return port are directly connected. Installation environment and the power supply are within specification range and stable. Note 7) The capacity at the Thermo-chiller outlet when the circulating fluid temperature is C. Note 8) Required min. flow rate for cooling capacity or maintaining the temperature stability. The specification of the cooling capacity and the temperature stability may not be satisfied if the flow rate is lower than the rated flow. (In such a case, use a by-pass piping set (sold separately).) Note 9) Purchase an earth leakage breaker with current sensitivity of 3 ma separately. (A product with an optional earth leakage breaker (option B) is also available.) Note ) Front: m, height: m, stable with no load, Other conditions Note 4) Note ) Weight in the dry state without circulating fluids Note ) Required flow rate when a load for the cooling capacity is applied at a circulating fluid temperature of C, and rated circulating fluid flow rate and facility water temperature of 5 C. Note 3) It is not provided for HRS5.

66 9 Series HRS Thermo - Chiller Accessories q Anti-quake Bracket Bracket for earthquakes Prepare the anchor bolts (M8) which are suited to the floor material by the customer. (Anti-quake bracket thickness:.6 mm) Part No. (for single unit) HRS-TK HRS-TK HRS-- HRS8-- HRS4-- HRS5-- HRS/8/4 HRS5 Anchor bolt (M8) (Prepared by the customer) 555 mm (59 mm) 664 mm (698 mm) Mounting view Anti-quake bracket Material: Zinc steel plate 4 mm 4 mm (335 mm) (335 mm) w Piping Conversion Fitting (For -Cooled Refrigeration) Conversion fitting for circulating fluid + Conversion fitting for drain outlet HRS-A-, HRS8-A-, HRS4-A- This fitting changes the port size for circulating fluid from Rc/ to G/ or NPT/, and for drain from Rc 3/8 to G3/8 or NPT3/8. It is not necessary to purchase this when pipe thread type F or N is selected in How to Order since it is included in the product. Part No. Applicable model HRS-EP G thread conversion fitting set HRS-A- HRS8-A- HRS-EP NPT thread conversion fitting set HRS4-A- When the options, with automatic water supply function -J, or high-lift pump -T are selected, purchase r piping conversion fitting (for option), too. HRS5-A- This fitting changes the port size for circulating fluid from Rc/ to G/ or NPT/, and for drain from Rc /4 to G/4 or NPT/4. It is not necessary to purchase this when pipe thread type F or N is selected in How to Order since it is included in the product. Part No. Applicable model HRS-EP9 G thread conversion fitting set HRS5-A- HRS-EP NPT thread conversion fitting set When the option, with automatic water supply function -J, is selected, purchase r piping conversion fitting (for option), too. Protrusion when the conversion fitting for circulating fluid is mounted Approx. 43 mm Protrusion when the conversion fitting for circulating fluid is mounted Approx. 43 mm Conversion fitting for circulating fluid Material: Stainless steel pcs./set Conversion fitting for drain outlet Material: POM pc. Conversion fitting for circulating fluid Material: Stainless steel pcs./set Conversion fitting for drain outlet Material: Stainless steel pc.

67 Thermo - Chiller Series HRS 9 Accessories e Piping Conversion Fitting (For Water-Cooled Refrigeration) Conversion fitting for circulating fluid + Conversion fitting for facility water + Conversion fitting for drain outlet HRS-W-, HRS8-W-, HRS4-W- This fitting changes the port size for circulating fluid from Rc/ to G/ or NPT/, for facility water from Rc3/8 to G3/8 or NPT3/8, and for drain from Rc3/8 to G3/8 or NPT3/8. It is not necessary to purchase this when pipe thread type F or N is selected in How to Order since it is included in the product. Part No. Applicable model HRS-EP3 G thread conversion fitting set HRS-W- HRS8-W- HRS-EP4 NPT thread conversion fitting set HRS4-W- When the options, with automatic water supply function -J, or high-lift pump -T are selected, purchase r piping conversion fitting (for option), too. Protrusion when the conversion fitting for facility water is mounted Approx. 37 mm Conversion fitting for circulating fluid Material: Stainless steel pcs./set Conversion fitting for facility water Material: Stainless steel pcs./set Conversion fitting for drain outlet Material: POM pc. HRS5-W- This fitting changes the port size for circulating fluid from Rc/ to G/ or NPT/, for facility water from Rc3/8 to G3/8 or NPT3/8, and for drain from Rc /4 to G/4 or NPT/4. It is not necessary to purchase this when pipe thread type F or N is selected in How to Order since it is included in the product. Part No. Applicable model HRS-EP G thread conversion fitting set HRS5-W- HRS-EP NPT thread conversion fitting set When the option, with automatic water supply function -J, is selected, purchase r piping conversion fitting (for option), too. Protrusion when the conversion fitting for facility water is mounted Approx. 37 mm Conversion fitting for circulating fluid Material: Stainless steel pcs./set Conversion fitting for facility water Material: Stainless steel pcs./set Conversion fitting for drain outlet Material: Stainless steel pc. r Piping Conversion Fitting (For Option) Conversion fitting for automatic water supply inlet This fitting changes the port size for option-j With Automatic Water Supply Function from Rc3/8, Rc3/4 to G3/8, G3/4 or NPT3/8, NPT3/4. It is not necessary to purchase this when pipe thread type F or N is selected in How to Order since it is included in the product. Part No. Applicable model HRS---J HRS-EP5 G thread conversion fitting set HRS8---J HRS4---J HRS-EP6 NPT thread conversion fitting set HRS5---J Conversion fitting for automatic water supply inlet Material: Stainless steel pc. of each/set Conversion fitting for drain outlet This fitting changes the port size for drain outlet for option-t High-lift Pump from Rc/4 to G/4 or NPT/4. It is not necessary to purchase this when pipe thread type F or N is selected in How to Order since it is included in the product. Part No. Applicable model HRS---T HRS-EP7 G thread conversion fitting HRS8---T HRS4---T HRS-EP8 NPT thread conversion fitting HRS5-- Note ) Note ) It is not necessary to purchase this when you purchase HRS-EP9 to since it is included in the product. Conversion fitting for high-lift pump drain outlet Material: Stainless steel pc.

68 9 Series HRS Thermo - Chiller Cooling Capacity HRS-A-, HRS-W- (Single-phase to 3 VAC) Cooling capacity [W] 5 5 [5 Hz] Ambient temperature or facility water temperature 5 C 3 C 5 4 C Circulating fluid temperature [ C] Cooling capacity [W] C [6 Hz] Ambient temperature or facility water temperature 3 C 5 4 C Circulating fluid temperature [ C] HRS8-A-, HRS8-W- (Single-phase to 3 VAC) Cooling capacity [W] Cooling capacity [W] [5 Hz] 5 5 C C 4 C 5 Ambient temperature or facility water temperature Circulating fluid temperature [ C] HRS4-A-, HRS4-W- (Single-phase to 3 VAC) C [5 Hz] 5 3 C 4 C 5 Ambient temperature or facility water temperature Circulating fluid temperature [ C] Cooling capacity [W] Cooling capacity [W] [6 Hz] 5 Ambient temperature or facility water temperature Circulating fluid temperature [ C] 35 5 C 4 C 3 C [6 Hz] 3 5 C 4 3 C 5 4 C 5 Ambient temperature or facility water temperature Circulating fluid temperature [ C] HRS5-A-, HRS5-W- (Single-phase to 3 VAC) Cooling capacity [W] C 3 C 4 C Ambient temperature [5 Hz] Cooling capacity [W] C 3 C 4 C Ambient temperature [6 Hz] Circulating fluid temperature [ C] Circulating fluid temperature [ C]

69 Thermo - Chiller Series HRS 93 Dimensions HRS/8/4 Power switch Power entry Circulating fluid return port Rc/ Handle 5 () (35) Circulating fluid fill port lid Operation display panel 377 Water-cooled refrigeration Facility water outlet Rc3/8 65 Water level indicator Facility water inlet Rc3/8 Drain port with O-ring sealing plug Circulating fluid outlet Rc/ The power supply cable is not provided. (The power supply connector is provided.) The conversion fitting (R3/8 male thread) is provided. Caster (unfixed) with locking lever Caster (unfixed) Dustproof filter Ventilation air inlet (-cooled only) Ventilation air outlet (-cooled only) HRS5-A Serial communication (RS-485/RS-3C) connector D-sub female receptacle Power cable entry (Grommet with membrane) Maintenance connector Contact input/output communication connector Optional connector Optional connector Circulating fluid return port Rc/ 59 Ventilation hole (Same for the opposite side) Circulating fluid fill port lid Operation display panel 377 Water level indicator Breaker Product label Circulating fluid outlet Rc/ Handle (Same for the opposite side) Drain port Rc/4 (Valve stopper) Caster (unfixed) with locking lever Ventilation air outlet Caster (unfixed) Dustproof filter Ventilation air inlet Ventilation air outlet HRS5-W Ventilation air outlet Serial communication (RS-485/RS-3C) connector D-sub female receptacle Maintenance connector Contact input/output communication connector Optional connector Circulating fluid fill port lid Operation display panel Power cable entry (Grommet with membrane) Optional connector Circulating fluid return port Rc/ Water level indicator Breaker Product label Circulating fluid outlet Rc/ Facility water outlet Rc/ Drain port Rc/4 (Valve stopper) Handle (Same for the opposite side) Facility water inlet Rc/ Caster (unfixed) Caster (unfixed) with locking lever Dustproof filter

70 94 Series IDH Thermo - dryer Thermo - dryer Series IDH Features Dehumidification function (dryer). Pressure regulation funtion (regulator). Cleaning function (filter). Temperature control function (heater). How to Order Size 4 6 IDHA 6 Size Rated air flow capacity 4 l/min [ANR] 6 l/min [ANR] Standard Specifications 3 Combination of built-in products Regulator Filter (AMH) Filter (AME) A B Note) Filter AMH: Micro mist separator with pre-filter. Filter AME: Super mist separator Voltage Voltage 3 Single-phase 3 VAC (5/6 Hz) Note) Other voltages available: VAC, VAC Related Products Series AMH - Micro Mist Separator with Pre-filter - Series AME - Super Mist Separator - Series AC - - page 76 Series TU - Tubing - page 3 Series KQ - Fittings - page 84 Series PFA - Digital Flow Swith for - page 39 Series ZSE/ISEA - Digital Pressure Switch for - page 73 Series VNB - Port Operated Valves - page 466 Series VXZ - Pilot Operated Port Solenoid Valves - page 45 Specifications Note) ) Operating range Rated conditions Note 3) Rated performance Electric specifications Built-in filter specifications Note 5) Model Fluid flow capacity Inlet air temperature Inlet air pressure Ambient temperature Outlet air temperature adjustment range Outlet air set pressure range flow capacity Inlet air pressure Inlet air temperature Ambient temperature Outlet air set temperature Outlet air pressure dew point Outlet air temperature stability Outlet air temperature display accuracy Power supply Note 4) Operating current Earth leakage breaker capacity Compressor input Heater input Nominal filtration rating Cleanliness of the filter outlet side Temperature control method Refrigerant type/refrigerant charge Noise level (reference value) Note 6) Weight Applicable drain tube O.D. Coating colour Applicable directive IDHA4-3 Note ) ANR is the value at ºC, atmospheric pressure, and relative humidity of 65%. Note ) The upper limit of the settable outlet air temperature varies depending on the conditions even within the operating range. Be sure to read the selection document before selecting the models. Note 3) Performance when the operation of each part is stable without fluctuations in operating conditions and power supply Compressed air to 5 l/min [ANR] to 8 l/min [ANR] 5 to 4 C.3 to. MPa 5 to 35 C (Relative humidity 85% or less) 5 to 3 C.5 to.85 MPa (The inlet air pressure should be at least.5 MPa higher than the outlet air pressure.) 4 l/min [ANR] 6 l/min [ANR].7 MPa 35 C 3 C 3 C C ±. C ±.5 C (including accuracy of the sensor) Single phase 3 VAC Single phase 3 VAC (5/6 Hz) (5/6 Hz). A 4.8 A 5 A A 8/ W 5/6 Hz 385/44 W 5/6 Hz W 4 W. μm (99.9% filtration efficiency) Particles of.3 μm or more: 3.5 particles/l [ANR] or less Heater operation, PID control R34a/.4 kg 5 db(a) 6 kg IDHA6-3 R34a/.6 kg 55 db(a) 37 kg mm Body panel: White Base: Grey Low Voltage Directive: 6/95/EC EMC Directive: 4/8/EC Note 4) Keep the voltage within -5 to +% of the rated voltage. If there is voltage fluctuation, the outlet air temperature stability may decrease. So if highly accurate temperature adjustment is required, please use a stable power supply to make the voltage fluctuation smaller. Note 5) The specification changes depending on the cleanliness of the inlet side air. It may take time until the cleanliness of the filter outlet side air stabilises immediately after start of operation. The filter performance only applies to the built-in type filter. Note 6) m in front of the product, m in height, without load, stable conditions

71 Thermo - dryer Series IDH 95 Specifications Output Signal Description Operating signal N.O. (a contact) Error signal N.C. (b contact) Error signal N.O. (a contact) Operating signal Error signal N.O. (a contact) Error signal N.C. (b contact) Closed Open Closed Open Closed Open min Start of operation (manually) Terminal no st nd emergency stop emergency stop Note ) Description of operation Close after minutes of operation Open at an emergency stop or set temperature error Close at an emergency stop or set temperature error Within 6 min Output signal timing chart Contact capacity Resistance load A, Induction load 8 VA, Lamp load W 6 min Temperature Normalisation of error signal temperature error Note ) The operation does not stop 3rd 4th 5th st nd 3rd 4th during temperature error. emergency stop emergency stop emergency stop emergency stop emergency stop emergency stop emergency stop Automatic reset Note ) Automatic reset Restart (manually) Minimum load 5 VDC ma min Note ) The operation can be started or restarted (manually) by the operation stop switch mounted on the thermo-dryer or a remote switch prepared by the user. Note ) When emergency stop is generated 5 times in an hour or the heater protection equipment (thermo-stat) is operated, the emergency stop status will be held. At this time, the dryer can be restarted by reset operation using the switch stated in Note. Flow Characteristics Condensed Water Calculation 45 How to calculate the amount of condensed water A F E Ambient temperature ( compressor intake air temperature) [ C] Pressure dew point [ C] Dew Point Conversion Chart Pressure dew point [ C] A Relative humidity % B 8% B C 6% 4% % Amount of moisture in air (g/m 3 ) MPa.3 MPa. MPa.9 MPa.7 MPa.5 MPa.3 MPa. MPa Atmospheric pressure 3 5 Amount of condensed water C H 8. 3.=5. g/m 3 C 5 5 H G Atmospheric pressure. MPa..3.4 D Example) To obtain the amount of condensed water when the pressure is applied to air up to.7 MPa with an air compressor, then cooled down to 5 C. Given an ambient temperature at 3 C and a relative humidity 6%.. Trace the arrow mark from the point A at an ambient temperature 3 C to obtain the intersection B on the curved line for the relative humidity 6%.. Trace the arrow mark from the intersection B to obtain the intersection D on the pressure characteristic line for.7 MPa. 3. Trace the arrow mark from the intersection D to obtain the intersection E. 4. The intersection E is the dew point under pressure.7 MPa with an ambient temperature 3 C and a relative humidity 6%. The value for E is 6 C. 5. Trace the intersection E upward, and trace from the intersection D leftward to obtain the intersection C. 6. The intersection C is the amount of moisture included in the compressed air m 3 at.7 MPa and a pressure dew point 6 C. The amount of moisture is 8. g/m Trace the arrow mark, starting from F for cooling temperature 5 C (pressure dew point 5 C) to obtain the intersection G on the pressure characteristic line for.7 MPa. 8. From the intersection G, trace the arrow mark to obtain the intersection H on the vertical axis. 9. The intersection H is the amount of moisture included in the compressed air m 3 at.7 MPa, and a pressure dew point 5 C. The amount of moisture is 3. g/m 3.. Therefore, the amount of condensed water is as follows (per m 3 ): The amount of moisture at the intersection C the amount of moisture at the intersection H = the amount of condensed water = 5. g/m 3 Atmospheric pressure dew point [ C] How to read the dew point conversion chart Example) To obtain the atmospheric pressure dew point at a pressure dew point C and a pressure.7 MPa.. Trace the arrow mark starting from the point A at a pressure dew point C to obtain the intersection B on the pressure characteristic line for.7 MPa.. Trace the arrow mark starting from the point B to obtain the intersection C at the dew point under atmospheric pressure. 3. The intersection C is the conversion value 7 C under atmospheric pressure dew point.

72 96 Series IDH Thermo - dryer Specifications IDHA4 56± 8± 4± inlet Rc3/8 Pressure adjustment handle 455 Ventilation direction 5 Temperature controller 97 7 Illuminated switch Evaporation thermometer 3± 9 35 outlet Rc3/ Ventilation direction Filter maintenance port Terminal block pressure gauge 44 Signal cable outlet (ø7) Grommet with membrane Signal cable outlet (ø7) Grommet with membrane Drain pipe fitting (Applicable tube O.D. ø) 4± 5 7 Ventilation air inlet (With dustproof filter) 7± 39± 9 35 inlet Rc/ outlet Rc/ Pressure adjustment handle Ventilation direction 485 Ventilation direction 5 Filter maintenance port Terminal block Temperature controller 36 7 Illuminated switch Evaporation thermometer pressure gauge ø ± 8 7 Ventilation air outlet IDHA6 4± 3± 44 Signal cable outlet (ø7) Grommet with membrane Signal cable outlet (ø7) Grommet with membrane 4 ø3 Drain pipe fitting (Applicable tube O.D. ø) 3 3± 8 3 4± 7 Ventilation air inlet (With dustproof filter) 5 Ventilation air outlet

73 Main Line Filter Series AFF 97 Main Line Filter Series AFF Features Main Line Filter. Nominal filtration rating: 3μm Filtration efficiency: 99% Can remove impurities such as oil, water and foreign matter in compressed air and cam improve the function of a dryer in the downstream, extend the life of precision filter, and prevent trouble with the equipment. AFF (For drain cock) AFF (For auto drain) How to Order AFFC to C AFF C F C 4C 8C C C Body size Applicable compressor output (guide). kw 3.7 kw 7.5 kw kw kw Size /8 /4 3/8 / 3/4 Port size Applicable body size C 4C 8C C C Thread type F G Conforms to ISO79-. Accessory Description B Bracket Bracket is included, (but not assembled). Auto Drain Specifications/Option Combinations : All draining specifications are available (including drain guide, J type). : N.C. auto drain (C type) is not available. : N.C. auto drain (C type) and N.O. auto drain (D type) are not available. F H R U T V Note F H R Note U T V Note Note Note) one of them selectable : Not available Option 3 Description F Rubber material: Fluororubber H For medium air pressure (.6 MPa) J Drain guide /4 female threaded 4 R IN- reversal direction U With differential pressure switch (3 V) 5 T With element service indicator V Degreasing wash, 6 white vaseline 4 Drain piping and piping for a stop valve such as ball valve are required. 5 Differential pressure gauge is included, (but not assembled). 6 Only body/housing is degreasing washed. Auto drain 3 Description Drain cock (Without auto-drain) C N.C. auto drain D N.O. auto drain 3 Refer to the table in left for the combination between the auto drain specification and option. (Only one draining specification is selectable). Product Recommendation Stocked items for fast delivery AFFC-F AFFC-FD AFFC-F AFFC-FD-H AFFC-FD-T AFF4C-FD AFF4C-FD-H AFF4C-FD-T AFF4C-F3D AFF4C-F3D-H AFF8C-F3D AFF8C-F3D-H AFF8C-F3D-T AFF8C-F4D AFF8C-F4D-H AFF8C-F4D-T AFFC-F4D AFFC-F4D-T AFFC-F6D AFFC-F6D-H AFFC-F6D-T AFFC-F6D AFFC-FD AFFC-FD-H AFFC-FD-T Related Products Series AM - Mist Separator - page 7 Series AD4/6 - Auto Drain Valve - Series ADH4 - Heavy Duty Auto Drain Valve - Series GD4-- - Differential Pressure Gauge - Series AC - Modular Units - page 76

74 98 Series AFF Main Line Filter How to Order AFF37B/75B AFF 37B 37B 75B Body size Applicable compressor output (guide) 37 kw 75 kw Thread type Type F G Option Description J Drain guide 4 female threaded 4 R IN- reversal direction T With element service indicator 4 Drain piping and piping for a stop valve such as ball valve are required. 4 Size Port size Applicable body size 37B 75B Auto drain Description Drain cock (Without auto drain) 3 D N.O. auto drain Refer to Auto Drain Specifications/Option Combinations. 3 Body size 75B is equipped with a ball valve (Rc3/8 female threaded). Accessory Description B Bracket Bracket is included, (but not assembled). Product Recommendation Related Products AFF37B-FD AFF37B-FD-T Stocked items for fast delivery Auto Drain Specifications/Option Combinations Auto drain specifications Option AFF37B-F4D AFF37B-F4D-T AFF75B-F4D AFF75B-F4D-T Auto drain specifications/option N.O. auto drain Drain guide 4 IN- reversal direction With element service indicator AFF75B-FD AFF75B-FD-T D J R T Series AM - Cleaning Filters - page 7 Series AD4/6 - Auto Drain Valve - page xxx Series ADH4 - Heavy Duty Auto Drain Valve - page xxx Series GD4-- - Differential Pressure Gauge - page xxx Series AC - Modular Units - page 76 : Available : Not available Auto drain specifications Option Applicable model D J R T AFF37B AFF75B Specifications Fluid Max. operating pressure Min. operating pressure Proof pressure Ambient and fluid temperature Nominal filtration rating Element life Compressed air. MPa.5 MPa.5 MPa 5 to 6ºC 3 μm (Filtration efficiency: 99%) years or when pressure drop reached. MPa With auto drain:. MPa (N.O. type) or.5 MPa (N.C. type) Model AFFC AFF4C AFF8C AFFC AFFC AFF37B AFF75B Rated flow Note) [l/min (ANR)] Port size 8, 4 4, ,, ,,, Mass [kg] Note) Max. flow at.7 MPa. Max. flow varies depending on the operating pressure Accessory Applicable model AFFC AFF4C AFF8C AFFC Bracket assembly AM-BM AM-BM AM-BM3 AM-BM4 (with mounting screws) AFFC AFF37B AFF75B AM-BM5 BM56 BM57

75 Main Line Filter Series AFF 99 Dimensions AFFC to C Auto drain C: With auto drain (N.C.) D: With auto drain (N.O.) N K U T D I L M Bracket (Accessory) øv Drain cock Gray: N.C. Black: N.O. ø one-touch fitting 34 A E B H C IN J Combination of D: With auto drain (N.O.) and H: For medium air pressure /4 female threaded Option J: Drain guide /4 female threaded M5 G Maintenance space Drain port Width across flats 4 /4 female threaded R P U: With differential pressure switch (with indicator) Y Z IN T: With element service indicator W X Q F S O IN Model AFFC AFF4C AFF8C AFFC AFFC Port size /8, /4 /4, 3/8 3/8, / /, 3/4 3/4, A B C D E F G 5 H I J K T Bracket related dimensions U L M V N O P Q R S [mm] Element Differential service pressure indicator related switch related dimensions dimensions W X Y Z

76 Series AFF Main Line Filter Dimensions Auto drain AFF37B Bracket (Accessory) D: With auto drain (N.O.) Drain cock: Black 34 ø one-touch fitting Option J: Drain guide /4 female threaded M5 Drain port 8 76 T: With element service indicator Dimensions AFF75B Bracket (Accessory) Auto drain D: With auto drain (N.O.) for AFF75B IN Option T: With element service indicator Maintenance space Drain Rc 3/8 female threaded Maintenance space 4 IN Width across flats 4 /4 female threaded 3/8 female threaded

77 Mist Separator Series AM Mist Separator Series AM Features Can remove oil mist in compressed air and remove particles such as rust or carbon of more than.3 μm. Modular connection is possible with AM5C to 55C. AM (For drain cock) AM (For auto drain) How to Order AM5C to 55C AM 55C F 5C 5C 35C 45C 55C Body size Applicable compressor output (guide). kw 3.7 kw 7.5 kw kw kw Port size Applicable body size Size 5C 5C 35C 45C 55C /8 /4 3 3/8 4 / 6 3/4 Thread type F G Conforms to ISO79-. B Accessory Description Bracket Bracket is included, (but not assembled). Auto Drain Specifications/Option Combinations : All draining specifications are available (including drain guide, J type). : N.C. auto drain (C type) is not available. : N.C. auto drain (C type) and N.O. auto drain (D type) are not available. F H R U T V Note F H R Note U T V Note Note Note) one of them selectable : Not available Option 3 Description F Rubber material: Fluororubber H For medium air pressure (.6 MPa) J Drain guide /4 female threaded 4 R IN- reversal direction U With differential pressure switch (3 VDC) 5 T Element service indicator V Degreasing wash, 6 white vaseline 4 Drain piping and piping for a stop valve such as ball valve are required. 5 Differential pressure gauge is included, (but not assembled). 6 Only body/housing is degreasing washed. Auto drain 3 Description Drain cock (Without auto drain) C N.C. auto drain D N.O. auto drain 3 Refer to the table in left for the combination between the draining specification and option. (Only one draining specification is selectable). Product Recommendation Stocked items for fast delivery AM5C-FD-H AM5C-F-T AM5C-F-D AM5C-F-D-H AM5C-F3 AM5C-F3C AM5C-F3D-H AM35C-F3D-H AM35C-F3-T AM35C-F4 AM35C-F4C AM35C-F4D AM35C-F4D-H AM35C-F4D-T AM35C-F4-J AM35C-F4-T AM45C-F4 AM45C-F4D AM45C-F6 AM45C-F6C AM45C-F6D AM45C-F6D-H AM45C-F6D-T AM55C-F6 AM55C-F6D AM55C-F AM55C-FD AM55C-FD-H AM55C-FD-T AM55C-F-T Related Products Series AFF - Main Line Filters - page 67 Series AD4/6 - Auto Drain Valve - Series ADH4 - Heavy Duty Auto Drain Valve - Series GD4-- - Differential Pressure Gauge - Series AC - Modular Units - page 76

78 Series AM Mist Separator How to order AM65/85 AM 65 F Body size Applicable compressor output (guide) kw kw Thread type F G Option Description J Drain guide 4 female threaded 4 R IN- reversal direction T With element service indicator 4 Drain piping and piping for a stop valve such as ball valve are required. Size 4 Port size Applicable body size Accessory Description B Bracket Bracket is included, (but not assembled). Auto drain Description Drain cock (Without auto drain) 3 D N.O. auto drain Refer to Auto Drain Specifications/Option Combinations. 3 Body size 85 is equipped with a ball valve (Rc3/8 female threaded). Product Recommendation Stocked items for fast delivery AM65-FD-T AM65-F4-T EAM65-FD EAM65-F4 EAM85-FD Related Products Series AFF - Main Line Filters - page 67 Series AD4/6 - Auto Drain Valve - Series ADH4 - Heavy Duty Auto Drain Valve - Series GD4-- - Differential Pressure Gauge - Series AC - Modular Units - page 76 Auto Drain Specifications/Option Combinations Auto drain specifications/option Auto drain specifications N.O. auto drain Drain guide 4 Option IN- reversal direction With element service indicator Specifications D J R T : Available : Not available Auto drain specifications Option Applicable model D J R T AM65 AM85 Fluid Max. operating pressure Min. operating pressure Proof pressure Ambient and fluid temperature Nominal filtration rating Oil mist density at outlet Element life Accessory Compressed air. MPa.5 MPa.5 MPa 5 to 6ºC.3 μm (Filtration efficiency: 99.9%) Max.. mg/m 3 (ANR) (.8 ppm) years or when pressure drop reached. MPa With auto drain:. MPa (N.O. type) or.5 MPa (N.C. type) Oil mist density at 3 mg/m 3 (ANR) blown out by compressor. Model AM5C AM5C AM35C AM45C AM55C AM65 AM85 Note) Rated flow [l/min (ANR)] Port size 8, 4 4, ,, ,,, Mass [kg] Note) Max. flow at.7 MPa. Max. flow varies depending on the operating pressure. Note) Refer to Made to Order for high flow type of AM85 or more. Applicable model Bracket assembly (with mounting screws) AM5C AM5C AM35C AM45C AM55C AM65 AM85 AM-BM AM-BM AM-BM3 AM-BM4 AM-BM5 BM56 BM57

79 Mist Separator Series AM 3 Dimensions AM5C to 55C D I Auto drain C: With auto drain (N.C.) D: With auto drain (N.O.) A E B M5 N H C IN K J U G Maintenance space T L M Drain port øv Bracket (Accessory) Drain cock Gray: N.C. Black: N.O. ø one-touch fitting 34 Combination of D: With auto drain (N.O.) and H: For medium air pressure /4 female threaded Option J: Drain guide /4 female threaded R P Q S Width across flats 4 U: With differential pressure switch (with indicator) Y /4 female threaded F Z IN T: With element service indicator W X O IN [mm] Model AM5C AM5C AM35C AM45C AM55C Port size /8, /4 /4, 3/8 3/8, / /, 3/4 3/4, A B C D E F G 5 H I 56 J K T Bracket related dimensions U L M V N O P 7 Q R S Element Differential service pressure indicator related switch related dimensions dimensions W X Y Z

80 4 Series AM Mist Separator Dimensions AM65 Auto drain D: With auto drain (N.O.) Bracket (Accessory) Drain cock: Black 3 IN 4 34 ø one-touch fitting Option J: Drain guide /4 female threaded M Drain port Width across flats 4 T: With element service indicator Dimensions AM Auto drain D: With auto drain (N.O.) for AM /8 female threaded Option T: With element service indicator Bracket (Accessory) 3 /4 female threaded Maintenance space 3 IN Drain Rc 3/8 female threaded Maintenance space IN

81 Micro Mist Separator Series AMD 5 Micro Mist Separator Series AMD Features Can separate and remove aerosol state oil mist in compressed air and remove particles such as carbon or dust of more than. μm. Use this product as a pre-filter for compressed air for precision instruments or clean room requiring higher clean air. Modular connection is possible with AMD5C to 55C. AMD (For drain cock) AMD (For auto drain) How to Order AMD5C to 55C AMD 55C F Body size 5C 5C 35C 45C 55C Thread type F G Conforms to ISO79-. Port size Applicable body size Size 5C 5C 35C 45C 55C /8 /4 3 3/8 4 / 6 3/4 Option 3 Description F Rubber material: Fluororubber H For medium air pressure (.6 MPa) J Drain guide /4 female thread 4 R IN- reversal direction U With differential pressure switch (3 VDC) 5 T With element service indicator V Degreasing wash, 6 white vaseline 4 Drain piping and piping for a stop valve such as ball valve are required. 5 Differential pressure gauge is included, (but not assembled). 6 Only body/housing is degreasing washed. Accessory Description B Bracket Bracket is included, (but not assembled). Auto drain 3 Description Drain cock (Without auto drain) C N.C. auto drain D N.O. auto drain 3 Refer to the table in left for the combination between the draining specification and option. (Only one draining specification is selectable). Auto Drain Specifications/Option Combinations : All draining specifications are available (including drain guide, J type). : N.C. auto drain (C type) is not available. : N.C. auto drain (C type) and N.O. auto drain (D type) are not available. F H R U T V Note F H R Note U T V Note Note Note) one of them selectable : Not available

82 6 Series AMD Micro Mist Separator How to Order AMD65/85 AMD 65 F Body size Auto drain specifications/option Auto drain specifications N.O. auto drain Drain guide 4 Option IN- reversal direction With element service indicator Thread type F G Port size Size Applicable body size Auto Drain Specifications/ Option Combinations : Available : Not available Product Recommendation D J R T Accessory Description B Bracket Bracket is included, (but not assembled). Auto drain specifications Option D J R T Auto drain Description Drain cock (Without auto drain) 3 D N.O. auto drain Refer to Auto Drain Specifications/Option Combinations. 3 Body size 85 is equipped with a ball valve (Rc3/8 female threaded). Applicable model AMD65 AMD85 Option Description J Drain guide 4 female threaded 4 R IN- reversal direction T With element service indicator 4 Drain piping and piping for a stop valve such as ball valve are required. Stocked items for fast delivery Related Products AMD5C-FD-H AMD5C-F AMD5C-FD AMD5C-F3 AMD5C-F3D AMD5C-F3D-H AMD5C-FD-T AMD35C-F3D-T AMD35C-F4 AMD35C-F4D AMD35C-F4D-H AMD35C-F4D-T AMD45C-F4D AMD45C-F6 AMD45C-F6D AMD45C-F6D-H AMD45C-F6D-T AMD55C-F6-T AMD55C-F AMD55C-FD-H AMD55C-FD-T AMD65C-F4D AMD65C-F4D-T EAMD85C-FD Series AFF - Main Line Filters - page 67 Series AD4/6 - Auto Drain Valve - Series ADH4 - Heavy Duty Auto Drain Valve - Series GD4-- - Differential Pressure Gauge - Series AC - Modular Units - page 76 Specifications Fluid Max. operating pressure Min. operating pressure Proof pressure Ambient and fluid temperature Nominal filtration rating Oil mist density at outlet Element life With auto drain:. MPa (N.O. type) or.5 MPa (N.C. type) Oil mist density at 3 mg/m 3 (ANR) blown out by compressor. Compressed air. MPa.5 MPa.5 MPa 5 to 6ºC. μm (Filtration efficiency: 99.9%) Max.. mg/m 3 (ANR) (Before saturated with oil, less than. mg/m 3 (ANR).8 ppm) years or when pressure drop reached. MPa Model Rated flow Note) [l/min (ANR)] AMD5C AMD5C 5 AMD35C AMD45C AMD55C 37 AMD65 6 AMD85 Port size 8, 4 4, ,, ,,, Mass (kg) Note) Max. flow at.7 MPa. Max. flow varies depending on the operating pressure. Accessory Applicable model Bracket assembly (with mounting screws) AMD5C AMD5C AMD35C AMD45C AM-BM AM-BM AM-BM3 AM-BM4 AMD55C AMD65 AMD85 AM-BM5 BM56 BM57

83 Micro Mist Separator Series AMD 7 Dimensions AMD5C to 55C Auto drain C: With auto drain (N.C.) D: With auto drain (N.O.) D I N K U T L M øv Bracket (Accessory) Drain cock Gray: N.C. Black: N.O. ø one-touch fitting 34 A E B H C IN Combination of D: With auto drain (N.O.) and H: For medium air pressure /4 female threaded Option J: Drain guide /4 female threaded R G U: With differential pressure switch (with indicator) Y Z IN W X J M5 Maintenance space P Q Drain port S Width across flats 4 /4 female threaded F O T: With element service indicator IN Model AMD5C AMD5C AMD35C AMD45C AMD55C Port size /8, /4 /4, 3/8 3/8, / /, 3/4 3/4, A B C D E F G 5 H I 56 J K T Bracket related dimensions U L M V N O P 7 Q R S [mm] Element Differential service pressure indicator related switch related dimensions dimensions W X Y Z

84 8 Series AMD Micro Mist Separator Dimensions AMD Bracket (Accessory) Auto drain D: With auto drain (N.O.) 3 4 Drain cock: Black IN ø one-touch fitting Option J: Drain guide /4 female threaded M5 Drain port T: With element service indicator Maintenance space Width across flats 4 /4 female threaded

85 Micro Mist Separator Series AMD 9 Dimensions AMD85 Auto drain x port size Bracket (Accessory) D: With auto drain (N.O.) for AMD85 IN IN 348 Option T: With element service indicator 6 Drain Rc 3/8 female threaded Maintenance space 3 3/8 female threaded

86 Series AMG Water Separator Water Separator Series AMG Features Can remove water droplets in compressed air. Use this product in cases where water must be avoided, but not so dry as when an air dryer is used. Through the adoption of an element that is exclusively used for removing water droplets and the ample housing interior space, a 99% water removal rate has been achieved. Modular connection is possible with AMG5C to 55C. AMG (For drain cock) AMG (For auto drain) How to Order AMG5C to 55C AMG 55C F Body size 5C 5C 35C 45C 55C Thread type F G Conforms to ISO79-. Port size Applicable body size Size 5C 5C 35C 45C 55C /8 /4 3 3/8 4 / 6 3/4 Option 3 Description F Rubber material: Fluororubber H For medium air pressure (.6 MPa) J Drain guide /4 female threaded 4 R IN- reversal direction V Degreasing wash, 5 white vaseline 4 Drain piping and piping for a stop valve such as ball valve are required. 5 Only body/housing is degreasing washed. Auto drain 3 Description Drain cock (Without auto drain) C N.C. auto drain D N.O. auto drain 3 Refer to the table below for the combination between the draining specification and option. (Only one draining specification is selectable). Accessory Description B Bracket Bracket is included, (but not assembled). Auto Drain Specifications/Option Combinations : All draining specifications are available (including drain guide, J type). : N.C. auto drain (C type) is not available. : N.C. auto drain (C type) and N.O. auto drain (D type) are not available. F H R V F H R V : Not available Caution Water separator can remove water droplets, but it cannot remove moisture. Condition of inlet air Pressure:.7 MPa Temperature: 5ºC Relative humidity: % Liquid water content (Water droplet content): 5 g/m 3 (ANR) Compressed air flow: Rated flow of each model Water removal rate (%) = Removed water (Water droplet) (g) x Inflowed water (Water droplet) (g)

87 Water Separator Series AMG How to Order AMG65/85 AMG 65 4 Body size Size Thread type F G Port size Applicable body size Accessory B Option Description J Drain guide 4 female threaded 4 R IN- reversal direction 4 Drain piping and piping for a stop valve such as ball valve are required. Note) Element service indicator (symbol: T) is not available as an option because water deposits inside the indicator could lead to malfunctions. Auto drain D Description Bracket Bracket is included, (but not assembled). Description Drain cock (Without auto drain) 3 N.O. auto drain Refer to Auto Drain Specifications/Option Combinations. 3 Body size 85 is equipped with a ball valve (Rc3/8 female threaded). Auto Drain Specifications/Option Combinations : Available : Not available Auto drain specifications/option Auto drain specifications Option Applicable model D J R AMG65 AMG85 Auto drain specifications N.O. auto drain Drain guide 4 D J Option IN- reversal direction R Product Recommendation Stocked items for fast delivery Related Products AMG5C-FC AMG5C-FD AMG5C-FC AMG5C-FD AMG5C-FD AMG5C-F3C AMG5C-F3D AMG35C-F3 AMG35C-F3D AMG35C-F4C AMG35C-F4D AMG45C-F4D AMG45C-F6C AMG45C-F6D AMG55C-F6D AMG55C-FD AMG65C-FD AMG65C-F4D AMG85C-FD AMG85C-F4D Series AFF - Main Line Filters - page 67 Series AD4/6 - Auto Drain Valve - Series ADH4 - Heavy Duty Auto Drain Valve - Series GD4-- - Differential Pressure Gauge - Series AC - Modular Units - page 76 Specifications Fluid Compressed air Max. operating pressure. MPa Min. operating pressure.5 MPa Proof pressure.5 MPa Ambient and fluid temperature 5 to 6ºC Water removal rate 99% Element life years or when pressure drop reached. MPa With auto drain:. MPa (N.O. type) or.5 MPa (N.C. type) Model AMG5C AMG5C AMG35C AMG45C AMG55C AMG65 AMG85 Note) Rated flow [l/min (ANR)] Port size 8, 4 4, ,, ,,, Mass [kg] Note) Max. flow at.7 MPa. Max. flow varies depending on the operating pressure. Refer to Flow Characteristics and Maximum flow. Accessory Applicable model Bracket assembly (with mounting screws) AMG5C AMG5C AMG35C AMG45C AMG55C AMG65 AMG85 AM-BM AM-BM AM-BM3 AM-BM4 AM-BM5 BM56 BM57

88 Series AMG Water Separator Dimensions AMG5C to 55C Auto drain D I C: With auto drain (N.C.) D: With auto drain (N.O.) N K U T L M øv Bracket (Accessory) A E B H C IN J Drain cock Gray: N.C. Black: N.O. ø one-touch fitting 34 Combination of D: With auto drain (N.O.) and H: For medium air pressure M5 R G Maintenance space P Q Drain port S /4 female threaded Option J: Drain guide /4 female threaded F O Width across flats 4 /4 female threaded Model AMG5C AMG5C AMG35C AMG45C AMG55C Port size /8, /4 /4, 3/8 3/8, / /, 3/4 3/4, A B C D E F G 5 H I J K T Bracket related dimensions U L M V N O P Q R [mm] S

89 Water Separator Series AMG 3 Dimensions AMG Bracket (Accessory) Auto drain D: With auto drain (N.O.) 3 IN 4 Drain cock: Black ø one-touch fitting Option J: Drain guide /4 female threaded M5 Drain port 8 76 Dimensions AMG IN Bracket (Accessory) Auto drain D: With auto drain (N.O.) for AMG Maintenance space Width across flats 4 /4 female threaded 3/8 female threaded Maintenance space Drain Rc 3/8 female threaded

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to New Series Reduced wiring Series

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold Compact Electro-Pneumatic Regulator Series ITV How to Order For single unit and single unit for manifold ITV N Q Pressure range. MPa MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector N S L

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Series ITV1000/2000/3000

Series ITV1000/2000/3000 Electro-Pneumatic Regulator Series ITV// How to Order [Option] RoHS ITV S Model type type type Pressure range 5 MPa MPa.9 MPa CE compliant Nil Q CE compliant Note) Refer to pages, 5, and 6 for information

More information

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Electro-Pneumatic Regulator/Electronic Vacuum Regulator Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal // series are compatible with various input specifications, including

More information

4 Note 1) Value for communications type. (PROFIBUS DP)

4 Note 1) Value for communications type. (PROFIBUS DP) Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal Series // are compatible with various input specifications, including

More information

Electro-Pneumatic Regulator / Electronic Vacuum Regulator

Electro-Pneumatic Regulator / Electronic Vacuum Regulator Electro-Pneumatic Regulator / Electronic Vacuum Regulator Series Series Model Regulating pressure range Port size Page Series With a simplified high-density circuit board design, an extremely compact size

More information

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL SMC REULATOR ITV2 Electro-pneumatic Regulator Electronic Vacuum Regulator Series ITV Series ITV Series Model Regulating pressure range Port size With a simplified high-density circuit board design, an

More information

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL SMC REULATOR Electro-pneumatic Regulator Electronic Vacuum Regulator Series Series Series Model Regulating pressure range Port size With a simplified high-density circuit board design, an extremely compact

More information

Series ITV009. Compact Vacuum Regulator ITV IITV00 02 n. RoHS. How to Order

Series ITV009. Compact Vacuum Regulator ITV IITV00 02 n. RoHS. How to Order Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 6-8 www.cmafh.com 7 For single unit and single unit for manifold ITV 9 Pressure range 9 kpa Built-in One-touch

More information

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL Compact Electro-pneumatic Regulator Series For single unit and single unit for manifold Pressure range 9 Option. MPa. MPa.9 MPa kpa Option How to Order N Power supply voltage 24 VDC ±% 2 to VDC Option

More information

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M Compact Vacuum Regulator Series ITV RoHS For single unit and single unit for manifold ITV Pressure range kpa Power supply voltage 4 VDC ±% to VDC How to Order N Cable connector N Without cable connector

More information

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4 Compact Electro-Pneumatic Regulator Series ITV RoHS How to Order [Option] For single unit and single unit for manifold ITV N Pressure range. MPa. MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0. 000 Electro-Pneumatic Regulator Electronic Vacuum Regulator Series Series Model Set pressure range Port size Page Series 000 Controls air pressure steplessly in proportion to an electric signal. 0 05 to

More information

Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range

Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range 000 Electro-Pneumatic Regulator Series 000/000 Standard Specifications Symbol Straight type Right angle type Model Minimum supply pressure Maximum supply pressure Regulating pressure range Voltage Power

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)* 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator ITVH Series ARJ RoHS Maximum supply pressure Set pressure range Stability 3.0 MPa 0.2 to 2.0 MPa ARX AMR Stepless control of air

More information

Series 10-ZSE40A(F)/10-ISE40A

Series 10-ZSE40A(F)/10-ISE40A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information

Booster Regulator/Air Tank Increase factory air pressure by up to twice as much! Air-only operation requires no power supply, reduces

Booster Regulator/Air Tank Increase factory air pressure by up to twice as much! Air-only operation requires no power supply, reduces Booster Regulator/Air Tank Increase factory air pressure by up to twice as much! Air-only operation requires no power supply, reduces Boost pressure heat generation, and allows easy installation. 0.6 MPa

More information

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2 Series -PSE3 RoHS Remote Type 2-Color Display Digital Pressure Sensor Controller How to Order 2 3 4 5 Nil Options/Part No. L Input/Output specifications NPN2 output to 5 V output NPN2 output 4 to 2 m output

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/ISEA New M8 connector type RoHS IP65 Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously.

More information

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example E-P HYREG VY Series This hybrid regulator combines a regulator and a solenoid valve. Stepless control through electric signals Port sizes M5 to inches can be covered by combining an ultra-compact electro-pneumatic

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant -Colour Display Digital Pressure Switch Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 6 Fitting parts: Stainless steel 4 The sensor and fitting parts can

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

Ionizer (Nozzle type) Series IZN10

Ionizer (Nozzle type) Series IZN10 262 Series IZN0 / Nozzle type (Nozzle type) Series IZN0 RoHS Slim and compact: 6mm thickness. Nozzle selectable: Energy saving, large flow types and female threads for piping. ±0V ion balance: High frequency

More information

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth! Digital Pressure Switch Series ZSE1(F)/ISE1 Low profile 26.1mm 9.8 mm 13.5 mm 53.4 mm Reduced in depth! (Actual size) RoHScompliant Vertical mounting space reduced to approx.! 1 2 Position Detection Switch

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention

More information

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series) 3-Screen Display High-Precision Digital Pressure Switch New Added Variations! For general fluids IP65 2 outputs Analog output Setting is possible while checking Main screen the measured value. Sub screen

More information

Series ISA. Air Catch Sensor. For Detection of Work Presence

Series ISA. Air Catch Sensor. For Detection of Work Presence ED Bar graph for easy calibration The ED bar graph indicator in conjunction with the adjustment knob for the variable orifice allows for easy and correct calibrations. Over range (Red) Correct range (Green)

More information

Pressure Control Equipment

Pressure Control Equipment Control High-pressure Precision General Purpose Special Fluid/Deionized Water (Pure Water) Detection Control Control (General purpose, high-pressure, precision, vacuum, special fluid, deionized water (pure

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

Related vacuum products

Related vacuum products Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Authorised Distributors:- ASH & ALAIN INDIA PV LD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) el : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Digital Sensor Sensor

More information

Compact Proportional Solenoid Valve

Compact Proportional Solenoid Valve Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.

More information

Gateway Type Serial Transmission System

Gateway Type Serial Transmission System P99-EX-B Gateway Type Serial Transmission System P Maximum 8 point control (64 inputs/64 outputs) P Flexibility of manifold valve installation improved with 4 branch wiring Flexible installation and removal

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure High Precision, Series SE30/ISE30 How Order Option 1 Without lead wire Lead wire with connecr (Lead wire length: 2 m) L For positive pressure For vacuum/low pressure ISE30 01 SE30 01 25 M 25 M 01 R 1/8

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series VER000/000 Capable of actuating a cylinder and performing analog control of pressurization VER alone can be used to switch and actuate a cylinder and to

More information

2-Colour Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 How to Order Option 1 Without lead wire Nil Lead wire with connector (Lead wire length: 2m) L For positive pressure For vacuum/low

More information

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-580 www.cmafh.com VEF Port Port Applicable power Body size Body size Electro-pneumatic Proportional

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions Series ISE70/75/75H NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red Green

More information

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type Series ISE70/75/75H New NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

Low Differential Pressure Sensor ±1% F.S.

Low Differential Pressure Sensor ±1% F.S. CAT.ES100-49 A Low Differential Pressure Sensor Rated differential pressure range: 0 to 2 kpa Accuracy: ±1% F.S. LED display to confirm energization Series PSE550 Proof pressure: 65kPa Output: 1 to 5VDC

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch (F)/(H) Series Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor unit: Stainless steel 630 Fitting parts: Stainless steel 304 The sensor unit

More information

Remote Type Pressure Sensors Pressure Sensor Controllers

Remote Type Pressure Sensors Pressure Sensor Controllers CT.EUS1-56B-UK Remote Type Pressure Sensors Pressure Sensor Controllers Compact Pressure Sensor for Pneumatics PSE53 Multi-channel Digital Pressure Sensor Controller PSE2 Compact Pressure Sensor for Pneumatics

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Vacuum Equipment. Application. Series

Vacuum Equipment. Application. Series Equipment Series Application Page ejector In-line vacuum ejector Multistage ejector ejector with check valve Pad with check valve ejector for water soluble coolant removal ZH ZU ZL1/2 (Special order product)

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform

More information

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA CAT.ES- A for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA Three types of flow range. to l /min (PFD). to l /min (PFD). to l /min (PFD) Swept flow characteristics Tapered side seal

More information

2-colour Display High Precision Digital Pressure Switch

2-colour Display High Precision Digital Pressure Switch High Precision, -colour Display Digital Pressure Switch -colour Display High Precision Digital Pressure Switch Series ZSE/ISE Features djustable vacuum, positive and compound pressure switch with display.

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

25% reduction in volume * PB1013A/Air-operated type without foot

25% reduction in volume * PB1013A/Air-operated type without foot Process Pump (Diaphragm Pump) Series Compact, large capacity diaphragm pump, suitable for transferring and collecting a wide range of fluids Smaller, lighter, lmtop size Pa 5% reduction in volume * 11A/Air-operated

More information

Series PSE560 Pressure Sensor For General Fluids... 90

Series PSE560 Pressure Sensor For General Fluids... 90 Table of Contents Pressure Switch Selection Guide... Electronic Pressure Switch... Mechanical Pressure... Pressure Switch Application Example... Series SE/ISE High Precision, 2-color Display Digital Pressure

More information

Digital Flow Switch (Sensor Part) Operation Manual

Digital Flow Switch (Sensor Part) Operation Manual Digital Flow Switch (Sensor Part) Operation Manual For Air PF2A 50/5 Series PF2A 5/ 52/ 55 Series For Water PF2W /520/50 Series PF2W 5 Series For Water (High Temperature Fluid Type) PF2W T/520T/50T Series

More information

Sentronic PLUS 614 Series

Sentronic PLUS 614 Series Sentronic PLUS 64 Series Proportional Technology www.asco.com PRESSURE CONTROL: 64 SERIES SENTRONIC PLUS Sentronic PLUS Sentronic PLUS is a digitally operated pressure regulator valve. This valve accurately

More information

SV1000/2000/3000/4000

SV1000/2000/3000/4000 Decentralized Serial Wiring (GW System, Branches) Series EX00 Valve manifold and input unit manifold can be connected around the GW unit. ompatible with various protocols by replacing the GW unit. ompatible

More information

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES 76 ORDER GUIDE DP / configuration diagram Intermediate cable s Type Vacuum pressure Positive pressure Compound pressure Appearance An intermediate cable is required to connect the controller and the sensor

More information

E22 Proportional Technology

E22 Proportional Technology E22 Proportional www.numatics.com Pressure Control: E22 Proportional E22 Series Unlike SENTRONIC valves, E-Series valves operate with pulsed pilot valves which change the pressure in a control chamber.

More information

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1 Compact Flow Rate Sensor RAPIFLOW Resin Body Type Diversified High Performance High performance User-friendly Compatible CC-1235A 1 Diversified Five types of gases can be measured with just one unit Gas

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-pneumatic proportional valve: Flow type (VEF) Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical throttle valve function.) A model that is suitable

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT Compact Manometer Pressure measurements can easily be taken any time, anywhere. RoHS Compact and lightweight Portable type with a lightweight of only about 00 g (unit 50 g, battery 50 g) can also be held

More information

Intelligent Positioner

Intelligent Positioner Intelligent Positioner Construction The GEMÜ epos digital electro-pneumatic positioner detects the valve position via its external LongLife travel sensor. It has a solid housing with protected operating

More information

Electronic Pressure Switches

Electronic Pressure Switches 96 Pressure Switches Electronic Pressure Switches Electronic E.5 switching output Electronic pressure switches, High-Performance series with one switching output Outstanding overpressure protection (up

More information

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa 3-Screen Display High-Precision Digital Pressure Switch Air General Fluids 1.0 ISE70 ISE71 MPa/1.6 MPa 1.0 ISE70G ISE75G MPa/2.0 MPa 5.0 ISE76G ISE77G MPa/10 MPa It is possible to change the settings while

More information

Series IZS31. RoHS compliant

Series IZS31. RoHS compliant Ionizer 3 types of the sensors are available. Autobalance sensor [High-precision type] Adjusts ion balance near the workpiece to reduce any interference! New Autobalance sensor [Body-mounting type] Rapid

More information

ZSE30A(F) ISE30A. 105 to 105 kpa 10 to 105 kpa to 1.05 MPa. (0 to 50 C) ±0.2% F.S. ±1 digit. NPN/PNP open collector

ZSE30A(F) ISE30A. 105 to 105 kpa 10 to 105 kpa to 1.05 MPa. (0 to 50 C) ±0.2% F.S. ±1 digit. NPN/PNP open collector Pressure Switch Model Selection Table Self-contained Type ZSE20(F) ZSE30A(F) ISE30A ZSE40A(F) ISE40A ZSE10(F) Model Fluid Calibration method Set pressure range Power supply voltage 105 to 105 kpa 10 to

More information

EV2000 Series. Specifications. Descriptions Working fluid Max. working pressure Min. working pressure Withstanding pressure

EV2000 Series. Specifications. Descriptions Working fluid Max. working pressure Min. working pressure Withstanding pressure (solenoid valve type medium flow) High precision air pressure proportional enabling ultimate space saving of device. nic sensor Pressure JIS symbol Overview In this electro, feedback control with semiconductor

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics The ZSE3/E3 series is to be discontinued. We recommend you consider using the Z/E10 series or the

More information

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation Air Catch Sensor Non-Contact Sensor for Workpiece Placement Confirmation Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact type

More information

Electro-Pneumatic Devices Valves and Positioners. The Drive & Control Company

Electro-Pneumatic Devices Valves and Positioners. The Drive & Control Company Electro-Pneumatic Devices Valves and Positioners The Drive & Control Company Electro-Pneumatic Devices Dynamic precision from Rexroth Why choose Rexroth E/P s? Rexroth electro-pneumatic pressure control

More information

Glossary of Terms/Technical Information

Glossary of Terms/Technical Information Glossary of Terms/Technical Information Glossary of Terms A Absolute pressure Accuracy Analog output function P. 84 Auto preset function Auto shift function C Chattering Condensation Connection port size

More information

Intelligent Positioner

Intelligent Positioner Intelligent Positioner Construction The GEMÜ 1 µpos is a digital electro-pneumatic positioner for process valve control. Designed for simple, safe and quick use with valves with strokes < mm. The positioner,

More information

2-Color Display Digital Flow Switch

2-Color Display Digital Flow Switch -Color Display Digital Flow Switch Series Flow rate range:, 5, 5, l/min. Minimum unit setting:. l/min. (. l/min when the flow rate range is 5, 5, l/min.) Repeatability: ±%F.S. or less Grease-free Flow

More information

Sentronic LP IO-Link CLASS A 617 Series. Proportional Technology

Sentronic LP IO-Link CLASS A 617 Series. Proportional Technology Sentronic LP IO-Link CLASS A 617 Series Proportional Technology PROPORTIONAL PRESSURE CONTROL: 617 SERIES SENTRONIC LP IO-LINK VERSION ASCO NUMATICS Sentronic LP The Sentronic LP is a highly efficient

More information

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor.

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor. Ionizer 2 types of sensors are available. Rapid elimination of static electricity by a feedback sensor Continuously emits ions in accordance with the detected polarity of a workpiece. Supply pressure:

More information

Modular electrical and pneumatic automation system

Modular electrical and pneumatic automation system Modular electrical and pneumatic automation system Decentralised automatisation without control cabinet in protection type IP65 / IP67 Modular structure, also as central station with several decentralised

More information

Air preparation equipment. Supply of compressed air (1 or P) Exhaust (3, 5 or E, R) Silencer. Filter with manual water drain

Air preparation equipment. Supply of compressed air (1 or P) Exhaust (3, 5 or E, R) Silencer. Filter with manual water drain 13 Supply of compressed air (1 or P) Exhaust (3, 5 or E, R) Silencer Filter with manual water drain Filter with automatic water drain Pressure regulator with secondary exhaust Lubricator FRL filter/regulator/lubricatorassembly

More information

ER100 Series OUT. Specifications. Working fluid Working pressure range Control pressure range. Input voltage 2 wire Input impedance.

ER100 Series OUT. Specifications. Working fluid Working pressure range Control pressure range. Input voltage 2 wire Input impedance. Electro pneumatic regulator (nozzle flapper method) ER Series Variable controlling air pressure with electric signals ( to V DC / to ma DC) up to.mpa. Booster relay integrated and large flow rate. JIS

More information

Vacuum pumps/generators Small

Vacuum pumps/generators Small picompact10 Ejector with COAX patented technology. Reduced air-consumption with 30-50% compared to other ejector technologies. Easy to optimize vacuum performance with a varied selection of micro multi-stage

More information

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses Type 8644 can be combined with... Fully compatible with WAGO I/O Combination of Fieldbus, pilot valves and I/O modules High

More information

POSITIONERS and Controls for Complete Valve Automation

POSITIONERS and Controls for Complete Valve Automation CONTROLS A Division of AT Controls Pneumatic & Electro-Pneumatic POSITIONERS and Controls for Complete Valve Automation 1 SS SERIES SS Features Easy and quick auto-calibration Detecting RA (reverse acting)

More information

Vacuum Ejector with Solid State Timer

Vacuum Ejector with Solid State Timer Vacuum Ejector with Solid State Timer Incorporates solid state timer function for release valve control (Timer setting with PLC is unnecessary) Timing Chart OFF Suction command ON Suction output OFF ON

More information

DPS280 / DVS280 Series

DPS280 / DVS280 Series 1 2 3 4 5 6 7 8 Do not use corrosive or flammable gases or liquid with this product. Please use within the rated pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage

More information

EV2100V Series OUT VAC EV2100V. Specifications. 196kPa 196kPa Control pressure range Assured pressure range Power voltage Current consumption

EV2100V Series OUT VAC EV2100V. Specifications. 196kPa 196kPa Control pressure range Assured pressure range Power voltage Current consumption pneumatic regulator (solenoid type for vacuum) EVV Series JIS symbol EVV CAD DATA AVAILABLE. How to order Overview For electro pneumatic regulator EVV series, feedback control with semiconductor pressure

More information

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110 Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902

More information

Electronic Pressure Switches

Electronic Pressure Switches 96 Pressure Switches Electronic Pressure Switches Electronic E.6 2 switching outputs Electronic pressure switches, High-Performance series with two switching outputs Outstanding overpressure protection

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 751 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1469 ~ Sensor selection guide...

More information

Pressure & Flow Switches Sensors

Pressure & Flow Switches Sensors EMC-CAT-Sensor A -UK Pressure & Flow Switches Sensors Index ZSE/ISE 2-Colour Display Type Basic Pneumatic Digital Pressure Switch with high precision P. ZSE/ISE High Enclosure Pneumatic Digital Pressure

More information

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS AP1000-2000 Airpower positioners are a robust range of rotary or linear valve positioners in AP1000 electro-pneumatic (4-20mA), AP1200 pneumatic (3-15 psi) or AP2000 programmable smart type. Designed to

More information