25% reduction in volume * PB1013A/Air-operated type without foot

Size: px
Start display at page:

Download "25% reduction in volume * PB1013A/Air-operated type without foot"

Transcription

1 Process Pump (Diaphragm Pump) Series Compact, large capacity diaphragm pump, suitable for transferring and collecting a wide range of fluids Smaller, lighter, lmtop size Pa 5% reduction in volume * 11A/Air-operated type without foot Built-in solenoid valve only RoHS (Comparison with current series) Long service life 1.5 times Discharge 8 to ml/min Weight.11 kg 11A/Air-operated type without foot 66 mm 5 mm Application Examples Car washing machine Water/ detergents supply Printing machine Ink/solutions supply Machine tool Oil supply Reagents transfer in a pathological inspection device Low particle generation due to the diaphragm structure Flammable fluids can be used. () Body wetted parts Semiconductor/ LCD equipment DI water/solutions supply, Waste fluid collection Cleaning device DI water/ hydro-carbonic cleaning liquid supply Polypropylene Stainless steel 16 Analyzer for medical and biochemistry Reagents supply Devices related to solar cell/ secondary battery Electrolyte/ DI water supply Wetted materials Body: New PFA Diaphragm: Self-priming makes priming unnecessary. Sucks the liquid even if the pump is dry. Assembled in a clean room. Double packaged (11A) Easy to adjust the flow rate by the frequency 111A of ON/OFF of the solenoid valve. Built-in solenoid valve X F 11A and 11A are available up to 1 ml/min. Space saving () (P) (Comparison with current series) 7 mm 11A 11A 581

2 Process Pump Built-in Solenoid Valve/Air Operated 1A Series Ease of maintenance improved Piping connection port can be removed. The check ball can be replaced for maintenance easily. Discharge port < OUT> Smaller, lighter, 5% reduction in volume (/11A) The port can be removed by pulling out the clip. Check valve is resistant against foreign matter. Flow passage around the check ball is enlarged and improved for better resistance against foreign matter. Fluid passage area comparison 1.5 times (Comparison with current series) < IN> Suction port <AIR SUP> Air supply port Power consumption reduced.45 W.5 W CE-compliant (Built-in solenoid valve/111a) Longer life [Life is 1.5 times longer than the current product.] Longer life is realized by changing diaphragm to modified with better resistance. RoHS Mounting Variations Note) Mounting orientation: < OUT> port on top only Front mounting (with foot) Rear mounting Side mounting 11A only Series Variations Series 111A Discharge (ml/min) Material Body wetted parts Diaphragm Check valve Liquid contact seals Made to Order 11A Built-in solenoid valve 8 to 8 to 1 Polypropylene (PP) Stainless steel (SUS16) PP FKM 1/8 female thread Liquid contact seals SF7 With bracket which is interchangeable with previous type 11A 8 to 1 New PFA New PFA 1/8 female thread, 1/4" tube extension, With nut (LQ1/LQ) Note) Refer to page 65 for applicable fluids. 58

3 Series Air Operated/Wetted Materials: Fluoropolymer 11A Series Compact pump for DI water/chemical liquids For transferring and collecting DI water/chemical liquids Refer to page 65 for applicable fluids. Wetted materials: Body Diaphragm Assembled in a clean room. Double packaged New PFA Variation on fittings with nut (11A only) Insert bushing type (LQ1 fittings) (P) Triple seal construction Insert bushing Body Nut Main seal Tube 1 Triple seal construction Double stepped retaining design Nut Retightener Tube 1 Grip seal Body Application Examples Car washing machine Detergents transfer Analyzer (For medical/biochemical industry) Reagents transfer F Flare type (LQ fittings) X Printing machine Head cleaning liquid transfer Related to semiconductor/solar cell Cleaning liquid (e.g. DI water) collection Machine tool Coolant liquid collection Installation Examples Transferring and collecting liquid Transferring liquid by pressure Atomizing liquid Stirring liquid 58

4 Built-in Solenoid Valve 111A Air Operated 11A Process Pump (Diaphragm Pump) Body Wetted Parts: Polypropylene/Stainless Steel Built-in Solenoid Valve/Air Operated (External switching type) 1A Series 1 11 Built-in solenoid valve How to Order 1 A Thread type Type Nil Rc N NPT F G 1 1/8 1 Built-in solenoid valve only RoHS Made to Order (For details, refer to page 588.) Nil None X16 Liquid contact seals SF7 X47 With bracket which is interchangeable with previous type Only 11A, air-operated type is available to be made to order. Option Applicable actuation Nil B N Option None With foot With silencer When option is more than one, suffix in alphabetical order. For AIR EXH: AN1-M5 Built-in solenoid valve Foot AIR SUP AIR EXH AIR SUP/EXH 584 IN Built-in solenoid valve IN OUT OUT Specifications Model 111A 11A Built-in solenoid valve Main fluid suction/discharge port female thread Supply port female thread Pilot air Exhaust port M5 x.8 female thread Body wetted parts Polypropylene (PP), Stainless steel (SUS16) Diaphragm Material Check valve, Polypropylene (PP) Liquid contact seals FKM Discharge Note 1) 8 to ml/min 8 to 1 ml/min Note ) Average discharge pressure Pilot air pressure Air consumption Suction head Note 1) Noise Withstand pressure Diaphragm life (Reference) Fluid temperature Ambient temperature Recommended operating cycle Pilot air solenoid valve recommended Cv value Weight Mounting orientation Packaging Maximum viscosity Power supply voltage Power consumption to.6 MPa. to.7 MPa 4 L/min (ANR) or less Up to.5 m (dry state inside the pump) 64 db (A) or less (Option: With silencer AN1-M5) 1.5 MPa million cycles to 5 C (No freezing, heat cycle not applied) to 5 C (No freezing, heat cycle not applied) 1 to 1 Hz. Note ).18 kg.11 kg OUT port upside General environment 1 mpa s 4 VDC.5 W Silencer Each of the values above are for normal temperatures and clear water. For related products, refer to pages 6 to 6. Faulty sealing of the check valves or accumulation of dust may cause operation to stop, so slurry processing is not available. Refer to page 586 for maintenance parts. Note 1) The values given for discharge and suction head are for no piping. Values will depend on piping conditions. Note ) Applicable up to ml/min by using a solenoid valve with a large Cv value (Cv value of.5 or more). Note ) With low operating cycles, even a valve with a small Cv value can be operated.

5 Process Pump Built-in Solenoid Valve/Air Operated 1A Series Flow Rate Characteristics Built-in Solenoid Valve (111A) Cycle (1 Hz) Cycle (5 Hz) Air consumption (L/min [ANR]) Ratio of amount of discharge against clear water (%) SUP =.7 MPa SUP =.5 MPa SUP =.5 MPa SUP =. MPa SUP =.7 MPa SUP =.5 MPa SUP =.5 MPa SUP =. MPa Cycle (Hz) Viscosity (mpa s) Transfer is possible up to about 1 mpa s SUP =.7 MPa SUP =.5 MPa SUP =.5 MPa SUP =. MPa SUP =.7 MPa SUP =.5 MPa SUP =.5 MPa SUP =. MPa Cycle (7 Hz) Air Operated (11A) Cycle (1 Hz) Cycle (5 Hz) Cycle (7 Hz) Air Consumption: Built-in Solenoid Valve/Air Operated Air Consumption SUP =.7 MPa SUP =.5 MPa SUP =.5 MPa SUP =. MPa SUP =.7 MPa SUP =.5 MPa SUP =.5 MPa SUP =. MPa Viscosity Characteristics: Built-in Solenoid Valve/Air Operated Viscosity Characteristics (Flow rate correction for viscous fluids) SUP =.7 MPa SUP =.5 MPa SUP =.5 MPa SUP =. MPa Calculation of Air Consumption Selection from Viscosity Characteristic Graph Selection from Flow Rate Characteristic Graph Required specification example Find the pilot air pressure for a discharge rate of 6 ml/min and a discharge pressure of.15 MPa for builtin solenoid valve type. <The transferred fluid is clear water (viscosity of 1 mpa s, specific gravity of 1.) and solenoid valve cycle is 5 Hz.> When the total pump head is required instead of the discharge pressure, a discharge pressure of.1 MPa corresponds to a total pump head of 1 m. Selection procedure 1. First, mark the intersection point for a discharge rate of 6 ml/min and a discharge pressure of.15 MPa.. Find the pilot air pressure for the marked point. In this case, the point is between the discharge curves for.5 MPa and.5 MPa, and based on the proportional relationship to these lines, the pilot air pressure for this point is approximately.4 MPa. Find the air consumption for operation with a 5 Hz switching cycle and pilot air pressure of.5 MPa from the air consumption graph. Selection procedure 1. Look up from the 5 Hz switching cycle to find the intersection with SUP =.5 MPa.. From the point just found, draw a line to the Y-axis to find the air consumption. The result is approximately 1 L/min (ANR). 1. Flow rate characteristics are for clear water (viscosity of 1 mpa s, specific gravity of 1.), no piping for suction and discharge.. The amount of discharge differs greatly depending on properties (viscosity, specific gravity) of the fluid being transferred and operating conditions (pump head, transfer distance), etc. 1. The air consumption differs greatly depending on properties (viscosity, specific gravity) of the transferred fluid and operating conditions (pump head, transfer distance), etc. Required specification example Find the pilot air pressure and pilot air consumption for a discharge rate of 7 ml/min, discharge pressure of.15 MPa, and a viscosity of 15 mpa s. Selection procedure 1. First, find the ratio of the amount of discharge against clear water when viscosity is 15 mpa s from the graph to the left. It is determined to be 45%.. Next, the viscosity of 15 mp s and the discharge rate of 7 ml/min in the required specification example are converted to the amount of discharge for clear water. Since 45% of the clear water discharge is equivalent to 7 ml/min in the required specifications, 7 ml/min.45 = approximately 6 ml/min, indicating that a discharge rate of 6 ml/min is required for clear water.. Finally, find the pilot air pressure and pilot air consumption based on the flow rate characteristic graphs. Relationship between the kinematic viscosity Kinematic viscosity ν [m /s] = Viscosity µ [Pa s]/density [kg/m ] 1 cp = 1 mpa s = 1 - Pa s 1 cst = 1 mm /s = 1-6 m /s 585 (P) X F

6 1A Series Working Principle: Built-in Solenoid Valve/Air Operated Pump chamber Discharge port < OUT> Suction port < IN> Diaphragm Driving chamber Return spring Built-in solenoid valve (-port valve) Only 11A The 11A air-operated type is not equipped with a built-in solenoid valve. Prepare a -port solenoid valve separately. Air supply port <AIR SUP> Air exhaust port <AIR EXH> Piping and Operation: Built-in Solenoid Valve/Air Operated When air is supplied with the built-in solenoid valve turned ON (energized), air enters the driving chamber and the diaphragm moves to the left. Due to this movement, the fluid in the pump chamber passes through the upper check valve and is discharged to the discharge port < OUT>. When the solenoid valve is turned OFF (de-energized), the air inside the driving chamber is evacuated to air exhaust port <AIR EXH>, and the diaphragm is moved to the right by the return force of the return spring. Due to this movement, the fluid on the suction port < IN> passes through the check valve and is sucked into the pump chamber. The 111A transfers the fluid continuously by suction and discharge in turn by repeating ON/OFF of the built-in solenoid valve. The 11A air-operated type is operated by the ON/OFF operation of an external solenoid valve. Maintenance Parts Basically, it is not recommended to disassemble the process pump. However, if this is necessary, be sure to follow the instructions in the maintenance procedure. When carrying out this work, wear appropriate protective equipment. 1A Series Description 1A series 111A 11A Diaphragm kit KT-1A-9 KT-1A- Check valve kit Port set Packing kit KT-1A-1 KT-1A-7 Note) KT-1A-4 Foot kit Solenoid valve kit KT-1- SYJ14M-5H-Q KT-1A-4 Note) One of Nil, F or N is entered as a thread symbol. Piping diagram 111A Manual override pin Discharge port < OUT> 11A Discharge port < OUT> Be sure that the discharge port < OUT> is on top when the pump is mounted. Supply clean air that has passed through a filter or mist separator, etc., to the air supply port <AIR SUP>. Air that contains debris or drainage, etc., will have an adverse effect on the built-in solenoid valve, and will cause malfunction of the pump. Maintain the proper tightening torque for fittings or mounting bolts. Looseness can cause problems such as liquid or air leakage, while over-tightening can cause damage to threads or parts, etc. Suction port < IN> Solenoid valve lead wires Air supply port <AIR SUP> Air exhaust port <AIR EXH> (Silencer: Option) Recommended Valve () 11A SYJ54 Suction port < IN> Circuit example/built-in solenoid valve Operation 1. Connect air piping to the air supply port <AIR SUP>, and connect piping for transferred fluid to the suction port < IN> and the discharge port < OUT>.. Connect the solenoid valve lead wires to a 4 VDC power supply. Red is (+) and Black is ( ). (The 11A air-operated type must be equipped with a separate -port solenoid valve.). Using a regulator, set the pilot air pressure within the range of. to.7 MPa. By continuously turning the 4 VDC power ON/OFF, the fluid flows from the suction port < IN> to the discharge port < OUT>. The pump performs suction with its own power even without priming. Idle run of the pump Air supply port <AIR SUP> shall be minutes or less for the intake of the liquid. 4. To stop the pump turn OFF the 4 VDC power. Also, be sure to turn OFF the power when the discharge side is closed. If the pump is stopped for a long time, exhaust the air from the <AIR SUP> port. The manual override pin is used for manual operation when there is no electric power. Each time it is pressed, there is one reciprocal operation. For the 11A air-operated type, stop the -port solenoid valve, and be sure to discharge air from the pump. Although the pump can be stopped by closing the throttle installed in the discharge side, avoid stopping operation for a long time. If the valve opens/closes suddenly, surge is generated, shortening the pump life. When the tank for fluid suction side is empty, stop operating the pump immediately. Circuit example/ ON/OFF signal ON/OFF signal Air supply Air filter Regulator AIR SUP AIR EXH Process pump 111A OUT IN Throttle Strainer Air supply Air filter -port solenoid valve AIR SUP Regulator AIR EXH Process pump 11A OUT IN Throttle Strainer Transferred liquid Transferred liquid 586

7 Process Pump Built-in Solenoid Valve/Air Operated 1A Series Dimensions Built-in Solenoid Valve 111A 11 1 Mount with this surface up OUT Manual override pin x ø4.5 Mounting hole IN (P) X F Silencer: AN1-M5 (Option) 16 ø8 AIR SUP 8 1 x M4 x.7 Female mounting threads Thread depth 6 Lead wire length: Approx. 57 mm Foot (Option) AIR EXH M5 x.8 Thread depth 8 Air Operated 11A OUT x M4 x.7 Female mounting threads Thread depth x M4 x.7 Female mounting threads Thread depth Mount with this surface up x ø4.5 Mounting hole IN AIR SUP Foot (Option) Check the mounting orientation of the product. Mount the product vertically so that the < OUT> port faces upward. Also, secure all specified mounting positions when using the product. If the propagation of the vibration of the pump is not acceptable, insert vibro-isolating rubber when mounting. 587

8 1A Series Made to Order Please contact SMC for detailed dimensions, specifications and lead times. 1 Liquid contact seals SF7 (Perfluoropolyether rubber) 11 A 1 X16 X16 Thread type Nil N F Type Rc NPT G Seal material of the liquid contact parts is changed to SF7 (Perfluoropolyether rubber). Has better resistance against chemicals. Option Nil B C F Made to Order X16 Liquid contact seals SF7 Option None With foot With bracket which can be mounted to the back of the previous type With bracket which can be mounted to the foot at the back of the previous type e w q q e: O-rings (SF7) With bracket which is interchangeable with previous type X47 Bracket which is interchangeable with previous 1 series is mounted. 11 A 1 C X47 Thread type Nil N F Type Rc NPT G Made to Order X47 With bracket which is interchangeable with previous type Interchangeable bracket type C F Interchangeable bracket type With bracket which can be mounted to the back of the previous type With bracket which can be mounted to the foot at the back of the previous type With bracket which can be mounted to the back of the previous type: C x M4 x.7 With bracket which can be mounted to the foot at the back of the previous type: F 84 x ø

9 Female thread Process Pump (Diaphragm Pump) Wetted Materials: Fluoropolymer Air Operated (External switching type) 11A Series Tube extension Female thread/ Tube extension With nut The pump with nut is recommended when SMC fitting, LQ series, is used. Specifications How to Order Diaphragm material Material A P7 1 1 A S Connection method Connection method S With nut Note) Note) Refer to page 59 for details of the connection of the nut. Main fluid connection size Female thread 1 N1 F1 Tube extension P7 1/4" tube P7N extension P7F RoHS Rc1/8 NPT1/8 G1/8 Connection size in the air side Rc1/8 NPT1/8 G1/8 Main fluid Connection size connection size in the air side With nut 1S7 Rc1/8 With LQ1 1S7N NPT1/8 size nut 1S7F G1/8 S7 Rc1/8 With LQ S7N NPT1/8 size nut S7F G1/8 (P) X F With nut (LQ1 fittings) AIR SUP/EXH IN With nut (LQ fittings) OUT Material Model Main fluid suction/discharge port Pilot air supply/exhaust port Body wetted parts Diaphragm Check valve Liquid contact seals Discharge Note 1) Average discharge pressure Pilot air pressure Air consumption Suction head Note 1) Noise Withstand pressure Diaphragm life (Reference) Fluid temperature Ambient temperature Recommended operating cycle Pilot air solenoid valve recommended Cv value Weight Mounting orientation Packaging Maximum viscosity 11A female thread, 1/4" tube extension, With nut (LQ1/LQ) female thread New PFA, New PFA 8 to 1 ml/min to.4 MPa. to.5 MPa 15 L/min (ANR) or less Up to.5 m 71 db (A) or less.75 MPa 5 million cycles to 5 C (No freezing, heat cycle not applied) to 5 C (No freezing, heat cycle not applied) 1 to 5 Hz. Note ). kg OUT port upside Double clean package 1 mpa s Each of the values above are for normal temperatures and clear water. For related products, refer to pages 6 to 6. Faulty sealing of the check valves or accumulation of dust may cause operation to stop, so slurry processing is not available. Refer to page 59 for maintenance parts. Note 1) The values given for discharge and suction head are for no piping. Values will depend on piping conditions. Note ) With low operating cycles, even a valve with a small Cv value can be operated. 589

10 SMC SMC SMC SMC SMC SMC 11A Series Fittings compatible for the process pump with nut/11as. Product without nut (insert bushing), 1 piece nut removed, which is not necessary in cases when using the products with nut. LQ1 fittings E Union elbow P Panel mount union How to Order Fittings for Products with Nut (11AS) LQ1 E 1 Fitting type T Union tee Union U SN Applicable tube size Metric Nut (including insert bushing), 1 location removed Inch Size No. Applicable Applicable Reducing Size tube size (mm) tube (inch) Reducing 1 6 x 4 4 x A B 1/4" x 5/" /16" x 1/8" : Basic size : With reducer C 1/8" x.86" : Basic size : With reducer Note) Check the IN/OUT side fitting size and fitting type for selecting the fitting. LQ fittings E Union elbow P Panel mount union LQ E A Fitting type T Union tee Union U SN Nut, 1 location removed Applicable tube size Applicable Size tube size (inch) A 1/4" x 5/" Note) Check the IN/OUT side fitting size and fitting type for selecting the fitting. 1. For detailed specifications and Specific Product Precautions about fittings (LQ1, LQ), refer to Best Pneumatics No. 7.. Refer to the pamphlet High-Purity Fluoropolymer Fittings Hyper Fittings/LQ1, series Work Procedure Instructions (M-E5-1) or High Purity Fluoropolymer Fittings Hyper Fittings/Flare Type LQ series Fitting Procedure (M-E6-4) for connecting tube. (Downloadable from our website.) Ordering Example OUT side Tube size 4 x LQ1U-SN Union 11AS-1S7 Process pump 11AS-1S7 1 LQ1E1-SN LQ1E1-SN (Union elbow) 1 Union elbow Tube size LQ1U-SN (Union) 1 6 x 4 Note) Fittings ordered together with the IN side process pump will be shipped in a separate package. 59

11 Process Pump Air Operated 11A Series Flow Rate Characteristics: Air Operated (11A) Cycle (1 Hz).5 Cycle (5 Hz) SUP =.5 MPa SUP =.4 MPa SUP =. MPa SUP =. MPa SUP =.5 MPa SUP =.4 MPa SUP =. MPa SUP =. MPa (P) X F Air Consumption Air consumption (L/min [ANR]) Ratio of amount of discharge against clear water (%) Cycle (Hz) Viscosity Characteristics (Flow rate correction for viscous fluids) Viscosity (mpa s) Transfer is possible up to about 1 mpa s. SUP =.5 MPa SUP =.5 MPa SUP =. MPa Selection from Flow Rate Characteristic Graph Required specification example Find the pilot air pressure for a discharge rate of 4 ml/min and a discharge pressure of.15 MPa. <The transferred fluid is clear water (viscosity 1 mpa s, specific gravity of 1.) and solenoid valve cycle is 5 Hz.> When the total pump head is required instead of the discharge pressure, a discharge pressure of.1 MPa corresponds to a total pump head of 1 m. Selection procedure 1. First, mark the intersection point for a discharge rate of 4 ml/min and a discharge pressure of.15 MPa.. Find the pilot air pressure for the marked point. In this case, the point is between the discharge curves for. MPa and. MPa, and based on the proportional relationship to these lines, the pilot air pressure for this point is approximately.5 MPa. Calculation of Air Consumption Find the air consumption for operation with a 5 Hz switching cycle and pilot air pressure of.5 MPa from the air consumption graph. Selection procedure 1. Look up from the 5 Hz switching cycle to find the intersection with SUP =.5 MPa.. From the point just found, draw a line to the Y-axis to find the air consumption. The result is approximately 7.5 L/min (ANR). 1. Flow rate characteristics are for clear water (viscosity of 1 mpa s, specific gravity of 1.).. The amount of discharge differs greatly depending on properties (viscosity, specific gravity) of the transferred fluid and operating conditions (pump head, transfer distance), etc. Selection from Viscosity Characteristic Graph Required specification example Find the pilot air pressure and pilot air consumption for a discharge rate of 18 ml/min, discharge pressure of.15 MPa, and a viscosity of 15 mpa s. Selection procedure 1. First, find the ratio of the amount of discharge against clear water when viscosity is 15 mpa s from the graph to the left. It is determined to be 45%.. Next, the viscosity of 15 mp s and the discharge rate of 18 ml/min in the required specification example are converted to the discharge rate for clear water. Since 45% of the amount of clear water discharge is equivalent to 18 ml/min in the required specifications, 18 ml/min.45 = approximately 4 ml/min, indicating that a discharge rate of 4 ml/min is required for clear water.. Finally, find the pilot air pressure and pilot air consumption based on the flow rate characteristic graphs. Relationship between the kinematic viscosity Kinematic viscosity ν [m /s] = Viscosity µ [Pa s]/density [kg/m ] 1 cp = 1 mpa s = 1 - Pa s 1 cst = 1 mm /s = 1-6 m /s 591

12 11A Series Working Principle: Air Operated Pump chamber Discharge port < OUT> Suction port < IN> Diaphragm Driving chamber Return spring Air supply port <AIR SUP> Air exhaust port <AIR EXH> -port solenoid valve (Prepare it separately.) Piping and Operation: Air Operated When air is supplied with the external -port solenoid valve turned ON (energized), air enters the driving chamber and the diaphragm moves to the left. Due to this movement, the fluid in the pump chamber passes through the upper check valve and is discharged to the discharge port < OUT>. When the solenoid valve is turned OFF (de-energized), the air inside the driving chamber is evacuated to air exhaust port <AIR EXH>, and the diaphragm is moved to the right by the return force of the return spring. Due to this movement, the fluid on the suction port < IN> passes through the check valve and is sucked into the pump chamber. The fluid is transferred continuously by suction and discharge in turn by repeating ON/OFF of the built-in solenoid valve. Maintenance Parts Basically, it is not recommended to disassemble the process pump. However, if this is necessary, be sure to follow the instructions in the maintenance procedure. When carrying out this work, wear appropriate protective equipment. 11A Series Description 11A series Check valve kit KT-1A-51 Diaphragm kit KT-1A-5 Piping diagram Air supply port <AIR SUP> Discharge port < OUT> Be sure that the discharge port < OUT> is on top when the pump is mounted. Supply clean air that has passed through a mist separator etc., to the air supply port <AIR SUP>. When air needs additional purification, use a mist separator (AM series) and a micro mist separator (AMD series) together. Maintain the proper tightening torque for fittings or mounting bolts. Looseness can cause problems such as liquid or air leakage, while over-tightening can cause damage to threads or parts, etc. Suction port < IN> Recommended Valve () 11A SYJ54 Operation 1. Connect air piping to the air supply port <AIR SUP>, and connect piping for transferred fluid to the suction port < IN> and the discharge port < OUT>.. Set the pilot air pressure within the range of. to.5 MPa. If air is supplied or discharged intermittently using a -port solenoid valve, the pump operates, then after a short time the fluid flows from suction port < IN> to the discharge port < OUT>. The pump performs suction with its own power even without priming. Idle run of the pump shall be minutes or less for the intake of the liquid.. To stop the pump, stop the -port solenoid valve, and be sure to discharge air from the pump. Although the pump can be stopped by closing the throttle installed in the discharge side, avoid stopping operation for a long time. If the valve opens/closes suddenly, surge is generated, shortening the pump life. When the tank for fluid suction side is empty, stop operating the pump immediately. Circuit example/ ON/OFF signal -port solenoid valve Throttle Air supply Air filter AIR SUP Regulator AIR EXH Process pump 11A OUT IN Strainer Transferred liquid 59

13 Process Pump Air Operated 11A Series Dimensions Air Operated 11A AIR SUP With LQ1 fitting With LQ fitting (ø6.5) (1.) OUT 15 ø OUT (14) (149) (P) X F IN IN With nut (LQ1/LQ fittings) 1/4" tube extension 1. Check the mounting orientation of the product. Mount the product vertically so that the < OUT> port faces upward. Also, secure all specified mounting positions when using the product. If the propagation of the vibration of the pump is not acceptable, insert vibro-isolating rubber when mounting.. Open the sealed package inside a clean room. Products specified for clean room (11A) are sealed and double packaged inside a clean room. We recommend that the inner package should be opened inside a clean room or clean environment. 59

Compact Proportional Solenoid Valve

Compact Proportional Solenoid Valve Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04 Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application.

3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application. CC-1104A GHV Series 3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application. Main features Space-saving integrated structure Two solenoid valves

More information

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. For General Purpose /3 Port Valve Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. Wide variations Series For controlling pneumatic

More information

Process Valve/Series VN

Process Valve/Series VN For General Purpose /3 Port Valve Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. Wide variations Series VNA For controlling pneumatic

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to New Series Reduced wiring Series

More information

Fittings/Needle Valve/Tubing

Fittings/Needle Valve/Tubing CAT.ES70-7 D High Purity Fluoropolymer Fittings/Needle Valve/Tubing HYPER FITTING Series LQ V Quadruple seal construction (PAT.) Before tightening Nut Tubing support Insert bushing Tubing w e r Series

More information

Space saving, compact model available

Space saving, compact model available Compact Type High Purity ir Operated Chemical Liquid Valve Series RoHS LV Space saving, compact model available Compact type model is introduced as a new series to complement current series with integrated

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)* 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator ITVH Series ARJ RoHS Maximum supply pressure Set pressure range Stability 3.0 MPa 0.2 to 2.0 MPa ARX AMR Stepless control of air

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Series Port For Compressed Air and Air-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Cylinder actuation by external air he balance poppet

More information

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold Compact Electro-Pneumatic Regulator Series ITV How to Order For single unit and single unit for manifold ITV N Q Pressure range. MPa MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector N S L

More information

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4 Compact Electro-Pneumatic Regulator Series ITV RoHS How to Order [Option] For single unit and single unit for manifold ITV N Pressure range. MPa. MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector

More information

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL Compact Electro-pneumatic Regulator Series For single unit and single unit for manifold Pressure range 9 Option. MPa. MPa.9 MPa kpa Option How to Order N Power supply voltage 24 VDC ±% 2 to VDC Option

More information

Exclusively for air pressure system and air-hydro circuit control

Exclusively for air pressure system and air-hydro circuit control Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication Hand Valve VH Series VH0 Specifications VH0 Fluid Proof pressure Max. operating VH00/00/00 pressure VH0 Ambient temperature and operating fluid temperature Operating angle Lubrication Air.5 MPa.0 MPa MPa

More information

HN B G1/US B G2/US B G3

HN B G1/US B G2/US B G3 HN B G/US B G/US B G Compact direct acting, port solenoid valve air, water,, low vacuum (. x 0 Pa (abs)) CONTENTS Safety precautions port solenoid valve HNB NC (normally closed) type USB NC (normally closed)

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types Speed 2 Port Valve Series RoHS speed speed speed response response response 5 ms 9mm Width ±0.05 ms ±0.05 ms type VCH : : 5 ms * The response time is measured based on SMC test conditions. (Not guaranteed

More information

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example E-P HYREG VY Series This hybrid regulator combines a regulator and a solenoid valve. Stepless control through electric signals Port sizes M5 to inches can be covered by combining an ultra-compact electro-pneumatic

More information

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110 Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902

More information

Electro-Pneumatic Regulator / Electronic Vacuum Regulator

Electro-Pneumatic Regulator / Electronic Vacuum Regulator Electro-Pneumatic Regulator / Electronic Vacuum Regulator Series Series Model Regulating pressure range Port size Page Series With a simplified high-density circuit board design, an extremely compact size

More information

Vacuum Equipment. Application. Series

Vacuum Equipment. Application. Series Equipment Series Application Page ejector In-line vacuum ejector Multistage ejector ejector with check valve Pad with check valve ejector for water soluble coolant removal ZH ZU ZL1/2 (Special order product)

More information

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure Paddle Style For details about certified products conforming to international standards, visit us at www.smcworld.com. Flow switches, series IF detect and confirm liquid, generally used in fields such

More information

Series ITV1000/2000/3000

Series ITV1000/2000/3000 Electro-Pneumatic Regulator Series ITV// How to Order [Option] RoHS ITV S Model type type type Pressure range 5 MPa MPa.9 MPa CE compliant Nil Q CE compliant Note) Refer to pages, 5, and 6 for information

More information

Series VCHR. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

Series VCHR. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

Series AN /Series AMC

Series AN /Series AMC s/exhaust Cleaner / Noise reduction Nominal filtration rating (Reference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting 00 30 db (A) 00 µm 50 µm 5-0- Compact type

More information

Speed Controller with One-touch Fitting

Speed Controller with One-touch Fitting Speed Controller with One-touch Fitting Series Elbow Type Reduces labor time! Elbow Brass Stainless steel Electroless nickel plated Stainless steel 33 RoHS TMH y Easo t e us Push-lock type Larger handle

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Low Maintenance Filter

Low Maintenance Filter Low Maintenance Filter Series FN/FN4 No more element replacement! Our unique element construction with back-flushing capability The element of the filter is constructed of a series of grooved filter plates

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Low Maintenance Filter

Low Maintenance Filter Low Maintenance Filter FN/FN Series No more element replacement! Our unique element construction with back-flushing capability The element of the filter is constructed of a series of grooved filter plates

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0. 000 Electro-Pneumatic Regulator Electronic Vacuum Regulator Series Series Model Set pressure range Port size Page Series 000 Controls air pressure steplessly in proportion to an electric signal. 0 05 to

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1 Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH

More information

±0.18 F (±0.1 C) 88 lb (40 kg) 104 lb (47 kg) 152 lb (69 kg) 161 lb (73 kg) With heating function. Convenient functions

±0.18 F (±0.1 C) 88 lb (40 kg) 104 lb (47 kg) 152 lb (69 kg) 161 lb (73 kg) With heating function. Convenient functions Circulating Fluid Temperature Controller Thermo-chiller Lightweight/Compact Temperature stability Compact Type ±.18 F (±.1 C) HRS5 New New HRS6 (UL Standards) ( HRS3/6: Pending) RoHS HRS12/18/24 New HRS3

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Manifold Specifications

Manifold Specifications Specifications Specifications Base mounted VVFR-01 VVFR- VVFR-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal

More information

CVE2/CVSE2 CVE3/CVSE3

CVE2/CVSE2 CVE3/CVSE3 Overview This is a reliable 2, 3 port coolant valve with cylinder drive method. This valve for tool machine cutting oil or coolant control incorporates a metal seal to prevent the entry of cutting chips,

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

Miniature Regulator Series ARJ310

Miniature Regulator Series ARJ310 Miniature Regulator Series 30 Compact and lightweight (Main body 65 g) 8.3 Improved flow characteristics 0. 0. 0 00 00 300 400 500 Allows smaller mounting pitch 8.8mm 0-M5 30-0 Inlet pressure: MPa Accommodates

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M Compact Vacuum Regulator Series ITV RoHS For single unit and single unit for manifold ITV Pressure range kpa Power supply voltage 4 VDC ±% to VDC How to Order N Cable connector N Without cable connector

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Speed Controller with Indicator

Speed Controller with Indicator Speed Controller with Indicator The numerical indication of flow rate knob rotations reduces flow setting time and setting errors! Elbow Universal Brass Electroless nickel plated RoHS Stainless steel 1

More information

Air-Operated Double-Diaphragm. High Purity PTFE Pumps

Air-Operated Double-Diaphragm. High Purity PTFE Pumps Air-Operated Double-Diaphragm High Purity PTFE Pumps ULTRA High-Purity Series Ultra-High Purity Series was designed specifically for the Semiconductor Yamada s advantages come from years process of experience

More information

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL SMC REULATOR Electro-pneumatic Regulator Electronic Vacuum Regulator Series Series Series Model Regulating pressure range Port size With a simplified high-density circuit board design, an extremely compact

More information

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A 1 3 Port Air Operated Valve Series VTA301 JIS Symbol VTA 301 Indicate VO for manifold. Port size Specifications How to Order Without connection port (For manifold) 01 1/8 02 1/4 Option Fluid Air Operating

More information

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42) Paddle Style [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /4B to B. Wide range of

More information

Digital Flow Switch (Sensor Part) Operation Manual

Digital Flow Switch (Sensor Part) Operation Manual Digital Flow Switch (Sensor Part) Operation Manual For Air PF2A 50/5 Series PF2A 5/ 52/ 55 Series For Water PF2W /520/50 Series PF2W 5 Series For Water (High Temperature Fluid Type) PF2W T/520T/50T Series

More information

Speed Controller with One-touch Fitting

Speed Controller with One-touch Fitting Speed Controller with One-touch Fitting S Series Push-lock Type Reduces labor time! Easy to use Easy to lock Unlock Push-lock type Lock Improved tube insertion/removal Max. Insertion force: 30% (8 N) reduction

More information

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42) Series IF [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /B to B. Wide range of applicable

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features M1500 Plus Noninvasive Inline DSP Ultrasonic Flowmeter Accuracy ± 2% of Reading All wetted parts made of PFA Contamination free from ions or particles Minute flow measurements down to 4 ml/min* Easy configuration

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform

More information

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air Compact Direct Operated / Port Solenoid Valve for Water and Air 0/0/0: Port, 00/00: Port 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to

More information

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL SMC REULATOR ITV2 Electro-pneumatic Regulator Electronic Vacuum Regulator Series ITV Series ITV Series Model Regulating pressure range Port size With a simplified high-density circuit board design, an

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the

More information

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference)

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference) Digital Flow Switch for Deionized Water and Chemical Liquids PFD Series RoHS single controller can monitor the flow rate of different sensors. Body and New PF Tube Super PF Dust generation of particles/cc

More information

3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw)

3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw) Series VTA301 How to Order VTA 301 Indicate VO for manifold. Port size Without connection port (For manifold) 01 1/8 02 1/4 F N T Option B Rc G NPT NPTF Without bracket Foot bracket JIS Symbol Specifications

More information

Flow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note)

Flow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note) [Option] The flow switch, series IFW is used for detection and confirmation of the flow as a relaying device for the general water applications in some various equipment such as cooling water fixture in

More information

NAMUR Interface 5 Port Solenoid Valve

NAMUR Interface 5 Port Solenoid Valve NAMUR Interface 5 Port Solenoid Valve Series VFN000N 5 5 Specifications Valve Electrical entry Fluid Max. operating pressure Min. operating pressure Ambient and fluid temperature Lubrication Pilot operator

More information

1 1/4 (32A) to 2 (50A) added.

1 1/4 (32A) to 2 (50A) added. Coolant Valve 0.5 MPa.0 MPa.6 MPa RoHS /4 (3) to (50) added. Flow rate Cv (For 0.5 MPa specification) 3 4 5 0 0 30 Cv (kv) 40 5 million cycles or more Port size 70 6.5 (5.6) 3/8 (0), / (5).8 (0.) 3/4 (0)

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series 1 Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the

More information

AV2000-A/3000-A/4000-A/5000-A

AV2000-A/3000-A/4000-A/5000-A Soft Start-up Valve Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply Power consumption: 0.35 W * At 12/24 VDC

More information

20 Series. Simplify your pumping needs. s Adhesive Supply Servo Pump:

20 Series. Simplify your pumping needs. s Adhesive Supply Servo Pump: 20 Series Model 20-02-06 Adhesive Supply Servo Pump Simplify your pumping needs. s Model 20-02-06 Adhesive Supply Servo Pump allows excessive adhesive pressure to self-release back into the pump on shutdown

More information

EX Series. Electric Actuators for Ball and Butterfly Valves

EX Series. Electric Actuators for Ball and Butterfly Valves EX Series Electric Actuators for Ball and Butterfly Valves Next Generation Electrical Actuator Realization of Upgraded General-Purpose Actuators The modularization and the adoption of common parts have

More information

Coolant Valve. VNC Series. Cylinder actuation by pilot air

Coolant Valve. VNC Series. Cylinder actuation by pilot air oolant VN Series ir Operated/xternal Pilot Solenoid [Option] ylinder actuation by pilot air Wide selection of port and variations Threaded type (6 to ) lange type (3 to 80) Low water hammer or details,

More information

Impulse Lubricator. Standard Specifications

Impulse Lubricator. Standard Specifications Series 00/10 Intermittent discharge of small, constant amounts to the sliding parts Directly supplies a constant amount of oil just before the lubrication point Standard Specifications Model 1/8 (A) 1.0

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

Transmitters: Relay Valve VR4151/4152

Transmitters: Relay Valve VR4151/4152 Relay Valve VR4151/4152 Appropriate output sequences are affected according to the signal received from the mechanical valve. VR4151 VR4152 Precautions Be sure to read before handling. Refer to pages 5-11-2

More information

5 Port Air Operated Valve. How to Order. Port size. (A, B port) R port of VFA3 70 is 1/4.

5 Port Air Operated Valve. How to Order. Port size. (A, B port) R port of VFA3 70 is 1/4. Port Air Operated Valve Series VFA000 How to Order Body ported single solenoid Foot bracket VFA22 Port size (P, A, B port) 0 8 4 R, R2 port are /8. F Thread type (Including pilot port) F N T Rc G NPT NPTF

More information

Power Valve Precision Regulator

Power Valve Precision Regulator Power Valve Precision Regulator VEX Series High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air

More information

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation Air Catch Sensor Non-Contact Sensor for Workpiece Placement Confirmation Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact type

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated /3 Port Solenoid Valve & Check Valve VCH Series VCH4/4: Port VCH40: 3 Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve [Option] VCH40 Series Stable responsiveness Response

More information