SV1000/2000/3000/4000
|
|
- Madison Maxwell
- 5 years ago
- Views:
Transcription
1 Decentralized Serial Wiring (GW System, Branches) Series EX00 Valve manifold and input unit manifold can be connected around the GW unit. ompatible with various protocols by replacing the GW unit. ompatible with -digital-outputs ( points x branches) and -digital-inputs ( points x branches). GW unit, Input unit manifold: Valve manifold including SI unit: IP SI unit GW unit Input unit SI unit VQ Position Detection Switch Flow Sensor Pressure ontrol Pressure Sensor Input unit SV000/000/000/000 Alphabetical Index Length Measuring/ ounter educed-wiring Fieldbus System Static Electricity Elimination Equipment
2 Decentralized Serial Wiring (GW System, Branches) Series EX00 GW Unit How to Order GW Unit EX00 G DN ommunication protocol DN DeviceNet PA POFIB DP MJ -Link EN EtherNet/IP GW Unit Specifications ommunication Model Applicable system ommunication speed onfiguration file Note ) I/O occupation area (Inputs/Outputs) Terminating resistor Protocol Version Note ) Power For unit supply voltage For sensors For valve Internal current consumption (Unit) Number of inputs onnection input device Supply voltage Supply current Number of outputs onnection output device Supply voltage Supply current Output Input Branch cable length Operating humidity range Environment EX00-GDN EX00-GPA EX00-GMJ EX00-GEN DeviceNet POFIB DP -Link EtherNet/IP elease.0 DP-V0 Ver..0 elease.0 k/0 k/00 kbps 9. k/9. k/. k/ 9. k/. k/00 k/. M/ M/ M/ Mbps GSD file k/ k/. M/ M/0 Mbps 0M/00 Mbps EDS file EDS file 9/9 / / ( stations, remote device station) / Built into the unit Not provided Not provided (Switch setting) to VD (Supplied by DeviceNet VD±0% circuit, 0 ma or less) VD±0% VD±0%/ % 00 ma or less (GW unit) inputs ( inputs x branches) The EX00 series input unit manifold (connection from communication port A to D) VD Max.. A (Max. 0. A per branch) outputs ( outputs x branches) The EX00 series SI unit manifold (connection from communication port A to D) VD Max..0 A (Max. 0. A per branch) m or less between connected devices (total extension 0 m or less) Operating: to Stored: to 0 (with no freezing and condensation) Operating, Stored: to %H (with no condensation) 000 VA for minute between whole live part and enclosure MΩ or more (00 VD mega meter) between whole live part and enclosure E marking, UL (SA) 0 g Accessory: Waterproof cap (for M connector socket) EX00-AWTS ( pcs.) EX00-AWTS ( pcs.) EX00-AWTS ( pcs.) EX00-AWTS ( pcs.) Note ) Please note that the version is subject to change. Note ) Each file can be downloaded from SM s website ( Note ) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SM s website (
3 IN OUT B LINK MS NS SOL PW SOL L UN L E. PE IN OUT B LAN PW LINK 00 MS NS UN SOL BF DIA PE Decentralized Serial Wiring (GW System, Branches) Series EX00 GW Unit Dimensions/Parts Description EX00-GDN(DeviceNet ) ommunication connector (M, pins, plug) Power supply connector Note ) Note ) Marker: EX00-GMJ(-Link) LINK IN (M, pins, plug) LINK OUT (M, pins, socket) Power supply connector Note ) VD Note ) Marker: Bus adapter OM A 0 0 OM B GATEWAY UNIT EX00 SEIES VD OM A OM B OM OM D GATEWAY UNIT EX00 SEIES OM OM D PE Switch protective Switch protective cover EX00-GPA(POFIB DP) cover x M (mounting hole) ommunication x M (mounting hole) connector M M Ground terminal (M, pins, plug Ground terminal reverse key) 0 0 BN-WH (Made by PHOENIX ONTAT). Switch protective cover x M (mounting hole) M Ground terminal BN-WH (Made by PHOENIX ONTAT). 9. or less ommunication connector (M, pins, socket reverse key) Power supply connector Note ) Note ) EX00-GEN(EtherNet/IP ) ommunication connector (M, pins, socket type D) Power supply connector Note ) VD Note ) OM A 0 OM B GATEWAY UNIT EX00 SEIES VD OM A OM B OM OM D 0 GATEWAY UNIT EX00 SEIES OM OM D PE 0 x M (mounting hole) M Ground terminal Marker: BN-WH (Made by PHOENIX ONTAT) Switch protective cover Marker: BN-WH (Made by PHOENIX ONTAT) Position Detection Switch Flow Sensor Pressure ontrol Pressure Sensor educed-wiring Fieldbus System Note ) Power supply connector specification (M, pins, plug) Note ) specification (M, pins, socket) Alphabetical Index Length Measuring/ ounter Static Electricity Elimination Equipment
4 VD/0mA/ VD/0mA/ VD/0mA/ EX00-IE VD/0mA/ IP ODE IP ODE IP ODE IP ODE VD/0mA/ VD/0mA/ VD/0mA/ IP ODE IP ODE Series EX00 Input Unit Manifold How to Order Input Manifold EEX00 IB onnector type E M connector T M connector M M, M mixed E Stations station stations How to Order Input Block EX00 IE Block type M connector, inputs, PNP specifications M connector, inputs, NPN specifications M connector, inputs, PNP specifications M connector, inputs, NPN specifications M connector, points integrated type, PNP specifications M connector, points integrated type, NPN specifications For options, refer to pages 0 to. Input unit (M connector) (M connector) DIN rail End block points integrated type input block (M connector) How to Order Input Unit Manifold [Ordering Example] When ordering an input unit manifold, enter the Input manifold part no. + part no.. The Input unit, End block and DIN rail are included in the input manifold. efer to the indications below. Block part no. entry Input unit side End block side Example ) M input block only Input manifold Input unit side EEX00-IB-E ( set) EX00-IB VD/0mA INPUT IP ODE SEIALNo. EX00-IE VD/0mA IP ODE SEIALNo. EX00-IE VD/0mA IP ODE SEIALNo. EX00-IE ( sets) EEX00-IB-E... set EX00-IE... sets End block side Example ) M input block only Input manifold Input unit side EEX00-IB-T ( set) EX00-IB VD/0mA INPUT IP ODE SEIALNo. VD/0mA VD/0mA VD/0mA VD/0mA EX00-IE ( sets) EEX00-IB-T... set EX00-IE... sets End block side Input unit side EX00-IB VD/0mA INPUT IP ODE SEIALNo. Input unit side EX00-IB VD/0mA INPUT IP ODE SEIALNo. EX00-IE VD/0mA IP ODE SEIALNo. VD/0mA/ VD/0mA/ VD/0mA/ VD/0mA/ VD/0mA/ Input manifold EEX00-IB-E ( set) VD/0mA/ ( sets) Input manifold EEX00-IB-E ( set) EX00-IE ( set) ( sets) EEX00-IB-E... set... sets End block side EEX00-IB-E... set EX00-IE... set... sets End block side Example ) M, M mixed Input manifold Input unit side EEX00-IB-M ( set) EX00-IB VD/0mA INPUT IP ODE SEIALNo. VD/0mA VD/0mA ( sets) ( sets) EEX00-IB-M... set... sets... sets End block side Note) Since the points integrated type input block is equivalent to the length of four stations on an M input block, pay attention to the number of stations on an input manifold. When an input block layout becomes complicated, indicate in the input unit manifold specifications sheet.
5 Decentralized Serial Wiring (GW System, Branches) Series EX00 Input Unit Specifications Model Internal current consumption Number of inputs onnection block Input onnection block stations Environment Operating humidity range Input Block Specifications EX00-IB 00 ma or less inputs The EX00 series input block (mixed combination is possible) -input, input block: Max. stations -input, input block: Max. stations Operating: to Stored: to 0 (with no freezing and condensation) Operating, Stored: to %H (with no condensation) 000 VA for minute between whole live part and enclosure MΩ or more (00 VD mega meter) between whole live part and enclosure E marking, UL (SA) 00 g (Input unit + End block) Model EX00-IE EX00-IE EX00-IE EX00-IE Input type PNP sensor input NPN sensor input PNP sensor input NPN sensor input PNP sensor input NPN sensor input Number of inputs inputs inputs Input Input device supply voltage Input device supply current ated input current Display VD Max. 0 ma/input unit manifold Approx. ma Green LED (Lights up when power is turned ON.) onnector on the input device side M connector ( pins, plug) M connector ( pins, plug) M connector ( pins, plug) Environment Operating humidity range Operating: to Stored: to 0 (with no freezing and condensation) Operating, Stored: to %H (with no condensation) 000 VA for minute between whole live part and enclosure MΩ or more (00 VD mega meter) between whole live part and enclosure E marking, UL (SA) Accessory: Waterproof cap (for M connector socket) (for M connector socket) 0 g EX00-AWES ( pcs.) 0 g EX00-AWTS ( pcs.) g EX00-AWES ( pcs.) Note) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SM s website ( Alphabetical Index Position Detection Switch Flow Sensor Pressure ontrol Pressure Sensor educed-wiring Fieldbus System Length Measuring/ ounter Static Electricity Elimination Equipment
6 INPUT IP ODE SEIAL NO. VD/0mA INPUT IP ODE SEIAL NO. VD/0mA VD/0mA IP ODE VD/0mA IP ODE VD/0mA/ VD/0mA/ TYPE TYPE IP ODE VD/0mA IP ODE VD/0mA/ TYPE VD/0mA VD/0mA/ TYPE IP ODE VD/0mA/ TYPE VD/0mA VD/0mA/ TYPE IP ODE VD/0mA VD/0mA/ TYPE IP ODE VD/0mA/ TYPE VD/0mA IP ODE VD/0mA Series EX00 Input Unit Manifold Dimensions/Parts Description (M) only (M, pins, plug) onnector for input device connection (M, pins, socket) (Pitch) P = DIN rail 9. L L (ail mounting pitch:.) L (L) Marker: BN-WH (Made by PHOENIX ONTAT). EX00-IB (.). 9. Stations ail length L Mounting pitch L Manifold length L L (mm).... (M) only (M, pins, plug) onnector for input device connection (M, pins, socket) (Pitch) P = 0 DIN rail 0. Position indicator LED L L (ail mounting pitch:.) L (L) Marker: BN-WH (Made by PHOENIX ONTAT). EX00-IB (.)..9 Stations ail length L Mounting pitch L Manifold length L L (mm).. 0..
7 Decentralized Serial Wiring (GW System, Branches) Series EX00 Input Unit Manifold Exploded View w r a q Parts List No. Description Part no. For standard Note Input unit (M connector) (M connector) (M connector) points integrated type End block DIN rail EX00-IB EX00-IE EX00-IE EX00-IE EX00-EB VZ PNP specifications... :, NPN specifications... : PNP specifications... :, NPN specifications... : PNP specifications... :, NPN specifications... : : No. based on L dimension (efer to the table below.) How to add input block stations z Loosen the screws ( places) that hold the end block. x Separate the blocks at the locations where stations are to be added. c Attach the additional blocks to the DIN rail, and connect the blocks so that they fit together securely. v While holding the blocks together so that there are no gaps between them, secure them to the DIN rail by tightening the screws. Note: Be sure to tighten the round head combination screw with the prescribed tightening torque. (0. N m) y e a t Position Detection Switch Flow Sensor Pressure ontrol Pressure Sensor educed-wiring Fieldbus System Static Electricity Elimination Equipment DIN ail L Dimension [mm] M input block (m) Stations onnector type For M (m + n = to ) onnector type For T (n = to ) M input block (n) onnector type For E (m = to ) L dimension No. L dimension No. L dimension Length Measuring/ ounter Alphabetical Index
8 Series EX00 SI Unit SV000/000/000/000 How to Order SI Unit EX00 S00 Applicable solenoid valve: Series SV PW OM For options, refer to pages 0 to. D D D D D D SI Unit Specifications (EX00-S00) Model Internal current consumption Number of outputs Output type EX00-S00 00 ma or less outputs NPN (Positive common) Positive common compatible Output onnection block Solenoid valve (single, double) elay output module ( ouput, outputs) Environment onnection block stations onnection block supply current Operating humidity range Double solenoid valve, relay output module ( outputs): Max. stations Single solenoid valve, relay output module ( output): Max. stations Max. 0. A IP Operating: to Stored: to 0 (with no freezing and condensation) Operating, Stored: to %H (with no condensation) 000 VA for minute between whole live part and enclosure MΩ or more (00 VD mega meter) between whole live part and enclosure E marking, UL (SA) g Accessory: Waterproof cap (for M connector socket) EX00-AWTS ( pc.) Note) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SM s website ( SI Unit Dimensions/Parts Description EX00-S (M, pins, socket).. 9 (M, pins, plug)
9 EX00 series EX00 series Decentralized Serial Wiring (GW System, Branches) Series EX00 SI Unit SY000/000 VQ000/000/000 Note) SY000/000, VQ000/000/000, S000 are not yet UL-compatible. SI Unit Specifications (EX00-Q 0 ) Output specifications onnection block stations S000 How to Order SI Unit EX00 Q 0 0 Applicable solenoid valve: Series SY/VQ/S000 Output specifications 0 NPN (Positive common) PNP (Negative common) SI unit type For without EX9 output block For EX9 output block mounting For options, refer to pages 0 to. Model EX00-Q00 EX00-Q0 EX00-Q00 EX00-Q0 Internal current consumption 00 ma or less Number of outputs points Output type NPN (Positive common) PNP (Negative common) NPN (Positive common) PNP (Negative common) onnection block Positive common compatible Positive common compatible Negative common compatible Negative common compatible Note ) Output block, power block Output block, power block Solenoid valve (single, double) Solenoid valve (single, double) Solenoid valve (single, double) Solenoid valve (single, double) Double solenoid valve: Max. stations Single solenoid valve: Max. stations Double solenoid valve, output block: Max. stations Single solenoid valve: Max. stations Power block is not included. onnection block supply current Max. 0. A IP Operating: to Stored: to 0 (with no freezing and condensation) Environment Operating humidity range Operating, Stored: to %H (with no condensation) 000 VA for minute between whole live part and enclosure MΩ or more (00 VD mega meter) between whole live part and enclosure E marking, UL (SA) 0 g Accessory: Waterproof cap (for M connector socket) EX00-AWTS ( pc.) Note ) For details of output block and power block, refer to page 0. Note ) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SM s website ( Position Detection Switch Flow Sensor Pressure ontrol Pressure Sensor educed-wiring Fieldbus System SI Unit Dimensions/Parts Description EX00-Q 0 PW OM EX00-Q 0 SI UNIT PW OM EX00 series x M (mounting hole) Static Electricity Elimination Equipment (M, pins, socket) (M, pins, plug) (M, pins, socket) (M, pins, plug) Length Measuring/ ounter Alphabetical Index. 9
10 Series EX00 Options Output block/ Power block Features: Possible to retrofit to the valve manifold, using the unused points. -output/-output block (M connector) Positive/Negative common available as standard. Possible to drive by up to 0. A per a point. (EX9-OEP ) Output block Power block How to Order Output Block EX9 OE T Output specifications PNP (Negative common) NPN (Positive common) Power supply type Internal power supply method T (for low-wattage load) Integrated power supply method P (for high-wattage load) Note) Note) equired to connect with a power block. How to Order Power Block EX9 PE Option/Part No. Description Part no. Note Waterproof cap efer to page. EX00-AWTS When ordering separately: 0 pcs. Power cable with efer to page, EX9-A - connector Order separately. SI Unit Part No. SI unit part no. Output Applicable model EX00-Q00 EX00-Q0 PNP (Negative common) NPN (Positive common) EX9-OET, EX9-OEP EX9-OET, EX9-OEP Option/Part No. Description Waterproof cap able with connector EX9-A - for output entry Power block EX9-PE Applicable model Part no. OET OEP EX00-AWTS Note efer to page. Order separately: 0 pcs. efer to page. Order separately. efer to the right page. Order separately. 0
11 Decentralized Serial Wiring (GW System, Branches) Series EX00 Output Block Specifications Model EX9-OET EX9-OET EX9-OEP EX9-OEP Output connector Internal current consumption Output type Number of outputs Power supply method Output Output device supply voltage Output device supply current Display Environment onnector on the output device side Operating humidity range Internal power supply method Max. ma/point (.0 W/point) Note) M connector ( pins) 0 ma or less PNP (Negative common) NPN (Positive common) PNP (Negative common) NPN (Positive common) Note) The rated load current varies due to the output capability of the SI unit when connected to EX00. outputs VD Yellow LED (Lights up when power is turned ON.) M connector ( pins, plug) IP 0 to 0 to %H (with no condensation) 00 VA for min. between whole external terminal and FG 0 MΩ or more (00 VD) between whole external terminal and FG E marking, UL (SA) 0 g Integrated power supply method (Power block: supplied from EX9-PE) Max. 0. A/point ( W/point) Power Block Specifications Model EX9-PE onnection block onnection block stations Output block (for high-wattage load) Output block: Max. stations Power supply for output and internal control Supply current Environment Power supply voltage Internal power consumption Operating humidity range. to. VD 0 ma or less Max.. A (When using with.0 to. A, the ambient temperature should not exceed 0, and do not bundle the cable.) IP 0 to 0 to %H (with no condensation) 00 VA for min. between whole external terminal and FG 0 MΩ or more (00 VD) between whole external terminal and FG E marking, UL (SA) 0 g Accessory: Waterproof cap (for M connector socket) EX00-AWTS ( pc.) Note) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SM s website ( Alphabetical Index Position Detection Switch Flow Sensor Pressure ontrol Pressure Sensor educed-wiring Fieldbus System Length Measuring/ ounter Static Electricity Elimination Equipment
12 Series EX00 Options Output Block Dimensions Power Block Dimensions. 0. PW. 9.. onnector for output device connection (M, pins, socket). 9.. Power supply connecor (unused) Power supply input connector (M, pins, plug, reverse keyway).... We sell this product individually. Please place an order separately. You are requested to connect it to an SI unit and a valve manifold. When using the output block only (valve manifold is unused.), place an order for an end plate ( EX9-EA0) separately for connection. efer to the operation manual for connection, wiring, installation, option and cable, etc. End plate EX9 EA x M (mounting hole)
Gateway Type Serial Transmission System
P99-EX-B Gateway Type Serial Transmission System P Maximum 8 point control (64 inputs/64 outputs) P Flexibility of manifold valve installation improved with 4 branch wiring Flexible installation and removal
More informationFieldbus System (Output device for driving 5 port solenoid valves)
Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to
More informationFieldbus System (Gateway Decentralized Type)
Fieldbus System (Gateway Decentralized Type) * * Except the SY, VQC and S0700 valves GW Unit which supports PROFINET added. New M connector type Input Unit added. Decentralized valve installation Valves
More informationSeries ITV1000/2000/3000
Electro-Pneumatic Regulator Series ITV// How to Order [Option] RoHS ITV S Model type type type Pressure range 5 MPa MPa.9 MPa CE compliant Nil Q CE compliant Note) Refer to pages, 5, and 6 for information
More informationSMC guide to ATEX compliant products
SMC guide to ATEX compliant products P-E13-23A A ATEX Directive Directive 94/9/EC Equipment and Protective Systems intended for use in potentially Explosive Atmospheres Outline of ATEX directive Since
More informationSelect from 3 product types and 14 protocols.
Fieldbus System Select from 3 product types and 14 protocols. * Some protocols are not UL-compliant. Type 1 Type 2 Type 3 Output type for solenoid valves Gateway type Integrated input-output type CAT.E02-27A
More informationFieldbus System Variations
Fieldbus System Variations IP67/65 specification models I/O separated type Valve outputs only Inputs only Gateway-type valve outputs only inputs only I/O integrated type Valve outputs with multiple I/O
More informationElectro-Pneumatic Regulator Electronic Vacuum Regulator
Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring
More informationSeries ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold
Compact Electro-Pneumatic Regulator Series ITV How to Order For single unit and single unit for manifold ITV N Q Pressure range. MPa MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector N S L
More informationElectro-Pneumatic Regulators. Electronic Vacuum Regulators
Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators
More informationReduced-wiring Fieldbus System (Serial Transmission)
Best Pneumatics 1 Fieldbus System Variations P.2040 Applicable Valve Series P.2042 SV P.2042 SZ P.2042 SY NEW P.2043 SY P.2044 SYJ P.2045 SJ P.2045 VQC P.2046 SQ P.2046 VQ P.2047 VQZ P.2047 P.2048 Reduced-wiring
More informationElectro-Pneumatic Regulators. Electronic Vacuum Regulators
Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to New Series Reduced wiring Series
More informationElectro-Pneumatic Regulators. Electronic Vacuum Regulators
Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators
More informationSV F. Series SV SV SZ SYJ. Series EX500 Decentralized Serial Wiring. How to Order Valve Manifold Assembly. How to Order Solenoid Valves
side EX00 ecentralized Serial Wiring How to Order Valve Manifold Assembly Ordering example (000) Manifold S-WSAW-0B-C ( set) ouble solenoid 00-F ( sets) Single solenoid 00-F ( sets) side PW COM S-WSAW-0B-C
More informationFeatures General Information ompact, easy to install, reliable, serial bus compatible... Easy to meet system design needs Full flow capacity allows di
Features...3 Valves with Operators... 4-5 Head & Tail Sets and Intermediate Air Supply Modules...6 Head & Tail Sets with Serial Bus ommunications...7 How To Order...8 Replacement Kits...9 Interface 2000
More informationElectro-Pneumatic Regulator/Electronic Vacuum Regulator
Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal // series are compatible with various input specifications, including
More informationSingle Valve/Sub-plate Type IP67 Compliant 90-SV Series
Single Valve/Sub-plate Type IP7 Compliant -SV Series SV 00 W U aterial restriction Series -SV000 -SV000 Thread type c F G N NPT T NPTF A B SOL.a SOL.a Type of actuation position single (EA) (P)(EB) position
More informationD-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector
Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),
More information4 Note 1) Value for communications type. (PROFIBUS DP)
Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal Series // are compatible with various input specifications, including
More informationVQ1000. How to Order Manifold. Kit type
- - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold
More informationNew Concept Connector Type Manifold
New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.
More informationSI unit for AS-Interface EX250-SAS#
PRODUCT NAME SI unitfor AS-Interface MODEL / Series / Product Number EX250-SAS# Table of Contents Safety Instructions 2 Product Outline 8 Model Indication and How to Order 9 Summary of Product elements
More informationSYSMAC Transistor Remote Module
9 SYSMAC Transistor Remote Module Block and Transmission Capability in One Module 1 Two-conductor cable communications available using Omron Wired Remote I/O Master Modules (C200H-RM201 and C500-RM201)
More informationI N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications
I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000
More informationD-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000
D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details
More information10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection
Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection
More information42 Series MAConnect TM. 42 Series Plug-In Manifold
42 Series MAConnect TM 42 Series Plug-In Manifold Specifications 42 Series Valve Operating Data Fluids: Lubrication: Safe Operating Temperature Range: Pressure Range: Electrical: Air or Inert Gas Not Required.
More informationSG-B1 SERIES / SG-A1 SERIES
643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &
More informationBase Mounted Plug-in Unit
For details about certified products conforming to international standards, visit us at www.smcworld.com. Plug-in Unit SI unit COM N VVQC VVQC C C C6 M CM 6 B B B6 B M Series VQC Manifold model Plug-in
More informationABB i-bus KNX HIL/S , Hotel IP Link, Bundle
ABB i-bus KNX HIL/S 20.1.1, Hotel IP Link, Bundle Description of product HIL/S 20.1.1 Hotel IP Link, Bundle The Hotel IP Link is used to connect zones of up to 20 KNX TP devices with central systems (such
More informationUP Series Miniature Pilot Lights
Available in Various Sizes Five illumination colors: amber, green, red, white, yellow Various sizes and design. Available with a built-in current limiting resistor. Waterproof () types available for and.
More informationManual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry
Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal
More informationTransistor Remote Modules
Transistor Remote Modules Compact 8-point and 16-point Transistorized Modules Compact (8-point models: 125 x 40 x 50 mm (W x H x D); 16-point models: 150 x 40 x 50 mm (W x H x D)) Two independent supplies
More information5 Port Solenoid Valve
Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less
More informationEX510 Series Serial System Technical Specifications
No.EX##-OMI000-A EX50 Series Serial System Technical Specifications GW Unit Applicable to DeviceNet : EX50-GDN Input Unit connector inputs type ( wire) : EX50-DXB connector inputs type (NPN) : EX50-DXN
More information2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions
-Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color
More informationCircuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...
Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal
More information503 series. GENERAL Operating pressure
FEATURES rate up to 00 l/min Spool & Sleeve or rubber packed technology in the same dimension body Wide electrical connection selection : G3 or 580 Fieldbus Electronics, 25 or 37 Pin Sub-D connector, 19
More informationElectric Actuator/ Guide Rod Type
ourtesy of M/Flodyne/Hydradyne Motion ontrol Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Size How to Order LEYG M B 50 S N1 Bearing type M Sliding bearing L Ball bushing bearing
More informationCircuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories
Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks
More informationThread type to 0.8 MPa to 0.8 MPa. Note) Air operated type is model IR2120 only. Note) Air operated type is model IR3120 only.
Precision Regulator Series IR//3 5 Precision Regulator Series IR//3 Features Precise air pressure regulator for instrument applications. Three body sizes available. Pressure unaffected by supply pressure
More informationConforms to ISO Standard Size 18 mm, 26 mm Plug-in Type. 5 Port Solenoid Valve
Conforms to IO 0- tandard ize mm, mm Plug-in Type Port olenoid Valve eries V -/V - R R [Option] eries V R- eries V R- Conforms to IO 0- tandard IO tandard: Interface conforming to mm size (V -) and mm
More informationABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011
Technical data 2CDC502097D0201 ABB i-bus KNX Product description HIL/S 20.1.1 The Hotel IP Link is used to connect zones of up to 20 KNX TP devices with central systems (such as Visualizations or Hotel
More informationFIELDBUS ELECTRONICS 580 Electronics (Series : M7 to 1/2 (G or NPT) or with push-in fittings Ø4 to 10 mm)
FIELDBUS ELECTRONICS 580 Electronics (Series - : M7 to 1/2 (G or NPT) or with push-in fittings Ø4 to 10 mm) 580 Fieldbus - Electronics Made Easy! Innovative Graphic Display is used for easy commissioning,
More information2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A
2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/ISEA New M8 connector type RoHS IP65 Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously.
More informationALS SERIES VALVE MONITOR ATEX. Exd
ALS SERIES MONITOR ATEX Exd AHEM ontrols Inc Add: Main St. N. #. ampbellville, Ontario anada Tel: 00-0--.ext. Fax: 00-0-- E-mail: Kevin.armstrong@achemgroup.com www.achemgroup.com sales@achemgroup.com
More informationIB IL 24 SEG/F. Function. INTERBUS Inline Segment Terminal With Fuse. Data Sheet 5656B
INTERBUS Inline Segment Terminal With Fuse Data Sheet 5656B 02/2001 # $ # $ ) This data sheet is intended to be used in conjunction with the Configuring and Installing the INTERBUS Inline Product Range
More information10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight
VDE 2c, 3c AMP POWER RELAY RELAYS 2. 1.72 FEATURES Interchangeable with existing models Long life and high reliability High contact capacity up to A 20 Available with plug-in/solder and quick-connect terminals
More information5/2 and 5/3 Way Valves
Caracteristics to VDI 9 Pressures quoted as gauge pressure Characteristics Symbol Unit Description General Features Ceramic Spool Valve Mounting On base plate, Tube connection Base plate Port size G1/
More informationSI unit for EtherCAT. EX260 Series
PRODUCT NAME SI unit for EtherCAT MODEL / Series / Product Number EX260 Series Contents Safety Instructions 2 How to Order 7 Summary of Product elements 8 Installation and Cabling 9 Installation 9 Connecting
More informationExample. U side. Stations SY5000
45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example
More information5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted
Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted
More informationV Series Manifold Valves with Collective Wiring Size 1. V Series Size 1 Pneumatic Connectors. Moduflex Valve System V Series Manifold Valves Size 1
Ordering Guide V Series Manifold Valves with ollective Wiring Size V Series Manifold Valves Size V Series Size Pneumatic onnectors PMDYY HMDXX MMDVA Moduflex PVL Size Electro-Pneumatic Manifold Valves,
More informationSI unit for Ethernet POWERLINK
PRODUCT NAME SI unit for Ethernet POWERLINK MODEL / Series / Product Number EX260 Series Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product elements 9 Installation
More informationLUMIFA LED Light Strips Long-lasting & so bright you gotta wear shades!
LUMIFA LED Light Strips Long-lasting & so bright you gotta wear shades! LF1A Series shown As IDEC continues to move towards a green future, we are excited to announce the LUMIFA series of LED light strips,
More information4 Port Solenoid Valve Cassette Type Manifold Rubber Seal
Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are
More informationElectric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC
Electric Cylinder LZB/LZC Series It can be operated like an air cylinder. LZB Series LZC Series Model LZB LZC Max. thrust Max. speed 196 N 0 mm/s Lead screw Slide screw: ø8, ø Lead: 2, 6, Stroke 25, 40,
More informationTechnical Specifications
No.EX##-OMG0008 Technical Specifications Product name : SI Model : EX240-SIB (EX240-IE) Contents. SAFETY... P2 2. Specification 2-. Network specification (EX240-SIB)... P5 2-2. General specification...
More informationABL Series. Relay Terminal Block (Screwless Type) Features
ABL Series Relay Terminal Block (Screwless Type) Features Input (NPN, PNP common) and Output (Independent, Common) Selection with Jumper Bars Allows switching between NPN common and PNP common inputs by
More informationHow to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa
oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure
More information3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.
2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing
More informationOption. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications
Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable
More informationSingle-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC
PCB Relay R G5LE-E/-G Single-pole 0A35VDC 0.8mm Contact Gap Power Relay : Single-pole 6A250VAC Power Relay : G5LE-E Sub-miniature 'sugar cube ' relay with universal terminal footprint. UL class-f coil
More informationEX##-OMN0011-A. SI unit for EtherCAT PRODUCT NAME. EX260 Series MODEL/ Series
EX##-OMN0011-A SI unit for EtherCAT PRODUCT NAME EX260 Series MODEL/ Series Contents Safety Instructions 2 How to Order 7 Summary of Product elements 8 Installation and Cabling 9 General instructions on
More informationINLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1
INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn
More informationFeatures. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)
817 Cylindrical Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.1576~ guide... P.781~ General precautions... P.1579~ PHOTO PHOTO panasonic.net/id/pidsx/global
More informationSS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring
Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02
More informationClearwater Tech - Phone: Fax: Web: -
Accessories Bus cables PROFIBUS-PA cables Straight version PROFIBUS-PA Ex i cables Straight version TM-I marker sleeve TM-I marker sleeve Designation Type Order No. Industrial zone PROFIBUS-PA cable One
More informationpanasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!
655 Door with Key SERIES Related Information General terms and conditions... F-7 General precautions... P.50 PHOTO PHOTO Conforming to Machine & EMC Directives Recognition Certified MEASURE ITY panasonic.net/id/pidsx/global
More informationGeneral Purpose Relay
General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)
More informationHS1C Interlock Switches with Solenoid
HSC es with The guard door remains locked until the machine stops completely. With the actuator mounted on the guard door and the interlock switch on the machine, the door is mechanically locked when closed.
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (00) 6-0 www.cmafh.com Safety Interlock Switches DSL-N Super Small Class 6-Contact uard Lock Safety-Door Switch
More informationSTEEMCO-MAS Flowmeter for Steam
STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationA K 3 E D G
005 Series. How to Order - G3 or Multipol Assembly Kit A K 3 E D 0 0 0 0 3 G A36 Electronic / Electrical Systems Type & Location 3 = T = Terminal Strip - 3 J = 5 pin SUB-D connector M = 37 pin SUB-D connector
More informationHow to Order Manifold. Option Symbol
Series Plug Lead nit For details about certified products conforming to international standards, visit us at www.smcworld.com. Series/Manifold 12 Stations 01 1 station Kit/Electrical entry/cable length
More informationInductive conductivity meter
Inductive conductivity meter Type 8228 can be combined with... Configurable outputs: up to 2 transistor and up to 2 analog 4... 20 ma outputs Removable backlighted display Simulation of process values
More information5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal
Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage
More informationLow voltage AC drives
General machinery drives Main features and dimensions Unique features Fast and extensive I/O PID control Application macros Many installation possibilities 200 to 480 V, 1-phase or 3-phase More value for
More informationStandard Interlock Safety Switches
Subminiature Interlock Switches Key features: Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening
More informationPHOTOELECTRIC S300 PA MAXI SENSORS APPLICATIONS.
PHOTOELECTRIC MAXI SENSORS S300 PA The S300 PA series of advanced MAXI photoelectric sensors represents the most suitable solution for standard applications thanks to it s excellent cost/performance ratio.
More informationINSERTION flow sensor for continuous flow measurement
INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More information5 Port Solenoid Valve
Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less
More informationRU Series Universal Relays
Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal
More informationPHOENIX CONTACT - 01/2008
Exi Solenoid Driver, With Intrinsically Safe Output, LoopPowered, TwoChannel INTERFACE Data Sheet 0289_00_en PHOENIX CONTACT 0/2008 Description The PIEXME2SD/24/65C is a twochannel solenoid driver. It
More informationCAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000
CAT.E- Port Solenoid Valve/Body Ported Cassette Type Manifold Series SZ000 The plug-in cassette system makes valve replacement easy. A plug-in manifold has been realized having a manifold height of.mm
More informationHS1C-P Interlock Plug Unit with Door Lock
HSC-P Unit with Lock Interlock plugs with door lock mechanism for high level safety management. Installing the actuator on the guard door and the interlock switch on the machine, the guard door can be
More information9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!
Digital Pressure Switch Series ZSE1(F)/ISE1 Low profile 26.1mm 9.8 mm 13.5 mm 53.4 mm Reduced in depth! (Actual size) RoHScompliant Vertical mounting space reduced to approx.! 1 2 Position Detection Switch
More informationApplicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500
5 Port Solenoid Valve Series C000 Metal Seal Rubber Seal Compact and large flow Type (Series) Manifold pitch (mm) C000 5 6. 0.7.7 7. 0..0 to ø Note) Flow characteristics: position single, / 5/ (/ R/R)
More information82 Series MAConnect with Sub-D
82 Series MAConnect with Sub-D Maximum of 20 solenoids can be powered by a single multi-pin connector. Up to 40 solenoids can be powered by means of a second multi-pin connector station. Left or right
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible
More informationSeries ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE
High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1
More informationElectric Drives. Linear Motion and Assembly Technologies Pneumatics Service. Valves, Series VP15. Technical data
Electric Drives and Controls Hydralics Linear Motion and Assembly Technologies Pneumatics Service Valves, Series VP5 Technical data Completely mounted valve terminal system, BUSdirect (Profibus DP) Technical
More information92 Series MAConnect with Sub D
9 Series MAConnect with Sub D MAXIMUM OF 0 SOLENOIDS CAN BE POWERED BY A SINGLE MULTI-PIN CONNECTOR. UP TO 40 SOLENOIDS CAN BE POWERED BY MEANS OF A SECOND MULTI-PIN CONNECTOR STATION. LEFT OR RIGHT END
More informationIndustrial Relay KML(1C, 2C)
Industrial Relay KML(1C, 2C) Features 1C: 15A, 2C: 10A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 & 2 poles configurations
More informationDIGITAX ST UNIMOTOR 2000RPM COMBINATIONS
DIGITAX ST UNIMOTOR FM @ 2000RPM COMBINATIONS Table data based on 2000 rpm motors 3x Torque Part Part DST1201 0.72 1.0 2.16 2.9 0.12 055E2A300 DST1201 1.2 0.9 3.6 2.6 0.7 075E2A200 DST1201 1.4 1.7 4.2
More informationValve Manifolds. Series Fielbus Electronics - 51
Valve Manifolds 07GB-07/R0 Series 0 Fielbus Electronics - 0 Series General Information 0 Valve Series belong to the Numatics Valve Generation 000. With up to outputs and 96 inputs., depending on the protocols
More information6mm and 14mm Slim Interface Relay
6mm and mm Slim Interface Relay RV8 Series 6mm Width Electromechanical Screw Terminal Solid State Spring Clamp Terminal PRODUCT DESCRIPTION IDEC 6mm and mm interface relays provide a compact solution for
More information1 Form A 5A small size power relay for interface
1 Form A 5A small size power relay for interface PQ RELAYS RoHS compliant Protective construction: Sealed type FEATURES 1. Compact and slim 20 mm (L) mm (W) 16 mm (H).787 inch (L).394 inch (W).630 inch
More informationRelated vacuum products
Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter
More information