mainly used for power distribution

Size: px
Start display at page:

Download "mainly used for power distribution"

Transcription

1 Product family strip type fuse-switch-disconnector strip type fuseswitch-disconnectors are mainly used for power distribution in low voltage assemblies in accordance with IEC/EN (VDE 0660 Teil 500). The strips are type tested in accordance with IEC/EN Size 00-4a 1-pole and 3- pole switchable versions are available. Top or bottom cable connection as required Optimum fuse pick-up contact Direct-connection terminal Double strip up to 2000A 910A compact switch strips for 630kVA transformer supply Multipurpose cover Modular design High breaking capacity Low power loss Use of standard earthing accessories 7-0

2 Product group Product type 1-pole switchable Sizes 00-4a /160A A Page (SASIL) 3-pole switchable Current transformer mounting 3-pole switchable LVHRC busbar disconnect strip, 1-pole and 3-pole switchable Sizes 00-3 /160A A Sizes 00-3 / 160A - 630A Sizes 3 / 630A A fuses (SASIL) BS (SASIT) DIN and BS s Accessories Terminals, adapters and accessories meter fuse-link (SALIT) Drawings Technical data Terminals LV HRC stripfuseways strip-type fusebases C O S M O - 60mm Busbar System Current Consumer supply technology Distribution and instrument cabinets Powerlizer electronics 7-1 Appendix

3 Mounting of fuse switch strips SL00-3 x 3 / Example with device and accessories, busbar distance mm, 3-pole switchable Strip base U-SL00-3 x 3/ 2 Swing-in device D-SL00-3 x 3/ 3 Actuating lever SH-SL00-3 x 3/ 4 Terminal compartment cover HA-SL00-3 x 3/ 5 Terminal compartment extension HAV-SL00-3 x 3/ 6 Flat terminal F-M8x16 7 Clamp-type terminal S00-Z 8 V-terminal clamp P0070-Z 9 Elevator clamp F70 10 V box terminal KU00 11 V box terminal KM00 12 Busbar terminals SK-SL00 13 Position indicator EV-SL00/ Current WKD50 15 Holder for spacer roller HDR20 16 Cover holder AH-SL 17 Cover holder with quick-release lock AH-SL/S 18 Cover support AHCT-SL 7-2

4 Mounting of fuse switch strips S - 3 x 3, S - 3 x 3, S - 3 x 3 Example with device and accessories, busbar distance mm, 3-pole switchable (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) 16 Terminals LV HRC stripfuseways 8 strip-type 17 (18) 9 fusebases 1 Strip base U-S U-S U-S 2 Strip top O-S/3 x 3 O-S/3 x 3 O-S/3 x 3 3 Screw terminal Connectiontype 3a Gr.1 M10 x 25 Gr.2, 3 M12 x 30 4 Stud terminal Connectiontype 4a Gr.1, 2, 3 M12 x 35 5 Stud terminal Connectiontype 4a-60 Gr.1, 2, 3 M12 x 60 6 Multiple V box terminal Connectiontype 9 Terminal type KM2G-F mm 2 7 Multiple box terminal Connectiontype 9 Terminal type KM2G mm 2-300mm 2 8 Retrofittable direct-connection terminal K2G/A mm 2 9 Kit for connection of 2 cable lugs per phase FK2 x Terminal compartment cover HA-S23/10 11 Cover holder AH-SL 12 Cover holder with quick-release lock AH-SL/S 13 Fastening clips with T profile AHCT-SL Designation plate, top BZO-S23 15 Position indicator EV-SL/3 x 3/10 16 Hang-up device MW-S23 17 Terminal retrofit kit KM2x240-S23/3A 18 Terminal retrofit kit KM2x240-S23/9 C O S M O - 60mm Busbar System Current Consumer supply technology Distribution and instrument cabinets Powerlizer electronics 7-3 Appendix

5 Current distribution components strip-type fuse switch-disconnectors 1-pole switchable Sizes 00-4a / 160A -2000A Product definition 3-pole strip-type fuse switch-disconnectors for mounting on busbars. They combine three lengthwise-arranged 1-pole fuse switch-disconnectors in one unit. One contact of each phase (incoming contact) is connected to one phase of a 3-pole busbar. The other contacts (outgoing contacts) are equipped with conductor terminals. Applications The universal fuse switch-disconnectors are used in low voltage distribution cabinets, network and transformer stations and cable distribution cabinets of power supply and industrial companies, where they comply with all power distribution requirements. The following current ratings are available: 160A, 250A, 400A, 630A, size 3/910A, size 3/0A with disconnecting blades, size 3/1250A as double strip, size 3/1600A as double strip with disconnecting blades, size 3/2000A as double strip with disconnecting blades. Still, the series in size 4a is available up to 1250A. Operational principle The fuse switch-disconnectors are used for accomodating LV HRC fuse-links and thus for breaking of circuits. They are 1-pole switchable and can be switched under load. The universal swing-in devices allow the use of current meters in conjunction with meter fuses and piggyback fuses for worksite tapping. The cable outlet (top or bottom) can be freely selected on site. Product construction The one-piece strip body, which accomodates current-carrying parts, consists of high-strength glass-fibre-reinforced polyester. The silver-plated contact for accomodating the fuse-links equipped with tin-plated discharge rails ensures low power loss, optimum thermal characteristics and high switching capacity. The downward connecting bars are designed for flat termination as standard, but it is also possible to fit direct-connection terminals. The live parts of size 1-3 strips, such as contacts and discharge rails, remain back-of-hand proof after removal of the upper part due to the contact covers with integrated arcing chamber which remain at the base. Twist locks allow straightforward removal and fitting of the upper parts of the strips with the swing-in devices. 7-4

6 Size Busbar Type of connection, sizes 00-3 (F: flat termination B: box terminal S: screw terminal ST: stud MB: multiple box terminal) Cable outlet (C: connection V: variable R: rear T: top B: bottom L: lateral) Swing-in device (S: standard RH: retractable handle) Std.P Type Article No. 00 mm F T/B S X/F L mm F T/B RH X/F/GV L mm B T/B S X/KU00 L mm B T/B RH X/KU00/GV L mm S T/B S 1 1-3X/3A mm S T/B RH 1 1-3X/3A/GV mm ST, M12x35 T/B S 1 1-3X/4A mm ST, M12x35 T/B RH 1 1-3X/4A/GV mm ST, M12x60 T/B S 1 1-3X/4A mm ST, M12x60 T/B RH 1 1-3X/4A-60/GV mm MB, fixed T/B S 1 1-3X/9/KM2G mm MB, fixed T/B RH 1 1-3X/9/KM2G/GV mm MB, loose T/B S 1 1-3X/9/KM2G-F mm MB, loose T/B RH 1 1-3X/9/KM2G-F/GV mm S T/B S 1 2-3X/3A mm S T/B RH 1 2-3X/3A/GV mm ST, M12x35 T/B S 1 2-3X/4A mm ST, M12x35 T/B RH 1 2-3X/4A/GV mm ST, M12x60 T/B S 1 2-3X/4A mm ST, M12x60 T/B RH 1 2-3X/4A-60/GV mm MB, fixed T/B S 1 2-3X/9/KM2G mm MB, fixed T/B RH 1 2-3X/9/KM2G/GV mm MB, loose T/B S 1 2-3X/9/KM2G-F mm MB, loose T/B RH 1 2-3X/9/KM2G-F/GV /0A mm S CRT S 1 3-3X/0/ARO /0A mm S T/B S 1 3-3X/0/HA mm S T/B S 1 3-3X/3A mm S T/B RH 1 3-3X/3A/GV mm ST, M12x35 T/B S 1 3-3X/4A mm ST, M12x35 T/B RH 1 3-3X/4A/GV mm ST, M12x60 T/B S 1 3-3X/4A mm ST, M12x60 T/B RH 1 3-3X/4A-60/GV mm MB, fixed T/B S 1 3-3X/9/KM2G mm MB, fixed T/B RH 1 3-3X/9/KM2G/GV mm MB, loose T/B S 1 3-3X/9/KM2G-F mm MB, loose T/B RH 1 3-3X/9/KM2G-F/GV /910A mm S T/B S 1 3-3X/910/AO/AU /910A mm S T/B S 1 3-3X/910/AO/AU /910A mm S T/B S 1 3-3X/910/AO/AU /910A mm S CRT S 1 3-3X/910/ARO /910A mm S CRT, 110 S 1 3-3X/910/ARO/ /910A mm S CRBL S 1 3-3X/910/ARUS /910A mm S T/B S 1 3-3X/910/HA /910A mm S CRT, long S 1 3-3x/910/AORL /910A mm S CRT, short S 1 3-3x/910/AORK /910A mm S T S 1 3-3X/910/AO /1250A mm S T/B S 1 3-3X2/1250/HA /1600A mm S T/B S 1 3-3X2/1600/HA 9202 SL... (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) Terminals LV HRC stripfuseways strip-type fusebases C O S M O - 60mm Busbar System Current Consumer supply technology Distribution and instrument cabinets Powerlizer electronics 7-5 Appendix

7 Size Busbar Type of connection, sizes 00-3 (F: flat termination B: box terminal S: screw terminal ST: stud MB: multiple box terminal) Cable outlet (C: connection V: variable R: rear T: top B: bottom L: lateral) Swing-in device (S: standard RH: retractable handle) Std.P Type Article No. 3/2000A mm S T/B S 1 3-3x2/2000/HA A mm S B S 1 TL4A-3AS/3X/4 L4242 4A / width 7 mm S B S 1 TL4A-3AS/3X/2X3A/Q/7K L A / width 7 mm S T S 1 TL4A-3AS/3X/2X3A/Q/7K/AO L A mm S T S 1 TL4A-3AS/3X/4/AO L SL

8 (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) Terminals LV HRC stripfuseways strip-type fusebases C O S M O - 60mm Busbar System Current Consumer supply technology Distribution and instrument cabinets Powerlizer electronics 7-7 Appendix

9 Current distribution components strip-type fuse switch-disconnectors 3-pole switchable Sizes 00-3 / 160A-2000A Product definition 3-pole strip-type fuse switch-disconnectors for mounting on busbars. They combine three lengthwise-arranged 1-pole fuse switch-disconnectors in one unit. One contact of each phase (incoming contact) is connected to one phase of a 3-pole busbar. The other contacts (outgoing contacts) are equipped with conductor terminals. Applications The universal fuse switch-disconnectors are used in low voltage distribution cabinets, network and transformer stations and cable distribution cabinets of power supply and industrial companies, where they comply with all power distribution requirements. The following current ratings are available: 160A, 250A, 400A, 630A, size 3/910A, size 3/0A with disconnecting blades, size 3/1250A as double strip, size 3/1600A as double strip with disconnecting blades, size 3/2000A as double strip with disconnecting blades. Operational principle The fuse switch-disconnectors are used for accomodating LV HRC fuse-links and thus for breaking of circuits. They are 3-pole switchable and can be switched under load. The universal swing-in devices allow the use of current meters in conjunction with meter fuses and piggyback fuses for worksite tapping. The cable outlet (top or bottom) can be freely selected on site. Product construction The one-piece strip body, which accomodates current-carrying parts, consists of high-strength glass-fibre-reinforced plastic. The silver-plated contact for accomodating the LV HRC fuse-links equipped with tin-plated discharge rails ensures low power loss, optimum thermal characteristics and high switching capacity. The downward connecting bars are designed for flat termination as standard, but it is also possible to fit direct-connection terminals. The live parts of size 1-3 strips, such as contacts and discharge rails, remain back-of-hand proof after removal of the upper part due to the contact covers with integrated arcing chamber which remain at the base. Twist locks allow straightforward removal and fitting of the upper parts of the strips with the swing-in devices. Electronic fuse monitor PLFuse (ES00) The PLFuse electronic fuse monitor is used for continuous fuse monitoring in 3-phase low voltage networks. The potential-free relay contacts of the fuse monitor allow the make/break contacts to be designed for individual or centralized fault indication as required. No fuse failure is indicated in the event of network disconnection or phase failure. 7-8

10 Size Busbar Type of connection, sizes 00-3 (F: flat termination F70: elevator terminal B: box terminal S: screw terminal ST: stud MB: multiple box terminal) Cable outlet (C: connection V: variable R: rear T: top B: bottom L: lateral) Electronic fuse monitor (400V-690VAC) Std.P Type Article No. 00 mm F B With X3//F/ES00 L mm F T/B Without X3//F L mm F70 T/B Without X3//F70 L mm B T/B Without X3//KU00 L mm B T/B Without X3//KM00 L mm F T/B Without X3/F L mm B T/B Without X3/KU L mm S T/B Without 1 1-3X3/3A mm S B With 1 1-3X3/3A/ES mm ST, M12x35 T/B Without 1 1-3X3/4A mm ST, M12x60 T/B Without 1 1-3X3/4A mm MB, loose T/B Without 1 1-3X3/9/KM2G-F mm MB, fixed T/B Without 1 1-3X3/9/KM2G mm S T/B Without 1 2-3X3/3A mm S B With 1 2-3X3/3A/ES mm ST, M12x35 T/B Without 1 2-3X3/4A mm ST, M12x60 T/B Without 1 2-3X3/4A mm MB, fixed T/B Without 1 2-3X3/9/KM2G mm MB, loose T/B Without 1 2-3X3/9/KM2G-F /0A mm S T/B Without 1 3-3X3/0/HA mm S T/B Without 1 3-3X3/3A mm S B With 1 3-3X3/3A/ES mm ST, M12x35 T/B Without 1 3-3X3/4A mm ST, M12x60 T/B Without 1 3-3X3/4A mm MB, fixed T/B Without 1 3-3X3/9/KM2G mm MB, loose T/B Without 1 3-3X3/9/KM2G-F /910A mm S T/B Without 1 3-3X3/910/AO/AU /910A mm S T/B Without 1 3-3X3/910/AO/AU /910A mm S T Without 1 3-3X3/910/AORK /910A mm S T Without 1 3-3X3/910/AORL /910A mm S T Without 1 3-3X/910/AO /910A mm S T/B Without 1 3-3X3/910/AO/AU /910A mm S CRT Without 1 3-3X3/910/ARO /910A mm S CRBL Without 1 3-3X3/910/ARUS /910A mm S T/B Without 1 3-3X3/910/HA /1250A mm S T/B Without 1 3-3X6/1250/HA /1600A mm S T/B Without 1 3-3X6/1600/HA /2000A mm S T/B Without 1 3-3X6/2000/HA SL... (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) Terminals LV HRC stripfuseways strip-type fusebases C O S M O - 60mm Busbar System Current Consumer supply technology Distribution and instrument cabinets Powerlizer electronics 7-9 Appendix

11 Current distribution components strip-type fuse switch-disconnectors Transformer installation, with single- and three-phase switching Sizes 00-3 / 160A-630A Product definition The universal load-disconnect strip fuseways comply with all requirements for power distribution in electricity utility companies and in general industry when used in low-voltage distributors. Current can be integrated into the carriers for measuring purposes. Applications The universal fuse switch-disconnectors are used in low voltage distribution cabinets of power supply and industrial companies, where they comply with all power distribution requirements. Current can be integrated into the carriers for measuring purposes. Operational principle The fuse switch-disconnectors are used for accomodating LV HRC fuse-links and thus for breaking of circuits. They are 1-pole and 3-pole switchable and can be switched under load. The upper parts of the strips, which comply with degree of protection IP3x when installed, are equipped as standard with test apertures to permit voltage measurement with voltage testers in accordance with DIN/VDE 0680 Part 5. The cable outlet (top or bottom) can be freely selected on site. Current can be integrated into the carriers for measuring purposes. If strips with and without current are installed together, the installation dimensions remain unchanged. Single-phase and three-phase measurements are possible. The wiring for the secondary side of the current transformer is laid on the rear of the carrier. Product construction The one-piece strip body, which carries the live components, is made of fibreglass-reinforced plastic which is resistant to high temperatures. The silver-plated contact for accomodating the LV HRC fuse-links equipped with tin-plated discharge rails ensures low power loss, optimum thermal characteristics and high switching capacity. The downward connecting bars are designed for flat termination as standard, but it is also possible to fit direct-connection terminals (suitable for Al- and Cu-cable). All live components, such as contacts, infeed brackets, arrestor rails and terminal space, are protected against accidental contact in accordance with BGV A2. There are two different types: The version W is suitable for direct installation of a current transformer, while the version WN is prepared for later installation of s current transformer. 7-10

12 Size Busbar distance Current transformer mounting (MP: Current transformer mounting possible R: Current transformer retrofittable) Type of connection, size 00 (F: flat termination F70: elevator terminal B: box terminal) Type of connection, sizes 1-3 (S: screw terminal) Std.P Type Article No. 00 mm MP F X3//W/F L mm MP F X3//W/F70 L mm MP B X3//W/KU00 L mm MP B X3//W/KM00 L mm R F X3//WN/F L mm R F X3//WN/F70 L mm R B X3//WN/KU00 L mm R B X3//WN/KM00 L mm MP S 1 1-3x3/W/3A mm R S 1 1-3x3/WN/3A mm MP S 1 2-3x3/W/3A mm R S 1 2-3x3/WN/3A mm MP S 1 3-3x3/W/3A mm R S 1 3-3x3/WN/3A mm MP S 1 1-3x/W/3A mm R S 1 1-3x/WN/3A mm MP S 1 2-3x/W/3A mm R S 1 2-3x/WN/3A mm MP S 1 3-3x/W/3A mm R S 1 3-3x/WN/3A mm MP S 1 3-3x3/0//W/HA mm R S 1 3-3x3/0//WN/HA SL... (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) Terminals LV HRC stripfuseways strip-type Current transformer for SL00 see chapter current transformer page Current transformer for S23 see chapter current transformer page fusebases C O S M O - 60mm Busbar System Current Consumer supply technology Distribution and instrument cabinets Powerlizer electronics 7-11 Appendix

13 Current distribution components strip-type fuse switch-disconnectors busbar disconnect strip, 1- and 3-pole switchable Size 3 / 630A-2000A Product definition busbar disconnect strips are 3-pole strip-type fuse switch-disconnectors for mounting on busbars. They combine three lengthwise-arranged 1-pole fuse switch-disconnectors in one unit. One contact of each phase (incoming contact) is connected to one phase of a 3-pole busbar. The lateral outgoing connections allow coupling of a second distribution. Applications The busbar disconnect strips are used in low voltage distribution cabinets, network and transformer stations and cable distribution cabinets of power supply and industrial companies, where they comply with all power distribution requirements. The following current ratings are available: 630A, size 3/910A, size 3/0A with disconnecting blades and size 3/2000A as double strip. Sizes 3 for 0A and 2000A are delivered with disconnecting blades. Operational principle The busbar disconnect strips are used for accomodating fuse-links and thus for breaking of circuits. They are 1- and 3-pole switchable and can be switched under load. The universal swing-in devices allow the use of current meters in conjunction with meter fuses and piggyback fuses for worksite tapping. The terminal lugs led through at the right or left side, which allow coupling of a second busbar, are arranged in such a way that the neighbouring strip can be fitted in a mm grid. Product construction The one-piece strip body, which accomodates current-carrying parts, consists of high-strength glass-fibre-reinforced polyester. The silver-plated contact for accomodating the fuse-links equipped with tin-plated discharge rails ensures low power loss, optimum thermal characteristics and high switching capacity. The lateral (right or left) outgoing connections allow coupling of a second busbar. The live parts such as contacts and terminal lugs remain back-of-hand proof after removal of the upper part due to the contact covers with integrated arcing chamber which remain at the base. Twist locks allow straightforward removal and fitting of the upper parts of the strips with the swing-in devices. 7-12

14 Size Rated operational current (A) Switched poles Disconnecting blade Busbar disconnection Std.P Type Article No. SLT3-3S A 1-pole Left side 1 L/3X /0A 0A 1-pole TM3/1250 Left side 1 L/3X/ /910A 910A 1-pole Left side 1 L/3X/ A 1-pole Right side 1 R/3X /0A 0A 1-pole TM3/1250 Right side 1 R/3X/ /910A 910A 1-pole Right side 1 R/3X/ /2000A 2000A 1-pole TM3/1250 Right side 1 R/3X2/ A 3-pole Left side 1 L/3X /0A 0A 3-pole TM3/1250 Left side 1 L/3X3/ /910A 910A 3-pole Left side 1 L/3X3/ A 3-pole Right side 1 R/3X /0A 0A 3-pole TM3/1250 Right side 1 R/3X3/ /910A 910A 3-pole Right side 1 R/3X3/ /2000A 2000A 3-pole TM3/1250 Right side 1 R/3X6/ (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) Terminals LV HRC stripfuseways strip-type fusebases C O S M O - 60mm Busbar System Current Consumer supply technology Distribution and instrument cabinets Powerlizer electronics 7-13 Appendix

15 Current distribution components strip-type fuse switch-disconnectors Accessories Accessories Product definition TERMINALS Terminals are connectors for direct connection between connecting bars and lines. V-TERMINAL CLAMP The P0070-Z V-terminal clamps are suitable for fitting to size 00 strips for the connection of circular and sector-shaped Al and Cu conductors. CLAMP-TYPE TERMINAL The S00-Z terminals are suitable for fitting to size 00 strips for the connection of circular Cu conductors and Cu ribbon conductors. KIT FOR 2 CABLE LUGS The FK-2x240 kit is used for the connection of 2 cable lugs of max. 2 x 300mm² perphasetosize1to3 strips with screw terminal. It is suitable for cable lugs up to a width of 43mm. KIT FOR 2 CABLES, TERMI- NAL RETROFITTING KIT The clamping kit is used for two cables at one phase. BUSBAR TERMINALS FOR SIZE 00 Busbar terminals are used for drill-free direct contacting of the strip-fuseways on the busbars. BUSBAR TERMINALS FOR SIZE 1-3 With the aid of the busbar clamps, strips of the sizes 1 to 3 can be mounted directly on busbars without drilling holes. The SK clamps are available for busbars with thicknesses of 5mm to 10mm. BUSBAR ADAPTERS / ADAPTER CLIPS The adapters are required for combining different strip sizes, e.g. size 00 with sizes 1to3. TERMINAL COMPARTMENT / TERMINAL COVER The terminal compartment and terminal covers provide probe-safe frontal protective covering of the terminal compartment. BLANKING PLATE The blanking plate is used for frontal covering of exposed strip locations. It is placed on the switchboard at the bottom and is fixed at the top using an espagnolette. BUSBAR COVER, CLIP-TYPE The clip-type protective covers of mm width are suitable for bar thicknesses of 5mm (6mm),10mm and 15mm and bar widths of 30mm to mm. Due to their elevated position, they can also cover studs up to a length of 35mm. BUSBAR COVER, SCREW-TYPE The screw-type covers of mm width are fixed at busbars with M12 thread or stud. The covers of 50mm width are fixed on busbars or adapters with M8 thread. RESERVE PANEL COVER The reserve panel cover is used for frontal covering of exposed strip locations and is fixed at the strip sides using AH-SL and AH-SL/S cover holders. COVER HOLDER / LATERAL COVER SUPPORT The cover holders and lateral cover support are used for fixing and supporting lateral covers. DESIGNATION PLATE MOUNT The designation plate mount is plugged on the strips at the end face. It allows fitting of an additional designation plate. When fitted in switchboards, it can also be used as support for a cover. POSITION INDICATOR The 3-pole switchable strips of the sizes 00-3 and size 4A strips allow fitting of auxiliary switches with freely selectable make or break (changeover) function for indication of the connected or disconnected position. CURRENT TRANSFORMER MOUNTING KIT The current transformer mounting kit consists of the current transformer wiring aid with cable harness and a 9-pin connector to be mounted on the back of the strip. It is available for SL-strips in the sizes 1-3 and also in the size 00 for the mm and mm series. HOLDER WITH SPACER ROLLER On strips for installation of current (version W ), the holder with spacer roller must be fitted on the unmeasured phases if only single-phase measurement is used. The holders with spacer rollers are already fitted on the strips for later installation of current (version WN ). ASSEMBLY AID The assembly aid allows size 1 to 3 circuit strips to be hanged at the busbars while the is energized. BUSBAR SUPPORT The 3-pole busbar support is used for the fixing of flat bars at mm and mm distances. Lateral cover for busbar support The angled cover is screwed onto the busbar support and covers the ends of the busbars. PIGGYBACK FUSE The piggyback fuse enables fuse-protected temporary connections (worksite electrical supply) to size 1 to 3 strip-fuseways. PEN TERMINAL FOR BUILDING SITE CONNEC- TION When used with the piggyback fuse, the PEN clamp can be used to connect the neutral conductor directly to the PEN busbar. RAILING KITS The kit for 0A is used to expand the wiring space for 2 or 3 cable lugs per phase. The kit for 1250A allows 2 strips to be connected at the terminal and 3 or 4 cables per phase to be connected. CONNECTOR KITS The connector kits are used for parallel switching of 2 strips. 7-

16 Direct-connection terminal Std.P Type Article No. Size 4a, 3-wire connection, mm², Al/Cu 1 K3G/3/AF40-50 K Size 4a, 4-wire connection, mm², Al/Cu 1 K3G/4/AF40-50 K Size 4a, 2-wire connection, mm², Al/Cu 1 KV2HG-F/2/300/AF40-50 K Direct-connection terminal Std.P Type Article No. Sizes 1-3/70-240mm² Al/Cu 3 K2G/A K (SASIL) V-terminal clamp Std.P Type Article No. Size 00/10-70 mm² Al/Cu 3 P0070-Z K51038 fuses (SASIL) BS (SASIT) DIN and BS s Clamp-type terminal Std.P Type Article No. Size 00/1,5-70 mm² Cu (also for GU00) 3 S00-Z K (SALIT) Terminals Kit for 2 cable lugs Std.P Type Article No. For sizes FK2x240-S3 L LV HRC stripfuseways Terminal upgrade kit for two cables per phase Std.P Type Article No. For sizes 2-3 with connection type 3A 1 KM2x240-S3/3A L For sizes 2-3 with connection type 9 1 KM2x240-S3/9 L strip-type fusebases Busbar terminal for size 00 Std.P Type Article No. Bar thickness 5-10mm 3 SK-L/SL00 L Bar thickness 10-15mm 3 SK-L/SL00/15 L Busbar terminal for size 1-3 Std.P Type Article No. Bar thickness 5-10mm 3 SK-L/S23/10 L C O S M O - 60mm Busbar System Current Adapter clip for size 00 Std.P Type Article No. For 1 strip, /mm 1 AB-SL00/1 L For 1 strip, /mm 1 AB-SL00//1/52 L For 1 strip, 60/mm 1 AB60-SL00//1 L Consumer supply technology Distribution and instrument cabinets Powerlizer electronics 7-15 Appendix

17 Adapter strip for size 00 Std.P Type Article No. For 2 strips, /mm, height 42mm 1 AL-SL00/42 L For 2 strips, /mm 1 AL-SL00//52 L Adapterstrip for size 00 with busbar terminal Std.P Type Article No. For 2 strips, /mm 1 AL/SK-SL00//52 L For 2 strips, /mm 1 AL/SK-SL00/42 L Shrouding cover Std.P Type Article No. For KM2G multiple box terminals 3 HRV L Terminal compartment cover Std.P Type Article No. For SL00 1 HA-SL00 L For S23 1 HA-S23/10 L For S-3x2(6) 1 HA-SX2/10 L For S/910(0) 1 HA220-S23/10 L For S/910(0), extended 1 HA275-S23/10 L For SL00-3x3/ 1 HAV-SL00/ L Compensating adapters Std.P Type Article No. For SL00-3x3/ 1 BO/BU-SL00/ L Blanking plate Std.P Type Article No. For SL00-3x3/ / width 50mm 1 B-SL00/ L For SL00, width 50mm, Cover view 633mm 1 B-SL00/633 L For SL00, width 50mm, Cover view 650mm 1 B-SL00/650 L For S23, width mm, Cover view 633mm 1 B-S23/633 L For S23, width mm, Cover view 650mm 10 B-S23/650 L Cover support Std.P Type Article No. For SL00 with cover view 650mm 20 BA650-SL00/ L Busbar cover, clip-type Std.P Type Article No. mm busbar / width mm 3 H-RF S

18 Busbar covers, screw-type Std.P Type Article No. mm busbar / width 50mm, M8 3 H-SL00 L mm busbar / width 50mm, M8 3 H-SL00/ L mm busbar / width mm, M12 2 H-S23/662 L mm busbar / width mm, M12/St 3 H-S23/ST L Reserve panel cover Std.P Type Article No. For SL00 / width 50mm 1 LA-SL00 L For S23 / width mm 1 LA-S23 L Cover holder Std.P Type Article No. With fixing screw 4 AH-SL L With quick-release lock 4 AH-SL/S L (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s Lateral cover support Std.P Type Article No. 3 clips with T profile (length 650mm) 2 AHCT-SL00-3 L (SALIT) Terminals Mechanical fuse monitor 3-pole Std.P Type Article No. Size 4a 1 K/EV-LTL/SLTL4A T LV HRC stripfuseways Designation plate, top Std.P Type Article No. For SL00 5 BZO-SL00 L For S23 5 BZO-S23/10 L strip-type fusebases Position indicator Std.P Type Article No. For SL00-3x3/ 1 EV-SL00/ L For SL00, 3-pole switchable 1 EV-SL00/3X3 L For S23, 3-pole switchable 1 EV-S23/3X3/10 L C O S M O - 60mm Busbar System Current transformer mounting kit for size 1-3 Std.P Type Article No. For 1 current transformer type WSD30 in phase 1 1OW/-L/S23 L For 3 current type WSD30 1 3OW-L/S23 L Current Transformer holder for strip size 00-3 Std.P Type Article No. 1/250A-3/630A with spacer sleeve 45mm, for WSD25 3 WH123+DH45/DI12,5 L /250A-3/630A with spacer sleeve 55mm, for WSD30 3 WH123+DH55/DI12,5 L /160A with spacer sleeve 45mm, for WSD25 3 WH00+DH45/DI8,5 L /160A with spacer sleeve 55mm, for WSD30 3 WH00+DH55/DI8,5 L Consumer supply technology Distribution and instrument cabinets Powerlizer electronics 7-17 Appendix

19 Transformer holder for strip size 3 Std.P Type Article No. 3/0A with spacer sleeve 60mm, for WSD40 3 WH3+DH60/Dl12,5 L Current-transformer upgrade kit for three, complete with cable harness and plug-in terminal Std.P Type Article No. with spacer sleeve 45mm, without transformer, for WSD25 1 WH123+DH45/DI12,5/KB L with spacer sleeve, without transformer, for WSD30 1 WH123+DH55/DI12,5/KB L SL00/ with spacer sleeve 45mm, for WSD25 1 WH00+DH45/DI8,5/KB/ L SL00/ with spacer sleeve 55mm, for WSD30 1 WH00+DH55/DI8,5/KB/ L SL00/ with spacer sleeve 45mm, for WSD25 1 WH00+DH45/DI8,5/KB/ L SL00/ with spacer sleeve 55mm, for WSD30 1 WH00+DH55/DI8,5/KB/ L Holder with spacer roller Std.P Type Article No. Hight 20mm, for SL00/ 1 HDR20-SL00/ L Hight 26mm, for sizes HDR26-S23 L Hight 26mm, for size 3/0 1 HDR26-S23 L Fixing bracket Std.P Type Article No. For sizes MW-S23 L Busbar support Std.P Type Article No. For mm and mm busbar distance, M10, 30Nm 10 SH/ S Lateral cover for busbar support Std.P Type Article No. For mm busbar distance 2 HW-SH/ S For mm busbar distance 2 HW-SH/ S Piggyback fuse Std.P Type Article No. Contact blade, long 3 HP-SE/L L PEN terminal for building site connection Std.P Type Article No. For 5-10mm busbar thickness 1 SK-S0070 K

20 Railing kit Std.P Type Article No. For S/3, connection 2x300mm², 3x120mm² 1 VS-S/0 L For S/3, connection 1x400mm² 1 VS-S/400mm² L Railing kit for double strip Std.P Type Article No. For S-3x2(6)/1250A, connection 3x300mm², 4xmm² 1 VS-S/1250 L For S-3x2(6)/1250A, connection 4x240mm² 1 VS-S/4x240mm² L (SASIL) Connector kit Std.P Type Article No. For S-3x2(6) 1 VBS-SX2(6) L fuses (SASIL) BS (SASIT) DIN and BS s Fixing screws Std.P Type Article No. For SL00 3 F-M8x40 L For S23 3 F-M12x50 L (SALIT) Terminals Terminal strip Std.P Type Article No. For SL00-fuse strip with current transformer 1 BS-KL-SL00 L For S23-fuse strip with current transformer 1 BS-KL-S23 L LV HRC stripfuseways strip-type fusebases C O S M O - 60mm Busbar System Current Consumer supply technology Distribution and instrument cabinets Powerlizer electronics 7-19 Appendix

21 Fuses fuse-links meter fuse-links Utilization category gl/gg, AC400V Product definition meter fuse-links of the utilization category gl in accordance with VDE 0636 and gg in accordance with IEC and EN Rated voltage: 400V. The fuse-links are set up in shortened insulators. In conjunction with the plug-in current, they form a complete unit with size 1 to 4a dimensions. They are thus suitable for fitting in fuse-bases, strip-fuseways and fuse-disconnectors. Their special surface treatment provides enhanced corrosion protection. The fuse-links are recycable. Applications HRC fuse-links are used for the monitoring of low voltage circuits and allow asymmetrical loading of the distribution network to be monitored. They can be combined with plug-in current and bimetallic current meters to perform current measurements in cable circuits. Product construction DIMENSIONS in accordance with DIN and IEC , available in sizes 1 to 4a. CHARACTERISTICS All characteristics comply with the standard(s) mentioned above. INSULATOR Steatite CONTACT BLADE Silver-plated surface. GRIPPING-LUGS Live INDICATOR Flap indicator on the upper cover plate. 7-20

22 Size Rated current Std.P Type Article No. MSMK... Size 1 80A 1 1GL80 M4 Size 1 A 1 1G00 M4300 Size 1 125A 1 1G25 M4600 Size 1 160A 1 1G60 M4900 Size 1 200A 1 1G00 M5200 Size 1 250A 1 1G50 M5600 Size 2 80A 1 2GL80 M2004 Size 2 A 1 2G00 M Size 2 125A 1 2G25 M Size 2 160A 1 2G60 M Size 2 200A 1 2G00 M Size 2 250A 1 2G50 M Size 2 315A 1 2G15 M Size 2 400A 1 2GL400 M Size 3 200A 1 3G00 M Size 3 250A 1 3G50 M Size 3 315A 1 3G15 M Size 3 400A 1 3GL400 M Size 3 500A 1 3GL500 M Size 3 630A 1 3GL630 M Size 4a 630A 1 4AGL630 M Size 4a 800A 1 4AGL800 M Size 4a 0A 1 4AG000 M Size 4a 1250A 1 4AG250 M (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) Terminals LV HRC stripfuseways strip-type fusebases C O S M O - 60mm Busbar System Current Consumer supply technology Distribution and instrument cabinets Powerlizer electronics 7-21 Appendix

23 Fuses fuse-links meter fuse-links Utilization category gtr, AC400V Product definition meter fuse-links of the utilization category gtr in accordance with VDE 0636 Part Rated voltage: 400V. The fuse-links are set up in shortened insulators. In conjunction with the plug-in current, they form a complete unit with size 1 to 4a dimensions. They are thus suitable for fitting in LV HRC fuse-bases, strip-fuseways and fuse-disconnectors. Their special surface treatment provides enhanced corrosion protection. The fuse-links are recycable. Applications HRC fuse-links are used for the monitoring of low voltage circuits and allow asymmetrical loading of the distribution network to be monitored. They can be combined with plug-in current and bimetallic current meters to perform current measurements at outgoing transformer units. Product construction DIMENSIONS in accordance with DIN and IEC , available in sizes 1 to 4a. CHARACTERISTICS All characteristics comply with the standard(s) mentioned above. INSULATOR Steatite CONTACT BLADE Silver-plated surface GRIPPING-LUGS Live INDICATOR Flap indicator on the upper cover plate. 7-22

24 Size Transformer rating Std.P Type Article No. MSMK... Size 1 kva 1 1TT4(KVA) M Size 1 125kVA 1 1TT180(125KVA) M1305 Size 1 160kVA 1 1TT231(160KVA) M Size 2 kva 1 2TT4(KVA) M Size 2 125kVA 1 2TT180(125KVA) M2305 Size 2 160kVA 1 2TT231(160KVA) M Size 2 200kVA 1 2TT289(200KVA) M Size 2 250kVA 1 2TT361(250KVA) M2306 Size 3 125kVA 1 3TT180(125KVA) M3305 Size 3 160kVA 1 3TT231(160KVA) M Size 3 200kVA 1 3TT289(200KVA) M Size 3 250kVA 1 3TT361(250KVA) M3306 Size 3 315kVA 1 3TT455(315KVA) M Size 3 400kVA 1 3TT577(400KVA) M Size 4a 250kVA 1 4ATT361(250KVA) M4306 Size 4a 315kVA 1 4ATT455(315KVA) M Size 4a 400kVA 1 4ATT577(400KVA) M Size 4a 500kVA 1 4ATT722(500KVA) M4307 Size 4a 630kVA 1 4ATT909(630KVA) M Size 4a 800kVA 1 4ATT1155(800KVA) M Size 4a 0kVA 1 4ATT43(0KVA M4308 (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) Terminals LV HRC stripfuseways strip-type fusebases C O S M O - 60mm Busbar System Current Consumer supply technology Distribution and instrument cabinets Powerlizer electronics 7-23 Appendix

25 Fuses fuse-links meter fuse-links Fuse-link / current transformer combination Product definition Combination of meter fuse-links and current. Rated voltage: AC400V. The combination of meter fuse-links and plug-in current forms a complete unit with size 1 to 4a dimensions in accordance with VDE The table opposite shows possible combinations for various applications. Other combinations are available on request. Applications Fuse/transformer combinations are used for the monitoring of low voltage circuits and allow asymmetrical loading of the distribution network to be monitored. They can be combined with plug-in current and bimetallic current meters to perform current measurements at and cable circuits. Product construction CHARACTERISTICS All characteristics comply with the standard(s) mentioned above. INSULATOR Steatite CONTACT BLADE Silver-plated surface GRIPPING-LUGS Live INDICATOR Flap indicator on the upper cover plate. CURRENT TRANSFORMER Class 3.../5A, dual-range combination MEASURING DEVICE Bimetallic, with slave pointer, setting time 8min. (standard) or 15min. (class 3), dial marking 0-% (120%), dual-range dial 7-24

26 Rated current of fuse Transformer current Size Utilization category Plug distance Std.P Type Article No. MSMK A 300/150/5A Size 1 gl/gg 42mm 1 1G50-300/150/5 M A 300/150/5A Size 2 gl/gg 50mm 1 2G15-300/150/5 M A 400/200/5A Size 2 gl/gg 50mm 1 2GL /200/5 M A 300/150/5A Size 3 gl/gg 50mm 1 3G15-300/150/5 M A 400/200/5A Size 3 gl/gg 50mm 1 3GL /200/5 M A 600/300/5A Size 3 gl/gg 50mm 1 3GL /300/5 M A 600/300/5A Size 4a gl/gg 72mm 1 4AGL /300/5 M A 800/400/5A Size 4a gl/gg 72mm 1 4AGL /400/5 M A 0/500/5A Size 4a gl/gg 72mm 1 4AG000-0/500/5 M A 1200/600/5A Size 4a gl/gg 72mm 1 4AG /600/5 M Rated current of fuse Transformer current Size Utilization category Plug distance Std.P Type Article No. MSMK A 300/150/5A Size 1 gtr 42mm 1 1TT /150/5(160KVA) M A 300/150/5A Size 2 gtr 50mm 1 2TT /150/5(200KVA) M A 400/200/5A Size 2 gtr 50mm 1 2TT /200/5(250KVA) M A 300/150/5A Size 3 gtr 50mm 1 3TT /150/5(200KVA) M A 400/200/5A Size 3 gtr 50mm 1 3TT /200/5(250KVA) M A 600/300/5A Size 3 gtr 50mm 1 3TT /300/5(400KVA) M A 600/300/5A Size 4a gtr 72mm 1 4ATT /300/5(400KVA) M A 800/400/5A Size 4a gtr 72mm 1 4ATT /400/5(500KVA) M A 0/500/5A Size 4a gtr 72mm 1 4ATT909-0/500/5(630KVA) M A 1200/600/5A Size 4a gtr 72mm 1 4ATT /600/5(800KVA) M (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) Terminals LV HRC stripfuseways strip-type fusebases C O S M O - 60mm Busbar System Current Consumer supply technology Distribution and instrument cabinets Powerlizer electronics 7-25 Appendix

27 Fuses fuse-links meter fuse-links Measuring devices and current Product definition The measuring devices are equipped with a bimetallic measurement mechanism (overload capacity up to 20%) with slave pointer. Dial marking: 0-% (120%), dual-range dial. Setting time: 8min. (standard) or 15min. (accuracy class 3). The current are dual-range measurements. Due to their low overcurrent factor, they can be operated with open secondary sockets. Accuracy class 3.../5A. Applications In conjunction with current, measuring devices are used for the monitoring of low voltage circuits and allow asymmetrical loading of the distribution network to be monitored. They can be combined with plug-in current and bimetallic current meters to perform current measurements at and cable circuits. 7-26

28 Type of device Size Indication/current Response time Plug distance Std.P Type Article No. Transformers Size 1 200//5A - 42mm 1 MSMK1/200//5 M Transformers Size 1 300/150/5A - 42mm 1 MSMK1/300/150/5 M Transformers Size 2 300/150/5A - 50mm 1 MSMK2/300/150/5 M Transformers Size 2 400/200/5A - 50mm 1 MSMK2/400/200/5 M Transformers Size 3 400/200/5A - 50mm 1 MSMK3/400/200/5 M Transformers Size 3 600/300/5A - 50mm 1 MSMK3/600/300/5 M Transformers Size 4a 600/300/5A - 72mm 1 MSMK4A/600/300/5 M Transformers Size 4a 800/400/5A - 72mm 1 MSMK4A/800/400/5 M Transformers Size 4a 0/500/5A - 72mm 1 MSMK4A/0/500/5 M Transformers Size 4a 1200/600/5A - 72mm 1 MSMK4A/1200/600/5 M Bimetallic instrument Size 1 200//5A 8min. 42mm 1 MQS0SO42(200//5A) M Bimetallic instrument Size 1 300/150/5A 8min. 42mm 1 MQS0SO42(300/150/5A) M Bimetallic instrument Sizes 2/3 300/150/5A 8min. 50mm 1 MQS0SO50(300/150/5A) M Bimetallic instrument Sizes 2/3 400/200/5A 8min. 50mm 1 MQS0SO50(400/200/5A) M Bimetallic instrument Sizes 2/3 600/300/5A 8min. 50mm 1 MQS0SO50(600/300/5A) M Bimetallic instrument Sizes 2/3 300/150/5A 15min. 50mm 1 MQS0SO50(300/150/5A) M Bimetallic instrument Sizes 2/3 400/200/5A 15min. 50mm 1 MQS0SO50(400/200/5A) M Bimetallic instrument Sizes 2/3 600/300/5A 15min. 50mm 1 MQS0SO50(600/300/5A) M Bimetallic instrument Size 4a 600/300/5A 15min. 72mm 1 V-MQS096SO72(600/300/5A) M Bimetallic instrument Size 4a 800/400/5A 15min. 72mm 1 V-MQS096SO72(800/400/5A) M Bimetallic instrument Size 4a 0/500/5A 15min. 72mm 1 V-MQS096SO72(0/500/5A) M Bimetallic instrument Size 4a 1200/600/5A 15min. 72mm 1 V-MQS096SO72(1200/600/5A) M (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) Terminals LV HRC stripfuseways strip-type fusebases C O S M O - 60mm Busbar System Current Consumer supply technology Distribution and instrument cabinets Powerlizer electronics 7-27 Appendix

29 650 SL00-3X/..., SL00-3X3/... Ordering details see page HA-S HA-S23 SL...-3x(3)... Ordering details see page

30 HA-S max (SASIL) (cut ut dimensi n min.) 635 (cut ut dimensi n max.) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) Terminals 26 HA-S23 52 SL...-3x/.../GV Ordering details see page 7-5 LV HRC stripfuseways strip-type 7 fusebases C O S M O - 60mm Busbar System Current Consumer supply technology 50 Distribution and instrument cabinets S-3X(3)/.../ARO Ordering details see page 7-5 Powerlizer electronics 7-29 Appendix

31 7-30 S-3X(3)/0/HA Ordering details see page AO AU S-3X(3)/910/AO/AU- Ordering details see page 7-5

32 (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) 94.5 Terminals AU AO S-3X(3)/910/AO/AU-65 LV HRC stripfuseways Ordering details see page strip-type fusebases C O S M O - 60mm Busbar System Current Consumer supply technology AU AO Distribution and instrument cabinets S-3X(3)/910/AO/AU-75 Ordering details see page 7-5 Powerlizer electronics 7-31 Appendix

33 max (cut out dimension min.) 635 (cut out dimension max.) S-3x(3)/910/ARO/110 Ordering details see page 7-5 HA220-S max (cut out dimension min.) 635 (cut out dimension max.) HA220-S S-3X/910/HA Ordering details see page

34 , Ø (SASIL) Ø fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) 153, Terminals Ø18 S-3x(3)/910/AORL Ordering details see pages 7-5; 7-9 LV HRC stripfuseways , ,5 24, strip-type Ø13 fusebases Ø 879 C O S M O - 60mm Busbar System Current 153, Consumer supply technology Ø18 40 Distribution and instrument cabinets S-3x(3)/910/AORK Ordering details see pages 7-5; 7-9 Powerlizer electronics 7-33 Appendix

35 , , M12x Ø , S-3X/910/AO-102 Ordering details see pages 7-5; M12x S-3x2(3x6)/.../HA Ordering details see page

36 (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) 22 M16 SLTL4A-3AS/3x/4/(AO) Terminals LV HRC stripfuseways Ordering details see page 7-6 strip-type fusebases C O S M O - 60mm Busbar System Current 60 M12 Consumer supply technology Distribution and instrument cabinets 227 SLTL4A-3AS/3X/2X3A/Q/7K/AO Ordering details see page 7-6 Powerlizer electronics 7-35 Appendix

37 Ø SL00-3X3//F/ES00 Ordering details see page Ø x SL00-3X3//... Ordering details see page

38 HA-S (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) Terminals S-3x3/... HA-S23 Ordering details see page 7-5, 7-9 LV HRC stripfuseways 202 strip-type HA-S fusebases Ø 285 C O S M O - 60mm Busbar System 341 Current 40 Consumer supply technology 26 51,5 Distribution and instrument cabinets SL...-3X3/3A/ES00 Ordering details see page 7-9 Powerlizer electronics 7-37 Appendix

39 max (cut ut dimensi n max.) 570 (cut ut dimensi n min.) S-3x(3)/910/ARUS Ordering details see page M12x S-3X6/1250(1600)/HA Ordering details see page

40 max (SASIL) 635 (cut ut dimensi n max.) 570 (cut ut dimensi n min.) SL SR fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) 99 Terminals SLT3-3SL(SR)/3x(3)/... LV HRC stripfuseways Ordering details see page , , strip-type fusebases M12 C O S M O - 60mm Busbar System Current Consumer supply technology 200 Distribution and instrument cabinets SLT3-3SR/3x2(3x6)/2000 Ordering details see page Powerlizer electronics 7-39 Appendix

41 M16 SW8 M16 SW8 88 max max K3G/3/AF40-50 Ordering details see page 7-18 K3G/4/AF40-50 Ordering details see page 7-18 M12 SW6 M12 SW max max KV2HG-F/2/300/AF40-50 Ordering details see page 7-18 K2G/A Ordering details see page

42 15 15 (SASIL) fuses (SASIL) BS M5 M5 (SASIT) DIN and BS s (SALIT) Terminals 25 P0070-Z Ordering details see page 7-18 S00-Z Ordering details see page 7-18 LV HRC stripfuseways strip-type 25,5 SW4 fusebases A C O S M O - 60mm Busbar System Current 18,5 26, SK-SL00/10 SK-SL00/15 A Consumer supply technology 71 Distribution and instrument cabinets FK2x240-S3 Ordering details see page 7-15 SK-SL00 Ordering details see page 7-16 Powerlizer electronics 7-41 Appendix

43 M8 20,5 M8 M8 M12 25 AB-SL00/1 Ordering details see page 7-15 AB-SL00//1/52 Ordering details see page SW SW SW19 60 M12 25 M M AB60-SL00//1 Ordering details see page 7-15 AL-SL00/42 Ordering details see page

44 SW ,5 SW6 (SASIL) 20, M fuses (SASIL) BS M8 (SASIT) DIN and BS s M8 (SALIT) , Terminals AL-SL00//52 Ordering details see page 7-16 AL/SK-SL00//52 Ordering details see page 7-16 LV HRC stripfuseways strip-type fusebases M C O S M O - 60mm Busbar System Current Consumer supply technology 99, Distribution and instrument cabinets AL/SK-SL00/42 Ordering details see page 7-16 HRV-KM2.../Gelb Ordering details see page 7-16 Powerlizer electronics 7-43 Appendix

45 HA-SL00 Ordering details see page 7-16 HA-S23/10 Ordering details see page HA-SX2/10 Ordering details see page 7-16 HA220-S23/10 Ordering details see page

46 49 55,5 (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) 39,5 Terminals HA275-S23/10 Ordering details see page 7-16 HAV-SL00/ Ordering details see page 7-5 LV HRC stripfuseways strip-type 30 fusebases 135 BO C O S M O - 60mm Busbar System Current 227 BU Consumer supply technology Distribution and instrument cabinets BO/BU-SL00/ Ordering details see page 7-16 B-SL00/ Ordering details see page 7-16 Powerlizer electronics 7-45 Appendix

47 , , ,5 49 B-SL00/633 Ordering details see page 7-16 B-SL00/650 Ordering details see page B-S23/633 Ordering details see page 7-16 H-RF Ordering details see page

48 (SASIL) fuses (SASIL) BS (SASIT) DIN and BS s M M (SALIT) Terminals H-SL00 H-SL00/ LV HRC stripfuseways Ordering details see page 7-17 Ordering details see page strip-type fusebases C O S M O - 60mm Busbar System M12 M12 Current Consumer supply technology Distribution and instrument cabinets H-S23/662 Ordering details see page 7-17 H-S23/ST Ordering details see page 7-17 Powerlizer electronics 7-47 Appendix

49 LA-SL00 LA-S23 Ordering details see page 7-17 Ordering details see page , AH-SL AH-SL/S Ordering details see page 7-17 Ordering details see page

50 .5 (SASIL) 665 fuses (SASIL) BS (SASIT) DIN and BS s (SALIT) Terminals AHCT-SL00-3 Ordering details see page 7-17 BZO-SL00 Ordering details see page 7-17 LV HRC stripfuseways strip-type fusebases C O S M O - 60mm Busbar System M Current Consumer supply technology Distribution and instrument cabinets BZO-S23/10 Ordering details see page OW/-L/S23 Ordering details see page 7-17 Powerlizer electronics 7-49 Appendix

6-0. Product family. LV HRC strip-fuseways

6-0. Product family. LV HRC strip-fuseways Product family strip-fuseways strip-fuseways in accordance with DIN 43623 are mainly used for power distribution in cable distribution cabinets and low voltage power supply distribution systems. They are

More information

mainly used for power distribution

mainly used for power distribution Product family strip type fuse-switch-disconnector strip type fuseswitch-disconnectors are mainly used for power distribution in low voltage assemblies in accordance with IEC/EN 60439-1. The strips are

More information

Size 00-4a LV HRC fusebases. plates and for direct mounting on busbars. In addition, they serve as bases for LV HRC fuselinks

Size 00-4a LV HRC fusebases. plates and for direct mounting on busbars. In addition, they serve as bases for LV HRC fuselinks Product family fuse-bases Size 00-4a fusebases are suitable for surface mounting on mounting plates and for direct mounting on busbars. In addition, they serve as bases for fuselinks in accordance with

More information

Vertical fuse disconnects

Vertical fuse disconnects THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric

More information

9-0. Product family. LV HRC fuse switch-disconnectors. Surface mounting Busbar mounting

9-0. Product family. LV HRC fuse switch-disconnectors. Surface mounting Busbar mounting Product family fuse switch-disconnectors The 9 series fuse switch-disconnectors of the DIN sizes 00-4a are suitable for surface mounting on mounting plates and for direct mounting on busbars. The different

More information

Vertical fuse disconnects

Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric circuits under

More information

Standardized fuse characteristics

Standardized fuse characteristics Product family "Fuses offer unique advantages compared to other protective devices." Standardized fuse characteristics and high current limitation guarantee easy and reliable coordination between HV HRC

More information

Strip type fuse-switch-disconnectors

Strip type fuse-switch-disconnectors Strip type fuse-switch-disconnectors NV Strip type fuse-switch-disconnector sizes 00, 1, 2, Characteristics of the NV Strip type fuse-switch-disconnectors The NV Strip type fuse-switch-disconnectors are

More information

LV HRC fuse switch-disconnectors

LV HRC fuse switch-disconnectors The 9 series LV HRC fuse switch-disconnectors of the DIN sizes 00-4a are suitable for surface mounting on mounting plates and for direct mounting on busbars. The different sizes are available as 1-pole,

More information

Product family. D type fuse-links

Product family. D type fuse-links Product family D type fuse-links Fuses offer unique advantages compared to other protective devices. 3-0 Due to their compact dimensions, D type fuses from JEAN MÜLLER provide economical overcurrent protection

More information

Vertical fuse disconnects

Vertical fuse disconnects THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fusecarriers enable opening and closing operation in electric

More information

BETA Fuses and Fuse Systems

BETA Fuses and Fuse Systems Introduction Overview Application LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in the switchboards of power supply companies. Fuses

More information

Utilisation category gl/gg 500VAC with combi indicator

Utilisation category gl/gg 500VAC with combi indicator DIN-fuse-links DIN fuse-links are used for the protection of electrical installations and equipment and are common for a wide area of applications. Standardised characteristics, technical data and dimensions

More information

2013 JEAN MÜLLER Products

2013 JEAN MÜLLER Products 2013 JEAN MÜLLER Products Company JEAN MÜLLER JEAN MÜLLER was founded in 1897 in Germany, when the applications of electricity were still in their very early days. The company chose as its basic activity

More information

Horizontal fuse disconnects

Horizontal fuse disconnects THE NAME FOR SAFETY Horizontal fuse disconnects Horizontal fuse disconnects Horizontal fuse Disconnects are used in building installations, switchgear and controlgear as well as in power utility networks.

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

PANEL PANEL MOUNTING COMPONENTS

PANEL PANEL MOUNTING COMPONENTS PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

60mm-System classic 630A (800A) / 2500A

60mm-System classic 630A (800A) / 2500A 60mm-System classic 630A (800A) / 500A System Benefits The small external dimensions of the 60mm busbar system allow for a wide range of busbars, so that it can be easily adapted to a wide range of currents.

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Thermostats Filters and Fans Terminals Electrical Cabinet Heating Catalogue 2016 Fuse Switch Disconnectors XNH Fuse

More information

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K Varius SUMMARY OF MODELS OF FUSE-RAILS Type FSR00 FSR1 FSR2 FSR3 Rated operating current I e 160 A 250 A 400 A 630 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V Size 00 1 2 3 Busbar spacing

More information

MULTIVERT 250A Size 1, 690VAC

MULTIVERT 250A Size 1, 690VAC MULTIVERT 250A IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors.

More information

185mm-System power 2500A. Expertise

185mm-System power 2500A. Expertise 185mm-System power 2500A Expertise System advantages The 185mm-System power is designed for use in efficient power distribution assemblies with a high short-circuit withstand capacity. The narrow design

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

NH-Fuse system Low voltage

NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr Seite 3 NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 14:01 Uhr Seite 2 Utilization NH-fuses gg am gtr NH-fuses Utilization Categories

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

System Benefits Should you have any further questions, please contact our UL hotline at: +49 (0)9563/ Connection Technology EQUES Technology

System Benefits Should you have any further questions, please contact our UL hotline at: +49 (0)9563/ Connection Technology EQUES Technology System Benefits The small external dimensions of the 60mm busbar system allow for a wide range of busbars, so that it can be easily adapted to a wide range of currents. These features result in the particularly

More information

INNOVATION IS OUR POWER.

INNOVATION IS OUR POWER. MANUAL 2019 EN INNOVATION IS OUR POWER. Wöhner develops system solutions for the electro-technical market. For over 90 years, the Wöhner name has been synonymous with impressive technical achievements

More information

Type Pack size Weight Part no. kg/100 units for undrilled busbars 30, 40, 50, 60 x 10. Dimensions Current Pack size Weight Part no.

Type Pack size Weight Part no. kg/100 units for undrilled busbars 30, 40, 50, 60 x 10. Dimensions Current Pack size Weight Part no. 1 01 628 01 617 01 79 01 25 Universal busbar support 100mm, 3-pole Type Pack size Weight Part no. for undrilled busbars 30, 0, 50, 60 x 10 7.1 01 79 06 End cover for busbar support 01 79 10 5.3 01 25 06

More information

BETA Low-Voltage Circuit Protection

BETA Low-Voltage Circuit Protection BETA Low-Voltage Circuit Protection /2 Introduction Miniature Circuit Breakers /4 5SP and 5SY miniature circuit breakers / 5SJ6...-.KS miniature circuit breakers with plug-in terminal /21 5SY6 0 miniature

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

8WH2 Spring-Loaded Terminals

8WH2 Spring-Loaded Terminals 8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards ALPHA 400 - DIN Wall-Mounted Distribution Boards /2 Introduction Unequipped Distribution Boards (Flat Pack) /6 8GK1 surface-mounting distribution boards Pre-Assembled Unequipped Distribution Boards /7

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Comb busbars. Description Part No. $NZ

Comb busbars. Description Part No. $NZ Comb busbars FTG comb type busbars are constructed of three copper conductors within a single moulding for connection to Jean Müller LTL000-3/9 or LTL00-3/9 horizontal fuse disconnects. The busbar is rated

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

MANUAL 2018 AL 2018 U AN M

MANUAL 2018 AL 2018 U AN M MANUAL 2018 DEVELOPED IN RÖDENTAL, SUCCESSFUL WORLDWIDE Wöhner develops system solutions for the electro-technical market. For over 88 years, the Wöhner name has been synonymous with impressive technical

More information

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple

More information

CRITO Connection technology. Double and triple T and TCC section busbars

CRITO Connection technology. Double and triple T and TCC section busbars Centre feed unit 5 Centre feed unit Centre feed unit 5 Centre feed unit up to 4000 A combines the advantages of high short-circuit capacity, drill-free mounting, brace terminal technology and clearly structured

More information

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom

More information

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc. Chapter 3 TRANSMISSION SYSTEMS 1 Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution

More information

CENTRE FEED UNIT UP TO 4000A. Safety

CENTRE FEED UNIT UP TO 4000A. Safety CENTRE FEED UNIT UP TO 000A Safety Centre feed unit New TCC section busbar: Connection options with CRITO PowerClip and CRITO ProfiClip, and terminal studs (screw in c-slot). 1-pole, side busbar support

More information

Practical and completely safe

Practical and completely safe FUSE RRIERS >>> Practical and completely safe Isolating fuse carriers 058 06 058 28 Dimensions (p. 0) onform to standard IE 60269-2/2. and to NF 63-2. Isolators conform to IE 60947-3. Icc: - 20 k with

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

Switch disconnectors and fuse switch disconnectors

Switch disconnectors and fuse switch disconnectors Switch disconnectors and fuse switch disconnectors Technology QUADRON CrossLinkBreaker Secures and disconnects currents up to 100A Sizes 000 to 2 can be mounted quickly on DIN EN 50 022 rails using the

More information

MC FRAME SIZE 1 / UP TO 160A

MC FRAME SIZE 1 / UP TO 160A 8 W CIRCUIT BREAKER 3 POLE UP TO 160A WITH THERMAL MAGNETIC RELEASE TYPES MC1B-A, MC1N-A, MC1H-A For system and line protection Adjustable overload release Ir: 0,8 1 x In (factory setting 0,8 x In) Adjustable

More information

Molded-Plastic Distribution Systems

Molded-Plastic Distribution Systems Molded-Plastic Distribution Systems / Introduction ALPHA 8HP molded-plastic distribution systems /8 Empty enclosures / Modular installation devices /4 DIAZED/NEOZED fuse systems /7 NP fuse switch disconnectors

More information

8WH2 Spring-Loaded Terminals

8WH2 Spring-Loaded Terminals 8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

PANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality

PANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality PANEL-MOUNTING COMPONENTS FUSE HOLDERS Quality For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated

More information

NH DIN Dual Indication Fuse Links

NH DIN Dual Indication Fuse Links Class of Operation gl/gg, 500V AC, 10 to 630 s Sizes 000 to 3 Standards/ Approvals: Description: Packaging: IEC 60269, VDE0636, DIN 43 620 1 to 4. A square bodied range of industrial fuse links for a wide

More information

In-line Plug-in Design 3NJ6

In-line Plug-in Design 3NJ6 Contents Page - Outgoing Feeders General 6/2 Structure and Functions inclusive Forms of Internal Separation, Installation of Instruments 6/2 Plug-on Bus System 6/2 Cable Connection Compartment 6/2 Switch-disconnector-fuse

More information

MULTIVERT 1000A Main Incomer, 690VAC

MULTIVERT 1000A Main Incomer, 690VAC IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed

More information

Varius SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS. Type SPB S3PB SPF SP4.. SP50

Varius SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS. Type SPB S3PB SPF SP4.. SP50 SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS Type SPB SPB SPF SP4.. SP50 Rated current I n 60 A / 0 A / 400 A 60 A / 0 A / 400 A 60 A / 0 A / 400 A / / 60 A Rated voltage AC/DC U n 690 V 690 V 690 V

More information

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components Supersedes July 2002 Contents Page Procedure for identifying parts... 2 Customer ordering instructions.... 2 Distributor ordering instructions.... 2 Front panel components.... 3 Breaker pan assembly....

More information

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 2.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 2.ST8 comprises NH fuse switch disconnectors for 400A. They are designed for bottom

More information

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter

More information

FUSE-LINKS GAUGE PIECES FUSE BASES SINGLE-POLE FUSE BASES THREE-POLE FUSE BASES LOW VOLTAGE FUSES POWER NEEDS CONTROL

FUSE-LINKS GAUGE PIECES FUSE BASES SINGLE-POLE FUSE BASES THREE-POLE FUSE BASES LOW VOLTAGE FUSES POWER NEEDS CONTROL D FUSE-LINKS GAUGE PIECES D FUSE BASES SINGLE-POLE FUSE BASES THREE-POLE FUSE BASES LOW VOLTAGE FUSES POWER NEEDS CONTROL 57 FUSE-LINKS D D type fuse-links are used to protect electric, signal and control

More information

NH LOW VOLTAGE a FUSE SYSTEM

NH LOW VOLTAGE a FUSE SYSTEM NH LOW VOLTAGE a FUSE SYSTEM NH DIN Low Voltage Fuse System from Cooper Bussmann High Breaking Capacity 400Vac, 500Vac and 690Vac Insulated Tag variants available Dual Indication VDE 066 Part 1 DIN 4 60

More information

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002 Overload Relays, Motor-Protective Relays Overview 06/00 Overload relays, motor-protective relays Page Technical overview 06/00 System overview 05/006 Overload relays, motor-protective relays 06/004 ZE,

More information

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs) Introduction Overview Devices Page Application Standards Used in / Personnel, material and fire protection, as well as protection against direct contact. SIGRES with active condensation protection for

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

MR - MEDIUM RATING A

MR - MEDIUM RATING A 88 MR - MEDIUM RATING 160-1000A SECTION CONTENTS 90 General features 96 Advantages 100 Illustrated contents MR MEDIUM RATING 102 Trunking components 110 Feed units and end covers 113 Tap-off boxes 118

More information

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application s SICOP Bimetal Overload Relays Type 3UA5/6 & 3UC5/6 Introduction The bimetal overload relays type 3UA5/6 & 3UC5/6 relays are indigenously manufactured and bring to the users a whole range of benefits,

More information

One Source. Fuse monitoring for NH Fuse-Bases or Fuse-Rails

One Source. Fuse monitoring for NH Fuse-Bases or Fuse-Rails One Source Insulator Clamps for devices Fuse monitoring for NH Fuse-Bases or Fuse-Rails Solid links MM: Bild angeben Content NH Replacement Handles 192 NH Solid-Links 192 Fuse-Monitoring with strikers

More information

Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip

Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip Project Number: PAL -10-00063805 Project Name: Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip Bill of Quantities Package # 2 LOT 2: Supply of Electrical Materials The contract

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

18-1. LV- HRC fuselinks HV- D- type fuselinks. D- type fusebases. Switchdisconnectorfuses. (SASIL) LV HRC system. BS system.

18-1. LV- HRC fuselinks HV- D- type fuselinks. D- type fusebases. Switchdisconnectorfuses. (SASIL) LV HRC system. BS system. Appendix Semiconductor protection fuselinks / information Distribution and instrument cabinets / current carrying capacity Distribution and instrument cabinets / condensation Distribution and instrument

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S MOULDED CASE CIRCUIT BREAKERS BH6N, BH6S F BH6N, BH6S COMMERCIAL INFORMATION Switching units, withdrawable device, plug-in device...f4 Switch-disconnector unit...f6 Connecting sets...f7 Mounting sets...f9

More information

NH DIN Dual Indication Fuse Links

NH DIN Dual Indication Fuse Links Class gg/gl, 400Vac, 2 to 630 Amps, Sizes 000 to 3 Standards/Approvals IEC 60269, VDE 0636, DIN 43620 Part 1 and 3 Description A square bodied range of industrial fuse links for a wide variety of applications.

More information

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment General The switchgear must be suitable for 36 kv rated voltage and specifically conceived for the secondary distribution substations in M.V. with either ring or radial type networks. The switchgear must

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs) Product overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristic Rated currents I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SX2

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

System Manual 02/2008

System Manual 02/2008 System Manual 02/2008 SIRIUS Infeed System for 3RA6 sirius COMPACT STARTER Introduction 1 Product-specific information 2 SIRIUS industrial switchgear Load feeders, motor and soft starters System Manual

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

Energy Australia Chamber Substation indoor switchgear. installation,operation and maintenance instructions version 1.

Energy Australia Chamber Substation indoor switchgear. installation,operation and maintenance instructions version 1. Energy Australia Chamber Substation indoor switchgear installation,operation and maintenance instructions version 1.6 / February 2009 1 Details of revision Version Comment Date 1.0 First Draft Issue May

More information

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE Certificate Number FM35831 APPLICATION Typical Uses and Classification The MSGair switchgear is used in transformer and switching substations mainly

More information

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv] BasisBlock MC 1 Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC1-12 MC1-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage

More information

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

CATALOG. EasyLine XLP Fuse Switch Disconnector poles CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5 .1 AZM 11 range Features Thermoplastic enclosure Manual and emergency release Long life Double insulated X High holding force, N N latching force Wiring compartment Actuation on de-energisation or energisation

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC6N Tento výrobek byl vyvinut za finanční podpory ze státních fondů prostřednictvím Ministerstva průmyslu a obchodu. D BC6N COMMERCIAL INFORMATION Circuit breakers...d4

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33

More information

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec Catalog HA 41.43 Edition 2018 Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear siemens.com/simosec Application Typical uses R-HA41-135.tif R-HA40-112.tif R-HA41-115.tif

More information

PANEL-MOUNTING COMPONENTS SWITCHGEAR. Technology

PANEL-MOUNTING COMPONENTS SWITCHGEAR. Technology PANEL-MOUNTING COMPONENTS SWITCHGEAR Technology QUADRON CrossLinkBreaker Disconnects and provides fuse protection for currents up to 100A Sizes 000 to 2 can be mounted quickly on DIN EN 50 022 rails using

More information

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors Fuse monitoring possible throughout Busbar supports can be

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 0 A 08 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket

More information