OSIGURAČ-RASTAVNE SKLOPKE FUSE - SWITCH DISCONNECTORS

Size: px
Start display at page:

Download "OSIGURAČ-RASTAVNE SKLOPKE FUSE - SWITCH DISCONNECTORS"

Transcription

1 SIGURČ-RSTVNE SKLPKE FUSE - SWITCH DISCNNECTRS J0 /

2 PIS DESCRIPTIN sigurač-rastavne sklopke su niskonaponski sklopni aparati koji omogućavaju sigurno uklapanje i isklapanje električnih strujnih krugova pod teretom, ovisno o naponu i kategoriji upotrebe, a osnovna namjena im je zaštita električne opreme od kratkog spoja i preopterećenja korištenjem nožastih uložaka osigurača vel. 000 ( 00C ) i vel. 00. Ukoliko se osigurač-rastavna sklopka koristi bez uložaka osigurača, tj. sa kratkospojnicima, tada ima funkciju rastavnesklopke koja u otvorenom položaju zadovoljava izolacijske zahtjeve određene za rastavljač. Fuse-switch disconnectors are low-voltage switching devices which enables safely manual connecting and disconnecting electrical circuits under load, depending on voltage and utilization category. Their purpose is protection of low voltage electrical equipment against specified overload and short circuit using fuse-links size 000 ( 00C) and size 00. It can be used with disconnecting knives and then have function of switch-disconnector. Područje primjene pplication Svoju primjenu osigurač-rastavne sklopke pronalaze u svim područjima niskoga napona, kako u industriji, tako i u kućanstvima: - razvodna polja u pogonima - javna rasvjeta ( ormari javne rasvjete ) - napajanje kućanstava ( kućni priključno mjerni ormari ) itd. Fuse-switch disconnetors are intended for: - distribution boards, distribution panels - public lightening cabinets - operation at the point of supply between the public network distribution and the cunsumer s installation Dizajn Design Specijalno oblikovani i zaštićeni lira kontakti, zajedno sa lučnim komorama, omogućuju visoku sklopnu moć, te su garancija visoke električne i mehaničke trajnosti. Svi kontaktni dijelovi izrađeni su od posrebrenog bakra. Special designed and protected lyra contact with arching chambers enable high switching capacity and they are guarantee of high electrical and mechanical durability. ll contact parts are made of silver- plated copper. Priključak Connections Priključak osigurač-rastavne sklopke predviđen je, kako za direktan priključak kablova ( obuhvatna stezaljka S00, prizma stezaljke P00, P002, stezni okvir -00 ), tako i za kabele sa kabelskim stopicama ( vijak M8 ). The connections of fuse-switch disconnector are made for direct terminal clamps ( clip type terminal S00, prism clamp P00, prism clamp P002, box terminal -00 ), and for cable with cable lugs ( screw M8 ). Montaža Mounting sigurač-rastavna sklopka montira se direktno na montažnu ploču ( vijak M ) ili na profilne nosače mm ( DIN EN 0022 ). Montira se u vertikalnom položaju. Fuse-switch disconnector can be mounted on mounting board ( screw M ) or can be snapped onto mm mounting rails ( DIN EN 0022 ). Mounting in vertical position. Norme Standards sigurač-rastavna sklopka zadovoljva sljedeće norme: - IEC IEC 9- - IEC IEC Fuse-switch disconnector is in accordance with next standards: - IEC IEC 9- - IEC IEC Temperatura okoline, klimatski utjecaji mbient temperature sigurač-rastavna sklopka tip S-00C može se koristiti pri temperaturama okoline od -2C do +C, do 2000m nadmorske visine. Namjenjena je za primjenu u područjima bez prisustva agresivnih i eksplozivnih plinova. Fuse-switch disconnector type S-00C can be used from -2C to +C ambiental temperature up to 2000m altitude. Fuse-switch disconnector to be used in area without aggressive and explosive gases. 2

3 VELIČIN / SIZE (000) 00C Tip/ Type S-00C/1 Pribor/ ccessories pis / Description Nar. broj / rder Code Jednopolno rastavljiva sigurač - rastavna sklopka Single - pole Fuse - switch disconnector Tip*/ Type* pis / Description Nar. broj / rder Code Zaštitne kape za sigurač rastavnu sklopku Tip: S-00C/1;S-00C/2; S-00C/ Protecting covers for Fuse switch disconnector Type: S-00C/1; S-00C/2; S-00C/ 0Z21 ZK-00C/1 0Z29 S-00C/2 Dvopolno rastavljiva sigurač - rastavna sklopka Two - pole Fuse - switch disconnector ZK-00C/1 + ZK-00C/1 0Z21 S-00C Zaštitne kape za sigurač rastavnu sklopku Tip: S-00C; S-00C/; Tropolno rastavljiva sigurač - rastavna sklopka Three - pole Fuse - switch disconnector ZK-00C/ Protecting covers for Fuse switch disconnector Type: S-00C; S-00C/; 0Z290 S-00C/ 0Z21 ZK-00C/1 + ZK-00C/ *Isporučuju se kape za zaštitu gornjih i donjih priključaka *Protecting covers for protection of top and bottom terminals Tropolno rastavljiva sigurač - rastavna sklopka za sabirnički sustav mm Three - pole Fuse - switch disconnector ZK-00C/S for busbar system mm 0Z12 Zaštitne kape za sigurač rastavnu sklopku Tip: S-00C/S; S-00C/S Četveropolno rastavljiva sigurač - rastavna sklopka Four - pole Fuse - switch disconnector 0Z222 S-00C/S Protecting covers for Fuse switch disconnector Type: S-00C/S; S-00C/S Tropolno rastavljiva sigurač - rastavna sklopka za sabirnički sustav mm: Stezni okvir -00 S-00C/S Three - pole Fuse - switch disconnector ZK-00C/S for busbar system mm: Box terminal -00 0Z12 0Z21 TIPVI PRIKLJUČK / TYPES F TERMINLS PRIBR / CCESSRIES Priključak Terminal Tip/Type Nar.br/rder code Priključni presjek Clamping range Vijak Screw M8 00 S00 (-1) S00 (2-0) P00 (10-) P00 (0-0) P002 (10-1) P002 (2-) P002 (0) 0Z01 0Z0 0Z0 0Z0 0Z0 0mm2-0mm2 ( - 1)mm2 (2-0)mm2 (10 - )mm2 (0-0)mm2 2x(10-1)mm² 2x(2-)mm² Cu Cu M 2 x (Mx12) 2 x (Mx1) M8x12 DIN 9 Moment pritezanja 12-1Nm, Nm Tightening torque Pakiranje (kom) Package (pcs) 0Z02 2, Nm 2 x (Mx20) 2 x (Mx2) 2 x (Mx2) 2, Nm, Nm, Nm, Nm 2 x (Mx0), Nm 0Z0 2x0mm2 2 x (Mx), Nm Napomena: snovna varijanta osigurač-rastavne sklopke isporučuje se sa vijcima M8, a varijanta sa steznim okvirom -00. Note: Basic type of fuse-switch disconnector is delivered with screws M8, type is delivered with Box terminal -00.

4 VELIČIN / SIZE 00 Tip/ Type Pribor/ pis / Description ccessories Nar. broj / rder Code Jednopolno rastavljiva S-00/1 sigurač - rastavna sklopka Single - pole Fuse - switch disconnector 0Z20 Jednopolno rastavljiva sigurač S-00/1 rastavna sklopka: Stezni okvir -00 Single - pole Fuse - switch disconnector: Box terminal -00 0Z12 Tip*/ Type* pis / Description Nar. broj / rder Code Pribor za montiranje na sustav šina razmaka 12mm / 10mm P-00 ccessories for mounting between two standard rails 12mm / 10mm apart 0Z1 Dvopolno rastavljiva S-00/2 sigurač - rastavna sklopka Two - pole Fuse - switch disconnector 0Z18 Dvopolno rastavljiva sigurač S-00/2 rastavna sklopka: Stezni okvir -00 Two - pole Fuse - switch disconnector: Box terminal -00 0Z19 Tropolno rastavljiva sigurač - rastavna sklopka S-00 Three - pole Fuse - switch disconnector 0Z299 Tropolno rastavljiva sigurač S-00 rastavna sklopka: Stezni okvir -00 Three - pole Fuse - switch disconnector: Box terminal -00 0Z22 Četveropolno rastavljiva sigurač - rastavna sklopka S-00/ Four - pole Fuse - switch disconnector 0Z222 Četveropolno rastavljiva sigurač S-00/ rastavna sklopka: Stezni okvir -00 Four - pole Fuse - switch disconnector: Box terminal -00 0Z10 TIPVI PRIKLJUČK / TYPES F TERMINLS PRIBR / CCESSRIES Priključak Terminal Tip/Type Nar.br/rder code Priključni presjek Clamping range M8 00 S00 (-0) P00 (10-0) P00 9 (-9) P002 (10-) P002 (0) 0Z08 0Z09 0Z12 0Z10 0Z11 0mm2-0mm2-0mm2 Cu 10-0mm2-9mm2 2x(10-)mm² 2x0mm2 Vijak Screw M8x12 DIN 9 M 2 x (Mx1) 2 x (Mx2) 2 x (Mx0) 2 x (Mx0) 2 x (Mx0) Moment pritezanja Tightening torque 12-1Nm, Nm 2, Nm, Nm, Nm Pakiranje (kom) Package (pcs), Nm, Nm Napomena: snovna varijanta osigurač-rastavne sklopke isporučuje se sa vijcima M8, a varijanta sa steznim okvirom -00. Note: Basic type of fuse-switch disconnector is delivered with screws M8, type is delivered with Box terminal -00. ZNK Z NRUČIVNJE SIGURČ-RSTVNE SKLPKE RDER DESIGNTIN FR FUSE-SWITCH DISCNNECTR - tip / type Primjer / Example: S-00/1 ZNK Z NRUČIVNJE PRIBR (PRIKLJUČK) RDER DESIGNTIN CCESSRIES (TERMINLS) B B - tip / type Primjer / Example: P002 (10-)

5 TEHNIČKI PDCI / TECHNICL DT S-00C/1 Tip / Type Nazivna termička struja na otvorenom Conventional free air thermal current Nazivni napon izolacije Rated insulation voltage Nazivni podnosivi udarni napon Rated withstand impulse voltage Nazivna frekvencija Rated frequency Kategorija upotrebe Utilization category Nazivna pogonska struja Rated operational ( making and breaking ) current Nazivni pogonski napon Rated operational ( making and breaking ) voltage ( siguračem ) uvjetovana kratkospojna struja Rated conditional short-circuit current Mehanička trajnost ( radni ciklusi ) Mechanical durability ( operating cycles ) Električka trajnost ( radni ciklusi ) Electrical durability ( operating cycles ) Gubici (bez uložaka osigurača) Power dissipation (without fuse-links) Stupanj zaštite ( poklopac zatvoren ) Degree of protection ( cover closed ) Stupanj zaštite ( poklopac otvoren ) Degree of protection ( cover opened ) Stupanj zagađenja Pollution degree Dopuštena radna temperatura okoline Permissible ambient temperature ** Temperatura skladištenja Storage temperature Težina ( bez uložaka osigurača ) Weight ( without fuse-links ) Pakiranje Package S-00C 1 1 V C90 C90 kv 0 ( 0- ) 0 ( 0- ) Hz C-21B C-22B C-21B keff W C90 C00 C00 C20 V C-22B , 10,2 IP20 IP20 IP10 IP10 C C kg kom pcs 0,2 0,8 1 * U slučaju montaže osigurač-rastavne sklopke u ormar potrebno je korigirati termičku struju ( I th x faktor korekcije ), ovisno o broju ugrađenih aparata ( vidi Tabelu 1 ) In case of mounting of the fuse-switch disconnector in cabinet, the thermal current should be correcting ( Ith x derating factor ), depending on number of built apparatuses ( see Table 1 ) **U slučaju korištenja osigurač-rastavne sklopke na temparaturama +C do + C, termička struja I th treba biti smanjena za ( - 10 )% In case of using the fuse-switch disconnector at temperatures +C to + C, the thermal current Ith should be reduced for ( - 10 )% Tabela 1 / Table 1 Broj ugrađenih aparata / Number of built apparatuses Faktor korekcije / Correction factor ,9 0,8 0, >9 0,

6 TEHNIČKI PDCI / TECHNICL DT S-00/1 Tip / Type Nazivna termička struja na otvorenom Conventional free air thermal current Nazivni napon izolacije Rated insulation voltage Nazivni podnosivi udarni napon Rated withstand impulse voltage Nazivna frekvencija Rated frequency Kategorija upotrebe Utilization category Nazivna pogonska struja Rated operational ( making and breaking ) current Nazivni pogonski napon Rated operational ( making and breaking ) voltage ( siguračem ) uvjetovana kratkospojna struja Rated conditional short-circuit current Mehanička trajnost ( radni ciklusi ) Mechanical durability ( operating cycles ) Električka trajnost ( radni ciklusi ) Electrical durability ( operating cycles ) Gubici (bez uložaka osigurača) Power dissipation (without fuse-links) Stupanj zaštite ( poklopac zatvoren ) Degree of protection ( cover closed ) Stupanj zaštite ( poklopac otvoren ) Degree of protection ( cover opened ) Stupanj zagađenja Pollution degree Dopuštena radna temperatura okoline Permissible ambient temperature ** Temperatura skladištenja Storage temperature Težina ( bez uložaka osigurača ) Weight ( without fuse-links ) Pakiranje Package S V C90 C90 kv 0 ( 0- ) 0 ( 0- ) Hz C-21B C-22B C-21B keff W 1 12 C90 C00 C00 C20 V C-22B , 10,2 IP20 IP20 IP10 IP10 C C kg kom pcs 0,28 0, 1 * U slučaju montaže osigurač-rastavne sklopke u ormar potrebno je korigirati termičku struju ( I th x faktor korekcije ), ovisno o broju ugrađenih aparata ( vidi Tabelu 1 ) In case of mounting of the fuse-switch disconnector in cabinet, the thermal current should be correcting ( Ith x derating factor ), depending on number of built apparatuses ( see Table 1 ) **U slučaju korištenja osigurač-rastavne sklopke na temparaturama +C do + C, termička struja I th treba biti smanjena za ( - 10 )% In case of using the fuse-switch disconnector at temperatures +C to + C, the thermal current Ith should be reduced for ( - 10 )% Tabela 1 / Table 1 Broj ugrađenih aparata / Number of built apparatuses Faktor korekcije / Correction factor ,9 0,8 0, >9 0, MJERNE SKICE / DIMENSIN DRWINGS S-00C/S 1, ,9 9 18, 12 mm 1 mm 20 mm 0 mm 2 mm max 2, / 2, montirano / nemontirano installed / not installed Dimenzije u mm Dimensions in mm

7 MJERNE SKICE / DIMENSIN DRWINGS S-00C/1 8 8, Mjere za montažu Mounting dimensions 9, 1 9, 2 * 18 S-00C/2 8,,, , * 18 S-00C , 2 1 9, 9, 0 8 * 18 S-00C/ 8, 9, 8 * Dimenzije u mm Dimensions in mm *Sa priborom za pričvršćenje na profilni nosač mm *With accessories for snapping onto mm mounting-rail Φ Φ Φ , 2 Φ 12

8 MJERNE SKICE / DIMENSIN DRWINGS S-00/ * 19 9, S-00/ * , S * 19 2 R., 2 18 S-00/ , 2 11* 19 R Dimenzije u mm! *Sa priborom za montažu na sustav šina ( 12 mm, 10 mm) - NISKNPNSKE SKLPKE I PREKIDČI d.o.o. Borongajska cesta 81b HR Zagreb, Croatia p.p (0) , Tel : +8 (0)1 20 Fax : prodaja@koncar-nsp.hr +8 (0)1 29 2, 29 2 Tel : +8 (0) Fax : export@koncar-nsp.hr 28, 2

REDNE STEZALJKE LINE - UP TERMINALS

REDNE STEZALJKE LINE - UP TERMINALS REDNE STEZALJKE LINE - UP TERMINALS ISO 9001 Q-051 ISO 14001 E-063 D07 / 0.05. Pregled izvedbi Summary of available types M3;4 BSK VL StB PS VH QL TW AD M3;4 VH KD AP OZN TS-35 RSU,5 RSU 4 RSU,5 0Z6501

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH00 is intended fuse-links with blade contacts size 000 and 00. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

DML POTOPNE PUMPE ZA FEKALNE KANALIZACIJSKE OTPADNE VODE

DML POTOPNE PUMPE ZA FEKALNE KANALIZACIJSKE OTPADNE VODE APLIKACIJE Prepumpavanje civilnih i industrijskih fekalnih otpadnih voda Prepumpavanje kanalizacije iz septičkih jama Generalno prepumpavanje nečiste vode koja sadrži krute tvari Pražnjenje procjedne vode

More information

SF6 PREKIDAČI za kv SF6 CIRCUIT-BREAKERS for kv. tel: , fax:

SF6 PREKIDAČI za kv SF6 CIRCUIT-BREAKERS for kv. tel: , fax: Design&print: STUDIO HRG, Zagreb Photo: STUDIO HRG and KON^R High Voltage Switchgear - 690 001 R2 / 04.2010. ELEKTRIČNI VISOKONPONSKI PRTI HIGH VOLTGE SWITCHGER ELEKTRIČNI VISOKONPONSKI PRTI d.d. HIGH

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY

More information

switch disconnectors switch disconnectors fuses

switch disconnectors switch disconnectors fuses SWITCHGER R switch disconnectors RB switch disconnectors fuses R switch disconnectors and RB switch disconnectors fuses are designed for distribution of electricity, making and breaking currents and protection

More information

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom

More information

FUSE BASES NH FUSE BASES 690V 160A 160A

FUSE BASES NH FUSE BASES 690V 160A 160A fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00 2 4a Fuse-link

More information

MULTIVERT 1000A Main Incomer, 690VAC

MULTIVERT 1000A Main Incomer, 690VAC IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4 Busbar support 20 30 BBS-/1 BBS-/3 57 52 29 29 1 5 3 0 1 5 10 2 0 5 3 7, 5 6 0 6 0 6 0 6, 8 12 1 0, 5 7 5 1 2 5 2 4 0 20 30 18 BBS-/4 563 98,5 10 29 93,5 5 29 18 75 180 10,5 6,8 30 30 25 20 52,5 12 BBS-/3-16

More information

Motorized switch-disconnectors OTM 40 to 125 Amperes

Motorized switch-disconnectors OTM 40 to 125 Amperes Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 2.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 2.ST8 comprises NH fuse switch disconnectors for 400A. They are designed for bottom

More information

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K Varius SUMMARY OF MODELS OF FUSE-RAILS Type FSR00 FSR1 FSR2 FSR3 Rated operating current I e 160 A 250 A 400 A 630 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V Size 00 1 2 3 Busbar spacing

More information

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom

More information

Vertical fuse disconnects

Vertical fuse disconnects THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Vertical fuse disconnects

Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric circuits under

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS Varius SUMMARY OF MODELS Type FH00 FH1 FH2 FH3 LTL4a Rated operating current I e 160 A 160 A 250 A 400 A 630 A 1 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00

More information

VACUUM CIRCUIT BREAKERS VAKUUMSKI PREKIDAČI. Series VKΣ WITH POLES IN EPOXY RESIN TUBES S POLOVIMA U KRUTOJ IZOLACIJI. Slika 1 Fig.

VACUUM CIRCUIT BREAKERS VAKUUMSKI PREKIDAČI. Series VKΣ WITH POLES IN EPOXY RESIN TUBES S POLOVIMA U KRUTOJ IZOLACIJI. Slika 1 Fig. KONČAR - APARATI I POSTROJENJA d.d. KONČAR - SWITCHGEAR Inc. VAKUUMSKI PREKIDAČI Serije VKΣ S POLOVIMA U KRUTOJ IZOLACIJI VACUUM CIRCUIT BREAKERS Series VKΣ WITH POLES IN EPOXY RESIN TUBES Slika 1 Fig.

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

IP20 degree of protection; IP40 degree of protection after installation in a distribution box RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance

More information

Manual motor starter magnetic only MO325

Manual motor starter magnetic only MO325 Data sheet Manual motor starter magnetic only MO325 Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF

More information

MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s

MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s Basic Efficiency up to 1500 V 1-pole 3-pole SILAS MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN successfully

More information

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole MULTIBLOC 000.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS The production programme of MULTIBLOC 000.ST8 comprises NH fuse switch disconnectors for 100A. They are designed

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Thermostats Filters and Fans Terminals Electrical Cabinet Heating Catalogue 2016 Fuse Switch Disconnectors XNH Fuse

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC FUSE RAILS IEC NH FUSE RAILS FEATURES & BENEFITS Installation on to Dimensions of s and cable connections are equivalent to those of MULTIVERT APPLICATIONS

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector Product brochure ABB Fusegear EasyLine Fuse switch disconnector 2 EasyLine Fuse Switch Disconnector ABB Fusegear Content Fuse protection 4 Technical Data 5 General 6 Apparatus overview 7 Electronic Fuse

More information

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33 BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

K50F003UP cam changeover switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting Characteristics cam changeover switch - 3-pole - 60-50 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

K63F003UP cam changeover switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting Characteristics cam changeover switch - 3-pole - 60-63 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 11 18 19 02 04 05 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fibber glass rod gasket sphere sphere 51 52 5 56 41 42 adjustable lever

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

LV HRC fuse switch-disconnectors

LV HRC fuse switch-disconnectors The 9 series LV HRC fuse switch-disconnectors of the DIN sizes 00-4a are suitable for surface mounting on mounting plates and for direct mounting on busbars. The different sizes are available as 1-pole,

More information

Vertical fuse disconnects

Vertical fuse disconnects THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fusecarriers enable opening and closing operation in electric

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

Horizontal fuse disconnects

Horizontal fuse disconnects THE NAME FOR SAFETY Horizontal fuse disconnects Horizontal fuse disconnects Horizontal fuse Disconnects are used in building installations, switchgear and controlgear as well as in power utility networks.

More information

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics LC1F400E7 Complementary [Uimp] rated impulse withstand voltage Overvoltage category [Ith] conventional free air thermal current Main Range Product name Product or component

More information

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems The Complete Range Easy mounting onto supporting rails Protection against accidental contact in the standart version Perforated versions for connections Drawing of the NH Fuse-Switch, 3-pole switching,

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Strip type fuse-switch-disconnectors

Strip type fuse-switch-disconnectors Strip type fuse-switch-disconnectors NV Strip type fuse-switch-disconnector sizes 00, 1, 2, Characteristics of the NV Strip type fuse-switch-disconnectors The NV Strip type fuse-switch-disconnectors are

More information

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand LV-SWITCHING DEVICES / NH-SCHALTGERÄTE 1 Vertical 415 design fuse rails TRIVER / NH-Sicherungsleisten TRIVER Range / Produktpalette Type 415 fuse rails BTVA/BTVA-P, NH 1/2/3, 2/400/, mm busbars spacing

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

MEDIUM VOLTAGE DISCONNECTOR SWITCHES for indoor installation

MEDIUM VOLTAGE DISCONNECTOR SWITCHES for indoor installation KON^AR KONCAR MEDIUM VOLTAGE APPARATUS, Inc. MEDIUM VOLTAGE DISCONNECTOR SWITCHES for indoor installation Series RSN General Information Disconnector switches are part of traditional medium voltage assortment.

More information

Switches disconnectors with fuse-holders. XNF series TF series

Switches disconnectors with fuse-holders. XNF series TF series Switches disconnectors with fuse-holders XNF series TF series Quick Reference Switch-disconnectors with fuse-holders XNF series TF series XNF Series page 155 16 32A with fuse holders 3 4 Pole Auxiliary

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

Changeover & Bypass Sw it ches

Changeover & Bypass Sw it ches Changeover & Bypass Switches St ate of the art Manufacturing Facilit ies Haridw ar, Noida Ph-I & Noida Ph-II Plant Changeover & Bypass Sw it ches Introduction On Load Changeover Switches (with & without

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Characteristics SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Product availability : Stock - Normally stocked in distribution facility Price* : 68.00 USD Main Range of product Product or component type Device

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

KATA LOG 2015 PUMPE 2 18

KATA LOG 2015 PUMPE 2 18 PUMPE 2 18 Speck Magic Blok pumpa s integriranim predfilterom. Klizni brtveni prsten montiran na plastičnu lopaticu. Osovina motora zaštićena od dodira sa bazenskom vodom. Volumen predfiltera : oko 0,5

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC Product data sheet Characteristics LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Trifazni kondenzatorji KNK

Trifazni kondenzatorji KNK Trifazni kondenzatorji KNK Features Vezava profile Φ 90 and 116 mm 2-16 mm 2, Φ 136 mm 2-25 mm 2 *Use of flexible conductors only with ferrules Capacitors equipped with discharge resistors Nazivna moč

More information

T-Switches Range. TL Contactors TS disconnectors TP Contactors. TELARC s multipurpose DC and AC current switches for multiple application.

T-Switches Range. TL Contactors TS disconnectors TP Contactors. TELARC s multipurpose DC and AC current switches for multiple application. TP-PNORM T-Switches Range TL Contactors TS disconnectors TP Contactors TELRC s multipurpose DC and C current switches for multiple application Rolling Stock Energy generation Substation equipment Industrial

More information

MULTIVERT 250A Size 1, 690VAC

MULTIVERT 250A Size 1, 690VAC MULTIVERT 250A IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors.

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products 94 D 5384 Technical Brochure Rotary Type nstallation Switches 16...160 A, 500 V Brochure T_M 22 GB 99-08 Low Voltage Products 9809CD03 Rotary Type nstallation Switches 16 A...160 A ew features for installation

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

Safety switches for hinges

Safety switches for hinges Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded

More information

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

CATALOG. EasyLine XLP Fuse Switch Disconnector poles CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX 70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency

More information

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC Product datasheet Characteristics LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

ABB STOTZ-KONTAKT GmbH

ABB STOTZ-KONTAKT GmbH ABB STOTZ-KONTAKT GmbH MULTIPLE 89 Motijheel C/A, Lucky Chamber (3rd floor, Room #61), Dhaka-1000, Bangladesh. Tel: (02) 9559692, Fax: (02)9566596 E-mail: info@multipletrading.net PAGE : 02 The ABB Line

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information