Minimum Cavity Guns. Technical Manual. Part A NORDSON CORPORATION AMHERST, OHIO USA

Size: px
Start display at page:

Download "Minimum Cavity Guns. Technical Manual. Part A NORDSON CORPORATION AMHERST, OHIO USA"

Transcription

1 Minimum Cavity Guns Technical Manual Part A NORDSON CORPORATION AMHERST, OHIO USA

2 Nordson Corporation welcomes requests for Information, comments and inquiries about its products. Address all correspondence to Nordson Corporation 475 Lakefield Drive Duluth, GA 3036 Notice This is a Nord son Corporation publication which is protected by copyright. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Nordson Corporation. The information contained in this publication is subject to change without notice. Trademarks AquaGuard, Blue Box, Control Coat, Equi~Bead, FloMelt, FoamMelt, FoamMix, Helix, Hot Shot, Hot Stitch, Meltex, MicroSet, MultiScan, Nordson, the Nordson logo, OmniScan, Porous Coat, Posi-Stop, RBX, Sure-Bond, UniScan, UpTime, and Versa-Spray are registered trademar<.s of Nordson Corporation. BetterBookSM, CF, Controlled Fiberization, Easy Screen, Fibermell, Flo-Tracker, PrintGuard, and Package of Values are trademar<.s of Nordson Corporation. Manual A Issued 389 o 989 NO<dson CO<po<aloo All A'IJhls Reserved

3 Minimum Cavity Gun Manuai4 3B Page 0 Table of Contents SECTION SAFETY SUMMARY Explanation Of Terms And Symbols... - Safe ty During Installation Electrical... - Pneumatic... - Safety During Operation... - Safety During Servicing Safety When Using Hot Melt Adhesives And Solvents Hot Melt Adhesives Heating Solvents SECTION EQUIPMENT FAMILIARIZATION Introduction Functiona l Description... - SECTION 3 SPECIFICATIONS Spec ification Sumnary SECTION 4 DISASSEMBLY AND REPAIR RTD Replace ment Wiring Diagrams Pub. No A NORDSON CORPORATION 989 Issued 389

4 Manual4-38 Page 0- Minimum Cavity Gun SECTION 5 ILLUSTRATED PARTS LIST How To Use The Il lustrated Parts Lists Parts List for H0 I MCT Gun S- Parts List for H0 MCTLP and H0MCTLPW Guns... S-4 Parts List for H04 MCTLP and H04MCTLPW Guus Part s List for H08MCTLP Gun X Parts Lisr for Minimum Cav ity Modu le I 0 RL'commended Spare Parts List (H00MCT Guns) Issued 3/89 NORDSON CORPORATION 989 Pub. No A

5 Minimum Cavity Gun Manual 4 38 Page - SECTION! SAFETY SUMMARY INTRODUCTION Here you will find safety guidelines for the use of Nordson<E' equipment. These guidelines apply to anyone working with Nordson equipment, including operations and service personnel. They arc repeated throughout this manual, along with specific warnings and cautions not included in this section. These safety guidelines cover: Installation Equipment operation Working with hot melt materials Use of hot melt solvents NOTE: Failure to follow these recommendations may result in personal injury from burns or electrocution and/or equipment and property damage. EXPLANATION OF TERMS AND SYMBOLS The following safety symbols and signal words are used throughout this publication to alert the reader to personal safety hazards, or to identify conditions that may result in equipment or property damage. A WARNING: General Warning. Failure to observe may result in personal injury or death. Ji\. WARNING: Risk of electrical shock. Failure to ob ~ serve may result in personal injury or death. A CAUTION: General Caution. Failure to observe may result in minor personal injury or damage to property. NOTE: Important information. Failure to observe may result in equipment damage. Pub. No A NORDSON CORPORATION 989 Issued 3/89

6 Manual 4 38 Page - Minmurn Cavity Gun SAFETY DURING INSTALLATION Electrical. A protective electrical ground connection to a reliable earth ground is essential for safe operation. Without one, all accessible conductive components (including knobs and controls that appear insulated) can render an electric shock.. A disconnect switch with lockout capability must be provided hetween the power source a nd the equipment. 3. The power supply wire gauge and insulation must be sufficient to meet the temperature and power requirements. Pneumatic 4. Only fuses of th e correct type, voltage rating and current rating should be u sed. Refer to the Nordson equipment parts list for fuse recommendations. Using incorrect or nonrecommended fuses can present a fire hazard. Nordson recommends installing a lockout, t hree-way, manual valve in the air supply line to the filter/regulator. This valve makes it possible to relieve air pressure and lock out th e pneumatic system before undertaking maintenance or repairs. SAFETY DURING OPERATION DO NOT operate Nordson equipment under the following conditions:. At a pressure h igher than the rated maximum working pressure of any component in the system.. Near volatile or otherwise explosive gases or materials. 3. Without the covers, panels and safety guards properly installed. 4. At atmospheric temperatures below 0" F (-6 C) or above 0" F (50' C). 5. With hoses enclosed in any material that interferes with heat dissipation. This includes electrical conduit, insulation of a ny type or tight metal covers. Issued 3'89 CcJNORDSON CORPORATION 989 All Rghts Reserved Pub. No A

7 Minimum Cavity Gun Manua4 38 Page 3 6. With large areas of hose in contact with a cold floor, cold supports or other such surfaces. Cold points along the hose restrict the flow of adhesive inside the hose and can create potential problems during operation. 7. In drafty areas with the applicator guns unshielded from the draft. Rapid heat dissipation due to air movement across the guns may cause operational problems. in addition: SAFETY DURING SERVICING. Use only the metal base when attempting to lift or move an applicator. DO NOT use equipment covers, doors, panels or h ose connectors as braces or grips.. NEVER use Nordson equipment as a ladder or stepping stool. 3. Route all hoses so as to prevent damage from kinking, abrasion and other physical damage. DO NOT allow a hose to be installed with a bend radius ofless than 6 inches (50mm). 4. NEVER point an applicator handgun at yourself or anyone else.. DO NOT perform internal service or adjustment on any equipment unless another person capable of rendering first aid and resuscitation is present.. Only qualified personnel should service Nordson equipment. 3. To avoid personal injury, never touch exposed connections and components while power is ON. Dangerous voltages exist at several points in the equipment. 4. Disconnect, lock out and tag external electrical power before removing protective panels or replacing electrical components. 5. Remove all jewelry (rings, watches, etc.) before servicing equipment. 6. If possible, stand on a rubber mat when servicing Nordson equipment. DO NOT work on equipment if standing water is present. Avoid working in a high-humidity atmosphere. Cover exposed terminals and work areas with rubber sheeting to avoid accidental contact while the power is ON. Pub. No A NORDSON CORPORATION 989 Issued 389

8 Manual 4 38 Page 4 Minimum Cavity Gun 7. Always wear safety glasses, protective gloves (Nordson PIN or equivalent) and long-sleeved protective clothing to prevent injury from hot applicator parts, splashed hot melt adhesive and hot gun surfaces. 8. To prevent serious injury from molten adhesive under pressure, always relieve system hydraulic pressure (by triggering the gun. for example) before opening any hydraulic fitting or connection. 9. NEVER use an open torch, drill or broach when cleaning a nozzle. 0. NEVER operate equipment with a known leak in the system. SAFETY WHEN USING HOT MELT ADHESIVES AND SOLVENTS Hot Melt Adhesives. Use extreme care when working with molten materials. The molten materials solidify rapidly at high temperatures and present a hazard. Severe burns can occur if the molten materials come in contact with the skin. Even when first solidified, they are still hot.. Always wear protective clothing and eye protection when handling molten material or working near equipment containing hot melt adhesives under pressure. 3. IF MOLTEN MATERIAL COMES IN CONTACT WITH THE SKIN: DO NOT try to remove molten material from the skin. Immediately immerse the affected area in cold, clean water. Keep the affected areas immersed until the material has cooled. DO NOT try to remove the cooled material from the skin. Cover the affected area with a clean, wet compress. In cases of severe burns, look for signs of shock. If shock is suspected, have patient lie down, use a blanket to preserve body heat and elevate the feet several inches. Call a physician immediately. Issued 3i89 C?JNORDSON CORPORATION 989 Pub. No A

9 Minimum Cavity Gun Manual 4 36 Page 5 Heating Solvents. DO NOT use an open fl ame or uncontrolled heating device to heat solvents (for example, a small pa n on an unregulate-d h ot plate).. Avoid fire hazard by using a controlled heating device to heat solvents (for example, a small deep fat fryer or thermostatically controlled hot plate). 3. DO NOT USE PAINT-TYPE SOLVENTS UNDER ANY CIR CUMSTANCES! These solvents are volatile and may be a fire and/or toxic-vapor hazard even at room temperature. 4. Always be sure the work area is adequately ventilated. Avoid prolonged or repeated breathing of solvent vapors. 5. Halogenated Hydrocarbon Solvents are dangerous when used to clean aluminum components in a pressurized fluid system. No available stabilizers prevent halogenated hydrocarbon solvents from reacting under all conditions with aluminum components in a pressurized fluid pumping system. 6. NEVER clean any aluminum component or flush any system using halogenated hydrocarbon solvents. Use TypeR (PIN ) solvents or contact your solvent or hot melt supplier for a non-halogenated hydrocarbon solvent for cleaning and flushing. Halogenated fluids include the following solvents: Fluorinated Solvents: Dichlorofluoromethane Trichlorofluoromethane Chlorinated Solvents: Carbon Tetrachloride Chloroform Dichloromethane Ethlylene Dichloride Methylene Chloride Monochlorobenzene Monchlorotoluene Pub. No A NORDSON CORPORATION 989 Issued 389

10 Manual 4-38 Page 6 Minimum Cavity Gun Orthodichlorobenzene Perchloroethylene Trichloroethylene Brominated Solvents: Ethylene Dibromide Methyl Bromide Methylene Chlorobromide Iodinated Solvents: Ethyl Iodide Methyl Iodide N-butyl Iodide Propyl Iodide ~ORDSON CORPORATION 989 All Rghts Reserved Pub. No A

11 Minimum Cavity Gun Manual 4 38 Page - SECTION EQUIPMENT FAMILIARIZATION INTRODUCTION FUNCTIONAL DESCRIPTION The minimum cavity guns are special H00 series guns designed for applications ~here precise bead disposition is required, and/or where FoamMelt equipment is used. Like all H00 guns, they are compact, automatically fired, and equipped with a spring adjustment that permits the synchronization of gun firing and cutoff. These guns differ from other H00 guns, however, in that there is a reduced cavity between the seat and the nozzle orifice. This feature minimizes the formation of pockets of material inside the nozzle and reduces drooling of foamed hot melt material caused by expansion in this area. Minimum cavity guns can be purchased in a variety of configurations. The threaded seat accepts a series of nozzles which are designed with a minimum cavity. The H00MC gun receives molten hot melt adhesive, foamed adhesive, or other thermoplastic material from an applicator connected to the gun by one or two hoses. When non-foamed materials are used, a single hose is connected directly to the service block. When foamed materials are used, a gun installation kit Pub. No. 07 9SSA ~ORDSON CORPORATION 989 Issued 389

12 Manual 4-38 Page - Minimum Cavity Gun is required to allow for the connection of a second hose for circulation external to the gun. (See table below for correct Part Numbers) The material enters the gun module through the service block, which contains an inlet port for the adhesive, a port for pressurized air, a heater cartridge, and an RTD to maintain gun temperature. The gun is activated when an electrically-controlled solenoid valve receives a signal from a triggering device ( a microswitch, photocell, etc.). Air pressure forces the piston in the gun module upward, lifting the attached needle off its seat. Adhesive flows from the nozzle until the triggering device de-energizes the solenoid valve. When the valve is de-energized, the air under the piston is vented through the solenoid valve. As the air is exhausted, the piston return spring forces the needle against the seat, stopping the flow of adhesive. Table Gun Installation Kits for Foam Materials Standard Multi Modules P/N Single or Low Profile Modules Auto Biaxial Hose Standard Hose P!N " PIN " PIN " P/N " P/N Straight P!N Straight Issued 389 NOROSON CORPORATION 989 Pub. No A

13 Minimum Cavity Gun Manual 4-38 Page 3- SECTION3 SPECIFICATIONS SPECIFICATION SUMMARY* Working hydraulic pressure, maximum Supply air pressure Operating air pressure Air consumption per module, at 3000 cpm at 30 psi operating pressure Operating temperature, maximum Gun heating method Electrical requirements Dimensional data 500 psig (0.3 MPa) 60 to 00 psig (0.6 to 0.69 mpa) 30 to 00 psig (0. to 0.69 mpa) 6.7 SCFH 450"F (30.C) Cartridge heater controlled by Resistance Temperature Detector (RTD) 30 VAC, 50/60 Hz. See Figure 3-, 3- *Due to possible technological and/or quality improvements, equipment specifications a re subject to change without notice. Pub. No A NORDSON CORPORATION 989 Issued 3/89

14 Manual4-38 Page 3 - Minimum Cavity Gun.58 (40.4) 4.85 (3.) I.5.& (4.7 I :: (.7) _,.. J (4.) Figure 3-- Dimensions for the H0MC Guns 4.83 (.7) 6.80 (75.3) I I -.00 (5.4) Figure 3-- Dimensions for Two and Four Module Low Profile Minimum Cavity Guns Issued 3'89 NORDSON CORPORATION 989 Pub. No 07 95'iA

15 Minimum Cavity Gun Manual 4 38 Page 4 SECTION4 DISASSEMBLY AND REPAIR RTD Replacement See the H00 Series Gun manual (4-8) for operating instructions, maintenance and troubleshooting procedures. This section includes instructions for the replacement of the service body RTD and the wiring diagrams for the H00MC guns. Refer to the appropriate figure in Section 5, Illustrated Parts List, for physical location of components. Use the RTD Replacement Kit (PIN ) to replace a defective RTD in the H00MC gun service body module.. Disconnect the electrical connection between the gun and the hose and disconnect and lock out the input electrical power to the applicator. A WARNING: Nordson H00MC guns contain energized electrical components with potentials that could be fatal. Disconnect and lock out input electrical power to the gun before attempting any repair or replacement.. Remove the screws that secure the cover to the service body module. 3. Remove the cylindrical RTD from its mounting hole in the service body module. 4. Cut the two R'l'D lead wires approximately inch from the defective RTD and discard the RTD. 5. Strip about 4 inch of insulation from the cut wires. 6. Using parts supplied in the RTD Replacement Kit, twist the leads of the new RTD together with the cut wires and secure them with the two wire nuts. NOTE: It does not matter which lead is connected to which wire because the RTD is not polarity sensitive. Pub. No A NORDSON CORPORATION 989 Issued 3/89

16 Manua4-38 Page 4- Minimum Cavity Gun 7. Slide the RTD into its mounting hole in the service body. 8. Replace the service body cover and cover screws. 9. Reconnect the hose to the gun electrically and restore the input power. The system is ready for operation. Figure 4- - Wiring Diagrams for H0MC Guns Issued CORPORATION 989 All Righls Reserved Pub. No A

17 Minimum Cavity Gun Manual 4-38 Page 4-3 H E A T E R H E A T E R Figure 4- - Wiring Diagram for H0MC and H04MC Guns Pub. No A NORDSON CORPORATION 989 Issued 3/89

18 Manual 4-38 Page 4-4 Minimum Cavity Gun R T E R H H E t: A A T T E E R R Figure 4-3- Wiring Diagrams for H08MC Guns Issued CORPORATION 989 Pub. No A

19 Minimum Cavity Gun Manual 4 38 Page 5 SECTIONS ILLUSTRATED PARTS LIST HOW TO USE THE ILLUSTRATED PARTS LISTS. Refer to the appropriate page and use the component illustration for part(s) identification. Note the item number call-out for the part.. Locate the item number in the Item Number column. 3. The next three columns give the Part Number, Description, andrequired (Req'd) quantity of the item in the assembly. a. The Part Number column contains either the six digit part number or a dash (-). A dash in the column means that the part is a non-saleable item, and cannot be ordered. It may be possible to obtain the part if it is a subassembly ( ) of a saleable item. b. The Description column contains "bullets" ( ) which indicate the assembly level of the part. A part whose description is preceded by a single bullet ( ) is a subassembly of the component above it without a bullet. A part whose description is preceded by two bullets ( ) is a subassembly of the component above it with a single bullet ( ). c. The Required (Req'd) column contains the quantity of the part within the illustration. "Ref' indicates that the part is listed for reference purposes only. A dash(-) indicates that the item is utilized only as necessary within the component. Pub No A NORDSON CORPORATION 989 Issued 3/89

20 Manual 4-38 Page 5- Minimum Cavity Gun P arts List for H0MCT Gu n Item No. Par t No. Description Req'd Gun, H0MCT Ref Body, Manifold Single Module Not Used Heater, 40V, 50W,.375 Dia,.8 Module. Minimum Cavity (See Figure 5-5) Paste Insulator, Single Module Kit, Retainer, Single Module Screw, Pan Hd, #0-3 x.50 Screw, Hex Hd, 5/6-8 x Washer, Flat Strap, Cable, Tag, Set, Guns Not Used Not Used Not Used Washer, Lock, Split, #5 Screw, Fil Hd, #5-40 x.50 Not Used Nut, Panel Mounting Washer, Lock, E, Ext,.375 Cover, Single Module Std, Black Cordset Assembly, 300 Screw, Pan Hd, #8-3 x.50 Connector Assembly, Gun Screw, Drive, x.87 Plate Information Connector, Porcelain Never Seez, 6 oz. Aerosol can Installation Kit (Not Shown) 4 Issued 3/89 NORDSON CORPORATION 989 Pub. No A

21 Minimum Cavity Gun Manual 4 38 Page 5 3 \\ I,; ji QJ -a '"0 0 ~ QJ bo... c:: U) $ "> C<S (.) e ;:l e... c:: ~ ~ 0 ~ ::r: ~ I lo QJ,... So ~ ~ tml :Et!.. u ::> Q 0 : 0! :m.... g ~ u d.. ~.. 0 : 0 : ::> % ~ " w Q ~ Q 0:.. Pub. No A ( :t.j0rdson CORPORATION 989 Issued 3/89

22 Manual 4-38 Page 5-4 Minimum Cavity Gun Parts List for H0MCTLP and H0MCTLPW Guns* Item Part No. No. Description Gun, H0MC Gun, H0MC, Water Resistant 9877 Screw, Fil Hd, #8-3 x.500 Cover, H0TLP Gasket, Cover Connector, Porcelain Screw, Fil Hd, #5-40 x.50 6 Body, H00, Module Plug, Pipe, / Cordset, Water Resistant, H0MCTLPW Cordset Assembly, H0MCTLP Paste Connector Assembly, Hose, 45 Deg Heater, 40V, loow,.5 Dia. x Nut, Hex, Reg, Screw, Hex Hd, /4-0 x 5/ Bracket, Mounting, Weldment Insulator, Mtg, LP 6 Coating, Primer, Locquic Adhesive, Loctite Module, Minimum Cavity 9 Primer, Locquic Grade T Strap, Cable, Tag Set, Guns Washer, Lock, Split, # Gasket, Mtg, LP 5 Loctite Installation Kit Req'd Ref Ref 6 3 *Four module gun shown for reference only. Issued 3/89 NORDSON CORPORATION 989 All Rghts Reserved Pub. No A

23 Minimum Cavity Gun Manual 4-38 Page 5-5 &----~ I. INCLUDED WITH ITEM i [! il I I Figure 5- - H0MCTLP and H0MCTLPW Guns Pub. No. 07 9SSA NORDSON CORPORATION 989 Issued 389

24 Manual 4 38 Page 5 6 Minimum Cavity Gun Parts List for H04MCTLP and H04MCTLPW Guns Item No. P art No. Descrip t ion Req'd Gun, H04MC Gun, H04MC, Water Resistant Ref Ref Screw, F'il Hd, #8-3 x.500 Cover, H04TLP Gasket, Cover Connector, Porcelain Screw, Fil Hd, #5-40 x.50 Body, H04 Plug, Pipe, /6 Cordset, Water Resistant, H04MCTLPW Cordset Assembly, H04MCTLP Paste, Connector Assembly, Hose, 45 Deg. Heater, 40V, 55W,.37 Dia. x.50 Nut, Hex, Reg,.50-3 Screw, Hex Hd, /4-0 x 5/8 Bracket, Mounting, Weldment Insulator, Mtg, LP Coating, Primer, Locquic Adhesive, Loctite Module, Minimum Cavity Primer, Locquic Grade T Strap, Cable, Tag Set, Guns Washer, Lock, Split, #5 Gasket, Mtg, LP Loctite 7 Installation Kit Issued 3/89 NORDSON CORPORATION 989 Pub. No. 07 9SSA

25 Minimum Cavity Gun Manual4 38 Page 5 7 cv-----n I. INCLUDED WITH ITEM 8 Figure 5-3- H04MCTLP and H04MCTLPW Guns Pub. No A ~CROSON CORPORATION 989 Issued 3/89

26 Manual4-38 Page 5-8 Minimum Cavity Gun Parts List for H08MCTLP Gun Item No. Part No. Description Reg'd Gun, H08MCTLP Ref Cover, Gun Screw, Pan Hd, #0-3 x.375 Cordset Assembly Washer, Lock,.375 Nut, Panel Mounting Plug, Button, 3/8 Dia. Plug, Pipe, 6 Coating, Primer, Locquic Adhesive, Loctite Heater, 40V, 0W,.38 Dia. x.75 Module, Minimum Cavity Paste Body, Manifold, 8 Module Connector Assembly, Gun Tag Set, Guns Strap, Cable, Nut, Hex, Reg,.50-3 Insulator Bracket, Mounting Screw, Skt Hd, 4-0 x 5/8 Washer, Lock, Split, #5 Screw, Fil Hd, #5-40 x.50 Not Used Nameplate Rivet, Pop, 3/3 x.40 Never Seez, 6 oz. Aerosol Can Installation Kit Issued 3/89 NORDSON CORPORATION 989 Pub. No A

27 Minimum Cavity Gun Manuai4 3S Page 5 9 '. I r /<// -:;:; ~ I! V. I \ F " tgure H08 MCTLP Gun Pub. No SA NORDSONCORP~~~~~ AII Rights R ORATION 989 eserved --;--- ~ Issued 3/89

28 Manual 4-38 Page 5-0 Minimum Cavity Gun Parts List for Minimum Cavity Module Item No. Part No. Description Reqd Minimum Cavity Module Ref Screw, Loading Nut, Locking, -8 Cap, Air, Adj. Spring, Comp,.46 x.36 x.065 Paste Washer, Seal, Piston Lubricant, Silicone Screw, 6-3 x 5/8 0-Ring, Viton,.33 x.438 x.063 Spring, Comp,.805 x.300 x.065 Retainer, Spring Adhesive, Loctite #60 Screw, Soc Set, 4-40 x.375 Nut, Zero Cavity Needle Washer, Piston Body, Module Washer, Backup Nozzle, Assembly, w/needle ( See Tables on Page 5- for available Nozzle Assemblies) Seat, Nozzle Guide, Needle 0-Ring, Viton,.375 x.500 x.063 Needle, Zero Cavity Screw, Soc Hd, Cap, 0-3 x /4 Screw, Fil Hd, #8-3 x.375 Ring, Retain,.438, Pushon Disk, Seal Support Seal, Hat, Formed 4 3 Issued 3!89 NORDSON CORPORATION 989 Pub. No A

29 Minimum Cavity Gun Manual4 38 Page 5- & ~ 4 -~ ~! 0 I ---~ Figure 5-5- Minimum Cavity Module Pub. No. 07 CORPORATION 989 Issued 3/89

30 Manual 4-38 Page 5- Minimum Cavity Gun Two Orifice Nozzle Angle Orifice Diameter, Part No. de g. in. (mm) (.30) (.30) (.30) (.30) (.36) (.4) (.46) (.5) Three Orifice Nozzle Angle Orifice Diameter, Part No. de g. in. (mm) (.30) (.30) (.4) (.46) (.5) Four Orifice Nozzle Angle Orifice Diameter, Part No. A B in. (mm) (.30).04 (.36).06 (.4).08 (.46).00 (.5) Part No go Single Orifice Nozzle Orifice Diameter, inch Issued 3/89 NORDSON CORPORATION 989 Pub. No A

31 Minimum Cavity Gun Manual 4-38 Page 5-3 Recommended Spare Parts List (H00MCT Guns) Part Number Description Req'd * 0-ring, Viton, 0.3 in. ID x 0.44 in. OD Screw, Socket Head, 0-3 x.5 in. Screw, Fil Hd, 6-3 x.5 in. Kit, RTD Replacement 0-ring, Viton, 0.38 in. Tube Module Cartridge, Heater *The cartridge heater required varies from gun to gun. See the parts list of the standard T gun in question for the part number of the heater Pub. No A NORDSON CORPORATION 989 Issued 389

32 Manual 4-38 Page 5-4 Minimum Cavity Gun This Page Intentionally Left Blank Issued 3/89 NORDSON CORPORATION 989 Pub. No A

Normally Open H200 and 90_ CF200 Module Seal Rebuild Kit

Normally Open H200 and 90_ CF200 Module Seal Rebuild Kit Instruction Sheet 108 792A Normally Open H200 and 90_ CF200 Module Seal Rebuild Kit 1. Description Use this rebuild kit to service the following modules: S Normally Open H200 (N.O. H200) Module -- P/N

More information

Nordson/Drexelbrook Material Level Control Kit

Nordson/Drexelbrook Material Level Control Kit Nordson/Drexelbrook Material Level Control Kit NORDSON CORPORATION. AMHERST, OHIO. USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

Hot Melt Guns. Part A NORDSON CORPORATION. AMHERST, OHIO. USA

Hot Melt Guns. Part A NORDSON CORPORATION. AMHERST, OHIO. USA Hot Melt Guns Part 14 448A NORDSON CORPORATION. AMHERST, OHIO. USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence to Nordson

More information

TWO COMPONENT SYSTEM METERING VALVE

TWO COMPONENT SYSTEM METERING VALVE TWO COMPONENT SYSTEM METERING VALVE Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

Auto-Flo Air-Assist Automatic Dispensing Valve

Auto-Flo Air-Assist Automatic Dispensing Valve Auto-Flo Air-Assist Automatic Dispensing Valve Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its

More information

Auto-Flo Panel Reinforcement Automatic Dispensing Valve

Auto-Flo Panel Reinforcement Automatic Dispensing Valve Auto-Flo Panel Reinforcement Automatic Dispensing Valve Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries

More information

Hot Melt Applicator. Model VII. Part C NORDSON CORPORATION. AMHERST, OHIO. USA

Hot Melt Applicator. Model VII. Part C NORDSON CORPORATION. AMHERST, OHIO. USA Hot Melt Applicator Model VII Part 04 385C NORDSON CORPORATION. AMHERST, OHIO. USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

SP30 6:1 Piston Pump. Installation and Maintenance Instructions. Part D NORDSON CORPORATION AMHERST, OHIO USA

SP30 6:1 Piston Pump. Installation and Maintenance Instructions. Part D NORDSON CORPORATION AMHERST, OHIO USA Installation and Maintenance Instructions Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

SP30 10:1 Piston Pump

SP30 10:1 Piston Pump Instruction Sheet P/N SP30 10:1 Piston Pump 1. Safety Read this section before using the equipment. This section contains recommendations and practices applicable to the safe installation, operation, and

More information

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet Instruction Sheet Replacing a Gun RTD WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation.

More information

Swivel I/O Manifold. 3. Operation After intallation, no further attention to the swivel manifold is required. Foam AG-900 Swivel I/O Manifold 1

Swivel I/O Manifold. 3. Operation After intallation, no further attention to the swivel manifold is required. Foam AG-900 Swivel I/O Manifold 1 Foam Mix@ AG-900 Swivel I/O Manifold Swivel I/O Manifold. Introduction The Nordson line of swivel manifolds adds considerable versatility to the FoamMix@ dispensing system in robotic applications Specifically,

More information

E-750 Electric Applicator Technical Manual

E-750 Electric Applicator Technical Manual E-750 Electric Applicator Technical Manual Part 104 834B NORDSON CORPORATION a AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address

More information

OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E

OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E Nordson Corporation OPERATOR S CARD P/N 32 96E Select Series H-400 Hot Melt Dispensing Guns Safety WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection

More information

MELTEX Electropneumatic Hot Melt Application Head EP 26 SD

MELTEX Electropneumatic Hot Melt Application Head EP 26 SD MELTEX Electropneumatic Hot Melt Application Head Manual P/N 409 097 A - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY NOTE This manual applies to the entire series. Order number P/N = Order number

More information

Series H-400 Guns. Customer Product Manual Part D. NORDSON CORPORATION D Duluth, Georgia

Series H-400 Guns. Customer Product Manual Part D. NORDSON CORPORATION D Duluth, Georgia eries H-400 Guns Customer Product Manual Part NORDON CORPORATION D Duluth, Georgia www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information, comments

More information

SECTIONS ILLUSTRATED PARTS LISTS

SECTIONS ILLUSTRATED PARTS LISTS AD-3 FM Swirl and Extrusion Handguns Manual 4-6 Page 8- SECTIONS ILLUSTRATED PARTS LISTS INTRODUCTION This section contains illustrations and parts lists for both the swirl and extrusion versions of the

More information

Rhino SD3/XD3 Air Motor

Rhino SD3/XD3 Air Motor Rhino SD3/XD3 Air Motor Customer Product Manual Issued 6/18 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson

More information

Section 8. Parts A Issued 7/00. Manual V -MA -01 (formerly 7-505/6V -MA -01) E 2000 Nordson Corporation All rights reserved

Section 8. Parts A Issued 7/00. Manual V -MA -01 (formerly 7-505/6V -MA -01) E 2000 Nordson Corporation All rights reserved Section 8 E 000 Nordson Corporation 00 497A Manual 47-506V -MA -0 (formerly 7-505/6V -MA -0) 8-0 Manual 47-506V -MA -0 (formerly 7-505/6V -MA -0) 00 497A E 000 Nordson Corporation 8- Section 8. Introduction

More information

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B Sure Coat Modular Gun Control System Part B: Pneumatic Modules Customer Product Manual Issued 4/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800)

More information

Series 3900/M Pump Retrofit Kit

Series 3900/M Pump Retrofit Kit Instruction Sheet P/N Series 900/M Pump Retrofit Kit WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related

More information

A CAUTION: The kit should not be fitted on Series 3800 or 3900

A CAUTION: The kit should not be fitted on Series 3800 or 3900 Series 3000 O:l Pump Installation Kit Instructions 6-52 Page O:l SINGLE ACTING PUMP INSTALLATION (P/N 3 598) KIT INTRODUCTION. The O:l Single Acting Pump Installation Kit gives you all the necessary items

More information

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B Sure Coat Modular Gun Control System Part D: Gun Purge Module Customer Product Manual Issued 4/0 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 4-919

More information

Manual Clear Primer Application System

Manual Clear Primer Application System Manual Clear Primer Application ystem Part 107002B NORDON CORPORATION D AMHERT, OHIO D UA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with an out-in filter. Table of Contents Filter...................................................... 10-1 Introduction................................................

More information

Installing the Integral Platen Blow Off Valve

Installing the Integral Platen Blow Off Valve Instruction Sheet Installing the Integral Platen Blow Off Valve WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all

More information

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01 Section 9 NOTE: This section applies to applicators with CC200 modules. 9-0 Table of Contents i Table of Contents Section 9 1. Introduction............................................... 9-1 2. Specifications.............................................

More information

Prodigy HDLV Pump. Customer Product Manual Part A02

Prodigy HDLV Pump. Customer Product Manual Part A02 Prodigy HDLV Pump Customer Product Manual Issued 1/07 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

Rhino SD3/XD3 5-Gallon Follower Modules

Rhino SD3/XD3 5-Gallon Follower Modules Rhino SD3/XD3 5-Gallon Follower Modules Customer Product Manual Part 6033 03 Issued 6/8 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with an in-out filter. Table of Contents Filter...................................................... 10-1 Introduction................................................

More information

Model C-1 Electrostatic Airless Spray Gun OBSOLETE. Customer Product Manual. Part D NORDSON CORPORATION AMHERST, OHIO USA

Model C-1 Electrostatic Airless Spray Gun OBSOLETE. Customer Product Manual. Part D NORDSON CORPORATION AMHERST, OHIO USA Model C-1 Electrostatic Airless Spray Gun Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products.

More information

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules.

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules. 9-1 Section 9 NOTE: This section applies to applicators with CF200PAD right-angle modules. Table of Contents.................................................... 9-1 Introduction................................................

More information

Pro-Swirl Manifold Air Heater

Pro-Swirl Manifold Air Heater Instruction Sheet P/N 16107 01 Description The Pro-Swirl manifold heats air coming from the Pro-Swirl coalescent filter. The heater air then flows through the internal passages of the Pro-Swirl to maintain

More information

Prodigy HDLV Generation II Pump Panel

Prodigy HDLV Generation II Pump Panel Prodigy HDLV Generation II Pump Panel Customer Product Manual Issued 01/10 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to change

More information

Parts. Part B, Section 5. Model 3500 Voltage 1, 2. Manifold 6-Port (B or C) 2-Port (S or T) Issued 11/00 B5EN-05-[3-PARTS]-6

Parts. Part B, Section 5. Model 3500 Voltage 1, 2. Manifold 6-Port (B or C) 2-Port (S or T) Issued 11/00 B5EN-05-[3-PARTS]-6 Part B, Section 5 Model 500 Voltage, Pump Piston (E) Manifold -Port (B or C) -Port (S or T) Control MultiScan (M) 000Nordson Corporation -000 Issued /00 B 5-0 -000 Issued /00 000 Nordson Corporation B

More information

Universal Automatic Non-Conductive Fluid Regulator

Universal Automatic Non-Conductive Fluid Regulator Universal Automatic Non-Conductive Fluid Regulator Customer Product Manual Part 1017527 04 Issued 3/18 NORDSON CORPORATION AMHERST, OHIO USA Table of Contents tents Safety... 1 Qualified Personnel... 1

More information

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with MB200 modules.

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with MB200 modules. 9- Section 9 NOTE: This section applies to applicators with MB200 modules. Table of Contents.................................................... 9- Introduction................................................

More information

2 8 CC Ejector Gun. Customer Product Manual Part

2 8 CC Ejector Gun. Customer Product Manual Part 2 8 CC Ejector Gun Customer Product Manual Issued 03/14 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

EcoLiner Compound Gun

EcoLiner Compound Gun EcoLiner Compound Gun Customer Product Manual Issued 3/06 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07 RediCoat by Nordson Hopper and VBF Dolly Systems Customer Product Manual Part 1082648A Issued 10/07 This document is subject to change without notice. Nordson Corporation Amherst, Ohio USA 2 Table of Contents

More information

EPS-8 and EPS-9 Electrostatic Power Supplies

EPS-8 and EPS-9 Electrostatic Power Supplies EPS-8 and EPS-9 Electrostatic Power Supplies Customer Product Manual Part For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your

More information

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G) Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 3100V 3400V 3500V Pump Piston (E, F, or G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0 A

More information

Circulating and Non-Circulating Color Change Manifolds

Circulating and Non-Circulating Color Change Manifolds Circulating and Non-Circulating Color Change Manifolds Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about

More information

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D Nordson Corporation OPERATOR S CARD P/N 321 198D Select Series H-440 Hot Melt Dispensing Guns Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions

More information

Prodigy HDLV Pump Manifold and Circuit Board

Prodigy HDLV Pump Manifold and Circuit Board Prodigy HDLV Pump Manifold and Circuit Board Customer Product Manual Issued 05/08 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document is available

More information

5000 Gerotor Pump Service Instructions

5000 Gerotor Pump Service Instructions Instruction Sheet P/N 237569B WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Introduction This

More information

E-350 Electric Gun. Customer Product Manual Part A NORDSON CORPORATION D AMHERST, OHIO D USA

E-350 Electric Gun. Customer Product Manual Part A NORDSON CORPORATION D AMHERST, OHIO D USA E-350 Electric Gun Customer Product Manual Part 237 495A NORDON CORPORATION D AMHERT, OHIO D UA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address

More information

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Part A, Section 3 Model This section covers the following unit configurations: 3100V 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0

More information

Maintenance. Part A, Section 5. This section covers the following unit configurations.

Maintenance. Part A, Section 5. This section covers the following unit configurations. Part A, Section 5 This section covers the following unit configurations. Model 3100V 3400V 3830V 3860V 3890V 3930V Voltage 1, 2 Pump AC Gear (K or L) Manifold 4-Port (J)) Control Vista Standard (V) Vista

More information

Parts. Part B, Section 5. This section covers the following unit configurations Model 3500 Voltage 1. 2 Piston (E,) Issued 11/00

Parts. Part B, Section 5. This section covers the following unit configurations Model 3500 Voltage 1. 2 Piston (E,) Issued 11/00 Part B, Section 5 This section covers the following unit configurations Model 5 Voltage. Pump Piston (E,) Manifold -Port (A) Control UniScan Nordson Corporation Issued / B 5- Issued / 999 Nordson Corporation

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with a Universal in-out filter. Table of Contents Filter...................................................... 10-1 Introduction................................................

More information

Rhino SD2/XD2 Frames

Rhino SD2/XD2 Frames Rhino SD2/XD2 Frames Customer Product Manual 0308-0 Issued 03/8 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 33-939 or contact your local Nordson

More information

A7A Single and Dual Automatic Airless Spray Guns

A7A Single and Dual Automatic Airless Spray Guns A7A Single and Dual Automatic Airless Spray Guns Customer Product Manual Issued 8/06 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document is available

More information

E-200 Module Service Kit

E-200 Module Service Kit Instruction Sheet E-200 Module Service Kit 1. Introduction These instructions describe how to remove and replace the E-200 module. The instructions include the following: S S S S Safety Unit Preparation

More information

High-Capacity Continuous Flow Iso-Flo Voltage-Block System

High-Capacity Continuous Flow Iso-Flo Voltage-Block System High-Capacity Continuous Flow Iso-Flo Voltage-Block System Part For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your local Nordson

More information

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. DISPLACEMENT PUMP 308190 Rev. K 3000 psi (210 bar) MAXIMUM WORKING PRESSURE Model

More information

Section 8. Parts A8EN -09 -[AD -31SW/WP] AD31SW--MA--02 (formerly ) Issued 12/95. E 1995 Nordson Corporation All rights reserved

Section 8. Parts A8EN -09 -[AD -31SW/WP] AD31SW--MA--02 (formerly ) Issued 12/95. E 1995 Nordson Corporation All rights reserved Section 8 8-0 8-1 Section 8 1. Introduction To order parts, call the Nordson Customer Service Center at 800-241-8777 or your local Nordson representative. Use this five-column parts list, and the accompanying

More information

EP-2 Three-Piston Pump

EP-2 Three-Piston Pump EP- Three-Piston Pump Customer Product Manual Issued 0/ For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) -99 or contact your local Nordson representative.

More information

Econo-Coat Manual Powder Spray Gun

Econo-Coat Manual Powder Spray Gun Econo-Coat Manual Powder Spray Gun Customer Product Manual Issued 0/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your local

More information

Installing an H-200 Integral Right-Angle Module

Installing an H-200 Integral Right-Angle Module Instruction heet P/N 187 723A Installing an H-200 Integral Right-Angle Module WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this

More information

Installation Instructions for Series 3100V Low Level Indicator

Installation Instructions for Series 3100V Low Level Indicator Instruction Sheet P/N Installation Instructions for Series 3100V Low Level Indicator WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V Part B, Section 1 This section covers the following unit configurations. Model Voltage Pump Manifold Control 3100V 3400V 3500V 3700V All Piston (E) 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista Standard

More information

Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun

Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun Instruction Sheet P/N 237494_02 Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun WARNING! Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V Part B, Section 1 Model Voltage Pump Manifold Control This section covers the following unit configurations. 3500V 3700V 3800V 3900V All Piston (F) 4-Port (A) 6-Port (B or C) -Port (S or T) Vista Standard

More information

EP-2 Si Three-Piston Pump

EP-2 Si Three-Piston Pump EP- Si Three-Piston Pump Customer Product Manual Issued 0/ For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) -99 or contact your local Nordson representative.

More information

Pro-Meter Gear Metering Pump

Pro-Meter Gear Metering Pump Pro-Meter Gear Metering Pump Customer Product Manual Part 0808E-0 Issued 4/6 NORDSON CORPORATION AMHERST, OHIO USA tents Table of Contents Safety... Qualified Personnel... Intended Use... Regulations and

More information

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11 Part A, Section 3 This section covers the following unit configurations. Model All Voltage 1, 2, 3 Pump All Manifold All Control Vista Standard (V) A 3-0 A 3-1 Section A 3 WARNING: Allow only qualified

More information

High-Pressure Fluid Filters

High-Pressure Fluid Filters High-Pressure Fluid Filters Customer Product Manual Part 107971C02 NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products.

More information

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure INSTRUCTIONS DP-6376 Airless Spray Gun 5000 psi (345 bar) Maximum Working Pressure INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Table of Contents Warnings......................................

More information

Time Interval Control

Time Interval Control Time Interval Control Model CT-6 Part 4 495A NORDSON CORPORATION. AMHERST, OHIO. USA Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

A16A Inside Stripe Gun

A16A Inside Stripe Gun A6A Inside Stripe Gun Customer Product Manual Issued 5/0 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document is subject to change without notice.

More information

Standard and Conical AN Series Air Spray Nozzles

Standard and Conical AN Series Air Spray Nozzles Instruction Sheet P/N 107967E Standard and Conical AN Series Air Spray Nozzles Introduction The Nordson air spray nozzles described in this instruction sheet are categorized by their type of spray pattern:

More information

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion Instruction Sheet P/N 106501A03 Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment.

More information

Preventive Maintenance for Pail Melters

Preventive Maintenance for Pail Melters Instruction Sheet P/N Preventive Maintenance for Pail Melters 1. Introduction These procedures are recommended in addition to the standard preventive maintenance. Use them to keep yourvista controlled

More information

Miniature Soft Seat Fluid Pressure Regulator

Miniature Soft Seat Fluid Pressure Regulator Instruction Sheet P/N 1. Description The Nordson miniature soft seat fluid pressure regulator is designed for use with hydraulic and pneumatic medias. The regulator body and wetted parts are constructed

More information

E-200 O-rings Service Kit

E-200 O-rings Service Kit Instruction Sheet E-00 O-rings Service Kit. Introduction These instructions describe how to replace the o-rings in the E-00 gun module. It is necessary to remove and disassemble the module when replacing

More information

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with bead or slot modules.

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with bead or slot modules. 9-1 Section 9 NOTE: This section applies to applicators with bead or slot modules. Table of Contents... 9-1 Introduction... 9-3 Overview... 9-7 Service... 9-9 Adjusting a ClassicBlue Zero-Cavity... 9-9

More information

Mastic Gun. Customer Product Manual Part A. Issued 2/04 NORDSON CORPORATION AMHERST, OHIO USA

Mastic Gun. Customer Product Manual Part A. Issued 2/04 NORDSON CORPORATION AMHERST, OHIO USA Mastic Gun Customer Product Manual Issued 2/04 NORDSON CORPORTION MHERST, OHIO US Table of Contents Safety...................................... 1 Qualified Personnel........................ 1 Intended

More information

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY SPRAY GUN Series en it fr es pt de se TECHNICAL DATA Technical AZ3 HTE2 AZ3 HTE2 HVLP 1.0 80 180 1.3 10-15HTE 140 200 240 1.5 2.0 160

More information

SERVICE INSTRUCTIONS. Material Pump

SERVICE INSTRUCTIONS. Material Pump TM TM SERVICE INSTRUCTIONS Material Pump 9618 DESCRIPTION Model 9618 is designed for pumping petroleum products from the original container to a desired location. Due to its non-corrosive (aluminum and

More information

Spray Pressure Control Manifold

Spray Pressure Control Manifold Instruction Sheet P/N 0870G0 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Introduction The

More information

Encore HD Powder Spray System with Prodigy Pump Cabinet

Encore HD Powder Spray System with Prodigy Pump Cabinet Encore HD Powder Spray System with Prodigy Pump Cabinet Customer Product Manual Part 604979-06 Issued 05/8 For parts and technical support, call the Industrial Coating Systems Customer Support Center at

More information

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A Nordson Corporation OPERATOR S CARD P/N 052644A VL400 Melters Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other

More information

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G) Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 300V 3400V 3500V Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B or C) -Port (S or T) Vista Pattern

More information

Air Operated Diaphragm Pumps

Air Operated Diaphragm Pumps Instructions Air Operated Diaphragm Pumps 30898ZAC For fluid transfer applications. For professional use only. Only models marked with (*) are approved for use in European explosive atmosphere locations.

More information

This section contains: Coil Kit Seat E-200 Std Module, E-200 Std Plunger W/Ball Assy E-200 O-rings

This section contains: Coil Kit Seat E-200 Std Module, E-200 Std Plunger W/Ball Assy E-200 O-rings 7-1 ection 7 1. Introduction To order parts, call the Nordson Customer ervice Center at 800-241-8777 or your local Nordson representative. Use this five-column parts list and the accompanying illustration

More information

Instructions-Parts 3A2805M. environments psi (10.3 MPa, 103 bar) Maximum Working Fluid Pressure 80 psi (0.5 MPa, 5.5 bar) Maximum Air Pressure

Instructions-Parts 3A2805M. environments psi (10.3 MPa, 103 bar) Maximum Working Fluid Pressure 80 psi (0.5 MPa, 5.5 bar) Maximum Air Pressure Instructions-Parts InvisiPac GS35 Plug-Free Hot Melt Applicator 3A2805M EN For dispensing hot melt adhesive. For professional use only. Not for use in waterwash environments. Not approved for use in explosive

More information

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with M-style cordsets.

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with M-style cordsets. Electrical System - Section Electrical System NOTE: This section applies to applicators with M-style cordsets. Table of Contents Electrical System........................................... - Introduction................................................

More information

Low-Pressure Color Change Manifold

Low-Pressure Color Change Manifold Low-Pressure Color Change Manifold Customer Product Manual Issued 0/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 33-939 or contact your local

More information

Spray Pressure Control Manifold

Spray Pressure Control Manifold Instruction Sheet P/N 0870-0 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Introduction The

More information

Air Operated Diaphragm Pumps

Air Operated Diaphragm Pumps Instructions Air Operated Diaphragm Pumps 30898W 00 psi (0.7 MPa, 7 bar) Maximum Fluid Working Pressure 00 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure ACETAL, POLYPROPYLENE, AND PVDF Husky 55 Model

More information

T1-Titanium Non-HVLP Spray Gun

T1-Titanium Non-HVLP Spray Gun T1-Titanium Non-HVLP Spray Gun THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.

More information

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with C-style cordsets.

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with C-style cordsets. Electrical System - Section Electrical System NOTE: This section applies to applicators with C-style cordsets. Table of Contents Electrical System........................................... - Introduction................................................

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V Part B, Section 1 Model Voltage Pump Manifold Control This section covers the following unit configurations. 3500V 3700V 3860 3890 3930 3960 All Piston (D) 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista

More information

Ink-Dot Hydraulic System with Reservoir Manifold

Ink-Dot Hydraulic System with Reservoir Manifold Ink-Dot Hydraulic System with Reservoir Manifold Customer Product Manual Issued 7/10 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 This

More information

Blow Off Valve Retrofit Kit

Blow Off Valve Retrofit Kit Instruction Sheet P/N 37 56C low Off Valve Retrofit Kit WRNING: llow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation..

More information

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: OPERATOR S MANUAL 650719-C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 8-11-03 REVISED: 12-3-10 (REV. 08) 2" DIAPHRAGM PUMP U.L. LISTED, 1:1 RATIO, METALLIC READ THIS MANUAL CAREFULLY BEFORE

More information

Auto-Flo II Anti-Drool Dispense Valves

Auto-Flo II Anti-Drool Dispense Valves Auto-Flo II Anti-Drool Dispense Valves Customer Product Manual Issued 0/9 For parts and technical support, call the Finishing Customer Support Center at (800) 33-939. This document is subject to change

More information

Tribomatic II Extended Automatic Powder Spray Gun

Tribomatic II Extended Automatic Powder Spray Gun Tribomatic II Extended Automatic Powder Spray Gun Customer Product Manual Issued 7/06 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact

More information

World Gun Series. Customer Product Manual Part C. Issued 11/03. NORDSON CORPORATION DULUTH, GEORGIA USA

World Gun Series. Customer Product Manual Part C. Issued 11/03. NORDSON CORPORATION DULUTH, GEORGIA USA World Gun Series Customer Product Manual Issued 11/03 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information,

More information