1 DANGER REMOTE SOURCE(S) OF POWER. DISCONNECT ALL SOURCES OF POWER BEFORE OPENING THE DOOR. ENERGY STORAGE CAPACITORS. VERIFY LOW VOLTAGE DISCHARGE BEFORE SERVICING. SEE INSTRUCTION MANUAL. Document Update PowerFlex 700 User Manual Update This document provides new information for the PowerFlex 700 Series B User Manual (publication 20B-UM002A-EN-P). Included is new information pertaining to s 5 & 6, NEMA Type 12 drives. Place this document with your User Manual for future reference. Dimensions Figure 1 5 NEMA Type 12 Standalone 25.4 (1.00) (4.15) (24.00) (22.00) Air Outlet (62.00) ±1.5 (62.75 ±0.06) DANGER ELECTRICAL SHOCK HAZARD FROM (41.79) (5.51) 16.8 (0.66) 13.5 (0.53) Dia. 4 Places (See Note A) 12.7 (0.50) Dia. Lifting Holes (17.75) Max (16.75) (11.30) Note A: Mount with 0.50 Inch UNC Grade 5 or Higher Screws or M12 Material Class 5.6 or Higher Screws Use Flat Washer with each Fastener Air Inlet Dimensions are in millimeters and (inches) Approx. Weight (1) kg (lbs.) Description Drive Drive & Packaging 5 Standalone (226.0) (341.0) (1) Weights include HIM and Standard I/O.

2 SHLD SHLD BRAKE TERMINAL RATINGS WIRE RANGE: 14-1/0 AWG ( MM 2 ) TORQUE: 32 IN-LB (3.6 N-M) STRIP LENGTH: 0.67 IN (17 MM) GROUND TERMINAL RATINGS (PE) WIRE RANGE: 6-1/0 AWG (18-35 MM 2 ) TORQUE: 44 IN-LB (5 N-M) STRIP LENGTH: 0.83 IN (21 MM) POWER & DC TERMINAL RATINGS USE 75 C CU WIRE ONLY WIRE RANGE: 4-3/0 AWG (18-70 MM 2 ) TORQUE: 133 IN-LB (15 N-M) STRIP LENGTH: 1.02 IN (26 MM) 6 MM HEX KEY 300 VDC EXT PWR SPLY TERM (PS+, PS-) WIRE RANGE: AWG (0.5-4 MM 2 ) TORQUE: 5.3 IN-LB (0.6 N-M) STRIP LENGTH: 0.35 IN (9 MM) 6 MM HEX KEY DANGER RISK OF ELECTRIC SHOCK AND DEATH DANGER FIELD INSTALLED OPTIONS 2 PowerFlex 700 User Manual Update Figure 2 5 NEMA Type 12 Flange Mount (8.64) (19.69) 11.0 (0.43) (7.74) (18.82) 12.7 (0.50) Dia. Lifting Holes - 4 Plcs. Air Outlet (41.77) (5.02) (40.91) (17.74) OUTPUT INPUT AC (7.60) 53.2 (2.09) 11.0 (0.43) Ground M5 PEM Nut 5.5 (0.22) Dia. Holes for Supplied Mounting Hardware 40 Plcs (11.95) 2.3 (0.09) Compressed Gasket (7.30) 97.0 (3.82) 42.0 (1.65) (15.12) Dimensions are in millimeters and (inches) Approx. Weight (1) kg (lbs.) Description Drive Drive & Packaging 5 Flange Mount (136.0) (180.0) (1) Weights include HIM and Standard I/O.

3 PowerFlex 700 User Manual Update 3 Figure 3 5 Flange Mount - Cutout 3.78 (0.149) Dia. Holes (40 Places) in Minimum 14 GA. (1.9) Steel Mounting Surface. Deburr Pilot Holes and Drive Cutout (40.91) 10.0 (0.39) (18.03) (40.41) (37.34) (34.27) (31.20) (28.13) (25.06) (21.99) Cutout (40.12) (18.92) (15.85) (12.78) (9.71) (6.63) 90.5 (3.56) 12.5 (0.49) 59.0 (2.32) (5.16) (7.99) (10.83) (13.66) (16.50) (18.82) 10.0 (0.39) Dimensions are in millimeters and (inches)

4 4 PowerFlex 700 User Manual Update Figure 4 6 NEMA Type 12 Standalone (28.00) 24.1 (0.90) (4.90) (26.10) (72.00) (70.70) (50.40) (11.20) 16.8 (0.66) 13.5 (0.53) Dia. 4 Places (See Note A) 12.7 (0.50) Dia. Lifting Holes (19.20) Max. Note A: Mount with 0.50 Inch UNC Grade 5 or Higher Screws or M12 Material Class 5.6 or Higher Screws Use Flat Washer with each Fastener 8.0 (0.30) Air Inlet Dimensions are in millimeters and (inches) Approx. Weight (1) kg (lbs.) Description Drive Drive & Packaging 6 Standalone (390.0) (505.0) (1) Weights include HIM and Standard I/O.

5 PS- OUTPUT USE 75C COPPER WIRE ONLY, TORQUE 52 IN-LB (6 N-M) PowerFlex 700 User Manual Update 5 Figure 5 6 NEMA Type 12 Flange Mount 14.0 (0.60) (7.90) (23.00) (21.90) (4.17) (43.30) (42.40) (30.0) WIRE STRIP AWG PS+ 5.3 IN-LB (0.6 N-M) BR2 BR1 DC+ DC- U V W PE PE R S T1 T2 T3 L1 L2 T L (5.40) (5.00) 11.0 (0.43) (11.60) 2.4 (0.10) Compressed Gasket Ground M5 PEM Stud 5.5 (0.22) Dia. Holes for Supplied Mounting Hardware 44 Places (7.60) (5.20) 57.9 (2.30) (18.40) Dimensions are in millimeters and (inches) Approx. Weight (1) kg (lbs.) Description Drive Drive & Packaging 6 Flange Mount (220.0) (264.0) (1) Weights include HIM and Standard I/O.

6 6 PowerFlex 700 User Manual Update Figure 6 6 Flange Mount - Cutout (42.40) 3.78 (0.149) Dia. Holes (44 Places) in Minimum 14 GA. (1.9) Steel Mounting Surface. Deburr Pilot Holes and Drive Cutout (0.50) (20.90) (41.10) (38.20) (35.40) (32.60) (29.70) (26.90) (24.10) (21.20) Cutout (41.5) (18.40) (15.60) (12.70) (9.90) (7.00) (4.20) 35.0 (1.40) 44.0 (1.70) (4.80) (7.90) (10.90) (14.00) (17.10) (20.20) 12.0 (0.50) Dimensions are in millimeters and (inches) Ratings Fuse and ratings information have been added for these drives on the following pages.

7 PowerFlex 700 User Manual Update 7 Table A.C 400 Volt AC Input Protection Devices (See page 11 for Notes) Dual Element Time Delay Fuse Motor Circuit 140M Motor Starter with Adjustable Current Protector (4) Range (5)(6) Drive kw PWM Input Non-Time Circuit Catalog Rating Freq. Temp. Ratings Output Amps Delay Fuse Breaker (3) Number ND HD khz C Amps kva Cont. 1 Min. 3 Sec. Min. (1) Max. (2) Min. (1) Max. (2) Max. (8) Max. (8) Available Catalog Numbers (7) 400 Volt AC Input 20BC1P M-C2E-B16 20BC2P M-C2E-B25 M-D8E-B25 20BC3P M-C2E-B40 M-D8E-B40 20BC5P M-C2E-B63 M-D8E-B63 20BC8P M-C2E-C10 M-D8E-C10 M-F8E-C10 20BC M-C2E-C16 M-D8E-C16 M-F8E-C16 20BC M-C2E-C20 M-D8E-C20 M-F8E-C20 20BC M-C2E-C25 M-D8E-C25 M-F8E-C25 20BC M-F8E-C32 20BC M-F8E-C45 20BC BC BC BC BC (9) (9) BC (9) (9) BC (9) (9) BC (9) (9) BC (9) (9) BC (9) (9)

8 8 PowerFlex 700 User Manual Update Table A.D 480 Volt AC Input Protection Devices (See page 11 for Notes) Dual Element Time Delay Fuse Motor Circuit 140M Motor Starter with Adjustable Current Protector (4) Range (5)(6) Drive HP PWM Input Non-Time Circuit Catalog Rating Freq. Temp. Ratings Output Amps Delay Fuse Breaker (3) Number ND HD khz C Amps kva Cont. 1 Min. 3 Sec. Min. (1) Max. (2) Min. (1) Max. (2) Max. (8) Max. (8) Available Catalog Numbers (7) 480 Volt AC Input 20BD1P M-C2E-B16 20BD2P M-C2E-B25 20BD3P M-C2E-B40 M-D8E-B40 20BD5P M-C2E-B63 M-D8E-B63 20BD8P M-C2E-C10 M-D8E-C10 M-F8E-C10 20BD M-C2E-C16 M-D8E-C16 M-F8E-C16 20BD M-C2E-C16 M-D8E-C16 M-F8E-C16 20BD M-C2E-C25 M-D8E-C25 M-F8E-C25 -CMN BD M-F8E-C32 -CMN BD M-F8E-C45 -CMN BD M-F8E-C45 -CMN BD CMN BD CMN BD CMN CMN BD (9) (9) CMN BD (9) (9) BD (9) (9) BD (9) (9) BD (9) (9)

9 PowerFlex 700 User Manual Update 9 Table A.E 600 Volt AC Input Protection Devices (See page 11 for Notes) Dual Element Time Delay Fuse Motor Circuit 140M Motor Starter with Adjustable Current Protector (4) Range (5)(6) Drive HP PWM Input Non-Time Circuit Catalog Rating Freq. Temp. Ratings Output Amps Delay Fuse Breaker (3) Number ND HD khz C Amps kva Cont. 1 Min. 3 Sec. Min. (1) Max. (2) Min. (1) Max. (2) Max. (8) Max. (8) Available Catalog Numbers (7) 600 Volt AC Input 20BE1P M-C2E-B16 20BE2P M-C2E-B25 20BE3P M-C2E-B40 M-D8E-B40 20BE6P M-C2E-B63 M-D8E-B63 20BE9P M-C2E-C10 M-D8E-C10 M-F8E-C10 20BE M-C2E-C10 M-D8E-C10 M-F8E-C10 20BE M-C2E-C16 M-D8E-C16 M-F8E-C16 20BE M-C2E-C25 M-D8E-C25 M-F8E-C25 -CMN BE M-F8E-C25 -CMN BE M-F8E-C32 -CMN BE M-F8E-C45 -CMN BE CMN BE CMN BE (9) CMN (9) CMN BE (9) (9) CMN BE (9) (9) BE (9) (9)

10 10 PowerFlex 700 User Manual Update Table A.F 690 Volt AC Input Protection Devices (See page 11 for Notes) Dual Element Time Delay Fuse Drive kw PWM Input Non-Time Circuit Catalog Rating Freq. Temp. Ratings Output Amps Delay Fuse Breaker (3) Number ND HD khz C Amps kva Cont. 1 Min. 3 Sec. Min. (1) Max. (2) Min. (1) Max. (2) Max. (8) Max. (8) 690 Volt AC Input Motor Circuit Protector (4) 20BF (9) (9) BF (9) (9) BF (9) (9) BF (9) (9) BF (9) (9) BF (9) (9)

11 PowerFlex 700 User Manual Update 11 Notes: (1) Minimum protection device size is the lowest rated device that supplies maximum protection without nuisance tripping. (2) Maximum protection device size is the highest rated device that supplies drive protection. For US NEC, minimum size is 125% of motor FLA. Ratings shown are maximum. (3) Circuit Breaker - inverse time breaker. For US NEC, minimum size is 125% of motor FLA. Ratings shown are maximum. (4) Motor Circuit Protector - instantaneous trip circuit breaker. For US NEC minimum size is 125% of motor FLA. Ratings shown are maximum. (5) Bulletin 140M with adjustable current range should have the current trip set to the minimum range that the device will not trip. (6) Manual Self-Protected (Type E) Combination Motor Controller, UL listed for 208 Wye or Delta, 240 Wye or Delta, 480Y/277 or 600Y/ 347. Not UL listed for use on 480V or 600V Delta/Delta systems. (7) The AIC ratings of the Bulletin 140M Motor Protector may vary. See publication 140M-SG001B-EN-P. (8) Maximum allowable rating by US NEC. Exact size must be chosen for each installation. (9) UL Type 12/IP54 (flange mount) heatsink ambient temperature rating is 40 C/ambient of unprotected drive portion (inside enclosure) is 55 C. The ambient temperature for the UL Type 12/ IP54 Standalone drives is 40 C.

12 12 PowerFlex 700 User Manual Update Table A.G 540 Volt DC Input Protection Devices Drive kw DC Input Catalog Rating Ratings Output Amps Number ND HD Amps kw Cont. 1 Min. 3 Sec. Fuse Bussmann Style Fuse 540 Volt DC Input 20BC1P3 (2) BUSSMANN_JKS-3 20BC2P1 (2) BUSSMANN_JKS-6 20BC3P5 (2) BUSSMANN_JKS-8 20BC5P0 (2) BUSSMANN_JKS-10 20BC8P7 (2) BUSSMANN_JKS-20 20BC011 (2) BUSSMANN_JKS-25 20BC015 (2) BUSSMANN_JKS-30 20BC022 (2) BUSSMANN_JKS-45 20BC030 (2) BUSSMANN_JKS-60 20BC037 (2) BUSSMANN_JKS-80 20BC043 (2) BUSSMANN_JKS-90 20BC056 (2) BUSSMANN_JKS BC072 (2) BUSSMANN_JKS BC085 (2) BUSSMANN_JKS BUSSMANN_JKS BH105 (1)(2) BUSSMANN_JKS BUSSMANN_JKS BH125 (1)(2) BUSSMANN_JKS BH140 (1)(2) BUSSMANN_JKS BUSSMANN_JKS BH170 (1)(2) BUSSMANN_JKS BUSSMANN_JKS BH205 (1)(2) BUSSMANN_JKS BUSSMANN_JKS-350 (1) Also applies to P voltage class. (2) UL Type 12/IP54 (flange mount) heatsink ambient temperature rating is 40 C/ambient of unprotected drive portion (inside enclosure) is 55 C. The ambient temperature for the UL Type 12/IP54 Standalone drives is 40 C.

13 PowerFlex 700 User Manual Update 13 Table A.H 650 Volt DC Input Protection Devices Drive Catalog Number 650 Volt DC Input kw Rating DC Input Ratings Output Amps ND HD Amps kw Cont. 1 Min. 3 Sec. Fuse Bussmann Style Fuse 20BD1P1 (2) BUSSMANN_JKS-6 20BD2P1 (2) BUSSMANN_JKS-6 20BD3P4 (2) BUSSMANN_JKS-6 20BD5P0 (2) BUSSMANN_JKS-10 20BD8P0 (2) BUSSMANN_JKS-15 20BD011 (2) BUSSMANN_JKS-20 20BD014 (2) BUSSMANN_JKS-30 20BD022 (2) BUSSMANN_JKS-45 20BD027 (2) BUSSMANN_JKS-60 20BD034 (2) BUSSMANN_JKS-70 20BD040 (2) BUSSMANN_JKS-80 20BD052 (2) BUSSMANN_JKS BD065 (2) BUSSMANN_JKS BD077 (2) BUSSMANN_JKS BUSSMANN_JKS BR096 (1)(2) BUSSMANN_JKS BUSSMANN_JKS BR125 (1)(2) BUSSMANN_JKS BUSSMANN_JKS BR156 (1)(2) BUSSMANN_JKS BUSSMANN_JKS BR180 (1)(2) BUSSMANN_JKS BUSSMANN_JKS-300 (1) Also applies to J voltage class. (2) UL Type 12/IP54 (flange mount) heatsink ambient temperature rating is 40 C/ambient of unprotected drive portion (inside enclosure) is 55 C. The ambient temperature for the UL Type 12/IP54 Standalone drives is 40 C.

14 Corporate Headquarters Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, USA, Tel: (1) , Fax: (1) Headquarters for Allen-Bradley Products, Rockwell Software Products and Global Manufacturing Solutions Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI USA, Tel: (1) , Fax: (1) Europe/Middle East/Africa: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) , Fax: (32) Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) , Fax: (852) Headquarters for Dodge and Reliance Electric Products Americas: Rockwell Automation, 6040 Ponders Court, Greenville, SC USA, Tel: (1) , Fax: (1) Europe/Middle East/Africa: Rockwell Automation, Herman-Heinrich-Gossen-Strasse 3, Köln, Germany, Tel: 49 (0) , Fax: 49 (0) Asia Pacific: Rockwell Automation, 55 Newton Road, #11-01/02 Revenue House, Singapore , Tel: (65) , Fax: (65) U.S. Allen-Bradley Drives Technical Support Tel: (1) , Fax: (1) , support@drives.ra.rockwell.com, Online: Publication 20B-DU008B-EN-P September, 2005 P/N C02 Supersedes 20B-DU008A-EN-P May, 2005 Copyright 2005 Rockwell Automation, Inc. All rights reserved. Printed in USA.

Drive, Fuse & Circuit Breaker Ratings

Drive, Fuse & Circuit Breaker Ratings Fuses 1, Fuse & Breaker s The tables on the following pages provide drive ratings (including continuous, 1 minute and 3 second) and recommended AC line input fuse and circuit breaker information. Both

More information

1370 DC Loop Contactors and Lug Kits

1370 DC Loop Contactors and Lug Kits Installation Instructions 1370 DC Loop Contactors and Lug Kits 1370 DC Contactors are electromagnetically held contactors specially designed to switch the armature current from a DC drive module to a shunt

More information

Example Maintenance Schedule 1. The attached document is an example of an acceptable maintenance schedule.

Example Maintenance Schedule 1. The attached document is an example of an acceptable maintenance schedule. IRRIGATION TRAINING & RESEARCH CENTER California Polytechnic State University San Luis Obispo, CA 93407-0730 Phone: 805.756.2434 FAX: 805.756.2433 www.itrc.org Example Maintenance Schedule 1 The attached

More information

841XL PREMIUM EFFICIENCY MOTORS

841XL PREMIUM EFFICIENCY MOTORS 841XL PREMIUM EFFICIENCY MOTORS 8 4 1 X L A C M O T O R S D E S I G N E D T O M E E T Y O U R S E V E RE D U T Y N E E D S As an original member of the NEMA Energy Task Force, Rockwell Automation has

More information

The Complete Range up to 710 kw. Overview Contactors

The Complete Range up to 710 kw. Overview Contactors The Complete Range up to 710 kw Overview Contactors Rockwell Automation Contactors - the Complet Motor rating AC-3, 400 V 2.2 kw 4.0 kw 5.5 kw 4 kw 5.5 kw 7 Rated operational current 60 C AC-3, 400 V [A]

More information

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control Selection Guide for SMC-Delta and SMC-3 A New Dimension in Motor Control Discover a New Dimension in Motor Control: SMC-Delta and SMC-3 The Allen-Bradley SMC-Delta and SMC-3 softstarters from Complete

More information

PowerFlex 700H and 700S AC Drives Frame 9 Main Fan Capacitor Replacement Kit

PowerFlex 700H and 700S AC Drives Frame 9 Main Fan Capacitor Replacement Kit Installation Instructions PowerFlex 700H and 700S AC Drives Frame 9 Main Fan Capacitor Replacement Kit ATTENTION: This drive contains ESD (Electrostatic Discharge) sensitive parts and assemblies. Static

More information

Lifting & Mounting PowerFlex 700S and 700H Drives (Frames 10-14)

Lifting & Mounting PowerFlex 700S and 700H Drives (Frames 10-14) Installation Instructions Lifting & Mounting PowerFlex 700S and 700H s (Frames 10-14) General Precautions! TTENTION: To guard against possible personal injury and/or equipment damage Do Not allow any part

More information

PowerFlex DC Drive - Frame C Field SCR Module

PowerFlex DC Drive - Frame C Field SCR Module Installation Instructions PowerFlex DC Drive - Frame C Field SCR Module!!! ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should plan or implement the installation,

More information

Installation, Operation And Maintenance of. AC and DC Mine Motors

Installation, Operation And Maintenance of. AC and DC Mine Motors Installation, Operation And Maintenance of AC and DC Mine Motors Instruction Manual B-3623-1 June, 2003 Table of Contents General Safety/Acceptance Instructions..2 Installation Instructions. 3 Operating

More information

VARIABLE SPEED AC MOTORS 1/3-2,500 HP INVERTER DUTY MOTORS

VARIABLE SPEED AC MOTORS 1/3-2,500 HP INVERTER DUTY MOTORS VARIABLE SPEED AC MOTORS 1/3-2,500 HP INVERTER DUTY MOTORS IN 1904, RELIANCE ELECTRIC INTRODUCED THE WORLD'S FIRST VARIABLE SPEED MOTOR. FOR OVER 96 YEARS, RELIANCE ELECTRIC MOTORS HAVE LED THE INDUSTRY

More information

PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board

PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board Installation Instructions PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should plan or implement the

More information

FlexPak 3000 DC Drives and WebPak 3000 DC Drives Replacement Parts

FlexPak 3000 DC Drives and WebPak 3000 DC Drives Replacement Parts FlexPak 000 DC s and WebPak 000 DC s Replacement Parts Instruction Manual D-48-5 Effective Date: March, 007! ATTENTION: Only qualified electrical personnel familiar with the construction of this equipment

More information

UNIT CONVEYOR SYSTEMS

UNIT CONVEYOR SYSTEMS UNIT CONVEYOR SYSTEMS PRE-ENGINEERED VARIABLE SPEED DRIVE PACKAGES Pre-engineered drive package assemblies combine the strength of Dodge and Reliance products to provide a total variable speed unit conveying

More information

PowerFlex 700 Adjustable Frequency AC Drive

PowerFlex 700 Adjustable Frequency AC Drive Technical Data PowerFlex 700 Adjustable Frequency AC Drive Topic Page Product Overview 2 Certifications and Specifications 7 Design Considerations 12 Drive, Fuse and Circuit Breaker Ratings 24 Cable Recommendations

More information

PowerFlex 700 Adjustable Frequency AC Drive

PowerFlex 700 Adjustable Frequency AC Drive Technical Data PowerFlex 700 Adjustable Frequency AC Drive Topic Page Product Overview 2 Certifications and Specifications 8 Design Considerations 13 Drive, Fuse and Circuit Breaker Ratings Cable Recommendations

More information

DODGE QUANTIS MAKES THE GLOBAL CONNECTION

DODGE QUANTIS MAKES THE GLOBAL CONNECTION DODGE QUANTIS MAKES THE GLOBAL CONNECTION HOLLOW SHAFT SOLID SHAFT DOUBLE ENDED SOLID SHAFT HOLLOW SPLINED SHAFT SHRINK DISK CONNECTION SHAFT RHB FOOTLESS FLANGE RHB FOOT MOUNTED NE SEPARA ARATE C Output

More information

1204 Terminator. Instructions 1204 T F B2. (Catalog Number 1204-TFA1, 1204-TFB2) Where this Option is Used. What this Option Contains

1204 Terminator. Instructions 1204 T F B2. (Catalog Number 1204-TFA1, 1204-TFB2) Where this Option is Used. What this Option Contains Instructions 1204 Terminator (Catalog Number 1204-TFA1, 1204-TFB2) Where this Option is Used The 1204 Terminator Option can be installed in most adjustable frequency AC drive applications to increase protection

More information

PowerFlex 700 Adjustable Frequency AC Drive

PowerFlex 700 Adjustable Frequency AC Drive Technical Data PowerFlex 700 Adjustable Frequency AC Drive Topic Page Product Overview 2 Certifications and Specifications 7 Design Considerations 12 Drive, Fuse and Circuit Breaker Ratings 24 Cable Recommendations

More information

1321 Power Conditioning Products

1321 Power Conditioning Products Technical Data 1321 Power Conditioning Products Don t Ignore the Cost of Power Line Disturbance Topic Page Product Overview 2 1321-3R and 3RA Series Line Reactors 3 1321 Reflective Wave Reduction (RWR)

More information

These documents contain additional information concerning related products from Rockwell Automation.

These documents contain additional information concerning related products from Rockwell Automation. Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Title PowerFlex 750-Series Drive Installation Instructions PowerFlex 750-Series

More information

PHOTOSWITCH Liquid Level and Resistance Sensing Control Bulletin 13DJ3-3000

PHOTOSWITCH Liquid Level and Resistance Sensing Control Bulletin 13DJ3-3000 Liquid Level and Resistance Sensing Control Bulletin 3DJ3-3000 Product Data Description Features The Photoswitch Bulletin is a high sensitivity Liquid Level Control designed to detect the level of conductive

More information

External Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s LF200405xxx, LF200460xxx, LF200520xxx, LF200608xxx

External Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s LF200405xxx, LF200460xxx, LF200520xxx, LF200608xxx External us Resistor Kit for LiquiFlo Drives Drive M/N s LF200405xxx, LF200460xxx, LF200520xxx, LF200608xxx Instruction Manual D2-3538!!!!! TTENTION: Only qualified electrical personnel familiar with the

More information

AC Drives Regenerative Energy Solutions. Product Summary

AC Drives Regenerative Energy Solutions. Product Summary AC Drives Regenerative Energy Solutions Product Summary #% &TKXGU Regenerative Energy Solutions Snubber Resistor Braking Kits Line Regeneration Controls Synchronous Rectifier Controls AC Drives and Regenerative

More information

Installation Data. Allen-Bradley 1336/1336VT/1336 PLUS/PLUS II/IMPACT 1336 FORCE Drives Dynamic Braking

Installation Data. Allen-Bradley 1336/1336VT/1336 PLUS/PLUS II/IMPACT 1336 FORCE Drives Dynamic Braking Installation Data Allen-Bradley 336/336VT/336 PLUS/PLUS II/IMPACT 336 FORCE Drives Dynamic Braking Series D Cat. No. 336-MOD-KA005, KB005 and KC005 Series D Cat. No. 336-MOD-KA00, KB00 and KC00 Series

More information

Resistive Brake Module

Resistive Brake Module Installation Instructions Resistive Brake Module (Catalog Numbers 2090-XB33-16, 2090-XB33-32, 2090-XB120-01, 2090-XB120-03, and 2090-XB120-06 This publication provides installation instructions for the

More information

World-Class Motion Control with Worldwide Support

World-Class Motion Control with Worldwide Support Rockwell Automation is an automation leader who not only develops innovative technology, but has the expertise and global supply network to be your complete automation solution provider. Rockwell Automation

More information

Installation Instructions

Installation Instructions Installation Instructions Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Operating Mechanisms For use with Circuit Breakers 140G-G, 140MG-G, 140G-H, 140MG-H, 140G-I, 140MG-I, 140G-J, 140MG-J,

More information

Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

Motors  GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2 GRUNDFOS GROUNDWATER SERVICE MANUAL Motors 4-6-8-10" CONTENTS Grundfos Motor Specifications... Page 2 Electrical Requirements... Page 8 -Transformer Capacity Maximum Motor Cable Length... Page 10 Full

More information

CENTERLINE 2100 Motor Control Centers

CENTERLINE 2100 Motor Control Centers TECHNICAL DATA CENTERLINE 2 Motor Control Centers Instantaneous Trip Motor Circuit Protectors (MCP) in Combination NEMA Starter, Soft Starter (SMC) and Variable Frequency AC Drive Units 1A Frame Instantaneous

More information

BR Second Position Voltages. AA Fourth Position

BR Second Position Voltages. AA Fourth Position 1336S First Position Bulletin Number BR Second Position Voltage Letter AQ BR CW A B BP BX C Q R RX W Voltages 200-240V AC or 3V DC 380-480VAC or 513-620V DC 500-600V AC or 775V DC or 200-240V AC 380-480V

More information

Synergy EN product information

Synergy EN product information Synergy EN60947-4-2 product information Rated operational voltages U e 200Vac to 480Vac Rated operational currents I e See Rating Table Rating index See Sizing Guide Rated frequency/frequencies 50-60Hz

More information

1329I Integrated Drive/Motor CE Filter Option Kit

1329I Integrated Drive/Motor CE Filter Option Kit Instruction Sheet 1329I Integrated Drive/Motor CE Filter Option Kit CE filter options are designed to be used with the 1329I Integrated Drive/Motor. The main function of the CE filter is to reduce the

More information

Lifting Instructions for 1336 PLUS and FORCE D Frame Drives

Lifting Instructions for 1336 PLUS and FORCE D Frame Drives Installation Instructions Lifting Instructions for 1336 PLUS and FORCE D Frame Drives This publication will guide you through the steps needed to properly lift and mount the following drives: 1336 PLUS

More information

IEC Starter Approximate Dimensions

IEC Starter Approximate Dimensions Technical Data IEC Starter Approximate Dimensions Bulletin Numbers 103H/107H/140M, 103-C/107/C, 105, 109, 106, 112, 113, 190E/191E, 190S/191S, 103S/107S, 103T/107T Topic Page Enclosed Starters and Motor

More information

Packing Data Installation Instructions

Packing Data Installation Instructions Packing Data PK Installation Instructions This document describes how to install a Dataliner DL10 display in a panel or enclosure and connect power. European Union Directive Compliance wiring and safety

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

PowerFlex 700L. Technical Data. Catalog Number 20L. Original Instructions

PowerFlex 700L. Technical Data. Catalog Number 20L. Original Instructions Technical Data PowerFlex 700L Catalog Number 20L Topic Page Product Overview 2 Key Features/Benefits 2 Communication and Human Interface Options 4 Catalog Number Explanation 6 Standard Drive Product Selection

More information

Trane Liqui-Flo Addendum. Instruction Manual D2-3415

Trane Liqui-Flo Addendum. Instruction Manual D2-3415 Trane Liqui-Flo Addendum Instruction Manual D2-3415 The information in this manual is subject to change without notice. Throughout this manual, the following notes are used to alert you to safety considerations:!

More information

Technical Data. PowerFlex 70 AC Drives

Technical Data. PowerFlex 70 AC Drives Technical Data PowerFlex 70 AC Drives Product Overview PowerFlex 70 AC Drive Technical Data Optimized Simplicity PowerFlex 70 drives are designed to worldwide standards and ratings, allowing out-ofthe-box

More information

Compact Circuit Protector

Compact Circuit Protector Technical Data 10801 Supersedes August 018 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP) Contents Page 011/65/EU and specifications.... -3 Catalog numbers.... 4 Conductor information and available

More information

Technical Data. PowerFlex 700 Adjustable Frequency AC Drives

Technical Data. PowerFlex 700 Adjustable Frequency AC Drives Technical Data PowerFlex 700 Adjustable Frequency AC Drives Product Overview PowerFlex 700 Adjustable Frequency AC Drives Technical Data The PowerFlex 700 AC drive offers outstanding performance in an

More information

PowerFlex 700L TECHNICAL DATA LIQUID-COOLED ADJUSTABLE FREQUENCY AC DRIVES

PowerFlex 700L TECHNICAL DATA LIQUID-COOLED ADJUSTABLE FREQUENCY AC DRIVES PowerFlex 700L TECHNICAL DATA LIQUID-COOLED ADJUSTABLE FREQUENCY AC DRIVES Table of Contents Description.................................................. Page Product Overview.................................................3

More information

Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101

Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101 Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101 Instruction Manual D2-3302-3 The information in this manual is subject to change without notice. Throughout

More information

SUPPLEMENT MANUAL IM250R03. AQUAVAR CPC SUPPLEMENT A - Variable Speed Drive SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167)

SUPPLEMENT MANUAL IM250R03. AQUAVAR CPC SUPPLEMENT A - Variable Speed Drive SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167) SUPPLEMENT MANUAL IM250R03 AQUAVAR CPC SUPPLEMENT A - Variable Speed Drive SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167) TABLE OF CONTENTS SAFETY Use of Warnings and Notes...3 INSTALLATION

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

Kinetix 5700 Capacitor Modules

Kinetix 5700 Capacitor Modules Installation Instructions Kinetix 5700 s Catalog Numbers 98-CAP-40, 98-CAP-DCBUS-IO Topic Page About the s Before You Begin Install the s Connector Data 6 Wiring Requirements 8 Additional Resources Summary

More information

PowerFlex 750-Series AC Drives

PowerFlex 750-Series AC Drives Technical Data PowerFlex 7-Series AC Drives Original Instructions Topic Page Additional Resources 2 Product Overview 2 Certifications and Specifications 6 Design Considerations 11 Fuse and Circuit Breaker

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 40-75 HP @ 230 VAC and 75-150 HP @ 460 VAC Model Numbers: 906FK1101 and 906FK1201 Instruction Manual D2-3330-2! ATTENTION:

More information

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications Technical Data Motor Protection Circuit Breaker and Motor Circuit Protector Specifications Bulletin Number 140M Topic Page Bulletin 140M Motor Protection Circuit Breakers 3 Overview 3 Catalog Number Explanation

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes April 2014 UL Class CC, CF (CUBEFuse ), Midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-Pole Class CC, Midget, 10x38mm Description & Specifications....

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

Bulletin 140M Motor Protectors

Bulletin 140M Motor Protectors 0Circuit Breaker Bulletin 140M Bulletin 140M Cat. No. 140M-C2E Cat. No. 140M-F8E Current Range 0.1...45 A With 140-CMN up to 90 A Type 2 Coordination with Bulletin 100-C Contactors UL Listed Self-protected

More information

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control

More information

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz Catalog Number Explanation Open Controllers a Bulletin Number Solid-State Controller B H H B B B B B B B B B B B B B Solid-State Controller and Isolation Contactor (enclosed only) b Controller Ratings

More information

Product Information Packet ECP40802S HP,3600,2300/4000,TEFC-SD,

Product Information Packet ECP40802S HP,3600,2300/4000,TEFC-SD, Product Information Packet ECP40802S-2340 800 HP,3600,2300/4000,TEFC-SD, Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 1794-ASB Series B) 1 9 2 3 4, 5 6 7 8 Component Identification 1 Remote I/O Adapter module 2 Indicators 3 Communication reset pushbutton (PRL) 4 Access door to switches

More information

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016 Supersedes April 2016 BUSSMANN SERIES CUBEFuse Compact Circuit Protector Base (CCPB) 2011/65/EU Features and benefits: Uses finger-safe, current-limiting Class CF CUBEFuse with Class J performance available,

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

Allen-Bradley 1397 Pulse Encoder Interface Card

Allen-Bradley 1397 Pulse Encoder Interface Card Installation Instructions IN Allen-Bradley 1397 Pulse Encoder Interface Card Cat. No. 1397-PE Table of Contents What This Option Provides........................ 1 Where This Option Is Used........................

More information

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable

More information

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA: Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD

More information

THE BULLETIN 509 ASSEMBLY GUIDE - Features and Benefits

THE BULLETIN 509 ASSEMBLY GUIDE - Features and Benefits m 5 PRODUCT BULLETIN w DATA 509 I THE BULLETIN 509 ASSEMBLY GUIDE - and Publication 509-2.1 -June, 1990 Supersedes Publication MC- 130 Dated September, 1979 Allen-Bradley quality is more than a slogan.

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes March 2016 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail 2011/65/EU Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description

More information

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm Supersedes October 2015 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description and

More information

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide Retain for future use. 30072-450-47A July 2002 Raleigh, NC, USA HAZARDOUS VOLTAGE Read and understand

More information

Double Pole Circuit Breaker Kit for Non-Regenerative MinPak Plus DC Drives

Double Pole Circuit Breaker Kit for Non-Regenerative MinPak Plus DC Drives Double Pole Circuit Breaker Kit for Non-Regenerative MinPak Plus DC Drives Model Numbers 14C210, 14C211, 14C212, and 14C213 Instruction Manual D2-3385! ATTENTION: Only qualified electrical personnel familiar

More information

Pneumatic Isolation Module

Pneumatic Isolation Module Pneumatic Isolation Module (Cat. 2030-Pxxxxx) ATTENTION: Hazardous Voltage or other forms of energy could be present. To avoid serious injury or death: Prior to beginning the installation and wiring process,

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Short-Circuit Current Ratings

Short-Circuit Current Ratings UL 508 Type E Combination Motor Controller, TeSys GV Combination Meeting UL 508 Type E, UL File E164871 Table 2: TeSys GV2P Horsepower and SCCR Ratings In combination with line spacer GV2GH7 (stand-alone

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Selection Checklist CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Use this checklist to help you configure your CENTERLINE 2500 Motor Control Center. You can type in the fields

More information

SIGNAL WORDS QUALIFIED PERSON

SIGNAL WORDS QUALIFIED PERSON SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or

More information

Kinetix Rotary Motion Specifications

Kinetix Rotary Motion Specifications Technical Data Kinetix Rotary Motion Specifications Kinetix VP, MP-Series, Kinetix 6000M, TL-Series, HPK-Series, RDD-Series Topic Page Topic Page Kinetix VP Low Inertia Motors 2 Kinetix 6000M Integrated

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

[V] Common Control Transformer Control (See page 1-78 Note)

[V] Common Control Transformer Control (See page 1-78 Note) Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state

More information

SUPPLEMENT MANUAL IM250. AQUAVAR CPC - FD Variable Speed Drive with Fused Disconnect SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167)

SUPPLEMENT MANUAL IM250. AQUAVAR CPC - FD Variable Speed Drive with Fused Disconnect SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167) SUPPLEMENT MANUAL IM250 AQUAVAR CPC - FD Variable Speed Drive with Fused Disconnect SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167) TABLE OF CONTENTS SAFETY Use of Warnings and Notes...3 INSTALLATION

More information

More power to manufacturers. Improving electric vehicle production processes

More power to manufacturers. Improving electric vehicle production processes More power to manufacturers Improving electric vehicle production processes of the automotive powertrain The continuing story of innovation in the automotive industry shows no sign of coming to an end.

More information

Selection Guide. PowerFlex Digital DC Drive

Selection Guide. PowerFlex Digital DC Drive Selection Guide PowerFlex Digital DC Drive PowerFlex Digital DC Drive The PowerFlex DC drive combines powerful performance with flexible control to produce a highly functional, cost effective drive and

More information

INSTRUCTION MANUAL ADDEN600V R1 AQUAVAR CPC. (Centrifugal Pump Control) 600 VOLT ADDENDUM

INSTRUCTION MANUAL ADDEN600V R1 AQUAVAR CPC. (Centrifugal Pump Control) 600 VOLT ADDENDUM INSTRUCTION MANUAL ADDEN600V R1 AQUAVAR CPC (Centrifugal Pump Control) 600 VOLT ADDENDUM Cable Sizing/Ratings 500 600 Volt Drives The following table provides Aquavar CPC rating information and recommended

More information

Illustrated Parts List. Reproduction MODEL Not for. 10,000 Watt Standby Generator System

Illustrated Parts List. Reproduction MODEL Not for. 10,000 Watt Standby Generator System Illustrated Parts List MODEL 040375-00 040375-01 10,000 Watt Standby Generator System Manual Part No. 1756659 Revision A Rev. Date: 12/4/2013 Table Of Contents PRODUCT COMPONENTS PAGES Main Unit... 4

More information

2 SLR Series Line Reactors... 50

2 SLR Series Line Reactors... 50 Drive Isolation & Protection Line Reactors Drive Isolation Transformers 2 SLR Series Line Reactors... 50 Drive Isolation Transformers... 51 Selection Table and Design Styles... 52 Electrical Connections...

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090529 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW Line/Load Reactors are components designed to improve the

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

Medium Voltage Contactor

Medium Voltage Contactor Medium Voltage Contactor (Series D) Bulletin 1502 400A 2400 to 7200 volts User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical

More information

PERFORMANCE - DELTA CONNECTION LOAD HP AMPERES RPM % % SPEED TORQUE - WYE / DELTA CONNECTION RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT 61 / 219

PERFORMANCE - DELTA CONNECTION LOAD HP AMPERES RPM % % SPEED TORQUE - WYE / DELTA CONNECTION RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT 61 / 219 BALDOR -RELIANCE FRAME HP TYPE PHASE HERTZ RPM SALES ORDER 347778- E58 4 P 3 6 784 VOLTS AMPS DUTY AMB o C INSUL S.F. NEMA DESIGN 38 566 CONT 46 F.5 --- CODE ENCL. ROTOR WK STATOR RES.@5 o C LETTER (lb-ft

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 845-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-freemechanism and toggle actuation. A choice of switching characteristics

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Control and Load Switch Specifications Bulletin Number 194E, 194L

Control and Load Switch Specifications Bulletin Number 194E, 194L Technical Data Control and Load Switch Specifications Bulletin Number 194E, 194L Topic Page Product Line Overview 2 194E General Specifications 3 194E Approximate Dimensions 5 194L Circuit Diagrams 13

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

SECTION VARIABLE FREQUENCY DRIVE UNITS

SECTION VARIABLE FREQUENCY DRIVE UNITS SECTION 26 29 23 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide variable frequency drive (VFD) units, complete and operable, in accordance with the Contract Documents. It

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications The Reliance Electric LiquiFlo AC drive combines high-performance variable speed drive technology with a patented liquid-cooling

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses Technical Data 10789 BUSSMANN SERIES Next generation Compact Circuit Protector (cat. no. CCP2) Contents Page 2011/65/EU CCP2 switch and specifications.... 2-3 Catalog numbers.... 4 Conductor information

More information

Compact Circuit Protector

Compact Circuit Protector Supersedes February 2019 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP2) 2011/65/EU CCP2 switch up to 100 A 200 A CCP2 switch 400 A CCP2 switch Contents Page 30, 60 and 100 amp switches s and

More information