PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board

Size: px
Start display at page:

Download "PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board"

Transcription

1 Installation Instructions PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should plan or implement the installation, start-up and subsequent maintenance of the system. Failure to comply may result in personal injury and/or equipment damage. ATTENTION: To avoid an electric shock hazard, ensure that all power to the drive has been removed before performing the following. ATTENTION: This drive contains ESD (Electrostatic Discharge) sensitive parts and assemblies. Static control precautions are required when installing, testing, servicing or repairing this assembly. Component damage may result if ESD control procedures are not followed. If you are not familiar with static control procedures, reference A-B publication , uarding Against Electrostatic Damage or any other applicable ESD protection handbook. What This Kit Includes Pulse Transformer circuit board Six screws with washers 6 gate lead cables with connectors (for non-regenerative drives only) 12 gate lead cables with connectors (for regenerative drives only) Cables for connectors X3 (2 pin) and XP (34 pin) Cables for connector X4 (for drives with a fan only) Plug-in terminal block with 1k ohm terminals Isolation sheet Flathead screwdriver for terminal block connections Static strap Tools That You Need Phillips screwdriver Flathead screwdriver Nut driver or wrench for hex stand-offs Multimeter (capable of reading to a thousandth of an Ohm) Wire Cutter Phillips is a registered trademark of Phillips Screw Company.

2 2 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board What You Need to Do To install the Pulse Transformer board: Step 1: Step 2: Step 3: Step 4: Step 5: Step 6: Step 7: Step 8: Remove power from the drive Remove the protective covers Remove the Control EMI shield and Control board Remove the Pulse Transformer and Switching Power Supply boards Configure the new Pulse Transformer board Install the new Pulse Transformer board and existing Switching Power Supply board Install the Control EMI Shield and Control board Replace the protective covers and document the change Step 1: Remove Power from the Drive ATTENTION: Remove power before making or breaking cable connections. When you remove or insert a cable connector with power applied, an electrical arc may occur. An electrical arc can cause personal injury or property damage by: sending an erroneous signal to your system s field devices, causing unintended machine motion causing an explosion in a hazardous environment Electrical arcing causes excessive wear to contacts on both the module and its mating connector. Worn contacts may create electrical resistance. 1. Remove and lock-out all incoming power to the drive. L1 L2 L3 I O

3 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board 3 Step 2: Remove the Protective Covers 1. Disconnect the DPI cable from the HIM assembly (if present). 2. Remove the screws that secure the bottom cover to the drive, then slide the cover down and off the drive chassis. = Disconnect DPI cable Tightening torque: 1.5 N m (13.3.lb in) 3. Press in on the sides at the bottom edge of the top cover and at the same time pull the cover toward you to pull it partially off the drive chassis. 4. At the top of the drive, pull the cover forward, away from the drive, until the pins fit in the keyhole in the top of the cover, then carefully lift the cover off of the drive chassis. Important: The HIM assembly is connected via a cable to the Control board and therefore will not pull free from the drive until disconnected. See page 4 for instructions When metal pin fits in keyhole, lift cover off drive chassis.

4 4 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board 5. Disconnect the HIM Communication cable from the connector on the upper right corner of the Control board and set the cover aside. Pull tabs out to disconnect cable.

5 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board 5 Step 3: Remove the Control EMI Shield and Control Board 1. Carefully disconnect the cables from connectors XFCD, XA and XR on the Control board. 2. Remove all appropriate I/O and control wiring including: digital and analog I/O plug-in terminal blocks on the Control board analog tachometer terminal block on the Control board encoder terminal block on the Control board cable shields that are grounded to the Control EMI shield I/O terminal blocks on the I/O Expansion board I/O terminal blocks on the 115V AC to 24V DC I/O Converter board = Disconnect cables XFCD, XA, and XR Disconnect I/O and control wiring Note: Control board shown with Communication Adapter and optional boards removed.

6 6 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board 3. Remove the five screws that secure the ground wire (in the lower left corner) and Control EMI shield to the chassis and slide the Control EMI shield and Control board up and out of the drive. Important: Be careful when removing the EMI shield not to pull free any of the gate leads or other cables on the Pulse Transformer circuit board below the EMI shield. Remove screws Remove screw and ground wire Step 4: Remove the Pulse Transformer and Switching Power Supply Boards Note: The Switching Power Supply circuit board is located on the back of the Pulse Transformer circuit board. You must remove both boards in order to replace the Pulse Transformer board.

7 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board 7 1. Remove the slotted air flow plate from the top of the drive: For 38A and 55A 230V AC input and 35A, 45A, and 52A 460V AC input, remove the four screws that secure the slotted air flow plate to the top of the drive, remove the fan cable from connector XV on the Switching Power Supply board and remove the plate and connected fan. = Remove screws For all other drives, remove the two screws that secure the slotted air flow plate to the top of the drive and remove the plate. = Remove screw Air flow plate Remove screw

8 8 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board Figure 1 Pulse Transformer Circuit Board Layout Components shown within dashed lines are only on the Pulse Transformer board for regenerative drives. XSW XP X3 XSW1 TR2 TR1 X4 XR XCD_IO XY TO1 TO4 TO2 TO5 TO3 TO6 KO1 KO4 KO2 KO5 KO3 KO6 T1 T4 T2 T5 T3 T6 K1 K4 K2 K5 K3 K6 XTA S4 1 1 FIR1-XX rev. Q and higher U2 V2 S3 U C V W T04 T01 K K K04 K01 T1 T4 K K1 K K4 W V C U X3 1 XSW1 1 XSW 6 1 XP 1 TR2 TR1 X4 2 XR V1 XY 1 T02 T05 T03 T06 K K02 K05 K K03 K T2 T3 T5 T6 K K2 K5 K K K3 K6 K FIR1-XX rev. P and lower K06 K XTA 1 TA U2 V2

9 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board 9 Important: Mark all connections and wires before removal to avoid incorrect wiring during reassembly. 2. Remove the plug-in control power terminal block from the Pulse Transformer circuit board. Remove plug-in terminal block 3. Remove the cables from connectors X3, X4 and XP on the Pulse Transformer board. Note: Connector X4 contains a jumper for drives without a fan - leave in place. Remove cables from X3, X4 and XP 4. For Pulse Transformer boards with an armature voltage feedback terminal block, FIR1-XX, rev Q and higher, remove the connector from XCD_IO on the upper left corner of the board. X3 XSW1 XSW XP Remove connector from XCD_IO X4 TR2 TR1 XR XCD_IO XY

10 10 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board 5. Remove the appropriate gate leads: For regenerative drives, remove each pair of (orange and yellow) gate lead cables from connectors K01 K06 and K1 K6 and push each lead through the appropriate opening in the board. For non-regenerative drives, remove each pair of (orange and yellow) gate lead cables from connectors K01 K06 and push each lead through the appropriate opening in the board. Important: Remove the gate leads by grasping the connector and pulling up. DO NOT pull the gate leads off by pulling on the wires. 6. Remove the cable from connectors XTA on the Pulse Transformer board. For regenerative drives, remove 12 gate leads and push through holes in board Remove cable from XTA For non-regenerative drives, remove six gate leads and push through holes in board Remove cable from XTA

11 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board Remove the six screws that secure the bottom of the Pulse Transformer board to the drive and, while lifting up slightly on the board, slide it toward the top of the drive and out of the chassis. Important: The cables from connectors X4 and XTA must slide through the openings in the board as it is lifted out of the drive chassis. Take care not to damage these cables and connectors. Remove six screws Carefully route cables through openings as the board is removed. Regenerative drive shown

12 12 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board 8. Remove the cable from connector XUV on the Switching Power Supply board. Remove cable at XUV Switching Power Supply board on back of Pulse Transformer board. 9. Remove the five screws from the Pulse Transformer board that secure the stand-offs connected to the Switching Power Supply board and remove the Switching Power Supply board from the back of the Pulse Transformer board. Remove screws

13 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board 13 Step 5: Configure the New Pulse Transformer Board The Pulse Transformer circuit board must be configured to match the drive size (armature output current and HP rating). The steps required to complete the configuration are different based on the revision code of the board. See either, Pulse Transformer Board FIR1-XX Rev. P and Lower below, or Pulse Transformer Board FIR1-XX Rev. Q and Higher on page 17. Pulse Transformer Board FIR1-XX Rev. P and Lower Important: This step requires a multimeter that measures resistance to thousandths of an ohm. 1. Cut and remove the appropriate sizing resistor(s) (if necessary) from the Pulse Transformer board based on the drive size. Refer to Table A or Table B in the Sizing Resistor Configuration section on page 14 for the appropriate configuration. Sizing resistors are located on the lower right corner of the Pulse Transformer circuit board. =

14 14 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board Sizing Resistor Configuration Table A and Table B below indicate the value of the designated resistor (R1 R5) when left in place on the Pulse Transformer board, or indicate Remove when the resistor should be cut off and removed from the board. in a cell in the tables below indicates that this resistor is not contained on the Pulse Transformer board for the designated drive size. Table A 230V AC Input Drives Drive Current DC AC Line Rating Code Amps Amps HP R1 R2 R3 R4 R5 7P Remove 27.4Ω Remove Remove 9P Remove Remove 39.2Ω Remove Remove 27.4Ω Remove Remove Ω Remove Remove Remove Remove Remove 39.2Ω Remove Remove 27.4Ω Remove Remove Ω 27.4Ω Remove Remove Remove 27.4Ω 39.2Ω Remove Remove Remove Remove 6.98Ω Remove Remove Remove 6.98Ω Table B 460V AC Input Drives Drive Current DC AC Line Rating Code Amps Amps HP R1 R2 R3 R4 R5 4P Ω Remove Remove Remove 6P Remove Remove 39.2Ω Remove Remove Remove 39.2Ω Remove Remove 27.4Ω Remove Remove Ω Remove Remove Remove Remove Remove 39.2Ω Remove Remove 27.4Ω Remove Remove Ω Remove 39.2Ω Remove Ω 27.4Ω Remove Remove Remove 27.4Ω 39.2Ω Remove Remove Remove Remove 6.98Ω Remove Remove Remove 6.98Ω Remove Remove Remove 6.98Ω

15 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board Connect the leads of a multimeter to pins 13 and 14 of connector XR on the Pulse Transformer circuit board (polarity is not important) and, using the TA potentiometer on the lower right corner of the Pulse Transformer circuit board, set the total resistance (RTA) to the appropriate value as indicated in Table C or Table D in the Total Resistance Values section on page 16. = XR The XR connector is located on the upper right corner of the Pulse Transformer circuit board. The TA potentiometer is located on the lower right corner of the Pulse Transformer circuit board next to the control power terminal block. Shown sealed.

16 16 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board Total Resistance Values Table C 230V AC Input Drives Set RTA Value Using Drive Current DC AC Line TA Potentiometer Rating Code Amps Amps HP (Ohms) 7P P Table D 460V AC Input Drives Set RTA Value Using Drive Current DC AC Line TA Potentiometer Rating Code Amps Amps HP (Ohms) 4P P Seal the TA potentiometer using RV (silicon). Continue with Step 6: Install the New Pulse Transformer Board and Existing Switching Power Supply Board on page 18.

17 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board 17 Drive Current Rating Code AC Line Amps HP DIP Switch S3 Pulse Transformer Board FIR1-XX Rev. Q and Higher Set DIP switches S3 and S4, located on the Pulse Transformer board (see Figure 1 on page 8 for location), to the correct settings based on the appropriate table below. Important: A blank cell below a switch in Tables E and F below indicate that the setting is OFF. Table E 230V AC Input Drives DIP Switch S4 DC Amps S3-1 S3-2 S3-3 S3-4 S3-5 S3-6 S3-7 S3-8 S4-1 S4-2 S4-3 S4-4 S4-5 S4-6 S4-7 S4-8 7P ON ON ON 9P ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Drive Current Rating Code AC Line Amps HP DIP Switch S3 Table F 460V AC Input Drives DIP Switch S4 DC Amps S3-1 S3-2 S3-3 S3-4 S3-5 S3-6 S3-7 S3-8 S4-1 S4-2 S4-3 S4-4 S4-5 S4-6 S4-7 S4-8 4P ON ON ON 6P ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON

18 18 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board Step 6: Install the New Pulse Transformer Board and Existing Switching Power Supply Board 1. Install the new Pulse Transformer board and existing Switching Power Supply board in reverse order of removal as detailed in Step 4: Remove the Pulse Transformer and Switching Power Supply Boards on page Install the new Isolation sheet (if present) before installing the Pulse Transformer and Switching Power Supply boards. ATTENTION: Failure to install the Isolation sheet below the Pulse Transformer and Switching Power Supply boards may result in damage to the drive. 3. Replace the gate lead cables with the new cables provided. ATTENTION: Each gate lead cable must be connected to the exact connector from which it was removed on the Pulse Transformer circuit board or damage to the drive may occur. 4. Inspect the existing connection cables for burn marks, cracks or loose connectors. If necessary, replace the cables connected to connector X3, X4 (for drives with a fan) and XP on the Pulse Transformer board with the new cables provided. Step 7: Install the Control EMI Shield and Control Board Install the Control EMI Shield and Control board in reverse order of removal.

19 PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board 19 Step 8: Replace the Protective Covers and Documenting the Change 1. Replace the protective covers in the reverse order of removal as described in Step 2: Remove the Protective Covers on page Install the DPI cable (if present). 3. Record the installation of the new Pulse Transformer board and date of installation on the Field Installed Option label on the side of the drive (as shown below). Related Documentation Allen-Bradley publications are available on the internet at For... Read this document Publication Number In depth information regarding the User Manual - PowerFlex Digital DC Drives 20P-UM001 operation of PowerFlex Digital DC drives

20 1S7A04 Power, Control and Information Solutions Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI USA, Tel: (1) , Fax: (1) Europe/Middle East/Africa: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) , Fax: (32) Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) , Fax: (852) Publication 20P-IN008B-EN-P - December 2009 Supersedes 20P-IN008A-EN-P - March 2009 Copyright 2009 Rockwell Automation. All rights reserved. Printed in USA.

PowerFlex DC Drive - Frame C Field SCR Module

PowerFlex DC Drive - Frame C Field SCR Module Installation Instructions PowerFlex DC Drive - Frame C Field SCR Module!!! ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should plan or implement the installation,

More information

PowerFlex 700H and 700S AC Drives Frame 9 Main Fan Capacitor Replacement Kit

PowerFlex 700H and 700S AC Drives Frame 9 Main Fan Capacitor Replacement Kit Installation Instructions PowerFlex 700H and 700S AC Drives Frame 9 Main Fan Capacitor Replacement Kit ATTENTION: This drive contains ESD (Electrostatic Discharge) sensitive parts and assemblies. Static

More information

Lifting & Mounting PowerFlex 700S and 700H Drives (Frames 10-14)

Lifting & Mounting PowerFlex 700S and 700H Drives (Frames 10-14) Installation Instructions Lifting & Mounting PowerFlex 700S and 700H s (Frames 10-14) General Precautions! TTENTION: To guard against possible personal injury and/or equipment damage Do Not allow any part

More information

FlexPak 3000 DC Drives and WebPak 3000 DC Drives Replacement Parts

FlexPak 3000 DC Drives and WebPak 3000 DC Drives Replacement Parts FlexPak 000 DC s and WebPak 000 DC s Replacement Parts Instruction Manual D-48-5 Effective Date: March, 007! ATTENTION: Only qualified electrical personnel familiar with the construction of this equipment

More information

PowerFlex 700 User Manual Update

PowerFlex 700 User Manual Update DANGER REMOTE SOURCE(S) OF POWER. DISCONNECT ALL SOURCES OF POWER BEFORE OPENING THE DOOR. ENERGY STORAGE CAPACITORS. VERIFY LOW VOLTAGE DISCHARGE BEFORE SERVICING. SEE INSTRUCTION MANUAL. Document Update

More information

1370 DC Loop Contactors and Lug Kits

1370 DC Loop Contactors and Lug Kits Installation Instructions 1370 DC Loop Contactors and Lug Kits 1370 DC Contactors are electromagnetically held contactors specially designed to switch the armature current from a DC drive module to a shunt

More information

PowerFlex 700 Drive - Frame 8 Components Replacement

PowerFlex 700 Drive - Frame 8 Components Replacement Installation Instructions PowerFlex 700 Drive - Frame 8 Components Replacement Catalog Numbers 20B Important User Information Read this document and the documents listed in the additional resources section

More information

PowerFlex 700 Drive - Frame 9 Components Replacement

PowerFlex 700 Drive - Frame 9 Components Replacement Installation Instructions PowerFlex 700 Drive - Frame 9 Components Replacement Catalog Numbers XXX XXX XXXX XXX XXX XXX Important User Information Solid-state equipment has operational characteristics

More information

Example Maintenance Schedule 1. The attached document is an example of an acceptable maintenance schedule.

Example Maintenance Schedule 1. The attached document is an example of an acceptable maintenance schedule. IRRIGATION TRAINING & RESEARCH CENTER California Polytechnic State University San Luis Obispo, CA 93407-0730 Phone: 805.756.2434 FAX: 805.756.2433 www.itrc.org Example Maintenance Schedule 1 The attached

More information

Installation Instructions. PowerFlex 700 Drive - Frame 7 Components Replacement

Installation Instructions. PowerFlex 700 Drive - Frame 7 Components Replacement Installation Instructions PowerFlex 700 Drive - Frame 7 Components Replacement Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical

More information

PowerFlex 700S and 700H Fan Inverter Upgrade Kit (Frame 10-11)

PowerFlex 700S and 700H Fan Inverter Upgrade Kit (Frame 10-11) Installation Instructions PowerFlex 700S and 700H Fan Inverter Upgrade Kit (Frame 10-11) Introduction Use this document to upgrade the fan inverters on PowerFlex 700S or 700H frame 10 or frame 11 drives.!!!!!

More information

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement Installation Instructions PowerFlex 700 Drive - Frame 8 Components Replacement Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical

More information

841XL PREMIUM EFFICIENCY MOTORS

841XL PREMIUM EFFICIENCY MOTORS 841XL PREMIUM EFFICIENCY MOTORS 8 4 1 X L A C M O T O R S D E S I G N E D T O M E E T Y O U R S E V E RE D U T Y N E E D S As an original member of the NEMA Energy Task Force, Rockwell Automation has

More information

Power Fuse Assembly Replacement (for 3000A 1395 DC Drives)

Power Fuse Assembly Replacement (for 3000A 1395 DC Drives) REPLACEMENT KIT INSTRUCTIONS Power Fuse Assembly Replacement (for 3000A 1395 DC Drives) Contents What This Kit Contains This document shows how to remove and replace a power fuse assembly (and how to replace

More information

Allen-Bradley Motors. NRU Diode Bridge Assembly Replacement ( A DC) REPLACEMENT KIT INSTRUCTIONS. Contents. What This Kit Contains

Allen-Bradley Motors. NRU Diode Bridge Assembly Replacement ( A DC) REPLACEMENT KIT INSTRUCTIONS. Contents. What This Kit Contains REPLACEMENT KIT INSTRUCTIONS NRU Diode Bridge Assembly Replacement (180-350A DC) Contents In 180A DC and 350A DC NRUs, all 6 diodes (D1 - D6) and the both the positive and negative heatsinks (HS1 - HS2)

More information

Electrically Held to Mechanically Latched Contactor

Electrically Held to Mechanically Latched Contactor Electrically Held to Mechanically Latched Contactor Bulletin 1502 Series E or later Retrofit Instructions Important User Information Read this document and the documents listed in the Additional Resources

More information

Double Pole Circuit Breaker Kit for Non-Regenerative MinPak Plus DC Drives

Double Pole Circuit Breaker Kit for Non-Regenerative MinPak Plus DC Drives Double Pole Circuit Breaker Kit for Non-Regenerative MinPak Plus DC Drives Model Numbers 14C210, 14C211, 14C212, and 14C213 Instruction Manual D2-3385! ATTENTION: Only qualified electrical personnel familiar

More information

Allen-Bradley 1397 Pulse Encoder Interface Card

Allen-Bradley 1397 Pulse Encoder Interface Card Installation Instructions IN Allen-Bradley 1397 Pulse Encoder Interface Card Cat. No. 1397-PE Table of Contents What This Option Provides........................ 1 Where This Option Is Used........................

More information

Installation, Operation And Maintenance of. AC and DC Mine Motors

Installation, Operation And Maintenance of. AC and DC Mine Motors Installation, Operation And Maintenance of AC and DC Mine Motors Instruction Manual B-3623-1 June, 2003 Table of Contents General Safety/Acceptance Instructions..2 Installation Instructions. 3 Operating

More information

Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101

Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101 Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101 Instruction Manual D2-3302-3 The information in this manual is subject to change without notice. Throughout

More information

Selection Guide. PowerFlex Digital DC Drive

Selection Guide. PowerFlex Digital DC Drive Selection Guide PowerFlex Digital DC Drive PowerFlex Digital DC Drive The PowerFlex DC drive combines powerful performance with flexible control to produce a highly functional, cost effective drive and

More information

Installation Instructions. Y-Series Brushless Servo Motor

Installation Instructions. Y-Series Brushless Servo Motor Installation Instructions Y-Series Brushless Servo Motor Catalog Number Y-1002-1, Y-1002-2, Y-1003-1, Y-1003-2, Y-2006-1, Y-2006-2, Y-2012-1, Y-2012-2, and Y-3023-2 These installation instructions describe

More information

Resistive Brake Module

Resistive Brake Module Installation Instructions Resistive Brake Module (Catalog Numbers 2090-XB33-16, 2090-XB33-32, 2090-XB120-01, 2090-XB120-03, and 2090-XB120-06 This publication provides installation instructions for the

More information

External Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s LF200405xxx, LF200460xxx, LF200520xxx, LF200608xxx

External Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s LF200405xxx, LF200460xxx, LF200520xxx, LF200608xxx External us Resistor Kit for LiquiFlo Drives Drive M/N s LF200405xxx, LF200460xxx, LF200520xxx, LF200608xxx Instruction Manual D2-3538!!!!! TTENTION: Only qualified electrical personnel familiar with the

More information

A-dec 570L Dental Light on a Non-DCS System INSTALLATION GUIDE

A-dec 570L Dental Light on a Non-DCS System INSTALLATION GUIDE A-dec 570L Dental Light on a Non-DCS System INSTALLATION GUIDE Non-DCS LED Dental Light 86.0350.00 Rev B Choose an Installation Guide The manual used to install the light depends on whether the system

More information

Battery Replacement. Installation Instructions. Summary of Changes. Catalog Number 2711P-RY2032. Original Instructions

Battery Replacement. Installation Instructions. Summary of Changes. Catalog Number 2711P-RY2032. Original Instructions Installation Instructions Original Instructions Battery Replacement Catalog Number 2711P-RY2032 Topic Page Summary of Changes 1 Important User Information 2 Precautions 3 About This Publication 2 Replace

More information

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 40-75 HP @ 230 VAC and 75-150 HP @ 460 VAC Model Numbers: 906FK1101 and 906FK1201 Instruction Manual D2-3330-2! ATTENTION:

More information

ELECRAFT KX3 Application Note

ELECRAFT KX3 Application Note ELECRAFT KX3 Application Note Installing the Speaker Grille Cloth Revision A, July 30, 2012 Copyright 2012, Elecraft, Inc., All Rights Reserved Background Some KX3 owners have reported issues with the

More information

A-dec 371L or 571L Dental Light on an A-dec 361, 362, or 363 Support Center INSTALLATION GUIDE

A-dec 371L or 571L Dental Light on an A-dec 361, 362, or 363 Support Center INSTALLATION GUIDE A-dec 37L or 57L Dental Light on an A-dec 36, 36, or 363 Support Center INSTALLATION GUIDE 37L 57L Before You Begin WARNING Failure to turn off or disconnect the power before you begin this procedure can

More information

An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT

An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT INSTRUCTION MANUAL 1. DESCRIPTION KEPCO An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT BOP 1KW-MG RETROFIT KIT 219-0562 Kepco KIT 219-0562 contains the PROMs used to upgrade the firmware for BOP

More information

PCCA POWER CONNECT CARD. DS200PCCAG1A thru DS200PCCAG10A

PCCA POWER CONNECT CARD. DS200PCCAG1A thru DS200PCCAG10A (Supersedes GEI-100161A) PCCA POWER CONNECT CARD DS200PCCAG1A thru DS200PCCAG10A These instructions do not purport to cover all details or variations in equipment, nor to provide every possible contingency

More information

VARIABLE SPEED AC MOTORS 1/3-2,500 HP INVERTER DUTY MOTORS

VARIABLE SPEED AC MOTORS 1/3-2,500 HP INVERTER DUTY MOTORS VARIABLE SPEED AC MOTORS 1/3-2,500 HP INVERTER DUTY MOTORS IN 1904, RELIANCE ELECTRIC INTRODUCED THE WORLD'S FIRST VARIABLE SPEED MOTOR. FOR OVER 96 YEARS, RELIANCE ELECTRIC MOTORS HAVE LED THE INDUSTRY

More information

PHOTOSWITCH Liquid Level and Resistance Sensing Control Bulletin 13DJ3-3000

PHOTOSWITCH Liquid Level and Resistance Sensing Control Bulletin 13DJ3-3000 Liquid Level and Resistance Sensing Control Bulletin 3DJ3-3000 Product Data Description Features The Photoswitch Bulletin is a high sensitivity Liquid Level Control designed to detect the level of conductive

More information

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control Selection Guide for SMC-Delta and SMC-3 A New Dimension in Motor Control Discover a New Dimension in Motor Control: SMC-Delta and SMC-3 The Allen-Bradley SMC-Delta and SMC-3 softstarters from Complete

More information

MP-Series Integrated Gear Motors

MP-Series Integrated Gear Motors Installation Instructions MP-Series Integrated Gear Motors (Catalog Numbers: MPG-A004-031, MPG-A004-091, MPG-A010-031, MPG-A010-091, MPG-B010-031, MPG-B010-091, MPG-A025-031, MPG-A025-091, MPG-B025-031,

More information

ST 3000 R300 Smart Meter & R300 Smart Meter with ZS Option Installation Instruction

ST 3000 R300 Smart Meter & R300 Smart Meter with ZS Option Installation Instruction ST 3000 R300 & R300 with ZS Option Installation Instruction Kit (Part Number 51205754-001, -002, -003, -004) Document Number Form: 34-ST-33-47A Effective: 10/00 Supersedes: 34-ST-33-47, dated 7/99 Summary

More information

DC Variable Speed Drive Panel

DC Variable Speed Drive Panel DC Variable Speed Drive Panel Installation, Operation & Maintenance Instruction Manual Bulletin #: CC-IOM-0103-D Manufacturers of Quality Pumps, Controls and Systems ENGINEERED PUMP OPERATIONS 2883 Brighton

More information

S4M Pulley and Gears Maintenance Kit

S4M Pulley and Gears Maintenance Kit S4M Pulley and Gears Maintenance Kit Installation Instructions This kit includes the parts and documentation necessary to install the drive system maintenance kit into the S4M. Read these instructions

More information

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) EN44 and EN88 Non-Spring Return Electronic Actuators

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) EN44 and EN88 Non-Spring Return Electronic Actuators Dodge Engineering & Controls, Inc. EA678R3 45 a b e d c a. Actuator b. Position indicator c. Mounting bracket (for dampers) d. Mounting screws e. 4 mm hex wrench Figure 1. Parts of the EN44 and EN88 Actuators.

More information

The Complete Range up to 710 kw. Overview Contactors

The Complete Range up to 710 kw. Overview Contactors The Complete Range up to 710 kw Overview Contactors Rockwell Automation Contactors - the Complet Motor rating AC-3, 400 V 2.2 kw 4.0 kw 5.5 kw 4 kw 5.5 kw 7 Rated operational current 60 C AC-3, 400 V [A]

More information

Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to VAC, 3 HP to VAC without NEMA1 Enclosures

Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to VAC, 3 HP to VAC without NEMA1 Enclosures Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to 150 HP @ 230 VAC, 3 HP to 600 HP @ 460 VAC without NEA1 Enclosures odel Numbers 912FKxxxx and 913FKxxxx Instruction anual

More information

A-dec Dental Lights on an A-dec 300 Base Mount Post INSTALLATION GUIDE

A-dec Dental Lights on an A-dec 300 Base Mount Post INSTALLATION GUIDE A-dec Dental Lights on an A-dec 300 Base Mount Post INSTALLATION GUIDE Before You Begin Turn off the power to the system before you begin the installation. DANGER Failure to turn off the power before you

More information

Altivar 61/71 Adjustable Speed Drives Spare Parts Kits

Altivar 61/71 Adjustable Speed Drives Spare Parts Kits Altivar 61/71 Adjustable Speed Drives Spare Parts Kits Instruction Bulletin 30072-452-77 Retain for future use. For Frame Size 10: ATV61HD90M3X, ATV61HC13N4, ATV71HD75M3X, ATV71HC11N4 30072-452-77 Spare

More information

External Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s 120L4060, LF151200W4

External Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s 120L4060, LF151200W4 External us Resistor Kit for LiquiFlo Drives Drive M/N s 120L4060, LF151200W4 Instruction Manual D2-3537!!!!! TTENTION: Only qualified electrical personnel familiar with the construction and operation

More information

SWX-100-INT-PCR Internal Isolation Switch

SWX-100-INT-PCR Internal Isolation Switch SWX-100-INT-PCR Internal Isolation Switch Installation and Operation Instructions INTRODUCTION The Dairyland SWX-100-INT-PCR kit consists of the SWX-100- PED pull-style isolation switch, 2/0 AWG lead assemblies

More information

10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits through -512

10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits through -512 10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits 51404974-501 through -512 Document Number Form: 62-86-33-16D Effective: 3-1-01 Supersedes: 11-00 Summary Retrofitting your 10260 actuator from

More information

Spare Allen-Bradle. Battery Replacement. Installation Instructions. About This Publication. Catalog Number 2711P-RY2032

Spare Allen-Bradle. Battery Replacement. Installation Instructions. About This Publication. Catalog Number 2711P-RY2032 Installation Instructions Battery Replacement Catalog Number 2711P-RY2032 Topic Page Important User Information 2 Precautions 3 Replace the Battery in PanelView Plus Terminals 3 Replace the Battery in

More information

Installation and Operating Manual

Installation and Operating Manual MOTORS AND DRIVES SIGNAL ISOLATOR Accessory for BC204 Regenerative Drive Installation and Operating Manual 4/2000 MN1387 TABLE OF CONTENTS Section Page i. Safety Warning..........................................................

More information

Allen-Bradley HP Inverting Fault Circuit Breaker Kit

Allen-Bradley HP Inverting Fault Circuit Breaker Kit Allen-Bradley 1397 400-600HP Inverting Fault Circuit Breaker Kit Cat. Nos. 1397-IFB600 What This Option Provides This option is intended to be applied to regenerative 1397 drives with high inertia loads.

More information

External Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s 50L4060, 50LW4060, 50LR4060, 64L4060, 64LW4060, 64LR4060, LF150500W4, LF150643W4

External Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s 50L4060, 50LW4060, 50LR4060, 64L4060, 64LW4060, 64LR4060, LF150500W4, LF150643W4 External us Resistor Kit for LiquiFlo C Drives Drive M/N s 50L4060, 50LW4060, 50LR4060, 64L4060, 64LW4060, 64LR4060, LF150500W4, LF150643W4 Instruction Manual D2-3536!!!!! TTENTION: Only qualified electrical

More information

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI 250-0287-rev2.qxd 3/12/01 10:27 AM Page a DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D-00-010-AI M/N DC3N-12D-4X-010-AI Instruction Manual D2-3452-1 250-0287-rev2.qxd

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 1794-ASB Series B) 1 9 2 3 4, 5 6 7 8 Component Identification 1 Remote I/O Adapter module 2 Indicators 3 Communication reset pushbutton (PRL) 4 Access door to switches

More information

World-Class Motion Control with Worldwide Support

World-Class Motion Control with Worldwide Support Rockwell Automation is an automation leader who not only develops innovative technology, but has the expertise and global supply network to be your complete automation solution provider. Rockwell Automation

More information

PowerFlex 6000 Medium Voltage AC Drives

PowerFlex 6000 Medium Voltage AC Drives PRELIMINARY INFORMATION PowerFlex 6000 Medium Voltage AC Drives Simple. More Reliable. Easy-to-use. User-friendly Control for Variable and Constant Torque Applications Cost-effective solutions for new

More information

LVPS Replacement Instruction Sheet

LVPS Replacement Instruction Sheet LVPS Replacement Instruction Sheet INTRODUCTION Use the following instructions when replacing the Astec Low Voltage Power Supply (LVPS) in CP2000-ZX (116-001101-03/04, 116-001113-01, 116-001124-01) or

More information

Upgrading the Boxer LAD blower module

Upgrading the Boxer LAD blower module Upgrading the Boxer LAD blower module The LAD blower module directs airflow to help cool the light engine. Christie recommends replacing the old LAD blower module that is designed with two slots with the

More information

DC3RD Digital Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC. Instruction Manual D2-3455

DC3RD Digital Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC. Instruction Manual D2-3455 DC3RD Digital Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC Instruction Manual D2-3455 The information in this manual is subject to change without notice. Throughout this manual, the following

More information

802C System Controller Original and SMD Version

802C System Controller Original and SMD Version 802C System Controller Original and SMD Version Units with serial numbers beginning with 100000 are the original 802C's. Units with serial numbers beginning with 200000 are the new SMD 802C's. 1997 Bose

More information

Abbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL

Abbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL Abbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL DESCRIPTION. The Model BD-50E is a rugged tester designed for testing tank lining and other applications where extended use is necessary.

More information

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator Table of Contents Page Introduction... 1 Description... 1 Specifications... 2 Installation... 3 Calibration... 4 General Maintenance...

More information

More power to manufacturers. Improving electric vehicle production processes

More power to manufacturers. Improving electric vehicle production processes More power to manufacturers Improving electric vehicle production processes of the automotive powertrain The continuing story of innovation in the automotive industry shows no sign of coming to an end.

More information

Replacing the T320 Cooling System Components. Replacing a T320 Fan Tray. Removing a T320 Front Fan Tray

Replacing the T320 Cooling System Components. Replacing a T320 Fan Tray. Removing a T320 Front Fan Tray Replacing the T320 Cooling System Components Replacing a T320 Fan Tray Replacing a T320 Fan Tray on page 1 Replacing a T320 Air Filter on page 5 The T320 router has two front fan trays. The front fan trays

More information

K Wiring and Electronics

K Wiring and Electronics HKBay.com K Wiring and Electronics Written By: HKBay 2017 hkbay.dozuki.com Page 1 of 12 TOOLS: Hex key; ball ended, long arm, 2.5mm (1) PARTS: Arduino Mega (blue) (1) RAMPS board (red) (1) glass tabs (3)

More information

AC Drives Regenerative Energy Solutions. Product Summary

AC Drives Regenerative Energy Solutions. Product Summary AC Drives Regenerative Energy Solutions Product Summary #% &TKXGU Regenerative Energy Solutions Snubber Resistor Braking Kits Line Regeneration Controls Synchronous Rectifier Controls AC Drives and Regenerative

More information

PowerFlex 6000 Medium Voltage Variable Frequency Drive Shipping, Handling, and Installation Manual

PowerFlex 6000 Medium Voltage Variable Frequency Drive Shipping, Handling, and Installation Manual Installation Instructions PowerFlex 6000 Medium Voltage Variable Frequency Drive Shipping, Handling, and Installation Manual Publication 6000-IN006A-EN-P Important User Information Read this document and

More information

CoolWave 2 Phase Control Board and Cable Replacement Kit

CoolWave 2 Phase Control Board and Cable Replacement Kit Instruction Sheet P/N 1102452-02 CoolWave 2 Phase Control Board and Cable Replacement Kit Use the Phase Control Board and Cable Kit to upgrade your CoolWave 2 power supply to the new configuration. NOTE:

More information

Electronic Proportional (EP) Control for Heavy Duty Series 0/1 Piston Pumps Model 33 Model 39 Model 46. Model 54 Model 64 Model 76

Electronic Proportional (EP) Control for Heavy Duty Series 0/1 Piston Pumps Model 33 Model 39 Model 46. Model 54 Model 64 Model 76 Electronic Proportional (EP) Control for Heavy Duty Series 0/1 Piston Pumps Model 33 Model 39 Model 46 Model 54 Model 64 Model 76 Table of Contents Introduction.......................................................

More information

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC Instruction Manual D2-3453 The information in this manual is subject to change without notice. Throughout this manual, the following notes

More information

Kinetix 5700 Capacitor Modules

Kinetix 5700 Capacitor Modules Installation Instructions Kinetix 5700 s Catalog Numbers 98-CAP-40, 98-CAP-DCBUS-IO Topic Page About the s Before You Begin Install the s Connector Data 6 Wiring Requirements 8 Additional Resources Summary

More information

Preventive Maintenance Checklist of Industrial Control and Drive System Equipment

Preventive Maintenance Checklist of Industrial Control and Drive System Equipment Service Bulletin Preventive Maintenance Checklist of Industrial Control and Drive System Equipment Use the following checklist as a guide in performing preventive maintenance. ATTENTION: Servicing energized

More information

PowerFlex Digital DC Drive

PowerFlex Digital DC Drive Technical Data PowerFlex Digital DC Drive Table of Contents Topic Page Additional Resources 3 Product Description 3 Standard Drives Program 4 Catalog Number Explanation 6 Standard Drives Product Selection

More information

Kinetix 350 Single-axis EtherNet/IP Servo Drives

Kinetix 350 Single-axis EtherNet/IP Servo Drives Installation Instructions Kinetix 350 Single-axis EtherNet/IP Servo Drives Catalog Numbers 2097-V31PR0-LM, 2097-V31PR2-LM, 2097-V32PR0-LM, 2097-V32PR2-LM, 2097-V32PR4-LM, 2097-V33PR1-LM, 2097-V33PR3-LM,

More information

FB1100/FB1200 Flow Computer Battery Field Replacement Guide

FB1100/FB1200 Flow Computer Battery Field Replacement Guide FB1100/FB1200 Flow Computer Battery Field Replacement Guide For Part Numbers (Kits): 399103-01-5 Battery Pack (lithium) 399186-01-8 Battery Pack (lead Acid) 399457-00-0 Battery Pack (lead acid-enersys)

More information

Direct Communication Module

Direct Communication Module Installation Instructions Direct Communication Module (Catalog Number 1747-DCM) Inside...................................... page For More Information.............................. 3 Hazardous Location

More information

Installation Data. Allen-Bradley 1336/1336VT/1336 PLUS/PLUS II/IMPACT 1336 FORCE Drives Dynamic Braking

Installation Data. Allen-Bradley 1336/1336VT/1336 PLUS/PLUS II/IMPACT 1336 FORCE Drives Dynamic Braking Installation Data Allen-Bradley 336/336VT/336 PLUS/PLUS II/IMPACT 336 FORCE Drives Dynamic Braking Series D Cat. No. 336-MOD-KA005, KB005 and KC005 Series D Cat. No. 336-MOD-KA00, KB00 and KC00 Series

More information

Drives in Common Bus Configurations with PowerFlex 755TM Bus Supplies

Drives in Common Bus Configurations with PowerFlex 755TM Bus Supplies Application Techniques Original Instructions Drives in Common Bus Configurations with PowerFlex 755TM Bus Supplies Important User Information Read this document and the documents listed in the additional

More information

Fincor Series 2230 MKII/2240

Fincor Series 2230 MKII/2240 Fincor Series 2230 MKII/ Fincor Series 2200 regenerative drives are ideal for your more demanding applications. They feature flexibility with ratings up to 5 horsepower. The Series 2230 MKII offers new

More information

ELECRAFT K3 HIGH-PERFORMANCE METER TRANSCEIVER INSTALLING CRYSTAL I.F. FILTERS. Rev A, October 15, 2007

ELECRAFT K3 HIGH-PERFORMANCE METER TRANSCEIVER INSTALLING CRYSTAL I.F. FILTERS. Rev A, October 15, 2007 ELECRAFT K3 HIGH-PERFORMANCE 160 6 METER TRANSCEIVER INSTALLING CRYSTAL I.F. FILTERS Rev A, October 15, 2007 Copyright 2007, Elecraft, Inc. All Rights Reserved Contents Introduction... 3 Customer Service

More information

N/S= Not Shown Bold = Part available for purchase. Italic = Part not available for purchase, listed and shown for reference only.

N/S= Not Shown Bold = Part available for purchase. Italic = Part not available for purchase, listed and shown for reference only. Media Rewind Upgrade Installation Instructions Prepare for Installation This kit includes the parts and documentation necessary to install the media rewind option kit into the 105SL printers. Read these

More information

PM-200 POWER SUPPLY MODULE v3.2 ASSEMBLY & INSTALLATION INSTRUCTIONS

PM-200 POWER SUPPLY MODULE v3.2 ASSEMBLY & INSTALLATION INSTRUCTIONS PM-200 POWER SUPPLY MODULE v3.2 ASSEMBLY & INSTALLATION INSTRUCTIONS WARNING: Voltages inside the amplifier CAN & WILL KILL YOU! You MUST know how to work around HIGH VOLTAGE safely. If you do not, get

More information

User's Manual O

User's Manual O 11/3/99 3535.ai User's Manual 3535 3535 O Step Motor Drivers Copyright 1998 Applied Motion Products, Inc. 404 Westridge Drive Watsonville, CA 95076 Tel (831) 761-6555 (800) 525-1609 Fax (831) 761-6544

More information

PowerFlex 755T Drive Solutions New Solutions for Low Harmonic, Regenerative & Common Bus Applications

PowerFlex 755T Drive Solutions New Solutions for Low Harmonic, Regenerative & Common Bus Applications PowerFlex 755T Drive Solutions New Solutions for Low Harmonic, Regenerative & Common Bus Applications May 2016 Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 1 Today s PowerFlex 750-Series

More information

PREHEATER. Instruction Manual

PREHEATER. Instruction Manual PREHEATER Instruction Manual Thank you for purchasing the Hakko 853. This unit preheats electronic printed wiring boards. Please read this manual before operating the Hakko 853. Keep this manual readily

More information

MV SMC-Flex OEM Components

MV SMC-Flex OEM Components MV SMC-Flex OEM Components Bulletin 1503E Installation Instructions Important User Information Read this document and the documents listed in the Additional Resources section about installation, configuration,

More information

OPERATING MANUAL TYPE HLB for ISSUE 2

OPERATING MANUAL TYPE HLB for ISSUE 2 OPERATING MANUAL for TYPE HLB60-450 ISSUE 2 0 CONTENTS INTRODUCTION...2 SAFETY CONSIDERATIONS...2 CONNECTION PROCEDURE...3 OPERATING INSTRUCTIONS...3 SPECIFICATION...4 MAINTENANCE PROCEDURES...5 FAULT

More information

160S Rewind Option Kit Installation Instructions

160S Rewind Option Kit Installation Instructions Installation Instructions GENERAL This kit includes the parts and documentation necessary to install the Media Rewind Option into the Zebra 160S printer. Read these instructions thoroughly before attempting

More information

A-dec 351 Assistant s Instrumentation on an A-dec 311/411/511 Dental Chair INSTALLATION GUIDE

A-dec 351 Assistant s Instrumentation on an A-dec 311/411/511 Dental Chair INSTALLATION GUIDE A-dec 351 Assistant s Instrumentation on an A-dec 311/411/511 Dental Chair INSTALLATION GUIDE Contents Before You Begin.......... 2 Install the Rigid Arm....... 3 Connect the Electrical Wires and Data

More information

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Made in the U.S.A. NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Nema Enclosed DC Control Specifications Catalog Number BC140 or Features BC138 BC139 BC140-FBR BC154 BC160 BCWD140

More information

CoolWave 2 Transformer T3 and Wire Harness Upgrade Kits

CoolWave 2 Transformer T3 and Wire Harness Upgrade Kits Instruction Sheet P/N 1102354A CoolWave 2 Transformer T3 and Wire Harness Upgrade Kits Two kits are available to upgrade the CoolWave 2 transformer: Transformer and Harness Kit (required for first time

More information

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317) 715B CONTROL SERIES CONTROLS Instruction Manual Line Voltage DC Brushless Motor Control LT715B (IM-715B-0100) P.O. Box 10 5000 W. 106th Street Zionsville, Indiana 46077 Phone (317) 873-5211 Fax (317) 873-1105

More information

ELECTRICAL SYSTEM UPGRADE

ELECTRICAL SYSTEM UPGRADE NEW CONTROLLER & ELECTRICAL SYSTEM UPGRADE FOR DAIRY TECH, INCORPORATED 10, 30 & 60G PASTEURIZERS Parts to Include 2 Wire ties (Nuts) 2 sticky wire mount pads Large Rubber Grommet (for bottom of electric

More information

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY 222 W. Memorial Road, Oklahoma City, OK 73114-2317 Phone: 1-800-624-7697 Fax: 405-755-8425 www.magpowr.com E-mail: magpowr@magpowr.com INSTRUCTION MANUAL MODEL PS-24 24 VDC POWER SUPPLY All of the information

More information

LED Downlight Ceiling Fixtures

LED Downlight Ceiling Fixtures ED Downlight Ceiling Fixtures Every attempt has been made to ensure that this documentation is as accurate and up-to-date as possible. However, Vertical Express assumes no liability for consequences, directly

More information

17429X.00 SERIES MODELS:

17429X.00 SERIES MODELS: LEESON ELECTRIC MOTORS, GEARMOTORS AND DRIVES R User s Manual 17429X.00 SERIES MODELS: 174298.00 174299.00 PWM REGENERATIVE DC TO DC DRIVES II Table of Contents 17429X.00 Drives...............................................................

More information

PowerFlex 7000 AC Drive with Direct-to-Drive Technology. Re-installing a Common Mode Choke Bulletin 7000 Installation Instructions

PowerFlex 7000 AC Drive with Direct-to-Drive Technology. Re-installing a Common Mode Choke Bulletin 7000 Installation Instructions PowerFlex 7000 AC Drive with Direct-to-Drive Technology Re-installing a Common Mode Choke Bulletin 7000 Installation Instructions Important User Information Solid-state equipment has operational characteristics

More information

TBX-1328 High-Accuracy Isothermal Terminal Block

TBX-1328 High-Accuracy Isothermal Terminal Block NATIONAL INSTRUMENTS The Software is the Instrument Installation Guide TBX-38 High-Accuracy Isothermal Terminal Block This guide describes how to install and use the TBX-38 high-accuracy isothermal terminal

More information

Installing the CO 2 Cryogenic Oven Cooling Kit

Installing the CO 2 Cryogenic Oven Cooling Kit Installing the CO 2 Cryogenic Oven Cooling Kit Agilent 6850 Series II Network GC System Accessory G2625B This kit contains: Description Chassis 1 Chassis Cover 1 Ship kit: 1 Cooling coil 1 Coil bracket

More information

Allen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500

Allen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500 Installation Instructions CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns Catalog Number 2500 Topic Page Important User Information 2 Location Planning 3 Environment 3 Removal

More information

505 Size 5 Series A Construction

505 Size 5 Series A Construction 505 Size 5 Series A Construction With Overload Relays Without Overload Relays Item Part Description Left-Hand Contactor Right-Hand Contactor Both Contactors No. Part Number Part Number Part Number 1 Stationary

More information

Kinetix 300 Single-axis Servo Drives

Kinetix 300 Single-axis Servo Drives Installation Instructions Kinetix 300 Single-axis Servo Drives Catalog Numbers 2097-V31PR0, 2097-V31PR2, 2097-V32PR0, 2097-V32PR2, 2097-V32PR4, 2097-V33PR1, 2097-V33PR3, 2097-V33PR5, 2097-V33PR6, 2097-V34PR3,

More information