Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $

Size: px
Start display at page:

Download "Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $"

Transcription

1 January 1 Vol. 1, ef. No. [0247] eavy uty, Fusible, - 361FK NEMA 12 Enclosure Industrial ust-tight NEMA 4 Enclosure atertight, Painted Steel Enclosure Corrosion esistant, Stainless Steel 2-Pole 40V AC 0V AC or C (Suitable for Service Entrance Use ith a Neutral or Ground ug Kit Installed) FK 262FK 263FK 264FK 265FK 266FK 267FK ,4. 3,535. 5,4. 9,5. 261FK or or 264FK or or or 3-Pole 40V AC 0V AC, 2V C (Suitable for Service Entrance Use ith a Neutral or Ground ug Kit Installed) FK 362FK 363FK 364FK 365FK 366FK 367FK ,145. 1,6. 3,05. 7,7. 11,. 365FPK 366FPK 367FPK 3-Pole 40V AC 0V AC, 2V C, NEMA 7 and 9 Enclosure 9,6. 14,6. 17, FK 362FK 363FK 364FK 365FK 366FK 367FK 1,670. 5,1. 1,7. 1,35. 3,645. 5,1. 11,9. 17,3.,1. Enclosure Corrosion esistant, Non-Metallic 361FCK 362FCK 363FCK 364FCK 2,. 3,1. 5,.,1. 4-ire (Three Blades, 3-s, ) 40V AC 0V AC, 2V C NK 362NK 363NK 364NK 365NK 366NK 4-Pole 40V AC 0V AC, 2V C 0 463FK 464FK 7.. 1,5. 1,. 4,145.,0. 1,3. 2,2. 365NPK 366NPK 9,9. 14, NK 362NK 363NK 364NK 365NK 366NK 1,745. 1,9. 3,9. 5, ,4. 17,. 361NCK 362NCK 363NCK 364NCK NEMA 12 enclosures ( amperes) can be field modified to meet NEMA 3 rainproof requirements when a factory provided drain hole is opened. Use 3-pole catalog numbers below. C rating for ampere switches is 2 volts. Contact the Safety Switch Flex Center ( ) for availability of this product. 2,. 3,2. 5,9.,290. iscount Symbol C CAT..01.T.E For more information contact Cutler-ammer at:

2 January 1 Vol. 1, ef. No. [0229] Tangential knockouts on sides, top, and bottom. Enables any size of conduit to be mounted close to the wall, providing for cable installation closer to the wall and a neat appearance. Enclosed otary Provide users with the ability to lock directly wired motor loads in the OFF position to comply with new OSA lockout/tagout regulations. Also for machine applications that require compact, economical disconnect switches. Meets NEC article 4 requirements for a separate disconnect means within sight of all motor loads. Padlockable in the OFF position (up to three padlocks) to meet OSA lockout requirements. Available in 16 ampere ratings. 0V AC, three- and four-pole non-fusible device. ated for making and breaking loads. Accepts auxiliary contacts. Capability to signal PC controllers. Ground lug connection provided. Enviroine Cutler-ammer offers a line of safety switches designed for your special application and/or extreme environmental conditions. Enviroine Stainless Steel Switch primarily for use in the meatpacking and food processing industries or any application where water is frequently used to hose down equipment. In addition to the stainless steel enclosure, the interior mechanism, back pan, and springs are stainless steel. s for these eavy uty switches are amperes, 2 0V AC, available as fusible and nonfusible switches. indow Switches These switches are available with either an upper window over the switch contacts or a lower window over the fuse block. The upper window provides visual verification of ON/OFF status. The lower window switch allows for visual verification of fuse status if used in conjunction with ittelfuse, Inc fuses with blown fuse indicator. s are - amperes, 2 0V AC, fusible and non-fusible. Available in NEMA 12/3, 4X stainless steel enclosures. eceptacle Switches These eavy uty Switches are pre-wired and interlocked to polarized receptacles for three-phase, three-wire, grounded type power plugs. These are used for portable power applications such as welders, infrared ovens, batch feeders, conveyors, truck and marine docks. eceptacles are interlocked to handle mechanisms so that power plugs may not be inserted or removed when the switch is in the ON position unless noted otherwise. s are amperes, 0V AC, NEMA 12, 4X stainless steel enclosures. Non-Metallic Switch This switch has a KYON enclosure. This is a compression molded fiberglass reinforced polyester enclosure, which is capable of withstanding almost any corrosive environment. s are amperes, 2 0V AC, fusible and non-fusible. Enclosure is rated. Features, Benefits and Functions General uty (Cartridge ) Visible double break rotary blade mechanism Side opening door on all enclosures Mechanically interlocked cover to prevent easy access when the switch is in the ON position ith Class fuses, switches may be used on systems capable of delivering,000 amperes MS symmetrical Clearly visible and accessible neutral where applicable Visible ON/OFF indication Tangential knockouts on A designs Ample wiring space ouble padlocking capability on A Triple padlocking capability on 0A Additional door locking capability Bilingual English/Spanish nameplate and door label on A eavy uty Visible double break rotary blade mechanism Mechanically interlocked cover to prevent easy access when the switch is in the ON position Clear line shield with probe holes Clearly visible palm fitting red handle Triple padlocking capability Tangential knockouts on NEMA 1 and NEMA 3 enclosures through A Built-in fuse pullers on and NEMA 12 enclosures through A Additional door locking capability Complete accessory and renewal parts data shown on inner door label A NEMA 12 designs convertible to NEMA 3 by opening factory installed drain hole Standards and Certifications U 9 U NEMA KS-1 CAT..01.T.E For more information contact Cutler-ammer at:

3 - January 1 Vol. 1, ef. No. [0236] Product Specifications Table -23. Safety Switch Selection Guide Class of Poles Enclosure s NEMA 1 NEMA 3 NEMA 12 NEMA 4 Painted Steel Stainless Steel Non-Metallic General uty eavy uty 6-Pole Motor Circuit ouble Throw otary Switches Max. 2V AC orsepower ated Max. 0V AC orsepower ated Max. 0V AC Max. 0V AC orsepower ated Fusible Plug 1 and 2 Cartridge 0 2 and 3 Non-Fusible 0 2 and 3 Fusible Cartridge 0 1 2, 3 and 4 1A NEMA 12 enclosures ( amperes) can be field modified to meet NEMA 3 rainproof requirements when a factory provided drain screw is removed. 1A A Non-Fusible -1 2, 3 and 4 A - A - A A A Fusible Cartridge 6 Non-Fusible 6 Fusible Cartridge T (0V) T (2V) 0 Non-Fusible 2, 3, 4 and 6 2 and 3 0A A A A Max. 0V AC Non-Fusible 3, 4 A A Table -24. Enviroine Safety Switch Selection Guide Enviroine Class of Poles Enclosure s NEMA 1 NEMA 3 NEMA 12 NEMA 4 Painted Steel Stainless Steel Non-Metallic Stainless Enclosure with Stainless Mechanism Viewing indow Upper and ower Fusible Cartridge 2 and 3 Non-Fusible 3 Fusible Cartridge 3 Non-Fusible 3 eceptacle Fusible Cartridge 3 Non-Fusible 3 Non-Metallic Fusible Cartridge 3 Non-Fusible 3 NEMA 12 enclosures ( amperes) can be field modified to meet NEMA 3 rainproof requirements when a factory provided drain screw is removed. For more information contact Cutler-ammer at: CAT..01.T.E

4 -12 imensions January 1 Vol. 1, ef. No. [023] imensions Table -27. eavy uty, Non-Fusible, 0V, 3-Pole, NEMA 1, 3 eight idth epth eight idth epth 0 1-7/ (3) -7/ (3) 21-11/16 (551) 27-5/ (702) 53-7/ (136) 59-3/ (1) 6 (1727) 70-5/16 (176) -1/ (6) -1/ (6) 11-1/ (23) 16 (6) 41-/32 (53) 11-1/4 (26) 12-5/ (321) 19-/16 (7) Note: imensions are for estimating purposes only. Table -2. eavy uty, Fusible, 2V and 0V, 3-Pole Solid Neutral, 0 1 Note: imensions are for estimating purposes only. 12-1/ () 12-1/ () 34-3/ (73) 57-5/ (1464) 63 () 71-3/4 (122) 70-5/16 (176) -1/ (6) -1/ (6) 11-1/ (23) 16 (6) 41-/32 (53) -1/4 (2) 11-1/2 (292) 12-5/ (321) 19-/16 (7) NEMA 1, 3 eight idth epth eight idth epth -7/ (3) -7/ (3) 21-11/16 (551) 27-5/ (702) 53-7/ (136) 59-3/ (1) 6 (1727) 70-5/16 (176) -1/ (6) -1/ (6) 11-1/ (23) 16 (6) 41-/32 (53) 11-1/4 (26) 12-5/ (321) 19-/16 (7) 17-7/ (454) 17-7/ (454) 34-3/ (73) 57-5/ (1464) 63 () 71-3/4 (122) 70-5/16 (176) -1/ (6) -1/ (6) 11-1/ (23) 16 (6) 41-/32 (53) -1/4 (2) 11-1/2 (292) 12-5/ (321) 19-/16 (7) Figure -4. NEMA 1-3 eavy uty -1 s C C Figure -5. NEMA 4, 4X and 12 eavy uty - s Table -29. eavy uty, Non-Fusible, 2V and 0V, 3-Pole, ouble Throw NEMA 1, 3 eight idth epth eight idth epth / (6) 24-5/ (6) 24-5/ (6) 37-3/ (949) 53-13/16 (1367) 63-5/16 (1) 63-5/16 (1) 11-/16 (3) 11-/16 (3) 11-/16 (3) 19-9/16 (497) 23-1/ (57) 24-1/ (613) 24-1/ (613) 9-7/ (1) 9-7/ (1) 9-7/ (1) 11-1/4 (26) 12-1/2 (31) -7/ (657) -7/ (657) -7/ (657) 41 (41) 57-1/2 (14) 12 (5) 12 (5) 12 (5) 19-1/2 (495) -1/4 (2) -1/4 (2) -1/4 (2) 11-5/ (295) 12-1/2 (31) C Note: imensions are for estimating purposes only. Table -. eavy uty, Fusible, 2V and 0V, 3-Pole, ouble Throw NEMA 1, 3 eight idth epth eight idth epth Figure -6. NEMA 1-3 ouble Throw - s / (9) 36-5/ (9) 36-5/ (9) -7/ (1292) 74-3/4 (19) 6-1/ (21) 11-/16 (3) 11-/16 (3) 11-/16 (3) 19-9/16 (497) 27-7/16 (697) 9-7/ (1) 9-7/ (1) 9-7/ (1) 11-1/4 (26) 39-13/16 (11) 39-13/16 (11) 39-13/16 (11) 55-5/ (1413) 74-3/4 (199) 12 (5) 12 (5) 12 (5) 19-9/16 (497) -1/4 (2) -1/4 (2) -1/4 (2) 11-5/ (295) Note: imensions are for estimating purposes only. Figure -7. NEMA 12-4X ouble Throw - s For more information contact Cutler-ammer at: CAT..01.T.E

5 January 1 Vol. 1, ef. No. [0241] 1/2V AC General uty, Fusible, 1/2V AC General uty, Fusible, - Specifications through 0 amperes. Suitable for service entrance applications unless otherwise noted. orsepower rated. Bolt-on hub provision. Provided for general duty switches in a NEMA 3 enclosure. See Page -5 for selection. U isted File No. E5239. Meets U 9 for enclosed switches and NEMA Std. KS-1. 0 ampere switches incorporate K-Series design. P221NGB (New design available first quarter of 1 existing design is shown.) G321NB Table /2V AC General uty, Fusible, System Provision Maximum orsepower s 1-Phase AC 3-Phase AC C 1V 2V 2V 2V NEMA 1 Enclosure Indoor NEMA 3 Enclosure ainproof Fusible Plug 2-ire (One Blade, One, ) 1V AC Plug 1/2 P111NGB ire (Two Blades, Two s, ) 1/2V AC Plug 1/2 1 2 P221NGB Use cartridge fuse catalog number G221NB Fusible Cartridge 2-Pole 2-ire (Two Blades, Two s) 2V AC 0 These switches do not have an interlock which prevents door from being opened when switch is in the ON position. Maximum hp ratings apply only when dual element fuses are used. Solid neutral bars are not included in A and 0A switches. Order separately from table on Page -4. Use 3-wire catalog numbers below. Grounded B phase rating, U listed. 3-ire (Two Blades, Two s, ) 1/2V AC 0 1-1/ /2 1-1/ / /2 7-1/ /2 7-1/2 1 G2FGK 1,6.00 G226FGK 3,20.00 G221NGB G222NGB G223NGB G224NGK G2NGK G226NGK ,.00 3,5.00 G2FK 2,15.00 G226FK 4, G221NB G222NB G223NB G224NK G2NK G226NK ,4.00 4, iscount Symbol C CAT..01.T.E For more information contact Cutler-ammer at:

6 - eavy uty, Fusible, January 1 Vol. 1, ef. No. [0246] 0V AC eavy uty, Fusible, Specifications through 1 amperes. orsepower rated through amperes. Suitable for service entrance use, except 1 ampere on 40Y/277 or 0Y/347 grounded wye systems, per NEC 2- and 2-95, and 4-pole switches. U isted File No. E5239. For factory modifications refer to Pages -6 through -9. Table -39. Fusible 277/40-0 Volts System Class Provision Maximum orsepower s with Time elay s 362NK 1-Phase AC 3-Phase AC C 40V 0V 40V 0V 2V 0V NEMA 1 Enclosure Indoor 2-Pole 40V AC 0V AC or C (Suitable for Service Entrance Use ith a Neutral or Ground ug Kit Installed) /2 261FGK 262FGK 263FGK 264FGK 265FGK 266FGK 267FGK 3-Pole 40V AC 0V AC, 2V C (Suitable for Service Entrance Use ith a Neutral or Ground ug Kit Installed) /2 3-Pole 40V AC 0V AC, 2V C, NEMA 7 and 9 Enclosure FGK 362FGK 363FGK 364FGK 365FGK 366FGK 367FGK 36FGK S361FX S362FX S363FX S364FX ,1. 2,990. 4,7. 7, ,10. 3,165. 5,50. 9,3. 11,700. 2,545. 2,795. 3,495. 6,2. NEMA 3 Enclosure ainproof 361FK 362FK 363FK 364FK 365FK 366FK 367FK 36FK ,1. 1,590. 3,790. 7,5. 11,5. 13,0. 4-ire (Three Blades, 3-s, ) 40V AC 0V AC, 2V C / Pole 40V AC 0V AC, 2V C 2-Ph 2-Ph 3-Ph 3-Ph NEMA 12 enclosures ( amperes) can be field modified to meet NEMA 3 rainproof requirements when a factory provided drain hole is opened. Use 3-pole catalog numbers below. C rating for ampere switches is 2 volts. Contact the Safety Switch Flex Center ( ) for availability of this product. 361NGK 362NGK 363NGK 364NGK 365NGK 366NGK 367NGK 36NGK 461FGK 462FGK 463FGK 464FGK 465FGK 466FGK ,3. 3,4. 5,770. 9, , ,1. 1,900. 5,.,4. 361NK 362NK 363NK 364NK 365NK 366NK 367NK 36NK ,2. 1,655. 4,0. 7,70. 12,1. 13,90. iscount Symbol C For more information contact Cutler-ammer at: CAT..01.T.E

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch . Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch Double-Throw, continued Ampere Rating Catalog Number Selection Safety Switch Catalog Number Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA X 30 N/A N/A N/A N/A

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................

More information

1.1. Switching Devices

1.1. Switching Devices . Switching Devices Six-Pole Motor Circuit Contents Description Page Product Overview......................... V2-T-2 General Duty............................. V2-T-24 Heavy-Duty..............................

More information

Safety Alert: Square D Safety Switches

Safety Alert: Square D Safety Switches Safety Alert: Square D Safety Switches Be Sure to Inspect Your Installed Units for Defects Schneider Electric has issued an offer safety alert on the Square D safety switch due to electrical shock hazard

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine eavy Industrial/ Marine Benefits builds a variety of benefits into one plug, receptacle and interlock system for your application. Safety Waterproof construction: standard neoprene O ringed interior components

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed

More information

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS DIVISION 26 ELECTRICAL SECTION 26 28 19 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install circuit breakers in switchboards, distribution panelboards, and separate enclosures for overcurrent protection

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not

More information

600V, Non-Fusible, (3-Pole, 3 Phase)

600V, Non-Fusible, (3-Pole, 3 Phase) 0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R Safety Switches Heavy Duty 240 Volt Indoor Type Outdoor Type 3R Horsepower Ratings 240V AC Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* 2 Wire 4 Wire 3 Wire System Rating

More information

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

Instructions for Installation, Operation and Maintenance of: WSRD Interlocked Receptacles 30, 60 & 100 Ampere 331114-1 INSTRUCTION SHEET Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere Read instructions carefully and with full understanding for safe

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection for low voltage distribution systems.

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001 2-22 0-225 Amperes F-Frame Cutler-Hammer January 200 Vol.,Ref. 2-2 Product Line Overview January 200 Vol., Ref. No. [0468] 2 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed

More information

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts 0.- Motor Starters & ontactors Low Voltage Lighting ontactors lectrically eld N January 00 Sheet 18 0 1 7 8 0 1 7 8 0 N-Open (L0-nclosed) 0 mpere 0 mpere Product escription Lighting ontactors are designed

More information

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

1. Division 26 Section Elevator Shunt-Trip Fused Disconnect Switches. SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,

More information

ENCLOSED DISCONNECT SWITCHES

ENCLOSED DISCONNECT SWITCHES Ferraz Shawmut Enclosed isconnect es are designed to meet customer s requirements for compact and durable individual disconnecting means. Both fusible and non-fusible versions are available in a variety

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

IN2 Enclosed Switches and Circuit Breakers

IN2 Enclosed Switches and Circuit Breakers Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Enclosed Switches and Circuit Breakers Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals

More information

Quik-Spec. Section Contents

Quik-Spec. Section Contents Section Contents Page Quik-Spec Coordination Panel Boards......... 238-239 Quik-Spec Power Module Switches and Panels.. 240-241 Quik-Spec DC Safety Switches.................. 242 Quik-Spec Solar Combiner

More information

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install Midwest Electric Products Safety Switches Rugged, reliable and easy to install Midwest Safety Switches Features Midwest Electric Products offers a wide variety of general duty and heavy duty safety switches,

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

E C N A A F -

E C N A A F - 33-52 NA ontactors & Starters 3-Phase agnetic Starters nclosed Freedom Line January 1 Vol. 2, Ref. No. [0068] Selection Table 33-102. NA Freedom Line nclosed ontrol ing System 33 esign Page N - NA 33-40

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

Product Guide. NEMA pump controls.

Product Guide. NEMA pump controls. Product Guide NEMA pump controls www.usa.siemens.com/controls Class 87 full voltage pump controller with fusible disconnect switch and standard features Class 87 NEMA full starter pump control panels Product

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame Vol. 1, Ref. No. 10499) Product Selection Table 12-56. Types 12-33 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1 Sect_0_Speedfax2007 /26/07 5:05 PM Page -1 SPEEDFAX TM 2007-2008 Safety Switches Contents Safety Switch Guide Form Specifications -2 Feature Comparison - Enclosure Types -4 Catalog Numbering System -5

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame 12-34 70 - Amperes Cutler-Hammer Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

Light Duty. General Duty. Heavy Duty. Double Throw Vdc Photovoltaic Heavy Duty Disconnect Switch. Standards:

Light Duty. General Duty. Heavy Duty. Double Throw Vdc Photovoltaic Heavy Duty Disconnect Switch. Standards: Table of Contents Section Safety Switches Light uty Fusible -2 Application ata and imensions - Standards: UL 98 Enclosed and ead Front Switches. UL Listed under File E2875. NEMA Standards Publication KS1.

More information

F-Frame. January 2001 Vol. 1, Ref. No. [0586] Discount Symbol... CB-2. For more information contact Cutler-Hammer at:

F-Frame. January 2001 Vol. 1, Ref. No. [0586] Discount Symbol... CB-2. For more information contact Cutler-Hammer at: -0 Motor ircuit Protectors Vol. 1, Ref. No. [058] -rame Table -188. V A, V NMA Starter Size ont. Amps am Motor ull Load urrent Amps MP Trip MP Table -188. V A, V (ontinued) NMA Starter Size ont. Amps am

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. - Product Selection M-Frame Cutler-Hammer Vol. 1, Ref. No. [0537] 300-800 Amperes 12-71 -" Product Selection Table 12-114. Types MDL and HMDL Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units Maximum Continuous Ampere

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES Complying with BSEN60947 and IEC 408 the RDMP range of rotary cam switches are suitable for on load switching of general distribution

More information

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview

More information

1.1. Switching Devices. Safety Switches

1.1. Switching Devices. Safety Switches . Catalog Number Eaton General Electric Siemens Square D Fusible, Three-Pole, Four-Wire, 20 Vac, NEMA 3R 30 DH32NRK TH32R HF32NR H32NRB 60 DH322NRK TH322R HF322NR H322NRB 00 DH323NRK TH323R HF323NR H323NRB

More information

BAC Custom Engineered Controls

BAC Custom Engineered Controls BAC Custom Engineered Controls Product Detail Product Introduction......................................... K2 BAC Custom Engineered Controls Benefits....................................................

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

NMC Combination Line Starters and Enclosures

NMC Combination Line Starters and Enclosures NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS Prepared by: SXZO DISCONNECT SWITCH REQUIREENTS FOR DISTRIBUTED GENERATION CUSTOERS 060559 Department: Electric Distribution Section: Design and Construction Approved by: D.Jantz (DWJ7) Date: 8/15/17 Rev.

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

General and Heavy Duty Safety Switches Accessories

General and Heavy Duty Safety Switches Accessories eneral and Heavy uty Safety es Accessies Selection HR612 HT63 HN612 lass R use lip Kits All eneral uty and Heavy uty es are field convertible to accept lass R use lip Kits. The kits prevent the installation

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles Compatible with UL 1686 C1 Pin & Sleeve Devices Safer. Easier. Better. MENNEKES Non-Metallic MSR Switched and Interlocked

More information

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous 3P Description Page No. Application/Selection 1016, 1017 Interlocked Receptacle with Disconnect Switch WSR 30, 60, 100A Aluminum 1018,

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

Transformer Disconnects

Transformer Disconnects Catalog April 05 Class 9070 CONTENTS Description..............................................Page Introduction................................................. 3 Standard Features............................................

More information

Product Selection 3-Pole Contactors

Product Selection 3-Pole Contactors - Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Section 3. Table of Contents. Safety Switches. General Duty. Light Duty. Heavy Duty. Double Throw 3-1

Section 3. Table of Contents. Safety Switches. General Duty. Light Duty. Heavy Duty. Double Throw 3-1 Table of Contents Section Safety es General uty General uty & Not -2 Application ata and imensions - Standards: UL 98 Enclosed and ead Front es. UL Listed under File E2875. NEMA Standards Publication KS1.

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations, purchased and installed by customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase 4

More information

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Enclosed Rotary Switch Product Specification Sheets Table of Contents Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX

More information

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V 804 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A07NN A Man Motor Protector Eaton Corp Catalog Number A07NN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

GHN424NW HHN426N HUN361AW

GHN424NW HHN426N HUN361AW GHN424NW HHN426N HUN61AW Passed The Test of Time All Murray safety switches have passed rigid testing requirements to assure reliable performance. In addition to tests designed and conducted during the

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase

More information

Cable-Operated Disconnect Switches. Accessories

Cable-Operated Disconnect Switches. Accessories Cable-Operated Disconnect Switches Accessories Description For Use With Auxiliary Contacts 1 N.O. Contact 1494C, 1494F, 1494V, and 1494G ( 1495-N8 1 N.O. Contact (low-level switching) A) Disconnect Switches

More information

Contents. Volume 1 Residential and Light Commercial CA E December

Contents. Volume 1 Residential and Light Commercial CA E December Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle Features 30-600A, 600VAC and DC ratings UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 15852 Visible blade quick make and break switching action Panel and Flange mounted assemblies

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION Specification Number: 26 24 13.20 Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION 26 24 13.20 SWITCHBOARDS (Long) Main Disconnect Group Mounted Fusible

More information

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection Table of Contents Introduction...2 Safety Switches...4 Symbols...6 Need for Circuit Protection...8 Fuses... 13 Fuse Ratings and Classifications... 16 Enclosures... 19 Switch Design...24 Safety Switch Ratings...29

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified. SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Powergrid Solution s Metal Enclosed Switchgear has many different customizable options and configurations. Customers

More information

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! To learn the basic differences between control, load and fusible

More information

Air Conditioning Disconnects Molded Case Switch

Air Conditioning Disconnects Molded Case Switch Air Conditioning Disconnects Molded Case Switch Catalog 3150CT0401R08/09 2009 Class 3150 QO200TR QO200TRNM CONTENTS Description............................................. Page..........................................

More information

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950. Vol. 1, Ref. No. [0559] - Amperes M-Frame 12-93 % Rated Digitrip OPTSM s with interchangeable Rating Plugs Order as individual components: Frame (which includes Trip Unit), Rating Plug, Terminals. Table

More information

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable

More information

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: 1. For commercial and industrial installation, purchased and installed by the customer. 2. To enclose 600 volt insulation class instrument transformers

More information

HCI General Purpose Disconnects

HCI General Purpose Disconnects 30 AMPERES 1oo AMPERES C General Purpose Disconnects AMPERES 0 AMPERES Quality Designed... Thoroughly Tested orsepower Rated 30-0 Amperes, 240, 480 and 0 Volts AC, 2 Volts DC with adjustable operating

More information

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Selection Guide Contents Descriptions Page General Information Features and Benefits 2-3 Product Illustrations General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Heavy Duty Safety

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38 Series 7 Motor (to 100A)...2 Series 7 Enclosed (to 100A)...14 Technical Information...18 Dimensions...22 Series 7 (to 315A)...29 Technical Information...36 Dimensions...38 Series 10 Fusible and Non-Fusible...45

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Switchboards Instant Service

Switchboards Instant Service January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 24 14 600 VOLT DRAWOUT SWITCHGEAR PART 1 - GENERAL 1.01 SECTION INCLUDES: A. Individually mounted rear-accessible low voltage switchgear ANSI rated switchgear and low voltage power circuit breakers

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com J QMB Panel boards Switchboards 200,000A. short circuit rating QMB Fusible Switches Throughout our complete line of 30-SOOA. ULiisted QMB fusible switches, we've combined timeproven Square D safety switches

More information

Type VBII Visible Blade Disconnect Switches

Type VBII Visible Blade Disconnect Switches Type VBII Visible Blade Disconnect es Product Guide Siemens Type VBII visible blade disconnect switches meet either UL98 or UL1741 requirements and can be used in either service entrance or branch circuit

More information

Safety Switches Section 4

Safety Switches Section 4 Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG... 4-5 eavy Duty, Type T...4-7 eavy Duty Stainless Steel, Type T... 4-11 Mill Duty, Type T...4-13 Double Throw Switches, Type TC, TDT...4-15

More information

Air Conditioning Disconnects

Air Conditioning Disconnects .1 Product Description............................................. 2 Application Description........................................... 2 Features, Benefits and Functions...................................

More information

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein. 16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

A/C Disconnects. Only $7.99 each In cases of (6) B222-60NF In cases of (10)

A/C Disconnects. Only $7.99 each In cases of (6) B222-60NF In cases of (10) A/C Disconnects 60 amps Non-fused. 240v A.C. Single Phase. UL Listed Three piece construction that opens up mounting and wiring areas, reduces installation time. Terminals approved for 60*C and 75*C wire.

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information