Catalog Number Description

Size: px
Start display at page:

Download "Catalog Number Description"

Transcription

1 Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy duty TU=ouble throw pole 2 2 poles Blades Switchable Poles poles 4 4 poles 6 6 poles Vac (plug fuse) Voltage Rating 2 2 Vac 6 0 Vac A 2 A 0 A 4 0 A Ampere Rating 0 A 6 0 A A 8 A Factory-installed neutral (neutrals are field-installed on most general duty, heavy duty, N and double throw safety switches). No suffix NEMA Type A NEMA Type 2K AK NEMA Type 2 (without K.O.) F NEMA Type 4X Fiberglass reinforced polyester Enclosure S NEMA Types 4, 4X, and (Type 4 stainless steel) X NEMA Type 4X Krydon Factory Modifications For dc ratings, see the latest catalog listing. R NEMA Type R RB NEMA Type R (bolt-on hub provision) SS NEMA Types 4, 4X, and (Type 6 stainless steel) CLR Class R fuse kit EI or EI2 Electrical interlock kit GL Equipment ground lugs GLC Equipment ground lug, copper only KI, KI2 or KIKI or 2 Key interlocks LK Compression lugs (800 and A only) NP Phenolic legend plate PB Push buttons, pilot lights, selector switches. Customer must provide catalog number of control device to be installed SLC Copper lugs ( 0 A) SP Special paint colors SPLO Lock-on provision V Viewing window A Appleton interlocked receptacle C Crouse-inds Arktite interlocked receptacle ubbellock interlocked receptacle 09 Schneider Electric /09

2 09 Schneider Electric 26 /09 Table 4: Accessories for Current Series eavy uty Safety Switches Catalog Number Series Electrical Interlock ( Contact) Electrical Interlocks (2 Contacts) Class R Kits Solid (Al/Cu) Solid (Cu Only) Grounding Kit (Al) Grounding Kit (Cu) Fuse Puller Receptacle Plugs 466 XFA 66AK 66S EK 02 RK RFK RK 0SNA GTK06 GTK06C 664S U26 U26AK EK EK RK RK U26S U26R U266 U266AK U266S U266R U UAK UR U268 U268AK U268R 800SN 800SN SN SN PKOGTA7 PKOGTA7 PKOGTA8 PKOGTA8 U6 U6A U6AA U6AC EIK0 EIK0 EIK02 EIK02 SN0 SN0 SN0C SN0C GTK0 GTK0 GTK0C GTK0C ACP4BC APJ48 U6AK U6F U6S U6SA EIK0 9999TC EK0 EK0 EIK TC EK02 EK02 SN0 SN0C C C GTK0 PKGTA GTK0C PKOGTC ACP4BC U6SC U6X U6RB U6A EK6 9999TC EIK0 EK TC EIK02 SN0 C SN0C GTK0 GTK0C APJ48 ACP4BC U6C U62 U62A U62AA GTK06 GTK06 GTK06 GTK06C GTK06C GTK06C APJ48 ACP4BC U62AC U62A U62AK U62F 9999TC 9999TC C GTK06 GTK06 GTK06 GTK06C GTK06C GTK06C APJ648 S278 U62S U62SA U62SC U62X EK6 EK6 EK6 9999TC EK62 EK62 EK TC C C PKGTA PKOGTC ACP4BC APJ648 U62RB U62A U62C U62 GTK06 GTK06C ACP4BC APJ648 S278 U6 U6A U6AA U6AC GTK06 GTK06 GTK06C GTK06C ACP4C APJ487 U6AK U6F U6S U6SA 9999TC TC SN 0SNC GTK06 GTK06C ACP4C U6SC U6X U6RB U6A TC TC GTK06 GTK06C APJ487 ACP4C U6C U64 U64A U64AK EK EK EK EK2 EK2 EK2 0SN 0SN 0SN 0SNC 0SNC 0SNC APJ487 U64F U64S U64RB U6 E 9999R8 EK EK 9999R9 EK2 EK2 0SN 0SN 0SNC 0SNC Continued on next page

3 28 /09 UL Listed Maximum Short Circuit Current RatingsAC Only NOTE: Consult the wiring diagram of the switch to verify the UL Listed short circuit current rating. Table : Fusible Short Circuit Current Ratings eavy uty Safety Switch UL Listed Short Circuit UL Listed Fuse Class Type Current Ratings, K ka Fusible R, J, L 0 ka On 0 V 0 A switches, 0,000 A max. on corner grounded delta when protected by Class J or R fuses. Table 6: Non-Fusible Safety Switches eavy uty Switch Rating Fuse or Circuit Safety Switch (A) Breaker Type 2 Type -Phase 2 Vac 480 Vac 0 Vac Any brand circuit breaker All, K Up to ka R,T,J.L 0 ka 0 ka 0 ka 0 6 ka ka 2 ka 0 FA 4 ka 4 ka 4 ka Non-Fusible 0 F 8 ka 8 ka 8 ka Switches 0, J 6 ka ka 2 ka 0 KA 0 LA 22 ka 22 ka 22 ka 0 MA 0 K 0 L 2 ka 2 ka 2 ka 0 M Applies to NEMA Types, R, 4X stainless, 2 switches. 2 Ampere rating of fuse or circuit breaker not to exceed switch ampere rating. All and J circuit breakers are acceptable, but will only support the noted Short Circuit Current Rating. Table 7: Terminal Lug ata (NEMA Types, R, 4, 4X,, 7, 9, 2) Rating (A) Conductors Per Phase and ire Range ire Bending Space Per NEC Table 2.6 AG/kcmil Lug ire Range AG/kcmil Optional Versa-Crimp Compression Lug Field-Installed (Al) or 4 6 (Cu) 2 2 (Al) 4 (Cu) solid or 2 or 4 (Cu) 4 2 (Cu) stranded 4 4 (Al) or 4 (Cu) 2 2 (Al) or 4 2 (Cu) 0 2 /0 (Al) or 4 /0 (Cu) 2 /0 (Al) or 4 /0 (Cu) VCEL024S (Al/Cu) 6 0 (Al/Cu) VCEL06 VCEL072 /0 7 (Al/Cu) 6 /0 7 (Al/Cu) or 0 or or and VCEL /0 0 (Al/Cu) /0 0 (Al/Cu) and VCEL /0 0 (Al/Cu) /0 0 (Al/Cu) VCEL /0 7 (Al/Cu) /0 7 (Al/Cu) 8LKE2 8 4 /0 7 (Al/Cu) /0 7 (Al/Cu) 2LKE2 8 0 A switches suitable for C or 7 C conductors. 0 A switches suitable for 7 o C conductors. 2 For NEMA Types and R only. U46AK 4 6 AG (Cu). 4 XFA 4 6 AG (Cu). 22XKA 4 AG 0 kcmil (Cu). 6 Maximum wire range is () 0 kcmil or (2) 0 kcmil Al/Cu on NEMA Type 4X Stainless and NEMA Type 2. 7 Order two PK6KN mounting kits when installing VCEL06 lugs. Only one kit is required on two-pole switches. 8 See igest 7 page, 800 and A compression lug kits for additional information. 09 Schneider Electric

4 Table 9: A eavy uty Ratings Catalog Number S A AK N NRB 22S 22A 22AK 22N 22NRB 62 62RB 62S 62A 62AK 62N 62NRB S 462AK U62 U62RB U62S U62A U62AK U462 U462S U462AK U662S U662AK Vac 2 Vac 480 Vac 0 Vac Vdc 2 Vac 480 Vac 0 Vac Series Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø 2Ø 2Ø 2Ø 2Ø 2Ø 7-/2 2 7-/ / / /2 2 7-/2 2 7-/ / / /2 7-/ Use both outer switching poles. 2 For corner grounded delta only, install neutral and use switching poles for ungrounded conductors. Standard hp rating. 4 hp maximum on a corner grounded delta system. hp maximum on a corner grounded delta system. 6 Use 7 C N.O. 4 Cu or N.O. 2 Al conductors /2 7-/2 /09 09 Schneider Electric

5 Table 2: imensions Catalog Number Series Approximate imensions / / Typical NEMA Types 4, 4X,, 2, and 2K Typical NEMA Type 4X Fiberglass Reinforced Polyester and Krydon Typical NEMA Types 7 and 9 46AK 462AK 462S 46AK 46S 464AK 464S in. mm in. mm in. mm in. mm AK AK 66S 664S U26AK,S U266AK, S UAK U268AK U6AK, A U6S U6SA U6SC U6F U6X U62A U62AK, A U62S U62SA U62SC U62F U62X U6AA U6AC U6AK, A U6S U6F U6X U64F E U64AK, A U64S, SS U6AK, S U66AK, S U67AK U68AK U46AK U46S U462AK U462S U46AK U46S U464AK U464S U46AK AK 66S 664S, RK /09 09 Schneider Electric

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D 2 N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D 2 N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................

More information

Section 3. Table of Contents. Safety Switches. General Duty. Light Duty. Heavy Duty. Double Throw 3-1

Section 3. Table of Contents. Safety Switches. General Duty. Light Duty. Heavy Duty. Double Throw 3-1 Table of Contents Section Safety es General uty General uty & Not -2 Application ata and imensions - Standards: UL 98 Enclosed and ead Front es. UL Listed under File E2875. NEMA Standards Publication KS1.

More information

Light Duty. General Duty. Heavy Duty. Double Throw Vdc Photovoltaic Heavy Duty Disconnect Switch. Standards:

Light Duty. General Duty. Heavy Duty. Double Throw Vdc Photovoltaic Heavy Duty Disconnect Switch. Standards: Table of Contents Section Safety Switches Light uty Fusible -2 Application ata and imensions - Standards: UL 98 Enclosed and ead Front Switches. UL Listed under File E2875. NEMA Standards Publication KS1.

More information

Enclosed Safety Switches

Enclosed Safety Switches Enclosed Safety Switches Catalog CT0901 09 Class CONTENTS Description............................................. Page General Duty Safety Switches.............................. Page 4 Heavy Duty Safety

More information

Safety Alert: Square D Safety Switches

Safety Alert: Square D Safety Switches Safety Alert: Square D Safety Switches Be Sure to Inspect Your Installed Units for Defects Schneider Electric has issued an offer safety alert on the Square D safety switch due to electrical shock hazard

More information

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Selection Guide Contents Descriptions Page General Information Features and Benefits 2-3 Product Illustrations General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Heavy Duty Safety

More information

1.1. Switching Devices

1.1. Switching Devices . Switching Devices Six-Pole Motor Circuit Contents Description Page Product Overview......................... V2-T-2 General Duty............................. V2-T-24 Heavy-Duty..............................

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

NMC Combination Line Starters and Enclosures

NMC Combination Line Starters and Enclosures NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings.

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings. Ratings Ferraz Shawmut Class H, K and R Fuse Blocks accommodate all Class H, K and R 250 and 600V power fuses. A choice of screw, pressure plate, box and special order stud connectors fit a wide range

More information

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

Instructions for Installation, Operation and Maintenance of: WSRD Interlocked Receptacles 30, 60 & 100 Ampere 331114-1 INSTRUCTION SHEET Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere Read instructions carefully and with full understanding for safe

More information

T CLASS T FUSE BLOCKS

T CLASS T FUSE BLOCKS Ferraz Shawmut Fuse Blocks accommodate fuses up to 600A. Insulators are either of durable, glassfilled polycarbonate (GFPC) or phenolic with verified dielectric strength in excess of 2500V. Ferraz Shawmut

More information

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures 30-600 Amperes: TG and TH 800-1200 Amperes: TC Equipment Ground Kits Ampere Rating AWG/kcmil Copper AWG/kcmil Aluminum Standard Package

More information

Spring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate

Spring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate Class H, K & R USE LOCKS 250 & 600V CLASS H, K & R USE LOCKS RATINGS: Volts: 250VAC/DC, 600VAC/DC Amps: 30A, 60A, 00A, 0A, 400A, 600A SCCR: 0kA with class H fuses; 50kA with class K fuses; 0kA with class

More information

Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $

Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $ January 1 Vol. 1, ef. No. [0247] eavy uty, Fusible, - 361FK NEMA 12 Enclosure Industrial ust-tight NEMA 4 Enclosure atertight, Painted Steel Enclosure Corrosion esistant, Stainless Steel 2-Pole 40V AC

More information

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description

More information

LO 4 TK 5 LW 7. Item 1. 5 or 6 9 T 10 J 11 FE 12 CK 13 CL 14 G 15 L or 3 17 CP 18. Item 2 SN 19. Ampere Rating

LO 4 TK 5 LW 7. Item 1. 5 or 6 9 T 10 J 11 FE 12 CK 13 CL 14 G 15 L or 3 17 CP 18. Item 2 SN 19. Ampere Rating ing Devices. Modifications Flex Center Introduction The Safety Flex Center is a special facility at the site of our Cleveland, Tennessee, plant that is dedicated to providing customized safety that meet

More information

600V, Non-Fusible, (3-Pole, 3 Phase)

600V, Non-Fusible, (3-Pole, 3 Phase) 0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

Fuseblocks. Voltage Ratings: Ampere Ratings: Leakage Current: Catalog/system number Torque Range System Number

Fuseblocks. Voltage Ratings: Ampere Ratings: Leakage Current: Catalog/system number Torque Range System Number class T FuseBlocks NEW! Smaller Design Description The new Littelfuse Class T fuse blocks offer many advantages over previous generations that are noted in the features and benets section. Of particular

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Arktite Heavy Duty Circuit Breaking Plugs and Connectors Arktite Heavy Duty Circuit Breaking Plugs and Connectors 60 A, 600 VAC/250 VDC, 50**-400 hertz Dimensions Page 968 1P Plug Connector Mating APJ Plugs Mating APR Connectors Style 1 Description Cat. # Dia.

More information

Safety Switches Section 4

Safety Switches Section 4 Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG... 4-5 eavy Duty, Type T...4-7 eavy Duty Stainless Steel, Type T... 4-11 Mill Duty, Type T...4-13 Double Throw Switches, Type TC, TDT...4-15

More information

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com AR331 30 Amp Pin & Sleeve Recpt 3-W 3-P 250VDC/600vac Cooper Crouse-Hinds Catalog Number

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch . Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas 1P Arktite Heavy Duty Circuit Breaking s and s Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically operated

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Section 4. Safety Switches.

Section 4. Safety Switches. Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG...4-5 eavy Duty, Type T...4-7 eavy Duty Stainless Steel, Type T...4-11 Mill Duty, Type T...4-13 Double Throw Switches, Type TC, TDT...4-15

More information

For Options, Modifications and Accessories, see pages Discount Schedule A6

For Options, Modifications and Accessories, see pages Discount Schedule A6 Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F

More information

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous 3P Description Page No. Application/Selection 1016, 1017 Interlocked Receptacle with Disconnect Switch WSR 30, 60, 100A Aluminum 1018,

More information

D-2. Powertite Series Pin and Sleeve Receptacles, Plugs, and Cable Connectors

D-2. Powertite Series Pin and Sleeve Receptacles, Plugs, and Cable Connectors -2 Classified by UL for use in specific combinations with Crouse-Hinds Arktite. Powertite Series Pin and Sleeve Receptacles, Plugs, and Cable Connectors Applications esigned to supply power to portable

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles 1P Arktite Heavy Duty Circuit Breaking s and Receptacles Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically

More information

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed Arktite Circuit Breaking CPS Application: CPS receptacles, angle and straight types, and CPP plugs are used: with portable electrically operated devices such as motor-generator sets, compressors, conveyors,

More information

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................

More information

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 ARL2042 Receptacle Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Descriptions

More information

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1 Sect_0_Speedfax2007 /26/07 5:05 PM Page -1 SPEEDFAX TM 2007-2008 Safety Switches Contents Safety Switch Guide Form Specifications -2 Feature Comparison - Enclosure Types -4 Catalog Numbering System -5

More information

Single Socket and Horizontal Metering

Single Socket and Horizontal Metering G nergy onnections Single Socket and orizontal Metering T Approved Single Socket Metering T Approved Application Information G s Single Socket Metering products are designed for residential use. They are

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Quik-Spec. Section Contents

Quik-Spec. Section Contents Section Contents Page Quik-Spec Coordination Panel Boards......... 238-239 Quik-Spec Power Module Switches and Panels.. 240-241 Quik-Spec DC Safety Switches.................. 242 Quik-Spec Solar Combiner

More information

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC) 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC) Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Solar Combiner Solutions

Solar Combiner Solutions Solar Combiner Solutions Providing combiners and disconnects that offer superior resistance and durability from harsh weather and abusive solar environments Solar Technology Leading the way in Solar Technology

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for

More information

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 APJ10487 100 Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac Cooper Crouse-Hinds Catalog Number Manufacturer Description

More information

Solar Combiner Solutions

Solar Combiner Solutions Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from

More information

PANELBOARDS SECTION 1

PANELBOARDS SECTION 1 SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A Conformity to standards (1) Changeover switches svr-ul_14_b_1_cat > EC 6947-3 > UL98, Guide WHTY, file 1138 > UL18, Guide WPYV, file 31792 > CSA 22.2#4, Class 4651-2 (1) Product reference on request. svr_136_a_2_cat

More information

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940 Well-Guard Control Pumping Plant Panels Catalog 8940CT9701R11/15 2016 Class 8940 IRRIGATION OIL PRODUCTION CONTENTS Selection.............................................. Page 3 Factory Modifications.....................................

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles ENR Value Series Dead Front Interlocked Circuit Breaking s Cl. I, Div. & 2, roups B, C, D Cl. II, Div. & 2, roups F, Cl. III, 7BCD, 9F, 2 Dust-Ignitionproof Raintight et Locations ENP Plugs Applications:

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 00A 30A 00A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

Selection and application guide

Selection and application guide Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure

More information

Section 4. Safety Switches.

Section 4. Safety Switches. Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG... 4-5 eavy Duty, Type T...4-7 eavy Duty Stainless Steel, Type T... 4-11 Mill Duty, Type T...4-13 Double Throw Switches, Type TC, TDT...4-15

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch Double-Throw, continued Ampere Rating Catalog Number Selection Safety Switch Catalog Number Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA X 30 N/A N/A N/A N/A

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles P Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Just the right switch for your application

Just the right switch for your application Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality

More information

Switches. Safety and Disconnect Switches. Heavy Duty Safety Switch Standards and Ratings

Switches. Safety and Disconnect Switches. Heavy Duty Safety Switch Standards and Ratings Safety and Disconnect es Contents Pages Heavy Duty Safety es Safety Features........................18/2 Selection, 240V Fusible........................18/3 Selection, 600V Fusible........................18/4

More information

GHN424NW HHN426N HUN361AW

GHN424NW HHN426N HUN361AW GHN424NW HHN426N HUN61AW Passed The Test of Time All Murray safety switches have passed rigid testing requirements to assure reliable performance. In addition to tests designed and conducted during the

More information

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Enclosed Rotary Switch Product Specification Sheets Table of Contents Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX

More information

LFJ602003C 200A 600V Fus Block

LFJ602003C 200A 600V Fus Block 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LFJ602003C 200A 600V Fus Block Littelfuse Catalog Number Manufacturer Description Weight per unit Product Category Descriptions

More information

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable

More information

D-2. Powertite Series Pin and Sleeve Receptacles, Plugs, and Cable Connectors

D-2. Powertite Series Pin and Sleeve Receptacles, Plugs, and Cable Connectors -2 Classified by UL for use in specific combinations with Crouse-Hinds Arktite. Powertite Series Pin and Sleeve Receptacles, Plugs, and Cable Connectors Applications esigned to supply power to portable

More information

Laser Service Factory-assembled Panelboards

Laser Service Factory-assembled Panelboards Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page

More information

Standard Materials Bodies and covers: copper-free aluminum.

Standard Materials Bodies and covers: copper-free aluminum. -26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically operated devices

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

General and Heavy Duty Safety Switches

General and Heavy Duty Safety Switches General and Heavy Duty Safety es Accessories 10/01/13 Selection 4 Class R Fuse Clip Kits All General Duty and Heavy Duty es are field convertible to accept Class R Fuse Clip Kits. The kits prevent the

More information

CLASS J 600 Volt Fuse Blocks

CLASS J 600 Volt Fuse Blocks CLASS J 600 Volt Fuse Blocks Mersen Class J fuse blocks accommodate all Class J fuses. A choice of screw, pressure plate, box and special order stud connectors it a wide range of stranded or solid copper

More information

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous Description Page No. Application/Selection see pages 1260 1261 Arktite Delayed Action Circuit Breaking Technical Data see pages 1262 126 20

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Operation and Maintenance manual. fusible shunt trip switch

Operation and Maintenance manual. fusible shunt trip switch Operation and Maintenance manual fusible shunt trip switch Table of Contents Fusible Shunt Trip Switch Device Overview... 2 Installation Instructions... 3 Catalog Number Selection Table... 4 Motor Fuse

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions .1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design

More information

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

1. Division 26 Section Elevator Shunt-Trip Fused Disconnect Switches. SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,

More information

General and Heavy Duty Safety Switches Accessories

General and Heavy Duty Safety Switches Accessories eneral and Heavy uty Safety es Accessies Selection HR612 HT63 HN612 lass R use lip Kits All eneral uty and Heavy uty es are field convertible to accept lass R use lip Kits. The kits prevent the installation

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

Type VBII Visible Blade Disconnect Switches

Type VBII Visible Blade Disconnect Switches Type VBII Visible Blade Disconnect es Product Guide Siemens Type VBII visible blade disconnect switches meet either UL98 or UL1741 requirements and can be used in either service entrance or branch circuit

More information

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC) 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC) Appleton/Oz Gedney Catalog Number ACP1034CD Manufacturer Appleton/Oz Gedney

More information

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.

More information