Safety Switches Section 4

Size: px
Start display at page:

Download "Safety Switches Section 4"

Transcription

1 Quick Selection Guide, Enclosure Types General Duty, Type TG eavy Duty, Type T eavy Duty Stainless Steel, Type T Mill Duty, Type T Double Throw Switches, Type TC, TDT Emergency Power Transfer Switches, Type TC Double Throw Switches Service Equipment Ratings Manual Motor Starters AC Disconnects Accessories: EMA Type 1 and 3R Enclosures Accessories: EMA Type 4/4X, 12 and Mill Duty Enclosures Additional Accessories Enclosure and Knockout s through 4-38 Rev. 1/19 go.abb/industrial GE Products BuyLog 4-1

2 Quick Selection Guide General Duty Safety Switch Short Circuit Ratings UL Listed Fusing Maximum System Voltage Ampere Rating Class Withstand Ratings (rms Sym Amps) Enclosure Type Fusible K 10, Vac , Vdc 3R R 1 100,000 on-fusible: withstand ratings apply to non-fused switches when protected by an upstream fuse as listed o upstream 10,000 protection 240 Vac K upstream 10, Vdc 3R upstream 10,000 R upstream 100,000 eavy Duty Safety Switch Short Circuit Ratings Maximum System Voltage Ampere Rating Fusible Class UL Listed Fusing Withstand Ratings (rms Sym Amps) Enclosure Type 10, Vac R 200,000 3R /4X 600 Vdc J 200, L 2 100, on-fusible: withstand ratings apply to non-fused switches when protected by an upstream fuse as listed 600 Vac 600 Vdc o upstream protection upstream 10,000 R upstream 200,000 J upstream 200,000 L upstream 100,000 10, R 4/4X 5 12 TG4322 Double Throw Safety Switch Short Circuit Ratings UL Listed Fusing Maximum System Voltage Ampere Rating Class Withstand Ratings (rms Sym Amps) Enclosure Type Fusible 600 Vac R 100,000 1 J 100,000 3R T 100,000 4X L 100,000 on-fusible: withstand ratings apply to non-fused switches when protected by an upstream fuse as listed 600 Vac o upstream protection 10,000 R upstream 100,000 J upstream 100,000 T upstream 100,000 L upstream 100, R 4X T3361SS 1 Class R fuse is not available for 400A or 600A General Duty switches. 2 Class L fuses are only applicable when used with 800 and 1200A Type TC safety switches. 3 Unless otherwise noted on the enclosure TC10323R TDT GE Products BuyLog go.abb/industrial Rev. 1/19

3 Quick Selection Guide Enclosure Types Type 1 Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dirt. Type 3R Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, and snow; and that will be undamaged by the external formation of ice on the enclosure Type 4 Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, and hose-directed water; and that will be undamaged by the external formation of ice on the enclosure. Type 4X Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, hose-directed water, and corrosion; and that will be undamaged by the external formation of ice on the enclosure. Type 5 Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against settling airborne dust, lint, fibers, and flyings; and to provide a degree of protection against dripping and light splashing of liquids. Type 12 Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, and flyings; and to provide a degree of protection against dripping and light splashing of liquids. Application ote: For applications of disconnecting means in motor circuit applications, disconnect must be sized based on ampacity per EC , but not less than 115% of Motor ame-plate current. Comparison of Specific Applications of Enclosures for Indoor onhazardous Locations Type of Enclosure Provides a Degree of Protection Against the Following Environmental Conditions 1* 4 4X 5 12 Incidental contact with the enclosed equipment X X X X X Falling dirt X X X X X Falling liquids and light splashing X X X X Circulating dust, lint, fibers, and flyings** X X X Settling airborne dust, lint, fibers, and flyings** X X X X osedown and splashing water X X Oil and coolant seepage X Corrosive agents X *These enclosures may be ventilated. ** These fibers and flyings are nonhazardous materials and are not considered Class III type ignitable fibers or combustible flyings. For Class III type ignitable fibers or combustible flyings see the ational Electrical Code, Article 500. Applications of Enclosures for Outdoor onhazardous Locations Type of Enclosure Provides a Degree of Protection Against the Following Environmental Conditions 3R* 4 4X Incidental contact with the enclosed equipment X X X Rain, snow, and sleet** X X X Windblown dust, lint, fibers, and flyings X X osedown X X Corrosive agents X * These enclosures may be ventilated. ** External operating mechanisms are not required to be operable when the enclosure is ice covered. Rev. 1/19 go.abb/industrial GE Products BuyLog 4-3

4 Quick Selection Guide Product umber Structure GE Identification T R DC Duty Level = eavy Duty G= General Duty C= on-fusible Double Throw 1 D= Fusible Double Throw Fusing = on-fusible T= Fusible Double Throw Blank= d umber of Wires 2, 3, 4, 6 umber of Poles 2, 3, A and 1200A non-double throw safety switches also use the C nomenclature Ampere Rating 1= 30A 2= 60A 3= 100A 4= 200A 5= 400A 6= 600A 7= 800A 8= 1200A Maximum Voltage 2= 240V, 6= 600V Other Features B= Bottom Feed (240V, T, Type 1, A) CL= Copper Lug DC= Max DC Voltage 600V F= Farm Switch W= Viewing Window Option VRED= Red Paint Enclosure Type Blank= EMA 1 R= EMA 3R SS= EMA 4/4X Stainless Steel Type 304 SS316= EMA 4/4X Stainless Steel Type 316 SSW= Stainless Steel with Viewing Window J= EMA 5/12 M= Mill Duty EMA 12 ote: This information is provided for interpreting numbers. It should not be used to build product numbers. Accessories and Lug Sizes: See pages 2-25 to 2-30 Outlines, s and Knockouts: See pages 2-31 to GE Products BuyLog go.abb/industrial Rev. 1/19

5 General Duty, Type TG Amperes 240 Volts AC 250 Volts DC Type TG Switches Designed for residential or light commercial applications where duty is not severe amps 240Vac / 250Vdc maximum in fusible or non-fusible units EMA Type 1 (indoor) or EMA Type 3R (outdoor) enclosures Direct-drive, quick-make, quick-break mechanism snaps contacts open and closed providing positive O/OFF indication Self-leveling, three-point mounting system Integral cover interlock Visible confirmation of plated blade contact positions Spring reinforced fuse clips assure reliable contact for cool operation. Suitable for Class, K, J or R fuses, where applicable. UL Listed short-circuit rating is 10,000 rms symmetrical amps standard With Class R fuses and fuse kits installed, amp switches have UL Listed short circuit rating of 100,000 rms symmetrical amps UL Listed as service entrance equipment when installed in accordance with the ational Electric Code Safety Switches Fusible, Two-pole, 120/240 and 240 Volts AC; 250 Volts DC; Three-wire solid neutral, 240 Volts AC Fusible, Four-wire solid neutral, 208/120 and 240 Volts AC All GE General Duty safety switches carry the following certifications: UL Listed and cul Listed (UL98 Enclosed Switches/CSA-C22.2 o. 4-04) Federal Specification WS-865C EMA Enclosed Safety Switch KS Seismic Certified o, Two-pole, 240 Volts AC; 250 Volts DC ( amps only); Three-pole, 240 Volts AC or Two-pole with Switching eutral Rev. 1/19 go.abb/industrial GE Products BuyLog 4-5

6 General Duty, Type TG Spec-Setter Safey Switches Amperes 240 Volts AC 250 Volts DC General Duty Safety Switches Amperage Rating Product umber orsepower Rating DC p eutral Kit Insulated, EMA Type 1 EMA Type 3 Single-Phase 240 Vac Three-Phase 240 Vac 250 Vdc Groundable and Indoor Outdoor Bondable Fusible / 2 Pole / 3 Wire / 240V / 50/60 z 30 TG3221 TG3221R TG3222 TG3222R TG3223 TG3223R TG TG3224R TG3225 1,2 TG3225R TG3226 1,2 TG3226R 2 Fusible / 3 Pole / 4 Wire /240V / 50/60 z 30 TG4321 TG4321R TG4322 TG4322R TG4323 TG4323R TG TG4324R TG4325 1, TG4326 1, Factory Installed Factory Installed Amperage Rating Product umber orsepower Rating DC p eutral Kit Insulated, EMA Type 1 EMA Type 3 Single-Phase Three-Phase 250 Vdc Groundable and Indoor Outdoor 240 Vac Bondable on-fusible / 3 Pole / 3 Wire / 240V / 50 /60 z 30 TG3321 TG3321R TI21 60 TG TG3322R TG TG3323R TG TG3324R TIA TG3325 1, TI65 or TI65A 600 TG3326 1, TI66 For Type 3R Enclosure: amp devices have removable closing cap. Order hubs for these devices separately on page Larger amp devices require field cut openings and customer-supplied hub. General Duty safety switches are not suitable for use as service equipment in Canada. Use eavy Duty safety switches. 1 Add "B" suffix for factory reversed bottom feed. (e.g., TG3224B.) UL Listed. 2 Single make single break mechanism 3 ot suitable for use as service equipment. Solid neutral not available. 4 EMA Type 3R Fusible or on-fusible versions, ampere rating, available in heavy duty, type T models. See pages 4-8 to General Duty Red Safety Switches EMA Type 1 Amperage Rating Indoor Fusible / 2 Pole / 3 Wire / 240V / 50/60 z (Painted Red) Product umber orsepower Rating DC p EMA Type 3R Outdoor Single-Phase 240 Vac Three-Phase 480 Vac 250 Vdc Wire Size Cu Al eutral Kit Insulated, Groundable and Bondable 30 TG3221VRED Factory Installed Fusible / 3 Pole / 4 Wire / 240V / 50/60 z (Painted Red) 30 TG4321VRED TG4322VRED Factory Installed Accessories and Lug Sizes: See pages 2-25 to 2-30 Outlines, s and Knockouts: See pages 2-31 to GE Products BuyLog go.abb/industrial Rev. 1/19

7 eavy Duty, Type T Amperes 240 Volts AC 250 Volts DC Type T Switches Designed for commercial and industrial applications where safety, high performance and continuity of service are essential amps 600Vac maximum, 600Vdc maximum in fusible or non-fusible units EMA Type 1 (indoor), Type 3R (outdoor), Type 4/4X (water and dust-tight, corrosion resistant) or Type 5/12 (drip and dust-tight) enclosures Donut handle ideal for hook stick operation and accepts 3 padlocks in the OFF position Direct-drive, quick-make, quick-break mechanism snaps contacts open and closed providing positive O/OFF indication Self-leveling, three-point mounting system Coin-proof, defeatable interlock Clear line shield installed on all eavy Duty amp, 600V, all enclosure types Visible confirmation of plated blade contact positions Spring reinforced fuse clips assure reliable contact for cool operation. Suitable for Class, K, J or R fuses, where applicable. With Class R fuses or J fuses, amp switches have UL Listed short circuit rating of 200,000 rms symmetrical amps Switches rated amps use Class L fuses and have a UL Listed short circuit rating of 100,00 rms symmetrical amps UL Listed as service entrance equipment when installed in accordance with the ational Electric Code All GE eavy Duty safety switches carry the following certifications: UL Listed and cul Listed (UL98 Enclosed Switches/CSA-C22.2 o. 4-04) Federal Specification WS-865C EMA Enclosed Safety Switch KS Seismic Certified Fusible, Two-pole, 240 Volts AC; 250 Volts DC and Fusible Two-pole, 600 Volts DC, (2 poles in series for 600 Vdc) Fusible, Three-pole, Three-wire solid neutral, 120/240 and 240 Volts AC Fusible, Three-pole, 240 Volts AC 480, 480Y/277 and 600 Volts AC-250 Volts DC Fusible, Four-wire solid neutral, 208/120 and 240 Volts AC on-fusible, Two-pole, 600 Volts DC on-fusible, Three-pole, 480 and 600 Volts AC-250 Volts DC or Two-pole with switching neutral Rev. 1/19 go.abb/industrial GE Products BuyLog 4-7

8 eavy Duty, Type T Amperes 240 Volts AC 250 Volts DC eavy Duty Safety Switches Amperage Rating EMA Type 1 Indoor Product umber orsepower Rating DC p EMA Type 3R Single-Phase 240 Vac Three-Phase 240 Vac 250 Vdc Outdoor EMA Type 5, 12 Fusible / 2 Pole / 3 Wire / 240V / 50/60 z (eutral factory installed) 30 T3221 T3221R T3221J T3222 T3222R T3222J T3223 T3223R T3223J T3224 1,2 T3224R 2 T3224J T3225 1,2 T3225R 2 T3225J T3226 1,2 T3226R 2 T3226J TC ,6,7 TC72267R 3,6, TC ,6,7 TC72268R 3,6,7 Amperage Rating EMA Type 1 Indoor Product umber orsepower Rating DC p EMA Type 3R Single-Phase 240 Vac Three-Phase 240 Vac 250 Vdc Outdoor EMA Type 5, 12 Fusible / 3 Pole / 3 Wire / 240V / 50/60 z 30 T3321J T3322J T T3325R T T3326R Fusible / 3 Pole / 4 Wire / 240V / 50/60 z (eutral factory installed) 30 T4321 T4321R T4321J T4322 T4322R T4322J T4323 T4323R T4323J T4324 1,2 T4324R 2 T4324J T4325 1,2 T3325R 5,8 T4325J T4326 1,2 T3326R 5,9 T4326J eavy Duty Safety Switches 6-Pole Amperage Rating Product umber orsepower Rating DC p EMA Type 1, 3R, 5, 12 Indoor/Outdoor Single-Phase 240 Vac Three-Phase 240 Vac 250 Vdc Fusible / 6 Pole / 6 Wire / 240V / 50/60 z 30 T T T T Type 1 Enclosure: Amp devices available factory reversed for bottom feed. Add "B" suffix. 2 For switches CSA Certified for service entrance, add C suffix. 3 For switches suitable for service entrance applications in Canada, order T3267C, T3267RC, T3268C and T3268RC. 4 Available with Viewing Window. Add "W" suffix. 5 For switches suitable for service entrance applications in Canada, order T4325RC and T4326RC. 6 Rated 600 Vac only. Accepts Class L fuses only. Type D electrical performance does not apply. 7 3 wire with neutral kit ordered separately. For 800A use TI67; for 1200A use TI68A. 8 4 wire with neutral kit ordered separately. For 400A use TI65 or TI65A. 9 4 wire with neutral kit ordered separately. For 600A use TI66. ote: Many eavy Duty Switches are available with a Stainless Steel enclosure. See page Accessories and Lug Sizes: See pages 2-25 to 2-30 Outlines, s and Knockouts: See pages 2-31 to GE Products BuyLog go.abb/industrial Rev. 1/19

9 eavy Duty, Type T Amperes 600 Volts AC 600 Volts DC eavy Duty Safety Switches Amperage Rating Product umber orsepower Rating DC p EMA Type 1 Indoor EMA Type 3R Outdoor Fusible / 2 Pole / 2 Wire / 600V / 50/60 z 800 TC ,2,7 TC72267R 1,2, TC ,2,7,8 TC72268R 1,2,7,8 Three-Phase 240 Vac Single-Phase 480 Vac Three-Phase 480 Vac Single-Phase 600 Vac Three-Phase 600 Vac 125 Vdc 250 Vdc Fusible / 3 Pole / 3 Wire / 600V / 50/60 z T3361 T3361R 30 T3361RF 5 T3361RF T3362 T3362R T3362RF T3363 T3363R T T3364R T T3365R T T3366R TC ,4 TC72367R TC ,4,8 TC72368R 4,8 Fusible / 3 Pole / 4 Wire / 600V / 50/60 z (eutral factory installed) 30 T4361 T4361R T4362 T4362R T4363 T4363R T4364 T4364R Fusible / 3 Pole / 4 Wire / 600V / 50/60 z CSA Certified for service entrance (eutral factory installed) 200 T4364C T4364RC T4365C T4365RC T4366C T4366RC T4367C T4367RC 1200 T4368C T4368RC Amperage Rating Product umber orsepower Rating DC p EMA EMA Three-Phase 240 Vac Single-Phase 480 Vac Three-Phase 480 Vac Single-Phase 600 Vac Three-Phase 600 Vac 125 Vdc 250 Vdc Type 5, 12 Indoor Type 3R, 5, 12 Outdoor Fusible / 3 Pole / 3 Wire / 600V / 50/60 z 30 T3361J 6 T3361JR T3362J 6 T3362JR T3363J 6 T3363JR T3364J 6 T3364JR T3365J T3365JR T3366J T3366JR eavy Duty Safety Switches 6-Pole Amperage Rating Product umber orsepower Rating DC p Single-Phase 480 Vac Three-Phase 480 Vac Single-Phase 600 Vac Three-Phase 600 Vac 250 Vdc EMA Type 1, 3R, 5, 12 Indoor/Outdoor Fusible / 6 Pole / 6 Wire / 600V / 50/60 z 30 T T T T wire with neutral kit ordered separately. For 800A use TI67; for 1200A use TI68A. 2 Rated 600 Vac only. Accepts Class L fuses only. Type D electrical performance does not apply. 3 Type 1 Enclosure: Amp devices available, factory reversed for bottom feed. Add B suffix. 4 4 wire with neutral kit ordered separately. For 800A use TI67; for 1200A use TI68A. 5 Farm Switch with oversize Type 3R enclosure with vertical hinge. See page 4-30 for dimensions. 6 Available with Viewing Window. Add W suffix. 7 For switches suitable for service entrance applications in Canada, order T3267C, T3267RC, T3268C and T3268RC. 8 Suitable for use as service entrance equipment except on 1200A solidly grounded wye systems per EC Rev. 1/19 go.abb/industrial GE Products BuyLog 4-9

10 eavy Duty, Type T Amperes 240, 480, 600 Volts AC 600 Volts DC eavy Duty Safety Switches Amperage Rating Product umber orsepower Rating DC p EMA EMA EMA Single-Phase Three-Phase Single-Phase Three-Phase Single-Phase Three-Phase 250 Vdc Type 1 Indoor Type 3R Outdoor Type 5, Vac 480 Vac 600 Vac on-fusible / 3 Pole / 3 Wire / 240V / 50/60 z 30 T on-fusible / 3 Pole / 3 Wire / 600V / 50/60 z 30 T3361RF 4 T T3361R T3361J 2,3 T3361RF2 4 T T3362R T3362J 2,3 T3362RF T T3363R T3363J 2, T3364 1,2 T3364R T3364J T T3365R T3365J T T3366R T3366J TC TC eavy Duty Safety Switches 6-Pole on-fusible / 6 Pole / 6 Wire / 600V / 50/60 z 30 T T T T Type 1 Enclosure: Amp devices available factory reversed for bottom feed. Add "B" suffix. 2 Available with Copper Lug. Add "CL" suffix 3 Available with Viewing Window. Add "W" suffix. 4 Farm switch with oversize Type 3R enclosure and vertical hinge. See page 4-30 for dimensions. 5 Suitable for use as service entrance equipment except on 1200A solidly grounded wye systems per EC DC Rated eavy Duty Safety Switches Amperage Rating Product umber EMA EMA Type 1 Indoor Type 3R Outdoor EMA Type 5, 12 DC orsepower Ratings 125 Vdc 250 Vdc 600 Vdc Fusible / 2 Pole / 2 Wire / 600Vdc / 50/60 z 30 T2261DC T2261RDC T2261JDC T2262DC T2262RDC T2262JDC T2263DC T2263RDC T2263JDC on-fusible / 2 Pole / 2 Wire / 600Vdc / 50/60 z 30 T2261DC T2261RDC T2261JDC T2262DC T2262RDC T2262JDC T2263DC T2263RDC T2263JDC Interlocked Receptacle Switches Amperage Rating Product umber EMA Type 5, 12 Indoor EMA Type 4/4X Receptacle Manufacturer Mating Receptable orsepower Rating Fusible / 3 Pole / 3 Wire / 600V / 50/60 z 60 T3362JC T3362JCSS Crouse inds Arktite #APJ6485 For horsepower ratings, see switch without "C" or CSS suffix. on-fusible / 3 Pole / 3 Wire / 600V / 50/60 z 60 T3362JC T3362JCSS Crouse inds Arktite #APJ6485 For horsepower ratings, see switch without "C" or CSS suffix. Accessories and Lug Sizes: See pages 2-25 to 2-30 Outlines, s and Knockouts: See pages 2-31 to GE Products BuyLog go.abb/industrial Rev. 1/19

11 eavy Duty Stainless Steel, Type T Amperes 240, 600 Volts AC 600 Volts DC eavy Duty Stainless Steel, Type T Designed for commercial and industrial applications in corrosive environments where safety, high performance and continuity of service are essential amps 600 Vac maximum, 600 Vdc maximum in fusible or non-fusible units, indoor or outdoor enclosures Donut handle ideal for hook stick operation and accepts 3 padlocks in the OFF position Three or four welded mounting brackets Spring reinforced fuse clips assure reliable contact for cool operation. Suitable for Class, K, J or R fuses. The conductor rating is 60/75 C Short circuit ratings are UL Listed to 200,000 rms symmetrical amps when Class J or R fuses are installed orsepower ratings are to UL Listed maximums UL Listed as service entrance equipment when installed in accordance with the ational Electric Code We offer two types of EMA 4X enclosures: Grade 304 Stainless Steel (order product numbers with SS suffix) EMA Type 4X Grade 304 Stainless Steel elps protects against falling dirt, rain, sleet, snow, windblown dust, splashing water, hose-directed water and corrosion Applications in harsh environments such as food and beverage, coastal, mining Grade 316 Stainless Steel (order product numbers with SS316 suffix) EMA Type 4X 316 Stainless Steel, Water and Dust-tight Chemical composition that makes it more resistant to general corrosion and pitting/crevice corrosion than 304 Stainless Steel igher creep, stress-to-rupture and tensile strength at elevated temperatures than 304 Stainless Steel Excellent resistance to reducing acids and similar media Provides enhanced protection over 304 Stainless Steel in environments with salts and chemicals Applications in extremely harsh environments such as water/waste water, marine Fusible, Two-pole, Three-wire solid neutral, 240 Volts AC, 250 Volts DC Fusible, Three-pole, Three-wire, 600 Volts AC Fusible, Three-pole, Four-wire solid neutral, 240 Volts AC on-fusible, Three-pole, Three-wire, or Two-pole with switching neutral, 600 Volts AC Fusible, Two-pole, Two-wire, 600 Volts DC on-fusible, Two-pole, Two-wire, 600 Volts DC All GE eavy Duty Stainless Steel safety switches carry the following certifications: UL Listed and cul Listed (UL98 Enclosed Switches/CSA-C22.2 o. 4-04) Federal Specification WS-865C EMA Enclosed Safety Switch KS Seismic Certified Rev. 1/19 go.abb/industrial GE Products BuyLog 4-11

12 eavy Duty Stainless Steel, Type T Amperes 240, 600 Volts AC 600 Volts DC EMA Type 4X Enclosure Grade 304 Stainless Steel (see footnote below for 316 Stainless Steel offering) Amperage Product umber orsepower Ratings DC orsepower Ratings Single-Phase 240 Vac Three-Phase 240 Vac 250 Vdc Fusible / 2 Pole / 2 Wire / 240V / 50/60 z 30 T2221SS 1, T2222SS 1, Fusible / 2 Pole / 3 Wire / 240V / 50/60 z (eutral factory installed) 30 T3221SS 1, T3222SS 1, T3223SS 1, T3224SS 1, T3225SS T3226SS Fusible / 3 Pole / 3 Wire / 240V / 50/60 z 30 T3321SS 1, T3322SS 1, Fusible / 3 Pole / 4 Wire / 240V / 50/60 z (eutral factory installed) 30 T4321SS 1, T4322SS 1, T4323SS 1, T4324SS 1, T4325SS T4326SS Amperage Product umber orsepower Ratings DC orsepower Ratings Three-Phase 240 Vac Single-Phase 480 Vac Three-Phase 480 Vac Single-Phase 600 Vac Three-Phase 600 Vac 125 Vdc 250 Vdc Std Std Std Std Std Std Std Fusible / 3 Pole / 3 Wire / 600V / 50/60 z 30 T3361SS 1,2, T3362SS 1,2, T3363SS 1,2, T3364SS 1,2, T3365SS T3366SS on-fusible / 3 Pole / 3 Wire / 600V / 50/60 z 30 T3361SS 1,2,3, T3362SS 1,2,3, T3363SS 1,2, T3364SS 1,2,3, T3365SS T3366SS DC Rated eavy Duty Stainless Steel Safety Switches Amperage Product umber DC orsepower Ratings 125 Vdc 250 Vdc 600 Vdc Fusible / 2 Pole / 2 Wire / 600Vdc / 50/60 z 30 T2261SSDC T2262SSDC T2263SSDC on-fusible / 2 Pole / 2 Wire / 600Vdc / 50/60 z 30 T2261SSDC T2262SSDC T2263SSDC For switches manufactured in the USA, add BA suffix. 2 Available with Viewing Window - add W suffix 3 Available with Copper Lugs - add CL suffix 4 Available in EMA Type 4X Enclosure Grade 316 Stainless Steel - add 316 suffix. Selected Double Throw safety switches available in stainless steel. Refer to page ote: See page 4-2 for Short Circuit Ratings and page 4-22 for Lug Wire Sizes Line and Load Terminals. Accessories and Lug Sizes: See pages 2-25 to 2-30 Outlines, s and Knockouts: See pages 2-31 to GE Products BuyLog go.abb/industrial Rev. 1/19

13 Safety Switches Mill Duty, Type T Amperes 240, 480, 600 Volts AC 250, 600 Volts DC Section 4 Mill Duty, Type T Switches Designed for mill, foundry and industrial applications where safety, high performance and continuity of service are required amps 600Vac maximum, 600Vdc maximum in fusible or non-fusible units EMA Type 4/4X Grade 304 Stainless Steel (hose directed, splashing and falling liquids, dust, lint, fibers, coolants, metal filings) EMA Type 12 (dust, lint, fibers, coolants, metal filings and other non-corrosive contaminants) enclosures Donut handle ideal for hook stick operation and accepts 3 padlocks in the OFF position Manual interlock defeat knob permits contact inspection when switch is in the OFF position Three or four point mounting brackets Spring reinforced fuse clips assure reliable contact for cool operation. Suitable for Class, K, J or R fuses, where applicable. Equipment ground lugs provided. Lugs approved for both copper and aluminum wire; 60/75 C rated tang lugs are field convertible to compression (crimp) connectors Short circuit ratings are UL Listed to 200,000 rms symmetrical amps when Class J or R fuses are installed UL Listed as service entrance equipment when installed in accordance with the ational Electric Code Fusible, Two-pole, 240 Volts AC Volts DC Fusible, Three-pole, 240 Volts AC, Fusible Fusible, Two-pole, 240 Volts AC; 250 Volts DC and Fusible, Two-pole, 600 Volts DC (2 poles in series for 600 Vdc) All GE Mill Duty safety switches carry the following certifications: UL Listed and cul Listed (UL98 Enclosed Switches/CSA-C22.2 o. 4-04) Federal Specification WS-865C EMA Enclosed Safety Switch KS Seismic Certified Fusible, Three-pole, 480 and 600 Volts AC Volts DC on-fusible, Two-pole, 600 Volts DC on-fusible, Three-pole, 480 and 600 Volts AC Volts DC Rev. 1/19 go.abb/industrial GE Products BuyLog 4-13

14 Mill Duty, Type T Amperes 240, 480, 600 Volts AC 250, 600 Volts DC Mill Duty Safety Switches Amperage Rating Product umber 2 orsepower Rating DC orsepower Rating EMA Type 4X Grade 304 Single-Phase 240 Vac Three-Phase 240 Vac 250 Vdc EMA Type 12 Stainless Steel Fusible / 2 Pole / 2 Wire / 240V / 50/60 z 30 T2221M T2221MSS T2222M T2222MSS T2223M T2223MSS T2224M T2224MSS Fusible / 3 Pole / 3 Wire / 240V / 50/60 z 30 T3321M T3321MSS T3322M 1 T3322MSS T3323M T3323MSS T3324M T3324MSS T3325M T3325MSS T3326M T3326MSS Amperage Rating Product umber 2 orsepower Rating DC orsepower Rating EMA Type 4X Three-Phase 240 Vac Single-Phase 480 Vac Three-Phase 480 Vac Single-Phase 600 Vac Three-Phase 600 Vac 125 Vdc 250 Vdc EMA Type 12 Grade 304 Stainless Steel Fusible / 3 Pole / 3 Wire / 600V / 50/60 z 30 T3361M 1 T3361MSS T3362M T3362MSS T3363M T3363MSS T3364M T3364MSS T3365M T3365MSS T3366M T3366MSS on-fusible / 3 Pole / 3 Wire / 600V / 50/60 z 30 T3361M T3361MSS T3362M 1 T3362MSS T3363M T3363MSS T3364M T3364MSS T3365M T3365MSS T3366M T3366MSS DC Rated Mill Duty Safety Switches Amperage Rating Product umber 2 EMA Type 12 orsepower Rating 125 Vdc 250 Vdc 600 Vdc Fusible / 2 Pole / 2 Wire / 600Vdc / 50/60 z 30 T2261MDC T2262MDC T2263MDC on-fusible / 2 Pole / 2 Wire / 600Vdc / 50/60 z 30 T2261MDC T2262MDC T2263MDC Available with Viewing Window - add W suffix. 2 All Mill Duty switches accept neutral and auxiliary contact kits. Order from page 4-22 and Type T Interrupting and Withstand Ratings Ampere Rating Interrupting Rating Amps 3 Symmetrical 600 volts AC, 3-phase Clearing 4 (I 2 t x 10 3 ) 30A A A A 3,400 2, A 10,000 6, A 10,000 12,000 3 Maximum current at rated voltage that switch will interrupt three times without assistance from an external device. 4 Peak let-through energy for withstandability and circuit closing tests. Lug Wire Sizes Line and Load Terminals Ampere Rating Wire Range AWG/kcmil Copper Wire Range AWG/kcmil Aluminum 30A (240V) A (600V) A A 14-1/0 12-1/0 200A A (1) or (2) 1/ A (2) Accessories and Lug Sizes: See pages 2-25 to 2-30 Outlines, s and Knockouts: See pages 2-31 to GE Products BuyLog go.abb/industrial Rev. 1/19

15 Double Throw Switches Type TC, Type TDT 240, 480, 600 Volts AC 250 Volts DC on-d Double Throw Type TC Fusible Double Throw Type TDT Designed for application where safety, high performance, and continuity of service are required ighly visible O/OFF label Bright red handle Self-leveling three point mounting pattern Lockable three position (O-OFF-O) handle Lockable cover latch 60 C and 75 C conductor ratings Quick-make, quick-break mechanisms amps Use of common fuses in stacked design amps; fewer fuses required and reduced enclosure size Our Double Throw safety switches meet the following standards: UL Listed and cul Listed (UL98 Enclosed Switches/CSA-C22.2 o. 4-04) Federal Specification W-S-865C EMA Enclosed Switch KS Seismic Certified TC35322, Type TC Indoor Double Throw Switch TDT3362, Type TDT Indoor Double Throw Switch on-fusible, Three-pole, Three-wire, 240 Volts AC, 250 Volts DC O OFF O O OFF O on-fusible, Three-pole, Three-wire, 600 Volts AC, 250 Volts DC Fusible / 3 Pole / 3 Wire / Two Sources / One Load Fusible / 3 Pole / 3 Wire / One Source / Two Loads on-fusible, Three-wire solid neutral, 120/240 Volts AC on-fusible, Four-wire solid neutral, 240 Volts AC Rev. 1/19 go.abb/industrial GE Products BuyLog 4-15

16 Double Throw Switches Type TC, Type TDT 240, 480, 600 Volts AC 250 Volts DC Fusible Amperage Rating EMA Type 1 Indoor Product umber EMA Type 3R Outdoor orsepower Rating Single-Phase Three-Phase DC orsepower Rating 120 Vac 240 Vac 120 Vac 240 Vac 480 Vac 600 Vac 125 Vdc 250 Vdc Std Std Std Std Std Std Std Std Fusible / 3 Pole / 3 Wire / 240V 30 TDT3321 TDT3321R TDT3322 TDT3322R TDT TDT3323R TDT TDT3324R TDT TDT3325R TDT3326 3,4 TDT3326R 3, TDT3327 3,4 TDT3327R 3, TDT TDT3328R 4 Amperage Rating EMA Type 1 Indoor Product umber orsepower Rating DC orsepower Single-Phase Three-Phase Rating EMA Type 120 Vac 240 Vac 480 Vac 600 Vac 120 Vac 240 Vac 480 Vac 600 Vac 125 Vdc 250 Vdc EMA Type 4X Stainless Std Std Std Std Std Std Std Std Std 3R Outdoor Steel Fusible / 3 Pole / 3 Wire / 600V 30 TDT3361 TDT3361R TDT3361SS TDT TDT3362R 1 TDT3362SS TDT TDT3363R 1 TDT3363SS TDT TDT3364R 1 TDT3364SS TDT TDT3365R 2 TDT3365SS TDT3366 3,4 TDT3366R 3, TDT3367 3,4 TDT3367R 3, TDT3368 4,5 TDT3368R 4,5 1 Class J fuse option available when load base is moved Amp at 600V switches available with Class T fuse provision only. 3 Field convertible to Class T. 4 Stacked design requiring only one set of fuses (Class L). 5 Suitable for use as service entrance equipment except on 1200A solidly grounded wye systems per EC on-fusible Amperage Rating EMA Type 1 Indoor Product umber orsepower Rating DC orsepower Rating Lug Wire Sizes Line and Load Terminals EMA EMA Type 4X Three-Phase Type 3R Stainless Outdoor Steel 240 Vac 480 Vac 600 Vac 125 Vdc 250 Vdc AWG/kcmil on-fusible / 3 Pole / 3 Wire / 240V / 50/60 z 30 TC35321 TC35321R (Cu) 60 TC35322 TC35322R (Cu) 100 TC35323 TC35323R /0 (Cu) 200 TC35324 TC35324R (Cu) 400 TC35325 TC35325R 30 (2) 1/0-250 (Cu) or (Cu) 600 TC (2) 3/0-350 (Cu) or (Cu) TC35326R (2) (2) 500 (Cu/Al) 800 TC TC35327R (3) (3) 500 (Cu/Al) 1200 TC35328 TC35328R (4) 1/0 - (4) 750 (Cu/Al) on-fusible / 3 Pole / 3 Wire / 600V / 50/60 z 30 TC35361 TC35361R TC35361SS (Cu/Al) 60 TC35362 TC35362R (Cu) TC35362SS (Cu/Al) 100 TC35363 TC35363R /0 (Cu) TC35363SS /0 (Cu/Al) 200 TC35364 TC35364R (Cu) TC35364SS (Cu/Al) 400 TC ,2,3 (2) 1/0-250 (Cu) or (Cu) TC35365R TC35365SS (2) 1/0 - (2) 300 (Cu/Al) or 5 (1) 1/0-750 (Cu/Al) 600 TC ,2 (2) 3/0-350 (Cu) or (Cu) TC35366R TC35366SS (2) (2) 500 (Cu/Al) 800 TC TC35367R 4 TC35367SS (3) (3) 500 (Cu/Al) 1200 TC TC35368R 6 (4) 1/0 - (4) 750 (Cu/Al) 1 ot UL, cul or CSA Listed. 2 ot suitable for use as service equipment per EC Article o provision for auxiliary contact kit 4 Available with factory installed neutral. Add suffix. For example: TC Single barrel lug that accepts one or two cables per phase. 6 Suitable for use as service entrance equipment except on 1200A solidly grounded wye systems per EC Accessories and Lug Sizes: See pages 2-25 to 2-30 Outlines, s and Knockouts: See pages 2-31 to GE Products BuyLog go.abb/industrial Rev. 1/19

17 Double Throw Switches Type TC, Type TDT 240, 480, 600 Volts AC 250 Volts DC Type TC Accessories Amperage Rating EMA Type 1 Indoor Product umber EMA Type 3R Outdoor EMA Type 4X Grade 304 Stainless Steel eutral Kit Ground Kit 1 ormally Open 1 ormally Closed Aux Contact 2 ormally Open 2 ormally Closed Control Pole on-fusible / 3 Pole / 3 Wire / 240V 30 TC35321 TC35321R 60 TC35322 TC35322R TK100 TGL1 100 TC35323 TC35323R TK100 TG3 200 TC35324 TC35324R TK200 TG3 TAUXDT 400 TC35325 TC35325R TK400 TGL6 600 TC35326 TGL6 TC35326R DT600K DS16CP 800 TC35327 TC35327R 1 DT800K DS468GK DS200EK1 DS200EK2 DS16CP 1200 TC35328 TC35328R DT1200K on-fusible / 3 Pole / 3 Wire / 600V 30 TC35361 TC35361R TC35361SS DT100K DS100GK DS200EK1 DS200EK2 DS16CP 60 TC35362 TC35362R TK100 TGL1 TAUXDT TC35362SS DT100K DS100GK DS200EK1 DS200EK2 DS16CP 100 TC35363 TC35363R TK100 TG3 TAUXDT TC35363SS DT100K DS100GK DS200EK1 DS200EK2 DS16CP 200 TC35364 TC35364R TK200 TG3 TAUXDT TC35364SS DT200K DS200GK DS200EK1 DS200EK2 DS16CP 400 TC35365 TK400 TGL6 TAUXDT TC35365R TC35365SS DT400K DS468GK DS200EK1 DS200EK2 DS16CP 600 TC35366 TGL6 TC35366R TC35366SS DT600K DS16CP 800 TC35367 TC35367R 1 TC35367SS DT800K DS468GK DS200EK1 DS200EK2 DS16CP 1200 TC35368 TC35368R DT1200K 1 Order same accessories for the "" version. Type TDT Accessories Voltage 240V 600V Amps Product umber EMA Type 1 Indoor EMA Type 3R Outdoor EMA Type 4X Stainless Steel eutral Kit Ground Kit Class "R" Adapter Kit 30 TDT3321 TDT3321R DS12FK 60 TDT3322 TDT3322R DT100K DS100GK DS16FK 100 TDT3323 TDT3323R DS36FK "T" Adapter Kit 1200 TDT3368 TDT3368R DT1200K L move up 2 Kits come with 1 pole - must order 3 for 3-pole switch 3 Kits come with 6 poles "J" Adapter Kit 200 TDT3324 TDT3324R DT200K DS200GK DS46FK move up 400 TDT3325 TDT3325R DT400K DS468GK DS56FK DS526TK TDT3326 TDT3326R DT600K J DT626TK TDT3327 TDT3327R DT800K DS468GK L DT726TK TDT3328 TDT3328R DT1200K L move up 30 TDT3361 TDT3361R TDT3361SS DS16FK 60 TDT3362 TDT3362R TDT3361SS DT100K DS100GK DS26FK 100 TDT3363 TDT3363R TDT3361SS DS36FK 200 TDT3364 TDT3364R TDT3361SS DT200K DS200GK DS46FK move up 400 TDT3365 TDT3365R TDT3361SS DT400K DS468GK T DT400JK TDT3366 TDT3366R DT600K J DT666TK TDT3367 TDT3367R DT800K DS468GK L DS766TK 2 1 ormally Open 1 ormally Closed DS200EK1 DS200EK1 Aux Contact 2 ormally Open 2 ormally Closed DS200EK2 DS200EK2 Control Pole DS16CP DS16CP Rev. 1/19 go.abb/industrial GE Products BuyLog 4-17

18 Emergency Power Transfer Switches, Type TC Type TC Outdoor Emergency Power Transfer Switches Designed for residential or light commercial applications where duty is not severe Suitable for use as service entrance equipment when installed in accordance with ational Electrical Code Wide range of interchangeable rain-tight conduit hubs available Plated copper current-carrying parts increase longevity and performance Bonding strap can be used to ground neutral for service entrance applications Positive make and break is provided by fiber loop straps between knife blade contacts and one piece operating yoke Lockable three-position (O-OFF-O) handle Galvanized steel enclosure with drip shield 60 C and 75 C conductor ratings ot quick-make, quick-break TC10323R, Type TC Outdoor Emergency Power Transfer Switch All GE Emergency Power Transfer Switches carry the following certifications: UL Listed and cul Listed (UL98 Enclosed Switches/CSA-C22.2 o. 4-04) Federal Specification WS-865C EMA Enclosed Safety Switch KS Seismic Certified Emergency Power Transfer Switches on-fusible / 2 Pole / 3 Wire / 120/240V / 50/60z on-fusible / 3 Pole / 4 Wire / 240V / 50/60z Amperage Rating Product umber EMA Type 3 Outdoor 100 TC10323R 200 TC10324R 200 TC10424R Accessories and Lug Sizes: See pages 2-25 to 2-30 Outlines, s and Knockouts: See pages 2-31 to GE Products BuyLog go.abb/industrial Rev. 1/19

19 Double Throw Switches Service Equipment Ratings and Class Chart on-fusible Switches Fusible Switches Max Voltage Amp Product o. Suitable for use as Service Equipment Product o. Suitable for use as Service Equipment When used with a neutral, the following ratings also apply: Std Class Optional Kit 120/ A TC10323R Yes 200A TC10324R 30A TC35321 Yes 1 TDT3321 TC35321R TDT3321R R - DS12FK 3P 60A TC /240 VAC Yes 1 TDT3322 with DT100K 125/250 VDC TC35322R TDT3322R 4 Wire S/ R - DS16FK 3P 100A TC35323 Yes 1 TDT3323 TC35323R TDT3323R R - DS36FK 3P 200A TC10424R 120/240 VAC Yes 1 R - DS46FK 3P TC35324 TDT3324 with DT200K 125/250 VDC J - move up TC35324R TDT3324R 4 Wire S/ 240 TC A Yes 1 TDT3325 TC35325R TDT3325R R - DS56FK 3P TC35326 o TDT A 120/240 VAC J T - DT626TK 1P TC35326R with DS468GK TDT3326R with DS800K 125/250 VDC TC35327 with DT800BK TDT Wire S/ 800A TC35327 Yes (neutral inc.) TC35327R with DT800BK TDT3327R L T - DT726TK 1P TC35327R Yes (neutral inc.) 1200A TC35328 TDT /240 VAC Yes with DT1200K TC35328R TDT3328R 4 Wire S/ L T - move up TC35361 TDT A TC35361R with DT100K or DT100BK TDT3361R R - DS16FK 3P TC35361SS TDT3361SS TC35362 TDT A TC35362R Yes 1 277/480 VAC TDT3362R with DT100K 4 Wire S/ R - DS26FK 3P TC35362SS with DT100K or DT100BK TDT3362SS TC35363 TDT3363 Yes 1 100A TC35363R TDT3363R R - DS36FK 3P TC35363SS with DT100K TDT3363SS 200A TC35364 Yes 1 TDT /240 VAC R - DS46FK 3P TC35364R TDT3324R with DT200K 125/250 VDC J - move up TC35364SS with DT200K or DT200BK 4 Wire S/ 600 TC35365 Yes TDT A TC35365R with DT400K TDT3365R T J - DT400JK 6P TC35365SS or DT400BK TDT3365SS TC35366 o TDT A TC35366R with DT600K or DT600BK TDT3366R J T - DT666TK 1P TC35366SS with DS468GK with DS800K 277/480 VAC 4 Wire S/ TC35367 with DT800BK TDT3367 TC35367 Yes 800A TC35367R with DT800BK TDT3367R L T - DS766TK 1P TC35367R Yes TC35367SS with DS468GK 1200A TC35368 with DT1200K 2 TDT3368 TC35368R TDT3368R with DT1200K 2 L T - move up 1 ot in Canada 2 120/208V AC; 4 Wire S/ up to 600V AC; 3 Wire w/ <150V to ground 277/480V AC; for continuous industrial process or where neutral is not solidly grounded or source intended for fire pump Rev. 1/19 go.abb/industrial GE Products BuyLog 4-19

20 Definite Purpose Manual Motor Starters UL Listed. Toggle operated tumbler. Copper wire only, AWG. o overload protection. Package = 50 pcs/carton. Switch Only (no enclosure) Type 1 Indoor Enclosure o. of Ampere System P P P P Product Product Poles Rating 1 Voltage 110 Vac 240 Vac 480 Vac 600 Vac umber umber 2 30A 240Vac TC2228S TC A 240Vac 3 20A 480Vac 3 7 1/ TC2368S TC A 600Vac 1 2-Pole manual motor starters do not have a general duty rating at 480 Vac or 600 Vac Manual motor starters are not rated for Tungsten or DC lamp loads TC2368S, Manual Motor Starter 4-20 GE Products BuyLog go.abb/industrial Rev. 1/19

21 AC Disconnects Air Conditioner Disconnects Puller or on-automatic Type UL and cul Listed Fusible UL869 Service Equipment o fuse UL1429 Enclosed Pull-out Switch LISTED BO DED EUT. Fusible on-automatic EQ UIP G RO UD o Steel Disconnects 3R Outdoor Enclosure Type Volts Fusing Amps P Rating Product o. Package Pullout 240V Fusible 30 3 TF30R TF60R on-fusible TF60R on-automatic 240V on-fusible TA60R1 1 1Device does not have removable closing cap. 6 TF30R TF60R TF60R TA60R1 Plastic Disconnects 3R Outdoor Enclosure Type Volts Fusing Amps P Rating Product o. Package Fusible 30 3 TPF30R Pullout 240V TPF60R TP60R on-fusible TP60R1 1 on-automatic 240V on-fusible TPA60R1 1 1Device does not have removable closing cap. 6 TPF30R TPF60R TP60R TP60R1 Steel Disconnects 3R Outdoor Enclosure with Ground Fault Receptacle Type Volts Fusing Amps P Rating Product o. Package Pullout 240V on-fusible TF60RGFR 2 6 on-automatic TA60RGFR 2 2These disconnects include a GFCI outlet TF60RGFR Wire Range Table Copper Aluminum Connector Solid Stranded Solid Stranded Line Load eutral Equipment Ground s (inches) Product o. eight (A) Width (B) Depth (C) TF30R TF60R TF60R TF60RGFR TA60R TA60RGFR TPF30R TPF60R TP60R TP60R TPA60R A B C Rev. 1/19 go.abb/industrial GE Products BuyLog 4-21

22 Accessories: EMA Type 1 and 3R Enclosures Amperes: TG and T Amperes: TC (Single Throw Only) Equipment Ground Kits Ampere Rating 30A 60A 100A 200A 400A 600A Product umber Wire Range AWG/kcmil Copper Wire Range AWG/kcmil Aluminum Std. Pkg TGL1 (4) 14-8, (3) 14-4 (4) 12-8, (3) TG3 (3) 10-1/0 (3) 10-1/0 1 TGL6 (3) (3) TGL1 Equipment Ground Kit eutral Kit Insulated, Groundable and Bondable Ampere Rating Product umber System Voltage Fusible/on- Fusible Wire Range AWG/kcmil Copper Wire Range AWG/kcmil Aluminum 30A TI21 240Vac Either A TI Vac Either A TI Vac on-fusible A TIA62 600Vac Fusible A TI Vac on-fusible 10-1/0 10-1/0 100A TIA63 600Vac Fusible 10-1/0 10-1/0 200A TIA64 600Vac Either A TI65 Either (1) or (2) 1/0-250 (1) or (2) 1/ A TI65A Either (1) (1) Vac or 600A TI66 Either (2) (2) Vac 800A TI67 2 Either (3) or (6) 1/0-250 (3) or (6) 1/ A TI68A 2 Either (4) 3/0-800 (4) 3/0-800 Switching eutral: Order standard switch of required number of poles and use dummy fuse in neutral pole. 1 ot suitable for type TG switches. 2 ot suitable for type TC Double Throw or TC Single Throw on-fusible TG3 Equipment Ground Kit ote: All accessories are available in standard package of 1 unless otherwise noted. Lug Wire Sizes Line and Load Terminals Ampere Rating Wire Range AWG/kcmil Copper Wire Range AWG/kcmil Aluminum 30A (250V) A (600V) A A 10-1/0 10-1/0 200A A (1) or (2) 1/0-250 (1) or (2) 1/ A (2) (2) A (3) or (6) 1/0-250 (3) or (6) 1/ A (4) 3/0-800 (4) 3/0-800 TIA64 eutral Kit Insulated, Groundable and Bondable 4-22 GE Products BuyLog go.abb/industrial Rev. 1/19

23 Accessories: EMA Type 1 and 3R Enclosures Amperes: T Auxiliary Contact Kits Auxiliary contacts designed to open before switch blades. UL Listed for field installation. Product number listed is for field installed kit. Ampere Rating o. of Poles Contacts Contact Ratings Product umber 30A 30A 60A 100A 200A 400A 600A 30A 60A 100A DPDT SPDT DPDT DPDT 6 DPDT 200A 6 DPDT 10A, 125/250Vac 0.30A, 125Vdc 0.15A, 250Vdc 15A, 600Vac 0.50A, 125Vdc 0.25A, 250Vdc 15A, 600Vac 0.50A, 125Vdc 0.25A, 250Vdc 15A, 600Vac 0.50A, 125Vdc 0.25A, 250Vdc 15A, 600Vac 0.50A, 125Vdc 0.25A, 250Vdc 15A, 600Vac 0.50A, 125Vdc 0.25A, 250Vdc TAUX21D TAUX61S TAUX64D TAUX66D TAUX66D TAUX66D2 TAUX21D Contact Pilot Duty Ratings Volt Kits Inrush Current AC DC (Resistive) Volts.C.O. Break ormal Current Volts Break ormal Current TAUX61S Semidust-tight Door Gasket Kits Types T Indoor, TG and T Outdoor Switches. Product umber listed is for field mounted kit. Ampere Rating 30A 60A 100A 200A 400A 600A Product umber TG106 TG107 TG108 TAUX64D TAUX66D Rev. 1/19 go.abb/industrial GE Products BuyLog 4-23

24 Accessories: EMA Type 4/4X, 12 and Mill Duty Enclosures Amperes: T Lug Wire Sizes Line and Load Terminals Ampere Rating Wire Range AWG/kcmil Copper Factory Installed Field Installed Crimp Lugs (see table on page 4-25) Wire Range Wire Range Wire Range AWG/kcmil Aluminum AWG/kcmil Copper AWG/kcmil Aluminum 30A (250V) A (600V) A A 14-1/0 12-1/0 6-1/0 6-2/0 200A / A (1) or (2) 1/0-250 (2) or (1) 750 (2) or (1) A (2) (2) or (1) 750 (2) or (1) 750 Equipment Ground Terminals are factory installed Two lugs supplied per switch, provision for one additional lug. Factory Installed Field Installed Crimp Lugs (See table on page 4-25) Switch Ampere Rating Copper Aluminum Copper Aluminum 30A A A A A 14-1/0 14-1/ A 14-2/0 14-2/0 1 2/0 Auxiliary Contact Kits Auxiliary contacts designed to open before switch blades. UL Listed for field installation. Product number listed is for field installed kit. For Auxiliary Contact Kits, see page Optional Copper Lug eutrals Ampere Rating Fusible Lug Wire Size, AWG/kcmil, Cu Only Product umber 30A-60A o 14-2 TIJA62CL eutral Kit Insulated, Groundable and Bondable Ampere Rating Product umber System Voltage Fusible/on-fusible Lug Wire Size AWG/ kcmil Factory Installed Copper Lug Wire Size AWG/ kcmil Factory Installed Aluminum Lug Wire Size AWG/ kcmil Field Installed Crimp Lugs Copper Lug Wire Size AWG/ kcmil Field Installed Crimp Lugs Aluminum 30A TIJ61 240Vac Fusible A TIJ61 600Vac 1 Either A TIJ62 240Vac 2 Fusible A TIJ62 600Vac 2 Fusible A TIJ62 600Vac Fusible A TIJA62 600Vac on-fusible A TIJ63 Either 14-1/0 12-1/0 6-1/0 6-2/0 240Vac or 200A TIJ64 Either / / Vac A TIJ66 Either (2) (2) (2) or (1) 750 (2) or (1) Type 4, 4X, 12 2 Mill duty type 4-24 GE Products BuyLog go.abb/industrial Rev. 1/19

25 Accessories: EMA Type 4/4X, 12 and Mill Duty Enclosures Amperes: T Crimp-type Connectors - Field Replaceable 1 Line and Load Terminals Switch Ampere Rating Equipment Ground Terminals (provision for three per switch) 1 ot furnished with switches. Lug Wire Size AWG/kcmil Thomas and Betts Product umber Burndy Product umber Copper Aluminum Copper Aluminum 30A YAV12 G2-30A YAV10-30A YAV8C-L - 60A YAV8C-L1-60A YAV6C-L - 60A YAV4CLY1-100A A A A A 1/0 - - YA25-L YA25A1 200A 1/ A 1/ A 2/ A 2/ A 3/ A 3/ A 4/ A 4/ A A A and 600A A and 600A A and 600A A and 600A A and 600A A and 600A A and 600A Switch Ampere Rating Lug Wire Size AWG/kcmil Thomas and Betts Product umber Burndy Product umber Copper Aluminum Copper Aluminum 30A A YAV8C-L - 60A YAV8C-L - 100A A A A A A A A 2/ Rev. 1/19 go.abb/industrial GE Products BuyLog 4-25

26 Accessories Type TG, T Class R Fusing Kit Field Installable, General Duty, Type TG, UL Listed When specifications permit only Class R fuses to be used, these kits may be installed in the safety switch to deter fuses other than Class R from being installed A = Clips A = Rejection Pins One kit required per two pole or three pole switch Series Prefix Ampere Rating Enclosure Type Product umber TG 30A EMA Type 1, 3R TGRK12 60A EMA Type 1, 3R TGRK22 100A EMA Type 1, 3R TGRK42 200A EMA Type 1, 3R TGRK42 TGRK22 Class R Rejection Kit Class J Field Conversion Kit, eavy Duty, Type T, UL Listed T switches, amperes, 600 volt and amperes, 240 volt, may be adapted to accept Class J fuses without a kit by moving the load-block toward the switch base and remounting. One kit required per two pole or three pole switch Series Prefix Ampere Rating System Voltage Product umber T 600A 240Vac 600Vac TJ6 T A 600Vac Move load-block T A 240Vac Move load-block Class R Fusing Kit Field Installable, eavy Duty, Type T, UL Listed When specifications permit only Class R fuses to be used, these kits may be installed in the safety switch to deter fuses other than Class R from being installed A = Clips A = Rejection Pins One kit required per two pole or three pole switch Series Prefix Ampere Rating System Voltage Enclosure Type Product umber T 30A 240Vac EMA Type 1, 3R, 4/4X, 12 TRK12B 30A 600Vac EMA Type 1, 3R TRK16B 30A 600Vac EMA Type 4/4X, 12 TRK16SA 60A 240Vac EMA Type 1, 3R, 4/4X, 12 TRK22A 60A 600Vac EMA Type 1, 3R, 4/4X, 12 TRK26A 100A 240Vac 600Vac EMA Type 1, 3R TRK46A 100A 240Vac 600Vac EMA Type 4/4X, 12 TPBRK36A 200A 240Vac 600Vac EMA Type 1, 3R, 4/4X, 12 TRK46A 400A 240Vac 600Vac EMA Type 1, 3R, 4/4X, 12 TRK56A 600A 240Vac 600Vac EMA Type 1, 3R, 4/4X, 12 TRK66A TRK46A Class R Rejection Kit 4-26 GE Products BuyLog go.abb/industrial Rev. 1/19

27 Accessories Universal Raintight Aluminum ubs For outdoor enclosures that have removable closing caps. ominal Conduit Diameter (in.) Product umber 3/4 TC75 1 TC /4 TC /2 TC150 2 TC /2 TC250 TC200 Universal Raintight ub Closing Cap for Universal Raintight Aluminum ub Product umber TCCP Replacement Red andle Grip for D Switches Product umber TGRIP Replacement andles for D Switches Amps Min. Amps Max. Max. Volts Steel Type Description Product umber 30A 30A 240V Steel andle and Pouch TRPLDL1 30A 30A 600V Steel andle and Pouch TRPLDL2 60A 200A 600V Steel andle and Pouch TRPLDL3 30A 200A 600V Stainless andle and Pouch TRPLDL4 400A 600A 600V Steel andle and Pouch TRPLDL6 400A 600A 600V Stainless andle and Pouch TRPLDL7 TRPLD6 Replacement andle Clear Line Shield Replacement Kits Series Prefix Amps Product umber T 30A TSLD1 T A TSLD3 T 200A TSLD4 TSLD1 Rev. 1/19 go.abb/industrial GE Products BuyLog 4-27

Section 4. Safety Switches.

Section 4. Safety Switches. Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG...4-5 eavy Duty, Type T...4-7 eavy Duty Stainless Steel, Type T...4-11 Mill Duty, Type T...4-13 Double Throw Switches, Type TC, TDT...4-15

More information

Section 4. Safety Switches.

Section 4. Safety Switches. Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG... 4-5 eavy Duty, Type T...4-7 eavy Duty Stainless Steel, Type T... 4-11 Mill Duty, Type T...4-13 Double Throw Switches, Type TC, TDT...4-15

More information

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures 30-600 Amperes: TG and TH 800-1200 Amperes: TC Equipment Ground Kits Ampere Rating AWG/kcmil Copper AWG/kcmil Aluminum Standard Package

More information

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install Midwest Electric Products Safety Switches Rugged, reliable and easy to install Midwest Safety Switches Features Midwest Electric Products offers a wide variety of general duty and heavy duty safety switches,

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................

More information

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753 Depth x  Width x 2.375 Height 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 7842 40A 600V 2P Switch Pass & Seymour/Legrand Catalog Number 7842 Manufacturer Pass & Seymour/Legrand Weight per unit

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1 Sect_0_Speedfax2007 /26/07 5:05 PM Page -1 SPEEDFAX TM 2007-2008 Safety Switches Contents Safety Switch Guide Form Specifications -2 Feature Comparison - Enclosure Types -4 Catalog Numbering System -5

More information

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions. Cam-Lok Single Pole Connectivity The industry standard for reliable service under the most severe operating conditions. Cam-Lok Single Pole Connectivity Cam-Lok connectors are the industry standard Cam-Lok

More information

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine eavy Industrial/ Marine Benefits builds a variety of benefits into one plug, receptacle and interlock system for your application. Safety Waterproof construction: standard neoprene O ringed interior components

More information

GE 8000-Line Motor Control Centers

GE 8000-Line Motor Control Centers GE 8000-Line -1 ENCLOSURE TYPES TYPE 1 General Purpose, Indoor Intended for use indoors, primarily to prevent accidental contact of personnel with the enclosed equipment, in areas where unusual service

More information

SECTION SECTION. EATON 2014 Arrow Hart Buyers Guide

SECTION SECTION.     EATON 2014 Arrow Hart Buyers Guide F SECTION SECTION 1 EATON 2014 Arrow Hart Buyers Guide FSECTION Cam-lok Single Pole Connectivity Table of contents Product selector guide F-3 NEMA rating system F-4 F-series F-5 E1010 F-6 E1012 F-7 F-series

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

1.1. Switching Devices

1.1. Switching Devices . Switching Devices Six-Pole Motor Circuit Contents Description Page Product Overview......................... V2-T-2 General Duty............................. V2-T-24 Heavy-Duty..............................

More information

Product Guide. NEMA pump controls.

Product Guide. NEMA pump controls. Product Guide NEMA pump controls www.usa.siemens.com/controls Class 87 full voltage pump controller with fusible disconnect switch and standard features Class 87 NEMA full starter pump control panels Product

More information

Safety Alert: Square D Safety Switches

Safety Alert: Square D Safety Switches Safety Alert: Square D Safety Switches Be Sure to Inspect Your Installed Units for Defects Schneider Electric has issued an offer safety alert on the Square D safety switch due to electrical shock hazard

More information

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle Features 30-600A, 600VAC and DC ratings UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 15852 Visible blade quick make and break switching action Panel and Flange mounted assemblies

More information

SECTION SECTION SECTION EATON 2016 Arrow Hart Buyers Guide

SECTION SECTION SECTION EATON 2016 Arrow Hart Buyers Guide F SECTION SECTION SECTION 1 EATON 2016 Arrow Hart Buyers Guide www.arrowhart.com /arrowhart FSECTION Cam-Lok Single Pole Connectivity Table of contents Product selector guide F-3 NEMA rating system F-4

More information

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry. www.usa.siemens.com/controls NEA Pump Controls Class 82 slim line NEA pump controller for the agricultural industry Answers for industry. Class 82 Slim Line NEA Pump Controller Typical applications include:

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW preliminary information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. www.usa.siemens.com/controls

More information

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection Table of Contents Introduction...2 Safety Switches...4 Symbols...6 Need for Circuit Protection...8 Fuses... 13 Fuse Ratings and Classifications... 16 Enclosures... 19 Switch Design...24 Safety Switch Ratings...29

More information

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 3150A 30A 3000A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R Safety Switches Heavy Duty 240 Volt Indoor Type Outdoor Type 3R Horsepower Ratings 240V AC Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* 2 Wire 4 Wire 3 Wire System Rating

More information

Type VBII Visible Blade Disconnect Switches

Type VBII Visible Blade Disconnect Switches Type VBII Visible Blade Disconnect es Product Guide Siemens Type VBII visible blade disconnect switches meet either UL98 or UL1741 requirements and can be used in either service entrance or branch circuit

More information

GHN424NW HHN426N HUN361AW

GHN424NW HHN426N HUN361AW GHN424NW HHN426N HUN61AW Passed The Test of Time All Murray safety switches have passed rigid testing requirements to assure reliable performance. In addition to tests designed and conducted during the

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Cam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions.

Cam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions. Plugs & receptacles Cam-Lok single pole connectivity Cam-Lok Single pole connectivity The industry standard for reliable service under the most severe operating conditions. Cam-Lok single pole connectivity

More information

IN2 Enclosed Switches and Circuit Breakers

IN2 Enclosed Switches and Circuit Breakers Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Enclosed Switches and Circuit Breakers Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. usa.siemens.com/controls

More information

Technical data OT16E3 OT160E3 UL & CSA

Technical data OT16E3 OT160E3 UL & CSA Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58

More information

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Arktite Heavy Duty Circuit Breaking Plugs and Connectors Arktite Heavy Duty Circuit Breaking Plugs and Connectors 60 A, 600 VAC/250 VDC, 50**-400 hertz Dimensions Page 968 1P Plug Connector Mating APJ Plugs Mating APR Connectors Style 1 Description Cat. # Dia.

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

Air Conditioning Disconnects

Air Conditioning Disconnects .1 Product Description............................................. 2 Application Description........................................... 2 Features, Benefits and Functions...................................

More information

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

1. Division 26 Section Elevator Shunt-Trip Fused Disconnect Switches. SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

Quik-Spec. Section Contents

Quik-Spec. Section Contents Section Contents Page Quik-Spec Coordination Panel Boards......... 238-239 Quik-Spec Power Module Switches and Panels.. 240-241 Quik-Spec DC Safety Switches.................. 242 Quik-Spec Solar Combiner

More information

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

Big performance in a small package

Big performance in a small package Series usible & Non-fusible 100 400A Suitable as a Service Entrance ing Means TIP! Manual Switching Devices: Control, oad or usible Which is Best or Your Application? Application Data Typical Control Switch

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Enclosed Rotary Switch Product Specification Sheets Table of Contents Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $

Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $ January 1 Vol. 1, ef. No. [0247] eavy uty, Fusible, - 361FK NEMA 12 Enclosure Industrial ust-tight NEMA 4 Enclosure atertight, Painted Steel Enclosure Corrosion esistant, Stainless Steel 2-Pole 40V AC

More information

Big performance in a small package

Big performance in a small package Series Fusible & Non-fusible Sprecher + Schuh s series of fused and non-fused disconnect switches comply with service entrance requirements. This family of rod operated switches is suitable for applications

More information

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com AR331 30 Amp Pin & Sleeve Recpt 3-W 3-P 250VDC/600vac Cooper Crouse-Hinds Catalog Number

More information

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

Instructions for Installation, Operation and Maintenance of: WSRD Interlocked Receptacles 30, 60 & 100 Ampere 331114-1 INSTRUCTION SHEET Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere Read instructions carefully and with full understanding for safe

More information

Selection and application guide

Selection and application guide Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure

More information

Section 7. Circuit Breaker Enclosures. BuyLog Catalog 7-1

Section 7. Circuit Breaker Enclosures.  BuyLog Catalog 7-1 NEMA Type 1 Enclosures... 7-2 NEMA Type 3R Enclosures...7-3 NEMA Type 12 Enclosures...7-4 NEMA Type 4/4X Enclosures... 7-5 Hubs and Other Accessories... 7-6 Dimensions and Outline Drawings...7-7 Dimensions

More information

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles Compatible with UL 1686 C1 Pin & Sleeve Devices Safer. Easier. Better. MENNEKES Non-Metallic MSR Switched and Interlocked

More information

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch Double-Throw, continued Ampere Rating Catalog Number Selection Safety Switch Catalog Number Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA X 30 N/A N/A N/A N/A

More information

SECTION. Watertight & Dust-Tight Plugs & Connectors

SECTION. Watertight & Dust-Tight Plugs & Connectors SECTION Watertight & ust-tight Wetguard Product Line Section Contents LIFETIME Wetguard Plugs, Connectors & Straight Blade 2-Pole 3-Wire 2-Pole 3-Wire 3-Pole 4-Wire 3-Pole 3-Wire Non- 4-Pole 4-Wire Non-

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Selection Guide Contents Descriptions Page General Information Features and Benefits 2-3 Product Illustrations General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Heavy Duty Safety

More information

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers Product Guide QR Circuit Breaker usa.siemens.com/circuitbreakers Advantages to reduce your cost and improve installation flexibility. 250A, 240V AC breakers up to 100kAIC. Updated design includes pushtotrip

More information

BUSWAY Low Voltage (Pow-R-Flex)

BUSWAY Low Voltage (Pow-R-Flex) BUSWAY LOW VOLTAGE (POW-R-FLEX) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein and

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch . Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

POWER PRODUCT Safety Switches. Contents - Safety Switches 3 SAFETY SWITCHES

POWER PRODUCT Safety Switches. Contents - Safety Switches 3 SAFETY SWITCHES POWER PRODUCT Safety es ID Heavy Duty Contents - Safety es Air Conditioning Disconnects -2 Safety Guide Form Specifications -4 Feature Comparison -6 Enclosure Types -7 Light Duty switches - -8 SE and ID

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection Table of Contents Introduction...2 Siemens Safety Switches...4 Switch Symbols...7 Need for Circuit Protection...9 Fuses... 17 Fuse Ratings and Classifications...21 Enclosures...24 Switch Design...31 Safety

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY EDSC210 -Way Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type Contact Configuration Current Rating Voltage Rating Material, Color, and

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles 1P Arktite Heavy Duty Circuit Breaking s and Receptacles Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically

More information

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles ENR Value Series Dead Front Interlocked Circuit Breaking s Cl. I, Div. & 2, roups B, C, D Cl. II, Div. & 2, roups F, Cl. III, 7BCD, 9F, 2 Dust-Ignitionproof Raintight et Locations ENP Plugs Applications:

More information

PREFACE. The term panelboard used in this booklet also applies to modular panelboards unless otherwise noted.

PREFACE. The term panelboard used in this booklet also applies to modular panelboards unless otherwise noted. PREFACE Panelboards are no longer a simple assembly of switches, fuses and circuit breakers for single ampere and voltage systems. Today, there are panelboards for a variety of electrical supply systems

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PowerSwitch Enclosed Disconnect Switch with Receptacle (EDSR) Cat. o. EDSR Rated: 30A-600VAC Max. ISTALLATIO ISTRUCTIOS DI-000-0EDSR-00A EDSR Enclosed Disconnect Switch with Receptacle (Figure 4) OTE:

More information

Hazardous Factory Sealed Control Devices

Hazardous Factory Sealed Control Devices Hazardous Factory Sealed Control Devices Description Page No. Application/Selection 428, 429 Dimensions 40 Manual Motor Starting Switches & Enclosures EDS Series 440, 44 Pilot Lights EFS Series 45 Pilot

More information

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38 Series 7 Motor (to 100A)...2 Series 7 Enclosed (to 100A)...14 Technical Information...18 Dimensions...22 Series 7 (to 315A)...29 Technical Information...36 Dimensions...38 Series 10 Fusible and Non-Fusible...45

More information

Industrial & Harsh Environment - Battery Units

Industrial & Harsh Environment - Battery Units Industrial & Harsh Environment Battery Units NEMA Enclosure Definitions...36 S12E Series...37 S24E Series...38 SL Series (Discontinued)...39 SN Series...40 S12L Series (Discontinued)...41 S12N Series...42

More information

Section 4: Circuit Breaker Enclosures

Section 4: Circuit Breaker Enclosures Section : NEMA Type 1 Enclosures...-2 NEMA Type 3R Enclosures...-3 NEMA Type 12 Enclosures...- NEMA Type /X Enclosures...-5 Hubs and Other Accessories...-6 Dimensions and Outline Drawings...-7 Dimensions

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

HCI General Purpose Disconnects

HCI General Purpose Disconnects 30 AMPERES 1oo AMPERES C General Purpose Disconnects AMPERES 0 AMPERES Quality Designed... Thoroughly Tested orsepower Rated 30-0 Amperes, 240, 480 and 0 Volts AC, 2 Volts DC with adjustable operating

More information

Small Project Product Selection Guide

Small Project Product Selection Guide Small Project Product Selection Guide At your GE Distributor today! Panelboards Transformers Safety Switches NEMA Combo Starters Lighting Contactors imagination at work Small Projects Same Day When you

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Product Guide. enclosed NEMA STARTERS

Product Guide. enclosed NEMA STARTERS Product Guide enclosed NEMA STARTERS The Right Choice for Applications that Demand the Best. Siemens NEMA Combination and Non- Combination Starters for Industrial and Construction Applications Rugged,

More information

tot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r"0? 10:5 S3» ilm; ,

tot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r0? 10:5 S3» ilm; , ' Stock ',,' ' ' ' *t *«W'-' tt M.. '. #*. ;, '. ''"' f* " ' '-', *

More information

Section 4 Square D QO Loadcentres

Section 4 Square D QO Loadcentres Section 4 Square D QO Loadcentres The Choice of Professionals Square D service entrance loadcentres feature the rugged design, high quality and proven performance that residential, multi-residential and

More information

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Product guide. Enclosed NEMA starters. usa.siemens.com/controls Product guide Enclosed NEMA starters usa.siemens.com/controls The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction

More information

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear 13 Low Voltage Switchgear Siemens Type WL low voltage metal-enclosed switchgear is designed, constructed and tested to provide superior power distribution, power monitoring and control. At the heart of

More information

Watertight Wiring Devices. A complete collection of watertight devices for demanding industrial environments wetguard

Watertight Wiring Devices. A complete collection of watertight devices for demanding industrial environments wetguard Watertight Wiring Devices A complete collection of watertight devices for demanding industrial environments wetguard 2 wetguard Leviton s Wetguard products are the most versatile and well-engineered watertight

More information

Circuit Breaker Enclosures. Section 4.

Circuit Breaker Enclosures. Section 4. Circuit Breaker Enclosures Section 4 NEMA Type 1 Enclosures...4-2 NEMA Type 3R Enclosures...4-3 NEMA Type 12 Enclosures...4-4 NEMA Type 4/4X Enclosures...4-5 Hubs and Other Accessories...4-6 Dimensions

More information

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications This table shows the optional items available on the different types of enclosures shown in this

More information