Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Size: px
Start display at page:

Download "Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle"

Transcription

1 Features A, 600VAC and DC ratings UL Recognized (file # E vol. 3) and CSA Certified under file number Visible blade quick make and break switching action Panel and Flange mounted assemblies facilite installation Panel mounted switches are variable depth Short circuit rating of 10,000 AIC with class H fuse, and of 200,000 AIC with class R or J fuses Flange mounted handles are Type 1 and 12 rated and padlockable in the off position with up to (3) padlocks with 5/16 hasps Meets UL98 requirements and suitable for both main and branch circuit applications Features and Ordering Information A complete line of aux contacts are available Load break and horsepower rated Defeatable cover interlock standard with all handles Meets NFPA79 requirements VBFS361, VBLK1 & VBH1 VBFS363F VBNFS365, VBLK & VBH2 Ordering Information 1. Determine the ratings required (amps, volts, HP, Fusible, NF), the mounting needed (Panel or Flange), and select the appropriate switch. 2. For panel mounted switches with a rigid operating shaft (30-600A), order panel mounted switch flange mounted operating handle & rigid linkage kit based on depth required. 3. For panel mounted switches with a Max-Flex operator, order panel mounted switch, Max-Flex Handle & Adapter Kit and drive cable.. Select accessories if required A handles are also rated Type 3R & X. -6

2 es Selection Horsepower Rating, es and 3-Phase Max. AC 600 Ampere Voltage 20 Volts AC 80 Volts AC 600 Volts AC Volts DC Rating Rating Number Standard Max. Standard Max. Standard Max. (max) Price $ Fusible Panel Mounted Variable Depth es - 3-Pole VBFS / VBFS / VBFS / VBFS VBFS VBFS VBFS VBFS Non-fusible Panel Mounted Variable Depth es - 3-Pole VBNFS VBNFS VBNFS VBNFS VBNFS VBNFS Fusible Flange Mounted es - 3-Pole VBFS321F 3 7 1/ VBFS322F 7 1/ VBFS361F / VBFS362F VBFS363F VBFS36F Non-fusible Flange Mounted es - 3-Pole VBNFS361F VBNFS362F VBNFS363F VBNFS36F Note: Fusible switches include fuse provisions for Class H Fuses. The load base can be moved to pre-drilled holes for Class J Fuses. If Class R Fuses are required add a Class R Fuse Clip Kit. Flange Mounted Operating Handles For use with Panel Mounted es. Included with Flange Mounted es as standard. Handle Assembly VBH A Type 1, 3R & VBH1X A Type X VBH2 00 Type 1 & VBH2R 00 & 600A Type 1, 3R & VBH2X 00 & 600A Type X Cable Kit For use with A panel mounted switches and Max-Flex handle and adapter kit. FHOEC036 36" long drive cable FHOEC08 8" long drive cable Rigid Linkage Kits For use with Panel Mounted es. Not required for Flange Mounted es. Ampere Enclosure Depth Number Rating Min Max. Price $ VBLK VBLK VBLK3 00 & VBLK 00 & Max-Flex TM Handle and Adapter Kit (Type 1, 12, 3R & X) Use with A panel mounted switches and cable kit. VBHM A Max-Flex Adapter Kit 2.00 VBNFS361, VBHM1 & FHOEC036 Rated 5 HP at 250V DC. Rated 10 HP at 250V DC. 600V DC & 600V DC horsepower rating shown requires (2) poles to be connected in series. Std. - applies when non-time delay fuses are used. Max. - applies when time delay fuses are used. Includes line base, load base, operating mechanism and line and load lugs. Order operating handle and linkage kits from tables on this page. Includes line base, load base, operating mechanism line and load lugs operating handle and required linkage. Dimensions (min. & max.) from enclosure mounting pan to outside surface of enclosure handle mounting flange for 200A switches. -7

3 Accessories HR612 HT63 HN612 Class R Fuse Clip Kits These kits prevent the installation of Class H and K fuses (one kit required per switch). Class R Fuse Clip Kits Number Price $ Description HR A, 20V Kit (HD only) HR A, 600V Kit/60A, 20V Kit HR A, 600V Kit HR A Kit HR A Kit HR A/600A Kit Class T Fuse Adapter Kits A fusible switches are field convertible to accept Class T fuses A switches are field convertible to accept Class T fuses by moving the load base to a pre-drilled T fuse position. Class T Fuse Adapter Kits Number Price $ Description HT A, 20V Kit HT A, 600V Kit HT A, 20V Kit HT A, 600V Kit 200% Neutral Kits UL listed 200% Neutrals are available on 60 & 100A switches. They are typically used with non-linear transformers or where increased neutral ampacity/lug capacity is required. 200% Neutral Kits Kit Wire Range Ampere Line & Load Rating Number Price $ Lugs (Cu/Al) 100 HN (2) #1-1/0 AWG Class J Fuse Provisions All A, 600V fusible switches are field convertible to accept Class J fuses by moving the load base to a pre-drilled J fuse position. Internal Door Latch Kits For use with enclosures with door mounted latching bar. Required when a flange mounted switch is mounted in a Hoffmann or Rittal enclosure provided with an AB cutout. DKR2 2 point (for use with enclosures less than 0" high) point (for use with DKR3 enclosures 0" or larger in height) Neutral Kits Standard Neutral Kits can be field installed in A switches. Neutral Kits Kit Ampere Rating Number Price $ 30A 600V, 60A 20V HN A, 600V & 100A HN Window Kits (Type 1, 12, 3R and x) Allows viewing of visible blades and of indicating fuses through 200A. VBWK1 30A Window Kit VBWK2 60 & 100A Window Kit VBWK A Window Kit Built to order. Allow 6 8 weeks for delivery. One kit per pole required. -8

4 HA16123 HA26123 HP61 Auxiliary Contacts Accessories The auxiliary contacts are available in 1 normally open and 1 normally closed or 2 normally open and 2 normally closed configurations. Siemens offers a PLC Auxiliary (30-200A) that has very low resistance for low voltage and current typical in PLC circuits. All auxiliary contacts make after and break before main switch contacts. Aux. Kit Ampere Rating Kit Horsepower Rating Ampere 125V AC 250V AC 28V DC 125V AC 250V AC 28V DC Rating Number Price $ Max. Max. Max. Max. Max. Max. With 1 NO & 1 NC Isolated Contacts HA /2 3/ HA /2 3/ With 2 NO & 2 NC Isolated Contacts HA /2 3/ HA /2 3/ Low Current PLC Type with 1 NO & 1 NC Gold Plated Contacts HA /2 3/ HA /2 3/ Fuse Puller Kits Fuse Puller Kits are field installable in A Type VBII Heavy Duty es (one kit required per 3-pole switch). Ampere Fuse Puller Kit Rating Number Price $ 030 HP HP HP Copper Lug Kits All switches are UL approved to accept field installed copper lug kits. Copper Lug Ampere Rating Number Price $ Description HLC (9) Lugs/Kit #1- AWG Cu 100 HLC (9) Lugs/Kit #1-1/0 AWG Cu 200 HLC (9) Lugs/Kit #6 AWG-300 Kcmil Cu A HLC (1) Lugs/Kit #1/0 AWG-600 Kcmil Cu Equipment Ground Kits Equipment Ground Lug Kits are available for all switches. HLC612 Ampere Number of Wire Range Rating Number Price $ Terminals Per Terminal (Cu/Al) HG #1- AWG 00 & 600 HG #6 AWG-250 Kcmil Built to order. Allow 6 8 weeks for delivery. -9

5 Lugs 30 & 60A switches are suitable for use with 60 or 75 C wire A switches are suitable for use with 75 C rated wire. All switches are supplied with factory installed line and load lugs. Lug Wire Ranges & Dimensions Wire Ranges (Line, Load and Standard Neutral) Ampere Rating UL Approved Wire Range Lug Wire Range 30 #1-6 AWG (Cu/AI) #1-2 AWG (Cu/Al) 60 #1-2 AWG (Cu/AI) #1-2 AWG (Cu/Al) 100 #1-1/0 AWG (Cu/Al) #1-1/0 AWG (Cu/Al) 200 #6 AWG-300 Kcmil (Cu/Al) #6 AWG-300 Kcmil (Cu/Al) 00 1/0 AWG-750 Kcmil (Cu/Al) or (1) 1/0 AWG-750 Kcmil (Cu/Al) or (2) 1/0 AWG-250 Kcmil (Cu/Al) (2) 1/0 AWG-250 Kcmil (Cu/Al) 600 (2) 1/0 AWG-750 Kcmil (Cu/Al) or (2) 1/0 AWG-750 Kcmil (Cu/Al) or () 1/0-250 Kcmil (Cu/Al) () 1/0 AWG-250 Kcmil (Cu/Al) Approximate Dimensions Mounting bracket shown with handle installed is supplied with Flange Mounted es only. All Panel Mounted es have a L shaped mounting pan with a line base, load base (if fusible) and mechanism installed. Dimensions Number A B C D (min) D (max) Fusible, Panel Mounted VBFS N/A VBFS N/A VBFS N/A VBFS N/A VBFS N/A VBFS36 17 N/A VBFS N/A VBFS N/A Non-fusible, Panel Mounted VBNFS N/A VBNFS N/A VBNFS N/A VBNFS N/A VBNFS N/A VBNFS N/A Fusible, Flange Mounted VBFS321F N/A VBFS322F N/A VBFS361F N/A VBFS362F N/A VBFS363F N/A VBFS36F N/A Non-fusible, Flange Mounted VBNFS361F N/A VBNFS362F N/A VBNFS363F N/A VBNFS36F N/A B A D C Dimension C for panel mounted switches indicates the minimum width from the left hand edge of the switch mounting pan to the right hand inside surface of the enclosure. -10

Type VBII Visible Blade Disconnect Switches

Type VBII Visible Blade Disconnect Switches Type VBII Visible Blade Disconnect es Product Guide Siemens Type VBII visible blade disconnect switches meet either UL98 or UL1741 requirements and can be used in either service entrance or branch circuit

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

POWER PRODUCT Disconnect Switches Contents

POWER PRODUCT Disconnect Switches Contents 4 POWER PRODUCT Disconnect es Contents Compact Non-Fusible es 4-2 Rotary and Toggle Selection 4-4 Dimensions and Wire Ranges 4-5 Type VBII (0-A) Features and Ordering Information 4-6 and Handle Selection

More information

General and Heavy Duty Safety Switches

General and Heavy Duty Safety Switches General and Heavy Duty Safety es Accessories 10/01/13 Selection 4 Class R Fuse Clip Kits All General Duty and Heavy Duty es are field convertible to accept Class R Fuse Clip Kits. The kits prevent the

More information

File E Vol. 3 Sec. Gen. Page 1 Issued: Revised: Type VBII enclosed switch components for OEM assembly.

File E Vol. 3 Sec. Gen. Page 1 Issued: Revised: Type VBII enclosed switch components for OEM assembly. File E252 Vol. Sec. Gen. Page Issued: 2007-0-02 Revised: 20-0-8 GENERAL PRODUCT COVERED: Type VBII enclosed switch components for OEM assembly. * GENERAL CONSTRUCTION: This product shall comply with the

More information

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1 Sect_0_Speedfax2007 /26/07 5:05 PM Page -1 SPEEDFAX TM 2007-2008 Safety Switches Contents Safety Switch Guide Form Specifications -2 Feature Comparison - Enclosure Types -4 Catalog Numbering System -5

More information

Flange Mounted Disconnect Switch. Installation Instructions. Item: I.L. No A00 1 / 12 VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F

Flange Mounted Disconnect Switch. Installation Instructions. Item: I.L. No A00 1 / 12 VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F Flange Mounted Disconnect Switch Item: VBFS321F VBFS361F VBFS322F VBFS362F VBFS363F VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F Installation Instructions Hazardous Voltage. 1 / 12 I.L. No. 500524A00

More information

Switches. Safety and Disconnect Switches. Heavy Duty Safety Switch Standards and Ratings

Switches. Safety and Disconnect Switches. Heavy Duty Safety Switch Standards and Ratings Safety and Disconnect es Contents Pages Heavy Duty Safety es Safety Features........................18/2 Selection, 240V Fusible........................18/3 Selection, 600V Fusible........................18/4

More information

POWER PRODUCT Safety Switches. Contents - Safety Switches 3 SAFETY SWITCHES

POWER PRODUCT Safety Switches. Contents - Safety Switches 3 SAFETY SWITCHES POWER PRODUCT Safety es ID Heavy Duty Contents - Safety es Air Conditioning Disconnects -2 Safety Guide Form Specifications -4 Feature Comparison -6 Enclosure Types -7 Light Duty switches - -8 SE and ID

More information

General and Heavy Duty Safety Switches Accessories

General and Heavy Duty Safety Switches Accessories eneral and Heavy uty Safety es Accessies Selection HR612 HT63 HN612 lass R use lip Kits All eneral uty and Heavy uty es are field convertible to accept lass R use lip Kits. The kits prevent the installation

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R Safety Switches Heavy Duty 240 Volt Indoor Type Outdoor Type 3R Horsepower Ratings 240V AC Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* 2 Wire 4 Wire 3 Wire System Rating

More information

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Enclosed Rotary Switch Product Specification Sheets Table of Contents Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

FUSIBLE DISCONNECT SWITCHES

FUSIBLE DISCONNECT SWITCHES FUSIBLE DISCONNECT SWITCHES HIGHLIGHTS: Double break contacts per pole up to 400 A Touch safe fuse covers/line shrouding standard Service Entrance Rated Compact Footprints Front operated switches Side

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

Load Break Disconnect Switches FSLBS

Load Break Disconnect Switches FSLBS Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable

More information

footprint of traditional fusible switches

footprint of traditional fusible switches Disconnect switches Contents Section page Description Compact Circuit Protector (CCP) disconnect switches Class CC, UL supplemental and IEC 0x38mm (CCP) -3 Class CF CUBEFuse (CCP-CF) 4-5 Compact Circuit

More information

Low Voltage Products. Catalog. Flange Handle Operated Disconnect Switches. Non Fusible 30A A Fusible 30A - 800A

Low Voltage Products. Catalog. Flange Handle Operated Disconnect Switches. Non Fusible 30A A Fusible 30A - 800A Low Voltage Products Flange Handle Operated Switches Non Fusible 0A - 0A Fusible 0A - 800A Flange Handle Operated Switches Non Fusible 0A - 0A Fusible 0A - 800A 7 Page Shaft operated Cable operated Amp.

More information

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A) Bulletin 494C Cable Operated Disconnect Switch Kit () Installation Instructions (Cat 494C- _ Series : ) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.

More information

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application Bussmann Open and Enclosed Rotary Disconnect Switches Exceptional Breadth and Availability f Your Application 2 Visit us on the web at www.cooperbussmann.com/disconnects Table of Contents Compact Circuit

More information

Fusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web: -

Fusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web:  - disconnect A 1200A, 600VAC Disconnect Disconnect ABB PowerLine includes seven different amperage sizes from A to 1200A. All ABB fusible are designed to meet customer requirements in terms of high interrupting

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

for Non-Fusible Disconnect Switches

for Non-Fusible Disconnect Switches Overview for Non- Disconnect Switches CDNF16 CDNF100A3 CDNF16A3, CDNF25A3, CDNF32A3 CDNF30A3, CDNF60A3, CDNF100A3 CDNF160 number 3 pole CDNF16A3 CDNF25A3 CDNF32A3 CDNF45A3 CDNF63A3 CDNF30A3 CDNF60A3 CDNF100A3

More information

GHN424NW HHN426N HUN361AW

GHN424NW HHN426N HUN361AW GHN424NW HHN426N HUN61AW Passed The Test of Time All Murray safety switches have passed rigid testing requirements to assure reliable performance. In addition to tests designed and conducted during the

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch . Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most up-todate disconnect

More information

T CLASS T FUSE BLOCKS

T CLASS T FUSE BLOCKS Ferraz Shawmut Fuse Blocks accommodate fuses up to 600A. Insulators are either of durable, glassfilled polycarbonate (GFPC) or phenolic with verified dielectric strength in excess of 2500V. Ferraz Shawmut

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D) Bulletin 494V Variable Depth Disconnect Switch Installation Instructions (Cat 494V-DS400; -DSX400 - Series D) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.

More information

Compact Circuit Protector

Compact Circuit Protector Supersedes February 2019 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP2) 2011/65/EU CCP2 switch up to 100 A 200 A CCP2 switch 400 A CCP2 switch Contents Page 30, 60 and 100 amp switches s and

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch Double-Throw, continued Ampere Rating Catalog Number Selection Safety Switch Catalog Number Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA X 30 N/A N/A N/A N/A

More information

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A) Bulletin 494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 494C- _ Series : 600A) ATTENTION: To prevent electrical shock, disconnect from power source before installing or

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Product Guide. NEMA pump controls.

Product Guide. NEMA pump controls. Product Guide NEMA pump controls www.usa.siemens.com/controls Class 87 full voltage pump controller with fusible disconnect switch and standard features Class 87 NEMA full starter pump control panels Product

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Safety and Disconnect Switches

Safety and Disconnect Switches Safety and Disconnect es Industrial Controls Product 2017 Section c o n t e n t s Heavy Duty Enclosed Safety es Features and Benefits /2 240V Selection /3 600V Selection /4 - /5 es with Viewing Window

More information

Disconnect switches Non-fusible Fusible Enclosed

Disconnect switches Non-fusible Fusible Enclosed Disconnect switches Non-fusible Fusible Enclosed Low voltage disconnect switches from ABB ABB is committed to offering high quality and innovative low voltage products. ABB s disconnect switch lines are

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................

More information

Safety Switches. c o n t e n t s SPEEDFAX TM 2017

Safety Switches. c o n t e n t s SPEEDFAX TM 2017 Safety Switches SPEEDFAX TM 2017 Section General Duty Switch Heavy Duty Switch Window Switch c o n t e n t s Safety Switch Guide Form Specifications -2 Feature Comparison -3 Enclosure Types - ing System

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable

More information

Switches Safety and Disconnect Switches

Switches Safety and Disconnect Switches es Safety and Disconnect es Contents Pages Contents Pages Heavy Duty Enclosed Safety es Features and Benefits.......................... 18/2 240V Selection............................... 18/3 600V Selection..........................

More information

Class T 300 & 600 Volt Fuse Blocks F B 300 & 600V CLASS T FUSE BLOCKS RATINGS: FEATURES/BENEFITS: RECOMMENDED FUSE USAGE: CLIP & CONNECTOR TYPES

Class T 300 & 600 Volt Fuse Blocks F B 300 & 600V CLASS T FUSE BLOCKS RATINGS: FEATURES/BENEFITS: RECOMMENDED FUSE USAGE: CLIP & CONNECTOR TYPES Class T 300 & 600 Volt use locks USE LOCKS 300 & 600V CLASS T USE LOCKS RATINGS: Volts: 300VAC/DC, 600VAC/DC Amps: 30A, 60A, 00A, 200A, 400A, 600A SCCR: 200kA Mersen Class T fuse blocks accommodate Class

More information

Overview for Fusible Disconnect Switches

Overview for Fusible Disconnect Switches Overview for Fusible Disconnect Switches CFD30CC3 FD800L3 CFD30AJ3 CFD60J3 CFD100J3 FD400J3 FD600J3 FD800L3 number 3 pole CFD30ACC3 CFD30AJ3 CFD60J3 CFD100J3 CFD200J03 FD400J3 FD600J3 FD800L3 General purpose

More information

1.1. Switching Devices

1.1. Switching Devices . Switching Devices Six-Pole Motor Circuit Contents Description Page Product Overview......................... V2-T-2 General Duty............................. V2-T-24 Heavy-Duty..............................

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes April 2014 UL Class CC, CF (CUBEFuse ), Midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-Pole Class CC, Midget, 10x38mm Description & Specifications....

More information

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures 30-600 Amperes: TG and TH 800-1200 Amperes: TC Equipment Ground Kits Ampere Rating AWG/kcmil Copper AWG/kcmil Aluminum Standard Package

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes March 2016 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail 2011/65/EU Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description

More information

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm Supersedes October 2015 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description and

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 00A 30A 00A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

Compact Circuit Protector

Compact Circuit Protector Technical Data 10801 Supersedes August 018 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP) Contents Page 011/65/EU and specifications.... -3 Catalog numbers.... 4 Conductor information and available

More information

UL 508 Non-Fusible Disconnect Switches

UL 508 Non-Fusible Disconnect Switches UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection Table of Contents Introduction...2 Safety Switches...4 Symbols...6 Need for Circuit Protection...8 Fuses... 13 Fuse Ratings and Classifications... 16 Enclosures... 19 Switch Design...24 Safety Switch Ratings...29

More information

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview

More information

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth

More information

+ + + OS400J03 + OXP12X280 + OHB145J12 + OZXA-24. UL general purpose amp rating. UL Fuse Type 600V Catalog number Catalog number Catalog number

+ + + OS400J03 + OXP12X280 + OHB145J12 + OZXA-24. UL general purpose amp rating. UL Fuse Type 600V Catalog number Catalog number Catalog number Disconnect Base & DIN rail mounted 1200A For a complete assembly, please select one of each: 1 switch (page.22) 1 handle (page.) 1 shaft (page.32) 1 terminal lug kit (page.34) NOTE: For additional accessories,

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled

More information

UL 508 Non-Fusible Disconnect Switches

UL 508 Non-Fusible Disconnect Switches UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.

More information

Section Contents. Disconnect Switches

Section Contents. Disconnect Switches Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, w Neutral, Visible-Blade, Heavy Duty Safety Switches

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, w Neutral, Visible-Blade, Heavy Duty Safety Switches Step Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, w Neutral, Visible-Blade, Heavy Duty Safety Switches Work Description All work should be performed in accordance with NFPA 70E. Tools

More information

UL 98 Fusible Disconnect Switches

UL 98 Fusible Disconnect Switches UL 98 Fusible isconnect witches ICONNECT WITCHE Mersen s fusible disconnect switches are listed to UL 98 and bear the CE mark conforming to IEC 60947-3. They are service entrance devices capable of fully

More information

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

1. Division 26 Section Elevator Shunt-Trip Fused Disconnect Switches. SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

Cable-Operated Disconnect Switches. Accessories

Cable-Operated Disconnect Switches. Accessories Cable-Operated Disconnect Switches Accessories Description For Use With Auxiliary Contacts 1 N.O. Contact 1494C, 1494F, 1494V, and 1494G ( 1495-N8 1 N.O. Contact (low-level switching) A) Disconnect Switches

More information

600V, Non-Fusible, (3-Pole, 3 Phase)

600V, Non-Fusible, (3-Pole, 3 Phase) 0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600V. International acceptance. Disconnect switches. Non-fusible

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600V. International acceptance. Disconnect switches. Non-fusible Disconnect disconnect 1A 1A, 0V Disconnect ABB SwitchLine includes 1 different amperage sizes from 1A to 1A. The basic construction provides flexibility, safety, and high performance in an extremely compact

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600V. International acceptance. Disconnect switches. Non-fusible

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600V. International acceptance. Disconnect switches. Non-fusible Disconnect disconnect 1A 1A, 0V Disconnect ABB SwitchLine includes 1 different amperage sizes from 1A to 1A. The basic construction provides flexibility, safety, and high performance in an extremely compact

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection Table of Contents Introduction...2 Siemens Safety Switches...4 Switch Symbols...7 Need for Circuit Protection...9 Fuses... 17 Fuse Ratings and Classifications...21 Enclosures...24 Switch Design...31 Safety

More information

IN2 Enclosed Switches and Circuit Breakers

IN2 Enclosed Switches and Circuit Breakers Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Enclosed Switches and Circuit Breakers Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals

More information

Selection and application guide

Selection and application guide Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure

More information

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings.

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings. Ratings Ferraz Shawmut Class H, K and R Fuse Blocks accommodate all Class H, K and R 250 and 600V power fuses. A choice of screw, pressure plate, box and special order stud connectors fit a wide range

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

Disconnect Switches and Operating Mechanisms. Section 7.

Disconnect Switches and Operating Mechanisms. Section 7. Disconnect Switches and Operating Mechanisms Section 7 Premium Duty QMW, Heavy Duty QMR Individual Components...7-2 Factory Assembled Fuse Clips...7-4 Handle Operators Product Ordering Tables...7-7 Accessories

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised: File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,

More information

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS Prepared by: SXZO DISCONNECT SWITCH REQUIREENTS FOR DISTRIBUTED GENERATION CUSTOERS 060559 Department: Electric Distribution Section: Design and Construction Approved by: D.Jantz (DWJ7) Date: 8/15/17 Rev.

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW preliminary information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. www.usa.siemens.com/controls

More information

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry. www.usa.siemens.com/controls NEA Pump Controls Class 82 slim line NEA pump controller for the agricultural industry Answers for industry. Class 82 Slim Line NEA Pump Controller Typical applications include:

More information

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, Heavy Duty Safety Switches

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, Heavy Duty Safety Switches Step Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, Heavy Duty Safety Switches Work Description All work should be performed in accordance with NFPA 70E. Tools Required: Personal Protective

More information

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein. 16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional

More information

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A Conformity to standards (1) Changeover switches svr-ul_14_b_1_cat > EC 6947-3 > UL98, Guide WHTY, file 1138 > UL18, Guide WPYV, file 31792 > CSA 22.2#4, Class 4651-2 (1) Product reference on request. svr_136_a_2_cat

More information

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches Bulletin 494V Variable Depth, Flange Operated Disconnect Switch Kits for and Amperes (Series A) Switches ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.

More information