Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1

Size: px
Start display at page:

Download "Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1"

Transcription

1 Sect_0_Speedfax2007 /26/07 5:05 PM Page -1 SPEEDFAX TM Safety Switches Contents Safety Switch Guide Form Specifications -2 Feature Comparison - Enclosure Types -4 Catalog Numbering System -5 General Duty Safety Switches General Duty Plug Fuse Type, /240V Fusible and Non-Fusible General Duty Switches Features -7 General Duty Switches -8 Heavy Duty Safety Switches Features -9, 240V Fusible -10, 600V Fusible -11, 600V Non-Fusible -12 Window Switches -1 Special Application Switches 4-Pole and 6-Pole, -14 Interlocked Receptacle- -15 Non-Metallic, -16 Accessories-General and Heavy Duty Switches Class R Fuse Clips -17 Class J Fusing -17 Class T Fuse Adapter Kits -17 Neutral Kits % Neutral Kits -17 Auxiliary Contacts -18 Fuse Puller Kits -18 Copper Lug Kits -19 Equipment Ground Kits -19 Isolated Ground Kits -19 Interchangeable Hubs -20 Compression Lug, Neutral Barrier Kit -20 Lugs and Wire Ranges -20 Multiple Padlocks -20 Kirk-Key Interlocks -20 Dimensions and Weights General and Heavy Duty Switches Type 1 and R Knockout Diagrams Non-Metallic and Receptacle Switch Dimensions Pole and 6-Pole Switch Dimensions -28 Double-Throw Switches Dimensions -1 Enclosed Rotary Disconnect Switches -2 - VBII Safety Switch Replacement Parts -4 SAFETY Residential Commercial Industrial Siemens / Speedfax Previous folio: -1

2 Sect_0_Speedfax2007 /26/07 5:05 PM Page -2 Type VBII Safety Switches Guide Form Specifications Product Overview SAFETY Application Short Circuit Withstand Ratings Fuses Cover Interlocks General Duty Heavy Duty Double Throw General Duty Switches are intended for applications where reliable performance and continuity of service are needed, but where duty requirements are not severe and usual service conditions prevail. (These switches are intended for use primarily with supply circuits rated 240V AC or less where the available fault current is less than 100,000A when used with Class R or T fuses or 10,000A max. when used with Class H fuses.) Suitable for use on systems capable of delivering not more than 100,000 RMS symmetrical amperes of fault current as follows: Sw. Rating AIC Rating Protective Device 0-600A 10,000 Circuit Breaker 0-600A 10,000 Class H Fuse 0-600A 100,000 Class R Fuse A 100,000 Class J or T Fuse Fusible switches will accept the following UL class fuses: 0 LF - 0A max plug Fuses 0-600A GF Class H & K, Class R with kit A GF Class J-move base GF Class T with kit A GF Class T-move bases Voidable cover interlocks on switches prevent the switch door from being opened when in the ON position. No cover interlock on 0A Type R or on plug fuse type switches. Heavy Duty Switches are intended for use in applications where: 1. Rugged construction, reliable performance, continuity of service and ease of maintenance are emphasized, or 2. Available fault currents higher than 10,000A are likely to be encountered, such as in manufacturing plants, mass production industries, and commercial, institutional and other large buildings served by network systems or transformers of higher capacities.. System voltage is 600V AC or DC Max. 4. A Type 12 or 4 / 4X enclosure is required. Suitable for use on systems capable of delivering not more than 200,000 RMS symmetrical amperes of fault current as follows: Sw. Rating & Tpye AIC Rating Protective Device All Heavy Duty & DT 10,000 Circuit Breaker 0-600A HD & DT 10,000 Class H Fuse 60A Compact HD 100,000 Class R, J or T Fuse GD & 4P DT 100,000 Class R, J or T Fuse 0-600A HD 200,000 Class R, J or T Fuse 0-600A DTF & DTNF DT 200,000 Class R, J or T Fuse 800 & 1200A HD & DT 200,000 Class L or T Fuse Fusible switches will accept the following UL class fuses: 0-600A HF Class H & K, Class R with kit 0-600A, 600V HF Class J-move base A, 240V HF Class J-move base A HF Class T with kit A HF Class T-move bases A HF Class L, Class T with kit Voidable dual cover interlocks standard on all heavy duty switches. Prevents cover from being opened when switch is in the ON position and prevents switch from being turned ON when door is opened. Double throw switches are intended to transfer loads from one power source to another. All 2 & pole double throw switches are suitable for use as service equipment. All are UL Listed. Switches are rated for use on systems with an available fault current of up to 10,000 AIC when protected with Class H fuses or either 100,000 or 200,000 AIC when protected with Class R, J or Class T fuses. They can also be used to connect a single source of power to either of two loads, In this application it is necessary to field modify fusible switches so that the fuses are on the load side of the switching mechanism. Fusible switches will accept the following UL class fuses: 0-200A DT & F Class H & K, Class R with kit 0 & 60A 600V DT Class J-move base A DT Class J-move base, Class T with kit A DT Class J-standard, Class T-move bases 400A F Class T-standard Dual cover interlocks standard on all double throw switches. Prevents cover from being opened when switch is in the ON position and prevents switch from being turned ON when door is opened. Underwriters Laboratories, Inc. NEMA Specifications Groundable Neutral Padlocks HP & Load Break Ratings Listed by UL under file #E4776 as enclosed switches and also suitable for use as service equipment (where applicable). UL98 Enclosed and Deadfront Switches. Meet NEMA standard KS for type GD switches. Fusible switches have groundable neutral blocks factory installed. Non-fusible switches accept field addable neutrals. All neutrals are bondable for service entrance use. Padlockable cover latch. OFF padlock provisions on handle. Meet NEMA standard KS for type HD switches. All switches (both Fusible and Non-Fusible) are either supplied with factory installed neutrals or accept field addable neutrals. All neutrals are bondable for service entrance use. Padlockable cover latch and multiple OFF padlock provisions on handle. All General Duty, Heavy Duty and Double Throw Switches are both load break and horsepower rated. Meet NEMA standard KS type GD for DTG & type HD for DT, F & NF switches. All except 4 pole switches will accept field addable neutrals except that DTG 100 & 200A switches are also available with factory installed neutrals. All neutrals are bondable for service entrance use. Padlockable cover latch and multiple OFF padlock provisions on handle. The protective device can either be a fuse installed in a fusible switch or an upstream fuse or circuit breaker protecting a non-fusible switch. The ampere rating of the upstream protective device must not exceed the switch ampere rating. All 4 pole and fusible double switches with catalog numbers starting with F are rated 100,000 AIC max. Class T kit available for 240V max. applications on 1200A switches. -2 Siemens / Speedfax Previous folio: -2

3 Sect_0_Speedfax2007 /26/07 5:05 PM Page - Feature Comparison Product Overview General Heavy Double Features / Duty Duty Throw Ratings 0 thru 600 Amps 800 and 1200 Amps 240 Volt AC 600 Volt AC 250 Volt DC 600 Volt DC Double-break visible blade design (0-200A) Quick-make, quick-break switching action Highly visible ON/OFF handle indication Handle design for hook stick operation Padlockable cover latch Padlockable handle Single voidable cover interlock Dual voidable cover interlock Type 1 enclosure Type R enclosure Type 12 enclosure Type 4 / 4X enclosures Generous wiring gutters that meet UL and NEC wire-bending space requirements Lugs suitable for copper or aluminum at 60 or 75 C CU/AL wire lugs that meet UL 486B requirements Suitable for field-convertible compression connectors All plated copper current carrying parts (except lugs) Spring reinforced Fuse Clips (except 0A general duty) Clear pivoting line terminal shield Replacement parts Field addable 200% neutral Provisions for UL Class T, R and H Fuses Provisions for UL Class J and L Fuses Metal nameplate Aux. switch kits Type 4X with stainless steel interior parts Rolled flange enclosure design (0-200A) UL approved HP ratings for high efficiency motors Isolated ground kits on in operation off Double Break Switching Action Like the time-proven Vacu-Break Design, the Siemens VBII double break switching action breaks the arc in two places in 0-200A ratings. This reduces heat generation and increases switching speed by doubling the breaking distance. The result is enhanced performance and increased longevity. We also provide the most visible blade design available today. Unlike conventional knife blade switches, the blades are self-aligning to ensure positive contact. In addition, they have no wear and friction point since the electrical hinge has been eliminated. The result is a very fast, positive and reliable switching action for even the most severe applications. SAFETY 400 & 600A fusible, double-throw switches accept only Class J or T fuses. 0A general duty switches have fuse clips constructed of spring type copper. Not supplied on 0A outdoor & plug fuse switches A Type VBII in stainless steel enclosures A. 200A general duty switches have aluminum neutral assemblies A GD & DT and A HD switches will accept Class T fuses. - Siemens / Speedfax Previous folio: -

4 Sect_0_Speedfax2007 /26/07 5:05 PM Page -4 Safety Switches General Duty and Heavy Duty Product Overview SAFETY Enclosure Types A Type 1 enclosures are intended for indoor use primarily to provide protection against contact with the enclosed equipment in locations where unusual service conditions do not exist. B Type R enclosures are intended for outdoor use primarily to provide a degree of protection against falling rain and sleet and must remain undamaged by the formation of ice on the enclosure. They are not intended to provide protection against conditions such as dust, internal condensation, or internal icing. C Type 4, 4X enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust, rain, splashing water and hose-directed water. They are not intended to provide protection against conditions such as internal condensation or internal icing. Also meets 4X definition by providing a high degree of protection against corrosion. Siemens 0-200A stainless steel 4X switches are supplied stainless interior parts and hardware as standard. D Type 4 enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust, rain, splashing water and hose-directed water. They are not intended to provide protection against conditions such as internal condensation or internal icing. E Type 12 enclosures are intended for indoor use primarily to provide a degree of protection against dust, falling dirt and dripping water. They are not intended to provide protection against conditions such as internal condensation. Type 7/9 enclosures for use in hazardous locations. Use with molded case switches listed on page For enclosure catalog numbers and dimensions see page 5-2 & Note: Type 1 60A General Duty and Type 1 0 & 60A Heavy Duty Switches have tangential knockouts which are UL approved for bonding conduits for non-service entrance conductors. A C D B E Load Break Ratings All Siemens safety switches are load break rated. The load break rating is assigned by UL after the switching unit has successfully performed the following tests for general use enclosed switches: Load Break Ratings Number of Switch ON/OFF Number of Operations Ampere Operations With Without Rating per Minute Current Current Total Horsepower Ratings All Siemens safety switches, where appropriate, are horsepower rated. The assignment of such ratings is made by UL only after the switching unit has undergone tests to determine its acceptability. In addition, the unit must successfully perform on an overload test series which includes repeated interruption of the locked rotor current of the motor for which it is to be rated as follows: Horsepower Ratings Max HP Number of ON/OFF Number of Cycles Rating Operations per minute of Operation VBII Type 12 switches are also rated R & S for outdoor use. Type R is defined in B above. S rated enclosures provide a degree of protection against windblown dust and allow operation when the enclosure is ice laden. -4 Siemens / Speedfax Previous folio: -4

5 Sect_0_Speedfax2007 /26/07 5:05 PM Page -5 Catalog Numbering System Type VBII Safety Switch Catalog Numbering System H F 6 4 N R CU Product Overview Switch Type L = General Duty 10k AIC Max. (Plug Fused & 60A Max Non-Fused) G = Gen. Duty H = Heavy Duty DT = Double Throw DTG = General Duty DT Special Applications With: CH = Crouse-Hinds Receptacle CJ = Factory J Fuse Spacings CR = Class R Clips Installed CU = Factory-Installed Copper Lugs G = Factory-Installed Ground Bar H = Height or Size Reduced L = Oversized Enclosure PN = Pyle-National Receptacle W = Viewing Window Fused or Non-Fused F = Fused NF = Non-Fused Number of Poles 1 = 1 2 = 2 = 4 = 4 6 = 6 Enclosure Type Omit = Type 1, Indoor R = Type R, Outdoor S = Type 4 / 4X, Stainless Steel X = Type 4 / 4X, Non-Metallic J = Type 12, Industrial XL = Type 4/4X Non-Metallic Less Line & Load Lugs With or Without Neutral Omit = Less Neutral N = With Neutral SAFETY Voltage 1 = 120V or 120/240V 2 = 240V 6 = 600V Amperes 1 = 0A 2 = 60A = 100A 4 = 200A 5 = 400A 6 = 600A 7 = 800A 8 = 1200A Type VBII Accessories Catalog Numbering System H R 6 4 Switch Type H = Heavy Duty G = General Duty Accessory Type A1 = Auxiliary Switch 1/NO and 1/NC A2 = Auxiliary Switch 2/NO and 2/NC A = Auxiliary Switch Low Current CL = Compression Lug Barrier / Mounting Kit G = Ground Lug Kit G2 = Insulated Ground Lug Kit LC = Copper Lug Kit N = Neutral N2 = 200% Neutral P = Fuse Puller Kit R = Class R - Fuse Clip Kit T = Class T - Fuse Kit Amperes 1 = 0A 2 = 60A 12 = 0/60A = 100A 2 = 60/100A 12 = 0/60/100A 124 = 0/60/100/200A 4 = 200A 56 = 400/600A 5678 = 400/600/800/1200A 78 = 800/1200A Maximum Voltage 2 = 240V Max 6 = 600V Max Note: Catalog numbering systems above do not apply to 4-pole double throw switches & accessories. -5 Siemens / Speedfax Previous folio: -5

6 Sect_0_Speedfax2007 /26/07 5:05 PM Page -6 SAFETY General Duty Enclosed Switches Plug Fuse and 60A Special Application Type Features Compact size Horsepower rated Indoor and outdoor enclosures Quick make-quick break mechanism Visible ON - OFF indications Padlock-off handle feature Door padlock provision Bondable neutral (where indicated) Lugs suitable for copper or aluminum wire UL Listed Fuses not included Switches accept only plug fuses Hubs see page -20 Lugs see page -20 Dimensions (inches) Type Height Width Depth R Wire Range Table Switch Type Wire Range 120/240 Volt Fusible Cu/Al 0 Amp #14 to #8 AWG 120/240 Volt Non-Fusible Cu/Al 60 Amp #14 to # AWG Indoor Type 1 Outdoor Type R Horsepower Ratings Ampere Catalog List Ship. Wt. Catalog List Ship Wt. 1-Phase, 2-Wire Rating Number Price $ Pkg. of 10 Number Price $ Pkg. of 10 Standard Maximum 120/240 Volt Fusible 1-Pole and Solid Neutral 120 Volt 1-Phase, 2-Wire 0 LF111N LF111NR Pole and No Neutral 0 Use 2-Pole and Solid Neutral 2-Pole and Solid Neutral 120/240 Volt 1-Phase, 2-Wire 120/240 Volt 1-Phase, -Wire 0 LF211N LF211NR Volt Non-Fusible 2-Pole Special Application Switch 1 or 2-Pole No Fuse 240 Volt 1-Phase, 2-Wire 60 LNF222R For inches / millimeters conversion, multiply inches by Dual horsepower ratings: Std. applies when non-time delay plug fuses are installed. Max applies when time-delay plug fuses are installed. Has service entrance label. UL Listed as Enclosed Switches (suitable for use as service equipment where indicated) under File #E4776. (NEMA) Type G.D. Federal Spec. W-S-865C type LD or type NDS Bottom cable entry and exit only. No hub provision supplied. GSGK60 is included and factory installed. Line lugs will accept and are UL approved for #14 to #6 Cu/Al cable. Features also apply to 2- and -pole, 0A general duty switches on page Discount Schedule GDSS Siemens / Speedfax Previous folio: -6

7 Sect_0_Speedfax2007 /26/07 5:05 PM Page -7 General Duty Safety Switches Features (60-600A) Product Overview SAFETY Cover interlock 2. Tangential knockouts through 600A for easy conduit lineup. Quick-make, quick-break operating mechanism that ensures positive operation 4. Provisions for T, R, J, H, and K class fuses (T & J A) 5. Generous wiring gutters that meet or exceed NEC wire-bending space requirements 6. Visible blade, double-break switch action 7. Positive 2 or point mounting 8. Highly visible red handle grip 9. Informative door labeling which includes replacement parts list 10. Handle and cover padlocking provisions 11. Side-hinged door that opens 180 degrees for easier wiring 12. A unique enclosure design that adds rigidity and strength. Its rolled edge prevents cuts and scrapes to conductors and to installer s hands -7 Siemens / Speedfax Previous folio: -7

8 Sect_0_Speedfax2007 /26/07 5:05 PM Page -8 General Duty Safety Switches SAFETY Indoor Type 1 Outdoor Type R Horsepower Ratings 240V AC Phase, 2-Phase, -Phase, Volt Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* 2-Wire 4-Wire -Wire DC System Rating Number Price $ Std. Pkg. Number Price $ Std. Pkg. Std. Max. Std. Max. Std. Max. Std. 240 Volt Fusible 2-Pole, 2-Fuse, and Solid Neutral 00 GF221N GF221NR GF222N GF222NR GF22N GF22NR GF224N GF224NR GF225NH GF225NRH GF225N GF225NR GF226NH GF226NRH GF226N GF226NR Pole, -Fuse, and Solid Neutral 240 Volt AC/250 Volt DC 240 Volt AC/250 Volt DC 00 GF21N GF21NR GF22N GF22NR GF2N GF2NR GF24N GF24NR GF25NH GF25NRH GF25N GF25NR GF26NH GF26NRH GF26N GF26NR Volt Non-Fusible 2-Pole or -Pole 240 Volt AC/250 Volt DC 00 GNF GNF21R GNF GNF22R GNF GNF2R GNF GNF24R GNF Use 600V Switch HNF65R GNF Use 600V Switch HNF66R * In pounds (lbs). Dual horsepower ratings: Std.- applies when non-time delay fuses are installed. Max.- applies when timedelay fuses are installed. These switches are UL-listed for application on grounded B-phase systems. Suitable for use on -phase motor loads. Service entrance labeled. Has provision for ECHA type hub. 5 switches per standard package. 10 switches per standard package. Height reduced switch (45.25 rather than 56 inches in height) for use with 500MCM or smaller conductors. -8 Discount Schedule GDSS Siemens / Speedfax Previous folio: -8

9 Sect_0_Speedfax2007 /26/07 5:06 PM Page -9 Heavy Duty Safety Switches Features SAFETY Quick-make, quick-break operating mechanism that ensures positive operation. 2. Visible blade, double-break switching action.. Arc chutes dissipate heat and prolong switch life. 4. Highly visible red handle grip. Designed for hook stick operation. 12. Unique enclosure design increases rigidity and prevents cuts and scrapes to conductors and installer s hands. 1. Spring reinforced fuse clips that assure reliable contact for cool operation. 14. Door latch securely holds door closed and allows cover padlocking Defeatable dual cover interlock. 6. Center punch provided for field drilling to allow ON padlocking. 7. Handle can be padlocked in the OFF position with up to () padlocks with 5/16" hasps. 8. Generous top, bottom and side gutters that meet or exceed NEC wire-bending space requirements. 9. Informative door labeling which includes replacement parts list. 10. Tangential knockouts through 600A for easy conduit lineup. 11. Side-hinged door that opens past 180 degrees for easier wiring. 15. Front removable mechanical lugs that are suitable for CU/AI 60 or 75 C conductors. 16. Lugs are field convertible to copper body and to a wide variety of compression connectors. 17. Hinged clear line terminal shield with probe holes for inspecting or testing line side terminals. 18. Embossed aluminum nameplate on Heavy Duty Switches provides highly visible ON/OFF indication. 19. Drawn cover for increased rigidity and resistance to abuse. 20. Top key hole and bottom mounting holes provide easy 2 or point mounting. -9 Siemens / Speedfax Previous folio: -9

10 Sect_0_Speedfax2007 /26/07 5:06 PM Page -10 Heavy Duty Safety Switches SAFETY Indoor Type 1 Outdoor Type R Horsepower Ratings 240V AC 1-Phase, 2-Phase, -Phase, 250 Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* 2-Wire 4-Wire -Wire Volt DC System Rating Number Price $ Std. Pkg. Number Price $ Std. Pkg. Std. Max. Std. Max. Std. Max. 240 Volt Fusible 2-Pole, 2-Fuse, and Solid Neutral (Also used for 2-Pole, 2-Wire Applications) 240 Volt AC/250 Volt DC 000 HF221N HF221NR HF222N HF222NR HF22N HF22NR HF224N HF224NR HF225NH HF225NRH HF225N HF225NR HF226NH HF226NRH HF226N HF226NR HF227N HF227NR HF228N HF228NR Pole, -Fuse, and Solid Neutral (Also used for -Pole, -Wire Applications) 240 Volt AC/250 Volt DC 000 HF21N HF21NR HF22N HF22NR HF2N HF2NR HF24N HF24NR HF25NH HF25NRH HF25N HF25NR HF26NH HF26NRH HF26N HF26NR HF27N HF27NR HF28N HF28NR Volt Fusible 2-Pole, 2-Fuse Type 4/4X Stainless Type 12 Industrial 240 Volt AC/250 Volt DC -Pole, -Fuse 000 HF221S HF221J HF222S HF222J HF22S HF22J HF224S HF224J (Also used for 2-Pole, 2-Wire Applications in A Ratings) 240 Volt AC/250 Volt DC 000 HF21S HF21J HF22S HF22J HF2S HF2J HF24S HF24J HF25S HF25J HF26S HF26J HF27S HF27J Built to order. Allow 2 weeks for delivery. * In pounds (lbs). Height reduced switch (45.25 rather than 56 inches in height) for use with 500MCM or smaller conductors. -10 Dual horsepower ratings: Std.- applies when non-time delay fuses are installed. Max.- applies when timedelay fuses are installed. These switches are UL-listed for application on grounded B-phase systems and are suitable for -phase motor applications. When a neutral is required use a field installed neutral kit. Suitable for use as service entrance equipment. Also rated Type S/R. Discount Schedule HDSS Siemens / Speedfax Previous folio: -10

11 Sect_0_Speedfax2007 /26/07 5:06 PM Page -11 Heavy Duty Safety Switches Horsepower Ratings Indoor Type 1 Outdoor Type R 480V AC 600V AC 1-Phase, -Phase, 1-Phase, -Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* 2-Wire -Wire 2-Wire -Wire Volt Volt System Rating Number Price $ Std. Pkg. Number Price $ Std. Pkg. Std. Max. Std. Max. Std. Max. Std. Max. DC DC 600 Volt Fusible 2-Pole, 2-Fuse 000 HF HF261R HF HF262R HF HF26R HF HF265R HF HF266R HF61S HF61J HF62S HF62J HF6S HF6J HF64S HF64J HF65S HF65J HF66S HF66J HF67S HF67J HF68S HF68J Discount Schedule HDSS 480 Volt AC/600 Volt AC/600 Volt DC -Pole, -Fuse 480 Volt AC/600 Volt AC/250 Volt DC 000 HF HF61R HF61L HF61RL HF HF62R HF62RL HF HF6R HF HF64R HF65H HF65RH HF HF65R HF66H HF66RH HF HF66R HF HF67R HF HF68R Pole, -Fuse and Solid Neutral 480 Volt AC/600 Volt AC/250 Volt DC 000 HF61N HF61NR HF62N HF62NR HF6N HF6NR HF64N HF64NR HF65N HF65NR HF66N HF66NR HF67N HF67NR HF68N HF68NR Volt Fusible (For 2-Pole Applications use outside poles of -Pole Switches) 2-Pole, 2-Fuse -Pole, -Fuse 480 Volt AC/600 Volt AC/600 Volt DC Type 4/4X Stainless Type 12 Industrial 000 HF261S HF261J HF262S HF262J HF26S HF26J HF265S HF265J HF266S HF266J Built to order. Allow 2 weeks for delivery. * In pounds (lbs) A -Pole switches are also rated 600V DC. Height reduced switch (45.25 rather than 56 inches in height) for use with 500MCM or smaller conductors. Use -Pole switch for 200A applications. Dual horsepower ratings: Std.- applies when non-time delay fuses are installed. Max.- applies when timedelay fuses are installed. Suitable for use as service entrance equipment except for 1200 when used on 480 or 600V grounded wye system. Also rated Type S/R. 480 Volt AC/600 Volt AC/250 Volt DC Indicates oversized enclosure (0A switch with 60A lugs in a 60A enclosure or 60A switch with 100A lugs in a 100A enclosure). 600V DC & 600V DC horsepower rating shown requires (2) poles to be connected in series. -11 SAFETY Siemens / Speedfax Previous folio: -11

12 Sect_0_Speedfax2007 /0/07 10:5 AM Page -12 Heavy Duty Safety Switches SAFETY Indoor - Type 1 Outdoor - Type R Horsepower Ratings 240 Volt 480 Volt 600 Volt 250V 600V Ampere Catalog Ship. List Catalog Ship. List System Rating Number Wgt. Price $ Number Wgt. Price $ 1-Phase -Phase 1-Phase -Phase 1-Phase -Phase DC DC 600 Volt Non-Fusible 2-Pole 480 Volt AC / 600 Volt AC / 600 Volt DC 0 HNF HNF261R / HNF HNF262R HNF HNF26R HNF HNF265R HNF HNF266R Pole 480 Volt AC / 600 Volt AC / 250 Volt DC 0 HNF HNF61R / HNF61RL / HNF62H HNF62RH HNF HNF62R HNF62RL HNF HNF6R HNF HNF64R HNF HNF65R HNF HNF66R HNF HNF67R HNF HNF68R Volt Non-Fusible 2-Pole 480 Volt AC / 600 Volt AC / 600 Volt DC Type 4 / 4X Stainless Type 12 Industrial 0 HNF261S HNF261J / HNF262S HNF262J HNF26S HNF26J HNF265S HNF265J HNF266S HNF266J Pole 480 Volt AC / 600 Volt AC / 250 Volt DC 0 HNF61S HNF61J / HNF62SH HNF62JH HNF62S HNF62J HNF6S HNF6J HNF64S HNF64J HNF65S HNF65J HNF66S HNF66J HNF67S HNF67J HNF68S HNF68J Built to order. Allow 2 weeks for delivery. Also rated 600V DC. Compact switch (11.1"H, 6.6"W box less cover and handle). Short circuit withstand rating 100,000 RMS sym. amps. Use -Pole switch for 200A application. Suitable for use as service entrance equipment except for 1200 when used on a 480 or 600V grounded wye system. Also rated type S / R. Indicates oversized enclosure (0A switch in a 60A enclosure or a 60A switch in a 100A enclosure. 600V DC and 600V DC horsepower rating shown requires (2) poles to be connected in series. -12 Discount Schedule HDSS Siemens / Speedfax Previous folio: -12

13 Sect_0_Speedfax2007 /27/07 11:2 AM Page -1 Heavy Duty Safety Switches Type 4/4X & 12 with Viewing Window Description Features 0 600A, -pole 600V max. in fusible and non-fusible versions in Type 4/4X stainless steel and Type 12 enclosures. All allow viewing of visible blade position A also allow viewing of indicating type fuses. Rugged installer-friendly enclosure design features a gasket flange with continuously welded seams Tool-free cover latches Two, three and four point mounting Metal handle with large insulating grip features a positive stop in both ON and OFF position Ground lugs provided as standard Type 12 enclosures are fabricated from galvanized steel and are also rated for R/S outdoor applications Type 4X stainless steel switches (0 200A) are provided with stainless steel interior parts The widest range of accessories available including 200% neutrals, gold plated PLC auxiliary contacts and isolated ground kits SAFETY Maximum Horsepower Ratings Ampere Catalog List Ship. 240V AC 480V AC 600V AC 250V 600V System Rating Number Price $ Weight 1-Phase, 2-Wire -Phase, -Wire -Phase, -Wire -Phase, -Wire DC DC -Pole, -Wire Fusible, Type Volt AC / 250 Volt DC 0 HF61JW / HF62JW HF6JW HF64JW HF65JW HF66JW Pole, -Wire Non-Fusible, Type 12 0 HNF61JW HNF62JW HNF6JW HNF64JW HNF65JW Pole, -Wire Fusible, Type 4X Stainless Steel 600 Volt AC / 250 Volt DC 600 Volt AC / 250 Volt DC 0 HF61SW / HF62SW HF6SW HF64SW HF65SW Pole, -Wire Non-Fusible, Type 4X Stainless Steel 600 Volt AC / 250 Volt DC 0 HNF61SW HNF62SW HNF6SW HNF64SW HNF65SW In pounds (lbs). 200A switches are also rated 600V DC. Maximum HP ratings listed apply only when time delay fuses are used. Also rated S/R for outdoor use. All switches are suitable for use as service entrance equipment. Use outside poles of -pole switch for 2-pole application. 600V DC and 600V DC horsepower rating shown requires (2) poles to be connected in series. Discount Schedule HDSS -1 Siemens / Speedfax Previous folio: -1

14 Sect_0_Speedfax2007 /27/07 11:9 AM Page -14 SAFETY Heavy Duty Safety Switches Type VBII 4 & 6-Pole Heavy Duty Safety Switches Application 4 & 6-pole Switches are commonly used as a disconnecting means for two-speed, two-winding motors. Fused switches provide both over current and short circuit protection. Non-fusible switches normally provide a local disconnection means for twospeed motors which are remote from their motor controller. 4-pole switches are also used in -phase, 4-wire circuits when a switching neutral is required. All 4 & 6-pole switches are service entrance rated. Description 4 & 6-pole switches are available in 0-200A ratings and in both fusible and non-fusible versions. 4-pole switches are supplied with either Type 1 or Type12/R enclosures. 6-pole switches are available with either Type 12/R or Type 4X stainless steel enclosures. Standards UL & CUL listed under file #E4776 Meets UL98 for enclosed switches 4 & 6-Pole switches are suitable for use as service entrance Meets NEMA Standard KS-1 for enclosed switches Meets NEC wire bending space requirements Features Visible blade, double break switching action Highly visible ON/OFF indication Defeatable dual cover interlock Padlock option in OFF position All copper current carrying parts Tangenital knockouts (Type 1, 4-pole switches) HNF66S 4-Pole Type VBII Switches Indoor Type 1 Type 12/R Industrial Horsepower Ratings Amp Catalog List Ship Wt. Catalog List Ship Wt. 240V, 2Ø, 4W 240V Ø 480V, Ø 600V, Ø 250V System Rating Number Price $ (lbs.) Number Price $ (lbs.) Std. Max. Std. Max. Std. Max. Std. Max. DC Fusible 600 Volt AC, 250 Volt DC 4-Pole, 4 Fuse 0 HF HF461J HF HF462J HF HF46J HF HF464J Non-fusible 600 Volt AC, 250 Volt DC 4-Pole 0 HNF HNF461J HNF HNF462J HNF HNF46J HNF HNF464J Pole Type VBII Switches Type 12/R Industrial Type 4X Stainless Steel Horsepower Ratings Amp Catalog List Ship Wt. Catalog List Ship Wt. 240V Ø 480V, Ø 600V, Ø 250V System Rating Number Price $ (lbs.) Number Price $ (lbs.) Std. Max. Std. Max. Std. Max. DC Fusible 600 Volt AC, 250 Volt DC 6-Pole, 6 Fuse 0 HF661J HF661S HF662J HF662S HF66J HF66S HF664J HF664S Non-fusible 600 Volt AC, 250 Volt DC 6-Pole 0 HNF661J HNF661S HNF662J HNF662S HNF66J HNF66S HNF664J HNF664S Built to order. Allow 2 weeks for delivery. Lugs are aluminum alloy as standard. Optional copper body lugs are available. All 4 & 6-pole VBII switches are suitable for use as service equipment when a neutral is installed or equipment ground kit is properly connected. Dual horsepower ratings: Std. applies when non-time-delay fuses are installed. Max. applies when time delay fuses are installed. Fusible switches accept Class H Fuses as the standard. Class R & J fuses can also be installed and increase the rating from 10,000 to 200,000 AIC. For Class J, the load base is moved upward. For Class R fuses, rejection kits are required. Supplied with factory installed ground lugs. -14 Discount Schedule HDSS Siemens / Speedfax Previous folio: -14

15 Sect_0_Speedfax2007 /26/07 5:06 PM Page -15 Heavy Duty Safety Switches Special Application Switches / Interlocked Receptacle Switches Application Receptacle Safety Switches provide cord connection protection of heavy-duty portable equipment (welders, infrared ovens, batch feeders, portable conveyors, assembly line fixtures and tools, refrigerator trucks, etc.) under load or fault conditions. Description Type 12 and 4/4X Receptacle Safety Switches are available with -phase, 4-wire grounded type Crouse-Hinds Arktite 2 receptacle, or Pyle-National pre-wired and mounted with interlock linkage to the switch mechanism. Insertion or removal of the plug is prevented by the interlock linkage while the switch is in the ON position. Receptacle prevents operation of switch if incorrect plug is inserted. Type 4/4X Switches are provided with stainless steel interior parts. All receptacle switches are -pole, -wire plus ground. SAFETY Crouse-Hinds Interlocked Receptacle Switches Type 12 Type 4/4X Shipping Accepts Crouse-Hinds Ampere Catalog List Catalog List Weight Arktite Plug Rating Number Price $ Number Price $ Std. Pkg. Catalog Number 240V Fusible, -Pole, -Wire 0 HF21JCH HF21SCH APJ485 & NPJ HF22JCH HF22SCH APJ6485 & NPJ HF2JCH HF2SCH APJ10487 & NPJ V Fusible, -Pole, -Wire 0 HF61JCH HF61SCH APJ485 & NPJ HF62JCH HF62SCH APJ6485 & NPJ HF6JCH HF6SCH APJ10487 & NPJ V Non-Fusible, -Pole, -Wire 0 HNF61JCH HNF61SCH APJ485 & NPJ HNF62JCH HNF62SCH APJ6485 & NPJ HNF6JCH HNF6SCH APJ10487 & NPJ V Fusible, -Pole, -Wire with Viewing Window 0 HF61JCHW HF61SCHW APJ485 & NPJ HF62JCHW HF62SCHW APJ6485 & NPJ HF6JCHW HF6SCHW APJ10487 & NPJ V Non-Fusible, -Pole, -Wire with Viewing Window 0 HNF61JCHW HNF61SCHW APJ485 & NPJ HNF62JCHW HNF62SCHW APJ6485 & NPJ HNF6JCHW HNF6SCHW APJ10487 & NPJ10487 Pyle-National Interlocked Receptacle Switches -Pole, -Wire Plus Ground Fusible and Non-Fusible Type 12 Type 12 Stainless Steel Shipping Accepts Pyle-National Ampere Rating Voltage Catalog List Catalog List Weight QuelArc Plugs Switch Receptacle Rating Number Price $ Number Price $ Std. Pkg. Plug Catalog Number (F) HF61JPN HF61SPN JPD (N-F) HNF61JPN HNF61SPN (F) HF22JPN (F) HF62JPN HF62SPN JPD (N-F) HNF62JPN HNF62SPN Built to order. Allow 6 8 weeks for delivery. Arktite is a registered trademark of the Crouse- Hinds Company. Plugs are not sold or supplied by Siemens. Indicates plug with maximum diameter cable bushing. QuelArc is a registered trademark of the Pyle- National Company. In pounds (lbs.). Ampere rating of both switch and receptacle. Also rated Type R/S. Enclosure is constructed of Type 04 stainless steel. Discount Schedule HDSS -15 Siemens / Speedfax Previous folio: -15

16 Sect_0_Speedfax2007 /26/07 5:06 PM Page -16 SAFETY Heavy Duty Special Application Safety Switches / Type VBII Non-Metallic Application Siemens Non-Metallic Safety Switches have fiberglass reinforced polyester enclosures which are extremely resistant to a wide range of corrosive atmospheres which can be encountered in waste water treatment plants and certain industrial applications. Description 0-200A, 600V Max, fusible and nonfusible switches are available in Type 4X enclosures. The fiberglass reinforced enclosure allows a wide range of operating temperatures and is supplied with a continuous memory retaining gasket for a superior seal against entry of water, dust and other contaminants. The excellent insulating properties of fiberglass virtually eliminate problems caused by internal condensation. All switches are load break rated and are provided with an equipment ground kit as standard. Class R fuse clip kits and auxiliary switch kits are also available. Ship Horsepower Rating -Phase Weight 240 Volt AC 480 Volt AC 600 Volt AC Ampere Catalog Std.pkg. List Volts Volts System Rating Number (lbs.) Price $ Std. Max. Std. Max. Std. Max. DC DC -Pole, 4-Wire, 240 Volt Fusible, Type 4X 00 HF21NX HF22NX Pole, 4-Wire, 600 Volt AC Fusible, Type 4X 00 HF61NX HF62NX HF6NX HF64NX Pole, -Wire, 600 AC Volt Non-Fusible, Type 4X 00 HNF61X HNF62X HNF6X HNF64X Built to order. Allow 6 8 weeks for delivery. Also used for 240 volt applications. Add L to end of catalog number for switches less line & load lugs with mounting hardware for crimp type or copper body lugs. 200A switches are also rated 600V DC max. 600V DC and 600V DC horsepower rating shown requires (2) poles to be connected in series. Non-Metallic Features 0, 60, 100 and 200 Ampere Switches 600 Volts Fusible 600 Volts Non-Fusible Rated 10,000 AIC with Class H Fuses Rated 200,000 AIC with Class J or R Fuses UL-Listed under File E4776 Horsepower Rated Suitable for use as Service Equipment Quick-make, quick-break mechanism Visible Blade Construction Padlock-off handle feature Field Installable Auxiliary Contacts Field Replaceable Line and Load Bases Factory Installed Ground Lug Supplied as Standard Line Terminal Shields Neutrals Installed as Standard on Fusible Switches -16 Discount Schedule HDSS Siemens / Speedfax Previous folio: -16

17 Sect_0_Speedfax2007 /26/07 5:07 PM Page -17 General and Heavy Duty Safety Switches Accessories HR612 HT6 HN612 Class R Fuse Clip Kits All General Duty and Heavy Duty Switches are field convertible to accept Class R Fuse Clip Kits. The kits prevent the installation of Class H and K fuses (one kit required per -pole switch). Class R Fuse Clip Kits Catalog List Number Price $ Description GSRK A, 240V Kit (GD only) HR A, 240V Kit (HD only) HR A, 600V Kit/60A, 240V Kit HR A, 600V Kit HR A Kit HR A Kit HR A/600A Kit Class J Fusing All 0-600A, 600V and A,240V fusible Heavy Duty Switches are field convertible to accept Class J fuses by moving the load base to a pre-drilled J fuse position. All A, 240V fusible General Duty switches can also be field converted to accept Class J fuses. Class T Fuse Adapter Kits All A, General Duty and A Heavy Duty Switches are field convertible to accept Class T fuses A switches are field convertible to accept Class T fuses by moving the load base to a pre-drilled T fuse position. Class T Fuse Adapter Kits Catalog List Number Price $ Description HT A, 240V Kit HT A, 600V Kit HT A, 240V Kit HT A, 600V Kit TFAK A, 240V Kit TFAK A, 600V Kit TFAK A, 240V Kit Neutral Kits Standard Neutral Kits can be field installed in General and Heavy Duty Switches. Neutral Kits Switch Kit Catalog Ampere Rating Number List Price $ 0 GD W HD, 60 GD HN , 100 HD, 100 GD HN HN & 600 HN & 1200 HN HN % Neutral Kits UL listed 200% Neutrals are available on A Heavy Duty Switches. They are typically used with non-linear transformers or where increased neutral ampacity/lug capacity is required. 200% Neutral Kits Switch Kit Wire Range Ampere Catalog List Line & Load Rating Number Price $ Lugs (Cu/Al) 100 HN (2) #14-1/0 AWG 200 HN (2) #6 AWG-00 Kcmil 400 HN (2) 1/0 AWG-750 Kcmil or (4) 1/0 AWG-250 Kcmil 600 HN (4) 1/0 AWG-750 Kcmil SAFETY Built to order. Allow 6 8 weeks for delivery. One kit per pole required. Discount Schedule HDSS -17 Siemens / Speedfax Previous folio: -17

18 Sect_0_Speedfax2007 /26/07 5:07 PM Page -18 General and Heavy Duty Safety Switches Accessories SAFETY HA16124 Auxiliary Contacts Auxiliary Contacts are available only for Heavy Duty Switches. The auxiliary contacts are available in 1 normally open and 1 normally closed or 2 normally open and 2 normally closed configurations. Siemens offers a PLC Auxiliary Switch (0-200A) that has very low resistance for low voltage and current typical in PLC circuits. All auxiliary contacts make after and break before main switch contacts. Auxiliary Contacts Switch Aux. Switch Kit Ampere Rating Kit Horsepower Rating Ampere Catalog List 125V AC 250V AC 28V DC 125V AC 250V AC 28V DC Rating Number Price $ Max. Max. Max. Max. Max. Max. With 1 NO & 1 NC Isolated Contacts HA /2 / HA /2 /4 With 2 NO & 2 NC Isolated Contacts HA /2 / HA /2 /4 Low Current PLC Type with 1 NO & 1 NC Gold Plated Contacts HA /2 / HA /2 /4 HA26124 Fuse Puller Kits Fuse Puller Kits are field installable in 0-100A Type VBII Heavy Duty Switches (one kit required per -pole switch). Fuse Puller Kits Switch Ampere Fuse Puller Kit Rating Catalog Number List Price $ 00 HP HP HP HP61 Built to order. Allow 6 8 weeks for delivery. -18 Discount Schedule HDSS Siemens / Speedfax Previous folio: -18

19 Sect_0_Speedfax2007 /26/07 5:07 PM Page -19 General and Heavy Duty Safety Switches Accessories Copper Lug Kits Heavy duty switches are UL approved to accept field installed copper lug kits. Copper Lug Kits Switch Copper Lug Ampere Catalog List Rating Number Price $ Description 0 60 HLC (9) Lugs/Kit #14-4 AWG Cu 100 HLC (9) Lugs/Kit #14-1/0 AWG Cu 200 HLC (9) Lugs/Kit #6 AWG-00 Kcmil Cu HLC (1) Lugs/Kit #1/0 AWG-600 Kcmil Cu Equipment Ground Kits Equipment Ground Lug Kits are available for all General and Heavy Duty Switches. They are field installable in Type 1 and Type R Switches and are factory installed as standard in Type 4 / 4X and Type 12 and also in all VBII 4&6-pole Switches. Equipment Ground Kits Switch Ampere Catalog List Number of Wire Range Rating Number Price $ Terminals Per Terminal (Cu/Al) 0A GD GSGK #14-8 AWG GD HG #14-4 AWG HD HG #14-4 AWG 400 & 600 HG #14-2/0 AWG HG #6 AWG-250 Kcmil HLC612 HG26124 SAFETY Isolated Ground Kits Isolated Ground Kits are available on 0-600A Heavy Duty Switches. They are normally used on circuits with a high content of computer or other electronic loading which require a ground which is isolated from the building ground and neutral circuits. The kit includes both isolated and grounded terminals as listed below. Isolated Ground Kits Switch Ampere Catalog List Number of Terminals Wire Range Rating Number Price $ Isolated Grounded Per Terminal (Cu/Al) HG #14-4 AWG HG #14-2/0 AWG Built to order. Allow 6 8 weeks for delivery. Discount Schedule HDSS -19 Siemens / Speedfax Previous folio: -19

20 Sect_0_Speedfax2007 4/4/07 11:1 AM Page -20 General and Heavy Duty Hub and Lug Data SSH150 ECHV00 ECHS200 SL0420 SAFETY Interchangeable Hubs Conduit hubs are available for Type R, 12 and 4 / 4X applications A Type R Switches are provided with a conduit hub provision and a removable hub plate on their top rainshed. Hubs Conduit Size Catalog List (inches) Number Price $ Used On Type R /4 ECHA ECHA A GD Only 1 1/4 ECHA Cover ECHS /4 ECHS ECHS /4 ECHS A GD 1 1/2 ECHS A HD 2 ECHS /2 ECHS /2 ECHV ECHV /2 ECHV A 4 ECHV Type 4/4X /4 SSH SSH /4 SSH A 1 1/2 SSH SSH Note: 0 thru 200A. Type R Switches have removable hub plates on rainshed. 400A and larger Type R Switches have no provisions for mounting hubs. Drill or punch hole in the field to accommodate hub size desired. Built to order. Allow 2- weeks for delivery. Hubs suitable for R Switches. Also suitable for Type 12 applications. Neutral Barrier kits are required on 0-100A switch only and only with 1-Phase / W or -Phase / 4W loads. Compression Lugs mounting kits are required on A switches only. Provides mounting for a single line or load lug. Provides mounting for (2) compression lugs per phase on line or load. -20 Compression Lug Mounting & Neutral Barrier Kit All Heavy Duty Switches are field convertible for (Crimp) type lugs. When compression lugs are required for 0-100A switches, a neutral barrier kit is required for 1-Phase, W or -Phase, 4W applications. When compression lugs are required on A switches, lug mounting kits are required. Compression Lug Mounting and Neutral Barrier Kits Switch Ampere Catalog List Rating Number Price $ Kit Description 0 HCL Neutral Barrier Kit 60 & 100 HCL Neutral Barrier Kit 400 HCL Pole, Compression Lug Mounting Kit Pole, Compression HCL65678 & Lug Mounting Kit Pole, Compression HCL65678 & Lug Mounting Kit Lugs 0 & 60A Switches are suitable for use with 60 or 75 C wire A are suitable for use with 75 C rated wire. Wire Ranges (Line, Load and Standard Neutral) Line lugs are UL approved to accept #14-6 CU/Al cable. Max. wire size for height reduced switches is 500 kcmil (Cu/Al). All but 60A GD & Compact HD NF switches are also UL approved for #2 Cu/Al conductors. Multiple Padlock Accessory A tamper-proof device to provide for multiple padlocking to meet OSHA or plant requirements. Accepts up to 6 padlocks. Catalog number SL0420. Standard Carton-12. List Price $ Kirk-Key Interlocks Kirk-Key Interlocks can be factoryinstalled only on Type VBII Heavy Duty and Double Throw Safety Switches. Interlocks are used to prevent the operator from making an unauthorized operation. The interlock system is a simple method of applying key interlocks to safety switches so as to require operation in a predetermined sequence. List Price $ Before consulting the factory, the following information is required: User name and address Key number from lock assemblies on any existing locks to be interlocked with Complete locking scheme Consult factory for delivery. Switch Wire Range with Ampere Wire Bending Space Rating Per NEC Requirements Lug Wire Range 0GD #14-8 AWG (Cu/AI) #14-8 AWG (Cu/Al) 0HD #14-6 AWG (Cu/AI) #14-2 AWG (Cu/Al) 60 #14- AWG (Cu/AI) #14-2 AWG (Cu/Al) 100 #14-1/0 AWG (Cu/Al) #14-1/0 AWG (Cu/Al) 200 #6 AWG-250 Kcmil (Cu/Al) #6 AWG-00 Kcmil (Cu/Al) 400 1/0 AWG-750 Kcmil (Cu/Al) or (1) 1/0 AWG-750 Kcmil (Cu/Al) or (2) 1/0 AWG-250 Kcmil (Cu/Al) (2) 1/0 AWG-250 Kcmil (Cu/Al) 600 (2) 1/0 AWG-750 Kcmil (Cu/Al) or (2) 1/0 AWG-750 Kcmil (Cu/Al) or (4) 1/0-250 Kcmil (Cu/Al) (4) 1/0 AWG-250 Kcmil (Cu/Al) 800 () 1/0 AWG-750 Kcmil (Cu/Al) Line Load or () 1/0 AWG-750 Kcmil (Cu/Al) Line Load or (6) 1/0 AWG-250 Kcmil (Cu/Al) (6) 1/0 AWG-250 Kcmil (Cu/Al) (4) 1/0 AWG-750 Kcmil (Cu/Al) neutral (4) 1/0 AWG-750 Kcmil (Cu/Al) neutral 1200 (4) /0 AWG-750 Kcmil (Cu/Al) Line Load (4) 1/0 AWG-750 Kcmil (Cu/Al) Line Load (4) 1/0 AWG-750 Kcmil (Cu/Al) neutral (4) 1/0 AWG-750 Kcmil (Cu/Al) neutral All 200A Heavy Duty Switches have a wire range & wire bending space for (1) #6-00 Kcmil (Cu/Al). Also for 0A oversized heavy duty switches. Also for 60A oversized heavy duty switches. Discount Schedule HDSS & RESI Siemens / Speedfax Previous folio: -20

21 Sect_0_Speedfax2007 /26/07 5:07 PM Page -21 General and Heavy Duty Safety Switches Safety Switch Dimensions (Inches)* & Shipping Weights Dimensions Height Width Depth With With With With Knockout Shipping Catalog Box Door Rain Shed Box Handle Box Handle Diagram Weight Number A B C D E F G (lbs.) GF221N S1 5 (10) GF221NR S 5 (10) GF222N S6 14 GF222NR S8 14 GF22N S10 2 GF22NR S11 24 GF224N S12 47 GF224NR S1 48 GF225N S14 15 GF225NH S GF225NR S GF225NRH S15 10 GF226N S GF226NH S14 1 GF226NR S GF226NRH S15 15 GF21N S2 24 (5) GF21NR S4 24 (5) GF22N S6 15 GF22NR S8 15 GF2N S10 25 GF2NR S11 25 GF24N S12 49 GF24NR S1 50 GF25N S GF25NH S14 16 GF25NR S GF25NRH S15 18 GF26N S GF26NH S14 18 GF26NR S GF26NRH S GNF S2 24 (5) GNF21R S4 24 (5) GNF S7 12 GNF22R S9 1 GNF S10 2 GNF2R S11 24 GNF S12 46 GNF24R S1 47 GNF S GNF S HF221J HF221N S6 12 HF221NR S8 1 HF221S HF222J HF222N S16 18 HF222NR S17 19 HF222S HF22J HF22N S10 2 HF22NR S11 24 SAFETY *For inches / millimeters conversion, multiply inches by Knocks not provided on Type 4 / 4X and 12 or in 800 & 1200A switches. -21 Siemens / Speedfax Previous folio: -21

22 Sect_0_Speedfax2007 /26/07 5:07 PM Page -22 SAFETY General and Heavy Duty Safety Switches Safety Switch Dimensions (Inches)* & Shipping Weights Dimensions Height Width Depth With With With With Knockout Shipping Catalog Box Door Rain Shed Box Handle Box Handle Diagram Weight Number A B C D E F G (lbs.) HF22S HF224J HF224N S12 47 HF224NR S1 48 HF224S HF225N S14 15 HF225NH S HF225NR S HF225NRH S15 11 HF226N S HF226NH S14 1 HF226NR S HF226NRH S15 15 HF227N HF227NR HF228N HF228NR HF S HF265J HF265R S HF265S HF S HF266J HF266R S HF266S HF21J HF21N S6 14 HF21NR S8 15 HF21S HF22J HF22N S16 19 HF22NR S17 20 HF22S HF2J HF2N S10 25 HF2NR S11 26 HF2S HF24J HF24N S12 49 HF24NR S1 50 HF24S HF25J HF25N S HF25NH S14 17 HF25NR S HF25NRH S15 18 HF25S HF26J HF26N S HF26NH S14 19 HF26NR S HF26NRH S HF26S HF27J HF27N HF27NR HF27S HF28N HF28NR HF S6 14 HF61J, JW HF61L S16 19 HF61N S6 14 HF61NR S8 15 HF61R S8 15 HF61RL S17 20 HF61S, SW HF S16 19 *For inches / millimeters conversion, multiply inches by Knocks not provided on Type 4 / 4X and 12 or in 800 & 1200A switches. -22 Siemens / Speedfax Previous folio: -22

23 Sect_0_Speedfax2007 /27/07 11:40 AM Page -2 General and Heavy Duty Safety Switches Safety Switch Dimensions (Inches)* & Shipping Weights Dimensions Height Width Depth With With With With Knockout Shipping Catalog Box Door Rain Shed Box Handle Box Handle Diagram Weight Number A B C D E F G (lbs.) HF62J, JW HF62N S16 19 HF62NR S17 20 HF62R S17 20 HF62RL S11 25 HF62S, SW HF S10 24 HF6J, JW HF6N S10 25 HF6NR S11 26 HF6R S11 25 HF6S HF S12 48 HF64J, JW HF64N S12 49 HF64NR S1 48 HF64R S1 49 HF64S, SW HF S HF65H S14 16 HF65J, JW HF65N S HF65NR S HF65R S HF65RH S15 17 HF65S, SW HF S HF66H S14 18 HF66J, JW HF66N S HF66NR S HF66R S HF66RH S HF66S HF HF67J HF67N HF67NR HF67R HF67S HF68, J, S HF68N HF68NR HF68R HNF S HNF265J HNF265R S HNF265S HNF S HNF266J HNF266R S HNF266S HNF S7 12 HNF61J, JW HNF61R S9 1 HNF61RL S17 20 HNF61S, SW HNF S16 18 HNF62J, JW HNF62R S17 19 HNF62RL S11 24 HNF62S, SW HNF S10 2 HNF6J, JW HNF6R S11 24 HNF6S, SW HNF S12 46 HNF64J, JW HNF64R S1 47 HNF64S, SW *For inches / millimeters conversion, multiply inches by Knocks not provided on Type 4 / 4X and 12 or in 800 & 1200A switches. -2 SAFETY Siemens / Speedfax Previous folio: -2

24 Sect_0_Speedfax2007 /26/07 5:07 PM Page -24 A A A A A SAFETY General and Heavy Duty Safety Switches Safety Switch Dimensions (Inches)* & Shipping Weights Dimensions Height Width Depth With With With With Knockout Shipping Catalog Box Door Rain Shed Box Handle Box Handle Diagram Weight Number A B C D E F G (lbs.) HNF S HNF65J, JW HNF65R S HNF65S, SW HNF S HNF66J, S HNF66R S HNF67, J HNF67R HNF67S HNF68, J, S HNF68R LF111N S2 5 (10) LF111NR S 5 (10) LF211N S1 5 (10) LF211NR S 5 (10) LNF222R S5 5 (10) Type 1 or R 0A GD Type 1 or R A GD, 0-200A HD Type VBII Type 4/4X or A HD Type VBII E G E G B or C B or C B or C D E F G D F D F Type 1 or R A Type VBII (GD & HD) E G Type 4/4X or A HD Type VBII E G B or C B or C D F D F *For inches / millimeters conversion, multiply inches by Knocks not provided on Type 4 / 4X and 12 or in 800 & 1200A switches. -24 Siemens / Speedfax Previous folio: -24

25 Sect_0_Speedfax2007 /26/07 5:08 PM Page -25 General and Heavy Duty Safety Switches Type 1 & R Enclosures Knockout Diagrams Removable plate covering HA Type Hub opening (Max Conduit) S1 Embossed.25 in. mounting holes (4 places) 4 K.O.'s for Conduit in. S2 Embossed.25 in. mounting holes (4 places) 2 K.O.'s for Conduit in. S Embossed.25 in. mounting holes ( places) 2 K.O.'s for Conduit in. 7 K.O.'s for Conduit in. Removable plate covering HA Type Hub opening (Max Conduit) 10 K.O.'s for Conduit in. K.O.'s for Conduit in. 10 K.O.'s For Conduit 0.50, 0.75, 1 in. 4 K.O.'s for Conduit 0.75, 1 in. SAFETY S4 Embossed.25 in. mounting holes ( places) S5 Embossed.25 in. mounting holes ( places) S6 8 K.O.'s for Conduit 0.50, 0.75, 1 in. 2 K.O.'s for Conduit in. 4 K.O.'s for Conduit in. 4 K.O.'s for Conduit 0.75, 1 in. 2 K.O.'s for Conduit in. K.O.'s for Conduit in. Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) dia. K.O's Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S7 S8 S dia. K.O's 2 K.O.'s for Conduit 0.75, 1 in. 5 K.O.'s for Conduit 0.50, 0.75, 1 in dia. K.O. Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) 2 K.O.'s for Conduit 0.75, 1 in. 5 K.O.'s for Conduit 0.50, 0.75, 1 in dia. K.O. S10 S11 S dia. K.O. 4 K.O.'s for Conduit 0.75, 1, 1.25, 1.50 in. 10 K.O.'s for Conduit 1, 1.25, 1.50, 2 in dia. K.O. 5 K.O.'s for Conduit 1, 1.25, 1.50, 2 in. 2 K.O.'s for Conduit 0.75, 1, 1.25, 1.50 in dia. K.O dia. K.O dia. K.O. 14 K.O.'s for Conduit 1.25, 1.50, 2.00, 2.50 in dia. K.O. *For inches / millimeters conversion, multiply inches by Siemens / Speedfax Previous folio: -25

26 Sect_0_Speedfax2007 /26/07 5:08 PM Page -26 General and Heavy Duty Safety Switches Type 1 & R Enclosures Knockout Diagrams Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S1 S14 S15 1, 0.25, dia. K.O 7 K.O.'s for Conduit 1.25, 1.50, 2.00, 2.50 in dia K.O. 8 K.O.'s for Conduit 2.00, 2.50,.00,.50 in , 0.75 dia. K.O.'s 4 K.O.'s for Conduit 2.00, 2.50,.00,.50 in , 0.75 dia. K.O.'s SAFETY Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S16 S dia. K.O dia. K.O. 14 K.O.'s for Conduit 0.50, 0.75, 1, 1.25 in dia. K.O. 7 K.O.'s for Conduit 0.50, 0.75, 1, 1.25 in dia. K.O. *For inches / millimeters conversion, multiply inches by Siemens / Speedfax Previous folio: -26

27 Sect_0_Speedfax2007 /26/07 5:08 PM Page -27 Special Application Safety Switches Dimension Drawings Non-Metallic Dimensions 4 X 0.50 (12.70) W C F Non-Metallic G H A E B J D SAFETY Catalog Dimensions (Inches) Non-Metallic Number H W D A B C E F G J HF21NX HF22NX HF61NX HF62NX HF6NX HF64NX HNF61X HNF62X HNF6X HNF64X VBII Interlocked Receptacle Switches Ampere Dimensions (Inches) Rating A B C D E F G Cr-H Type Fusible (240 & 600V) Cr-H Type Non-Fusible (600V max.) Pyle-National Type Fusible (240 & 600V) Pyle-National Type Non-Fusible (600V max.) B C D F E A G *For inches / millimeters conversion, multiply inches by Dimensions also apply to L suffix switches (less lugs). -27 Siemens / Speedfax Previous folio: -27

28 Sect_0_Speedfax2007 /26/07 5:08 PM Page -28 SAFETY Special Application Safety Switches Dimension Drawings 4-Pole & 6-Pole 4 & 6-Pole Safety Switch Dimensions Inches (mm) Enclosure Mounting Catalog Number A B C D E F Figure 1, 4-Pole Fusible and Non-fusible, Type 1 HNF (622) 9.5 (242) 6.09 (155) (48) 6.75 (171) (7) HF (740) 9.5 (242) 6.09 (155) 2.50 (597) 6.75 (171) (7) HNF (62) (292) 6.09 (155) (48) 9.8 (28) (7) HF462.5 (852) (292) 6.09 (155) (699) 9.8 (28) (7) HNF (702) (09) 6.09 (155) 19.6 (492) 8.00 (20) (7) HF (926) (09) 6.09 (155) (714) 8.00 (20) (7) HNF (914) (486) 6.42 (16) 0.88 (784) (81) 0.44 (11) HF (1257) (486) 6.42 (16) (110) (81) 0.44 (11) Figure 2, 4 & 6-Pole Fusible Type 12/R and 4X HF461J, HF661J, (622) 9.5 (242) 6.48 (165) 1.65 (804) 5.47 (19) 0.27 (7) HF661S HF462J, HF662J,.5 (852) (292) 6.48 (165) 5.69 (907) 8.00 (20) 0.27 (7) HF662S HF46J, HF66J, 6.44 (926) (09) 6.48 (165) 8.67 (982) 8.47 (215) 0.27 (7) HF66S HF464J, HF664J, (1257) (486) 6.78 (172) (112) 1.44 (41) 0. (8) HF664S Figure 2, 4 & 6-Pole Non-fusible Type 12/R and 4X HNF461J, HNF661J, (622) 9.5 (242) 6.48 (165) (667) 5.47 (19) 0.27 (7) HNF661S HNF462J, HNF662J, (62) (292) 6.48 (165) 27.0 (687) 8.00 (20) 0.27 (7) HNF662S HNF46J, HNF66J, (700) (09) 6.48 (165) (756) 8.47 (215) 0.27 (7) HNF66S HNF464J, HNF664J, 6.00 (914) (486) 6.78 (172) 8.16 (969) 1.44 (41) 0. (8) HNF664S Dimensions Figure 1: Type 1 Figure 2 : Type 12/R and 4X -28 Siemens / Speedfax Previous folio: -28

29 Sect_0_Speedfax2007 /26/07 5:08 PM Page -29 Special Application Safety Switches Dimension Drawings Double Throw Description Double throw switches are intended to transfer loads from one power source to another. All 2 & -pole double throw switches are suitable for use as service equipment. All are UL Listed and both horsepower and load break rated. Switches are rated for use on systems up to 10,000A when protected with Class H fuses or 100,000A when protected with Class R or Class T fuses. They can also be used to connect a single source of power to either of two loads. In this application it is necessary to field modify Double Throw Switches fusible switches so that the fuses are on the load side of the switching mechanism. A cover interlock is provided on all ampere ratings. The operating handle may be padlocked in the off position. Fuse Capabilities of Fusible DTF Switches Amp Rating Fuse Type H R T J 0 & 60A, 240V Std Yes (kit) No No 0 & 60A, 600V Std Yes (kit) No Yes 100 & 200A Std Yes (kit) Yes (kit) Yes 400 & 600A (DTF) No No Yes Std Type 1 Indoor Type R Outdoor Type 12/R Industrial Type 4X Stainless Steel Number Catalog List Catalog List Catalog List Catalog List System Voltage of Poles Amps Number Price $ Number Price $ Number Price $ Number Price $ Heavy Duty Fusible (0-200A) with Class H fuse spacings DTF DTF224R DTF DTF21R Volt AC 60 DTF DTF22R or 100 DTF DTF2R DTF DTF24R Volt DC 400 DTF FR25DTK DTF FR26DTK DTF DTF Volt AC, 100 DTF DTF6R F5SSDTK DTF DTF64R F54SSDTK Volt DC 400 DTF FR55DTK F55SSDTK SAFETY 0 DTNF DTNF DTNF DTNF DTNF224R DTNF DTNF225R Volt AC or 0 DTNF Volt DC 60 DTNF DTNF DTNF2R DTNF DTNF24R DTNF DTNF DTNF DTNF DTNF61R DTNF61J DTNF61S DTNF DTNF62R DTNF62J DTNF62S DTNF DTNF6R DTNF6J DTNF6S DTNF DTNF64R DTNF64J DTNF64S DTNF DTNF65R NF55HDTK NF55SSDTK DTNF DTNF66R Volt AC, 800 DTNF DTNF67R or 1200 DTNF DTNF68R Volt DC 0 NFR451DTK NFR452DTK NFR45DTK NF454DTK NFR454DTK NF454SSDTK NF455DTK NFR455DTK NF456DTK NFR456DTK NF457DTK NFR457DTK General Duty Non-Fusible Type R Outdoor Type R Outdoor Less Neutral With Neutral 100 DTGNF22R DTGNF22NR DTGNF224R DTGNF224NR Volt AC 100 DTGNF2R DTGNF2NR DTGNF24R DTGNF24NR Built to order. Allow 4 weeks for delivery. Use HS Type hubs for 0 200A switches. 400A and larger switches do not have hub provisions. All Heavy Duty double throw switches with a catalog number starting with DT are rated 200,000 AIC max. when protected by Class R, J or T fuses. Fuse ampere rating must not exceed switch ampere rating. Move load base. Will accept class T Fuses only. 4-pole switches are not approved for service entrance. Discount Schedule HDSS -29 Siemens / Speedfax Previous folio: -29

General and Heavy Duty Safety Switches

General and Heavy Duty Safety Switches General and Heavy Duty Safety es Accessories 10/01/13 Selection 4 Class R Fuse Clip Kits All General Duty and Heavy Duty es are field convertible to accept Class R Fuse Clip Kits. The kits prevent the

More information

Switches. Safety and Disconnect Switches. Heavy Duty Safety Switch Standards and Ratings

Switches. Safety and Disconnect Switches. Heavy Duty Safety Switch Standards and Ratings Safety and Disconnect es Contents Pages Heavy Duty Safety es Safety Features........................18/2 Selection, 240V Fusible........................18/3 Selection, 600V Fusible........................18/4

More information

Product Guide. NEMA pump controls.

Product Guide. NEMA pump controls. Product Guide NEMA pump controls www.usa.siemens.com/controls Class 87 full voltage pump controller with fusible disconnect switch and standard features Class 87 NEMA full starter pump control panels Product

More information

Safety Switches. c o n t e n t s SPEEDFAX TM 2017

Safety Switches. c o n t e n t s SPEEDFAX TM 2017 Safety Switches SPEEDFAX TM 2017 Section General Duty Switch Heavy Duty Switch Window Switch c o n t e n t s Safety Switch Guide Form Specifications -2 Feature Comparison -3 Enclosure Types - ing System

More information

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R Safety Switches Heavy Duty 240 Volt Indoor Type Outdoor Type 3R Horsepower Ratings 240V AC Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* 2 Wire 4 Wire 3 Wire System Rating

More information

Safety and Disconnect Switches

Safety and Disconnect Switches Safety and Disconnect es Industrial Controls Product 2017 Section c o n t e n t s Heavy Duty Enclosed Safety es Features and Benefits /2 240V Selection /3 600V Selection /4 - /5 es with Viewing Window

More information

Switches Safety and Disconnect Switches

Switches Safety and Disconnect Switches es Safety and Disconnect es Contents Pages Contents Pages Heavy Duty Enclosed Safety es Features and Benefits.......................... 18/2 240V Selection............................... 18/3 600V Selection..........................

More information

POWER PRODUCT Safety Switches. Contents - Safety Switches 3 SAFETY SWITCHES

POWER PRODUCT Safety Switches. Contents - Safety Switches 3 SAFETY SWITCHES POWER PRODUCT Safety es ID Heavy Duty Contents - Safety es Air Conditioning Disconnects -2 Safety Guide Form Specifications -4 Feature Comparison -6 Enclosure Types -7 Light Duty switches - -8 SE and ID

More information

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle Features 30-600A, 600VAC and DC ratings UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 15852 Visible blade quick make and break switching action Panel and Flange mounted assemblies

More information

GHN424NW HHN426N HUN361AW

GHN424NW HHN426N HUN361AW GHN424NW HHN426N HUN61AW Passed The Test of Time All Murray safety switches have passed rigid testing requirements to assure reliable performance. In addition to tests designed and conducted during the

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Type VBII Visible Blade Disconnect Switches

Type VBII Visible Blade Disconnect Switches Type VBII Visible Blade Disconnect es Product Guide Siemens Type VBII visible blade disconnect switches meet either UL98 or UL1741 requirements and can be used in either service entrance or branch circuit

More information

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection Table of Contents Introduction...2 Safety Switches...4 Symbols...6 Need for Circuit Protection...8 Fuses... 13 Fuse Ratings and Classifications... 16 Enclosures... 19 Switch Design...24 Safety Switch Ratings...29

More information

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install Midwest Electric Products Safety Switches Rugged, reliable and easy to install Midwest Safety Switches Features Midwest Electric Products offers a wide variety of general duty and heavy duty safety switches,

More information

1.1. Switching Devices

1.1. Switching Devices . Switching Devices Six-Pole Motor Circuit Contents Description Page Product Overview......................... V2-T-2 General Duty............................. V2-T-24 Heavy-Duty..............................

More information

General and Heavy Duty Safety Switches Accessories

General and Heavy Duty Safety Switches Accessories eneral and Heavy uty Safety es Accessies Selection HR612 HT63 HN612 lass R use lip Kits All eneral uty and Heavy uty es are field convertible to accept lass R use lip Kits. The kits prevent the installation

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection Table of Contents Introduction...2 Siemens Safety Switches...4 Switch Symbols...7 Need for Circuit Protection...9 Fuses... 17 Fuse Ratings and Classifications...21 Enclosures...24 Switch Design...31 Safety

More information

Safety Switch. Type VBII. cross-reference GUIDE

Safety Switch. Type VBII. cross-reference GUIDE Safety Switch Type VBII cross-reference GUIDE General Duty 240 Volt, Type 1 (Indoor) 2-Pole, 2-Wire, Fusible 2-Pole, 3-Wire, Fusible 3-Pole, 3-Wire, Fusible 3-Pole, 4-Wire, Fusible 30 Use 60 Use Use Use

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch . Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description

More information

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Arktite Heavy Duty Circuit Breaking Plugs and Connectors Arktite Heavy Duty Circuit Breaking Plugs and Connectors 60 A, 600 VAC/250 VDC, 50**-400 hertz Dimensions Page 968 1P Plug Connector Mating APJ Plugs Mating APR Connectors Style 1 Description Cat. # Dia.

More information

Safety Alert: Square D Safety Switches

Safety Alert: Square D Safety Switches Safety Alert: Square D Safety Switches Be Sure to Inspect Your Installed Units for Defects Schneider Electric has issued an offer safety alert on the Square D safety switch due to electrical shock hazard

More information

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Enclosed Rotary Switch Product Specification Sheets Table of Contents Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX

More information

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com AR331 30 Amp Pin & Sleeve Recpt 3-W 3-P 250VDC/600vac Cooper Crouse-Hinds Catalog Number

More information

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW preliminary information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. www.usa.siemens.com/controls

More information

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry. www.usa.siemens.com/controls NEA Pump Controls Class 82 slim line NEA pump controller for the agricultural industry Answers for industry. Class 82 Slim Line NEA Pump Controller Typical applications include:

More information

Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $

Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $ January 1 Vol. 1, ef. No. [0247] eavy uty, Fusible, - 361FK NEMA 12 Enclosure Industrial ust-tight NEMA 4 Enclosure atertight, Painted Steel Enclosure Corrosion esistant, Stainless Steel 2-Pole 40V AC

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. usa.siemens.com/controls

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch Double-Throw, continued Ampere Rating Catalog Number Selection Safety Switch Catalog Number Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA X 30 N/A N/A N/A N/A

More information

Safety Switches Section 4

Safety Switches Section 4 Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG... 4-5 eavy Duty, Type T...4-7 eavy Duty Stainless Steel, Type T... 4-11 Mill Duty, Type T...4-13 Double Throw Switches, Type TC, TDT...4-15

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles 1P Arktite Heavy Duty Circuit Breaking s and Receptacles Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas 1P Arktite Heavy Duty Circuit Breaking s and s Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically operated

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

IN2 Enclosed Switches and Circuit Breakers

IN2 Enclosed Switches and Circuit Breakers Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Enclosed Switches and Circuit Breakers Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles Compatible with UL 1686 C1 Pin & Sleeve Devices Safer. Easier. Better. MENNEKES Non-Metallic MSR Switched and Interlocked

More information

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine eavy Industrial/ Marine Benefits builds a variety of benefits into one plug, receptacle and interlock system for your application. Safety Waterproof construction: standard neoprene O ringed interior components

More information

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

1. Division 26 Section Elevator Shunt-Trip Fused Disconnect Switches. SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Product Guide. enclosed NEMA STARTERS

Product Guide. enclosed NEMA STARTERS Product Guide enclosed NEMA STARTERS The Right Choice for Applications that Demand the Best. Siemens NEMA Combination and Non- Combination Starters for Industrial and Construction Applications Rugged,

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not

More information

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753 Depth x  Width x 2.375 Height 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 7842 40A 600V 2P Switch Pass & Seymour/Legrand Catalog Number 7842 Manufacturer Pass & Seymour/Legrand Weight per unit

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Product guide. Enclosed NEMA starters. usa.siemens.com/controls Product guide Enclosed NEMA starters usa.siemens.com/controls The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction

More information

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 ARL2042 Receptacle Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Descriptions

More information

1.1. Switching Devices. Safety Switches

1.1. Switching Devices. Safety Switches . Catalog Number Eaton General Electric Siemens Square D Fusible, Three-Pole, Four-Wire, 20 Vac, NEMA 3R 30 DH32NRK TH32R HF32NR H32NRB 60 DH322NRK TH322R HF322NR H322NRB 00 DH323NRK TH323R HF323NR H323NRB

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

Product guide. Enclosed NEMA starters. Answers for industry.

Product guide. Enclosed NEMA starters. Answers for industry. Product guide Enclosed NEMA starters Answers for industry. The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction applications

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles P Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable

More information

Section 4. Safety Switches.

Section 4. Safety Switches. Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG...4-5 eavy Duty, Type T...4-7 eavy Duty Stainless Steel, Type T...4-11 Mill Duty, Type T...4-13 Double Throw Switches, Type TC, TDT...4-15

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Boxes C  wide, 5 3 4 deep. C  wide, 5 3 4 deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3. Circuit Breaker / Column Type Type C1 240 Volts AC Mains Branch UL Short Circuit Rating 200,000 IR Branch Breaker Symmetrical Interrupting Rating Based on Underwriters Test Procedure Type C2 480Y/277 Volts

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

Instructions for Installation, Operation and Maintenance of: WSRD Interlocked Receptacles 30, 60 & 100 Ampere 331114-1 INSTRUCTION SHEET Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere Read instructions carefully and with full understanding for safe

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically operated devices

More information

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS DIVISION 26 ELECTRICAL SECTION 26 28 19 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install circuit breakers in switchboards, distribution panelboards, and separate enclosures for overcurrent protection

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Selection Guide Contents Descriptions Page General Information Features and Benefits 2-3 Product Illustrations General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Heavy Duty Safety

More information

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 APJ10487 100 Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac Cooper Crouse-Hinds Catalog Number Manufacturer Description

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary

More information

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION Specification Number: 26 24 13.20 Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION 26 24 13.20 SWITCHBOARDS (Long) Main Disconnect Group Mounted Fusible

More information

NEMA Contactors & Starters (Freedom)

NEMA Contactors & Starters (Freedom) Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38 Series 7 Motor (to 100A)...2 Series 7 Enclosed (to 100A)...14 Technical Information...18 Dimensions...22 Series 7 (to 315A)...29 Technical Information...36 Dimensions...38 Series 10 Fusible and Non-Fusible...45

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Solar Combiner Solutions

Solar Combiner Solutions Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically operated devices

More information

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch Page 1 2015 Kinked roof prevents standing moisture Glass reinforced barriers meet NEMA GPO-3 Standards 0.625" diameter copper ground bar Elliott air-insulated bushings accept IEEE Standard inserts and

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

Solar Combiner Solutions

Solar Combiner Solutions Solar Combiner Solutions Providing combiners and disconnects that offer superior resistance and durability from harsh weather and abusive solar environments Solar Technology Leading the way in Solar Technology

More information

Section 4. Safety Switches.

Section 4. Safety Switches. Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG... 4-5 eavy Duty, Type T...4-7 eavy Duty Stainless Steel, Type T... 4-11 Mill Duty, Type T...4-13 Double Throw Switches, Type TC, TDT...4-15

More information

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: 1. For commercial and industrial installation, purchased and installed by the customer. 2. To enclose 600 volt insulation class instrument transformers

More information

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses Page 1 2015 Heavy duty 11-gauge steel enclosure is all-welded construction for long life Corrosion proof nameplate is located to provide easy access for the operator Glass reinforced barriers meet NEMA

More information

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 3150A 30A 3000A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

SECTION. Watertight & Dust-Tight Plugs & Connectors

SECTION. Watertight & Dust-Tight Plugs & Connectors SECTION Watertight & ust-tight Wetguard Product Line Section Contents LIFETIME Wetguard Plugs, Connectors & Straight Blade 2-Pole 3-Wire 2-Pole 3-Wire 3-Pole 4-Wire 3-Pole 3-Wire Non- 4-Pole 4-Wire Non-

More information

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Powergrid Solution s Metal Enclosed Switchgear has many different customizable options and configurations. Customers

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information