Catalog Number Description

Size: px
Start display at page:

Download "Catalog Number Description"

Transcription

1 Description Enclosed Safety Switches Segment Character Description D N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double throw pole poles Blades Switchable Poles poles 4 4 poles 6 6 poles Vac (plug fuse) Voltage Rating 40 Vac Vac 0 A 60 A 0 A 4 0 A Ampere Rating 400 A A A 8 A Factory-installed neutral (neutrals are field-installed on most general duty, heavy duty, N and double throw safety switches). No suffix NEMA Type A NEMA Type K AWK NEMA Type (without K.O.) DF NEMA Type 4X Fiberglass reinforced polyester Enclosure DS NEMA Types 4, 4X, and (Type 04 stainless steel) DX NEMA Type 4X Krydon Factory Modifications For dc ratings, see the latest catalog listing. R NEMA Type R RB NEMA Type R (bolt-on hub provision) SS NEMA Types 4, 4X, and (Type 6 stainless steel) CLR Class R fuse kit EI or EI Electrical interlock kit GL Equipment ground lugs GLC Equipment ground lug, copper only KI, KI or KIKI or Key interlocks LK Compression lugs (800 and A only) NP Phenolic legend plate PB Push buttons, pilot lights, selector switches. Customer must provide catalog number of control device to be installed SLC Copper lugs (0 600 A) SP Special paint colors SPLO Lock-on provision VW Viewing window WA Appleton interlocked receptacle WC Crouse-Hinds Arktite interlocked receptacle WH Hubbellock interlocked receptacle 09 Schneider Electric /09

2 09 Schneider Electric 6 /09 Table 4: Accessories for Current Series Heavy Duty Safety Switches Series Electrical Interlock ( Contact) Electrical Interlocks ( Contacts) Class R Kits Solid (Al/Cu) Solid (Cu Only) Grounding Kit (Al) Grounding Kit (Cu) Fuse Puller Receptacle Plugs H466 H60XFA H66AWK H66DS EK 0 HRK4060 RFK HRK 0SNA GTK06 PKOGTC GTK06C PKOGTC H664DS H664AWK HU6 HU6AWK EK EK 0 0 HRK HRK C C PKOGTC PKOGTC PKOGTC PKOGTC HU6DS HU6R HU66 HU66AWK C C C C PKOGTC PKOGTC PKOGTC PKOGTC HU66DS HU66R HU67 HU67AWK C C C C PKOGTC PKOGTC PKOGTC PKOGTC HU67R HU68 HU68AWK HU68R H800SN H800SN HSN HSN PKOGTA7 PKOGTA7 PKOGTA8 PKOGTA8 HU6 HU6A HU6AWA HU6AWC EIK0 EIK0 EIK0 EIK0 SN0 SN0 SN0C SN0C GTK0 GTK0 GTK0C GTK0C ACP04BC APJ48 HU6AWK HU6DF HU6DS HU6DSWA EIK0 9999TC EK00 EK00 EIK0 9999TC EK00 EK00 SN0 SN0C C C GTK0 PKGTA GTK0C PKOGTC ACP04BC HU6DSWC HU6DX HU6RB HU6WA EK TC EIK0 EK TC EIK0 SN0 C SN0C GTK0 GTK0C APJ48 ACP04BC HU6WC HU6 HU6A HU6AWA C C C C GTK06 GTK06 GTK06 GTK06C GTK06C GTK06C APJ48 ACP604BC HU6AWC HU6AWH HU6AWK HU6DF 9999TC 9999TC C C C C GTK06 GTK06 GTK06 GTK06C GTK06C GTK06C APJ648 SD78 HU6DS HU6DSWA HU6DSWC HU6DX EK06 EK06 EK TC EK06 EK06 EK TC C C PKGTA PKOGTC ACP604BC APJ648 HU6RB HU6WA HU6WC HU6WH C C GTK06 GTK06C ACP604BC APJ648 SD78 HU6 HU6A HU6AWA HU6AWC C C GTK06 GTK06 GTK06C GTK06C ACP4CD APJ487 HU6AWK HU6DF HU6DS HU6DSWA 9999TC TC 0 0 H0SN C C H0SNC GTK06 GTK06C PKOGTC ACP4CD HU6DSWC HU6DX HU6RB HU6WA TC TC C C GTK06 GTK06C APJ487 ACP4CD HU6WC HU64 HU64A HU64AWK EK EK EK EK EK EK H0SN H0SN H0SN H0SNC H0SNC H0SNC PKOGTC PKOGTC PKOGTC APJ487 HU64DF HU64DS HU64RB HU6 E 9999R8 EK EK 9999R9 EK EK H0SN H0SN H0SNC H0SNC C PKOGTC PKOGTC PKOGTC Continued on next page

3 8 /09 UL Listed Maximum Short Circuit Current RatingsAC Only NOTE: Consult the wiring diagram of the switch to verify the UL Listed short circuit current rating. Table : Fusible Short Circuit Current Ratings Heavy Duty Safety Switch UL Listed Short Circuit UL Listed Fuse Class Type Current Ratings H, K ka Fusible R, J, L 0 ka On 600 V 0 A switches, 0,000 A max. on corner grounded delta when protected by Class J or R fuses. Table 6: Non-Fusible Safety Switches Heavy Duty Switch Rating Fuse or Circuit Safety Switch (A) Breaker Type Type -Phase 40 Vac 480 Vac 600 Vac Any brand circuit breaker All H, K Up to ka R,T,J.L 0 ka 0 ka 0 ka 0 0 H 6 ka ka ka 0 0 FA 4 ka 4 ka 4 ka Non-Fusible 0 0 FH 8 ka 8 ka 8 ka Switches 0 H, J 6 ka ka ka 0 KA 400 LA ka ka ka 600 MA 0 KH 400 LH ka ka ka 600 MH Applies to NEMA Types, R, 4X stainless, switches. Ampere rating of fuse or circuit breaker not to exceed switch ampere rating. All H and J circuit breakers are acceptable, but will only support the noted Short Circuit Current Rating. Table 7: Terminal Lug Data (NEMA Types, R, 4, 4X,, 7, 9, ) Rating (A) Conductors Per Phase and Wire Range Wire Bending Space Per NEC Table.6 AWG/kcmil Lug Wire Range AWG/kcmil Optional Versa-Crimp Compression Lug Field-Installed 6 (Al) or 4 6 (Cu) (Al) 0 4 (Cu) solid or or 4 (Cu) 4 (Cu) stranded (Al) or 4 (Cu) (Al) or 4 (Cu) 0 /0 (Al) or 4 /0 (Cu) /0 (Al) or 4 /0 (Cu) VCEL04S (Al/Cu) 6 00 (Al/Cu) VCEL006H VCEL07H /0 70 (Al/Cu) 6 /0 70 (Al/Cu) or 400 or or and VCEL006H 7 /0 00 (Al/Cu) /0 00 (Al/Cu) and VCEL00H 600 /0 00 (Al/Cu) /0 00 (Al/Cu) VCEL00H 800 /0 70 (Al/Cu) /0 70 (Al/Cu) H8LKE 8 4 /0 70 (Al/Cu) /0 70 (Al/Cu) HLKE A switches suitable for 60 C or 7 C conductors. 0 A switches suitable for 7 o C conductors. For NEMA Types and R only. HU46AWK 4 6 AWG (Cu). 4 H60XFA 4 6 AWG (Cu). HXKA 4 AWG 00 kcmil (Cu). 6 Maximum wire range is () 600 kcmil or () 00 kcmil Al/Cu on NEMA Type 4X Stainless and NEMA Type. 7 Order two PK6KN mounting kits when installing VCEL006H lugs. Only one kit is required on two-pole switches. 8 See Digest 7 page, 800 and A compression lug kits for additional information. 09 Schneider Electric

4 Table 8: 0 A Heavy Duty Rating HDS HA HAWK HN HNRB HDS HA HAWK HN HNRB H6 H6RB H6DS H6A H6AWK H6A H6AWK H6N H6NRB H46 H46DS H46AWK HU6 HU6RB HU6DS HU6A HU6AWK HU46 HU46DS HU46AWK Vac 40 Vac 480 Vac 600 Vac Vdc 40 Vac 480 Vac 600 Vac Series Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. E Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø / / / / / / / -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ Use both outer switching poles. For corner grounded only, install neutral and use switching poles for ungrounded conductors. Standard hp rating Schneider Electric /09 9

5 9 /09 09 Schneider Electric W W W/H H H W/H D D Typical NEMA Type Typical NEMA Type R Table 9: Dimensions Series Approximate Dimensions H W W/H D in. mm in. mm in. mm in. mm H64 H64N H64NRB H64RB H6, N H6R, NR H66, N H66NR, R H67, N H67NR, R H68, N H68NR, R H46 H46 H46 H H46 H466 HU6 HU6R HU66 HU66R HU67 HU67R HU68 HU68R HU6 H6RB HU6 HU6RB HU6WH HU HU6RB HU64 HU64RB HU6 HU6R HU66 HU66R HU HU67R HU68 HU68R HU46 HU HU46 HU HU46 HU

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D 2 N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D 2 N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Enclosed Safety Switches

Enclosed Safety Switches Enclosed Safety Switches Catalog CT0901 09 Class CONTENTS Description............................................. Page General Duty Safety Switches.............................. Page 4 Heavy Duty Safety

More information

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Selection Guide Contents Descriptions Page General Information Features and Benefits 2-3 Product Illustrations General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Heavy Duty Safety

More information

Safety Alert: Square D Safety Switches

Safety Alert: Square D Safety Switches Safety Alert: Square D Safety Switches Be Sure to Inspect Your Installed Units for Defects Schneider Electric has issued an offer safety alert on the Square D safety switch due to electrical shock hazard

More information

Section 3. Table of Contents. Safety Switches. General Duty. Light Duty. Heavy Duty. Double Throw 3-1

Section 3. Table of Contents. Safety Switches. General Duty. Light Duty. Heavy Duty. Double Throw 3-1 Table of Contents Section Safety es General uty General uty & Not -2 Application ata and imensions - Standards: UL 98 Enclosed and ead Front es. UL Listed under File E2875. NEMA Standards Publication KS1.

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................

More information

Light Duty. General Duty. Heavy Duty. Double Throw Vdc Photovoltaic Heavy Duty Disconnect Switch. Standards:

Light Duty. General Duty. Heavy Duty. Double Throw Vdc Photovoltaic Heavy Duty Disconnect Switch. Standards: Table of Contents Section Safety Switches Light uty Fusible -2 Application ata and imensions - Standards: UL 98 Enclosed and ead Front Switches. UL Listed under File E2875. NEMA Standards Publication KS1.

More information

1.1. Switching Devices. Safety Switches

1.1. Switching Devices. Safety Switches . Catalog Number Eaton General Electric Siemens Square D Fusible, Three-Pole, Four-Wire, 20 Vac, NEMA 3R 30 DH32NRK TH32R HF32NR H32NRB 60 DH322NRK TH322R HF322NR H322NRB 00 DH323NRK TH323R HF323NR H323NRB

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

1.1. Switching Devices

1.1. Switching Devices . Switching Devices Six-Pole Motor Circuit Contents Description Page Product Overview......................... V2-T-2 General Duty............................. V2-T-24 Heavy-Duty..............................

More information

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures 30-600 Amperes: TG and TH 800-1200 Amperes: TC Equipment Ground Kits Ampere Rating AWG/kcmil Copper AWG/kcmil Aluminum Standard Package

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Safety Switch. Type VBII. cross-reference GUIDE

Safety Switch. Type VBII. cross-reference GUIDE Safety Switch Type VBII cross-reference GUIDE General Duty 240 Volt, Type 1 (Indoor) 2-Pole, 2-Wire, Fusible 2-Pole, 3-Wire, Fusible 3-Pole, 3-Wire, Fusible 3-Pole, 4-Wire, Fusible 30 Use 60 Use Use Use

More information

1.3 Enclosed Rotary Disconnects Product Overview... Product Selection... Dimensions...

1.3 Enclosed Rotary Disconnects Product Overview... Product Selection... Dimensions... DH362NRK Safety Switch. Product Overview........................................ Cross-Reference...................................... Selection............................... Options and Accessories................................

More information

Solar Combiner Solutions

Solar Combiner Solutions Solar Combiner Solutions Providing combiners and disconnects that offer superior resistance and durability from harsh weather and abusive solar environments Solar Technology Leading the way in Solar Technology

More information

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1 Sect_0_Speedfax2007 /26/07 5:05 PM Page -1 SPEEDFAX TM 2007-2008 Safety Switches Contents Safety Switch Guide Form Specifications -2 Feature Comparison - Enclosure Types -4 Catalog Numbering System -5

More information

Digest 176. Supplemental and Obsolescence. Global Specialist in Energy Management. Power. Management. Process & Machines. Management.

Digest 176. Supplemental and Obsolescence. Global Specialist in Energy Management. Power. Management. Process & Machines. Management. 2012 Supplemental and Obsolescence Digest 176 Global Specialist in Energy Management Power Management Process & Machines Management IT/Server Room Management Building Management Security Management The

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

Solar Combiner Solutions

Solar Combiner Solutions Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from

More information

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings.

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings. Ratings Ferraz Shawmut Class H, K and R Fuse Blocks accommodate all Class H, K and R 250 and 600V power fuses. A choice of screw, pressure plate, box and special order stud connectors fit a wide range

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description

More information

T CLASS T FUSE BLOCKS

T CLASS T FUSE BLOCKS Ferraz Shawmut Fuse Blocks accommodate fuses up to 600A. Insulators are either of durable, glassfilled polycarbonate (GFPC) or phenolic with verified dielectric strength in excess of 2500V. Ferraz Shawmut

More information

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle Features 30-600A, 600VAC and DC ratings UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 15852 Visible blade quick make and break switching action Panel and Flange mounted assemblies

More information

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

Instructions for Installation, Operation and Maintenance of: WSRD Interlocked Receptacles 30, 60 & 100 Ampere 331114-1 INSTRUCTION SHEET Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere Read instructions carefully and with full understanding for safe

More information

General and Heavy Duty Safety Switches

General and Heavy Duty Safety Switches General and Heavy Duty Safety es Accessories 10/01/13 Selection 4 Class R Fuse Clip Kits All General Duty and Heavy Duty es are field convertible to accept Class R Fuse Clip Kits. The kits prevent the

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

Spring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate

Spring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate Class H, K & R USE LOCKS 250 & 600V CLASS H, K & R USE LOCKS RATINGS: Volts: 250VAC/DC, 600VAC/DC Amps: 30A, 60A, 00A, 0A, 400A, 600A SCCR: 0kA with class H fuses; 50kA with class K fuses; 0kA with class

More information

Laser Service Factory-assembled Panelboards

Laser Service Factory-assembled Panelboards Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page

More information

Switching Devices. 1.2 Enclosed Circuit Breakers. 1.3 Enclosed Rotary Disconnects

Switching Devices. 1.2 Enclosed Circuit Breakers. 1.3 Enclosed Rotary Disconnects Switching Devices DH362NRK Safety Switch. Product Overview......................................... V2-T-2 General Duty............................................. V2-T-24 Heavy-Duty..............................................

More information

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Arktite Heavy Duty Circuit Breaking Plugs and Connectors Arktite Heavy Duty Circuit Breaking Plugs and Connectors 60 A, 600 VAC/250 VDC, 50**-400 hertz Dimensions Page 968 1P Plug Connector Mating APJ Plugs Mating APR Connectors Style 1 Description Cat. # Dia.

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous 3P Description Page No. Application/Selection 1016, 1017 Interlocked Receptacle with Disconnect Switch WSR 30, 60, 100A Aluminum 1018,

More information

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com AR331 30 Amp Pin & Sleeve Recpt 3-W 3-P 250VDC/600vac Cooper Crouse-Hinds Catalog Number

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas 1P Arktite Heavy Duty Circuit Breaking s and s Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically operated

More information

GHN424NW HHN426N HUN361AW

GHN424NW HHN426N HUN361AW GHN424NW HHN426N HUN61AW Passed The Test of Time All Murray safety switches have passed rigid testing requirements to assure reliable performance. In addition to tests designed and conducted during the

More information

LO 4 TK 5 LW 7. Item 1. 5 or 6 9 T 10 J 11 FE 12 CK 13 CL 14 G 15 L or 3 17 CP 18. Item 2 SN 19. Ampere Rating

LO 4 TK 5 LW 7. Item 1. 5 or 6 9 T 10 J 11 FE 12 CK 13 CL 14 G 15 L or 3 17 CP 18. Item 2 SN 19. Ampere Rating ing Devices. Modifications Flex Center Introduction The Safety Flex Center is a special facility at the site of our Cleveland, Tennessee, plant that is dedicated to providing customized safety that meet

More information

NMC Combination Line Starters and Enclosures

NMC Combination Line Starters and Enclosures NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch . Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A

More information

Type VBII Visible Blade Disconnect Switches

Type VBII Visible Blade Disconnect Switches Type VBII Visible Blade Disconnect es Product Guide Siemens Type VBII visible blade disconnect switches meet either UL98 or UL1741 requirements and can be used in either service entrance or branch circuit

More information

For Options, Modifications and Accessories, see pages Discount Schedule A6

For Options, Modifications and Accessories, see pages Discount Schedule A6 Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F

More information

Thermal-Magnetic For Mining Applications Class 600

Thermal-Magnetic For Mining Applications Class 600 Square D www.squared.com FOR CURRENT INFORMATION Molded Case Circuit Breakers for Mining s These circuit breakers with the properly selected trip range provide protection for trailing cables in compliance

More information

Section 4. Safety Switches.

Section 4. Safety Switches. Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG...4-5 eavy Duty, Type T...4-7 eavy Duty Stainless Steel, Type T...4-11 Mill Duty, Type T...4-13 Double Throw Switches, Type TC, TDT...4-15

More information

Switches. Safety and Disconnect Switches. Heavy Duty Safety Switch Standards and Ratings

Switches. Safety and Disconnect Switches. Heavy Duty Safety Switch Standards and Ratings Safety and Disconnect es Contents Pages Heavy Duty Safety es Safety Features........................18/2 Selection, 240V Fusible........................18/3 Selection, 600V Fusible........................18/4

More information

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed Arktite Circuit Breaking CPS Application: CPS receptacles, angle and straight types, and CPP plugs are used: with portable electrically operated devices such as motor-generator sets, compressors, conveyors,

More information

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles 1P Arktite Heavy Duty Circuit Breaking s and Receptacles Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically

More information

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview

More information

Safety Switches Section 4

Safety Switches Section 4 Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG... 4-5 eavy Duty, Type T...4-7 eavy Duty Stainless Steel, Type T... 4-11 Mill Duty, Type T...4-13 Double Throw Switches, Type TC, TDT...4-15

More information

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940 Well-Guard Control Pumping Plant Panels Catalog 8940CT9701R11/15 2016 Class 8940 IRRIGATION OIL PRODUCTION CONTENTS Selection.............................................. Page 3 Factory Modifications.....................................

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................

More information

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC) 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC) Appleton/Oz Gedney Catalog Number ACP1034CD Manufacturer Appleton/Oz Gedney

More information

Fuseblocks. Voltage Ratings: Ampere Ratings: Leakage Current: Catalog/system number Torque Range System Number

Fuseblocks. Voltage Ratings: Ampere Ratings: Leakage Current: Catalog/system number Torque Range System Number class T FuseBlocks NEW! Smaller Design Description The new Littelfuse Class T fuse blocks offer many advantages over previous generations that are noted in the features and benets section. Of particular

More information

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 APJ10487 100 Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac Cooper Crouse-Hinds Catalog Number Manufacturer Description

More information

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 ARL2042 Receptacle Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Descriptions

More information

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC) 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC) Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A Conformity to standards (1) Changeover switches svr-ul_14_b_1_cat > EC 6947-3 > UL98, Guide WHTY, file 1138 > UL18, Guide WPYV, file 31792 > CSA 22.2#4, Class 4651-2 (1) Product reference on request. svr_136_a_2_cat

More information

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

PANELBOARDS SECTION 1

PANELBOARDS SECTION 1 SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector

More information

Just the right switch for your application

Just the right switch for your application Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles ENR Value Series Dead Front Interlocked Circuit Breaking s Cl. I, Div. & 2, roups B, C, D Cl. II, Div. & 2, roups F, Cl. III, 7BCD, 9F, 2 Dust-Ignitionproof Raintight et Locations ENP Plugs Applications:

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Quik-Spec. Section Contents

Quik-Spec. Section Contents Section Contents Page Quik-Spec Coordination Panel Boards......... 238-239 Quik-Spec Power Module Switches and Panels.. 240-241 Quik-Spec DC Safety Switches.................. 242 Quik-Spec Solar Combiner

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

Section 4. Safety Switches.

Section 4. Safety Switches. Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG... 4-5 eavy Duty, Type T...4-7 eavy Duty Stainless Steel, Type T... 4-11 Mill Duty, Type T...4-13 Double Throw Switches, Type TC, TDT...4-15

More information

LFJ602003C 200A 600V Fus Block

LFJ602003C 200A 600V Fus Block 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LFJ602003C 200A 600V Fus Block Littelfuse Catalog Number Manufacturer Description Weight per unit Product Category Descriptions

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors,

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles P Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable

More information

Contents. Product Overview

Contents. Product Overview .1 Switching Devices Rotary Disconnect F-Frame Fusible Product Overview Product Selection Guide Safety Switch Contents Description Page Product Overview Standards and Certifications.......................

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch Double-Throw, continued Ampere Rating Catalog Number Selection Safety Switch Catalog Number Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA X 30 N/A N/A N/A N/A

More information

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. NEC EBR Receptacle:

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. EBR Receptacle Class

More information

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous Description Page No. Application/Selection see pages 1260 1261 Arktite Delayed Action Circuit Breaking Technical Data see pages 1262 126 20

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically operated devices

More information

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install Midwest Electric Products Safety Switches Rugged, reliable and easy to install Midwest Safety Switches Features Midwest Electric Products offers a wide variety of general duty and heavy duty safety switches,

More information

Residential Transition Box. Model RU-1. Specifications. Electrical

Residential Transition Box. Model RU-1. Specifications. Electrical Residential Transition Box Model RU-1 Model RU-1 transition box provides a quick, simple, and easy transition between a microinverter trunk cable and stranded wire. Using only a single flathead screwdriver,

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

Selection and application guide

Selection and application guide Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 00A 30A 00A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

600V, Non-Fusible, (3-Pole, 3 Phase)

600V, Non-Fusible, (3-Pole, 3 Phase) 0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

fastfax Rock Solid TM Load Centers General Information

fastfax Rock Solid TM Load Centers General Information General Information FEATURES UL Listed. Straight-in wired, bolt-on main breaker for 100-225 amps. Neutral and ground bars have multiple 1/0 conductor terminals. Factory installed ground bars on all devices.

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Arktite Plugs, Receptacles, and Connectors

Arktite Plugs, Receptacles, and Connectors Arktite Plugs, Receptacles, and Connectors Arktite Plugs, Receptacles, and Connectors THE COOPER CROUSE-HINDS STANDARD Put a century of standard-setting experience to work for you. For more than a century,

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically