Enclosed Safety Switches

Size: px
Start display at page:

Download "Enclosed Safety Switches"

Transcription

1 Enclosed Safety Switches Catalog CT Class CONTENTS Description Page General Duty Safety Switches Page 4 Heavy Duty Safety Switches Page 11 Double Throw Safety Switches Page 4

2 Enclosed Safety Switches CONTENTS CATALOG NUMBER DESCRIPTION... GENERAL DUTY SAFETY SWITCHES... 4 Product Description... Configuration... Construction... Enclosures... 6 Accessories... 6 Class R Fuse Kits... 6 Fuse Puller Kits... 6 Equipment Grounding Kits... 6 Electrical Interlock Kits... 7 Field-Installed Lug Kit... 7 Class J Fuse Kit... 7 HEAVY DUTY SAFETY SWITCHES Product Description... 1 Configuration... 1 Construction... 1 Enclosures... 1 Receptacle Switches Appleton Powertite Receptacle Crouse-Hinds Arktite Receptacle Hubbellock Receptacle Motor Disconnect Switches... MD... Compliances... Application Standards General dc and Photovoltaic Systems Special Applications Accessories... Hubs... Class R Fuse Kits... Solid Neutral Assemblies... Equipment Grounding Kits... Electrical Interlock Kits... 1 Fuse Puller Kits... 1 Optional Compressor Lugs... 1 Key Interlock System... 1 Lock-Off Guard... Internal Barrier Kits... DOUBLE THROW SAFETY SWITCHES... 4 Product Description Construction Enclosures Accessories... 4 NOTE: For information on Replacement Parts with specific part numbers, go to click on Product FAQ s, enter the device catalog number, click SEARCH, then look for the information required. 09 Schneider Electric 11/09

3 Catalog Number Description Enclosed Safety Switches Number Segment Character Description D 1 N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double throw 1 1 pole poles Blades Switchable Poles poles 4 4 poles 6 6 poles 1 1 Vac (plug fuse) Voltage Rating 1 Vac 6 0 Vac 1 A A A 4 0 A Ampere Rating 0 A 6 0 A A 8 A Factory-installed neutral (neutrals are field-installed on most general duty, heavy duty, Neutral N and double throw safety switches). No suffix NEMA Type 1 A NEMA Type 1K AWK NEMA Type 1 (without K.O.) DF NEMA Type 4X Fiberglass reinforced polyester Enclosure DS NEMA Types 4, 4X, and (Type 4 stainless steel) DX NEMA Type 4X Krydon 1 Factory Modifications For dc ratings, see the latest catalog listing. R NEMA Type R RB NEMA Type R (bolt-on hub provision) SS NEMA Types 4, 4X, and (Type 16 stainless steel) CLR Class R fuse kit EI or EI Electrical interlock kit GL Equipment ground lugs GLC Equipment ground lug, copper only KI, KI or KIKI 1 or Key interlocks LK Compression lugs (800 and A only) NP Phenolic legend plate PB Push buttons, pilot lights, selector switches. Customer must provide catalog number of control device to be installed SLC Copper lugs ( 0 A) SP Special paint colors SPLO Lock-on provision VW Viewing window WA Appleton interlocked receptacle WC Crouse-Hinds Arktite interlocked receptacle WH Hubbellock interlocked receptacle 09 Schneider Electric 11/09

4 Enclosed Safety Switches GENERAL DUTY SAFETY SWITCHES CONTENTS Product Description... Configuration... Construction... Enclosures...6 Accessories...6 Class R Fuse Kits...6 Fuse Puller Kits...6 Equipment Grounding Kits...6 Electrical Interlock Kits...7 Optional Field-Installed Lug Kit...7 Class J Fuse Kit...7 Application and Standards /09 09 Schneider Electric

5 General Duty Safety Switches Enclosed Safety Switches General Duty Safety Switches Product Description General duty safety switches are designed for residential and commercial applications where durability and economy are a prime consideration. Typical loads include lighting, air conditioning, and appliances. They are suitable for use as service equipment when equipped with a factoryinstalled neutral assembly or field-installed service grounding kit, as applicable. General duty safety switches are UL Listed, File E8, and meet or exceed the NEMA Standard KS1. The switches are also available with CSA rating. Configuration Two fusible switched poles with insulated, grounded neutral Three fusible, switched poles with insulated, grounded neutral Two or three, not fusible, switched poles without insulated, grounded neutral Construction Indoor NEMA Type 1 or Outdoor NEMA Type R enclosures Visible blades for positive indication that the switch is OFF Quick-make, quick-break operating mechanism Lugs suitable for aluminum or copper conductors. See page 8 for additional lug data Spring reinforced, plated copper fuse clips Visible Blade Construction Operating Mechanism with Line Base Series F Series F handle/lock-plate is a field-replaceable modular design Series F operating mechanism is an enclosed, field-replaceable, modular design Series F NEMA Type R covers have side opening construction Top endwalls in 0 A NEMA Type R switches have bolt-on hub provisions Multiple padlock provisions in OFF position Tangential combination knockouts alleviate the need for offset bends Wall 09 Schneider Electric Tangential Knockouts 11/09

6 Enclosed Safety Switches General Duty Safety Switches Enclosures Enclosures are finished in gray, baked enamel that is electrodeposited on cleaned, phosphatized steel. NEMA Type 1 general purpose, indoor NEMA Type R general purpose, outdoor Accessories Rainproof Hubs Bolt-on hubs for rainproof applications. Switches with RB suffix accept /4 through -1/ inch bolt-on hubs. Switches with R suffix have blank endwalls. Class R Fuse Kits For systems up to,000 rms symmetrical amperes See page 9 for selection RB Hub Class R Fuse Kits Series F Fuse Puller Kits Kit consists of three fuse pullers as required for a -pole fusible A or A general duty switch. Kits can be installed into or A Series F switches. Table 1: Fuse Puller Kits Equipment Grounding Kits Aluminum or copper conductors Field-installed Table : Equipment Grounding Kits Fuse Puller Kit Series F Switch Ampere Rating Series Number Fuse Puller Kit Catalog Number F FPK0 F FPK06 and A A Switch Ampere Rating Catalog Number Equipment Grounding Kit Catalog Number, Series E PKGTA1 () 1 Cu or () Al or (1) 4 Al/Cu Max. Series F GTK0 () 1 Cu or () Al or (1) 4 Al/Cu Max. () 1/0 Al/Cu Max. 0 A 0 PK0GTA () /0 Al/Cu Max. Grounding Kits 0, 0 PK0GTA (Two required) () /0 Al/Cu Max. Per Lug 800 PK0GTA (6) /0 Al/Cu Max. 6 11/09 09 Schneider Electric

7 Enclosed Safety Switches General Duty Safety Switches Electrical Interlock Kits Electrical interlocks for Series F 0 A general duty safety switches and Series F A fusible general duty safety switches are available in kit form for field installation. Each kit contains instructions for proper field mounting. A pivot arm operates from switch mechanism, breaking the control circuit before the main switch blades break. Switches with electrical interlocks installed are UL Listed, Table : Electrical Interlock Kits Switch Ampere Rating Electrical Interlock Kit Catalog Number 1 Fusible Series F Series F 0 EIK01 or EIK0 EIK-1 or EIK- 1 Electrical interlock kit catalog numbers with -1 suffix indicate one normally open and one normally closed contact; - indicates two normally open and two normally closed contacts. Kits are UL Listed. Table 4: Electrical Interlock Contact Ratings 1 AC or Hz DC Interlock Type Volts Make Break Cont. Volts Make / Break Cont A.00 A.00 A 1 0. A.00 A 1 N. O. / 1 N. C. Contact (-1 Suffix ) N. O. / N. C. Contacts (- Suffix ).00 A.00 A.00 A 0. A.00 A A 6.00 A.00 A A.00 A.00 A A.00 A 1.00 A.00 A.00 A A.00 A.00 A 1. A.00 A 0. A.00 A A 0. A.00 A A 0. A.00 A 0 0. A.00 A 1 Single-pole single-throw interlock kits are rated 1/ hp at 1 and Vac. -1 Suffix uses a 9007A01 limit switch. - Suffix uses a 9007C0 limit switch. Optional Field-Installed Lug Kit Kit consists of three line, three load, and two neutral lugs as required for a -pole 0 A or 0 A general duty switch. Kit can be installed on 0 A or 0 A Series E switches only. Table : Field-Installed Lug Kit Switch Ampere Rating Lug Kit Catalog Number Wire Range/NEC Lug Wire Range 0 or 0 Series E 1 GDLK 1-1/0-0 kcmil -1/0-0 kcmil 4-1/0- kcmil -1/0-0 kcmil 4-1/0- kcmil 1 Not suitable for use on 0 A NEMA Type R. Field-Installed Lug Kit for 0 and 0 A Devices Class J Fuse Kit The Class J Fuse Kit consists of three Class J fuse adapters as required for a three-pole fusible 0 A general duty switch. Kit can be installed in 0 A Series E switches only (NEMA Type 1). Table 6: Class J Fuse Kit Switch Ampere Rating Class J Kit Cat. No. 0 A Series E GDJK0 09 Schneider Electric 11/09 7

8 Enclosed Safety Switches General Duty Safety Switches L11N NOTE: Switch is load make/break. Application General duty safety switches are designed for the following applications: Residential and light commercial applications Infrequent or moderate operations Vac maximum Up to,000 rms symmetrical amperes, using appropriately rated Class R fuses and Class R Fuse Kits, or Class T or J fuses 800 A Horsepower rated Load-make, load-break rated for the switch current rating. The light duty enclosed switch is ideal for home applications in disconnecting power to workshops, hobby rooms, furnaces and garages. Light dutyvisible blades,000 A short circuit current rating A fusible and non-fusible, Vac Replacement parts not available Available with plug or cartridge fuse holders Standards General duty safety switches are manufactured in accordance with these standards: UL 98, Standard for Enclosed and Dead Front Switches. UL Listed under File E8 NEMA Standards Publication KS1, Enclosed Switches Federal Specifications WS-86c for Type NDS (NEMA Type 1) and Type LD (NEMA Type R) UL/CSA Listed Short Circuit Current Rating (RMS Symmetrical) Switch Type Fuse Class Short Circuit Rating Fusible Non-Fusible 1 Table 7: Terminal Lug Data 1 Plug H J R T ka ka ka ka ka H ka J ka R ka T ka 1 The UL Listed short-circuit current rating for Square D general duty non-fusible switches is based on the switch being used in conjunction with fuses. Evaluation of non-fusible switches in conjunction with molded case circuit breakers has not been performed. If a UL Listed short circuit current rating is required, this non-fusible switch must be replaced with a Square D general duty fusible safety switch, equipped with the appropriate class and size fusing. The UL Listed short circuit current rating of the fusible switch is typically as follows: when used with Classes H and K fuses ka, Classes J and R fuses ka. Consult the wiring diagram of the switch to verify the UL Listed short circuit current rating. ka for A non-fusible switch. Ampere Rating Conductors Per Phase Wire Range Wire Bending Space Per NEC Table 1.6 AWG/kcmil Lug Wire Range AWG/kcmil 8 11/ (Al) or 14 6 (Cu) 1 6 (Al) or 14 6 (Cu) 1 (Al) or 14 (Cu) (Al) or 14 (Cu) (Al) or 14 1 (Cu) 1 1/0 (Al) or 14 1/0 (Cu) (Al/Cu) 6 0 (Al/Cu) 0 NEMA Type1 0 NEMA Type 1 or 1/0 0 (Al/Cu) or 1/0 0 (Al/Cu) 1/0 (Al/Cu) (1) 1 7 (Al/Cu) or () 1/0 0 (Al/Cu) (1) 1/0 0 (Al/Cu) or () 1/0 (Al/Cu) (Al/Cu) 4 0 (Al/Cu) 800 /0 0 (Al/Cu) /0 0 (Al/Cu) A switches suitable for C or C conductors A switches suitable for C conductors. 09 Schneider Electric

9 Enclosed Safety Switches General Duty Safety Switches Catalog Number Series Class R Fuse Kits Available for Field-Installation 1 Horsepower Ratings 1 Vac Vac Vac Max. Max. L111N L11N L1N D11N D11NRB D1N D1NRB DN DNRB DN DNRB D4N 4 D4NRB 4 DN Catalog Number 1Ø 1Ø 1Ø Ø 1Ø Ø E 1/ E E 1 Rejection kits are available for Series D, E1, E, and F1 switches. When installed, this kit rejects all but Class R fuses. When installed with this kit and Class R fuses, the switch is UL Listed for use on systems with up to,000 RMS symmetrical amperes available fault current. For corner grounded delta systems only, use switching poles for ungrounded conductors. Suitable for use as service equipment; requires field installation of a service grounding kit (see Digest 1, page -). Solid neutral assembly for Series F is SNA for the DU4 or DU4RB. 4 For 0% neutral, order (1) additional neutral kit SNA and (1) neutral jumper kit SNNI. Suitable for use as service equipment; requires field installation of solid neutral assembly D0SN. 6 Includes factory-installed neutral. 7 Includes factory-installed grounding kit. 8 Not service entrance rated. 9 Enclosed molded case switch Schneider Electric 11/09 1-1/ 1-1/ 1/ 1-1/ E DRK 1-1/ 1-1/ F1 RFK0L 1-1/ F RFK F1 HRK E DRK DNR E1 D6N E DRK0 D6NR E1 DRK0 D1N D1NRB E DRK 1-1/ DN DNRB F1 RFK0L 1-1/ DN F RFK DNRB D4N 4 F1 HRK D4NRB 4 DN DRK 1 E DNT DRKNR DRK 1 E1 DRKNTR D6N DRK0 1 E D6NT D6NR DRK0 1 E1 D6NTR DU1RB E DURB E1 DU 4 DURB 4 F DU4 4 DU4RB 4 F1 DU 4 1 E DU6 4 1 QO0TR QONATS 7 9 QO00NRB QO00NS T7N T7NR G E E1 E1 E1

10 Enclosed Safety Switches General Duty Safety Switches H 11/09 W W / H W W / H Typical NEMA Type 1 D Typical NEMA Type R D Table 8: 1 Catalog Number L111N 1 Switch Dimensions Series H W W/H D in. mm in. mm in. mm in. mm E L11N 1 E L1N 1 E D11N 1 E D11NRB 1 E D1N 1 E D1NRB 1 E DN F DNRB F DN F DNRB F D4N F D4NRB F DN E DNR E D6N 1 E D6NR 1 E D1N 1 E D1NRB 1 E DN F DNRB F DN F DNRB F D4N F D4NRB F DN 1 E DNT 1 E DNR E DNTR E D6N 1 E D6NT 1 E D6NR E D6NTR E DU1RB 1 E DURB 1 E DU1 1 E DU1RB 1 E DU 1 E DURB 1 E DU F DURB F DU4 F DU4RB F DU 1 E DU6 1 E QO0TR 1 G QONATS E QO00NRB E QO00NS 1 E T7N 1 E T7NR 1 E Does not have a cover draw as indicated in above drawing. 09 Schneider Electric

11 HEAVY DUTY SAFETY SWITCHES CONTENTS Product Description...1 Configuration...1 Construction...1 Enclosures...1 Receptacle Switches...14 Appleton Powertite Receptacle...14 Crouse-Hinds Arktite Receptacle...14 Hubbellock Receptacle...14 Motor Disconnect Switches... MD... Applications...16 Standards...16 General dc and Photovoltaic Systems...17 Special Applications...19 Accessories... Hubs... Class R Fuse Kits... Solid Neutral Assemblies... Equipment Grounding Kits... Electrical Interlock Kits...1 Fuse Puller Kits...1 Optional Compression Lugs...1 Key Interlock System...1 Lock-Off Guard... Internal Barrier Kits... General Information Schneider Electric 11/09 11

12 Product Description The Square D brand Heavy Duty Safety Switch is designed to be tough, reliable and provide exceptional performance in the most grueling conditions; from commercial and institutional to industrial and manufacturing facilities. Square D F Series safety switches provide significantly higher levels of mechanical endurance than NEMA KS-1 requires. The design life of a Square D F-Series switch is a minimum of three times the NEMA requirement. An abundance of copper is used in the heaviest current carrying power paths of all Square D Heavy Duty Safety Switches. The more copper for current carrying paths, the lower the temperature rise. Managing temperatures inside the switch is the key to providing greater service life. All heavy duty safety switches feature a quick-make, quick-break operating mechanism, a dual cover interlock and a color-coded indicator handle. Series F Operating Mechanism Series F Visible Blades Configuration Two or three fusible switched poles with or without insulated, solid grounded neutral Four or six fusible switched poles without insulated, solid grounded neutral Two, three, four or six non-fusible, switched poles without insulated, solid grounded neutral Three fusible switched poles without insulated solid grounded neutral interlocked to Appleton, Crouse-Hinds, or Hubbellock receptacle Three non-fusible switched poles without insulated solid grounded neutral interlocked to Appleton, Crouse-Hinds, or Hubbellock receptacle Construction Visible blades for positive blade position indication Optional viewing window allows visual verification of blade position without opening door; not available on NEMA Type 4X fiberglass reinforced polyester or Krydon enclosures or NEMA Type 7 or 9 enclosures Red and black handle indication for switch position Series F handle, mechanism, and lock plate are field replaceable Series F Type R devices have side-opening covers Highly visible embossed ON-OFF marking Quick-make, quick-break, spring-driven operating mechanism Front removable mechanical lugs. Refer to page 8 for further lug data Standard lugs accommodate aluminum or copper cable termination Optional lugs accommodate copper only cable termination Mechanical Lugs 1 11/09 NEMA Type 1 NEMA Type R NEMA Types 4, 4X, and Stainless Steel NEMA Type 1 09 Schneider Electric

13 Dual cover interlock keeps the cover closed when switch is ON. When the cover is open, it interlocks the switch OFF, unless the interlock is bypassed. Factory-installed fuse pullers on A NEMA Types 4, 4X, and stainless steel, NEMA Type 4X fiberglass reinforced polyester, Krydon and NEMA Types 1 or 1K switches. Available for field installation on A F Series switches, NEMA Types 1 and R switches. Class J fuse provisions on A 0 A, 0 V switches and 0 A, V switches. 0 A devices require a mounting kit (catalog number H0J). 0 A switches are shipped with standard Class H fuse spacing. These switches will accept Class R fuses also. A field-installable rejection kit is available, which, when installed, rejects all but Class R fuses. See pages through 6 for Class R fuse kits. Multiple padlock provision in OFF position (three padlocks). Lock-on provisions for factory or field modification. Tangential combination knockouts lessen the need for conduit offset bends. Fuse Pullers Lock-off Provision with Optional Lock-off Guard Kit Installed Enclosures Class J Fuse Provisions Alternate mounting holes make for easy conversion to Class J fuses. Tangential Knockouts Wall NEMA Type 1 general purpose, indoor NEMA Type R rainproof, outdoor NEMA Types 4, 4X, indoor or outdoor, watertight, dust-tight, and corrosion-resistant (Types 4 and 16 stainless steel) NEMA Type 4X indoor or outdoor, watertight and dust-tight, and corrosion-resistant (fiberglass reinforced polyester) NEMA Types 7 and 9 hazardous locations: Class I, Groups C and D Class II, Groups E, F and G Class III NEMA Types 1 and1k indoor, dust-tight, and drip-proof NEMA Type 1 has no knockouts (suitable for outdoor use) NEMA Type 1K provided with knockouts 09 Schneider Electric 11/09 1

14 Receptacle Switches Interlocked receptacle switches are furnished with a factory-installed threephase four-wire Appleton Powertite, Crouse-Hinds Style Arktite, or Hubbellock receptacle. The fourth wire is connected to the switch equipment grounding terminal and is not a solid neutral termination. Interlocking linkage between the receptacle and switch mechanism prevents insertion or removal of the plug while the switch is in the ON position, or insertion of any plug other than specified. The interlocking mechanism also prevents the switch from being turned ON if a plug has not been fully inserted into the receptacle. Appleton Powertite Receptacle H6AWA Interlocked Receptacle Switch with Appleton Powertite Receptacle Devices are UL Listed and CSA Certified, suitable for use as service equipment Receptacles are epoxy powder coated over copper-free cast aluminum A, H6AWA and HU6AWA are stock items. All other items are non-stock and require an 8-week lead time Short circuit rating: ka when used with or protected by Class H or K fuses; 0 ka when used in conjunction with Class R, T, or J fuses Crouse-Hinds Arktite Receptacle Devices are UL Listed and suitable for use as service equipment A, H6AWC and HU6AWC are stock items. All other items are non-stock and require a 1-week lead time Short circuit rating:,000 A when used with or protected by Class H or K fuses; 0,000 A when used in conjunction with Class R, T or J fuses Hubbellock Receptacle H6AWC Interlocked Receptacle Switch with Crouse-Hinds Arktite Receptacle UL Listed and suitable for use as service equipment Short circuit rating: ka H6AWH Interlocked Receptacle Switch with Hubbellock Receptacle 14 11/09 09 Schneider Electric

15 Motor Disconnect Switches Heavy Duty Safety Switches Square D, a brand of Schneider Electric, brings to the market a comprehensive offering of Motor Disconnect switches listed UL8 "Suitable as Motor Disconnect". The MD IEC9 mechanical interlock receptacle switches address fixed and flexible process requirements. MD The MD motor disconnect is a pin and sleeve interlocked switch receptacle listed UL 8 "Suitable As Motor Disconnect" in one compact Type 4X enclosure. It is offered in,,, and A units compatible with IEC9- plug configurations. The MD UL 8 switch with receptacle interlock allows motor driven equipment and motors to be moved into and out of a given space when necessary. Plus, a key safety feature is that the interlock switch design requires an operator to turn off the load before removing the machine plug from the receptacle. Compliances UL Listed 98 File Number E8 and E17818 UL Listed 8 Industrial Control Equipment UL Listed 168 and 1686 Plugs and Receptacles, Pin and Sleeve Type CSA Certified. No. 4-M91 File Number E4 IEC 9-1; IEC 9- Enclosure: plastic Types 4X and 1 UL 94 V Flame Rating UV Stabilized Material IP66 09 Schneider Electric 11/09

16 Applications Heavy duty safety switches are designed for the following applications: Commercial and industrial installations Up to 0 Vac or 0 V dc maximum Up to 0,000 rms symmetrical amperes short circuit current A Horsepower ratings Load-make, load-break rated for the switch current rating Two or three fusible switched poles with or without insulated, grounded neutral Four or six fusible switched poles, neutral not available Two or three non-fusible, switched poles with or without insulated, grounded neutral Four non-fusible switched poles, neutral not available Six non-fusible switched poles, neutral not available Tested and approved for seismic applications Standards Heavy duty safety switches are manufactured in accordance with these standards: UL98, Standard for Enclosed and Dead Front Switches. UL Listed under File E8, or E488 NEMA Standards Publication KS1, Enclosed Switches Federal Specifications WS-86c for Type HD 16 11/09 09 Schneider Electric

17 NOTE: Heavy duty safety switches may be used on photovoltaic systems with a grounded feed. Refer to Figures 1B, 1D, 1F and (negative grounding shown; positive grounded systems are similarly allowed). For ungrounded systems, see National Electrical Code (NEC ) 690. (NEC 08, NFPA 70). Figure 1: Heavy Duty Safety Switches General dc and Photovoltaic Systems As a market leader and innovator in photovoltaic (PV) applications, we are proud to announce a catalog section dedicated to dc and PV safety switch applications. This section focuses on the Square D brand UL approved Heavy Duty Safety Switch dc and PV wiring schemes. Additionally a UL witnessed and Square D self-certified PV wiring option is presented. This additional unlisted option provides a robust, cost effective option for PV systems. All heavy duty safety switches with dc ratings (-, - and 4-pole fusible and nonfusible) are Underwriters Laboratories (UL) Listed and CSA Certified for use on dc applications when wired as shown in Figure 1 (A, B, C, D, E, and F). UL Listed, CSA Certified (Files E8 and E48). Additionally: Heavy duty safety switches are rated for 0 Vdc maximum open circuit voltage. Non-fusible safety switches may carry percent of the nameplate current rating. Fusible safety switches may carry 80 percent of nameplate current rating (continuous use). Heavy duty switches are dc horsepower rated as indicated on the safety switch wiring diagram. Heavy duty switches have a,000 ampere dc short-circuit rating at 0 Vdc unless otherwise stated on the switch wiring diagram. Consult factory for short circuit current ratings at Vdc. Refer to current Square D Digest for lug wire range of heavy duty switches. General dc and Photovoltaic Systems, Fusible and Non-Fusible Wiring Diagram (Non-Fusible Shown) LINE 0 Vdc LINE 0 Vdc LINE 0 Vdc LOAD LOAD LOAD LINE (Four-Pole) A 0 Vdc LINE LOAD (Three-Pole) C 0 Vdc (Two-Pole) E LINE 0 Vdc LOAD LOAD LOAD LOAD 09 Schneider Electric (Four-Pole) B (Three-Pole) D (Two-Pole) F 11/09 17

18 Alternate Photovoltaic System Wiring, Evaluated and Self-Certified by Schneider Electric (Not UL Listed) Figure : Grounded Feed per NEC Article 690 Photovoltaic Array or String Max Open Circuit Voltage 0 Vdc ( ) ( ) ( ) ( ) ( ) ( ) A, 0 V Fusible or Non- Fusible Disconnect (Fusible Shown) ( ) ( ) ( ) ( ) Connect negative photovoltaic line (-) to case inside inverter for negative grounded system. Positive grounded systems are similarly allowed. For ungrounded systems, see NEC 690. (NEC08, NFPA70). Current Ratings 1 Switch Nameplate 0 V Switch dc Rating per Pole 1 (To Inverter) Photovoltaic Maximum Circuit Current Photovoltaic Short-Circuit Current (l sc ) A A 16 A dc per pole 1.8 A (/1.6) A A 48 A dc per pole 8 A (/1.6) A A 80 A dc per pole 64 A (/1.6) The switch per pole rating must be at least the photovoltaic maximum circuit current multiplied by 1%. From NEC 08 and NFPA 70, Article 690.8: the photovoltaic maximum circuit current is I sc multiplied by 1%. If a non-fusible disconnect is used, the inverter must not be capable of backfeeding currents into a short circuit or fault in the photovoltaic array or string. One inverter may be connected to each pole of the switch. Refer to current Square D Digest for lug wire range of heavy duty switches /09 09 Schneider Electric

19 Special Applications Rainproof Bolt-On Hubs Electrical Interlock Kits Available factory- or field-installed Pivot arm operates from switch mechanism, breaking the control circuit before the main switch blades break Switches with electrical interlocks installed are UL Listed Watertight Hubs Class R Fuse Kits Internal Barrier Kits Provide an additional barrier that helps prevent accidental contact with live parts Field-installed transparent barriers do not restrict visual inspection of the switch Barriers provide IEC9 IPX finger safe protection when door of enclosed disconnect switch is open Convenient door allows use of test probes without accessing fuses Allows for replacement of fuses without removing barrier NOTE: Barrier can also be used with a skirt kit to enclose a panel mounted Type 94 disconnect. Key Interlock Systems Factory-installed only Interlocks are used to prevent the authorized operator from making an unauthorized operation Not available on hazardous location devices (NEMA Types 7 or 9) or fiberglass reinforced polyester (NEMA Type 4X) UL Listed Lock-On Provisions Provision for one /8 in. hasp padlock is available factory-installed on NEMA Types 1, R, 4, 4X and stainless steel and 1 switches This modification will allow the switch to be locked in the ON position UL Listed Special Paint Available painted with special safety colors: safety red, safety orange, safety yellow, safety green, safety blue, safety purple, black or white All colors comply with OSHA Standard and ANSI Specification Z.1 for marking physical hazards Phenolic Legend Plate Available engraved and mounted on all heavy duty safety switches, except NEMA Types 7 and 9 Legend engraved in 1/4 in. high white letters on black background Customer must provide legend UL Listed 09 Schneider Electric 11/09 19

20 Accessories Square D brand heavy duty safety switches manufactured by Schneider Electric are UL Listed for use with the following accessories: Hubs Bolt-on hubs for rainproof applications. Switches with RB suffix accept /4 in. through -1/ in. bolt-on hubs. Switches with R suffix have blank top endwalls. Table 9: Rainproof Bolt-On HubsFor Use on NEMA Type R Enclosures Conduit Size / /4 1-1/ -1/ -1/ 4 Closing Cap Bolt-On Hubs Hub Cat. Number B0 B B1 B1 B0 B B0 B B0 BCAP NEMA Type R rainproof enclosures with catalog number ending in RB have a bolt-on closing cap factory-installed. Order bolt-on hubs separately from table above. Hubs through size -1/ in. can be directly installed on RB devices. Devices requiring in. or larger hubs must have holes cut in the field. Gaskets are provided on in. and larger hubs. All hubs are UL Listed for indoor and rainproof applications and suitable for use with conduit having ANSI standard taper pipe thread. Watertight hubs are zinc or chrome plated for field-installation on NEMA Types R, 4, 4X,, and 1 stainless steel switches and Type 1 enclosures. Table : Conduit Trade Size Watertight Hubs 1/ / /4 1-1/ -1/ -1/ 4 Watertight Hubs Standard Zinc Hub Cat. Number H0 H0 H H1 H1 H0 H H0 H H0 Chrome Plated Hub H0CP H0CP HCP H1CP H1CP H0CP Cat. Number Class R Fuse Kits For systems up to 0,000 rms symmetrical amperes provide rejection for all other fuse types. See pages through 7 for catalog numbers. Class R Fuse Kits Solid Neutral Assemblies Factory or field-installed insulated, grounded solid neutral assemblies. See pages through 6 for catalog numbers. Equipment Grounding Kits Equipment grounding kits available for factory- or field-installation. See pages through 6 for catalog numbers. Field-installed Insulated, Grounded Neutral Field-installed Equipment Grounding Kit 11/09 09 Schneider Electric

21 Electrical Interlock Kits Electrical interlocks for heavy duty safety switches through A are available factory installed or in kit form for field installation. A pivot arm operates from the switch mechanism, breaking the control circuit before the main switch blades break. Switches with electrical interlock accessories installed are UL Listed. See pages through 6 for catalog numbers. Table 11: Electrical Interlock Contact Ratings 1 Interlock Type 1 N.O./ 1 N.C Contact (-1 Suffix) N.O./ N.C Contact (- Suffix) ac or Hz Volts Make Break Cont. Volts A.0 A.0 A 8.0 A.0 A.0 A 7. A 6.0 A.0 A.0 A 6.0 A.0 A.0 A 1. A 0. A 0. A.0 A.0 A.0 A.0 A.0 A.0 A.0 A.0 A Single-pole single-throw interlock kits are rated 1/ hp at 1 and Vac. dc Make and Break 0. A 0. A 0.0 A 1.00 A 0. A 0. A Cont..0 A.0 A.0 A.0 A.0 A.0 A -1 Suffix uses a 9007A01 limit switch. - Suffix uses a 9007C0 limit switch. Fuse Puller Kits Kit consists of three fuse pullers as required for a three-pole fusible V or 0 V heavy duty switch. Kits can be installed in switches manufactured after February, Fuse pullers are supplied as standard equipment on NEMA Types 1 and 1K; NEMA Types 4, 4X, stainless steel; NEMA Type 4X fiberglass reinforced polyester, and Krydon switches through A. See pages through 6 for catalog numbers. Optional Compression Lugs Refer to page 8 for applicable options. Key Interlock System Interlocks are used to prevent the authorized operator from making an unauthorized operation. The key interlock system is a simple and easy method of applying individual key interlock units and assemblies to the above equipment so as to require operation in a predetermined sequence. UL Listed. They are not available on hazardous location devices (NEMA Types 7 or 9) or fiberglass reinforced polyester (NEMA Type 4X). Use these suffixes on switch catalog numbers: KI = 1 lock per switch KI = 1 lock with cylinders per switch KIKI = separate locks per switch Key Interlock System NOTE: Factory-installed only on heavy duty safety switches. 09 Schneider Electric 11/09 1

22 Lock-Off Guard Available field-installed only, the lock-off guard works by covering the lockout/tagout opening whenever the switch is in the ON position. This prevents a padlock from being inadvertently inserted into the switch lockplate. The device is designed to help prevent accidental misapplication of a lockout device. These kits are marked curus (UL Component Recognized) for fieldinstallation. Table 1: Lock-Off Guard Applications Switch Rating A A V A 0 V and 0 A Kit Catalog Number LOGK1 LOGK Internal Barrier Kits Lock-Off Guard Shown Internal Barrier Internal Barrier Kits provide an additional barrier that helps prevent accidental contact with live parts. Field-installed transparent barriers do not restrict visual inspection of the switch. Barriers provide IEC9 IPX finger safe protection when door of enclosed disconnect switch is open. Convenient door allows use of test probes without accessing fuses and replacement of fuses without removing barrier. Barrier can also be used with the skirt kit to enclose a panel mounted Type 94 disconnect. Table 1: Catalog Number Internal Barrier Kits Description Safety Switch Application (F Series Only) 94 Type T Disconnect Application SS0 Interior Barrier for A / 0 Vac A Safety Switch 1 Vac A NA Interior Barrier for A 0 Vac A SS06 Safety Switch, or 0 Vac A A 94 Switch 0 Vac A SS Interior Barrier for A Safety Switch or / 0 Vac A 0 Vac A A 94 Switch SS Interior Barrier for 0 A Safety Switch / 0 Vac 0 A NA Skirt Kit to Enclose or 0 Vac A SS06SK A 94 Switch NA (requires SS06) 0 Vac A SSSK Skirt Kit to Enclose A 94 Switch (requires SS) NA 0 Vac A 1 Requires arc shield on V switches be changed to 0 V arc suppressor. 11/09 09 Schneider Electric

23 11/09 09 Schneider Electric Table 14: Accessories for Current Series Heavy Duty Safety Switches Catalog Number Series Electrical Interlock (1 Contact) Electrical Interlocks ( Contacts) Class R Kits Solid Neutral (Al/Cu) Solid Neutral (Cu Only) Grounding Kit (Al) Grounding Kit (Cu) Fuse Puller Receptacle Plugs HXFA H1A H1AWK H1DS E1 EIK01 EIK01 EK01 EIK0 EIK0 EK0 RFK0L RFK0L HRK SN SN0 SN0 HSN SN0C SN0C HSNC GTK0 GTK0 PKGTA1 GTK0C GTK0C PKO6GTC1 H1N H1NRB HA HAWK EIK01 EIK01 EIK01 EIK01 EIK0 EIK0 EIK0 EIK0 RFK0L RFK0L RFK0L RFK0L SN0 SN0 SN0C SN0C SN0C SN0C GTK0 GTK0 GTK0 GTK0 GTK0C GTK0C GTK0C GTK0C FPK0 FPK0 HDS HN HNRB HA EIK61 EIK01 EIK01 EIK6 EIK0 EIK0 HRK RFK0L RFK0L RFK HSN SN06 HSNC SN0C SN0C PKGTA1 GTK0 GTK0 PKOGTC1 GTK0C GTK0C FPK0 FPK0 HAWK HDS HN HNRB 01 0 RFK HRK RFK RFK SN06 HSN HSNC FPK06 FPK06 H4A H4AWK H4DS H4N HRK HRK HRK HRK H0SN H0SN H0SN H0SNC H0SNC H0SNC H0SNC H4NRB H HAWK HDS E 01 0 HRK H0SNC HN HNAWK HNDS HNR HR HXKA H6 H6AWK C SNA H6DS H6N H6AWK H6NDS H6NR H6R H7 H7AWK H800SN H800SN H7N H7NAWK H7NR H7R H800SN H8 H8AWK H8N H8NAWK HSN HSN PKOGTA8 PKOGTA8 PKOGTA8 PKOGTA8 H8NR H8R H6 H6AWK HSN PKOGTA8 PKOGTA8 H6DS H6R H66 H66A H66AWK H66DS H66R H H800SN HAWK HNAWK HR H68 H800SN H800SN HSN H68AWK H68NAWK H68R H1A EIK01 EIK0 RFK0L HSN HN SN0 SN0C GTK0 GTK0C H1AWK H1DS H1N H1NRB EIK01 EIK01 EIK01 EIK01 EIK0 EIK0 EIK0 EIK0 RFK0L HRK RFK0L RFK0L SN0 HSN SN0C HSNC SN0C SN0C GTK0 PKGTA1 GTK0 GTK0 GTK0C PKOGTC1 GTK0C GTK0C FPK0 FPK0 Continued on next page

24 09 Schneider Electric 4 11/09 Table 14: Accessories for Current Series Heavy Duty Safety Switches Catalog Number Series Electrical Interlock (1 Contact) Electrical Interlocks ( Contacts) Class R Kits Solid Neutral (Al/Cu) Solid Neutral (Cu Only) Grounding Kit (Al) Grounding Kit (Cu) Fuse Puller Receptacle Plugs HA HAWK HDS HN EIK01 EIK01 EK61 EIK01 EIK0 EIK0 EIK6 EK0 RFK0L RFK0L HRK RFK0L SN0 SN0 HSN SN0C SN0C HSNC SN0C GTK0 GTK0 PKGTA1 GTK0 GTK0C GTK0C PKO6GTC1 FPK0 HNRB HA HAWK HDS EIK01 EK1 EIK0 0 RFK0L RFK RFK HRK SN06 SN06 HSN SN0C HSNC GTK0 GTK0C FPK0 HN HNRB H4A H4AWK EK1 EK1 0 0 RFK RFK HRK HRK H0SN H0SN H0SNC H0SNC FPK06 FPK06 H4DS H4N H4NRB H EK1 EK1 EK HRK HRK HRK H0SN H0SNC H0SNC H0SNC HAWK HDS HN HNAWK HNDS HNR HR H6 E1 H6AWK H6DS H6N H6NAWK E E H6NDS H6NR H6R H7 H800SN H7AWK H7N H7NAWK H7NR H800SN H7R H8 H8AWK H8N H800SN HSN HSN PKOGTA8 PKOGTA8 PKOGTA8 H8NAWK H8NR H8R H61 EIK01 EIK0 RFK0 HSN SN0 SN0C PKOGTA8 PKOGTA8 PKOGTA8 GTK0 GTK0C FPK0 H61-A H61-AWK H61A H61AWA EIK01 EIK0 RFK06 RFK06 RFK0H RFK06 SN06 SN06 SN0. SN0C GTK0 GTK0C ACP4BC H61AWC H61AWK H61DF H61DS F1 EIK TC EK01 EIK0 9999TC EIK0 RFK06 RFK0H RKF06 HRKH SN0 HSN HSN H0C HSNC HSNC GTK0 PKGTA1 GTK0C PKOGTC1 APJ48 H61DSWC H61DSWA H61DX H61N F1 EK01 K TC EIK01 EIK0 EIK0 HRKH HRKH RFK06 RFK0H HSN HSNC SN0C GTK0 GTK0C FPK0 APJ48 ACP4BC H61NRB H61RB H61WA H61WC EIK01 EIK01 EIK0 EIK0 RFK0H RFK0H RFK06 RFK06 SN0 SN06 SN0C SN0C GTK0 GTK0 GTK0C GTK0C FPK0 FPK0 FPK06 FPK06 ACP4BC APJ48 H6 H6A H6AWA H6AWC RFK06H RFK06H RFK06H RFK06H SN06 SN06 SN06 SN06 FPK06 ACP4BC APJ648 H6AWH H6AWK H6DF H6DS F1 9999TC EK TC EK6 RFK06H RFK06H RFK06H HRKH SN06 SN06 HSN HSN HSNC HSNC PKGTA1 PKOGTC1 SD1781 H6DSWA H6DSWK H6DS H6N F1 EK61 EK TC EK6 EK6 9999TC EK0 HRKH HRKH RFK06H RFK06H HSN HSNC FPK06 ACP4BC APJ648 Continued on next page

25 11/09 09 Schneider Electric Table 14: Accessories for Current Series Heavy Duty Safety Switches Catalog Number Series Electrical Interlock (1 Contact) Electrical Interlocks ( Contacts) Class R Kits Solid Neutral (Al/Cu) Solid Neutral (Cu Only) Grounding Kit (Al) Grounding Kit (Cu) Fuse Puller Receptacle Plugs H6NRB H6RB H6WA H6WC RFK06H RFK06H RFK06H RFK06H SN06 SN06 SN06 FPK06 FPK06 FPK06 FPK06 ACP4BC APJ648 H6WH H6 H6A H6AWA RFK06H RFK RFK RFK SN06 SN06 SN06 FPK06 FPK06 SD1781 ACP4CD H6AWC H6AWK H6DF H6DS F1 9999TC EK1 9999TC 0 RFK RFK RFK HRK SN06 SN06 HSN HSNC H6DSWA H6DSWC H6DX H6N F1 EK1 EK1 9999TC TC HRK HRK RFK RFK SN06 FPK06 ACP4CD APJ487 H6NRB H6RB H6WA H6WC RFK RFK RFK RFK SN06 FPK06 FPK06 FPK06 FPK06 ACP4CD APJ487 H64 H64A H64AWK H64DF E R R9 HRK HRK HRK HRK H64DS H64N H64NA H64NAWK EK1 EK1 EK1 EK1 EK EK EK EK HRK HRK HRK HRK H0SN H0SN H0SNC H64NDS H64NRB H64RB H6 EK1 EK1 EK1 EK EK EK HRK HRK HRK H0SN H0SNC H6AWK H6DS H6N H6NAWK H6NDS H6NR H6R H66 H66AWK H66DS H66N H66NAWK H66NDS H66NR H66R H67 H800SN H67AWK H67N H67NAWK H67NR H800SN H67R H68 H68AWK H68N H800SN HSN HSN PKOGTA8 PKOGTA8 PKOGTA8 H68NAWK H68NR H68R H461 RFK06 HSN PKOGTA8 PKOGTA8 PKOGTA8 FPK06 H461AWK H46 H46AWK H46DS EK61 EK6 RFK06 RFK06H RFK06H HRKH PKGTA1 PKOGTC1 FPK06 H46 H46AWK H46DS H464 EK1 EK1 EK EK RFK RFK HRK HRK SN06 FPK06 H464AWK H464DS H46 H46AWK EK1 EK1 EK EK HRK HRK Continued on next page

26 09 Schneider Electric 6 11/09 Table 14: Accessories for Current Series Heavy Duty Safety Switches Catalog Number Series Electrical Interlock (1 Contact) Electrical Interlocks ( Contacts) Class R Kits Solid Neutral (Al/Cu) Solid Neutral (Cu Only) Grounding Kit (Al) Grounding Kit (Cu) Fuse Puller Receptacle Plugs H466 HXFA H66AWK H66DS F1 EK1 0 RFK HRK SNA H664DS H664AWK HU6 HU6AWK EK1 EK1 0 0 HRK HRK HU6DS HU6R HU66 HU66AWK HU66DS HU66R HU HUAWK HUR HU68 HU68AWK HU68R H800SN H800SN HSN HSN PKOGTA8 PKOGTA8 HU61 HU61A HU61AWA HU61AWC EIK01 EIK01 EIK0 EIK0 SN0 SN0 SN0C SN0C GTK0 GTK0 GTK0C GTK0C ACP4BC APJ48 HU61AWK HU61DF HU61DS HU61DSWA F1 EIK TC EK01 EK01 EIK0 9999TC EK0 EK0 SN0 HSN HSN SN0C HSNC HSNC GTK0 PKGTA1 GTK0C PKOGTC1 ACP4BC HU61DSWC HU61DX HU61RB HU61WA F1 EK TC EIK01 EK6 9999TC EIK0 HSN SN0 HSNC SN0C GTK0 GTK0C APJ48 ACP4BC HU61WC HU6 HU6A HU6AWA SN06 SN06 SN06 SN06 APJ48 ACP4BC HU6AWC HU6AWH HU6AWK HU6DF F1 9999TC 9999TC SN06 SN06 SN06 HSN HSNC APJ648 SD1781 HU6DS HU6DSWA HU6DSWC HU6DX F1 EK61 EK61 EK TC EK6 EK6 EK6 9999TC HSN HSN HSNC HSNC PKGTA1 PKOGTC1 ACP4BC APJ648 HU6RB HU6WA HU6WC HU6WH SN06 SN06 ACP4BC APJ648 SD1781 HU6 HU6A HU6AWA HU6AWC SN06 SN06 ACP4CD APJ487 HU6AWK HU6DF HU6DS HU6DSWA 9999TC TC 0 0 SN06 SN06 HSN HSNC ACP4CD HU6DSWC HU6DX HU6RB HU6WA F TC TC SN06 SN06 APJ487 ACP4CD HU6WC HU64 HU64A HU64AWK EK1 EK1 EK1 EK EK EK H0SN H0SN H0SN H0SNC H0SNC H0SNC APJ487 HU64DF HU64DS HU64RB HU6 E1 9999R8 EK1 EK1 9999R9 EK EK H0SN H0SN H0SNC H0SNC Continued on next page

27 7 11/09 09 Schneider Electric Table 14: Accessories for Current Series Heavy Duty Safety Switches Catalog Number Series Electrical Interlock (1 Contact) Electrical Interlocks ( Contacts) Class R Kits Solid Neutral (Al/Cu) Solid Neutral (Cu Only) Grounding Kit (Al) Grounding Kit (Cu) Fuse Puller Receptacle Plugs HU6AWK HU6DS HU6R HU66 HU66AWK HU66DS HU66R HU67 H800SN HU67AWK HU67R HU68 HU68AWK H800SN H800SN HSN HSN PKOGTA8 PKOGTA8 HU68R HU461 HU461AWK HU461DS E1 EK61 EK61 EK6 EK6 HSN PKOGTA8 PKGTA1 PKGTA1 PKOGTC1 PKOGTC1 HU46 HU46AWK HU46DS HU46 EK61 EK6 PKGTA1 PKOGTC1 HU46AWK HU46DS HU464 HU464AWK EK1 EK1 EK1 EK EK EK HU464DS HU46 HU46AWK HU466 EK1 EK HU661AWK HU661DS HU66AWK HU66DS EK01 EK61 EK0 EK6 PKGTA1 PKGTA1 PKOGTC1 PKOGTC1 HU66AWK HU66DS HU664DS HU664RWK EK1 EK1 EK1 EK EK EK

28 General Information General Information 8 11/09 UL Listed Maximum Short Circuit Current RatingsAC Only NOTE: Consult the wiring diagram of the switch to verify the UL Listed short circuit current rating. Table : Fusible Short Circuit Current Ratings Heavy Duty Safety Switch UL Listed Short Circuit UL Listed Fuse Class Type Current Ratings H, K ka Fusible R, J, L 0 ka 1 1 On 0 V 0 A switches,,000 A max. on corner grounded delta when protected by Class J or R fuses. Table 16: Non-Fusible Safety Switches Heavy Duty Switch Rating Fuse or Circuit Safety Switch (A) 1 Breaker Type Type -Phase Vac 480 Vac 0 Vac Any brand circuit breaker All H, K Up to ka R,T,J.L 0 ka 0 ka 0 ka H 6 ka ka ka FA 14 ka 14 ka 14 ka Non-Fusible FH 18 ka 18 ka 18 ka Switches 0 H, J 6 ka ka ka 0 KA 0 LA ka ka ka 0 MA 0 KH 0 LH ka ka ka 0 MH 1 Applies to NEMA Types 1, R, 4X stainless, 1 switches. Ampere rating of fuse or circuit breaker not to exceed switch ampere rating. All H and J circuit breakers are acceptable, but will only support the noted Short Circuit Current Rating. Table 17: Terminal Lug Data (NEMA Types 1, R, 4, 4X,, 7, 9, 1) 1 Rating (A) Conductors Per Phase and Neutral Wire Range Wire Bending Space Per NEC Table 1.6 AWG/kcmil Lug Wire Range AWG/kcmil Optional Versa-Crimp Compression Lug Field-Installed (Al) or 14 6 (Cu) 1 (Al) 14 (Cu) solid or or 14 (Cu) 14 (Cu) stranded 4 14 (Al) or 1 14 (Cu) 1 (Al) or 14 (Cu) 1 1 1/0 (Al) or 14 1/0 (Cu) 1 1/0 (Al) or 14 1/0 (Cu) VCEL0114S (Al/Cu) 6 0 (Al/Cu) VCEL016H1 VCEL01H1 1 1/0 7 (Al/Cu) 6 1/0 7 (Al/Cu) or 0 or or and VCEL016H1 7 1/0 0 (Al/Cu) 1/0 0 (Al/Cu) and VCEL01H1 0 /0 0 (Al/Cu) /0 0 (Al/Cu) VCEL01H1 800 /0 7 (Al/Cu) /0 7 (Al/Cu) H8LKE 8 4 /0 7 (Al/Cu) /0 7 (Al/Cu) H1LKE 8 1 A switches suitable for C or C conductors. 0 A switches suitable for o C conductors. For NEMA Types 1 and R only. HU461AWK 14 6 AWG (Cu). 4 HXFA 14 6 AWG (Cu). HXKA 4 AWG 0 kcmil (Cu). 6 Maximum wire range is (1) 0 kcmil or () 0 kcmil Al/Cu on NEMA Type 4X Stainless and NEMA Type 1. 7 Order two PK16KN mounting kits when installing VCEL016H1 lugs. Only one kit is required on two-pole switches. 8 See Digest 1 page 1, 800 and A compression lug kits for additional information. 09 Schneider Electric

29 General Information Table 18: A Heavy Duty Rating Catalog Number H1DS H1A H1AWK H1N H1NRB H1DS H1A H1AWK H1N H1NRB H61 H61RB H61DS H61A H61AWK H61A H61AWK H61N H61NRB H461 H461DS H461AWK HU61 HU61RB HU61DS HU61A HU61AWK HU461 HU461DS HU461AWK 1 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Series Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. E1 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø 1/ 1/ 1/ 1/ 1/ 1/ 1/ 1-1/ 1-1/ 1 1-1/ 1 1-1/ 1 1-1/ 1 1-1/ 1 1-1/ 1 1-1/ 1 1-1/ 1 1-1/ Use both outer switching poles. For corner grounded only, install neutral and use switching poles for ungrounded conductors. Standard hp rating Schneider Electric 11/09 9

30 General Information Table 19: A Heavy Duty Ratings Catalog Number HDS HA HAWK HN HNRB HDS HA HAWK HN HNRB H6 H6RB H6DS H6A H6AWK H6N H6NRB H46 H46DS H46AWK HU6 HU6RB HU6DS HU6A HU6AWK HU46 HU46DS HU46AWK HU66DS HU66AWK 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Series Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø 1-1/ 1-1/ 1-1/ 1-1/ 1-1/ 1-1/ 1-1/ 1-1/ Use both outer switching poles. For corner grounded delta only, install neutral and use switching poles for ungrounded conductors. Standard hp rating. 4 hp maximum on a corner grounded delta system. hp maximum on a corner grounded delta system. 6 Use C N.O. 4 Cu or N.O. Al conductors /09 09 Schneider Electric

31 General Information Table : A Heavy Duty Ratings Catalog Number HDS HAWK HA HN HNRB HDS HA HAWK HN HNRB H6 H6RB H6DS H6A H6AWK H6N H6NRB H46 H46DS H46AWK H66DS H66AWK HU6 HU6RB HU6DS HU6A HU6AWK HU46 HU46DS HU46AWK HU66DS HU66AWK Series 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø Use both outer switching poles. For corner grounded delta only, install neutral and use switching poles for ungrounded conductors. Standard hp rating. 4 Use C No. 1 copper conductor only. hp maximum on corner grounded delta. 6 Use C N.O. 4 Cu or N.O. Al conductors. 09 Schneider Electric 11/09 1

32 General Information 09 Schneider Electric 11/09 Table 1: 0 A Heavy Duty Ratings Catalog Number Series 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø H4DS H4A H4AWK H4N H4NRB 1 1 H4DS H4A H4AWK H4N H4NRB H64 H64RB H64DS H64A H64AWK H64N H64NRB H464 H464DS H464AWK H664DS H664AWK HU64 HU64RB HU64DS HU64A HU64AWK HU464 HU464DS HU46AWK HU664DS HU664AWK

33 General Information 11/09 09 Schneider Electric Table : 0 A Heavy Duty Ratings Catalog Number Series 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø H HR HDS HAWK HN HNR HNDS HNAWK H HR HDS HAWK HN HNR HNDS HNAWK H6 H6R H6DS H6AWK H6 H6R H6DS H6AWK H6N H6NR H6NDS H6NAWK 1 1 H46 H46AWK HU6 HU6R HU6DS HU6AWK HU6 HU6R HU6DS HU6AWK 1 1 HU46 HU46AWK 1 For corner grounded only, install neutral and use switching poles for ungrounded conductors. Not suitable for use as service equipment.

34 General Information 09 Schneider Electric 4 11/09 Table : 0 A Heavy Duty Ratings Catalog Number Series 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø H6 H6R H6DS H6AWK H6N H6NR H6NDS H6NAWK H6 H6R H6DS H6AWK H6N H6NR H6NDS H6NAWK H66 H66R H66DS H66AWK H66 H66R H66DS H66AWK H66N H66NR H66NDS H66NAWK H466 HU66 HU66R HU66DS HU66AWK HU66 HU66R HU66DS HU66AWK HU466 1 For corner grounded only, install neutral and use switching poles for ungrounded conductors. Not suitable for use as service equipment.

35 General Information 11/09 09 Schneider Electric Table 4: 800 A Heavy Duty Ratings Catalog Number Series 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø H7 H7R H6AWK H7N H7NR H7NAWK H7 H7R H7AWK H7N H7NR H7NAWK HN HR HAWK H67 H67R H67AWK H67N H67NR H67NAWK HU HUR HUAWK HU67 HU67R HU67AWK Table : A Heavy Duty Ratings Catalog Number Series 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø H8 H8R H8AWK H8N H8NR H8NAWK H8 H8R H8AWK H8N H8NR H8NAWK H68N H68R H68AWK H68 H68R H68AWK H68N H68NR H68NAWK HU68 HU68R HU68AWK HU68 HU68R HU68AWK

36 General Information Table 6: Catalog Number Specialty Switches 1 Vac Vac 480 Vac 0 Vac Vdc Series Max. Max. Max. Max. Max. hp Ratings 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Fiberglass Reinforced Polyester EnclosuresNEMA Type 4X H61DF H6DF H6DF H64DF HU61DF HU6DF HU6DF HU64DF F1 F1 F1 E1 F1 F1 E1 E1 Krydon Enclosures H61DX H6DX H6DX HU61DX HU6DX HU6DX F1 F1 F1 F1 F1 F NEMA Types 7 and 9 Enclosures HXFA HXFA11 HXFA HXFA11 E1 E1 E1 E1 1-1/ / HXKA C Use outer switching poles. For corner grounded only, install neutral and use switching poles for ungrounded conductors. hp rating on corner grounded delta system. 4 hp rating on corner grounded delta system. Standard hp rating. 6 Standard hp rating: hp. 7 Standard hp rating: hp. 8 Standard hp rating: hp. 9 hp rating on corner grounded delta system /09 09 Schneider Electric

37 General Information Table 7: Receptacle Switches Catalog Number H61WA H61DSWA H61AWA HU61WA HU61DSWA HU61AWA H61WC H61DSWC H61AWC HU61WC HU61DSWC HU61AWC H6WA H6DSWA H6AWA HU6WA HU6DSWA HU6AWA H6WC H6DSWC H6AWC HU6WC HU6DSWC HU6AWC H6WH H6AWH HU6WH HU6AWH H6WA H6DSWA H6AWA HU6WA HU6DSWA HU6AWA H6WC H6DSWC H6AWC HU6WC HU6DSWC HU6AWC 1 Vac Vac 480 Vac 0 Vac Vdc Series Max. Max. Max. Max. Max. hp Ratings 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø / Use both outer switching poles. Two standard hp rating. Standard hp rating. 4 Fifteen hp maximum on a corner grounded delta system. Not applicable for corner grounded delta. 6 Thirty hp maximum on a corner grounded delta system. 7 Use C N.O. 4 Cu or N.O. Al conductors Schneider Electric 11/09 7

38 General Information 09 Schneider Electric 8 11/09 W W W/H H H W/H D D Typical NEMA Type 1 Typical NEMA Type R Table 8: Dimensions Catalog Number Series Approximate Dimensions H W W/H D in. mm in. mm in. mm in. mm H1N H1NRB HN HNRB HN HNRB H4N H4NRB H, N HNR, R H6, N H6NR, R H7, N H7NR, R H8, N H8NR, R H6 H6R H66 H66R H HR H68 H68R H1N H1NRB HN HNRB HN HNRB H4N H4NRB H, N HR, NR H6, N H6R, NR H7, N H7R, NR H8, N H8R, NR H61, N H61- H61NRB, RB H61WA H61WC H6, N H6NRB, RB H6WA H6WC H6WH H6, N H6NRB, RB H6WA H6WC

39 General Information 9 11/09 09 Schneider Electric W W W/H H H W/H D D Typical NEMA Type 1 Typical NEMA Type R Table 9: Dimensions Catalog Number Series Approximate Dimensions H W W/H D in. mm in. mm in. mm in. mm H64 H64N H64NRB H64RB H6, N H6R, NR H66, N H66NR, R H67, N H67NR, R H68, N H68NR, R H461 H46 H46 H H46 H466 HU6 HU6R HU66 HU66R HU HUR HU68 HU68R HU61 H61RB HU6 HU6RB HU6WH HU HU6RB HU64 HU64RB HU6 HU6R HU66 HU66R HU HU67R HU68 HU68R HU461 HU HU46 HU HU46 HU

40 General Information Table : Dimensions Catalog Number Series Approximate Dimensions H W W/H D W W/H Typical NEMA Types 4, 4X,, 1, and 1K W H Typical NEMA Type 4X Fiberglass Reinforced Polyester and Krydon W H H D D D Typical NEMA Types 7 and 9 H461AWK H461DS H46AWK H46DS H1AWK, A H1DS H1-AWK HAWK, A HDS HAWK, A HDS H4AWK, A H4DS HAWK, DS HNAWK, NDS in. mm in. mm in. mm in. mm HXKA C H6AWK, DS H6NAWK, NDS H7AWK, NAWK H8AWK, NAWK H6AWK, DS H66AWK, A, DS HAWK, NAWK H68AWK, NAWK H1AWK, A H1DS HAWK, A HDS HAWK, A HDS H4AWK, A, DS HAWK, DS HNAWK, NDS H6AWK, DS H6NAWK, NDS H7AWK, NAWK H8AWK, NAWK H61AWA H61AWC H61AWK, A, DS H61DF H61DX F H61-AWK, A H6AWK, A H6DS H6AWA H6AWC H6AWH H64, N H64RB, NRB H6, N H6R, NR H66, N H66NR, R H67, N H67NR, R H68, N H68NR, R /09 09 Schneider Electric

41 General Information Table 1: Dimensions Catalog Number Series Approximate Dimensions H W W/H D W W/H Typical NEMA Types 4, 4X,, 1, and 1K W H Typical NEMA Type 4X Fiberglass Reinforced Polyester and Krydon W H H D D D Typical NEMA Types 7 and 9 HXFA HXFA H1AWK, A H1DS H1-AWK HAWK, A HDS HAWK, A HDS H4AWK, A H4DS HAWK, DS HNAWK, NDS E1 in. mm in. mm in. mm in. mm HXKA C H6AWK, DS H6NAWK, NDS H7AWK, NAWK H8AWK, NAWK H6AWK, DS H66AWK, A, DS HAWK, NAWK H68AWK, NAWK H1AWK, A H1DS HAWK, A HDS HAWK, A HDS H4AWK, A, DS HAWK, DS HNAWK, NDS H6AWK, DS H6NAWK, NDS H7AWK, NAWK H8AWK, NAWK H61AWA H61AWC H61AWK, A H61DS H61DF H61DX H61-AWK, A H6AWK, A H6DS H6AWA H6AWC H6AWH H64, N H64RB, NRB H6, N H6R, NR H66, N H66R, NR H67AWK, NAWK H68AWK, NAWK F Schneider Electric 11/09 41

42 General Information Table : Dimensions Catalog Number Series Approximate Dimensions H W W/H D W W/H Typical NEMA Types 4, 4X,, 1, and 1K W H Typical NEMA Type 4X Fiberglass Reinforced Polyester and Krydon W H H D D D Typical NEMA Types 7 and 9 H461AWK H46AWK H46DS H46AWK H46DS H464AWK H464DS in. mm in. mm in. mm in. mm H46AWK H66AWK H66DS H664AWK H664DS HU6AWK,DS HU66AWK, DS HUAWK HU68AWK HU61AWK, A HU61DS HU61DSWA HU61DSWC HU61DF HU61DX HU6AWH HU6AWK, A HU6DS HU6DSWA HU6DSWC HU6DF HU6DX HU6AWA HU6AWC HU6AWK, A HU6DS HU6DF HU6DX F1 F1 F HU64DF E HU64AWK, A HU64DS, SS HU6AWK, DS HU66AWK, DS HU67AWK HU68AWK HU461AWK HU461DS HU46AWK HU46DS HU46AWK HU46DS HU464AWK HU464DS HU46AWK H66AWK H66DS H664AWK H664DS, RWK /09 09 Schneider Electric

43 Double Throw Safety Switches DOUBLE THROW SAFETY SWITCHES CONTENTS Product Description Construction Enclosures Accessories... 4 Application... 4 Standards Technical Data Service Grounding Kit Solid Neutral Assembly Electrical Interlocks Class R Fuse Kits... Lock-On Provision... Rain-Proof Bolt-On Hubs... Watertight Hubs... Dimensions Schneider Electric 11/09 4

44 Double Throw Safety Switches Product Description Double throw safety switches are designed to transfer a load from one power source to another power source. A F Series switches can be field-converted to transfer a power source from one load to another. Construction A DT, DTU (Series F) NEMA Type 1 Modular-design switch handle, lock -plate, and switch mechanism; line and load bases are available for field replacement Meets NEMA hp ratings UL Listed short circuit current ratings up to 0 ka (using Class R, J, or T fuses see UL Listed Short Circuit Current Ratings table on page 4) UL Listed as suitable for use as service equipment Fusible and non-fusible switches available May be padlocked in the ON or OFF position Padlock provisions in the center OFF position on 8,000, 9,000, DT, and DTU lines Padlock provisions in both ON positions on 9,000 line Visible blades for positive indication that the switch is OFF Electrical interlock and neutral assembly (for two- and three-pole switches) kit is available for field-installation Quick-make, quick-break operating mechanism on F Series, 8,000, DT, and DTU lines. Load make/break Slow-make, slow-break operating mechanism on 9,000 line. Non-load make/break Lugs suitable for aluminum or copper conductors. See page 46 for additional lug data Dual cover interlock on DT and DTU F Series and NEMA Type 1 8,000 line E Series devices, with defeat mechanism NEMA Type R top endwalls on 0 A switches have bolt-on hub provisions Tangential knockouts alleviate the need for conduit offsets or bends Type 4 Stainless Steel (NEMA Types 4, 4X, and ) Enclosures Indoor general purpose (NEMA Type 1) Outdoor general purpose (NEMA Type R) Indoor dusttight, driptight (NEMA Type 1) Indoor, outdoor watertight, dusttight (NEMA Types 4, 4X, and ) Gray baked enamel finish electrodeposited on clean, phosphatized steel (NEMA Types 1, R, and 1) 8,000 Line NEMA Type /09 09 Schneider Electric

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D 2 N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D 2 N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Selection Guide Contents Descriptions Page General Information Features and Benefits 2-3 Product Illustrations General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Heavy Duty Safety

More information

Safety Alert: Square D Safety Switches

Safety Alert: Square D Safety Switches Safety Alert: Square D Safety Switches Be Sure to Inspect Your Installed Units for Defects Schneider Electric has issued an offer safety alert on the Square D safety switch due to electrical shock hazard

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................

More information

1.1. Switching Devices

1.1. Switching Devices . Switching Devices Six-Pole Motor Circuit Contents Description Page Product Overview......................... V2-T-2 General Duty............................. V2-T-24 Heavy-Duty..............................

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

1.1. Switching Devices. Safety Switches

1.1. Switching Devices. Safety Switches . Catalog Number Eaton General Electric Siemens Square D Fusible, Three-Pole, Four-Wire, 20 Vac, NEMA 3R 30 DH32NRK TH32R HF32NR H32NRB 60 DH322NRK TH322R HF322NR H322NRB 00 DH323NRK TH323R HF323NR H323NRB

More information

Solar Combiner Solutions

Solar Combiner Solutions Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from

More information

Section 3. Table of Contents. Safety Switches. General Duty. Light Duty. Heavy Duty. Double Throw 3-1

Section 3. Table of Contents. Safety Switches. General Duty. Light Duty. Heavy Duty. Double Throw 3-1 Table of Contents Section Safety es General uty General uty & Not -2 Application ata and imensions - Standards: UL 98 Enclosed and ead Front es. UL Listed under File E2875. NEMA Standards Publication KS1.

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch . Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A

More information

Solar Combiner Solutions

Solar Combiner Solutions Solar Combiner Solutions Providing combiners and disconnects that offer superior resistance and durability from harsh weather and abusive solar environments Solar Technology Leading the way in Solar Technology

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

Light Duty. General Duty. Heavy Duty. Double Throw Vdc Photovoltaic Heavy Duty Disconnect Switch. Standards:

Light Duty. General Duty. Heavy Duty. Double Throw Vdc Photovoltaic Heavy Duty Disconnect Switch. Standards: Table of Contents Section Safety Switches Light uty Fusible -2 Application ata and imensions - Standards: UL 98 Enclosed and ead Front Switches. UL Listed under File E2875. NEMA Standards Publication KS1.

More information

Air Conditioning Disconnects Molded Case Switch

Air Conditioning Disconnects Molded Case Switch Air Conditioning Disconnects Molded Case Switch Catalog 3150CT0401R08/09 2009 Class 3150 QO200TR QO200TRNM CONTENTS Description............................................. Page..........................................

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description

More information

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles Compatible with UL 1686 C1 Pin & Sleeve Devices Safer. Easier. Better. MENNEKES Non-Metallic MSR Switched and Interlocked

More information

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

Instructions for Installation, Operation and Maintenance of: WSRD Interlocked Receptacles 30, 60 & 100 Ampere 331114-1 INSTRUCTION SHEET Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere Read instructions carefully and with full understanding for safe

More information

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch Double-Throw, continued Ampere Rating Catalog Number Selection Safety Switch Catalog Number Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA X 30 N/A N/A N/A N/A

More information

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical

More information

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com AR331 30 Amp Pin & Sleeve Recpt 3-W 3-P 250VDC/600vac Cooper Crouse-Hinds Catalog Number

More information

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC) 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC) Appleton/Oz Gedney Catalog Number ACP1034CD Manufacturer Appleton/Oz Gedney

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Arktite Heavy Duty Circuit Breaking Plugs and Connectors Arktite Heavy Duty Circuit Breaking Plugs and Connectors 60 A, 600 VAC/250 VDC, 50**-400 hertz Dimensions Page 968 1P Plug Connector Mating APJ Plugs Mating APR Connectors Style 1 Description Cat. # Dia.

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC) 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC) Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit

More information

Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $

Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $ January 1 Vol. 1, ef. No. [0247] eavy uty, Fusible, - 361FK NEMA 12 Enclosure Industrial ust-tight NEMA 4 Enclosure atertight, Painted Steel Enclosure Corrosion esistant, Stainless Steel 2-Pole 40V AC

More information

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine eavy Industrial/ Marine Benefits builds a variety of benefits into one plug, receptacle and interlock system for your application. Safety Waterproof construction: standard neoprene O ringed interior components

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

Quik-Spec. Section Contents

Quik-Spec. Section Contents Section Contents Page Quik-Spec Coordination Panel Boards......... 238-239 Quik-Spec Power Module Switches and Panels.. 240-241 Quik-Spec DC Safety Switches.................. 242 Quik-Spec Solar Combiner

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles 1P Arktite Heavy Duty Circuit Breaking s and Receptacles Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically

More information

Selection and application guide

Selection and application guide Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas 1P Arktite Heavy Duty Circuit Breaking s and s Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically operated

More information

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION Specification Number: 26 24 13.20 Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION 26 24 13.20 SWITCHBOARDS (Long) Main Disconnect Group Mounted Fusible

More information

EPOXY POWDER COATED COPPER FREE ALUMINUM

EPOXY POWDER COATED COPPER FREE ALUMINUM 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AJA510 Alum MTG Unilet Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category Features

More information

IN2 Enclosed Switches and Circuit Breakers

IN2 Enclosed Switches and Circuit Breakers Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Enclosed Switches and Circuit Breakers Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 ARL2042 Receptacle Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Descriptions

More information

GHN424NW HHN426N HUN361AW

GHN424NW HHN426N HUN361AW GHN424NW HHN426N HUN61AW Passed The Test of Time All Murray safety switches have passed rigid testing requirements to assure reliable performance. In addition to tests designed and conducted during the

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable

More information

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

1. Division 26 Section Elevator Shunt-Trip Fused Disconnect Switches. SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1 Sect_0_Speedfax2007 /26/07 5:05 PM Page -1 SPEEDFAX TM 2007-2008 Safety Switches Contents Safety Switch Guide Form Specifications -2 Feature Comparison - Enclosure Types -4 Catalog Numbering System -5

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

Wastewater Solutions. DECONTACTOR TM Series. Featuring Meltric s. Switch Rated Plugs, Receptacles and Electrical Connectors

Wastewater Solutions. DECONTACTOR TM Series. Featuring Meltric s. Switch Rated Plugs, Receptacles and Electrical Connectors Wastewater Solutions Featuring Meltric s DECONTACTOR TM Series Switch Rated Plugs, Receptacles and Electrical Connectors Meltric DECONTACTOR TM Series Plugs & Receptacles Decontactors are a combination

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

T CLASS T FUSE BLOCKS

T CLASS T FUSE BLOCKS Ferraz Shawmut Fuse Blocks accommodate fuses up to 600A. Insulators are either of durable, glassfilled polycarbonate (GFPC) or phenolic with verified dielectric strength in excess of 2500V. Ferraz Shawmut

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Section 4 Square D QO Loadcentres

Section 4 Square D QO Loadcentres Section 4 Square D QO Loadcentres The Choice of Professionals Square D service entrance loadcentres feature the rugged design, high quality and proven performance that residential, multi-residential and

More information

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 APJ10487 100 Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac Cooper Crouse-Hinds Catalog Number Manufacturer Description

More information

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33 SECTION V INDEX Product Description Page Number Junction Boxes......................................V-V2 Meter and Instrument Enclosures.......................V24-V Control Centers.....................................V4-V9

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

Just the right switch for your application

Just the right switch for your application Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality

More information

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures 30-600 Amperes: TG and TH 800-1200 Amperes: TC Equipment Ground Kits Ampere Rating AWG/kcmil Copper AWG/kcmil Aluminum Standard Package

More information

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle Features 30-600A, 600VAC and DC ratings UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 15852 Visible blade quick make and break switching action Panel and Flange mounted assemblies

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles P Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable

More information

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous 3P Description Page No. Application/Selection 1016, 1017 Interlocked Receptacle with Disconnect Switch WSR 30, 60, 100A Aluminum 1018,

More information

Type VBII Visible Blade Disconnect Switches

Type VBII Visible Blade Disconnect Switches Type VBII Visible Blade Disconnect es Product Guide Siemens Type VBII visible blade disconnect switches meet either UL98 or UL1741 requirements and can be used in either service entrance or branch circuit

More information

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install Midwest Electric Products Safety Switches Rugged, reliable and easy to install Midwest Safety Switches Features Midwest Electric Products offers a wide variety of general duty and heavy duty safety switches,

More information

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically operated devices

More information

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. EBR Receptacle Class

More information

Safety Switch. Type VBII. cross-reference GUIDE

Safety Switch. Type VBII. cross-reference GUIDE Safety Switch Type VBII cross-reference GUIDE General Duty 240 Volt, Type 1 (Indoor) 2-Pole, 2-Wire, Fusible 2-Pole, 3-Wire, Fusible 3-Pole, 3-Wire, Fusible 3-Pole, 4-Wire, Fusible 30 Use 60 Use Use Use

More information

POWERBUS 225 Busway and Plug-In Units

POWERBUS 225 Busway and Plug-In Units Busway and Plug-In Units Class 5600 CONTENTS Schneider Electric Brands Description Page Product Descriptions.................................................. 3 POWERBUS 225 Busway System.....................................

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

Transfer switch OTEC and OTECSE open transition

Transfer switch OTEC and OTECSE open transition Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY EDSC210 -Way Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type Contact Configuration Current Rating Voltage Rating Material, Color, and

More information

!!IERVICEB.aJC IJJI SQUARE D. Power Outlet Panels. Application Data Dimensions CONTENTS. Description Class Pages

!!IERVICEB.aJC IJJI SQUARE D. Power Outlet Panels. Application Data Dimensions CONTENTS. Description Class Pages FILE: Distribution Product Catalog!!IERVICEB.aJC Power Outlet Panels CONTENTS Description Class Pages Application Data.......................... 1140........ 36 Dimensions................................

More information

Hazardous Duty Applications

Hazardous Duty Applications Hazardous Location Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Applications Russellstoll Hazardous Duty Plugs, Receptacles and Interlocks

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most up-todate disconnect

More information