Light Duty. General Duty. Heavy Duty. Double Throw Vdc Photovoltaic Heavy Duty Disconnect Switch. Standards:

Size: px
Start display at page:

Download "Light Duty. General Duty. Heavy Duty. Double Throw Vdc Photovoltaic Heavy Duty Disconnect Switch. Standards:"

Transcription

1 Table of Contents Section Safety Switches Light uty Fusible -2 Application ata and imensions - Standards: UL 98 Enclosed and ead Front Switches. UL Listed under File E2875. NEMA Standards Publication KS1. Enclosed Switches. General uty Light uty, p. -2 Fusible and Non-Fusible -2 Application ata and imensions - Standards: UL 98 Enclosed and ead Front Switches. UL Listed under File E2875. NEMA Standards Publication KS1. Enclosed Switches. eavy uty General uty, p. -2 Fusible -4 Non-Fusible -6 Special Application Enclosures -7 Mot isconnect and Receptacle Switches -8 Accessies -11 Application ata and imensions -1 Standards: UL 98 Enclosed and ead Front Switches. UL Listed under files E2875, E154828, E2505 and E UL 508 Industrial Control Equipment, file E NEMA Standards Publication KS1 Enclosed Switches (UL98 Switches Only). ouble Throw eavy uty, p. -4 Fusible and Non-Fusible -15 Accessies -18 Standards: UL 98 Enclosed and ead Front Switches. UL Listed under files E2875 (unless otherwise noted). NEMA Standards Publication KS1 Enclosed Switches (applies to Type T and TU series F only). Application ata and imensions Vdc Photovoltaic eavy uty isconnect Switch Standards: UL 98 Enclosed and ead Front Switches UL Listed under file E447 IEC Electrical IEC Mechanical NEMA standard. Publication KS-1 Enclosed Switches IP 6 and NEMA Enclosure -22 Stainless Steel eavy uty, p This document provided by Barr-Thp Electric Co., Inc

2 General uty Safety Switches L221N Light uty Class 10 / Refer to Catalog 100CT0701 Light uty Visible Blades 10 ka Sht Circuit Current Rating The Square light duty enclosed switch is ideal f home applications in disconnecting power to wkshops, hobby rooms, furnaces, and garages. Table.1: a Fusible Indo sepower Ratings Indo sepower Ratings System Fuse System Fuse Std. Max. Std. Max. 2 ire (1 Blade and Fuseholder, 1 Neutral) 120 Vac ire (2 Blades and Fuseholders, 1 Neutral) 120/240 Vac 0 Plug L111N $ /2 2 F single phase hp rating, use two switching poles. 0 Plug L211N /2a a 0 Cart. L221N /2a a General uty Up To 100 ka Sht Circuit Current Rating ith Proper Current Limiting Fusing General duty safety switches are designed f residential and commercial applications where durability and economy are prime considerations. Typical loads are lighting, air conditioning, and appliances. They are suitable f use as service equipment when equipped with a facty- field-installed neutral assembly a field-installed service grounding kit, (see Table.6) as applicable. General duty safety switches are UL Listed, File E2875, and meet exceed the NEMA Standard KS1. 22N UL Listed Sht Circuit ithstand Rating Switch Type Fuse Class Sht Circuit Rating Plug 10 ka 10 ka K 10 ka Fusible J 100 ka R 100 ka T 100 ka 10 ka K 10 ka Non- J 100 ka Fusiblea R 100 kab T 100 ka a The UL Listed sht-circuit current rating f Square general duty, not fusible switches is based on the switch being used in conjunction with fuses. Evaluation of nonfusible switches in conjunction with molded case circuit breakers above 10,000 amps has not been perfmed. F applications requiring greater protection, consider using a heavy duty safety switch. Refer to UL Listed Maximum Sht Circuit Current Ratings AC only on page -6. If a UL Listed sht-circuit current rating is required, this nonfusible switch must be replaced with a Square general duty fusible safety switch equipped with the appropriate class and size fusing. Consult the wiring diagram of the switch to verify the UL Listed shtcircuit current rating. b 50 ka f 60 A non-fusible switch. Table.2: Fusible Indo NEMA Ra Rainproof Class R Fuse Kits Field-Installedb Std. (Fast Acting One-Time Fuses) sepower Ratings Max. (ual Element Time-elay Fuses) System Fuse 1Ø Ø 1Ø Ø 2 ire (1 Blade and Fuseholder, 1 Neutral) 120 Vac 0 Plug Use Light uty evice f this Application (see below) 0 Cart. Use three-wire devices f this application. ire (2 Blades and Fuseholders, 1 Neutral) 120/240 Vac (Plug), 240 Vac (Cart.) Maximum 0 Plug 211N NRB /2 0 Cart. 221N NRB RK /2 c 7-1/2c 60 Cart. 222N NRB RFK /2c 10 15c 100 Cart. 22N NRB RFK /2 15c 15 0c 200 Cart. 224Ne NRBe RK c 60c 400 Cart. 225N NR RK g Cart. 226N NR RK ire ( Blades and Fuseholders, 1 Neutral) 240 Vac Maximum 0 Cart. 21N NRB RK /2 7-1/2 60 Cart. 22N NRB RFK /2d 10 15d 100 Cart. 2N NRB RFK /2 15d 15 0d 200 Cart. 24Ne NRBe RK d 60d 400 Cart. 25N NR RK f Class T 25NT NTR Cart. 26N NR RK f Class T 26NT NTR f Class T T27N T27NR a Bolt-on hubs Refer to page -10. b hen installed, this kit rejects all but Class R fuses. c F cner grounded delta systems only. Use switching poles f ungrounded conducts. See data bulletin 2700B0202 f additional infmation. d If cner grounded delta, use outer switching poles f ungrounded conducts. e F 200% neutral, der (1) additional neutral kit SN20A and (1) neutral jumper kit SN20NI. f Class T A general duty safety switches use 00 Vac Class T fuses and are UL Listed f use on systems with up to 100 ka available fault current. g Order Class J fuse kit: GJK600 f Class J fuses. Table.: Non-Fusible System Indo NEMA R Rainproof h sepower Ratings (Max.) 1Ø Ø 2 ire (2 Blades) 240 Vac Maximum 0 U221RB U222RB QO260NATSij QO200TRijk QO2000NSij QO2000NRBik Use P Switch Use P Switch 400 Use P Switch Use P Switch 600 Use P Switch Use P Switch ire ( Blades) 240 Vac Maximum 0 U U21RB /2 60 U U22RB U2l U2RBl U24m U24RBm n 400 U U26n h Bolt-on hubs Refer to page -10. i Enclosed molded case switch Refer to page j Includes facty-installed grounding kit. k Not service entrance rated Refer to page 1-19 f me infmation. l If a neutral assembly is required, der and field-install SN0610. m If a neutral assembly is required, der and field install a SN20A Neutral Assembly Kit. F a 200% neutral application, der and field install (2) SN20A Neutral Assembly Kits and (1) SN20NI Neutral Jumper Kit. n If a neutral assembly is required, der part number 600SN. Available f field-installation. o F single phase hp rating, use two switching poles. -2 E1A E2A iscount This document provided by Barr-Thp Electric Co., Inc

3 Table.4: Conducts Per Phase General uty Safety Switches Terminal Lug ata a ire Range ire Bending Space Per NEC Table 12.6 Lug ire Range (Al) 14 6 (Cu) 12 6 (Al) 14 6 (Cu) (Al) 14 (Cu) 10 2 (Al) 14 2 (Cu) (Al) 14 1 (Cu) 12 1/0 (Al) 14 1/0 (Cu) (Al/Cu) 6 00 (Al/Cu) NEMA R 1 2 1/0 600 (Al/Cu) 1/0 00 (Al/Cu) 2 1/0 250 (Al/Cu) (1) 1/0 750 (Al/Cu) (2) 1/0 00 (Al/Cu) (1) (Al/Cu) (2) 1/0 250 (Al/Cu) (Al/Cu) (Al/Cu) 800 /0 500 (Al/Cu) /0 500 (Al/Cu) a A switches suitable f 60 o C 75 o C conducts A switches suitable f 75 o C conducts. NOTE: Field-installed lug kits are located in the Supplemental igest page 2.2. Field-Installed Fuse Puller Kits Kit consists of three fuse pullers as required f a P, fusible, 60 and 100 A general duty switch. Kits can be installed in 60 and 100 A Series F switches. Table.5: Fuse Puller Kits escription Series F 60 A Fuse Puller Kit FPK Series F 100 A Fuse Puller Kit FPK Table.6: a b Accessies, Lug ata and imensions Class 10 / Refer to Catalog 100CT0701 (2) 12 Cu 0 PKGTA (2) 10 Al (1) 4 Al/Cu Max. (2) 12 Cu 60a PKGTA (2) 10 Al (1) 4 Al/Cu Max. (2) 12 Cu 60b GTK (2) 10 Al (1) 4 Al/Cu Max. 100 GTK (2) 1/0 Al/Cu Max. 200 PKOGTA (2) 2/0 Al/Cu Max. 400 PKOGTA2 (2) 2/0 Al/Cu Max (Two Required) Per Lug 800 PKOGTA (6) /0 Al/Cu Max. Series E switch only. Series F switch only. Field-Installed Electrical Interlock Kits Electrical interlocks f Series F A general duty safety switches and Series F 60 A fusible general duty safety switches are available in kit fm f field installation. Each kit contains instructions f proper field mounting. A pivot arm operates from switch mechanism, breaking the control circuit befe the main switch blades break. Switches with electrical interlocks installed are UL Listed. Table.7: Electrical Interlock Kit a b Field-Installed Service Grounding Kits ire Size (AG) Switch s Rating Series 60 Fb F Electrical Interlock Kit a EIK01 EIK02 EIK1 EIK Electrical interlock kit catalog numbers with -1 suffix indicates one nmally open and one nmally closed contact; -2 indicates two nmally open and two nmally closed contacts. Kits are UL Listed. Fusible series. / Table.8: Approximate imensions Series / Std. / Series Std. in. mm in. mm in. mm in. mm Pack in. mm in. mm in. mm in. mm Pack L111N E NTRc E L211N E Nc E L221N E NTc E Nc E NRc E NRBc E NTRc E Nc E U221RBc E NRBc E U222RBc E N F U21c E NRB F U21RBc E N F U22c E NRB F U22RBc E N F U2 F NRB F U2RB F N E U24 F NR E U24RB F Nc E U25c E NRc E U26c E Nc E QO200TRc G NRBc E QO260NATSc E N F QO2000NRBc E NRB F QO2000NSc E N F T27Nc E NRB F T27NRc E N F NRB F Nc E NTc E NRc E c A switches suitable f 60 o C 75 o C conducts A switches suitable f 75 o C conducts. E1 EA iscount This document provided by Barr-Thp Electric Co., Inc

4 eavy uty Safety Switches 240 Volt Class 110 / Refer to Catalog 100CT0701 Visible blade heavy duty safety switches are designed f application where maximum perfmance and continuity of service are required. All heavy duty safety switches feature quick-make, quick-break operating mechanism, a dual cover interlock and a col coded indicat handle. They are suitable f use as service equipment when equipped with a field- facty-installed neutral assembly equipment grounding kit, unless a 600Y/47 V 480 Y/277 V, 1000 A greater, solidly grounded YE system is used, per NEC eavy duty safety switches are UL Listed (except as noted), File E2875 and and meet exceed the NEMA Standard KS1. F UL Listed sht circuit current ratings, see page -6. NEMA R NEMA 4, 4X and 5 Stainless Steel 2 Table.9: 240 Volt Single Throw Fusible System Indo NEMA R Rainproof (Bolt-on ubs, page -10) NEMA 4, 4X, 5, a 04 Stainless Steel (f 16 stainless, see page -7) ust tight, atertight, Crosion Resistant (atertight ubs, page -10) 2K ith Knockouts (atertight ubs, page -10) NEMA 12, R b ithout Knockouts (atertight ubs, page -10) Std. (Using Fast Acting, One Time Fuses) sepower Ratings c 240 Vac Max. (Using ual Element, Time elay Fuses) 1Ø Ø 1Ø Ø 2-ire (2 Blades and Fuseholders) 240 Vac, 250 Vdc 0 221S A AK /2 e 7-1/2e AKf /2 5 Use three-wire devices 60 F two-wire applications 222S AK /2e e S A AK /2 15 e 15 0 e S A AK e 60 e R S AK R S AK e 200 e Rg AK Rg AK ire (2 Blades and Fuseholders, 1 Neutral) 240 Vac, 250 Vdc 0 221N NRB /2 e 7-1/2 e N NRB Use two-wire devices, 7-1/2e e 10 Field-installed solid neutral assemblies N NRB Order separately See page /2 15 e 15 0 e N NRB e 60 e N NR NS NAK e 125 e N NR NS NAK e 200 e N NRg NAK N NRg NAK ire ( Blades and Fuseholders) 240 Vac, 250 Vdc 0 21S A AK /2 7-1/ Use four-wire devices 22S A AK / F three-wire applications 2S A AK / S A AK R S AK R S AK Rg AK Rg AK ire ( Blades and Fuseholders, 1 Neutral) 240 Vac, 250 Vdc 0 21N NRB /2 7-1/ N NRB Use three-wire devices, 7-1/ Field-installed solid neutral assemblies 100 2N NRB Order separately. See page / N NRB N NR NS NAK N NR NS NAK N NRg NAK N NRg NAK ire (4 Blades and Fuseholders) Use 600 Vac devices. See page a Complete rating is NEMA, R, 4, 4X, 5 and 12. F NEMA R applications, remove drain screw from bottom endwall. b Also suitable f NEMA R application by removing drain screw from bottom endwall. c Refer to page 7-1 f additional mot application data. The starting current of mots of me than standard hsepower may require the use of fuses with appropriate time delay characteristics. d F switching dc, use two switching poles. e F cner grounded delta systems only and with neutral assembly installed. Use switching poles f ungrounded conducts. f 60 ampere switch with 0 ampere fuse spacing and clips. Must use 60 A enclosure accessies including electrical interlocks. g Suitable f NEMA 5 applications with drain screw installed. 250 Vdcd Accessies: pages -10 through -12 imensions: and R page -1 imensions: NEMA 4, 4X and 5 Stainless and page E1 iscount This document provided by Barr-Thp Electric Co., Inc

5 eavy uty Safety Switches 600 Volt Class 110 / Refer to Catalog 100CT0701 Table.10: System 600 Volts Single Throw Fusible Indo NEMA R Rainproof (Bolt-on ubs, page -10) NEMA 4, 4X, 5a 04 Stainless Steel (f 16 stainless, see page -7) ust tight, atertight, Crosion Resistant (atertight ubs, page -10) 2K ith Knockouts (atertight ubs, page -10) 2, Rb ithout Knockouts (atertight ubs, page -10) Std. (Using Fast Acting, One Time Fuses) sepower Ratingsc 480 Vac 600 Vac Max. (Using ual Element, Time elay Fuses) Std. (Using Fast Acting, One Time Fuses) Max. (Using ual Element, Time elay Fuses) Ø Ø Ø Ø ire (2 Blades and Fuseholders) 600 Vac, 600 Vdc Use three-wire devices f two-wire applications Class Fuse Provisions: Fusible Square 0 through 600 A heavy duty safety switches accept Class fuses as standard. ith Class fuses installed, the switch is UL Listed f use on systems with up to 10 ka available fault current. Class R Fuse Provisions: Fusible Square A heavy duty safety switches will accept Class R fuses as standard. A field-installed rejection kit is available which, when installed, rejects all but Class R fuses. ith the installation of the rejection kit and Class R fuses, the switch is UL Listed f use on systems with up to 200 ka available fault current. See Class R fuse kits on page -10. Class J Fuse Provisions: Provisions f installing Class J fuses are included in 0 through 400 A 600 Volt, and 100 through 400 A 240 Volt, fusible heavy duty safety switches. Conversion to Class J fuse spacing requires relocating the load side fuse base assembly from the standard Class fuse location to an alternate position as marked in the enclosure. ith Class J fuses installed, the switch is UL Listed f use on systems with up to 200 ka available fault current. Switches rated 600 A, Volt, require the addition of an adapter kit, 600J at $456. One kit per P switch. Class L Fuse Provisions: Fusible 800 A and 1200 A safety switches use Class L bolt-in fuses and are rated f use on systems with up to 200 ka at 600 Vac maximum A switches accept class L fuses from A, 800 A switches accept class L fuses from A. dce R S AK d 250d R S AK d 400d Rg AK Rg AK ire ( Blades and Fuseholders) 600 Vac, 600 Vdc e RB S A AK / f RBf Af AKf / RB S A AK RB S A AK RB S A AK R S AK R S AK R g AK Rg AK ire ( Blades and Fuseholders, 1 Neutral) 600 Vac, 600 Vdce 0 61N NRB Use three-wire devices field-installed solid neutral / N NRB assemblies. Order separately. See page N NRB N NRB NS NA NAK N NR NS NAK N NR NS NAK N NRg NAK N NRg NAK ire (4 Blades and Fuseholders) 600 Vac, 600 Vdch 2Ø 2Ø 2Ø 2Ø S AK / S AK S AK S AK AK ire (6 Blades and Fuseholders) 600 Vac h Ø Ø Ø Ø S AK S AK F applications requiring mot disconnect capability, use electrical interlock. Refer to page -10. a Complete rating is NEMA, R, 4, 4X, 5 and 12. b Also suitable f NEMA R application by removing drain screw from bottom endwall. c Refer to page 7-5 f additional mot application data. The starting current of mots of me than standard hsepower may require the use of fuses with appropriate time delay characteristics. d F cner grounded delta systems only and with neutral assembly installed. Use switching poles f ungrounded conducts. e On P devices, use two outside poles f switching dc. f 60 A switch with 0 A fuse spacing and clips. Must use 60 A enclosure accessies including electrical interlocks. g Suitable f NEMA 5 applications with drain screw installed. h Not suitable f use as service equipment. Class R Fuse Accessies: pages -10 through -12 imensions: and R page -1 imensions: NEMA 4, 4X and page -14 E1 iscount This document provided by Barr-Thp Electric Co., Inc

6 eavy uty Safety Switches Table.11: UL Listed Maximum Sht Circuit Current Ratings AC only NOTE: Consult the wiring diagram of the switch to verify the UL Listed sht circuit current rating. m System 600 Volt Single Throw Non-Fusible Indo NEMA 4, 4X, 5 a 04 Stainless Steel NEMA R (f 16 stainless, see Rainproof page -7) (Bolt-on ubs, page -10) ust tight, atertight Crosion Resistant (atertight ubs, page -10), K 10 ka Fusible R, J, L 200 kam On 600 V, 200 A switches, 100,000 A max. on cner grounded delta when protected by Class J R fuses. 2K ith Knockouts (atertight ubs, page -10) Refer to Catalog 100CT0701 2, Rb ithout Knockouts (atertight ubs, page -10) sepower Ratings (Max.) c Volts ac dcd Ø Ø 1Ø Ø 1Ø Ø ire (2 Blades) 600 Vac, 600 Vdc 0 60 Use three-wire devices 100 f two-wire applications U U265R U265S U265AK U U266R U266S U266AK U U267Re U267AK U U268Re U268AK ire ( Blades) 600 Vac, 600 Vdc 0 U U61RB U61S U61A U61AK / U61EIf U61RBEIf U61SEIf U61AEIf U61AKEIf / U612g U612RBg U612Ag U612AKg / U U62RB U62S U62A U62AK U62SEIf U U6RB U6S U6A U6AK U U64RB U64S U64A U64AK U U65R U65S U65AK U U66R U66S U66AK U U67Re U67AK U U68Re U68AK ire (4 Blades) 600 Vac, 600 Vdc k 2Ø Ø 2Ø Ø 2Ø Ø 0 U461h U461S U461AKi j 15j 60 U462h U462S U462AK U46h U46S U46AK U464h U464S U464AK U U465AK U ire (6 Blades) 600 Vack Ø Ø Ø 0 U661S U661AKl U662S U662AKl U66S U66AKl U664S U664AKl a Complete rating is NEMA, R, 4, 4X, 5 and 12. b Also suitable f NEMA R application by removing drain screw from bottom endwall. c Refer to page 7-2 f additional mot application data. d F switching dc, use two switching poles. e Suitable f NEMA 5 applications with drain screw installed. f Switches with EI suffix are stocked with facty-installed electrical interlocks with one nmally-open and one nmally-closed contact. g Use 60 A enclosure accessies, including electrical interlocks. h No knockouts are provided. i Check series number on switch f crect accessy. See page -14. j U461AK (Series E1) is rated 5 hp@250 Vdc, 10 hp@600 Vdc. k Not suitable f use as service equipment. l One enclosure f,, R 12 applications. UL Listed. Table.12: Fusible Safety Switches F the sht circuit current rating, refer to the table below. eavy uty Safety Switch Type UL Listed Fuse Class UL Listed Sht Circuit Current Ratings Non-Fusible Safety Switches Any brand of circuit breaker fuse not exceeding the ampere rating of the switch may be used in conjunction with an non-fusible safety switch when there is up to 10 ka sht circuit current available (see table below). Above 10 ka hen applied on systems with greater than 10 ka sht circuit current available, the UL Listed sht circuit current rating f Square non-fusible switches is based upon the switch being used in conjunction with fuses Square circuit breakers Mag-Gard mot circuit protects. Table.1: eavy uty Safety Switch Type n o p Non-Fusible Switches Non-Fusible Safety Switches Switch Rating (A) n Fuse Circuit Breaker Typeo -Phase 240 Vac 480 Vac 600 Vac Any brand circuit All breaker Up to 10 ka, K R,T,J.L 200 ka 200 ka 200 ka p 65 ka 5 ka 5 ka FA 14 ka 14 ka 14 ka F 18 ka 18 ka 18 ka 200, J p 65 ka 5 ka 5 ka 200 KA 400 LA 22 ka 22 ka 22 ka 600 MA 200 K 400 L 25 ka 25 ka 25 ka 600 M Applies to, R, 4X stainless, 12 switches. Ampere rating of fuse circuit breaker not to exceed switch ampere rating. All and J circuit breakers are acceptable, but will only suppt the noted Sht Circuit Current Ratings. -6 E1 iscount This document provided by Barr-Thp Electric Co., Inc

7 61SS 6F 61X 60XFA eavy uty Safety Switches Special Applications Class 110 / Refer to Catalog 100CT Grade Stainless Steel NEMA, R, 4, 4X, 5, 12 Type 16 stainless steel enclosure safety switches offer superi crosion resistance to a wider range of chemicals than Type 04 stainless switches. Type 16 better resists chlide and is often used in marine, waste treatment and transptation applications. Use watertight hubs from page -10. Equipment grounding lugs are supplied as standard. (F Type 04 stainless switches see pages -4-6.) Table.14: P 600 Vac, 600 Vdc sepower Ratings Øa Cat. No 480 Vac 600 Vac 600 Vdcb Std. Max. Std. Max. Max. Fusible 0 61SS / SS SS SS SS SS Non-Fusible 0 U61SS U62SS U6SS U64SS U65SS U66SS Fiberglass Reinfced Polyester Enclosures NEMA 4X Fiberglass reinfced polyester enclosures are watertight, crosion resistant, and impervious to windblown dust, rain, and splashing liquid. The molded fiberglass is extremely stable in a wide range of operating temperatures and can withstand heavy impact. Switches are furnished with hubs (page -14) and equipment grounding lugs. UL Listed. Table.15: P 600 Vac, 600 Vdc Electrical Interlock Kits sepower Ratings Øa Class R Fuse Kits Field-Installed c 480 Vac 600 Vac 600 Vdcb 1 NO/1 NC Contact 2 NO/2 NC Contacts Std. Max. Std. Max. Max. Fusible 0 61F RFK TC TC / F RFK TC TC F RFK TC TC Fd RK R8 9999R Non-Fusible 0 U61F TC TC U62F TC TC U6F TC TC U64Fd R8 9999R Krydon Enclosures NEMA 4X Krydon enclosures are compression molded of fiberglass reinfced polyester, specially fmulated to withstand attack from almost any crosive atmosphere found in the toughest industrial application. Switches are furnished with hubs (page -14) and equipment grounding lugs. UL Listed. Table.16: P, 600 Vac, 600 Vdc Electrical Interlock Kits sepower Ratings Øa Class R Fuse Kits Field-Installed c 480 Vac 600 Vac 600 Vdcb 1 NO/1 NC Contact 2 NO/2 NC Contacts Std. Max. Std. Max. Max. Fusible 0 61X RFK TC TC / X RFK TC TC X RFK TC TC Non-Fusible 0 U61X TC TC U62X TC TC U6X TC TC NEMA 7 and 9 An enclosed automatic molded case switch f use in ivisions 1 and 2 of the following: Class I, Groups C and ; Class II, Groups E, F and G; Class III, azardous Locations as defined in NEC Article 500. Furnished with threaded conduit openings in both top and bottom endwall (page -14). Suitable f use as service equipment and listed as Raintight f outdo applications. UL Listed, and CSA Certified. Equipment grounding lugs supplied as standard. Table.17: P, Non-Fusible, 600 Vac, 250 Vdc Maximum, Sht Circuit Rating 10 ka AIR Enclosed Molded Case Switchdf Solid Neutral Assembly sepower Ratings Ø 240 Vac 480 Vac 600 Vacb 60 60XFA SNA XFA SNA XFA SNA XFA SNA XJG SNA XJGAAe SNA a Std. Using fast acting one time fuses. Max. Using dual element time delay fuses. b F switching dc use two switching poles. c Electrical interlock not available. F auxiliary switches, refer to page 7-4 f catalog number suffix and price adder (e.g. 60XFA1212). d Includes PKB1, breather and drain kit, required f rainproof application NEMA 7 only. e Includes auxiliary contacts. f F available options, contact customer service pri to placing an der. E1 iscount This document provided by Barr-Thp Electric Co., Inc

8 UL508 Mot isconnect Switches M Mot isconnect Switches Class 110 / Refer to Catalog 100CT0701 The M mot disconnect switch is listed UL508 Suitable F Mot Control (UL File E164864). It is in a compact NEMA 4X enclosure suitable f use in NEMA Type 1,, R, 4, 4X and 12 applications. The M's key benefits are an extremely small footprint, a me economically efficient NEMA 4X solution and a handle interlock preventing cover removal when the switch is in the ON position. Table.18: a b c M Mot isconnect Switch Non Metallic,, R, 4, 4X and 12 Enclosureabc Maximum se Power Ratings Three Phase Vac eight (in.) idth (in.) epth (in.) 0 M04X $ MC604X $ See table 8.9 f accessies. Complies with OSA lockout/tagout requirements accepts up to three 8 mm padlocks. Suitable f, R, 4, 4X and 12 enclosure applications. Table.19: M Mot isconnect Accessies escription MSAN20 2 Nmally open auxiliary contact module $ MSAN11 1 nmally open and 1 nmally closed auxiliary contact module $ MS0P 0 Amp Add on power pole $ 5.00 M Mot isconnect Switches -8 E1 iscount This document provided by Barr-Thp Electric Co., Inc

9 eavy uty Safety Switches Receptacle Switches Class 110 / Refer to Catalog 100CT0701 Interlocked Receptacle Switches Interlocked Receptacle Switches are furnished with a facty-installed three-phase four-wire Appleton Powertite, Crouse-inds Style 2 Arktite, ubbellock receptacle. The fourth wire is connected to the switch equipment grounding terminal and is not a neutral termination. Interlocking linkage between the receptacle and switch mechanism prevents insertion removal of the plug while the switch is in the ON position insertion of any plug other than specified. Grounding lugs are included. Appleton Powertite Receptacle evices are UL Listed and CSA Certified, suitable f use as service equipment. Receptacles are epoxy powder coated over copper-free cast aluminum and NEMA, R, 4, 4X and 12 rated. Appleton receptacles are UL Classified f use with the Crouse-inds plugs listed below. Sht circuit rating: 10 ka when used in conjunction with Class K fuses; 200 ka when used in conjunction with Class R J fuses. 62AA Interlocked Receptacle Switch with Appleton Powertite Receptacle 62AC Interlocked Receptacle Switch with Crouse-inds Arktite Receptacle 0 U61A U61SA U61AA ACP04BC U62A U62SA U62AA ACP604BC U6A U6SA U6AA ACP104C a Receptacle UL Listed f use with Appleton ACP CP plugs; UL Classified f use with Crouse-inds APJ Arktite plugs listed on this page. b Std. Using fast acting one time fuses. Max. Using dual element time delay fuses. c F switching dc, use two switching poles. Crouse-inds Arktite Receptacle UL Listed, suitable f use as service equipment. Sht circuit ratings: 10 ka when used in conjunction with Class K fuses; 200 ka when used in conjunction with Class R J fuses. 0 U61C U61SC U61AC APJ U62C U62SC U62AC APJ U6C U6SC U6AC APJ d Std. Using fast acting one time fuses. Max. Using dual element time delay fuses. ubbellock Receptacle UL Listed, suitable f use as service equipment. Sht circuit rating: 10 ka. Note: The ubbellock receptacle switch utilizes the Square interlocked plug S12781 available only from Square. e f NEMA, R, 4, 4X, 5, Stainless Steel Enclosure sepower Ratings Øb 2, R Use with Plug a 480 Vac 600 Vac 250 Vdcc Std. Max. Std. Max. Std. Max. Fusible P, 600 Vac, 250 Vdc 0 61A SA AA ACP04BC / A SA AA ACP604BC A SA AA ACP104C Non-Fusible P, 600 Vac, 250 Vdc Table.20: NEMA, R, 4, 4X, 5, Stainless Steel Enclosure sepower Ratings Ød 2, R Use with Plug 480 Vac 600 Vac Std. Max. Std. Max. Fusible P, 600 Vac Maximum 0 61C SC AC APJ / C SC AC APJ C SC AC APJ Non-Fusible P, 600 Vac Maximum Table.21: 2 Use with Plug sepower Ratings Øe 480 Vac 600 Vac Std. Max. Std. Max. Fusible P, 600 Vac Maximum A S12781f Non-Fusible P, 600 Vac Maximum 60 U U62A S12781f Std. Using fast acting one time fuses. Max. Using dual element time delay fuses. ubbell plug is furnished with a Kellems grip f 1-1/2 in. to 1-21/64 in. cable diameter. Accessies pages -10 through A Interlocked Receptacle Switch with ubbell ubbellock Receptacle E1 iscount This document provided by Barr-Thp Electric Co., Inc

10 eavy uty Safety Switches Accessies Class 110 / Refer to Catalog 100CT0701 RB ub Rainproof Bolt-On ubs f use on NEMA R Enclosure Electrical Interlock Kits Electrical interlocks f heavy duty A safety switches are available facty-installed in kit fm f field installation. Each kit contains instructions f proper field mounting. A pivot arm operates from switch mechanism, breaking the control circuit befe the main switch blades break. Switches with electrical interlocks installed are UL Listed. F facty-installed electrical interlocks add EI (f one contact) EI2 (f two contacts) suffix to catalog number. See Supplemental igest page 2-4 f electrical interlock contact ratings. Table.22: Electrical Interlock Kit a Switch s Series Number Rating (See pages -1, -14) 0 F1, F5 F7 EIK01c d EIK02c d F EIK1 EIK F1-F EIK1 F5 F7 (600 V) EIK F4 EIK01e F5 F6 (240 V) EIK02e F2 F7 EIK1 EIK E1 E4 EIK40601 EIK a See page -7 f electrical interlocks on NEMA 4X fiberglass reinfced polyester and Krydon. b Electrical interlock kit catalog numbers with 1 suffix indicates one nmally open and one nmally closed contact; 2 indicates two nmally open and two nmally closed contacts. Kits are UL Listed. c U461AK uses EK061 EK062. d The following Series F5 F7 devices use EIK-1, 2: 612, 612A, 612AK, 612RB, 461, 461S, 461AK, U461, U461S, U661S, U661AK, 61AA, 61AC, U61AA and U61AC. e 62A, U62A, 62C, 62AA, U62AA, 62AC, U62AC, and 2212AK use EIK1 EIK2 electric interlock. f Single-pole single-throw interlock kits are rated 1/2 110 and 220 Vac. Class R Fuse Kits hen installed, this kit rejects all but Class R fuses. Kits are available f field installation. F facty installation, add CLR suffix to catalog number. Table.2: 0 F5 F7 RFK0Lg F1, F2, F RFK F4 F7 RFK F2 F7 RFK F5 F6 RK E RK g 221-2AK uses RFK06 Class R fuse kit. Conduit Size / /4 1-1/ /2-1/2 4 Closing Cap ub B075 B100 B125 B150 B200 B250 B00 B50 B400 BCAP Each (E1A) Note: NEMA R rainproof enclosures with ending in RB have a bolt-on closing cap facty-installed. Order bolt-on hubs separately from table above. F me details see page 1-1. ubs through size can be directly installed on RB devices. evices requiring threeinch larger hubs must have holes cut in the field. Gaskets are provided on three-inch and larger hubs. Note: All hubs are UL Listed f indo and rainproof applications and suitable f use with conduit having ANSI standard taper pipe thread. atertight ubs f use on NEMA 4, 4X and 5 Stainless Steel and 2 Enclosures Conduit Trade Size 1/2 / /4 1-1/ /2-1/2 4 Standard-Zinc ub Zinc Each Chrome Plated ub 050CP 075CP 100CP 125CP 150CP 200CP Chrome Plated Each Electrical Interlock Kit b Facty-Installed Class R Fuse Kits 240 V (one kit per P switch) Series Number (See pages -1, -14) Class R Fuse Kit Facty-Installed Table.24: h i Internal Barrier Kits Internal Barrier Kits provide an additional barrier that helps prevent accidental contact with live parts. Field-installed transparent barriers do not restrict visual inspection of the switch. Barriers provide IEC529 IP2X finger safe protection when do of enclosed disconnect switch is open. Convenient do allows use of test probes without accessing fuses and replacement of fuses without removing barrier. Barrier can also be used with the skirt kit to enclose a panel mounted Type 9422 disconnect. SS0 Interi Barrier f 0 A 240 / 600 Vac 0 A Safety Switchj 240 Vac 60 A NA 150. Interi Barrier f 60 A 600 Vac 0 A SS06 Safety Switch, 0 60 A 9422 Switch 600 Vac 60 A 600 Vac 60 A 165. Interi Barrier f 100 A SS10 Safety Switch 240 / 600 Vac 100 A 600 Vac 100 A A 9422 Switch SS20 Interi Barrier f 200 A Safety Switch 240 / 600 Vac 200 A NA 225. Skirt Kit to Enclose Vac 0 A SS006SK 60 A 9422 Switch (requires SS06) NA 600 Vac 60 A 225. Skirt Kit to Enclose 100 A SS10SK 9422 Switch NA 600 Vac 100 A 255. (requires SS10) j Requires arc shield on 240 V switches be changed to 600 V arc suppress. Fuse Puller Kits Kit consists of three fuse pullers as required f a -pole fusible 240 V 600 V heavy duty switch. Kits can be installed in switches manufactured after February, Fuse pullers supplied as standard equipment on 2, 12K, NEMA 4, 4X, 5 stainless steel, NEMA 4X fiberglass reinfced polyester and KRYON switches through 100 A. k l Class R Fuse Kits 600 V (one kit per P switch) Series Number (See pages -1, -14) Class R Fuse Kit Facty-Installed 0h F1, F5 F7 RFK0i h F RFK h F1 F7 RFK06 i h F2 F7 RFK F5 F6 RK E2 E4 RK See page -7 f Class R Fuse Kits in NEMA 4X Fiberglass Reinfced Polyester and Krydon switches. The following Series F5 F7 devices use RFK06: 612, 612A, 612AK, 612RB, 461, 461S, 461AK, 61AA and 61AC. escription Safety Switch Application (F Series Only) 9422 Type T isconnect Application Series Number Fuse Puller Kit l F1, F5 F7 F F1, F2, F, F5 F7 (600 V) F4 l, F5 F7 (240 V) FPK0 k FPK0610 FPK0610 FPK0 l F2 F7 FPK A 4- and 6-pole, 61-2 and 61-2RB Series F5 use FPK A, 62C, 62AA, 62AC, 62 and 62A use FPK0610 fuse puller kit. -10 E1 E1A iscount This document provided by Barr-Thp Electric Co., Inc

11 eavy uty Safety Switches Neutral Assemblies Field-Installed Neutral Assemblies f Fusible and Non-Fusible 240 and 600 Volt Safety Switches Standard Series Number Terminal ata Neutral Kit (See pages -1, -14) Optional Copper Only Terminal ata Neutral Kit 0 F1, F5 F6 SN0a () 2 Max. Al/Cu 8.00 SN0Ca () 6 Max. Cu F1 F, (2) 1/0 Max. Al/Cu (2) 1/0 Max. Cu SN SN0610C F5 F6 (600 V) (2) 6 Max. Al/Cu (2) 6 Max. Cu F4, F5 F6 (240 V) SN0a () 2 Max. Al/Cu 8.00 SN0Ca () 6 Max. Cu F2 F6 SN0610 (2) 1/0 Max. Al/Cu (2) 1/0 Max. Cu SN0610C (2) 6 Max. Al/Cu (2) 6 Max. Cu b F5 F6 SN20A (2) 250 Max. Al/Cu (1) 1/0 Max. Al/Cu SN20C (2) 250 Max. Cu (1) 1/0 Max. Cu (2) 600 Max. Cu 400 and E1 E4 600SN (4) 750 Max. Al/Cu SNC (2) 50 Max. Cu 600 (1) 00 Max. Al/Cu (1) 250 Max. Cu E2 E4 800SNE4 (6) 750 Max. Al/Cu (2) 50 Max. Al/Cu 1200 E2 E4 1200SNE4 (8) 750 Max. Al/Cu (2) 50 Max. Al/Cu Note: Neutrals cannot be installed in 4P, 6P, 200 A NEMA 4X fiberglass reinfced polyester safety switches. a The following Series F5 F6 devices use SN0610(C): -61-2, -61-2RB, -61-2A and -61-2AK. b F 200% neutral, der (2) neutral kits and (1) SN20NI neutral jumper kit. (2) 50 Max. Al/Cu. suffix GL to standard (Example: 61GL). Price = Switch + Kit Price. Equipment Grounding Kitsg Equipment grounding kits are field-installed and UL Listed in A heavy duty switches. F facty installation of equipment grounding kit, add Equipment Grounding Kits Field- Facty-Installed Equipment Grounding Kits 240 and 600 V Accessies and Special Features Class 110 / Refer to Catalog 100CT Series Number (See pages -1, -14) Standard Terminal ata Optional Copper Only Terminal ata 0 F1, F5 F7 GTK0c (2) 12 Cu (2) 10 Al (1) 4 Max. Al/Cu GTK0Cc (1) 6 Max. Cu d F1 Fd, F5 F7 (600 V) GTK0610d (2) 1/0 Max. Al/Cu GTK0610Cd (2) 4 Max. Cu F4, F5 F6 (240 V) GTK0 (2) 12 Cu (2) 10 Al (1) 4 Max. Al/Cu GTK0C (1) 6 Max. Cu F2 F7 GTK0610 (2) 1/0 Max. Al/Cu GTK0610C (2) 4 Max. Cu F5 F7 PKOGTA2 (2) 2/0 Max. Al/Cu PKOGTC2 (2) 4 Max. Cu and 600 E2 E4 PKOGTA2e (2) 2/0 Max. Al/Cu PKOGTC (2 Required) (4) 1/0 Max. Cu f 800 E2 E4 PKOGTA7 (4) 50 Max. Al/Cu f 1200 E2 E4 PKOGTA8 (8) 50 Max. Al/Cu 20.00f c The following Series F5 F6 devices use GTK0610(C): and -61-2RB. d 4- and 6-pole 0 A F Series. e Two required if grounding conducts are run in parallel. f PE1A iscount g Equipment Ground Kits are facty-installed standard in A series F NEMA 4-4X-5 (stainless) and 12. Equipment Ground Kits are standard on all NEMA Types, Series F A 4 and 6 pole switches. Table.25: Square Gray Paint escription 16 oz. Aerosol Paint Can, Square Gray Paint PK49SP 9.00 ea. Note: Shipped in quantities of 6. Special Paint UL Listed heavy duty switches are available painted with special safety cols. To der safety coled switches add suffixes as noted in Table.26 to the standard switch commercial reference number. All cols comply with OSA Standard and ANSI Specification Z55.1 f marking physical hazards. Table.26: Safety Col Black Red Orange Yellow Green Blue Purple Gray hite Safety Cols Suffix SP0 SP2 SP SP4 SP5 SP6 SP7 SP8 SP9 A minimum quantity of 10 is required. Not available f NEMA Type 7/9 stainless steel products. Price Adder Each Switch Quantity 0 A 60 A 100 A 200 A 400 A 600 A 800 A 1200 A Lock-Off Guard Kits Available facty- field-installed the lock-off guard wks by covering the lockout/tagout opening whenever the switch is in the ON position. This prevents a padlock from being inadvertantly inserted into the switch lockplate. The device is designed to help prevent accidental misapplication of a lockout device. These kits are marked curus (UL Component Recognized) f field facty installation. 0 A 60 A 240 V Kit Cat. No. Field-Installed Facty- Installed LOGK A 600 V LOGK and 200 A h F facty installation, add suffix LOG to the switch catalog number. E1 PE1A iscount This document provided by Barr-Thp Electric Co., Inc

12 eavy uty Safety Switches Key Interlock Systems Facty-installed only on heavy duty safety switches and double throw safety switches. Interlocks are used to prevent the authized operat from making an unauthized operation. Not available on hazardous location devices (NEMA 7/9) fiberglass reinfced polyester (NEMA 4X). The key interlock system is a simple and easy method of applying individual key interlock units and assemblies to the above equipment so as to require operation in a predetermined sequence. UL Listed. Quoting: Contact Schneider Electric f catalog number, availability, and pricing pri to quoting a job. etailed infmation is required befe an der can be processed. Please see Supplemental igest Section 2 f further infmation. Use these suffixes on switch catalog numbers: KI = 1 lock per switch KI2 = 1 lock with 2 cylinders (2 keys) per switch KIKI = 2 separate locks per switch Table.27: a Price Adder Per Lock a Switch Type A eavy uty A ouble Throw Prices do not apply when me than three devices are interlocked, as these schemes nmally require me than one key assembly per device. Lock-On Provisions Lock-off provisions are standard on all heavy duty safety switches. Provision f one 8 -inch hasp padlock is available facty-installed on, R, 4-4X-5 stainless steel and 12 switches. This modification will allow the switch to be locked in the ON position. UL Listed. Table.28: To der, add suffix SPLO to standard catalog number. Example: 64-SPLO Price Adder Per Each Switch Safety Switch Rating A Cover Viewing indow Optional cover viewing window is positioned over the blades to allow visual verification of ON-OFF status. Available on 0 through 1200 A heavy duty switches, all NEMA Types. (Not available on NEMA 4X fiberglass reinfced polyester, Krydon enclosures, NEMA 7 and 9 devices.) Facty-installed only: add V suffix to the See table below f price adder. Table.29: Price Adder Per Switch UL Listed 2- and -Pole 4- and 6-Pole A A Switch Lubricant Field maintenance lubricant is available f servicing blade and jaw components in switches 600 V and below. Catalog number SLUB (list price $24.14) consists of one tube of BG20 igh Perfmance Synthetic Grease manufactured by ow Cning, a material safety data sheet, and re-lubrication infmation. SLUB is available in warehouse stock, shipped individually on in multiples of 12 units per carton. BG20 grease by ow Cning is a high-perfmance synthetic grease which is biodegradable and has an operating temperature range from -50 F (-45 C) to 60 F (180 C). This temperature range exceeds nmal operating conditions f switches as defined by NEMA. This grease has undergone extensive testing as a lubricant f maintaining blade and jaw areas in switches. o not substitute any other lubricants. Accessies and Special Features Class 110 / Refer to Catalog 100CT0701 Copper Only Lug Kits eavy duty safety switches are supplied standard with Al lugs, which accept both Cu and Al wires. F field installation of copper-only lug kits, der kits below. F facty installation of copper only lugs, add suffix SLC to standard Note: 2, 12K and stainless steel switches with facty-installed lugs bear the UL Marine Listed manifest f use on vessels over 65 feet long. 2, 12K and stainless steel switches using field-installed copper only lug kits are UL Marine Listed, but do not bear the marine manifest. 0 CL006F CL006F CL10F CL20F CL40F CL60F bone kit includes all phase line/load lugs f a - pole switch. ouble Lug Kits 200 A heavy duty F-series switches are supplied standard with lugs listed on page -1 (one wire per phase). F lugs that accept two wires per phase and neutral, der the following kit: 200 AL20TF (2) 6 00 Cu/Al (2) Cu/Al c Not UL Listed. d Kit contains lugs. F double lugs f line and load, der 2 kits. Table.1: 800 and 1200 A Compression Lug Kits Field- Installed (See page -1 f A Switches) Series E4 800 and 1200 A safety switches are equipped as standard with mechanical lugs. Alternate compression lug kits are available f field installation and are UL Listed. Each kit consists of VCEL Versa-Crimp Compression Lugs and lug landing connects capable of converting line and load side of one switch pole neutral. Order one field-installed kit per pole neutral per table below. Example: Three-pole three-wire requires three kits; three-pole, four-wire requires four kits. Note: 800 8LKE LKE F terminal lug data, refer to table below. Table.2: Facty-Installed Series E4 800 and 1200 A safety switches are available with factyinstalled VCEL Versa-Crimp compression lug kits (above). F facty installation, add suffix LK to standard (Example: 67LK) and use price adder from table below based on system type. Note: Lug Kitc Kit d Table.0: Kits ire size (pp -1) Lug Kit b Lug wire range per phase and neutral Lug Kit Kit Facty-Installed Adder per Switch Switch wire range per phase and neutral Per Pole Neutral System Facty-Installed Adder Per Switch 2 ire ire ire ire ire ire F terminal Lug data refer to table below. Table.: Al/Cu to Cu Only Terminal Lug ata 800 and 1200 A Compression Lugs Conducts Per Phase Compression Lug (VCEL ) ire Range () kcmil (Al) and () 500 kcmil (Cu) (4) kcmil (Al) and (4) 500 kcmil (Cu) -12 E1 E5 iscount This document provided by Barr-Thp Electric Co., Inc

13 eavy uty Safety Switches NEMA Type 1 and R imensions, Lug ata Class 110 / Refer to Catalog 100CT0701 Table.4: Terminal Lug ata (, R, 4, 4X, 5, 7, 9, 12)a / Typical / Typical NEMA R Rating (A) Conducts Per Phase and Neutral ire Range ire Bending Space Per NEC Table 12.6 Lug ire Range Optional Versa-Crimp Compression Lug Field-Installedb (Al) 14 6 (Cu) 12 2 (Al) 0c (Cu) solid (Cu) stranded 14 2 (Cu) 60d 1 14 (Al) 14 (Cu) 12 2 (Al) 14 2 (Cu) /0 (Al) 14 1/0 (Cu) 12 1/0 (Al) 14 1/0 (Cu) VCEL02114S1 200e (Al/Cu) 6 00 (Al/Cu) VCEL VCEL /0 750 (Al/Cu)f 1/0 750 (Al/Cu) 400 and VCEL005161g 2 1/0 00 (Al/Cu) 1/0 00 (Al/Cu) and VCEL /0 500 (Al/Cu) /0 500 (Al/Cu) VCEL /0 750 (Al/Cu) /0 750 (Al/Cu) 8LKE2h /0 750 (Al/Cu) /0 750 (Al/Cu) 12LKE2 h a A switches suitable f 60 C 75 C conducts A switches suitable f 75 o C conducts. b F and R only. c U461AK 14 6 AG (Cu). d 60XFA 14 6 AG (Cu). e 225XKA 4 AG 00 kcmil (Cu). f Max. wire range is (1) 600 kcmil (2) 00 kcmil Al/Cu on NEMA 4X Stainless and 2. g Order two PK516KN mounting kits when installing VCEL lugs. Only one kit is required on 2-Pole switches. h See page -12, 800 and 1200 A compression lug kits f additional infmation. Approximate imensions Approximate imensions / / Series Series in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm 221N F , N F NRB F RB, NRB F N F , N E NRB F R, NR E N F , N E NRB F NR, R E N F , N E NRB F NR, R E , N E , N E NR, R E NR, R E , N E F NR, R E F , N E F NR, R E F , N E E NR, R E E E U265 E R E U265R E E U266 E R E U266R E E U267 E R E U267R E E U268 E R E U268R E N F U61 F NRB F U61RB F N F U61A F NRB F U61C F N F U62 F NRB F U62RB F N F U62A F NRB F U62C F , N E U62 F R, NR E U6 F , N E U6RB F R, NR E U6A F , N E U6C F R, NR E U64 F , N E U64RB F R, NR E U65 E , N F U65R E F U66 E NRB, RB F U66R E A F U67 E C F U67R E , N F U68 E NRB, RB F U68R E A F U461 F C F U462 F F U46 F , N F U464 F NRB, RB F U465 E A F U466 E C F This document provided by Barr-Thp Electric Co., Inc

14 eavy uty Safety Switches NEMA Type 4, 4X, 5, 7, 9 and 12 / Typical NEMA 4X Typical NEMA 4, 4X, 5, 12, Fiberglass Reinfced Polyester and Krydon 12K (Stainless has flat front) Table.5: Optional Copper Only Lug Kits (See page -12 f pricing. See page -1 f terminal lug data f the series switches listed in the dimension table below.) Optional Lug Kit a Lug ire Range Per Phase 0 60 CL006F (1) 14 8 Cu solid 14 4 Cu strand 100 CL10F (1) 14 8 Cu solid 14 1/0 Cu strand 200 CL20F (1) Cu 400 CL40F (1) Cu plus (1) Cu 600 CL60F (2) 4 50 Cu a One kit includes all phase line/load lugs f a -pole switch. Table.6: Conduit Provisions (NEMA 4X Fiberglass Reinfced Polyester and Krydon, NEMA 7 and 9.) b c Top and Bottom Endwall NEMA 4X Fiberglass Reinfced Polyester and Krydonb NEMA 7 and 9c 0 /4 in /4 in. /4 in in. 1-1/4 in /2 in. 2-1/2 in. ubs and hub drilling templates are provided f field-installation. Threaded conduit opening. Approximate imensions / Series in. mm in. mm in. mm in. mm 60XFA E XFA E AK, A F S F AK F AK, A F S F AK, A F S F A,AK F S F AK, S E NAK, NS E XJG C AK, S E NAK, NS E AK, NAK E AK, NAK E AK, S E AK, A, S E AK, NAK E AK, NAK E AK, A F S F AK, A F S F AK, A F S F A,AK F S F AK, S E NAK, NS E AK, S E NAK, NS E AK, NAK E AK, NAK E AA F AC F AK, A F S F SA F SC F F F X F SS F AK, A F AA F AC F A F AK, A F S F NEMA Types 4, 4X, 5, 7, 9, 12 and 12K imensions Typical NEMA 7, 9 Class 110 / Refer to Catalog 100CT0701 Series Approximate imensions / in. mm in. mm in. mm in. mm 62SA F SC F F F X F SS F AA F AC F AK, A F S F SA F SC F F F X F SS F A,AK F S,NS F NA,NAK F F E SS F AK, S, SS E NAK, NS E AK, S E NAK, NS, SS E AK, NAK E AK, NAK E AK F S F AK F S F AK F S F AK F S F AK E AK F S F AK F S F U265AK, S E U266AK, S E U267AK E U268AK E U61AA F U61AC F U61AK, A F U61S F U61SA F U61SC F U61F F U61X F U61SS F U62AA F U62AC F U62A F U62AK, A F U62S F U62SA F U62SC F U62F F U62X F U62SS F U6AA F U6AC F U6AK, A F U6S F U6SA F U6SC F U6F F U6X F U6SS F U64A,AK F U64F E U64S F U64SS F U65AK, S, SS E U66AK, S, SS E U67AK E U68AK E U461AK E U461S F U462AK F U462S F U46AK F U46S F U464AK F U464S F U465AK E U661AK F U661S F U662AK F U662S F U66AK F U66S F U664AK F U664S F This document provided by Barr-Thp Electric Co., Inc

15 ouble Throw Safety Switches A Types T, TU (Series F) Fusible and Non-Fusible Class 140 / Refer to Catalog 100CT0701 Fusible (T) and non-fusible (TU) switches available Manually-operated switch suitable f use in accdance with article 702 of the NEC, ANSI/NFPA 70 Standards: UL 98, NEMA KS1, CSA, and NOM Modular design switch handle, lock-plate, switch mechanism; line and load bases are field replaceable UL Listed sht circuit current ratings up to 200 ka (using Class R, J, T fuses see table f rating) make/break rated Meets NEMA hp ratings ual cover interlock May be padlocked ON (I) OFF (O) Lock-off accepts up to three padlocks Side-opening do Quick make / quick break mechanism Meets NEMA requirements as heavy duty switch Field-installed electrical interlock kits Field-installed neutral assembly kits (2P and P switches) UL Listed as suitable f use as service equipment Supplied as standard f switching one load between two power sources, and may be field-converted to switch on power source between two loads. 0 (Series T4), A Types 82,000 and 200 A TU (Series E, A) Non-fusible esigned f manual transfer of loads from one supply to another UL Listed switches are suitable f use in accdance with Article 702 of the National Electrical Code, ANSI / NFPA 70 All 82,000 and TU double throw switches are continuous duty rated f their nameplate ampere rating The 82,000 and TU (Series E, A) switches are load make/break rated UL Listed as suitable f use as service equipment sepower rated only as footnoted. Field-Installed Accessies: Neutral Electrical Interlock Grounding Terminals A T, TU (Series F) 82,000 This document provided by Barr-Thp Electric Co., Inc

Section 3. Table of Contents. Safety Switches. General Duty. Light Duty. Heavy Duty. Double Throw 3-1

Section 3. Table of Contents. Safety Switches. General Duty. Light Duty. Heavy Duty. Double Throw 3-1 Table of Contents Section Safety es General uty General uty & Not -2 Application ata and imensions - Standards: UL 98 Enclosed and ead Front es. UL Listed under File E2875. NEMA Standards Publication KS1.

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Catalog Number Description

Catalog Number Description Catalog Number escription Enclosed Safety Switches Number Segment Character escription 2 N RB L=Light duty =General duty Fusible =eavy duty Type of Switch T=ouble throw U=General duty Non-Fusible U=eavy

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................

More information

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D 2 N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Catalog Number Description

Catalog Number Description Description Enclosed Safety Switches Segment Character Description D 2 N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double

More information

Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $

Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $ January 1 Vol. 1, ef. No. [0247] eavy uty, Fusible, - 361FK NEMA 12 Enclosure Industrial ust-tight NEMA 4 Enclosure atertight, Painted Steel Enclosure Corrosion esistant, Stainless Steel 2-Pole 40V AC

More information

Enclosed Safety Switches

Enclosed Safety Switches Enclosed Safety Switches Catalog CT0901 09 Class CONTENTS Description............................................. Page General Duty Safety Switches.............................. Page 4 Heavy Duty Safety

More information

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Selection Guide Contents Descriptions Page General Information Features and Benefits 2-3 Product Illustrations General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Heavy Duty Safety

More information

Safety Alert: Square D Safety Switches

Safety Alert: Square D Safety Switches Safety Alert: Square D Safety Switches Be Sure to Inspect Your Installed Units for Defects Schneider Electric has issued an offer safety alert on the Square D safety switch due to electrical shock hazard

More information

1.1. Switching Devices

1.1. Switching Devices . Switching Devices Six-Pole Motor Circuit Contents Description Page Product Overview......................... V2-T-2 General Duty............................. V2-T-24 Heavy-Duty..............................

More information

General and Heavy Duty Safety Switches Accessories

General and Heavy Duty Safety Switches Accessories eneral and Heavy uty Safety es Accessies Selection HR612 HT63 HN612 lass R use lip Kits All eneral uty and Heavy uty es are field convertible to accept lass R use lip Kits. The kits prevent the installation

More information

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch . Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch Double-Throw, continued Ampere Rating Catalog Number Selection Safety Switch Catalog Number Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA X 30 N/A N/A N/A N/A

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

600V, Non-Fusible, (3-Pole, 3 Phase)

600V, Non-Fusible, (3-Pole, 3 Phase) 0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless

More information

NMC Combination Line Starters and Enclosures

NMC Combination Line Starters and Enclosures NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles Compatible with UL 1686 C1 Pin & Sleeve Devices Safer. Easier. Better. MENNEKES Non-Metallic MSR Switched and Interlocked

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application Bussmann Open and Enclosed Rotary Disconnect Switches Exceptional Breadth and Availability f Your Application 2 Visit us on the web at www.cooperbussmann.com/disconnects Table of Contents Compact Circuit

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable

More information

T CLASS T FUSE BLOCKS

T CLASS T FUSE BLOCKS Ferraz Shawmut Fuse Blocks accommodate fuses up to 600A. Insulators are either of durable, glassfilled polycarbonate (GFPC) or phenolic with verified dielectric strength in excess of 2500V. Ferraz Shawmut

More information

Quik-Spec. Section Contents

Quik-Spec. Section Contents Section Contents Page Quik-Spec Coordination Panel Boards......... 238-239 Quik-Spec Power Module Switches and Panels.. 240-241 Quik-Spec DC Safety Switches.................. 242 Quik-Spec Solar Combiner

More information

Solar Combiner Solutions

Solar Combiner Solutions Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from

More information

Single Socket and Horizontal Metering

Single Socket and Horizontal Metering G nergy onnections Single Socket and orizontal Metering T Approved Single Socket Metering T Approved Application Information G s Single Socket Metering products are designed for residential use. They are

More information

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC) 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC) Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit

More information

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

Instructions for Installation, Operation and Maintenance of: WSRD Interlocked Receptacles 30, 60 & 100 Ampere 331114-1 INSTRUCTION SHEET Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere Read instructions carefully and with full understanding for safe

More information

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. EBR Receptacle Class

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle Features 30-600A, 600VAC and DC ratings UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 15852 Visible blade quick make and break switching action Panel and Flange mounted assemblies

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

Hazardous Duty Applications

Hazardous Duty Applications Hazardous Location Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Applications Russellstoll Hazardous Duty Plugs, Receptacles and Interlocks

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

EPOXY POWDER COATED COPPER FREE ALUMINUM

EPOXY POWDER COATED COPPER FREE ALUMINUM 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AJA510 Alum MTG Unilet Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category Features

More information

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description

More information

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. NEC EBR Receptacle:

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC) 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC) Appleton/Oz Gedney Catalog Number ACP1034CD Manufacturer Appleton/Oz Gedney

More information

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine eavy Industrial/ Marine Benefits builds a variety of benefits into one plug, receptacle and interlock system for your application. Safety Waterproof construction: standard neoprene O ringed interior components

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

Product Guide. NEMA pump controls.

Product Guide. NEMA pump controls. Product Guide NEMA pump controls www.usa.siemens.com/controls Class 87 full voltage pump controller with fusible disconnect switch and standard features Class 87 NEMA full starter pump control panels Product

More information

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles ENR Value Series Dead Front Interlocked Circuit Breaking s Cl. I, Div. & 2, roups B, C, D Cl. II, Div. & 2, roups F, Cl. III, 7BCD, 9F, 2 Dust-Ignitionproof Raintight et Locations ENP Plugs Applications:

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures 30-600 Amperes: TG and TH 800-1200 Amperes: TC Equipment Ground Kits Ampere Rating AWG/kcmil Copper AWG/kcmil Aluminum Standard Package

More information

Type VBII Visible Blade Disconnect Switches

Type VBII Visible Blade Disconnect Switches Type VBII Visible Blade Disconnect es Product Guide Siemens Type VBII visible blade disconnect switches meet either UL98 or UL1741 requirements and can be used in either service entrance or branch circuit

More information

Busway Construction. Bus Bars

Busway Construction. Bus Bars Busway Construction Bus Bars A better understanding of what busway is can be gained by examining its construction. A typical Siemens Sentron busway section has three or four formed aluminum or copper bars

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings.

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings. Ratings Ferraz Shawmut Class H, K and R Fuse Blocks accommodate all Class H, K and R 250 and 600V power fuses. A choice of screw, pressure plate, box and special order stud connectors fit a wide range

More information

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Arktite Heavy Duty Circuit Breaking Plugs and Connectors Arktite Heavy Duty Circuit Breaking Plugs and Connectors 60 A, 600 VAC/250 VDC, 50**-400 hertz Dimensions Page 968 1P Plug Connector Mating APJ Plugs Mating APR Connectors Style 1 Description Cat. # Dia.

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

Transfer switch OTEC and OTECSE open transition

Transfer switch OTEC and OTECSE open transition Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY EDS2274 Pos D.E. Selector Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type SINGLE GANG Contact Configuration 4NO-4NC Number of Circuits

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

ENCLOSED DISCONNECT SWITCHES

ENCLOSED DISCONNECT SWITCHES Ferraz Shawmut Enclosed isconnect es are designed to meet customer s requirements for compact and durable individual disconnecting means. Both fusible and non-fusible versions are available in a variety

More information

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +

More information

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1 Sect_0_Speedfax2007 /26/07 5:05 PM Page -1 SPEEDFAX TM 2007-2008 Safety Switches Contents Safety Switch Guide Form Specifications -2 Feature Comparison - Enclosure Types -4 Catalog Numbering System -5

More information

Solar Combiner Solutions

Solar Combiner Solutions Solar Combiner Solutions Providing combiners and disconnects that offer superior resistance and durability from harsh weather and abusive solar environments Solar Technology Leading the way in Solar Technology

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical

More information

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com AR331 30 Amp Pin & Sleeve Recpt 3-W 3-P 250VDC/600vac Cooper Crouse-Hinds Catalog Number

More information

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install Midwest Electric Products Safety Switches Rugged, reliable and easy to install Midwest Safety Switches Features Midwest Electric Products offers a wide variety of general duty and heavy duty safety switches,

More information

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Enclosed Rotary Switch Product Specification Sheets Table of Contents Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX

More information

Accessories. Accessories. Meter Mounting Equipment

Accessories. Accessories. Meter Mounting Equipment Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight ALPF Factory Sealed Lighting - APPF Power Distribution boards xplosionproof, Dust-Ignitionproof, Watertight NC: Class II, Division 1 and 2, Groups, F, G NA 4, 4X, 7BCD, 9FG Applications Distribution panelboards

More information

Compact Circuit Protector

Compact Circuit Protector Supersedes February 2019 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP2) 2011/65/EU CCP2 switch up to 100 A 200 A CCP2 switch 400 A CCP2 switch Contents Page 30, 60 and 100 amp switches s and

More information

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous 3P Description Page No. Application/Selection 1016, 1017 Interlocked Receptacle with Disconnect Switch WSR 30, 60, 100A Aluminum 1018,

More information

Big performance in a small package

Big performance in a small package Series Fusible & Non-fusible Sprecher + Schuh s series of fused and non-fused disconnect switches comply with service entrance requirements. This family of rod operated switches is suitable for applications

More information

Air Conditioning Disconnects Molded Case Switch

Air Conditioning Disconnects Molded Case Switch Air Conditioning Disconnects Molded Case Switch Catalog 3150CT0401R08/09 2009 Class 3150 QO200TR QO200TRNM CONTENTS Description............................................. Page..........................................

More information

Hubbell Marine Isolation Transformers 15 kva and 25 kva Models

Hubbell Marine Isolation Transformers 15 kva and 25 kva Models Shore Power System 15 kva and 25 kva Models Protects Sensitive Equipment on Board Virtually Eliminates Potential for In-Water Stray Current Can be wired per ABYC E-11 for either a Polarization or Isolation

More information

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! To learn the basic differences between control, load and fusible

More information

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38 Series 7 Motor (to 100A)...2 Series 7 Enclosed (to 100A)...14 Technical Information...18 Dimensions...22 Series 7 (to 315A)...29 Technical Information...36 Dimensions...38 Series 10 Fusible and Non-Fusible...45

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY EDSC210 -Way Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type Contact Configuration Current Rating Voltage Rating Material, Color, and

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes April 2014 UL Class CC, CF (CUBEFuse ), Midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-Pole Class CC, Midget, 10x38mm Description & Specifications....

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

Selection and application guide

Selection and application guide Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Section 4. Safety Switches.

Section 4. Safety Switches. Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG...4-5 eavy Duty, Type T...4-7 eavy Duty Stainless Steel, Type T...4-11 Mill Duty, Type T...4-13 Double Throw Switches, Type TC, TDT...4-15

More information

Big performance in a small package

Big performance in a small package Series usible & Non-fusible 100 400A Suitable as a Service Entrance ing Means TIP! Manual Switching Devices: Control, oad or usible Which is Best or Your Application? Application Data Typical Control Switch

More information

Just the right switch for your application

Just the right switch for your application Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

Compact Circuit Protector

Compact Circuit Protector Technical Data 10801 Supersedes August 018 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP) Contents Page 011/65/EU and specifications.... -3 Catalog numbers.... 4 Conductor information and available

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts 0.- Motor Starters & ontactors Low Voltage Lighting ontactors lectrically eld N January 00 Sheet 18 0 1 7 8 0 1 7 8 0 N-Open (L0-nclosed) 0 mpere 0 mpere Product escription Lighting ontactors are designed

More information

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information