Residential Transition Box. Model RU-1. Specifications. Electrical

Size: px
Start display at page:

Download "Residential Transition Box. Model RU-1. Specifications. Electrical"

Transcription

1

2

3 Residential Transition Box Model RU-1 Model RU-1 transition box provides a quick, simple, and easy transition between a microinverter trunk cable and stranded wire. Using only a single flathead screwdriver, connections can be securely made in the box, eliminating the need for wire nuts and crimp connectors. Specifications Ordering Part Numbers P/N # A Without Cordgrip P/N # A With Cordgrip Electrical Maximum Voltage: 600 V Maximum Current: 55 A Min. Wire Size (Input and Output): #20 AWG Max. Wire Size (Input and Output): #6 AWG Max Operating Temperature: 50 C Connections: (4 Total) - L1, L2, N, Ground Enclosure Material: Fiberglass Reinforced Polyester (FRP) Outer Dimensions (H x W x D): 8 x 8 x 5 Inner Dimensions (H x W x D): 6 x 6 x 4.95 Environmental Rating: NEMA 4X Weight: 3.32 lb Part Diagram UL 1741 Sufficient working space for service loops and bend radii requirements Vynckier Enclosure Systems 271 McCarty Street, Houston, TX P/N: A Highest quality ABB components Input Microinverter Trunk Cable Output Stranded Wire (THWN-2) in Conduit Raised enclosure seal provides maximum weather protection

4

5 Residential Transition Box Model RU-2 Model RU-2 transition box provides a quick, simple, and easy transition point for string inverters and optimizers. Using only a single flathead screwdriver, connections can be securely made in the box, eliminating the need for wire nuts and crimp connectors. Included jumpers enable combinations of 2 strings to be made, eliminating the need for U-joints, Y-connectors, or connector boxes. Specifications Ordering Part Numbers P/N # A Without Cordgrip P/N # A With Cordgrip Electrical Maximum Voltage: 600 V Maximum Current: 55 A (No Jumpers) Maximum Current: 27.5 A (While Using Jumpers) Min. Wire Size (Input and Output): #20 AWG Max. Wire Size (Input and Output): #6 AWG Max Operating Temperature: 50 C Connections: (9 Total) - 4 Positive, 4 Negative, Ground Jumpers: 4 Included Enclosure Material: Fiberglass Reinforced Polyester (FRP) Outer Dimensions (H x W x D): 9.32 x 7.32 x 4.9 Inner Dimensions (H x W x D): 8 x 6 x 4.6 Environmental Rating: NEMA 4X Weight: 4.17 lb Part Diagram UL 1741 Raised enclosure seal provides maximum weather protection Vynckier Enclosure Systems 271 McCarty Street, Houston, TX P/N: A Terminal block jumpers (4 included) provide combination of 2 conductors per jumper Highest quality ABB components Sufficient working space for service loops and bend radii requirements

6

7 Residential Combiner Box Model RF-3 Model RF-3 combiner box that can handle three strings. The box combines and fuses three positive inputs and combines three negative inputs to a single positive output and negative output. Specifications Electrical Maximum Voltage: 600 V Maximum Current: 90 A Maximum Fuse Size: 30A Input Wire Size (Positive and Negative): #14 - #6 AWG Output Wire Size (Positive and Negative): #6 - #2 AWG Max Operating Temperature: 50 C UL 1741 Ordering Part Numbers P/N # A Without Cordgrip P/N # A With Cordgrip Enclosure Material: Fiberglass Reinforced Polyester (FRP) Outer Dimensions (H x W x D): 9.32 x 7.32 x 4.9 Inner Dimensions (H x W x D): 8 x 6 x 4.6 Environmental Rating: NEMA 4X Weight: 5.39 lb Part Diagram Raised enclosure seal provides maximum weather protection Vynckier Enclosure Systems 271 McCarty Street, Houston, TX P/N: A Highest quality ABB components Sufficient working space for service loops and bend radii requirements

8

9 Residential Combiner Box Model RF-4 Model RF-4 combiner box that can handle four strings. The box combines and fuses four positive inputs and combines four negative inputs to a single positive output and negative output. Specifications Ordering Part Numbers Electrical Maximum Voltage: 600 V Maximum Current: 120 A Maximum Fuse Size: 30 A Input Wire Size (Positive and Negative): #14 - #6 AWG Output Wire Size (Positive and Negative): #6 - #2 AWG Max Operating Temperature: 50 C UL 1741 P/N # A Without Cordgrip P/N # A With Cordgrip Enclosure Material: Fiberglass Reinforced Polyester (FRP) Outer Dimensions (H x W x D): x 9.32 x 5.39 Inner Dimensions (H x W x D): 10 x 8 x 5.1 Environmental Rating: NEMA 4X Weight: 6.30 lb Part Diagram Raised enclosure seal provides maximum weather protection Vynckier Enclosure Systems 271 McCarty Street, Houston, TX P/N: A Highest quality ABB components Sufficient working space for service loops and bend radii requirements

10

11 Residential Combiner Box Model RF-6 Model RF-6 combiner box that can handle six strings. The box combines and fuses six positive inputs and combines six negative inputs to a single positive output and negative output. Specifications Electrical Maximum Voltage: 600 V Maximum Current: 125 A Maximum Fuse Size: 25A Input Wire Size (Positive and Negative): #14 - #6 AWG Output Wire Size (Positive and Negative): #6 - #2 AWG Max Operating Temperature: 50 C UL 1741 Ordering Part Numbers P/N # A Without Cordgrip P/N # A With Cordgrip Enclosure Material: Fiberglass Reinforced Polyester (FRP) Outer Dimensions (H x W x D): x 9.32 x 5.39 Inner Dimensions (H x W x D): 10 x 8 x 5.1 Environmental Rating: NEMA 4X Weight: 6.73 lb Part Diagram Raised enclosure seal provides maximum weather protection Vynckier Enclosure Systems 271 McCarty Street, Houston, TX P/N: A Highest quality ABB components Sufficient working space for service loops and bend radii requirements

12

13 Price List - December 2015 Residential Transition and Combiner Boxes Image Part # Model Description UPC Weight (lb) List Price A RU-1 Terminal Box $ A RU-1 Terminal Box with Cordgrip $ A RU-2 Terminal Box $ A RU-2 Terminal Box with Cordgrip $ A RF-3 3-String Combiner Box $ A RF-3 3 String Combiner Box with Cordgrip $ A RF-4 4-String Combiner Box $ A RF-4 4-String Combiner Box with Cordgrip $ A RF-6 6-String Combiner Box $ A RF-6 6-String Combiner Box with Cordgrip $ Cordgrip Information All boxes have optional cordgrips which are factory installed and mounted in the center of Vynckier Enclosure Systems 271 McCarty Street, Houston, TX P/N: the bottom edge of the fiberglass enclosure. Prices subject to change without notice. Orders subject to standard sales terms and conditions. All products are culus Listed for use in US and Canada.

14

15 Fiberglass Disconnect Combiners Series CDF Combiners The Vynckier Series CDF disconnect combiner boxes provide unparalleled protection against the elements in a NEMA 4X enclosure. Utilizing only the highest quality components in a proven Vynckier ARIA enclosure, Soltection combiners enable the fastest installation by providing ample working space and a straightforward, simple layout that is easy for installers. Configuration Standard Specifications culus Listed Padlockable, hinged cover Tinned Copper Busbars UL 1741 Standard 5-Year Limited Warranty Enclosure NEMA 4X Fiberglass Padlockable, hinged cover. Number of Inputs: 6 to 40 Max Operating Temperature: 50 C Dimensions (LxW): 24x16, 28x20, 33x25, 40x32 Electrical Maximum Voltage: 600 or 1000 V Disconnect Sizes (Load Break): 100, 200, 250, 320, 400 A Number of Inputs: 6 to 40 Terminals: Dual Listed for Copper or Aluminum, 90 C Rated Options Blown Fuse Indicating Fuseholders Installed & Pre-Wired Surge Protective Devices (SPD) Installed NEMA 4X Breather/Drain Mechanical Output Lugs / Dual Output Lugs Fuses: Preinstalled, certified 8, 10, 12, 15, 20, 25, 30A Preinstalled harnesses / whips Custom inkjet logos and printing on enclosure Custom pre-drilled holes in enclosure Vynckier Enclosure Systems 271 McCarty Street, Houston, TX Please refer to Series CDF Combiner Part Number Structure for configuration and ordering information. Publication Number:

16 Fiberglass Disconnect Combiners Series CDF Combiner Part Number Structure Disconnect Size Ampacity of the disconnect. 100, 200, 250, 320, 400 A Number of Fuses The number of fuseholders 6 to 40, evens* Installed Fuse Size Ampacity of the installed fuse. 10, 12, 15, 20, 25, 30 A Option Configuration x x x x CDF xxx xx xx xxxx x x Strut For Rack Mounting [N]: None [1]: Strut Mounted Dead Front Secondary Protection [N]: None [1]: Dead Front Output Terminals Quantity and Size SPD Surge Protective Device Drain / Vent Quantity and Size Fuseholders Quantity and Size [1]: Single Lug [2]: Dual Lug [3]: Mechanical Lug [N]: None [1]: Type 2 Surge Protection [N]: None [1]: Drain/Vent Installed [N]: Non-Indicating [1]: Indicating Other Options Factory Installed Whips Custom Inkjet Logos and Printing Custom Pre-Drilled Holes Custom Output Terminals * Standard sizes include 6, 8, 10, 12, 16, 20, 24, 32, 36, and 40 fuse configurations Enclosure Size Determination Disconnect Size Enclosure Size 100A, 200A 250A, 320A, 400A 24x16 Up to 14 Fuseholders 28x20 Up to 28 Fuseholders Up to 18 Fuseholders 33x25 Up to 36 Fuseholders Up to 28 Fuseholders 40x32 Up to 40 Fuseholders Up to 40 Fuseholders Vynckier Enclosure Systems 271 McCarty Street, Houston, TX Publication Number: A

17 Vynckier Enclosure Systems 271 McCarty St Houston, TX Installation Manual Residential Transition / Combiner Boxes Models RU-1, RU-2, RF-3, RF-4, and RF-6 IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS This manual contains important instructions for that shall be followed during installation and maintenance of the combiner and transition boxes. General Notes This manual contains important instructions for all Vynckier Combiner Box models that must be followed. The boxes are designed and tested according to international safety requirements, but as with all electrical and electronic equipment, certain precautions must be observed when installing the disconnect combiner boxes. To reduce the risk of personal injury and to ensure the safe installation and operation of the disconnect combiner boxes, you must carefully read and follow all instructions and warnings in this Installation Manual. Symbols Equipment grounding conductor (EGC) - Environment This product is intended for operation in an environment having a maximum ambient temperature of 50 C. Field Wiring Field wiring terminals are marked with one of the applicable markings: Use Copper Conductors Only when the terminal is rated only for connections to copper wire, Use Aluminum conductors only or Use Aluminum Or Copper-Clad Aluminum Conductors Only when the terminal is rated only for connection to aluminum wires, or Use Copper or Aluminum Conductors or Use Copper, Copper-Clad Aluminum, or Aluminum Conductors when the terminal is rated for connection to copper or aluminum wire. Use of Field-Installed Wire The requirements for Field-Installed Wiring size and type used shall be in accordance with Nation Electrical Code (NEC), Article P/N:

18 The wire size shall be sized based on maximum declared current multiplied by 1.25 correction factor, or adjusted based on ambient temperature per Article (B)(2). The DC input circuits are isolated from the enclosure. System grounding, if required by Section 250 of the National Electrical Code, ANSI/NFPA 70, is the responsibility of the installer. The Photovoltaic System Grounding shall be installed per the requirements of Sections through of the National Electrical Code, ANSI/NFPA 70 and is the responsibility of the installer. Wiring method in accordance with National Electrical Code, ANSI/NFPA 70 wiring methods or Canadian Electrical Code C , Part 1 shall be used for these products. PV String Fuses CAUTION: DISCONNECT SUPPLY BEFORE CHANGING FUSES All Vynckier disconnect combiner boxes are optionally supplied with fuses installed according to the user s predetermined requirements. Ensure that only the fuses of the proper type are used for the rating of the combiner box. Never open a fuse holder while it is under load. Electrical arcing and damage to the fuse holder will occur if a fuse holder is opened under load. Conduit Hubs For conduit hubs, use only UL Listed rain tight, or wet location hubs for entry into the enclosure. Recommended Torque Ratings and Input/Output Wire Size for Models RF-3, RF-4, RF-6 when utilized at the maximum current rating: Component Input (Fuse holder or Negative Input) Output (Power Feed) Terminal Grounding Terminal Block Wire Size (AWG/KCMIL) Wire Type Torque (in-lb) Minimum 14 AWG Cu Conductor 22 Minimum 2 AWG Cu Conductor 50 Minimum 14 AWG Cu conductor 25 In some instances, smaller wire may be used pursuant to the DC Current of the system. It is the responsibility of the installer to determine if a smaller wire size is suitable for the amount of current supplied by the system. P/N:

Disconnect Combiner Box Installation Manual

Disconnect Combiner Box Installation Manual Disconnect Combiner Box Installation Manual SolarBOS, Inc. 310 Stealth Court Livermore CA 94551-9552 925-456-7744 ph. 925-456-7710 fax www.solarbos.com Copyright 2008 SolarBOS, Inc. All rights reserved.

More information

Contactor Combiner Box Installation Manual

Contactor Combiner Box Installation Manual Contactor Combiner Box Installation Manual SolarBOS, Inc. 310 Stealth Court Livermore CA 94551-9552 925-456-7744 ph. 925-456-7710 fax www.solarbos.com Copyright 2008 SolarBOS, Inc. All rights reserved.

More information

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual Combiner Box Installation & Operations Manual SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual TABLE OF CONTENTS Notices and Safety Precautions Pages 1-2 Combiner

More information

Solar Combiner Solutions

Solar Combiner Solutions Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from

More information

Acme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual

Acme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual Acme Conduit Entry String Combiner/Pass-Through FOR PHOTOVOLTAIC INSTALLATION Installation Manual Table of Contents Important Safety Instructions -----------------------------------------------------------------------------------------------------------

More information

Solar Combiner Solutions

Solar Combiner Solutions Solar Combiner Solutions Providing combiners and disconnects that offer superior resistance and durability from harsh weather and abusive solar environments Solar Technology Leading the way in Solar Technology

More information

Combiner Box Installation Manual

Combiner Box Installation Manual Combiner Box Installation Manual SolarBOS, Inc. 310 Stealth Court Livermore CA 94551 925-456-7744 ph. 925-456-7755 fax www.solarbos.com Copyright 2008 SolarBOS, Inc. All rights reserved. All rights reserved.

More information

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE 2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying

More information

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST The following checklist is an outline of the general requirements found in the 2005 National Electrical Code (NEC) Article 690 for Photovoltaic

More information

Microinverters and AC PV modules are becoming. Microinverters and AC PV Modules. Different Beasts. Perspectives on PV.

Microinverters and AC PV modules are becoming. Microinverters and AC PV Modules. Different Beasts. Perspectives on PV. Perspectives on PV Microinverters and AC PV Modules Are Different Beasts by John Wiles Microinverters and AC PV modules are becoming very common in residential and small commercial PV systems. See photos

More information

Quick Connection Panel (QCP) Installation Guide

Quick Connection Panel (QCP) Installation Guide Quick Connection Panel (QCP) Installation Guide DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read this document first. The installer is responsible for compliance with National Electrical

More information

2016 Photovoltaic Solar System Plan Review List

2016 Photovoltaic Solar System Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Photovoltaic Solar System Plan Review List GENERAL PROJECT INFORMATION PLAN CHECK NO DATE JOB ADDRESS CITY ZIP REVIEWED BY PHONE

More information

RSDCOM. Installation and Operation Guide. Commercial Rapid Shutdown Combiner. DOCR Published March 2017 Revision C English

RSDCOM. Installation and Operation Guide. Commercial Rapid Shutdown Combiner. DOCR Published March 2017 Revision C English f Commercial Rapid Shutdown Combiner RSDCOM Installation and Operation Guide Models: RSDCOM M-PC-1Z-4F RSDCOM M-PC-1Z-4F-24V RSDCOM M-PC-1Z-5F RSDCOM M-PC-1Z-5F-24V RSDCOM M-FG-2Z-4F RSDCOM M-FG-2Z-4F-24V

More information

E R C. R E R C ; ; W T E C

E R C. R E R C ; ; W T E C WTEC and its affiliates is an engineering, manufacturing, procurement and construction company dedicated to the alternative energy market. It designs and produces products to move energy from the generation

More information

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

More information

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST The following checklist is an outline of the general requirements found in the 1999 National Electrical Code (NEC) Article 690 for Photovoltaic (PV) Power

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS MNPV10, MNPV12 Combiner Applications: SAVE THESE INSTRUCTIONS PV combiner up to 12 strings using MNPV breakers 1000 VDC Combiner using MNTS touch safe fuse holders and fuses rated for 1000VDC DC load center

More information

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV Medium Voltage Ampacities Single 5kV - 35kV 2 130 145 150 165 2 100 115 115 130 1 155 175 170 190 1 120 135 130 150 1/0 180 200 195 215 1/0 140 155 150 170 2/0 205 225 225 255 2/0 160 175 175 200 3/0 240

More information

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5 Combiner Manual i ii Combiner Manual Combiner Manual Copyright 2004 SMA America, Inc. All rights reserved. All rights reserved. No part of this document may be reproduced, stored in a retrieval system,

More information

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254. 3 Loadbreak Elbows 200 Amp 5-15 kv Industrial pg. 252 Loadbreak Elbows 200 Amp 25 kv Industrial pg. 254 Loadbreak Elbows 200 Amp Industrial pg. 255 Loadbreak Elbows Accessories 3 Loadbreak Elbows 3M 200

More information

Solar Photovoltaic Power. Overarching Objectives. How many questions? 9/16/2012. From plan review to Final Inspection

Solar Photovoltaic Power. Overarching Objectives. How many questions? 9/16/2012. From plan review to Final Inspection Solar Photovoltaic Power From plan review to Final Inspection Overarching Objectives A understandable and predictable process for both the Installer and the Inspector. The installation of safe, efficient,

More information

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM Self-Regulating Heating Cable Installation Guide Tinned Copper Braid UV Resistant Polyolefin Outer Jacket 16 AWG Bus Wire Polyolefin Inner

More information

Grounding Systems. Equipment Grounding & Grounded Conductors

Grounding Systems. Equipment Grounding & Grounded Conductors Grounding Systems Equipment Grounding & Grounded Conductors Definitions A Grounded or Earthed system is one that is connected to the earth Grounded Conductor is a conductor that normally carries current

More information

RAPID SHUTDOWN COMBINER

RAPID SHUTDOWN COMBINER RAPID SHUTDOWN COMBINER Installation and Operation Guide Revision B 2017, Yaskawa Solectria Solar IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 1. General Safety Information This manual contains

More information

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems not exceeding a total combined system ac inverter output rating of 10kW on the roof of a one- or two-family dwelling or

More information

Product manual Rapid Shutdown (RSD) system for residential and small commercial

Product manual Rapid Shutdown (RSD) system for residential and small commercial ABB solar inverters Product manual Rapid Shutdown (RSD) system for residential and small commercial OFF ON List of related manuals Rapid Shutdown manuals & guides Rapid Shutdown (RSD) system for residential

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6 Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6 Installation Guide SBCBTLUS-IUS094510 IMUS-SBCBTLUS Version 1.0 US SMA America, LLC Legal Restrictions Copyright 2010 SMA America, LLC. All rights

More information

CENTRE FEED UNIT UP TO 4000A. Safety

CENTRE FEED UNIT UP TO 4000A. Safety CENTRE FEED UNIT UP TO 000A Safety Centre feed unit New TCC section busbar: Connection options with CRITO PowerClip and CRITO ProfiClip, and terminal studs (screw in c-slot). 1-pole, side busbar support

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

CRITO Connection technology. Double and triple T and TCC section busbars

CRITO Connection technology. Double and triple T and TCC section busbars Centre feed unit 5 Centre feed unit Centre feed unit 5 Centre feed unit up to 4000 A combines the advantages of high short-circuit capacity, drill-free mounting, brace terminal technology and clearly structured

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS MNPV12 & 16 Combiner Instructions Applications: SAVE THESE INSTRUCTIONS PV combiner up to 16 strings using MNPV breakers rated for 150VDC. 120 amps total output PV combiner up to 12 strings using 600VDC

More information

E 90 range of fuse disconnectors and fuseholders Uncompromising performance

E 90 range of fuse disconnectors and fuseholders Uncompromising performance E 90 range of fuse disconnectors and fuseholders Uncompromising performance Designing simplicity ABB competence serving the most demanding customers Suitability for disconnection and switching, effective

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

VITALink Taped Splice Pigtail Crimp

VITALink Taped Splice Pigtail Crimp A Marmon Wire & Cable Berkshire Hathaway Company VITALink Taped Splice Pigtail Crimp 1 Hour Fire-Rated Splice VITALink MC Cables, UL FHIT 120 Installation Instructions Description The VITALink Taped Splice

More information

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate www.cable.alcan.com Type XHHW-2 and Type USE-2/RHH/RHW-2 Alcan manufactures XHHW-2 and

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Installation Instructions: Read these instructions in its entirety before performing any installation work. WIR-TRAN Rated for use on 110/120VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND SPA PRODUCTS ETL

More information

Installation Instructions: ACCENT SYSTEM

Installation Instructions: ACCENT SYSTEM Installation Instructions: ACCENT SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read this entire

More information

MNPV Installation Instructions

MNPV Installation Instructions 14000 Burn Rd Arlington, WA 98223 USA Ph (425)374-9060 www.midnitesolar.com MNPV Installation Instructions The MNPV6 combiner is rated for outdoor use. Designed for combining PV strings up to 150VDC and

More information

PV Vault Yielding safety quickly

PV Vault Yielding safety quickly PV Vault Yielding safety quickly Designed with safety in mind ABB now offers the UL 1741 certified Solar Rapid Shutdown Device, PV Vault rated at 600 V DC to meet NEC 690.12 code requirement for string

More information

Product Manual. Installation Instructions for CHSM-230M Series Solar Module

Product Manual. Installation Instructions for CHSM-230M Series Solar Module Product Manual Installation Instructions for CHSM-230M Series Solar Module CHSM-230M series solar module is made of 60 pieces of 156 mm 156 mm crystalline solar cells in series with high efficiency, high

More information

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07 General Installation Manual for SANYO HIT Photovoltaic Modules. Please read this manual completely before use or installation of SANYO modules. This manual applies to the following models: HIP-205BA3,

More information

SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes

SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes Combiner Manual SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes User Manual U.S. Version 2.4 DOC-CBUG-01 i ii Combiner Manual Combiner Manual Copyright 2012 SMA America, LLC. All rights reserved.

More information

Fronius String Control 250/25. Operating Instructions USA. Data Communication

Fronius String Control 250/25. Operating Instructions USA. Data Communication Fronius String Control 50/5 USA Operating Instructions Data Communication 4,046,008,EA 000 Dear Fronius Customer, Introduction Thank you for choosing Fronius - and congratulations on your new, high-quality,

More information

Safety and Installation Instructions

Safety and Installation Instructions Safety and Installation Instructions This document applies to the following UL-listed Gloria Solar Standard Modules: GSM6- series GSS6- series Rev: 1.2 Release Date: September 03, 2009 Gloria Solar Co.,

More information

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4 INSTALLATION MANUAL IEC Version www.delsolarpv.com Copyright 2012 DelSolar Co. Ltd MQWRD-01-14--installation manual-iec Ver. 1.4 Content General information 1 Safety precaution for installing solar PV

More information

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

Instructions for Installation, Operation and Maintenance of: WSRD Interlocked Receptacles 30, 60 & 100 Ampere 331114-1 INSTRUCTION SHEET Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere Read instructions carefully and with full understanding for safe

More information

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules. Fuseology Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression Optima Fuse Holders & Overcurrent Protection Modules Compact, full-featured modules that deliver Type 2 coordinated protection,

More information

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Solar Power Switchgear & Energy Storage Renewable Energy Systems 7 Solar Power Switchgear & Energy Storage Renewable Energy Systems - Solution Brochure www.apt-power.com 433 N. 36 th Street PROVIDING A COMPREHENSIVE Lafayette, IN 47905 www.apt-power.com 433 APPROACH

More information

Sunny Central Accessories SUNNY CENTRAL STRING-MONITOR US

Sunny Central Accessories SUNNY CENTRAL STRING-MONITOR US Sunny Central Accessories SUNNY CENTRAL STRING-MONITOR US Technical Description SSMUS-TUS094511 98-4001411 Version 1.1 US Copyright 2009 SMA America, Inc. All rights reserved. No part of this document

More information

SunWize SWPB Series Solar Modules GENERAL INSTALLATION & USER GUIDE

SunWize SWPB Series Solar Modules GENERAL INSTALLATION & USER GUIDE SunWize SWPB Series Solar Modules GENERAL INSTALLATION & USER GUIDE Introduction This guide contains application and user safety information you should become familiar with before using your SWPB series

More information

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly. SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS (ELEC) This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

More information

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A Technical Data Effective March 0 Bussmann x38mm Photovoltaic fuses Operating class gpv and UL PV fuse links PV Fuse coordination With thin film cells and, 5 and crystalline silicon cells Description A

More information

MNPVHV Disco Installation Instructions

MNPVHV Disco Installation Instructions MNPVHV Disco Installation Instructions MNPV8HV TYPE 4X MNPV8HV TYPE 3R The MNPVHV combiners are rated for outdoor use. Designed for combining high voltage strings using 10mm x 38mm fuses. The use of touch

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 new sircopv_059_a cat The solution for > Combiner box > Recombiner box > Inverter Function SIRCO PV UL98 non fusible disconnect switches are heavy duty

More information

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems COUNTY OF SANTA CRUZ PLANNING DEPARTMENT 701 OCEAN STREET, 4 th FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 KATHLEEN MOLLOY PREVISICH, PLANNING DIRECTOR Photovoltaic

More information

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D. DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,

More information

Residential Photovoltaic (PV) Packet

Residential Photovoltaic (PV) Packet Development Services Department Building Division 311 Vernon Street Roseville, California 95678-2649 (916) 774-5332 Fax (916) 774-5394 Residential Photovoltaic (PV) Packet The Roseville Municipal Code

More information

Instrument Enclosure Assemblies

Instrument Enclosure Assemblies Instrument Enclosure Assemblies Standard instrument enclosure Instrument enclosures offer a simple solution for the customer who doesn t have the time to install Signet meters into panels. Whether it s

More information

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable Chilicon Power Aug 2016 1 CONTENTS CP-250E Microinverter System... 3 The CP-100 Cortex Gateway... 3 Important Safety Information... 4 Inverter

More information

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates INDUSTRIAL PLUGS A range from 16 A to 600 A 1000 V. Automatic watertightness from IP44 to 66/67. From -40 to +240 C. GRP or metal casing. Reliable & compact. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com

More information

PDX and PX Retrofit Series

PDX and PX Retrofit Series UNIQUE LIGHTING SOLUTIONS PDX and PX Retrofit Series PDX1-1-12-XX PX1-1-12-X-X-XX-65 RETROFIT INSTALLATION GUIDE PDX and PX Series Retrofit WARNING -Retrofit installation must only be performed by a licensed

More information

JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018

JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018 JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018 GANADO OFFICE PHYSICAL ADDRESS: 8925 State Highway 111 E Ganado, TX 77962 Phone: (361)771-4400 BAY CITY OFFICE PHYSICAL ADDRESS: 100

More information

PART A General Conductor Requirements

PART A General Conductor Requirements PART A General Conductor Requirements 6.1 Conductor Insulation Property Table 310.13 of the NEC provides information on conductor properties such as permitted use, maximum operating temperature, and other

More information

GTX UNIT SUBSTATION Installation, Maintenance & Operation Manual

GTX UNIT SUBSTATION Installation, Maintenance & Operation Manual GTX UNIT SUBSTATION Installation, Maintenance & Operation Manual Marina Electrical Equipment, Inc. 100 Warwick Court Williamsburg, VA 23185 REV.1 April 18, 2014 CAUTION Toll Free: 1-855-258-3939 Fax: 1-757-258-3988

More information

Installation Instructions for Lifeline MC: Cable Splice Using Ceramic Standoffs Technical Information Sheet #402

Installation Instructions for Lifeline MC: Cable Splice Using Ceramic Standoffs Technical Information Sheet #402 Installation Instructions for Lifeline MC: Cable Splice Using Ceramic Standoffs Technical Information Sheet #402 Classified by Underwriters Laboratories to UL 2196 for one hour installations For use with

More information

14x12x7 Inch 48 VDC (PoE) Power-Over-Ethernet Powered, Weatherproof & Insulated with Heating System - Model: NB H0N

14x12x7 Inch 48 VDC (PoE) Power-Over-Ethernet Powered, Weatherproof & Insulated with Heating System - Model: NB H0N 14x12x7 Inch 48 VDC (PoE) Power-Over-Ethernet Powered, Weatherproof & Insulated with Heating System - Model: NB141207-4H0N Applications and Features Features: Molded Fiberglass Reinforced Polyester (FRP)

More information

Solar module user manual Conergy PM 225P-250P

Solar module user manual Conergy PM 225P-250P Solar module user manual Conergy PM 225P-250P 1 Introduction 1.1 Short description Conergy PM modules are solar modules for installation in photovoltaic systems. 1.2 About this manual 1.2.1 Subject of

More information

INSTALLATION MANUAL.

INSTALLATION MANUAL. INSTALLATION MANUAL D6M_BxA Series : D6M_B1A / D6M_B2A / D6M_B3A / D6M_B5A D6M_AxA Series : D6M_A1A / D6M_A2A / D6M_A3A / D6M_A5A D6P_BxA Series : D6P_B1A / D6P_B2A / D6P_B3A / D6P_B5A D6P_AxA Series :

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings Your City logo here Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems

More information

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL Photovoltaic (PV) Residential Page 1 of 10 Revision Date: 07/18/2018 INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL INSPECTION CODE: 703 SCOPE: RESIDENTIAL APPLICABLE CODES: 2016 CBC, CRC, CPC,

More information

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

Installation Instructions for Lifeline MC Cable Splice Using Ceramic Standoffs

Installation Instructions for Lifeline MC Cable Splice Using Ceramic Standoffs Technical Information Sheet # 402 Subject: Installation Instructions for Lifeline MC Cable Splice Using Ceramic Standoffs Classified by Underwriters Laboratories to UL 2196 for one hour installations For

More information

100A 225A 400A PATENT PENDING

100A 225A 400A PATENT PENDING HomeRun Combiner Boxes Installation and Operation Manual 100A 225A 400A PATENT PENDING TABLE OF CONTENTS 1.0 Overview 2.0 Introduction 3.0 Important Safety Instructions 4.0 Disconnecting Combiner Box Electrical

More information

Installing Power Components

Installing Power Components This chapter provides instructions on how to install and reinstall power components in the Cisco NCS 4016 chassis. It also covers connecting and disconnecting power and powering on the chassis. The Cisco

More information

Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD

Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD Part: VST ECS-CS3-310 Three Phase VST-ECS-CS3-110 Single Phase Executive Orders: VR-203 VR-204 Version: 1.1 NOTE:

More information

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables Power Connection Kit Installation Instructions Terminator DP-M for use with TEK and HTEK series constant watt heating cables For Power Connection (1 Cable), In-Line Splice Connection, or End Termination

More information

MNPV2, MNPV3, MNPV4, MNPV6 Instructions

MNPV2, MNPV3, MNPV4, MNPV6 Instructions MNPV2, MNPV3, MNPV4, MNPV6 Instructions The MNPV6 combiner is rated for outdoor use. Designed for combining PV strings up to 150VDC and 120 amps total using breakers, or high voltage strings up to 1000VDC

More information

Battery Cables. Wire & Cable

Battery Cables. Wire & Cable Battery Cables Why Use Larger Cable? Low-voltage power systems with inverters can have very high current through the cables that connect the inverter to the batteries. Large AC loads like microwave ovens,

More information

Installation. Symmetra MW. 400 kw 480 V. UPS Summary UPS Summary. Normal Normal X017 X012 X008A X014A X014B X013 X008B X011 X405 X010 X007 X021

Installation. Symmetra MW. 400 kw 480 V. UPS Summary UPS Summary. Normal Normal X017 X012 X008A X014A X014B X013 X008B X011 X405 X010 X007 X021 X008B X010 X007 X021 X022 X012 X008A X014A X011 X405 X013 X017 X014B UPS Summary UPS Summary Installation Symmetra MW 400 kw 480 V Contents Safety...1 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS..........................

More information

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT INSTALLATION AND WIRING INSTRUCTIONS MANUAL 8030 MANUAL PART NUMBER JANUARY 2011. 4304 MATTOX RD. KANSAS CITY, MO 64150 TABLE OF CONTENTS

More information

ARIA Series configuration options and specifications

ARIA Series configuration options and specifications Vynckier Enclosure Systems 271 McCarty St., Houston, Texas 77029 Phone: (713) 374-7850 Toll Free: (888) 837-1114 Fax: (800) 444-1261 www.vynckier.com ARIA Series configuration options and specifications

More information

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

HEAVY-DUTY PLUGS & SOCKETS

HEAVY-DUTY PLUGS & SOCKETS HEAVY-DUTY PLUGS & SOCKETS 315 A/400 A/500 A/600 A Up to 600 A/1 000 V Automatic IP66/IP67 water-and dust-tight Mechanical and electrical interlocking Up to 6 auxiliary and 2 pilot contacts Marine aluminum

More information

Company Switch Installation Instructions and User Manual

Company Switch Installation Instructions and User Manual Lex Products Corporation 15 Progress Drive Shelton, CT 06484 203.363.3738 203.363.3742 Fax Lex West 11847 Sheldon Street Sun Valley, CA 91352 818.768.4474 818.768.4040 Fax www.lexproducts.com info@lexproducts.com

More information

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality Individual & fixed capacitor banks Low Voltage L O W V O L T A G E N E T W O R K Q U A L I T Y Individual & fixed bank Capacitors Description High reliability Well proven features of ABB dry type power

More information

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits

More information

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1 Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear ABB Group February 25, 2015 Slide 1 SafeGear HD arc resistant switchgear 63 ka arc resistant metal-clad air insulated switchgear

More information

Installation, Maintenance, and Operation Manual

Installation, Maintenance, and Operation Manual GTX TM UNIT SUBSTATION Installation, Maintenance, and Operation Manual Rev.3 03-10-15 Marina Electrical Equipment, Inc. 100 Warwick Court Williamsburg, VA 23185 Toll Free: 1-855-258-3939 Fax: 1-757-258-3988

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Open-Style Power Distribution Blocks

Open-Style Power Distribution Blocks I MPDB Series Open-Style Power Distribution Blocks The Next Generation Power Distribution Block (PDB) Ratings: Volts: 1000Vac/DC Amps: 65 to 2260A based on NEC table 310.15(B)(16) 75ºC ampacities Mersen

More information

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33 SECTION V INDEX Product Description Page Number Junction Boxes......................................V-V2 Meter and Instrument Enclosures.......................V24-V Control Centers.....................................V4-V9

More information

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION PULL BOX F SECONDARY SYSTEM Typical grade Pentahead bolts See note 2 Conduit run as specified Plastic or fiberglass for grass areas or Polymer concrete for light duty areas (see notes 2, 3, & 4) Company