Moulded Case Circuit Breaker

Size: px
Start display at page:

Download "Moulded Case Circuit Breaker"

Transcription

1 NS Series NS moulded case circuit breaker is one of the most advanced type breakers in the world, which adopts international advanced design and manufacturing technology. They are suitable for short circuit and overload protection for circuit of AC 690V 0/Hz, rated current from 1A to A.Its rated insulation voltage is 690V. It can make and break the nonfrequently circuit in the normal conditions. It takes protect effect when mouse cage motors nonfrequent start, breaking off working and protecting overload, short circuit and lacking voltage. It complies with IEC97. NS0NP Tripping Characteristics Thermodynamic release (ambient temp+ C) current of 1.0In (cold state) 1.0In (heat state) release (A) inoperative time (h) inoperative time (h) In 6 6 < In 0 0 < In 1 < 1 < < Operational current of magnetic release (A) In±0% In±0% In±0% Current of Release (A) 1 In 0 Thermodynamic release (ambient temp+ C) 1.0In (cold state) inoperative time 1.0In 0In (heat state) (heat state) operative operative time time 7.In (heat state) operative time =h < h min S<Tp S Operational current of magnetic release (A) 1In±0% NS0NP NSNP breaking capacity grade of MCCB: Deconomical type, with overload release on N pole, which making all time, not closing and opening with the other three poles; N standard type; Hhigh breaking capacity type; Lhighest breaking capacity type. NS0D NS0N NS0H NS1D NS1N NS1H NS0D NS0N NS0H NS0D NS0N NS0H NSD NSN NSH Ultimate Servies Operating Arcing short short performance insulation operating over current s circuit circuit voltage voltage distance (A) breaking breaking (times) (V) (V) (mm) capacity capacity ON OFF 1,16,0,,,, 800 0,6,80, ,0,,,,0, ,80,0, 1, ,0,, < ,, ,, 0,00, , ,0, 0,00, 00 00, Tel: Fax: info@ckelectrical.com

2 S Series S moulded case circuit breaker is suitable for circuit AC 0Hz/Hz, rated voltage up to AC V, operating current to 800A. It features normal structure, reliable performance, complete accessories & high breaking capacity, used for power distribution and protecting the circuit and electrical equipment against overload and short circuit. It complies with standard of IEC97. Tripping Characteristics S1/P current of release (A) In 6 6 < In 0 < In 800 Thermodynamic release (ambient temp+ C) 1.0In (cold state) 1.0In (heat state) inoperative time (h) inoperative time (h) 1 < 1 < < Operational current of magnetic release (A) 0In±0% In±0% In±0% Thermodynamic release (ambient temp+ C) Current of Release (A) 1 In 0 1.0In 1.0In 0In 7.In (heat (cold state) (heat state) (heat state) state) inoperative time operative time operative time operative time =h < h min S<Tp S Operational current of magnetic release (A) 1In±0% S0/P S1E S1S S1S S1H S0S S0M S0H S0S S0M S0H Number of Current(A) s 1,16,0,,,, 0,6,80, 0,1 16,0,,,0,6, 80,0, 1,1 0,1, 1,0, 00,, 0 00,, 0,1, 0,0 Insulation Voltage (V) P, P, P Operating Voltage (V) 80 Ultimate Short Servies Short operation Circuit Overall Circuit Breaking performance Breaking Dimensions Capacity(KA) Capacity (KA) (Endurance) AC80v ACv AC80v ACv W DC0 Load Unload L H (0) (690) (0) (690) (P/P) / / /1. 0A0 00 1/. SS SM 0, 00, /80. SH 80 0 S800/P S800S S800M S800H 00,, 700, /80. Tel: Fax: info@ckelectrical.com

3 AB Series AB series moulded case circuit breaker is suitable for industrial or commercial power and lighting with AC 0/Hz, rated working voltage up to ACV/DC0V, rated current up to A. It s a kind of economical breaker with the characters of stable and reliable function, beautiful appearance, small size and long life. It can be used for conversion of line and infrequent starting motor. It can also be attached to install the accessories which have protection function for avoiding lossvoltage, undervoltage.the product can install connection line with front board and back board, it also can be equipped handoperating apparatus or motoroperating apparatus to control in a remote distance. AB1 AB0 ABE0 ABS0 ABE0 ABS0 ABE ABS ABE0 current s (A) P,1,0,0 P,,,1, P 0,0 P,,,1, P 0,0,,0 P,1,0, P 0,,0 P P P P P 1,0,0, P,0,, 7,0 P Max. Service voltage (V) AC DC Ultimate Breaking Capacity Icu According to IEC 97 AC Voltage 00V V 1V 80V V DC Voltage 0V 1V 1,1,0, ABS0 0,,0,,7,0 P ,10, ABE 17,00, P 0 1,10, ABS 17,00, P ABE0 0,00, 0,0 P 0 AB ABS0 0,00, 0,0 P Tel: Fax: info@ckelectrical.com

4 Y Series Y P Y moulded case circuit breaker is one of the most advanced type breakers in the world, which adopts international advanced design and manufacture technology. They are suitable for short circuit and overload protection for circuit of AC 690V 0/Hz, rated current from 1A to A.Its rated insulation voltage is 690V. It can make and break the nonfrequently circuit in the normal conditions. It takes protect effect when mouse cage motors nonfrequent start, breaking off working and protecting overload, short circuit and lacking voltage. It complies with IEC97. Model Y1 Y Y0 Y Y800 Number of s 1P, P P P P P Current (A),,, 0, 6, 80, 0, Lowest Setting Current (A) 1,, 8,,, 6, 70, Y 0P DPX1NP DPX Series DPX1 DPX0 Operating No. Current(A) voltage(v) P,P 16,,,6,0,1 00V P,P,,6,0,1,0 690V Ics(KA)80/1V~ 6 Ics(KA)80/1V~ 1 6 DPX0NP 6 Tel: Fax: info@ckelectrical.com

5 ME Series ME moulded case circuit breaker are highly specified. Positive contact indication is standard, with three positions On OFF and centre TRIPPED being provents the MCCBs contacts from being held closed in the event of over current. The available current is 16A, 0A, A, A, A, 0A, 6A, 80A, 0A, 1A, 1A, 00A, 0A, 00A and 0A. It complies with IEC97 standard. ME1P ME0P HB HB16P HB series is a kind of economic breaker, has the features as following, such as steady and reliable property, reasonable structure, beautiful style, small volume etc. This breaker applies to the circuit with AC0/Hz, rated insulation voltage V, maximum rated current A as onoff operation and take effect. It also can be used as unfrequent conversion of line and unfrequency. Model HB16H HB6H HB6N HB6E Number of s P P P P Current (A) 16, 0,,,, 0, 6, 80, 0 6, 80, 0, 1, 1, 00, 6, 80, 0, 1, 1, 00, 6, 80, 0, 1, 1, 00, Breaking Capacity (ka) 0/V /1V 70 /690V 1 1 HB6P Tel: Fax: info@ckelectrical.com 7

6 VL Series VL1XP VL moulded case circuit breaker is one of the most advanced type breakers in the world, which adopts international advanced design and manufacture technology. They are suitable for short circuit and overload protection for circuit of AC 690V 0/Hz, rated current from 1A to A.Its rated insulation voltage is 690V. It can make and break the nonfrequently circuit in the normal conditions. It takes protect effect when mouse cage motors nonfrequent start, breaking off working and protecting overload, short circuit and lacking voltage. It complies with IEC97. Model Number of s Current (A) Ultimate Short Circuit Breaking Capacity (KA) Servies Short Circuit Breaking Capacity (KA) Operation Performance ON OFF VL1D 16, 0,, VL1N VL1H,, 0, 6,, 0, VL1L P, P 1, VL0XP VL0N VL0H VL0L 0,, HFD Series HFD series is a kind of economic breaker, has the features as following, such as steady and reliable property, reasonable structure, beautiful style, small volume etc. This breaker applies to the circuit with AC0/Hz, rated insulation voltage V, max.rated current 0A as onoff operation, and take effect, it also can be used as unfrequent conversion of line and unfrequency. HFD1NP The available current is 1A, 0A, A, 0A, A, A, 0A, 70A, 90A, 0A, 1A, 10A, 17A, 00A, A and 0A. HFD0NP 8 Tel: Fax: info@ckelectrical.com

7 NFCS Series NF0CS P NFCS series is a kind of economic breaker, has the features as following, such as steady and reliable property, reasonable structure, beautiful style, small volume, etc. This breaker applies to the circuit with AC0/Hz, rated insulation voltage V, max.rated current A as onoff operation, and take effect, it also can be used as unfrequent conversion of line and unfrequency. NF 0CS NF0CS NFCS NF0CS NF0CS NF0CS NFCS NF800CS NFCS Number (P),,,,,1,0,0,1,0,0,,0,70,0 1,10,17,00,,0 0,00,0,0 00,,,700, ,00,, current of frame (A) ultimate breaking capacity (KA) / / / / /0 8 NF0CS P NFSS NFSS series is a kind of economic breaker, has the features as following, such as steady and reliable property, reasonable structure, beautiful style, small volume, etc. This breaker applies to the circuit with AC0/Hz, rated insulation voltage V, max.rated current A as onoff operation, and take effect, it also can be used as unfrequent conversion of line and unfrequency. NF0SS P NF0SS number current(a),,,1,0,0 / Breaking capacity(ka) AC(P1/P) 80 / 1 / 00 /1.0 NF0SS NFSS NF0SS,0,0,,0,0,0,,0,,7,0 / / 0/ / / 0/0 / / / / / 1/ / / / / NF0SS NF0SS 1,10,17,00,,0 0,00,0,0 0/ 8/ 0/ 0/ /1 /0 /1 / 1/ / / 1/ NFSS 00,, 8/ 0/ 0/0 / / 1/ NF0SS P NF800SS,700,800 8/ 0/ 0/0 / / 1/ Tel: Fax: info@ckelectrical.com 9

8 NFCP NFCP series is a kind of economic breaker, has the features as following, such as steady and reliable property, reasonable structure, beautiful style, small volume, etc. This breaker applies to the circuit with AC0/Hz, rated insulation voltage V, max.rated current 0A as onoff operation, and take effect, it also can be used as unfrequent conversion of line and unfrequency. NF0CP P Model Number current (A) (P1/P) lca/lcs Breaking capacity (KA) NF0CP,,1,0,0,,0 / / /1 /1 NFCP / / /1 /1 NF0CP,7,0 /1 / / 7/ NF0CP 1,10,17,00,,0 0/1 /9 1/8 / NF0CP 0,00,0,0 0/ 6/ /1 1/8 NF0CP P NFCW NFCW series is a kind of economic breaker, has the features as following, such as steady and reliable property, reasonable structure, beautiful style, small volume, etc. This breaker applies to the circuit with AC0/Hz, rated insulation voltage V, max.rated current 800A as onoff operation, and take effect, it also can be used as unfrequent conversion of line and unfrequency. Circuit breaking capacity(ka) number current(a) AC(P1/P) NF1CW P NF0CW,,,1,0,0 / 80 / 1 / 00 /1.0 NF0CW NFCW NF0CW,0,0,,0,0,0,,0,,7,0 / / 0/ / / 0/0 / / / / / 1/ / / / / NF0CW NF0CW 1,10,17,00,,0 0,00,0,0 0/ 8/ 0/ 0/ /1 /0 /1 / 1/ / / 1/ NFCW 00,, 8/ 0/ 0/0 / / 1/ NF0CW P NF800CW,700,800 8/ 0/ 0/0 / / 1/ Tel: Fax: info@ckelectrical.com

9 EA SA The circuit breaker is suitable for industrial or commercial power and lighting circuit. Its rated working voltage is V up to 1V (AC 0Hz). It can be used to protect the circuit that overload or short circuit may take place and also for protecting the circuit which is not frequently in makebreak operation under normal conditions. Breaking SAB capacity (KA) voltage (V) EA,,,1,0,0 1 EA,,,1,0,0 1 EA 1,0,0,,0 EA 1,0,0,,0 EA6 EA6 EA,7,0 EA,7,0 EA0 1,10,17,00, EA0 1,10,17,00, SAB EA 0,00,0,0 Breaking capacity voltage (V) (KA) SA,,,1,0,0 SA,,,1,0,0 SA 1,0,0,,0 SA 1,0,0,,0 SA6 SA6 SA 1,0,0,,0,,7,0 1 SA0 1,10,17,00, SA0 1,10,17,00, EAB SA 0,00,0,0 Tel: Fax: info@ckelectrical.com 1

10 GV Motor Protection Circuit Breaker GV series motor protection circuit breakers are mainly used for the overload and short circuit protection of the motor in AC 0/Hz, up to V, 0.0A power circuit, as a fullvoltage starter to start and cut off the motor, under the AC load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. GV standard power of phase 0V KW motors 0/Hz in category AC 80V KW 1V KW V KW 00V KW V KW Setting range (A) GVM GVM GVM GVM GV GVM0 GVM GVM GVM GVM GVM1.. 6 GVM GVM GVM GVM GVM GVM GVM GVM GVM GVM1.. 6 GVM0 16 GVM GVM. GVM GVM Tel: Fax: info@ckelectrical.com

11 M6 Motor Protection Circuit Breaker This product is suitable for using in circuit up to AC V or V and current 0.1 to 6A. It can be used for protection of overload and short circuit of phase squirrelcage motors, and starters of motors as well at full voltage. It is suitable to protect the motor with under voltage trip. It can also be used in operating AC single phase load and DC load. It can monitor the fuse of switch disconnector to act as protection of phase failure. This product includes basic type switch and 6 accessories with purposes of expanding usage. It complies with standard of IEC97. M fixed current (A) 0.1~ ~0. 0.~0. 0.~ ~ ~ fixed current (A) 1.6~ ~.0.0~6. 6.~ 9.~16 1~0 6 fixed current (A) 19~ 0~ 0~ ~6 Characteristic Curve M6 Enclosed type Dimensions 7max.. 7 8max I 8 1max I 8 1max 0±0. 0±0. max 61 max 68 M616 M6 Tel: Fax: info@ckelectrical.com

12 VE Motor Protection Circuit Breaker VE Motor protection circuit breaker is suitable in AC circuit of 0Hz or Hz, voltage up to V and current up to 0.16A and used to prevent small capacity motor and circuits from overload and short circuit. It can be also used as direct starter for starting the motor and a switch for changeover the circuit under normal conditions. Voltage (V) Insulation Voltage (V) Current Setting Range (A) Power of 0V Controlled 80V Motor (KW) V Mechanical life (1 ) 1.0Ie Protective 1.Ie Feature 1Ie VE1 VE ~ ~0. 0.~0. 0.~0.6 1~ ~ 0.6~1 1~1.6 ~ ~6. 1.6~ ~. 6.~ 8~1 ~.~ ~6. ~8 ~16 1~0 6.~ 8~1 16~ ~ ~6 1~ Not Act Within hrs Act Within hrs Action Snap VE ~ ~16 16~ ~ 8~ 6~0 ~6 ~6 8 VU1 Motor Protection Circuit Breaker The product is suitable to be used in circuit of rated voltage up to AC V 0/Hz, rated current from 0.1A to 6A. It is applicable for protection of overload & short circuit of phase squirrelcage motors. It also can be used as direct starter to start the motor and a switch for changeover the circuit under normal conditions. UV0 VU1 Current Setting Range (A) 0.1~0.16, 0.16~0., 0.~0., 0.~0.6, 0.6~1, 1~1.6, 1.6~., ~.,.~,.~, ~6, ~8, 6~, 8~1, ~16, 1~0, ~ 1~1.6, 1.6~.,.~, ~6, 6~, ~16, 16~, ~, 8~, 6~, ~6 Tel: Fax: info@ckelectrical.com

ELECTRIC PRODUCT CATALOGUE

ELECTRIC PRODUCT CATALOGUE ELECTRIC PRODUCT CATALOGUE!"#$%&' www.cetelec.com.cn SHANGHAI CET ELECTRIC CO. LTD. is one of the leading and the most reliable manufacturers and exporters for low voltage and high voltage electric products

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

The new SH200 MCBs can be used in domestic, commercial and industrial applications for protection against over-current and short circuit.

The new SH200 MCBs can be used in domestic, commercial and industrial applications for protection against over-current and short circuit. s Product Overview SH200 The new SH200 s can be used in domestic, commercial and industrial applications for protection against over-current and short circuit. New Enhancement Optimized connection terminal

More information

KM1 Series Moulded Case Circuit Breaker

KM1 Series Moulded Case Circuit Breaker KM1 KM1 Series Moulded Case Circuit Breaker 1. Application KM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

MM5 Series High Breaking Mini Circuit Breakers

MM5 Series High Breaking Mini Circuit Breakers MM5 Series High reaking Mini ircuit reakers M Series A Series M Series ATS Series Load-isolating Series ontrol Appliance Series Product overview MM5 mini circuit breaker has novel structure, reliable performance,

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

Siemens switchgear. Tried, tested, trusted. Circuit Breakers

Siemens switchgear. Tried, tested, trusted. Circuit Breakers * MP - Maximum etail Price Siemens Ltd. LV SG - Power Distribution Products MP Eff. 01-10-2014 13 MCCB: Sentron 3VT1...5 ated current - 16A to 1600A 3 and 4 pole versions Breaking capacity from 25kA to

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

- Moulded-case Circuit Breaker

- Moulded-case Circuit Breaker Safety Protection Catalogue 2013/2014 - MAXTRIC circuit breaker Working with the world s electric specialist together @ Cat. No. CM1 1. Application CM1 series moulded case circuit breaker is one of products

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Electronic circuit breaker EBU10-T

Electronic circuit breaker EBU10-T Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions

More information

DZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection

DZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection DZ47LE 1P+ DZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection DZ47LE C45LE RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

CHINT. NM7 Moulded Case Circuit Breaker

CHINT. NM7 Moulded Case Circuit Breaker CHINT Moulded Case Circuit Breaker Moulded Case Circuit Breaker Application Product introduction Functions and characteristics Accessories Overall and dimension Specification selection and order Page

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field

More information

SENTRON VL Series Product Specifications

SENTRON VL Series Product Specifications SENTRON VL Series Product Specifications VL 400 Frame 400 s Electronic Releases ETU TRIP RELEASE 315 12-315 3VL4731 - A 3-0AA0 400-400 3VL4740 - A 3-0AA0 3 = 3 poles All VL400 circuit-breakers are shipped

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00 2 4a Fuse-link

More information

Industrial Protection Products Edition

Industrial Protection Products Edition Industrial Protection Products 2016 Edition COMPANY PROFILE Shanghai Liangxin Electrical Co., LTD. one of the leading low-voltage electrical component manufacture in the high-end market, was established

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

ACS motor protection circuit breakers KT 7 Introduction

ACS motor protection circuit breakers KT 7 Introduction Introduction Automatic Type 2 coordination The right circuit breaker for all applications The KT 7 circuit breaker family consists of two basic frame sizes of mm and 5 mm in three variations with different

More information

Motor Protection Circuit Breaker

Motor Protection Circuit Breaker Motor Protection Circuit Breaker Catalogue 2011 CONTENT Introduction...4 Features...4 Parts Identification...5 Technical information (MPCB)...5 Technical information (Aux. contact, Fault signalling contact)...6

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Selective main circuit breakers S 750 series Technical Data

Selective main circuit breakers S 750 series Technical Data Selective main circuit breakers S 750 series Technical Data When connecting aluminium conductors ( 4 mm 2 ) ensure that the contact surfaces of the conductors are cleaned, brushed and treated with grease.

More information

Low breaking capacity moulded case circuit breakers

Low breaking capacity moulded case circuit breakers New series EB2S of MCCBs has excellent performances with reduced dimensions and new modern design. Advantages of low breaking capacity MCCBs Unique accessory cover opens with only one screw. Practical

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

QUALITY ASSURANCE & DOCUMENTATION

QUALITY ASSURANCE & DOCUMENTATION QUALITY ASSURANCE & DOCUMENTATION RTECK IMPORTED PRODUCT STATEMENT Rteck has sourced most product from a large and reputable Chinese product manufacturer who specialise in the manufacture of modular electrical

More information

NEW. Moulded Case Circuit Breakers New DU Series 20 A to 250 A

NEW. Moulded Case Circuit Breakers New DU Series 20 A to 250 A NEW Moulded Case Circuit Breakers New DU Series 0 A to 50 A About us Larsen & Toubro is a technology-driven USD 7 billion company that infuses engineering with imagination. The Company offers a wide range

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33 BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

Miniature circuit-breaker (MCB) SH200M Series

Miniature circuit-breaker (MCB) SH200M Series Miniature circuit-breaker (MCB) SH200M Series 25 mm² cage terminals, a well proven and reliable technology. IP20 - finger safety. Scratch and solvent resistant marking due to laser printing. Easy identification

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.

NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD. Shanghai Liangxin Electrical CO., LTD. - Liangxin Electrical - All rights reserved Address: No. 66 eng An Road, Pu Dong New District, Shanghai Post code: 07 Tel: 6--479 Fax: 6--5675966 E-mail: client@sh-liangxin.com

More information

ADS7 AC Contactor Starters

ADS7 AC Contactor Starters ADS7 AC Contactor Starters ADS7 starters fully comply with BS EN 60947-4-1, IEC 60947-4-1 and VDE 0660. The range offers a multitude of configurations and optional features including a complete choice

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Motor Protection Circuit Breakers 3VU13 and 3VU16

Motor Protection Circuit Breakers 3VU13 and 3VU16 Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection

More information

Short-circuit current limiter S800-SCL-SR

Short-circuit current limiter S800-SCL-SR Short-circuit current limiter S800-SCL-SR 2 ABB Short-circuit current limiter S800-SCL-SR Self-resetting current limiting module S800-SCL-SR is ABB s innovative self-resetting current limiting module which

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

Molded Case Circuit Breaker

Molded Case Circuit Breaker & The Ultimate Safety Breaker Molded Case Circuit Breaker www.terasaki.co.jp Catalogue No. 13!5E ! Safety Notice Carefully read instruction manual to ensure proper installation, connection, operation,

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Motor Protection Circuit Breakers

Motor Protection Circuit Breakers Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS Varius SUMMARY OF MODELS Type FH00 FH1 FH2 FH3 LTL4a Rated operating current I e 160 A 160 A 250 A 400 A 630 A 1 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00

More information

Motor Starting Solutions Open Type Version, in Kit Form

Motor Starting Solutions Open Type Version, in Kit Form Motor Starting Solutions Open Version, in Kit Form Starters Protected by Manual Motor Starters Direct-On-Line Starters I> Reversing Starters I> MS... Manual motor starter MS... Manual motor starter BEA...

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Safety Protection. Catalogue 2013/2014 Contactor & Overload Relay MAXTRIC. circuit breaker.

Safety Protection. Catalogue 2013/2014 Contactor & Overload Relay MAXTRIC. circuit breaker. Safety Protection Catalogue 03/0 Contactor & Overload Relay MAXTRIC circuit breaker Working with the world s electric specialist together @ www.huayuelectric.com AC Contactor series AC Contactors, 3P AC

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W SCHRACK-INFO Lift and clamp terminals on both sides Terminal guide for secure connection Terminal cross-section: 1-25mm² Snap-on mounting for

More information

Compact NR630. NR100F to NR630F

Compact NR630. NR100F to NR630F Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in

More information

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control

More information

Technical Section: Miniature Circuit Breakers

Technical Section: Miniature Circuit Breakers MCBs and Accessories Data. Calibration With CBI Hydraulic- Magnetic Miniature Circuit Breakers, there is no effect on the fixed trip point at ambient temperature ranges from -5 C to +60 C. 2. Products

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Overcurrent releases - description, specifications, characteristics specifications specifications description... BA5*37 COMMERCIAL INFORMATION Type designation specification for ordering...68 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS 87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084

More information

Devices for switching and control

Devices for switching and control Devices for switching and control WWWOEZCOM Motor starters MOTOR STARTERS SM Basic function Switching and protection of motors up to 2 A Protection against short-circuit and protection against overload

More information

DZ518(GV2)Motor protection circuit breaker

DZ518(GV2)Motor protection circuit breaker Main Purpose DZ518(GV2-ME) DZ518 (GV1,GV2,GV3)the series electric motor protection circuit breaker,uses the modular design,the contour is artistic,the volume is small,breaks protects,inside sets Hot Relay,the

More information

SWITCH FUSES 3KL71 from 32A to 800A Description

SWITCH FUSES 3KL71 from 32A to 800A Description from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used

More information

Softstarter Intelligent Controllers

Softstarter Intelligent Controllers Softstarter Intelligent Controllers Series Modes of Operation (Standard) Soft Start 100% Percent Voltage Initial Torque Start Run This method has the most general application. The motor is raised from

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

atalog Welcome to ATO.com! Contact us... Tel: (Toll-free) Website:

atalog Welcome to ATO.com! Contact us...   Tel: (Toll-free) Website: atalog Welcome to.com! Contact us... Email: sales@ato.com Tel: +1 800-585-1519 (Toll-free) Website: ZMQ2E Series Dual Power Automatic Transfer Switch (ATS) Applications ZMQ2E dual auto transfer switch

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

Data Sheet Manual Motor Starters Ex9SN Series

Data Sheet Manual Motor Starters Ex9SN Series Data Sheet Manual Motor Starters Ex9SN Series www.noarkusa.com NOARK Ex9SN Series Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

ย ห อ ประเภทส นค า หน า

ย ห อ ประเภทส นค า หน า 4 Moulded case circuit breaker เซอร ก ตเบรกเกอร ย ห อ ประเภทส นค า หน า THERMAL MAGNETIC CIRCUIT BREAKER เซอร ก ตเบรกเกอร ร น EZC-100N NO FUSE BREAKERS เบรกเกอร ร น NF-CS, NF-CP THERMAL MAGNETIC CIRCUIT

More information

Intelligent Choice for Prestigious Buildings

Intelligent Choice for Prestigious Buildings Intelligent Choice for Prestigious Buildings Table of Contents I-LINE Moulded Case Circuit Breakers General Characteristics 16A to 160A 125A to 250A 250A to 600A 300A to 800A 630A to 1250A 2/3 4 5 6 6

More information

MOLDED CASE CIRCUIT BREAKERS

MOLDED CASE CIRCUIT BREAKERS MOLDED CASE CIRCUIT BREAKERS S series E series Handle-operated type Distribution breakers F series H series Solid-state trip type -pole S and E series INDIVIDUAL CATALOG from D&C CATALOG 9th Edition 0

More information

Thermal magnetic and trip-free switches

Thermal magnetic and trip-free switches 87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/

More information

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection

More information

CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB)

CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB) CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker 02 Part II Molded Case Circuit Breaker(MCCB) 07 UEM5 series Molded Case Circuit Breakers 08 UEM5L series

More information

SPECIFICATION OF CIRCUIT BREAKER

SPECIFICATION OF CIRCUIT BREAKER SPECIFICATION OF CIRCUIT BREAKER Principle of operation 1, Principle of operation of hydraulic magnetic circuit breaker (see drawing 1) The circuit breaker adopts a hydraulic magnetic tripper to protect

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System pro M compact

More information

UEW5 series intelligent air circuit breaker

UEW5 series intelligent air circuit breaker UEW5 series intelligent air circuit breaker UEW5 series intelligent air circuit breakers are applicable to the power distribution circuit under the condition of AC50Hz/60Hz, rated working voltage 400V

More information

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950. Vol. 1, Ref. No. [0559] - Amperes M-Frame 12-93 % Rated Digitrip OPTSM s with interchangeable Rating Plugs Order as individual components: Frame (which includes Trip Unit), Rating Plug, Terminals. Table

More information

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V. Function CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit

More information