- Moulded-case Circuit Breaker

Size: px
Start display at page:

Download "- Moulded-case Circuit Breaker"

Transcription

1 Safety Protection Catalogue 2013/ MAXTRIC circuit breaker Working with the world s electric specialist

2 Cat. No. CM1 1. Application CM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied with rated insulating voltage 550 and 800V and used for circuit of AC 50/60Hz, rated operating voltage AC 400V (or below), rated operating current up to 1600A for infrequent changing over and starting of the motors.the products conforms to IEC Technical Specification Cat. No. Rated Current (A) Pole No. Rated Insulation Voltage (V) Rated Operation Voltage (V) Arcingover dis. (mm) Ultimat Short Circuit Breaking Capacity (KA) Service Short Circuit Breaking Capacity (KA) CM1-63L (6), 10, 16, , 25, 32, 500V CM1-63M 40, 50, CM1-100L (10), 16, 0( 50) CM1-100M 20, 25, 32, 40, 50, 63, 0( 50) CM1-100H 80, 100 0( 50) CM1-225L , 125, 3 Pole CM1-225M 160, 180, , Pole CM1-225H CM1-400L 225, 250, , 350, CM1-400M 400V CM1-630L 800V CM1-630M 400, 500, CM1-630H CM1-800M 630, 700, CM1-800H CM1-1250M 1000, 3 Pole CM1-1250H Operation Performance Load Unload CM1-1600M Note: 6A without thermal protection The N-pole of four-poles breaker is sited at the right side of the product has four types: Type A: Without current trip-lease on N pole which making all the time, not closing and opening with the other three poles. Type B: Without current trip-release on N pole which closing and opening with the other poles. Type C: With current trip-release which closing and opening with the other three poles. Type D: With current trip-release which making all the time not closing and opening with the other three poles. Utilization Category 3. Protection Characteristic The thermodynamic release of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) and table 3 (motor protection circuit breaker). Rated current of Thermodynamic release( ambient temperature ) land +40 C marine +45 C release (A) 1.05In(cold state) Inoperative time(h) 1.30In(heat state) Operative time(h) Operating current of magnetic release (A) 10 In 63 1 < 1 63<In < 2 10In±20% 100 In < 2 5In±20% 10In±20% A Rated current of release (A) Thermodynamic release( ambient temperature ) land +40 C marine +45 C 1.0 In(cold state) non-trip time(h) 1.20 In(heat state) trip time(h) 1.50In(heat state) trip time (h) 4min 7.2In(cold state) trip time(h) 4s < Tp 10s 10 In < 2 225<In 630 8min 6s < Tp 20s Operating current of magnetic release (A) 10In±20% 2

3 4. Accessories 4.1. Motor-driven operation device 1) Wiring diagram of type CDM electromagnetic operation device(fitting AM1-63,100,225) seethe following drawing (wiring diagram of the external accessories of the breaker in the dotted frame) Code description: SB1 SB2 stand for push button.(provided by users themselves) Number stand for number of wiring terminals. Voltage rating: AC50Hz 230V 400V DC 220V 2) Wiring diagram of type CD motor-driven operation device (fitting AM ) seebelows (wiring diagram of the external accessories of the breaker in the dotted frame) Code description: SB1 SB2 stand for push button. (provided by users themselves) X stands for line connection terminals Voltage rating: AC50Hz 230V 400V DC 220V 4.2. Rotary handle operation device The mechanism is used in moulded case circuit breaker to operate the draw-out panel. Powerdistribution panel and supply box outside the panel by turning the handle,and to ensure thedoor of panel would not be openned when the breaker being on. The hand-drive mechanism can be equiped with two types of operation, one is A modelsquare handle, the other is B model round handle Release pattern and accessories code SHT: Shunt release; UVR: Under-voltage release;ax: Auxiliary contact; AL: Alarm contact Release patternand accessories code Name/Type AM1-63, 100, 225 AM1-400 AM1-630 AM , 300 No accessories 200: magnetic release (only short circuit protection)300: thermal magnetic release(both overload and short circuit protection) 208, 308 Alarm contact 210, 310 Shunt release 220, 320 Auxiliary contact 230, 330 Under-voltage release 240, 340 Shunt release Auxiliary contact 250, 350 Shunt release Under-voltage release 260, 360 Two group of auxiliary contact 270, , 318 Under-voltage release Auxiliary contact Shunt release Alarm contact 228, 328 Alarm contact Auxiliary contact 238, 338 Under-voltage releasealarm contact 248, 348 Shunt release, Alarm contact,auxiliary contact 268, 368 Two group of auxiliary contact,alarm contact 278, 378 Shunt release, Alarm contact, Under-voltage release 3

4 Note: accessories could lead to direct wire outcoming or line wiringterminals could be added(please mark out in case of making order). According to user s demands 4.4. Under-voltage release Wring diagram of the under-voltage module connected externally (the internal accessories inthe dotted frame)ue: AC50Hz 230V, 400V. When the operation voltage is 35%~70% of the rated voltage, the undervoltage release shouldmake the breaker trip correctly.when the operation voltage is 85%~110% of the rated voltage, the under-voltage release shouldmake the breaker close.in case of the operation voltage less than 35% of the rated voltage, the under-voltage shouldprevent the breaker from closing.note: Only the under-voltage release should be energized in advanced, the breaker could berecramped and turned-on, otherwise the breaker will be damaged Shunt release Scheme of wiring(the internal accessories in the dotted frame) K is the slow motion switch normal-close contact connect the coil in series in the shunt release.it turns-on or turns-off voluntarily as soon as the breaker on or off. Voltage rating: AC50Hz 230V or 400V, DC 110V 220VThe shunt release should make the breaker trip reliably when the operation voltage is 70%~110%of the rated control voltage Alarm contact The position of the breaker in off or on The position of the breaker in free trip (alarm) B11 and B12 switch from close to open, statusof B11 and B14 switch from open to close 4.7. Auxiliary contact For the breaker with frame current400a and above When the breaker is in off For the breaker with frame current225a and below When the breaker is in on When the breaker is in off, the contacts switch from close to open. When the breaker is in off,the contacts switch from open to close 5. Outline and dimentions 4

5 Cat. No. Dimension of Front panel connection (mm) W W1 L L1 L2 H H1 H2 H3 H4 C D E F G W2 W3 CM1-63L CM1-63M CM1-100L CM1-100M CM1-100H CM1-225L CM1-225M CM1-225H CM1-400L φ CM1-400M φ9 CM1-630L φ CM1-630M φ9 CM1-630H CM1-800M CM1-800H CM1-1250M CM1-1250H CM1-1600M Cat. No. Dimension of Back panel connection (mm) Dimension of Pluge-in connection (mm) Installation Di. (mm) L4 H5 H6 φd φd1 L5 L6 H7 H8 H9 H10 J K φd1 M A B φd CM1-63L CM1-63M CM1-100L M CM1-100M M CM1-100H M CM1-225L M CM1-225M M CM1-225H M CM1-400L M CM1-400M M CM1-630L M CM1-630M M CM1-630H CM1-800M CM1-800H CM1-1250M CM1-1250H CM1-1600M 5

6 6 Cat. No. CM1L 1. Application CM1L series earth leakage circuit breaker are one of the new type earth leakage breakers which have been developed by the company using international advanced design and manufacturing technology. Suitable for a line of AC50Hz/60Hz, rated voltage up to 400V, rated current 16A to 630A. and is acted as infrequent changeover of circuit or infrequent starting of motor. The breaker has overload, short-circuit and under-voltage protective function, which can protect the circuit and the power equipment against damage, meanwhile, it can provide protection to these fire dangers that caused by these long-time existed grounding fault that can not be detected by the over-current protection. This breaker can be installed vertically(upright) or horizontally(transverse). Wiring of the breaker can not be in adverse direction, that means power supply line must be connected to terminal 1,3 and 5,and the load line connected to terminal 2, 4 and 6. The rated residual operating current I n and the maximum breaking time can be adjusted on site according to practical condition. The leakage protection module still can work normally when the phase voltage reduce to 50V. It has the same overall size with the AM1 series breakers, which make the installation more exchangeable. The breakers are suitable for isolation, its symbol are: The breakers comply with the demands of the following standards: IEC : General, IEC : Low voltage breakers, IEC : Contactors and motor starters IEC : Electrical equipments of electromechanical control circuit 2. Technical Specification Cat. No. CM1L-100 CM1L-225 CM1L-400 CM1L-630 Frame Current Inm(A) Rated current In(A) (10)16, 20, 25, 32, 40, 50, 63, 80, , 125, 160, 180, 200, , 250, 315, 350, , 500, 630 Pole Number Rated Insulation Voltage Ui(V) AC 800V AC 800V Rated Working voltage Ue(V) AC 400V AC 400V Rated impulse with stand voltage Uimp(V) Arc-over Distance(mm) > 50 > 50 Breaking capacity grade M H M H M M Limiting short-circuit breaking capacity lcu (ka) AC400V Service short-circuit breaking capacity lcs(ka) AC400V Rated residual operating current I n(ma) Non-delay type 100/300/ /300/500 Delay type 100/300/ /300/ /500/1000 Rated residual nonoperatingcurrent I no(ma) 1/2 I n 1/2 I n Operation performance (time) Electrified Un-electrified Note: According to the pole number of product, it calssifies three and four poles. The neutral pole (N-Pole) of the four-poles products has four types: Type A: N-pole without over-current release unit, it has been connected all the time, not closing and opening with the other three poles. Type B: N-pole without over-current release unit, which closing and opening with the other three poles. Type C: N-pole fixed with over-current release unit, which closing and opening with the other three poles. Type D: N-pole fixed with over-current release unit, it has been connected all the time, not closing and opening with the other three poles. 1. The limiting breaking and arc-over distance includes horizontal and vertical installation. 2. If the three-pole breaker of this series is connected with three phase load, the load can not have neutral line, otherwise the breaker will have fault action. 3. If the three-pole breaker of this series is connected with single phase load, the phase line willbe connected to the left pole, and the neutral line is connected to the right pole, the middle pole is blanket

7 3. Protection Characteristic The thermal release of the breaker has again-time-limit property; the electromagnetic release is inst. Operation, its property see table 2(for distribution),table 3 (motor protection). Thermal release (ambient temperature+40 o C) Electromagnetic release operating Rated current of Release(A) 1.05In(cold state ) non-operating time (h) 1.03In(hot state) acting time (h) current(a) 10 In In±20% 63 In In In±20% 10In±20% Rated current of Release 1.0In (cold state) nonoperating time(h) Thermal release (ambient temperature +40 o C) 1.20In(hot state) acting time(h) 1.50In(thermal state) operating time 7.2In(cold state) operating time Electromagnetic Release operating current(a) 10 In min. 6s < TP 20S 12In±20% 4. Residual current operating time of earth leakage circuit breaker 4.1 Non-delay type operation characteristics see table 4(I n 30mA should be Non- delay type) Rated current I n 2I n 5I na 10I n Non-delay type Max.breaking time(s) Note: ato I n 30mA earth leakage circuit breaker, 0.25A can instead of 5I n According toa, adopt 0.25A, then 10 I n is 0.5A. 4.2 Delay type operation characteristics Limiting non-driven time of delay type earth leakage circuit breaker according to 2l n,operation characteristics Delay time (s) Max. breaking time(s) at I n Limiting non-driven time (s) at 2 I n Max. breaking time(s) Max. breaking time(s) at 5I n Max. breaking time(s) at 10 I n Accessories Motor-driven operation device 1) Wiring diagram of type CDM electromagnetic operation device(fitting CM1L-100,225) see thefollowing drawing (wiring diagram of the external accessories of the breaker in the dotted frame) 2) Wiring diagram of type CD motor-driven operation device (fitting CM1L- 400I630) see belows(wiring diagram of the external accessories of the breaker in the dotted frame) Code description: SB1 SB2 stand for push button.(provided by users themselves) Number stand for number of wiring terminals. Voltage rating: AC50Hz 230V 400V, DC 220V Code description: SB1 SB2 stand for push button. (provided by users themselves) X stands for line connection terminalsvoltage rating: AC50Hz 230V 400V; DC220V Rotary handle operation device The mechanism is used in moulded case circuit breaker to operate the draw-out panel. Powerdistribution panel and supply box outside the panel by turning the handle,and to ensure thedoor of panel would not be openned when the breaker being on. The hand-drive mechanism can be equiped with two types of operation one is A modelsquare handle, the other is B model round handle. **OTHER ACCESSORIES ARE ALSO AVAILABLE. 7

8 Cat. No. CM5 1. Applications CM5 series moulded case circuit breaker is one of breaker which adopts international ad-vanced design, manufacture technology to develop. The rated insulating voltage is 750V, suit-able for AC 50Hz(60Hz),rated working voltage 690V or below, rated working current is 12.5A to1250a of circuit and used in distributing electric energy, and non-frequent breaking in the nor-mal conditions, protecting the current& equipment from overload&under voltage, circuit breakerwith rated frame current 400A or below,can be used in mousecage motor s non-frequent start,breaking during working, protecting motor from overload, short circuit&undervoltage,the prod-uct conforms to IEC standard 2. Technical Specificatioins Cat. No. Pole No. Rated Insulation voltage (V) Rated Operating Voltage (V) Rated ultimate short circuit breaking capacity Icu (KA) AT 380/415v Rated service short circuit breaking capacity Ics (KA) at 380/415V CM5-100N CM5-100H CM5-100L CM5-160N CM5-160H CM5-160L CM5-250N CM5-250H 3 Pole, Pole CM5-250L V or less CM5-400N CM5-400H CM5-400L CM5-630N CM5-630H CM5-630L CM5-1250N Pole CM5-1600N Note: 1. The N-pole breaker has no protection which closing and opening with the other three poles. 2. The type of thermal magnetic for AM2-400/630 has no four poles. 3. Technical parameter of Trip units 3.1 Thermal magnetic release Operation Performance ON OFF Utilization category A 8

9 Cat. No. Rated Current In(A) Note CM , 16, 20, 25, 32, 40, 50, 63, 80, 100 CM , 20, 25, 32, 40, 50, 63, 80, 100, 125, 160 CM , 180, 200, 225, 250 Tadjustable (0.8~1In)M adjustable (5~10In) CM , 350, 400 CM , 500, 630 CM , 1000, 1250 CM , 1250, 1600 Tadjustable (0.8~1In)M fixed 3.2 Electronic release 1. Overload protection with adjustable threshold 2. Short-circuit protection with adjustable threshold 3. Load indication: light at 90% of Ir setting threshold; Flashing at 105% or more of Ir setting threshold Cat. No. Rated Current In (A) Note CM ,100 Ir=0.4~1 In(adjustable 48 setting) Tripping between 1.05~.3 Ir (IEC ) CM ,100,160 (Long-time overload protection) CM ,100,160,250 Im= Ir (Short-circuit protection) 3.3 CM5 22ME: Motor Protection for CM5-100/160/ Overload protection with adjustable threshold, as defined by IEC (2) tripping class Short-circuit protection with fixed threshold (13xIr) 3. phase failure protection (tripping time delay between 3.5s-6s) 4. Load indication : dark less than 105% of Ir setting threshold; Flashing at 105% or more of Ir setting threshold Cat. No. Rated Current In (A) Note CM , 50, 80, 100 CM , 50, 80, 100, 150 Ir= In CM , 50, 80, 100, 150, 220 9

10 3.4 CM5 23SE: LV distribution networkd protection for CM5-400/ Overload protection with adjustable threshold 2. Short-circuit protection with adjustable threshold 3. Load indication : light at 90% of Ir setting threshold; Flashing at 105% or more of Ir setting threshold Cat. No. Rated Current In (A) Note CM5-400 CM Ir=0.4~1 In(adjustable 48 setting) Tripping between 1.05~1.3 Ir (IEC ) (Long-time overload protection) Im= Ir (Short-circuit protection) 3.5 CM5 53UE: LV distribution networkd protection for CM5-400/ Overload protection with adjustable threshold, as defined by IEC Short-circuit protection with adjustable threshold 3. Instantaneous short-circuit protection 4. Earth fault protection with adjustable threshold 5. Load indication : light at 90% of Ir setting threshold; Flashing more than Ir setting threshold 6. Fault indication LEDs indicates the type of fault that caused tripping Overload (LT protection) or abnormal component temperature (>Ir); Short-circuit (ST or instantaneous protection)( >Im); Earth fault (if earth fault protection option is present)(ig); Microprocessor malfunction (both (>Ir) and ( >Im) LEDs go on,plus the (Ig) LEDs if earth fault protection option is present ) Battery powered. Spare battery are supplied in an adapter box. When a fault occurs, the LED indicating the type of fault, lights for about 10 minutes. The information is however stored in memory. The LED can be illuminated by pressing the test pushbutton. The LED automatically goes off and the memory is cleared when the circuit breaker is reset. 10

11 Cat. No. Rated Current In (A) Note CM CM CM5 43ME: motor protection for CM5-400/630 Ir=0.4~1 In(adjustable 48 setting) Tripping between 1.05~1.3 Ir (IEC ) at 6 Ir Trip time: 1s, 2s, 4s, 8s, 16s(adjustable) (Long-time overload protection) Isd= Ir Trip time: 0s, 0.1s, 0.2s, 0.3s adjustable+i2t (Short-circuit short time delay protection) Ii= Ir (Instantaneous short-circuit protection) Ig= Ir Trip time: 0.1s, 0.2s, 0.3s, 0.4s adjustable+i2t (Earth fault protection) (If option is present) 1. Overload protection with adjustable threshold, as defined by IEC (2) tripping class 10A,10 and Short-circuit protection with adjustable threshold (6...13xIr) 3. Phase failure protection (built-in electronic release: operates unbalanced single-phase currentat 40% and more than), as defined by IEC Load indication : Flashing more than Ir setting threshold 5. Fault indication LEDs indicates the type of fault that caused tripping Overload (LT protection) or abnormal component temperature (>Ir); Short-circuit (ST or instantaneous protection)( >Im); Phase failure (right LED); Microprocessor malfunction ( (>Ir) ( >Im) and phase failure LEDs all go on ) Battery powered. Spare battery are supplied in an adapter box. When a fault occurs,the LEDindicating the type of fault, lights for about 10 minutes. The information is however stored inmemory. The LED can be illuminated by pressing the test pushbutton. The LED automaticallygoes off and the memory is cleared when the circuit breaker is reset. Cat. No. Rated Current In (A) Note CM CM Ir=0.4~1 In(adjustable 48 setting) Trip degree: class 10A, 10,20(IEC ) (Long-time overload protection) Im= Ir (Short-circuit protection) 4. Accessories Cat. No. Accessories Rated operating voltage CM5-100~630 Shunt release(mx) Under-voltagerelease(UN) 24V 100V 220/230V 380/400V 220/230V 380/400V Consumption Pick-up Seal-in <10VA <5VA <10VA <5VA 11

12 Cat. No. Accessories Rated operating voltage CM5-100~630 AC12 Consumption Auxiliary contact (OF) 380/400V 6 3 Alarm contact (AL) 380/400V Rotary Handle 4.1. Direct Rotary Handle Degree of protection: IP40 Function: 1) suitability for isolation 2) indication of three positions 0(off) I(on) and tripped 3) press push to trip button, can trip-free 4) visibility of and access to trip unit settings 5) the circuit breaker can be locked in the off position by one to three padlocks, diameter 5 to 8mm(not supplied) 4.2. Extended Rotary Handle Degree of protection: IP55 Function: 1) Suitability for isolation 2) Indication of three positions 0(off) I(on) and tripped 3) Visibility of and access to trip unit settings when the door is open 4) Door opening prevented when circuit breaker is on 5) The circuit breaker can be locked in the off position by one to three padlocks, diameter 5 to 8mm(not supplied). Locking prevents opening of the switchboard door 5. Installation Circuit breaker may be mounted vertically, horizontally or flat on their back without any derating of characteristics. 6. Mounting Mounting on backplate, mounting on rails 7. Connection Front panel connection, black panel connection, plug-in connection. 8. Outline and Installtion Dimension AC15 12

13 Dimensions, mm C C1 C2 C3 G G1 G4 G5 H H1 H2 CM5-100/160/250N/H/L CM5-400/630N/H/L Dimensions, mm H3 H4 H5 H6 H7 K K1 K2 L L1 L2 P1 P2 P4 P5 CM5-100/160/250N/H/L * 83 CM5-400/630/N/H/L Dimensions, mm P6 R R1 R2 R4 R5 φt φt4 (Ue) CM5-100/160/250N/H/L CM5-400/630N/H/L *: P4=126 is suitable for CM5-250N/H/L 13

14 Cat. No. CM6 1. Applications CM6 series moulded case circuit breaker, it is suitable for the circuit of AC 50Hz(or60Hz), rated insulation Voltage 660V, rated operating Voltage under AC 660V, 250V(DC), rated operating current 10A-800A. It is for distribute energy of electricity and infrequent making and circuit, in normal conditions. The rated current under 400A they are provided with the function of the protection against overload and short circuit and under voltage. The comply with standard of IEC Technical Specificatioins CM P CM P Cat. No. CM P CM P Breaking capacity B N S B N S H X Rated current of frame size Inm Rated current In 10, 12.5, 16, 20, 25, 32, 40, 50, 63, 80, 100, , 16, 20, 25, (30), 32, 40, 50, (60), 63, 80, 100, 125, (150), , 16, 20, 25, 32, 40, 50, 63, 80, 100, (125) Rated insulation voltage Ui 500V 690V Rated operating voltage Ue 400V 400V Number of poles 3 3 Rated ultimate short-circuit breaking capacity Icu 400V/50HZ O-CO Rated service short-circuit breaking capacity Ics 400V/50HZ O-CO-CO Rated short-circuit making capacity Icm 400V/50HZ O-CO /0.3 74/ / /0.3 4/ / / Rated impulse withstand voltage Uimp ( V ) Dielectric property ( V ) Endurance Total cycles Electrical endurance Mechanical endurance Ionization distance ( mm ) 30/0 30/0 Over current trip unit Utilization category Outline dimensions Thermal magnetic release Intelligent trip unit -- Main circuit Auxiliary circuit W ( mm ) L ( mm ) H ( mm ) 70/ A AC-15 CM P CM P CM P CM P CM P is also available if need 14

15 Cat. No. CM P CM P Breaking capacity N S H G X N S H G X Rated current of frame size Inm 250 (315) 400 Rated current In 125, 160 ( 180 ), 200 ( 225 ), 250 ( 315 ) 250, 315 ( 350 ), 400 Rated insulation voltage Ui 690V 690V Rated operating voltage Ue 400V 400V Number of poles 3 3 Rated breaking capacity Icu 400V/50HZ O-CO Rated service short-circuit breaking capacity Ics 400V/50HZ O-CO-CO Rated breaking capacity Icm 400V/50HZ O-CO 74/ / / / / / / / Rated impulse withstand voltage Uimp ( V ) Dielectric property ( V ) Endurance Total cycles Electrical endurance Mechanical endurance Ionization distance ( mm ) 30/0 60/0 Over current trip unit Utilization category Outline dimensions Thermal magnetic release Intelligent trip unit Main circuit Auxiliary circuit W ( mm ) L ( mm ) 170: Thermal adjustable 217: Smart, Thermal, Magnetic adjustable 254: Smart, Thermal, Magnetic adjustable A/B AC : Thermal adjustable 339: Smart, Thermal, Magnetic adjustable H ( mm ) Cat. No. CM P CM P Breaking capacity N S H G X N S H G X Rated current of frame size Inm Rated current In 250, 315 ( 350 ), 400, 500, , 500, 630 ( 700 ), 800 Rated insulation voltage Ui 690V 690V Rated operating voltage Ue 400V 400V Number of poles 3 3 Rated breaking capacity Icu 400V/50HZ O-CO Rated service short-circuit breaking capacity Ics 400V/50HZ O-CO-CO Rated capacity Icm 400V/50HZ O-CO 74/ / / / / / / / Rated impulse withstand current (KA) Rated impulse withstand voltage Uimp ( V ) Dielectric property ( V ) Endurance Total cycles Electrical endurance Mechanical endurance Ionization distance ( mm ) 60/0 80/0 Over current trip unit Utilization category Outline dimensions Thermal magnetic release Intelligent trip unit Main circuit Auxiliary circuit W ( mm ) L ( mm ) H ( mm ) A/B AC-15 15

16 16 CM P CM P CM P CM P Cat. No. CM P CM P Breaking capacity S H G B N Rated current of frame size Inm Rated current In 800,1000,1250, ,16,20,25,32,40,50,63,80,100,125,160,200 Rated insulation voltage Ui 690V 500V Rated operating voltage Ue 400V 400V Number of poles 3 2 Rated breaking capacity Icu 400V/50HZ O-CO Rated service short-circuit breaking capacity Ics 400V/50HZ O-CO-CO Rated capacity Icm 400V/50HZ O-CO 105/ / / / /0.25 Rated impulse withstand current (KA) Rated impulse withstand voltage Uimp ( V ) Dielectric property ( V ) Endurance Total cycles Electrical endurance Mechanical endurance Ionization distance ( mm ) 80/0 30/0 Over current trip unit Utilization category Outline dimensions Thermal magnetic release Intelligent trip unit -- Main circuit B A Auxiliary circuit AC-15 AC-15 W ( mm ) L ( mm ) H ( mm ) Cat. No. CM P CM P Breaking capacity B N S B N S H Rated current of frame size Inm Rated current In 10, 12.5, 16, 20, 25, (30), 32, 40, 50, (60), 63, 80, 100, ,16,20,25, (30), 32, 40, 50, (60), 63, 80, 100, 125, (150), 160 Rated insulation voltage Ui 500V 690V Rated operating voltage Ue 400V 400V Number of poles 4 4 Rated current of the N pole = In = In Rated breaking capacity Icu 400V/50HZ O-CO Rated service short-circuit breaking capacity Ics 400V/50HZ O-CO-CO Rated capacity Icm 400V/50HZ O-CO 40/0.3 74/ / /0.3 74/ / /0.25 Rated impulse withstand voltage Uimp ( V ) Dielectric property ( V ) Endurance Total cycles Electrical endurance Mechanical endurance Ionization distance ( mm ) 30/0 30/0 Over current trip unit Utilization category Outline dimensions Thermal magnetic release Intelligent trip unit Main circuit A A Auxiliary circuit AC-15 AC-15 W ( mm ) L ( mm ) H ( mm ) 70/82 70/82

17 CM P CM6-125~160 Handle Cat. No. CM P Breaking capacity N S H G X Rated current of frame size Inm 800 Rated current In 400, 500, 630 ( 700 ), 800 Rated insulation voltage Ui 690V Rated operating voltage Ue 400V Number of poles 4 Rated breaking capacity Icu 400V/50HZ O-CO Rated service short-circuit breaking capacity Ics 400V/50HZ O-CO-CO Rated capacity Icm 400V/50HZ O-CO 74/ / / / Rated impulse withstand current (KA) 10 Rated impulse withstand voltage Uimp ( V ) 8000 Dielectric property ( V ) 3000 Endurance Total cycles 5000 Electrical endurance 1000 Mechanical endurance 4000 Ionization distance ( mm ) 80/0 Over current trip unit Utilization category Outline dimensions Thermal magnetic release Intelligent trip unit Main circuit Auxiliary circuit A/B AC-15 W ( mm ) L ( mm ) H ( mm ) CM6-250~400 Handle CM p Plug-in behind board CM P Plug-in in front of board CM6-800~1600 Handle CM P Drawer-type behind board CM P Drawer-type in front of board 17

18 Cat. No. CM6L 1. Applications CM6L series moulded earth leakage circuit breaker, it is suitable for the circuit of AC 50Hz (or 60Hz), rated insulation Voltage 660V, rated operating Voltage under AC 660V, 250V(DC), rated operating current 10A-800A. It is for distribute energy of electricity and infrequent making and circuit, in normal conditions. The rated current under 400A they are provided with the function of the protection against overload and short circuit and under voltage. The comply with standard of IEC Technical Specificatioins CM6L-125-4P CM6L-160-4P Cat. No. CM6L-125-4P CM6L-160-4P Breaking capacity B N S B N S Rated current of frame size Inm Rated current In 10, 12.5, 16, 20, 25, 32, 40, 50, 63, 80, 100, , 16, 20, 25, (30), 32, 40, 50, (60), 63, 80, 100, 125, (150), 160 Rated insulation voltage Ui 500V 690V Rated operating voltage Ue 400V 400V Number of poles 4 4 Rated current of the N pole = In = In Rated ultimate short-circuit breaking capacity Icu 400V/50HZ O-CO Rated service short-circuit breaking capacity Ics 400V/50HZ O-CO-CO Rated short-circuit making capacity Icm 400V/50HZ O-CO Rated remnant current short-circuit making capacity ( I M ) KA/cos Rated current remnant of motion I n ( ma ) Rated current remnant of no-motion I no ( ma ) Rated current remnant motion adjustable scope ( ma ) /0.3 74/ / /0.3 74/ /0.25 9/0.5 19/ Maximum cutting time adjustable scope, (ms) Limit no-motion time, (ms) Rated impulse withstand voltage Uimp ( V ) Dielectric property ( V ) Endurance Total cycles Electrical endurance Mechanical endurance Ionization distance ( mm ) 30/0 30/0 Over current trip unit Utilization category Outline dimensions Thermal magnetic release Intelligent trip unit -- Main circuit Auxiliary circuit A AC-15 W ( mm ) L ( mm ) H ( mm )

19 CM6L-125-4P CM6L-160-4P Cat. No. CM6L-250-4P CM6L-400-4P Breaking capacity N S H N S H Rated current of frame size Inm (400) Rated current In 125, 160, 200, , 315, 400, 500 Rated insulation voltage Ui 690V 690V Rated operating voltage Ue 400V 400V Number of poles 4 4 Rated current of the N pole = In = In Rated ultimate short-circuit breaking capacity Icu 400V/50HZ O-CO Rated service short-circuit breaking capacity Ics 400V/50HZ O-CO-CO Rated short-circuit making capacity Icm 400V/50HZ O-CO Rated remnant current short-circuit making capacity ( I M ) KA/cos Rated current remnant of motion I n ( ma ) Rated current remnant of no-motion I no ( ma ) Rated current remnant motion adjustable scope ( ma ) / / / / / /0.2 12/0.3 19/ Maximum cutting time adjustable scope, (ms) Limit no-motion time, (ms) Rated impulse withstand voltage Uimp ( V ) Dielectric property ( V ) Endurance Total cycles Electrical endurance Mechanical endurance Ionization distance ( mm ) 30/0 30/0 Over current trip unit Utilization category Outline dimensions Thermal magnetic release Intelligent trip unit -- Main circuit Auxiliary circuit A AC-15 W ( mm ) L ( mm ) H ( mm )

20 Cat. No. CM7 CM7 is suitable to be used in circuit of rated voltage up to AC 660V 50/60Hz, rated current from 0.1A to 63A, It is applicable for protection of overload & short circuit of 3 phase squirrel-cage motors. It also can be used as direct starter to start the motor and a switch for changeover the circuit under normal conditions. Specifications CM7-25 Current setting range(a) CM7-25 Power of controlled motor(kw) / / / / / /4 4/ Current rated(a) Current setting range(a) CM7-63 Power of controlled motor(kw) 0.37/ / /4 5.5/ Current rated(a) CM7-63 Cat. No. CM8 CM8 Motor protection circuit breaker CM8 is suitable in AC circuit of 50Hz or 60Hz, voltage up to 660V and current up to A and used to prevent small capacity motor and circuits from overload and short circuit and also used as direct starter for starting the motor and a switch for changeover the circuit under normal conditions. Specifications CM8-20 CM8-32 Type Poles Rated current(a) Rated voltage(v) Rated insulation voltage(v) Current setting range(a) Power of controlled motor (KW) Mechanical life(1*10 4 ) Protective feature 220V 380V 660V 1.05le 1.2le 12le CM ~ ~ ~ ~ ~1.1~ ~2.5 2~ ~4 3.2~5 4~6.3 5~8 6.3~10 8~ ~16 14~ CM ~ ~ ~4 4~ ~10 8~ ~ ~20 16~25 22~ Not act within 2hrs Act within 2hrs Action snap CM ~10 10~16 16~25 22~32 28~40 36~50 45~63 45~

21 Cat. No. CM9 CM9 series motor protection circuit breaker are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Type Current(A) Type Current(A) Type Current(A) CM9-M01c CM9-RS01c CM9-M02c CM9-RS02c CM9-M03c CM9-RS03c CM9-LS CM9-M04c CM9RS04c CM9-LS CM9-M05c CM9-RS05c CM9-LS CM9-M06c CM9-RS06c CM9-LS CM9-M07c CM9-RS07c CM9-LS CM9-M08c CM9-RS08c CM9-LS CM9-M10c CM9-RS10c CM9-LS CM9-M14c 6-10 CM9-RS14c 6-10 CM9-LS CM9-M16c 9-14 CM9-RS16c 9-14 CM9-LS CM9-M20c CM9-RS20c CM9-LS CM9-M21c CM9-RS21c CM9-M22c CM9-RS22c CM9-LS22c CM9-M32c CM9-RS32c CM9-LS32c

KM1 Series Moulded Case Circuit Breaker

KM1 Series Moulded Case Circuit Breaker KM1 KM1 Series Moulded Case Circuit Breaker 1. Application KM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied

More information

President of ANDELI Mr. Anlin Cheng (the third one) and deputy premier of the State Council Wu Yi

President of ANDELI Mr. Anlin Cheng (the third one) and deputy premier of the State Council Wu Yi About Andeli Andeli Group Co.,Ltd, founded in 199, is located in the largest manufacturing base of low-voltage electric equipment of Liushi China, which is called "the Electric Device Metropolis of China".

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Thermal magnetic and trip-free switches

Thermal magnetic and trip-free switches 87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue Low voltage Masterpact NT and NW LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type Catalogue 2015 Functions and characteristics Circuit breakers and switch-disconnectors NT06

More information

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB)

CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB) CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker 02 Part II Molded Case Circuit Breaker(MCCB) 07 UEM5 series Molded Case Circuit Breakers 08 UEM5L series

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

CHINT. NM7 Moulded Case Circuit Breaker

CHINT. NM7 Moulded Case Circuit Breaker CHINT Moulded Case Circuit Breaker Moulded Case Circuit Breaker Application Product introduction Functions and characteristics Accessories Overall and dimension Specification selection and order Page

More information

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V. Function CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit

More information

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection

More information

DRX 100 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL

More information

NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.

NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD. Shanghai Liangxin Electrical CO., LTD. - Liangxin Electrical - All rights reserved Address: No. 66 eng An Road, Pu Dong New District, Shanghai Post code: 07 Tel: 6--479 Fax: 6--5675966 E-mail: client@sh-liangxin.com

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Moulded Case Circuit Breaker

Moulded Case Circuit Breaker www.ckelectrical.com NS Series NS moulded case circuit breaker is one of the most advanced type breakers in the world, which adopts international advanced design and manufacturing technology. They are

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

Compact Merlin Gerin 80 to 3200 A

Compact Merlin Gerin 80 to 3200 A LV power air circuit breakers and switch-disconnectors Catalogue Compact Merlin Gerin 80 to 3200 A 2005 Industries SA 5, rue Nadar 92506 Rueil-Malmaison Cedex France Tel : +33 (0)1 41 29 82 00 Fax : +33

More information

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A Quality For You. How simple and functional can a range of moulded-case circuit-breakers be? It was answering this question, which

More information

MM5 Series High Breaking Mini Circuit Breakers

MM5 Series High Breaking Mini Circuit Breakers MM5 Series High reaking Mini ircuit reakers M Series A Series M Series ATS Series Load-isolating Series ontrol Appliance Series Product overview MM5 mini circuit breaker has novel structure, reliable performance,

More information

Moulded Case Circuit Breaker

Moulded Case Circuit Breaker 1 Body 2 Plugin bottom base 3 Residual current protecting module 4 Electrical operating module 5 External wiring board 6 Shunt tripe 7 Undervoltage trip 8 Auxiliary contact 9 Alarm contact 10 Rotatory

More information

(p. 47) (p. 155) (p. 155)

(p. 47) (p. 155) (p. 155) 0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

ELECTRIC PRODUCT CATALOGUE

ELECTRIC PRODUCT CATALOGUE ELECTRIC PRODUCT CATALOGUE!"#$%&' www.cetelec.com.cn SHANGHAI CET ELECTRIC CO. LTD. is one of the leading and the most reliable manufacturers and exporters for low voltage and high voltage electric products

More information

Motor Protection Circuit Breakers

Motor Protection Circuit Breakers Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

Breaking and protection devices

Breaking and protection devices Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

Power protection solutions

Power protection solutions Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and

More information

WORKSHOP SPECIFICATIONS

WORKSHOP SPECIFICATIONS WORKSHOP SPECIFICATIONS DPX 3 160 & 250 MOULDED CASE CIRCUIT BREAKERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DPX 3 RANGE Not only do DPX³ 160 and DPX 3 250 MCCBs provide

More information

Technical Data Accessories MCBs Ex9B.

Technical Data Accessories MCBs Ex9B. Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Industrial contactors CTX-1

Industrial contactors CTX-1 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical

More information

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager The RX 3 and DX-E ranges provide essential functions for the protection requirements of people and property in residential and small commercial buildings Two breaking capacities, 4500 and 6000 (IEC 60898-1)

More information

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric. K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch Features (1) All models fully comply with IEC regulations (2) Units can be mounted on a standard 35mm IEC rail (3) Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable

More information

MCCB Accessories to suit AF

MCCB Accessories to suit AF MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal

More information

UEW5 series intelligent air circuit breaker

UEW5 series intelligent air circuit breaker UEW5 series intelligent air circuit breaker UEW5 series intelligent air circuit breakers are applicable to the power distribution circuit under the condition of AC50Hz/60Hz, rated working voltage 400V

More information

INTELLIGENT AIR CIRCUIT BREAKER

INTELLIGENT AIR CIRCUIT BREAKER UEW5 SERIES INTELLIGENT AIR CIRCUIT BREAKER UEW5 Series intelligent Air Circuit Breaker(ACB) is applicable for the power distribution circuit under the condition of AC50HZ, rated working voltage 400V or

More information

Industrial Protection Products Edition

Industrial Protection Products Edition Industrial Protection Products 2016 Edition COMPANY PROFILE Shanghai Liangxin Electrical Co., LTD. one of the leading low-voltage electrical component manufacture in the high-end market, was established

More information

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144

More information

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS 87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

C60H-DC C curve. Catalogue numbers

C60H-DC C curve. Catalogue numbers distriution systems PB104013-34 The supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewale energy...). They comine the following functions

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A.

SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A. SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A. New SACE Tmax XT. Simply XTraordinary. ABB SACE is proud to present you the result of a long and intense research and development

More information

Compact NR630. NR100F to NR630F

Compact NR630. NR100F to NR630F Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS

More information

atalog Welcome to ATO.com! Contact us... Tel: (Toll-free) Website:

atalog Welcome to ATO.com! Contact us...   Tel: (Toll-free) Website: atalog Welcome to.com! Contact us... Email: sales@ato.com Tel: +1 800-585-1519 (Toll-free) Website: ZMQ2E Series Dual Power Automatic Transfer Switch (ATS) Applications ZMQ2E dual auto transfer switch

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. . 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

Technical catalogue - Preliminary. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A

Technical catalogue - Preliminary. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A Technical catalogue - Preliminary SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A Construction Characteristics 1 The SACE Tmax XT Ranges 2 Accessories 3 Characteristic Curves and

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650515200 Ed.1 of 21/02/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and

More information

COMPLETE SOLUTIONS FOR POWER PROTECTION

COMPLETE SOLUTIONS FOR POWER PROTECTION COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX

More information

Breakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary

Breakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary Breakers and Switches Tmax XT Moulded-case circuit-breakers Simply extraordinary Tmax XT Simply extraordinary ABB is proud to present you the result of a long and intense research and development project:

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Cat N 3. OVERALL DIMENSIONS

Cat N 3. OVERALL DIMENSIONS Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1

More information

ACS motor protection circuit breakers KT 7 Introduction

ACS motor protection circuit breakers KT 7 Introduction Introduction Automatic Type 2 coordination The right circuit breaker for all applications The KT 7 circuit breaker family consists of two basic frame sizes of mm and 5 mm in three variations with different

More information