MM5 Series High Breaking Mini Circuit Breakers
|
|
- Esther Kennedy
- 5 years ago
- Views:
Transcription
1 MM5 Series High reaking Mini ircuit reakers M Series A Series M Series ATS Series Load-isolating Series ontrol Appliance Series Product overview MM5 mini circuit breaker has novel structure, reliable performance, high breaking capability, pleasing outlook and small size, its case and items are adopted by high fire-resistant an shockproof plastics. It mainly used in the building office, house and similar building for illumination at A 50Hz/60Hz, rated voltage below V, rated 6A-63A. It is used in the distribution circuit and equipment overload, short circuit protection. It can be used for unfrequent switch over of the circuit under conditions. This product conforms to the requirement of IE & G standards. External accessory: alarm, auxiliary, shunt+ auxiliary, under voltage, overload voltage Function: overload, short circuit, earth leakage protection Usage: used for distributing and protecting motorreaking capacity: 4500, urrent: Number of poles: poles Standards: comply with IE 60898, G G Type and meanings M M 5-63 Features reaking capability (A) Type (poles) Voltage (V) reaking capability (A) 1~40 1~40 50~63 50~63 Release action characteristics Time delay Instantaneous frame esign code High breaking mini circuit breaking Zhejing MKM Electric O.,LT MM5-63 G10963, IE898, S P 2P 3P 4P 1P 2P 3P 4P 1.13In 1h non-trip 1.45In<1h trip 230/ In 1~120s trip (>32A)1~60s Release 1 32A ( type:5in < 0.1s non-trip): ( type:10in <0.1s non-trip) ( type:10in < 0.1s trip);( type:20in <0.1s trip) Protection features Protection features rated temperature voltage Electric life Mechanism life Hot and humid test 30 A 230V/V MM5-63():( ) A MM5-63():( ) A times times 2 kinds (relative humid 95% in 55 ) Weight (g) 1P 102 2P 208 3P 308 4P / ZHEJIANG MKM ELETRI O.,LT.
2 Limit features MM5 series high breaking mini circuit breaker has the high limit capability, and reduce the losing mostly, because of the short circuit. Thermal/ electromagnetic release features: (comply with G /IE) Overall and installation dimension Overall and installation dimension diagram Load-isolating Series M Series A Series M Series ATS Series Installation guide dimension diagram ontrol Appliance Series
3 MM5LE Series High reaking Mini ircuit reakers M Series A Series M Series ATS Series Load-isolating Series ontrol Appliance Series Application MM5LE series leakage circuit breaker is suitable in the A circuit of 50Hz, rated voltage up to 415V, rated 6A 63A to protect against leakage, electric shock, overload and short circuit. Users can add the protective function of overload voltage if they need. This product is mainly used in lighting and electric motor distribution system. This product conforms to the requirement of G16917 standards. Type and meanings M M 5 LE - 63 Features Item Poles and wires voltage Un(V) frame Inm(A) In(A) Type leakage action I Δn(A) leakage non-action I Δno(A) reaking time(s) short make-break capability(a)(cos Φ=0.7) Mechanism and electric life (times) Release action features elay time Instantaneous MM5LE- /1N MM5LE- /2 MM5LE- /3 MM5LE- /3N MM5LE- /4 One poles and two lines Overall and installation dimension leakage action Neutral lines Number of poles frame Special derive code (electronic leakage action) esign code High breaking mini circuit breaking Zhejing MKM Electric O.,LT 220V Two poles and two lines Three poles and Three poles and Four poles and three lines four lines four lines 63A 220V/380V 6A/10A/16A/20A/25A/32A/40A/50A/63A 0.03A/0.05A/0.1A 1 2 I n 0.1A Times >20000 Times 1. 13In 1h Non- trip 1. 13In<1h Trip 2.55In 1~120sTrip(>32A)1~60s Release 1 32A 5In<0.1s Non-trip 10In<0.1s Trip Overall and installation dimension diagram Protection features Type Overall dimension A E F G MM5LE- 63/ MM5LE- 63/ MM5LE- 63/ MM5LE-63/ MM5LE-63/ / ZHEJIANG MKM ELETRI O.,LT.
4 Application MM5-100mini circuit breaker is mainly suitable for overload and short protection. It is especially used for illumination and distribution. It is of pleasing out-look, light weight, reliable performance, high breaking capacity, quick trip.etc. Its frame and parts adopt plastic of high inflammable resistance and shock resistance for long service life. It is mainly used for overload and short circuit protection within the circuit of A 50/60Hz, rated voltage of single pole up to 230V, two, three of four poles up to V. It can also be used for an unfrequent switchover of circuit and illumination under normal conditions. this products conform to the requirement of IE & G standards M Series Type and meanings M M Main technical parameter Ambient temperature 40±2-5~45 I/In 1.05() 1.30() 3.0() 8.0~12.0 () 10.0~14.0 () Test time, appointed result In 63A 1h no trip 1h trip Return time 3s Instantaneous release type frame esign code High breaking mini circuit breaking Zhejing MKM Electric O.,LT Main type: type mainly used for protecting illumination, Type mainly used for protecting motor. is 63, 80, 100A NO. of pole includes single pole, two, three, four pole. Inlaid installation (can mount on the installation track) working voltage and related rated short circuit breaking capcity as show on table 1. (A) Poles short circuit make-break capability voltage (V) In > 63A 2h no trip 2h trip Return time 5s I/In 1.0 ( ) 1.2 ( ) 7.2 ( ) <0.2s trip <0.2s trip Test time, appointed result In 100A >2h no trip 2h trip >2s Power factor 63/80/100 1/2/3/4 230/ 0.45~0 Tripping characteristic as shown on table 2 Test circuit expected Table 1 Table 2 Start state old state Hot state Hot state old state ontrol Appliance Series Load-isolating Series ATS Series M Series A Series Voltage endure rate: besides the humid hotness resistant, this breaker can endure 2500V. Mechanical and electrical life: the mechanical electrical life is 10000times, and electrical life is 1500 times. Humid hotness resistant:2 types (relative humidity is 95% at 55 ) onnection: using the connection terminal with clip, the section of fixed cable can up to 50mm² 此处似乎缺少一句
5 MM5LE Series High reaking Mini ircuit reakers M Series A Series M Series ATS Series Load-isolating Series ontrol Appliance Series Overall and mounting dimensions Overall and installation dimension diagram Installation guide dimension diagram 005/ ZHEJIANG MKM ELETRI O.,LT.
6 Application MM5LE-100 series breaker is suitable for the circuit line of A 50Hz, rated voltage is 230/V and rated 63A-100A, and provides the protective function of earth leakage, overload and short circuit. The function also can be added according to the demand of users, which is mainly used for protecting building illumination and distribution system. Type and meanings M Series M M 5 LE Main technical parameter Number of poles frame Special derive code (electronic leakage action) esign code High breaking mini circuit breaking Zhejing MKM Electric O.,LT A Series M Series voltage 1 P + N : P: P: P+N : P: frame 230/ / / / / 100 4P 3P 2P 1P Poles and wires 1+N N short makebreak capability reak capability leakage action leakage action time Notice: earth leakage action : 30MA, 50MA, 100MA, 200MA, 300MA Using the connecting terminal with clip can connect the hard cable 50mm² or below leakage non-action Release type ATS Series Load-isolating Series ontrol Appliance Series
7 SM65(LE) Series High reaking Mini ircuit reakers Application M Series A Series M Series ATS Series Load-isolating Series ontrol Appliance Series SM65(LE) leakage protective breaker, protective breaker is used in the single phase residence circuit of A 50Hz/60Hz, rated voltage 230V, used as electron shock protection. This type is used for industrial, commercial, building and housing and so on similar places. It can be used for unfrequent switch over of the circuit under conditions people to use. Main technical parameter frame Inm(A) Poles and wires /60 voltage Ue(V) 230/ 230/ 230/ 230/ In(A) 1/2/4 6/10/16 20/25/32 40/50/63 1/2/4 6/10/16 20/25/32 40/50/63 Series Testing Starting state Trip or no trip time limited Respected result Remark a b c d e 1.13In 1.45In 2.55In 3In 5In 10In 5In 10In 16In Frequency (Hz) old clean criticality On top of A item testing old clean criticality old clean criticality old clean criticality t 0.1s( 63A) t<0.1s( 63A) 1s< t<60s(in 32A) 1s< t<120s(in 32A) t 0.1s t>0.1s operation short breaking capacity Ics reaking (A) 7500 cos 0.7 No tripped No tripped 7500 Table 1 limit short breaking capacity Icu reaking (A) 0.7 Table 2 urrent rise to prescribed value steady in 5S. cos Note: cold clean criticality means without overload before testing, and proceeding in fiducial regulate temperature 007/ ZHEJIANG MKM ELETRI O.,LT.
8 Trip curve diagram Outline and installation dimension M Series ATS Series M Series A Series SM65LE series high breaking miniature leakage circuit breaker Application SM65LE series high breaking miniature leakage circuit breaker is assembled by leakage release and SM65 series M in factory or on scene. It is used in the single phase residence circuit of A 50Hz/60Hz, rated voltage 230V, used as electron shock protection. It can protect civil electron circuit from overload and short circuit this product has advantages of small volume, high breaking capacity aero, and live wire are cut off at the same time, also protecting person from electric shock when the live wire connected opposite. Standard: IE ,G Load-isolating Series ontrol Appliance Series Main technique parameter (Table 1 Table 2 Table 3) Frame rated Inm(A) Pole 1P+N 2P P 4P Frequency (Hz) Eated voltage Ue(V) 230 In(A) surplus operating IΔn(mA) surplus no operation IΔno(mA) surplus making and breaking capacity IΔm reaking (A)cos Table 1 short breaking capacity Icu reaking (A)cos
9 SM65(LE) Series High reaking Mini ircuit reakers Table 2 M Series A Series M Series ATS Series Load-isolating Series ontrol Appliance Series (InA) Series a b c d e 1~63 Form Testing 1.13In 1.45In 2.55In 3In 5In 10In 5In 10In 16In I n 0.3 Starting state old clean criticality On top of A item testing old clean criticality old clean criticality old clean criticality Note: cold clean criticality means without overload before testing, and proceeding in fiducial regulate temperature Outline and installation dimension Residual equal to below value maximum breaking time. 2I n 0.15 Trip or no trip time limited t 0.1s( 63A) t<0.1s( 63A) 1s< t<60s(in 32A) 1s< t<120s(in 32A) t 0.1s t>0.1s 0.25A 0.04 Respected result No tripped No tripped 5I n 0.04 Remark urrent rise to prescribed value steady in 5S. Table 3 009/ ZHEJIANG MKM ELETRI O.,LT.
10 Application MG1-100 series miniature isolating switch is suitable for 50HZ, rated voltage V and below, rated up to 100A in distribution and control loop. It is used for main switch of terminal combination electrical switchgear, also can be used for non-frequent making and breaking. Application: istribution Pole number: 1/2/3/4P urrent: 32,63,100A Products comply with standards:ie G M Series Type and meaning Pole number Frame rated esign series Isolating switch Zhejiang MKM electric O.,LT A Series M Series onstruction features MG1-100 is composed of outside, operation mechanism and contact system. Operation mechanism and contact system is fixed joint, and have clear contact situation instruction. ON(RE) means contact closing situation, OFF(Green) means contact breaking situation ATS Series Main technique parameter working In(A) Pole number working voltage Ue(A) 32 63/ / Load-isolating Series life onnect and breaking capacity Electrify No electrify onnect and breaking capacity(a) I U Ie 1.05Ue 1692( Peak value)cosф In 1.05Ue 1692( Peak value)cosф0.95 ontrol Appliance Series short-time withstand Icw(A) Outline and installation dimension
cor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationDZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection
DZ47LE 1P+ DZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection DZ47LE C45LE RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationGE Consumer & Industrial. M-PACT New Air Circuit Breaker A
GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State
More informationNDM1 Series MCB Edition
NDM1 Series MCB 2016 Edition COMPANY PROFILE Shanghai Liangxin Electrical Co., LTD. one of the leading low-voltage electrical component manufacture in the high-end market, was established in 1999. Nader
More informationCONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB)
CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker 02 Part II Molded Case Circuit Breaker(MCCB) 07 UEM5 series Molded Case Circuit Breakers 08 UEM5L series
More informationC 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers
SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection
More informationCHINT. NM7 Moulded Case Circuit Breaker
CHINT Moulded Case Circuit Breaker Moulded Case Circuit Breaker Application Product introduction Functions and characteristics Accessories Overall and dimension Specification selection and order Page
More informationQUALITY ASSURANCE & DOCUMENTATION
QUALITY ASSURANCE & DOCUMENTATION RTECK IMPORTED PRODUCT STATEMENT Rteck has sourced most product from a large and reputable Chinese product manufacturer who specialise in the manufacture of modular electrical
More informationschneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.
K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles
More informationKM1 Series Moulded Case Circuit Breaker
KM1 KM1 Series Moulded Case Circuit Breaker 1. Application KM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied
More informationProtection components
Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More information- Moulded-case Circuit Breaker
Safety Protection Catalogue 2013/2014 - MAXTRIC circuit breaker Working with the world s electric specialist together @ Cat. No. CM1 1. Application CM1 series moulded case circuit breaker is one of products
More informationmax pole for t=15 ms
Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole
More informationSpecification for 70mm pole pitch Air circuit breaker up to 1600 A
Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with
More informationNDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.
Shanghai Liangxin Electrical CO., LTD. - Liangxin Electrical - All rights reserved Address: No. 66 eng An Road, Pu Dong New District, Shanghai Post code: 07 Tel: 6--479 Fax: 6--5675966 E-mail: client@sh-liangxin.com
More informationBasic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors
MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY
More informationInstantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch
Features (1) All models fully comply with IEC regulations (2) Units can be mounted on a standard 35mm IEC rail (3) Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable
More informationINTELLIGENT AIR CIRCUIT BREAKER
UEW5 SERIES INTELLIGENT AIR CIRCUIT BREAKER UEW5 Series intelligent Air Circuit Breaker(ACB) is applicable for the power distribution circuit under the condition of AC50HZ, rated working voltage 400V or
More informationDPX 1600 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationELECTRIC PRODUCT CATALOGUE
ELECTRIC PRODUCT CATALOGUE!"#$%&' www.cetelec.com.cn SHANGHAI CET ELECTRIC CO. LTD. is one of the leading and the most reliable manufacturers and exporters for low voltage and high voltage electric products
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationic60a circuit breakers (curve C)
(curve ) DB9 DB98 DB99 DB88 IE/EN 097- IE/EN 0898- ountry approval pictograms PB09-0 PB09-0 bb are multi-standard circuit breakers which combine the following functions: vvcircuit protection against short-circuit
More informationatalog Welcome to ATO.com! Contact us... Tel: (Toll-free) Website:
atalog Welcome to.com! Contact us... Email: sales@ato.com Tel: +1 800-585-1519 (Toll-free) Website: ZMQ2E Series Dual Power Automatic Transfer Switch (ATS) Applications ZMQ2E dual auto transfer switch
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More informationUEW5 series intelligent air circuit breaker
UEW5 series intelligent air circuit breaker UEW5 series intelligent air circuit breakers are applicable to the power distribution circuit under the condition of AC50Hz/60Hz, rated working voltage 400V
More informationType CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay
Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay DG 14 drawn out from the case The type DG 14 relay is a heavily damped
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationCircuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63
Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10
More informationDMX 3 -I 2500 switch disconnectors
8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40
More information020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)
020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service
More informationQF(13) - Series Miniature Circuit Breakers
DIN Mount 1 pole DIN Mount 2 pole Dual Mount 3 pole Dual Mount 3 + N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent of ambient temperature One, two, three, four
More informationCDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.
Function CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit
More informationMoulded case circuit breakers
Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded
More informationRCBOs - Residual current circuit breakers with integral overcurrent protection KZS
RCBOs - Residual current circuit breakers with integral overcurrent protection KZS Advantages of residual current circuit breakers with integral overcurrent protection KZS - 1M Combining the features of
More informationC60H-DC C curve. Catalogue numbers
distriution systems PB104013-34 The supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewale energy...). They comine the following functions
More informationMoulded Case Circuit Breaker
www.ckelectrical.com NS Series NS moulded case circuit breaker is one of the most advanced type breakers in the world, which adopts international advanced design and manufacturing technology. They are
More informationQF(19) - Series Miniature Circuit Breakers
Dual mount 1 pole Dual mount 2 pole Dual mount 3 pole Dual mount 3+N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent of ambient temperature One, two, three pole,
More informationEDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards
-P, -P and J-P (quipment Protection evice) ircuit reakers for round ault Protection in N Panelboards Square -P, -P and J-P (quipment Protection evice) ircuit reakers are 1-pole thermal-magnetic circuit
More informationDPX 630 Thermal magnetic and trip-free switches DPX-I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationDPX Electronic + earth leakage
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL
More informationF-Series. Circuit Breaker
F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic
More informationCat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090
More informationQF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A)
QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A) Dual Mount 1 pole Dual Mount 2 pole Dual Mount 3 + N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent
More informationCircuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories
Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks
More informationF-Series. Circuit Breaker
F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic
More informationMulti 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com
Multi 9 TM Catalogue 207 Multistandard protection for OEM schneider-electric.com Green Premium TM Endorsing industry eco-friendly products Schneider Electric s Green Premium ecolabel is committed to offering
More informationDPX 630 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationThermal magnetic and trip-free switches
87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/
More informationMotor Protection Circuit Breakers
Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions
More informationLEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1
More informationLow Voltage A GE Power Controls Company. General catalogue
Low Voltage A GE Power Controls Company General catalogue this is a blanc page Miniature circuit breakers A Miniature circuit breakers AC miniature circuit breakers Benefits of the new MCB s A 3 The AEG
More information87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS
87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationDRX 125 Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.
More informationMINIATURE CIRCUIT BREAKER
Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.
More informationDPX 160 Thermal magnetic and trip-free switches DPX-I 160
87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationIP20 degree of protection; IP40 degree of protection after installation in a distribution box
RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance
More informationDRX 250 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.
More informationCircuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...
Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal
More informationEKM1-63S MCB Mini Circuit Breaker
EKM1-63S MCB Mini Circuit Breaker Standard: IEC60898-1 Rated current In :1,,3,4,6,10,13,16,0,5,3,40,,63A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz
More informationand other modular devices for low voltage installation
Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories
More informationSoftstarter Intelligent Controllers
Softstarter Intelligent Controllers Series Modes of Operation (Standard) Soft Start 100% Percent Voltage Initial Torque Start Run This method has the most general application. The motor is raised from
More informationCharacteristics of LV circuit breakers Releases, tripping curves, and limitation
Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break
More informationElectronic circuit breaker EBU10-T
Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions
More informationIndustrial Protection Products Edition
Industrial Protection Products 2016 Edition COMPANY PROFILE Shanghai Liangxin Electrical Co., LTD. one of the leading low-voltage electrical component manufacture in the high-end market, was established
More informationHGM501 Gen-set Controller USER MANUAL. Smartgen Technology
HGM501 Gen-set Controller USER MANUAL Smartgen Technology Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. OVERVIEW... 4 PERFORMANCE AND CHARACTERISTICS... 4 TECHNICAL DATA... 5 OPERATION... 6 4.1. BUTTON DESCRIPTION...
More informationNew DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE
New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with
More informationic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi
Contents Miniature circuit breakers ic60n miniature circuit breakers 6kA, C curve, 6-63A ic60h miniature circuit breakers 10kA, C curve, 6-63A ic60n miniature circuit breakers 6kA, B curve, 6-63A ic60h
More information01 Spectra Plus - Introduction
01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More information6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate
More informationDRX 100 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL
More informationNEW. Moulded Case Circuit Breakers New DU Series 20 A to 250 A
NEW Moulded Case Circuit Breakers New DU Series 0 A to 50 A About us Larsen & Toubro is a technology-driven USD 7 billion company that infuses engineering with imagination. The Company offers a wide range
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationEquipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module
transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short
More informationPower systems Protection course
Al-Balqa Applied University Power systems Protection course Department of Electrical Energy Engineering Dr.Audih 1 Part 3 Protective Devices Fuses & Circuit Breakers 2 Introduction: Fuse Is advice used
More informationTechnical Journal September 2012
Technical Journal September 2012 Earth leakage protection in polluted low voltage network In present day irrespective of the application be it in process industry or in IT industry, Pollution of electrical
More informationData Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M
Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M MS50T3L M2N200T3L na.noark-electric.com NOARK Ex9 Series - M Features Molded Case Circuit
More informationData Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ
Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - BNQ BNQD5T BNQD5 with Front Mounting Clips na.noark-electric.com NOARK Ex9 Series - BNQ Features The BNQ is compliant with UL/CSA/IEC standards
More informationIndustrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw
Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator
More informationTECHNICAL DESCRIPTION
DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650523200 Ed.1 of 23/07/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and
More informationCompact NR630. NR100F to NR630F
Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS
More informationME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage
Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144
More informationLow voltage moulded case circuit breaker EB2
Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation
More informationPD-Series Ground Fault Circuit Protection
PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized
More informationMiniature Circuit Breaker
Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the
More informationMINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS
MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY
More informationNB1 Miniature Circuit Breaker
P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide
More informationJtec 489 UL489 Branch Circuit Breaker
Jtec 489 UL489 Branch Circuit Breaker 10kA Miniature Circuit Breaker R The Jtec 489 range is UL 489 listed (File E255530). Available in trip curves Z (v. quick), B (quick), C (medium), K (motor) and D
More informationPerfection that Matters
Perfection that Matters Switchgear Range Catalogue 2017 Contents Power Series Distribution Boards Classique Distribution Boards Miniature Circuit Breaker Isolator Residual Current Circuit Breaker Residual
More informationThe University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6
The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 6 PROTECTIONS 1 FUNCTION OF ELECTRICAL PROTECTION SYSTEMS Problems:
More informationLow voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue
Low voltage Masterpact NT and NW LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type Catalogue 2015 Functions and characteristics Circuit breakers and switch-disconnectors NT06
More informationContents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...
Contents Acti 9 MCBs, RCCB ic60h circuit breakers (curve B, C, D)... pages / to /4 ic60h and ic60h RCB0 10, 30 and 100 ma.... pages /5 to /8 Vigi ic60 add-on residual current devices.... pages /9 to /1
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.