EKM1-63S MCB Mini Circuit Breaker
|
|
- Moris Anderson
- 5 years ago
- Views:
Transcription
1 EKM1-63S MCB Mini Circuit Breaker Standard: IEC Rated current In :1,,3,4,6,10,13,16,0,5,3,40,,63A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :4,0/6,000A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: B,C,D Mechanical life:8,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~+40 Storage temperature: -5 ~+70 Terminal connection type: Cable/Pin-type busbar Terminal size top/bottom for cable: 5mm -3AWG Terminal size top/bottom for busbar: 5mm -3AWG Tightening torque.0 N*m In-Ibs
2 EKM1-63 MCB Mini Circuit Breaker Standard: IEC Rated current In :1,,3,4,6,10,13,16,0,5,3,40,,63A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :6,000A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: B,C,D Electrical life:8,000 Cycles Mechanical life:0,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~ +40 Storage temperature : -5 ~ +70 Terminal connection type: Cable/U-type busbar/pin-type busbar Terminal size top/bottom for cable: 5mm -3AWG Terminal size top/bottom for busbar: 5mm -3AWG Tightening torque.0 N*m In-Ibs
3 EKM1-63H MCB Mini Circuit Breaker Standard: IEC Rated current In :1,,3,4,6,10,13,16,0,5,3,40,,63A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :10,000A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: B,C,D Electrical life:8,000 Cycles Mechanical life:0,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~ +40 Storage temperature : -5 ~ +70 Terminal connection type: Cable/U-type busbar/pin-type busbar Terminal size top/bottom for cable: 5mm -3AWG Terminal size top/bottom for busbar: 5mm -3AWG Tightening torque.0 N*m In-Ibs
4 EKM1-63DC MCB Mini Circuit Breaker Standard: IEC Rated current In :1,,3,4,6,10,16,0,5,3,40,,63A Poles:1P, P, 4P Rated voltage Ue:1P(V), P(0V), 4P(1,000V) Rated breaking capacity :6,000/10,000A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: C (7~10)In Mechanical life:0,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~+40 Storage temperature: -5 ~+70 Terminal connection type: Cable/U-type busbar/pin-type busbar Terminal size top/bottom for cable: 5mm -3AWG Terminal size top/bottom for busbar: 5mm -3AWG Tightening torque.0 N*m In-Ibs
5 EKM1-40N MCB Mini Circuit Breaker Standard: IEC Rated current In :6,10,16,0,5,3,40A Poles:1P+N Rated voltage Ue:30/40V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :6,000A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: B,C Mechanical life:8,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~+40 Storage temperature: -5 ~+70 Terminal size top/bottom for cable: 16mm Terminal size top/bottom for busbar:16mm Tightening torque 1. N*m
6 EKM1-15 MCB Mini Circuit Breaker Standard: IEC Rated current In :63,80,100,15A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :10,000A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: C,D Mechanical life:10,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): Storage temperature : -5 ~ +70 Terminal connection type: Pin-type busbar Terminal size top/bottom for cable: mm Terminal size top/bottom for busbar: mm Tightening torque.5 N*m 06
7 EKM1-OF EKM1-FB Auxiliary Contact for EKM1,EKL3 Alarm Auxiliary Contact for EKM1,EKL3 Standard: IEC Rated value: A C415 /400V /60Hz 3A A C40 /400V /60Hz 3A D C130V 1A D C48V A D C4V 6A Configurations: EKM1-OF 1N/O+1N/C EKM1-FB 1N/O+1N/C Rated impulse withstand voltage (1./)Uimp: 4,000V Rated short circuit making capacity: 0le, t=0.1s Dielectric test voltage at ind. Freq. for 1min: kv Insulation voltage Ui: 0V Pollution degree: EKM1-OF EKM1-OF Electrical life:6,000 Cycles Mechanical life:10,000 Cycles Protection degree: I P0 Ambient temperature (with daily average 35 ):-5 ~ +40 Storage temperature : -5 ~ +70 Terminal connection type: Cable Terminal size top/bottom for cable:.5mm -13AWG Tightening torque 0.8 N*m 7In-Ibs. EKM1-FB EKM1-FB
8 EKM1-MX EKM1-MN+MV Shunt Release Over/Under-voltage Tripper Standard: IEC EKM1-MX Rated voltage US(V): AC30/400 /60Hz DC4 DC48 A C4 /60Hz Rated impulse withstand voltage (1./)Uimp: 4,000V Rated short circuit making capacity: 0le, t=0.1s Dielectric test voltage at ind. Freq. for 1min: kv Insulation voltage Ui: 0V Pollution degree: EKM1-MN+MV Rated voltage (Ue): AC30V Rated insulating voltage(ui):0v Over-voltage tripping range:80v±5% Under-voltage tripping range:170v±5% Mounted on the right side of circuit breaker, actuate the combined device to trip in case of under-voltage or over-voltage, effectively prevent the device from closing operation under abnormal power voltage condition. EKM1-MX Mechanical life:4,000 Cycles Protection degree: I P0 Ambient temperature (with daily average 35 ):-5 ~ +40 Storage temperature : -5 ~ +70 Terminal connection type: Cable Terminal size top/bottom for cable:.5mm -13AWG Tightening torque 0.8 N*m 7In-Ibs. EKM1-MN+MV
9 DZ47-63 Economic MCB Mini Circuit Breaker Standard: IEC Rated current In :1,,3,4,6,10,16,0,5,3,40,,63A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :4,0A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: B,C,D Electrical life:4,000 Mechanical life:8,000 Contact position indicator: No Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~+40 Storage temperature: -5 ~+70 Terminal connection type: Cable/Pin-type busbar Terminal size top/bottom for cable: 5mm Terminal size top/bottom for busbar: 5mm Tightening torque.0 N*m 74.5 (1P=71.5) 15
10 DZ47-63 Economic MCB (New type) Mini Circuit Breaker Standard: IEC Rated current In :1,,3,4,6,10,16,0,5,3,40,,63A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :4,0A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: B,C,D Mechanical life:8,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~+40 Storage temperature: -5 ~+70 Terminal connection type: Cable/U-type busbar/pin-type busbar Terminal size top/bottom for cable: 5mm Terminal size top/bottom for busbar: 5mm Tightening torque.0 N*m
11 CAMH-15 Economic MCB Mini Circuit Breaker Standard: IEC Rated current In :63,80,100,15A Poles:1P, 1P+N,P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :6,000A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: C,D Mechanical life:10,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~+40 Storage temperature: -5 ~+70 Terminal connection type: Pin-type busbar Terminal size top/bottom for cable: mm Terminal size top/bottom for busbar: mm Tightening torque.5 N*m 17
12 Circuit Diagram EKM1 5 7 EKM1 (DC) Load 6 8 EKL EKL3 EKL4 EKL5 EKL1 9
13 MCB Characteristics Characteristics Curves Thermal Tripping Magnetic Tripping min As per IEC60898 No tripping current Tripping current Time Limits Hold current Trip current I t I 4 I 5 t Time Limits 1 T V [s] B Curve C Curve D Curve B Curve C Curve 1.13 I N 1.13 I N 1. I N 1. I N 1h <1h 1h <1h 3 I N 5 I N 5 I N 10 I N 0.1s <0.1s 0.1s <0.1s D Curve 1.13 I N 1h 10 I N 0.1s I N <1h 0 I N <0.1s I 3=.55 IN 1s<t<60s for IN<3A 1s<t<60s for IN<3A X I n 1 3 Tripping characteristics Based on the Tripping Characteristics, MCBs are available in B, C and D curve to suit different types of applications. B Curve for protection of electrical circuits with equipment that does not cause surge current (lighting and distribution circuits) Short circuit release is set to (3-5)In. C Curve for protection of electrical circuits with equipment that cause surge current (inductive loads and motor circuits) Short circuit release is set to (5-10)In. D Curve for protection of electrical circuits with cause high inrush current,typically 1-15 times the thermal rated current (transformes, x-ray machines etc,)short circuit release is set to (10-0)In. Current limiting design Voltage across contacts during opening of MCB Voltage 1.13In 1.In 0 Time Maximum Prospective Current A Cut-off Current Fault Current B 0 t x t 1 T 30
NB1 Miniature Circuit Breaker
P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide
More informationand other modular devices for low voltage installation
Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories
More informationThe effective choice The benefits of a product with the highest quality standards
The effective choice The benefits of a product with the highest quality standards Compact size for easy installation in small spaces and retrofitting of already existing facilities. Terminals designed
More informationABB STOTZ-KONTAKT GmbH
ABB STOTZ-KONTAKT GmbH MULTIPLE 89 Motijheel C/A, Lucky Chamber (3rd floor, Room #61), Dhaka-1000, Bangladesh. Tel: (02) 9559692, Fax: (02)9566596 E-mail: info@multipletrading.net PAGE : 02 The ABB Line
More informationW DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO
W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W SCHRACK-INFO Lift and clamp terminals on both sides Terminal guide for secure connection Terminal cross-section: 1-25mm² Snap-on mounting for
More informationThe breakers offer thermal-magnetic trip protection according to Z and K characteristics.
Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationschneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.
K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles
More informationCDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.
Function CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit
More information67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS
Technical data and compliance with Standards Component Interlocked switched socket-outlets SELV socket-outlet Rotary switch MT60 miniature circuit breaker, C characteristic, 6kA Reference Standards EN
More informationDRX 125 Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.
More informationDX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data
Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationDRX 100 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL
More informationCONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB)
CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker 02 Part II Molded Case Circuit Breaker(MCCB) 07 UEM5 series Molded Case Circuit Breakers 08 UEM5L series
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationDPX Magnetic only
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY
More informationRX 3 MCB 4500 A Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More information6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate
More informationCat N 3. OVERALL DIMENSIONS
Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1
More informationDX³ 4-pole RCBO 6000 A/10 ka
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationLEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1
More informationResidual current devices
Residual devices FH00 Plus of range /30 Technical features table /3 Ordering information /34 Technical details /37 DS01 and DS0C Plus of range /38 Technical features table /40 Ordering information DS01
More informationDRX 250 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.
More informationManual Motor Starters
Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC
More informationCTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationup to 63 A (1 module per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series
More informationCat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090
More informationThermal Overcurrent Circuit Breaker 3120-F...
Thermal Overcurrent Circuit Breaker -F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 694 with trip free mechanism) offering the choice of single
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationThermal-Magnetic Circuit Breaker 2210-S291-P9M A
Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationELFA E90S MINI BREAKERS
ELFA E90S MINI BREAKERS ELFA E90S SERIES UL Approved (UL1077) 10KA INTERUPTION CAPACITY OPTIONS FIELD KITS Auxiliary Contacts Alarm Contact Shunt Trip UV Trip Current Limiting Design (Class 3) 3 Different
More informationUMBW-UL489 and UL1077 Listed
-UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection
More informationRX 3 M.C.B A up to 63 A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationMiniature Circuit Breaker
Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the
More informationElectronic circuit breaker EBU10-T
Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions
More informationThermal-magnetic Miniature Circuit Breaker 4230-T...
Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail
More information(Miniature Circuit Breaker)
(Miniature Circuit Breaker) Features : l Uniform 10KA breaking capacity for B and C Curve l Low power consumption, thus cost effective & energy saving l Suitable for DC and for a wide frequency range of
More informationLow Voltage A GE Power Controls Company. General catalogue
Low Voltage A GE Power Controls Company General catalogue this is a blanc page Miniature circuit breakers A Miniature circuit breakers AC miniature circuit breakers Benefits of the new MCB s A 3 The AEG
More informationTechnical Data Accessories MCBs Ex9B.
Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationSystem pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489
Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationResidual Current Circuit-breaker (RCCB) FH 200 Series
Residual Current Circuit-breaker (RCCB) FH 200 Series Bi-directional cylindrical terminal ensure higher safety of connecting operations, making them easier. Test pushbutton to verify the correct functioning
More informationCharacteristics of LV circuit breakers Releases, tripping curves, and limitation
Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break
More informationSystem pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489
System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch
More informationDX³ RCBO 4500/6 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationSFS-UFS Single Foot Switches
SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes
More informationMINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS
MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationProtection components
Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed
More informationJtec 10kA Miniature Circuit Breaker
EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in
More informationMINIATURE CIRCUIT BREAKER
Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.
More informationTyp 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand
LV-SWITCHING DEVICES / NH-SCHALTGERÄTE 1 Vertical 415 design fuse rails TRIVER / NH-Sicherungsleisten TRIVER Range / Produktpalette Type 415 fuse rails BTVA/BTVA-P, NH 1/2/3, 2/400/, mm busbars spacing
More informationRX 3 M.C.B A up to 63 A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationic60a circuit breakers (curve C)
(curve ) DB9 DB98 DB99 DB88 IE/EN 097- IE/EN 0898- ountry approval pictograms PB09-0 PB09-0 bb are multi-standard circuit breakers which combine the following functions: vvcircuit protection against short-circuit
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V
Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics
More informationThermal Overcurrent Circuit Breaker 3120-F...
Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationLR9 F OVERLOAD RELAYS
Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.
More informationLimit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66
Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66
More informationThermal-Magnetic Circuit Breaker M1-...
Thermal-Magnetic Circuit Breaker 320-...-M-... Description Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 6034). The addition of a magnetic tripping
More informationDS201 - DS202C New residual current circuit-breakers with overcurrent protection (RCBOs)
DS201 - DS202C New residual circuit-breakers with over protection (RCBOs) New residual circuit-breakers with over protection (RCBOs) - DS201 - DS202C 1P+N and 2P in two modules. Complete protection To
More informationMV Air Insulated Switchgear TAP17. Technical Data TGOOD
MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)
More informationNDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.
Shanghai Liangxin Electrical CO., LTD. - Liangxin Electrical - All rights reserved Address: No. 66 eng An Road, Pu Dong New District, Shanghai Post code: 07 Tel: 6--479 Fax: 6--5675966 E-mail: client@sh-liangxin.com
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationSentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification
543 technical hotline +44 ()1268 56372 Standards and approvals Sentry MCBs are designed to fully comply with the relevant requirements of BS EN 6898: 23. They all feature positive contact status indication
More informationSystem pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077
Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with
More informationTMC 91H is now TMC 60 C Series
TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the
More informationDX³ RCBO 6000A Phase + Neutral, neutral on right
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationC60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V
DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More informationK50H004UP cam changeover switch - 4-pole A - screw mounting
Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationDSE201 Compact design with enhanced protection
DSE201 Compact design with enhanced protection The best of safety DSE201 6 ka: the highest level of reliability The 1P+N electronic residual current circuit-breakers with overcurrent protection (RCBOs)
More information70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX
70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency
More information1489-M Circuit Breakers
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More informationSystem pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications
Data Sheet System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System
More informationK30H001YP cam star-delta switch - 3-pole A - screw mounting
Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationDX³ RCBO 6000A Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationPerfection that Matters
Perfection that Matters Switchgear Range Catalogue 2017 Contents Power Series Distribution Boards Classique Distribution Boards Miniature Circuit Breaker Isolator Residual Current Circuit Breaker Residual
More informationSIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function
The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationSoftstarter Intelligent Controllers
Softstarter Intelligent Controllers Series Modes of Operation (Standard) Soft Start 100% Percent Voltage Initial Torque Start Run This method has the most general application. The motor is raised from
More informationT-Switches Range. TL Contactors TS disconnectors TP Contactors. TELARC s multipurpose DC and AC current switches for multiple application.
TP-PNORM T-Switches Range TL Contactors TS disconnectors TP Contactors TELRC s multipurpose DC and C current switches for multiple application Rolling Stock Energy generation Substation equipment Industrial
More informationMolded case circuit breakers
Molded case circuit breakers Metasol 30F to 250F Series Type Type and Pole Rated current, In Rated operational voltage, Ue Rated insulation voltage, Ui Rated impulse withstand voltage, Uimp Frame Size(F)
More informationProduct brochure. ABB Fusegear EasyLine Fuse switch disconnector
Product brochure ABB Fusegear EasyLine Fuse switch disconnector 2 EasyLine Fuse Switch Disconnector ABB Fusegear Content Fuse protection 4 Technical Data 5 General 6 Apparatus overview 7 Electronic Fuse
More informationSeries KTU7 UL489 Molded Case Circuit Breakers
Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed
More informationDX³ RCBO 6000 A Phase + Neutral, neutral right side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationwww. ElectricalPartManuals. com Miniature Circuit Breakers Section 7
EP60 Series...7-2 EP100 Series...7-4 EP100 ULH Series...7-6 EP100 UC Series (Branch Circuit Protection)...7-8 Series CA Auxiliary Switch and Bell Alarm...7-10 Series CB Auxiliary Switch and Bell Alarm...7-11
More informationKtec Contactors and thermal overloads
Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America
More informationBtdin-RS RCBO 2p Phase + Neutral, neutral on right
Viale Borri 231, 21100 Varese - Italy RCBO 2p CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1 5. General characteristics... 2 6. Compliance
More informationDX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 / 10 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationSeries KTU7 UL489 Molded Case Circuit Breakers
Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current
More information