EKM1-63S MCB Mini Circuit Breaker

Size: px
Start display at page:

Download "EKM1-63S MCB Mini Circuit Breaker"

Transcription

1 EKM1-63S MCB Mini Circuit Breaker Standard: IEC Rated current In :1,,3,4,6,10,13,16,0,5,3,40,,63A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :4,0/6,000A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: B,C,D Mechanical life:8,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~+40 Storage temperature: -5 ~+70 Terminal connection type: Cable/Pin-type busbar Terminal size top/bottom for cable: 5mm -3AWG Terminal size top/bottom for busbar: 5mm -3AWG Tightening torque.0 N*m In-Ibs

2 EKM1-63 MCB Mini Circuit Breaker Standard: IEC Rated current In :1,,3,4,6,10,13,16,0,5,3,40,,63A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :6,000A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: B,C,D Electrical life:8,000 Cycles Mechanical life:0,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~ +40 Storage temperature : -5 ~ +70 Terminal connection type: Cable/U-type busbar/pin-type busbar Terminal size top/bottom for cable: 5mm -3AWG Terminal size top/bottom for busbar: 5mm -3AWG Tightening torque.0 N*m In-Ibs

3 EKM1-63H MCB Mini Circuit Breaker Standard: IEC Rated current In :1,,3,4,6,10,13,16,0,5,3,40,,63A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :10,000A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: B,C,D Electrical life:8,000 Cycles Mechanical life:0,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~ +40 Storage temperature : -5 ~ +70 Terminal connection type: Cable/U-type busbar/pin-type busbar Terminal size top/bottom for cable: 5mm -3AWG Terminal size top/bottom for busbar: 5mm -3AWG Tightening torque.0 N*m In-Ibs

4 EKM1-63DC MCB Mini Circuit Breaker Standard: IEC Rated current In :1,,3,4,6,10,16,0,5,3,40,,63A Poles:1P, P, 4P Rated voltage Ue:1P(V), P(0V), 4P(1,000V) Rated breaking capacity :6,000/10,000A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: C (7~10)In Mechanical life:0,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~+40 Storage temperature: -5 ~+70 Terminal connection type: Cable/U-type busbar/pin-type busbar Terminal size top/bottom for cable: 5mm -3AWG Terminal size top/bottom for busbar: 5mm -3AWG Tightening torque.0 N*m In-Ibs

5 EKM1-40N MCB Mini Circuit Breaker Standard: IEC Rated current In :6,10,16,0,5,3,40A Poles:1P+N Rated voltage Ue:30/40V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :6,000A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: B,C Mechanical life:8,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~+40 Storage temperature: -5 ~+70 Terminal size top/bottom for cable: 16mm Terminal size top/bottom for busbar:16mm Tightening torque 1. N*m

6 EKM1-15 MCB Mini Circuit Breaker Standard: IEC Rated current In :63,80,100,15A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :10,000A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: C,D Mechanical life:10,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): Storage temperature : -5 ~ +70 Terminal connection type: Pin-type busbar Terminal size top/bottom for cable: mm Terminal size top/bottom for busbar: mm Tightening torque.5 N*m 06

7 EKM1-OF EKM1-FB Auxiliary Contact for EKM1,EKL3 Alarm Auxiliary Contact for EKM1,EKL3 Standard: IEC Rated value: A C415 /400V /60Hz 3A A C40 /400V /60Hz 3A D C130V 1A D C48V A D C4V 6A Configurations: EKM1-OF 1N/O+1N/C EKM1-FB 1N/O+1N/C Rated impulse withstand voltage (1./)Uimp: 4,000V Rated short circuit making capacity: 0le, t=0.1s Dielectric test voltage at ind. Freq. for 1min: kv Insulation voltage Ui: 0V Pollution degree: EKM1-OF EKM1-OF Electrical life:6,000 Cycles Mechanical life:10,000 Cycles Protection degree: I P0 Ambient temperature (with daily average 35 ):-5 ~ +40 Storage temperature : -5 ~ +70 Terminal connection type: Cable Terminal size top/bottom for cable:.5mm -13AWG Tightening torque 0.8 N*m 7In-Ibs. EKM1-FB EKM1-FB

8 EKM1-MX EKM1-MN+MV Shunt Release Over/Under-voltage Tripper Standard: IEC EKM1-MX Rated voltage US(V): AC30/400 /60Hz DC4 DC48 A C4 /60Hz Rated impulse withstand voltage (1./)Uimp: 4,000V Rated short circuit making capacity: 0le, t=0.1s Dielectric test voltage at ind. Freq. for 1min: kv Insulation voltage Ui: 0V Pollution degree: EKM1-MN+MV Rated voltage (Ue): AC30V Rated insulating voltage(ui):0v Over-voltage tripping range:80v±5% Under-voltage tripping range:170v±5% Mounted on the right side of circuit breaker, actuate the combined device to trip in case of under-voltage or over-voltage, effectively prevent the device from closing operation under abnormal power voltage condition. EKM1-MX Mechanical life:4,000 Cycles Protection degree: I P0 Ambient temperature (with daily average 35 ):-5 ~ +40 Storage temperature : -5 ~ +70 Terminal connection type: Cable Terminal size top/bottom for cable:.5mm -13AWG Tightening torque 0.8 N*m 7In-Ibs. EKM1-MN+MV

9 DZ47-63 Economic MCB Mini Circuit Breaker Standard: IEC Rated current In :1,,3,4,6,10,16,0,5,3,40,,63A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :4,0A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: B,C,D Electrical life:4,000 Mechanical life:8,000 Contact position indicator: No Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~+40 Storage temperature: -5 ~+70 Terminal connection type: Cable/Pin-type busbar Terminal size top/bottom for cable: 5mm Terminal size top/bottom for busbar: 5mm Tightening torque.0 N*m 74.5 (1P=71.5) 15

10 DZ47-63 Economic MCB (New type) Mini Circuit Breaker Standard: IEC Rated current In :1,,3,4,6,10,16,0,5,3,40,,63A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :4,0A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: B,C,D Mechanical life:8,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~+40 Storage temperature: -5 ~+70 Terminal connection type: Cable/U-type busbar/pin-type busbar Terminal size top/bottom for cable: 5mm Terminal size top/bottom for busbar: 5mm Tightening torque.0 N*m

11 CAMH-15 Economic MCB Mini Circuit Breaker Standard: IEC Rated current In :63,80,100,15A Poles:1P, 1P+N,P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz Rated breaking capacity :6,000A Rated impulse withstand voltage(1./) Uimp:4,000V Dielectric test voltage at ind. Freq. for 1 min:kv Pollution degree: Thermo-magnetic release characteristic: C,D Mechanical life:10,000 Cycles Protection degree:ip0 Ambient temperature (with daily average 35 ): -5 ~+40 Storage temperature: -5 ~+70 Terminal connection type: Pin-type busbar Terminal size top/bottom for cable: mm Terminal size top/bottom for busbar: mm Tightening torque.5 N*m 17

12 Circuit Diagram EKM1 5 7 EKM1 (DC) Load 6 8 EKL EKL3 EKL4 EKL5 EKL1 9

13 MCB Characteristics Characteristics Curves Thermal Tripping Magnetic Tripping min As per IEC60898 No tripping current Tripping current Time Limits Hold current Trip current I t I 4 I 5 t Time Limits 1 T V [s] B Curve C Curve D Curve B Curve C Curve 1.13 I N 1.13 I N 1. I N 1. I N 1h <1h 1h <1h 3 I N 5 I N 5 I N 10 I N 0.1s <0.1s 0.1s <0.1s D Curve 1.13 I N 1h 10 I N 0.1s I N <1h 0 I N <0.1s I 3=.55 IN 1s<t<60s for IN<3A 1s<t<60s for IN<3A X I n 1 3 Tripping characteristics Based on the Tripping Characteristics, MCBs are available in B, C and D curve to suit different types of applications. B Curve for protection of electrical circuits with equipment that does not cause surge current (lighting and distribution circuits) Short circuit release is set to (3-5)In. C Curve for protection of electrical circuits with equipment that cause surge current (inductive loads and motor circuits) Short circuit release is set to (5-10)In. D Curve for protection of electrical circuits with cause high inrush current,typically 1-15 times the thermal rated current (transformes, x-ray machines etc,)short circuit release is set to (10-0)In. Current limiting design Voltage across contacts during opening of MCB Voltage 1.13In 1.In 0 Time Maximum Prospective Current A Cut-off Current Fault Current B 0 t x t 1 T 30

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

The effective choice The benefits of a product with the highest quality standards

The effective choice The benefits of a product with the highest quality standards The effective choice The benefits of a product with the highest quality standards Compact size for easy installation in small spaces and retrofitting of already existing facilities. Terminals designed

More information

ABB STOTZ-KONTAKT GmbH

ABB STOTZ-KONTAKT GmbH ABB STOTZ-KONTAKT GmbH MULTIPLE 89 Motijheel C/A, Lucky Chamber (3rd floor, Room #61), Dhaka-1000, Bangladesh. Tel: (02) 9559692, Fax: (02)9566596 E-mail: info@multipletrading.net PAGE : 02 The ABB Line

More information

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W SCHRACK-INFO Lift and clamp terminals on both sides Terminal guide for secure connection Terminal cross-section: 1-25mm² Snap-on mounting for

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric. K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles

More information

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V. Function CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit

More information

67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS

67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS Technical data and compliance with Standards Component Interlocked switched socket-outlets SELV socket-outlet Rotary switch MT60 miniature circuit breaker, C characteristic, 6kA Reference Standards EN

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

DRX 100 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL

More information

CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB)

CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB) CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker 02 Part II Molded Case Circuit Breaker(MCCB) 07 UEM5 series Molded Case Circuit Breakers 08 UEM5L series

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

Cat N 3. OVERALL DIMENSIONS

Cat N 3. OVERALL DIMENSIONS Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

Residual current devices

Residual current devices Residual devices FH00 Plus of range /30 Technical features table /3 Ordering information /34 Technical details /37 DS01 and DS0C Plus of range /38 Technical features table /40 Ordering information DS01

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

Manual Motor Starters

Manual Motor Starters Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

up to 63 A (1 module per pole)

up to 63 A (1 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. . 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker -F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 694 with trip free mechanism) offering the choice of single

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

ELFA E90S MINI BREAKERS

ELFA E90S MINI BREAKERS ELFA E90S MINI BREAKERS ELFA E90S SERIES UL Approved (UL1077) 10KA INTERUPTION CAPACITY OPTIONS FIELD KITS Auxiliary Contacts Alarm Contact Shunt Trip UV Trip Current Limiting Design (Class 3) 3 Different

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

Electronic circuit breaker EBU10-T

Electronic circuit breaker EBU10-T Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

(Miniature Circuit Breaker)

(Miniature Circuit Breaker) (Miniature Circuit Breaker) Features : l Uniform 10KA breaking capacity for B and C Curve l Low power consumption, thus cost effective & energy saving l Suitable for DC and for a wide frequency range of

More information

Low Voltage A GE Power Controls Company. General catalogue

Low Voltage A GE Power Controls Company. General catalogue Low Voltage A GE Power Controls Company General catalogue this is a blanc page Miniature circuit breakers A Miniature circuit breakers AC miniature circuit breakers Benefits of the new MCB s A 3 The AEG

More information

Technical Data Accessories MCBs Ex9B.

Technical Data Accessories MCBs Ex9B. Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

Residual Current Circuit-breaker (RCCB) FH 200 Series

Residual Current Circuit-breaker (RCCB) FH 200 Series Residual Current Circuit-breaker (RCCB) FH 200 Series Bi-directional cylindrical terminal ensure higher safety of connecting operations, making them easier. Test pushbutton to verify the correct functioning

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

SFS-UFS Single Foot Switches

SFS-UFS Single Foot Switches SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand LV-SWITCHING DEVICES / NH-SCHALTGERÄTE 1 Vertical 415 design fuse rails TRIVER / NH-Sicherungsleisten TRIVER Range / Produktpalette Type 415 fuse rails BTVA/BTVA-P, NH 1/2/3, 2/400/, mm busbars spacing

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

ic60a circuit breakers (curve C)

ic60a circuit breakers (curve C) (curve ) DB9 DB98 DB99 DB88 IE/EN 097- IE/EN 0898- ountry approval pictograms PB09-0 PB09-0 bb are multi-standard circuit breakers which combine the following functions: vvcircuit protection against short-circuit

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

LR9 F OVERLOAD RELAYS

LR9 F OVERLOAD RELAYS Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.

More information

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66

More information

Thermal-Magnetic Circuit Breaker M1-...

Thermal-Magnetic Circuit Breaker M1-... Thermal-Magnetic Circuit Breaker 320-...-M-... Description Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 6034). The addition of a magnetic tripping

More information

DS201 - DS202C New residual current circuit-breakers with overcurrent protection (RCBOs)

DS201 - DS202C New residual current circuit-breakers with overcurrent protection (RCBOs) DS201 - DS202C New residual circuit-breakers with over protection (RCBOs) New residual circuit-breakers with over protection (RCBOs) - DS201 - DS202C 1P+N and 2P in two modules. Complete protection To

More information

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

MV Air Insulated Switchgear TAP17. Technical Data TGOOD MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)

More information

NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.

NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD. Shanghai Liangxin Electrical CO., LTD. - Liangxin Electrical - All rights reserved Address: No. 66 eng An Road, Pu Dong New District, Shanghai Post code: 07 Tel: 6--479 Fax: 6--5675966 E-mail: client@sh-liangxin.com

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification 543 technical hotline +44 ()1268 56372 Standards and approvals Sentry MCBs are designed to fully comply with the relevant requirements of BS EN 6898: 23. They all feature positive contact status indication

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

TMC 91H is now TMC 60 C Series

TMC 91H is now TMC 60 C Series TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the

More information

DX³ RCBO 6000A Phase + Neutral, neutral on right

DX³ RCBO 6000A Phase + Neutral, neutral on right 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

DSE201 Compact design with enhanced protection

DSE201 Compact design with enhanced protection DSE201 Compact design with enhanced protection The best of safety DSE201 6 ka: the highest level of reliability The 1P+N electronic residual current circuit-breakers with overcurrent protection (RCBOs)

More information

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX 70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications Data Sheet System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

DX³ RCBO 6000A Phase + Neutral, neutral on left

DX³ RCBO 6000A Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

Perfection that Matters

Perfection that Matters Perfection that Matters Switchgear Range Catalogue 2017 Contents Power Series Distribution Boards Classique Distribution Boards Miniature Circuit Breaker Isolator Residual Current Circuit Breaker Residual

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Softstarter Intelligent Controllers

Softstarter Intelligent Controllers Softstarter Intelligent Controllers Series Modes of Operation (Standard) Soft Start 100% Percent Voltage Initial Torque Start Run This method has the most general application. The motor is raised from

More information

T-Switches Range. TL Contactors TS disconnectors TP Contactors. TELARC s multipurpose DC and AC current switches for multiple application.

T-Switches Range. TL Contactors TS disconnectors TP Contactors. TELARC s multipurpose DC and AC current switches for multiple application. TP-PNORM T-Switches Range TL Contactors TS disconnectors TP Contactors TELRC s multipurpose DC and C current switches for multiple application Rolling Stock Energy generation Substation equipment Industrial

More information

Molded case circuit breakers

Molded case circuit breakers Molded case circuit breakers Metasol 30F to 250F Series Type Type and Pole Rated current, In Rated operational voltage, Ue Rated insulation voltage, Ui Rated impulse withstand voltage, Uimp Frame Size(F)

More information

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector Product brochure ABB Fusegear EasyLine Fuse switch disconnector 2 EasyLine Fuse Switch Disconnector ABB Fusegear Content Fuse protection 4 Technical Data 5 General 6 Apparatus overview 7 Electronic Fuse

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

DX³ RCBO 6000 A Phase + Neutral, neutral right side

DX³ RCBO 6000 A Phase + Neutral, neutral right side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7 EP60 Series...7-2 EP100 Series...7-4 EP100 ULH Series...7-6 EP100 UC Series (Branch Circuit Protection)...7-8 Series CA Auxiliary Switch and Bell Alarm...7-10 Series CB Auxiliary Switch and Bell Alarm...7-11

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Btdin-RS RCBO 2p Phase + Neutral, neutral on right Viale Borri 231, 21100 Varese - Italy RCBO 2p CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1 5. General characteristics... 2 6. Compliance

More information

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 / 10 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information