IDEC YC Contactors. New Contactors Now Available
|
|
- Bruno Sherman
- 5 years ago
- Views:
Transcription
1 New ors Now vailable IDEC YC ors
2 TOC & Selection Guide YC ors Table of Contents Selection Guide...2 YC1N(K) Mini ors ccessories...5 Specifi cations...5 Dimensions...6 Electrical Diagrams...6 YC1U Series or (C Coil) ccessories...9 Specifi cations...10 Dimensions...11 Electrical Diagrams...13 YC1N Series ors (C Coil) ccessories...15 Specifi cations...16 Dimensions...17 Electrical Diagram...18 YC1 Series ors (DC Coil) ccessories...20 Specifi cations...21 Dimensions...22 Electrical Diagram...23 Selection Guide Series YC1N(K) Mini series YC1U C Series YC1N C Series YC1 DC Series Coil Voltage C or DC C C DC mp Range (C3) 9 & below Page
3 YC ors YC1N(K) Mini Series YC1N(K) Mini ors Number Key YC1 N Coil Voltage Code N: C Coil K: DC Coil or Size* (5, 6) *See selection table for details. Coil Voltage 24: 24V C, 50/60Hz 120: 120V C, 50/6-Hz 240: C, 50/60Hz 480: 480V C, 50/60Hz D24: 24V DC D110: 110V DC uxiliary rrangement lank: : Selection by Horsepower Rating (C Coil) Rated Power (Hp) per C3 IEC Rated Power (Hp) per UL508 CS C V 1-Phase 3-Phase 1-Phase 3-Phase 220V 380/ 400V 415/ 440V 500V 660/ 690V 110/ 120V 200/ 208V 230/ 440/ 480V 575V uxilary Coil Voltage YC1N-5 YC1N-5 YC1N-6 YC1N-6 24: 24V C 120: 120V C 240: C 480: 480V C Selection by Horsepower Rating (DC Coil) Rated Power (Hp) per C3 IEC Rated Power (Hp) per UL508 CS C Phase 3-Phase 1-Phase 3-Phase 110V 220V 380/ 415/ 400V 440V 500V 660/ 690V 110/ 120V 200/ 208V 230/ 440/ 480V 575V uxilary Coil Voltage YC1K-5 YC1K-5 YC1K-6 YC1K-6 D24: 24V DC D110: 110V DC Switches Unlimited Fax: US: IDEC Canada: IDEC info@switchesunlimited.com 3
4 YC1N(K) Mini Series YC ors Selection by mp Rating (C Coil) Rated Power () per C3 IEC Rated Power () per UL508 CS C Phase 3-Phase 1-Phase 3-Phase 110V 220V 380/ 400V 415/ 440V 500V 660/ 690V 110/ 120V 200/ 208V 230/ 440/ 480V / / V uxilary YC1N-5 YC1N-5 YC1N-6 YC1N-6 Coil Voltage 24: 24V C 120: 120V C 240: C 480: 480V C Selection by mp Rating (DC Coil) Rated Power () per C3 IEC Rated Power () per UL508 CS C Phase 3-Phase 1-Phase 3-Phase 110V 220V 380/ 400V 415/ 440V 500V 660/ 690V 110/ 120V 200/ 208V / 480V / / V uxilary YC1K-5 YC1K-5 YC1K-6 YC1K-6 Coil Voltage D24: 24V DC D110: 110V DC Selection by Kilowatt Rating (C Coil) Rated Power (kw) per C3 IEC Phase 3-Phase 110V 220V 380/400V 415/440V 500V 660/690V uxilary Coil Voltage YC1N-5 YC1N-5 YC1N-6 YC1N-6 24: 24V C 120: 120V C 240: C 480: 480V C Selection by Kilowatt Rating (DC Coil) Rated Power (kw) per C3 IEC Phase 3-Phase 110V 220V 380/400V 415/440V 500V 660/690V uxilary Coil Voltage YC1K-5 YC1K-5 YC1K-6 YC1K-6 D24: 24V DC D110: 110V DC 4
5 YC ors YC1N(K) Mini Series Description Current Range Number 0.3~0.45 YC9Z-RHN5P ~0.67 YC9Z-RHN5P67 Overload Relay 0.67~1 YC9Z-RHN51P0 1~1.5 YC9Z-RHN51P5 1.4~2.1 YC9Z-RHN52P1 1.8~2.7 YC9Z-RHN52P7 2.4~3.6 YC9Z-RHN53P6 3.5~5 YC9Z-RHN55P0 4~6 YC9Z-RHN56P0 5.5~8.5 YC9Z-RHN58P5 8.5~12.5 YC9Z-RHN512P ccessories Description Form (NO) Form (NC) Number Top Mount 2 NC YC9Z-CN202M uxiliary 4 NC YC9Z-CN404M 1 NO 1 NC YC9Z-CN211M 1 NO 3 NC YC9Z-CN413M 2 NO YC9Z-CN220M 2 NO 2 NC YC9Z-CN422M 3 NO 1 NC YC9Z-CN431M 4 NO YC9Z-CN440M Mechanical Interlock YC9Z-CI6 Surge Suppressor Unit 120V C C RC Type VRISTOR RC Type VRISTOR YC9Z-SS1ES YC9Z-SS2ES YC9Z-SS1HS YC9Z-SS2HS General Specifications YC1N-5/6 YC1K-5/6 Confi guration 31a or 31b Making Capacity () 10xIe reaking Capacity () 8xIe Switching Frequency (Operations/Hr) 1,200 Electrical Endurance (Operations) 1,000,000 Mechanical Endurance (Operations) 5,000,000 Operating Temperature -20ºC ~ 55ºC Storage Temperature -40ºC ~ 70ºC Weight (Kg) Note: Ie = rated operational current Main Pole Specifications YC1N-5/6 YC1K-5/6 Insulation Voltage, Ui (V) IEC: 690 UL: 600 Operational Voltage, Ue (V) IEC: 690 UL: 600 Thermal Current, I th () IEC /UL: 20 Short Circuit Current Rating (k) 5 NEM Size Equivalent (approx.) 00 Specifications uxilary s Specifications YC1N-5/6 YC1K-5/6 Insulation Voltage, Ui (V) IEC /UL: 600/600 Operational Voltage, Ue (V) IEC /UL: 600/600 Thermal Current, I th () C: 10 DC: 2.5 Operational Current () IEC UL 508 C DC-13 Q V V V V V V V 0.27 Coil Specifications YC1N-5/6 YC1K-5/6 Pick-up Voltage 50/60Hz 75% 75% Power Consumption, Inrush 27 max. (V) Sealed 5 3 Power Dissipation max. (W) 2 3 Switches Unlimited US: Fax: IDEC Canada: IDEC info@switchesunlimited.com 5
6 YC1N(K) Mini Series YC ors Dimensions or YC1N-5/6, YC1K-5/6 M3.5 screw M4 screws M3.5 screw ccessories Overload Relay YC9Z-RHN5 Top Mounting uxiliary YC9Z-CN TRIP IND. TEST RC. R M 31 I O NC 97 NO NO 98 NC 31 2 T T 4 6 T M4 screw Mechanical Interlock YC9Z-CI Electrical Diagrams YC1N-5/6, YC1K-5/6 ( ux.) L1 L2 L3 NO YC1N-5/6, YC1K-5/6 ( ux.) L1 L2 L3 NC 2 T1 T2 T3 NO T1 T2 T3 NC ll dimensions are in mm. 6
7 YC ors YC1U Series YC1U Series or (C Coil) Number Key YC1U or Size* 9, 11, 16, 18, 27, 32, 38, 50, 65, 80 *see selection table for details Coil Voltage 24: 24V C, 50/60Hz 120: 120V C, 50/60Hz 240: C, 50/60Hz 480: 480V C, 50/60Hz uxilary rrangement lank: (size 9-16) - (size 18-38) 2NO-2NC (size 50-80) : (size 9-16 only) Selection by Horsepower Rating Rated Power (Hp) per C3 IEC Rated Power (Hp) per UL508 CS C Phase 3-Phase 1-Phase 3-Phase 110V 220V 380/ 400V 415/ 440V 500V 660/ 690V 110/ 120V 200/ 208V 230/ 440/ 480V V uxilary YC1U-9 YC1U-9 YC1U-11 YC1U-11 YC1U-16 YC1U-16 Coil Voltage YC1U YC1U YC1U-32 24: 24V C 120: 120V C 240: C 480: 480V C YC1U / NO-2NC YC1U / NO-2NC YC1U NO-2NC YC1U-80 US: IDEC Canada: IDEC 7
8 YC1U Series YC ors Selection by mp Rating Rated Power () per C3 IEC Rated Power () per UL508 CS C Phase 3-Phase 1-Phase 3-Phase 110V 220V 380/ 400V 415/ 440V 500V 660/ 690V 110/ 120V 200/ 208V 230/ 440/ 480V 575V uxilary / YC1U-9 YC1U YC1U-11 YC1U YC1U-16 YC1U YC1U / / YC1U / YC1U / YC1U NO-2NC YC1U NO-2NC YC1U / NO-2NC YC1U-80 Coil Voltage 24: 24V C 120: 120V C 240: C 480: 480V C Selection by Kilowatt Rating Rated Power (kw) per C3 IEC Phase 3-Phase uxilary 110V 220V 380/ 415/ 660/ 500V 400V 440V 690V YC1U-9 YC1U YC1U-11 YC1U YC1U-16 YC1U YC1U YC1U YC1U YC1U / NO-2NC YC1U / NO-2NC YC1U NO-2NC YC1U-80 Coil Voltage 24: 24V C 120: 120V C 240: C 480: 480V C 8
9 YC ors YC1U Series Description or Size Current Range Number Overload Relay Description Mechanical Interlock Side Mount uxiliary 9~22 27~38 50~80 for YC1U-9,11, 16, 18, 22, 27, 32, 38 for YC1U-40, 50, 65, 80 for YC1U-9 thru 40 - (1a1b) 0.3~0.45 YC9Z-RHN10P ~0.67 YC9Z-RHN10P ~1 YC9Z-RHN101P0 1~1.5 YC9Z-RHN101P5 1.4~2.1 YC9Z-RHN102P1 1.8~2.7 YC9Z-RHN102P7 2.4~3.6 YC9Z-RHN103P6 3.5~5 YC9Z-RHN105P0 4~6 YC9Z-RHN106P0 5.5~8.5 YC9Z-RHN108P5 8.5~12.5 YC9Z-RHN1012P 12.5~18 YC9Z-RHN1018P 17~24 YC9Z-RHN1024P 22~30 YC9Z-RHN1030P 17~25 YC9Z-RHN2725P 23~32 YC9Z-RHN2732P 30~40 YC9Z-RHN2740P 37~50 YC9Z-RHN2750P 17~25 YC9Z-RHN5025P 23~32 YC9Z-RHN5032P 30~40 YC9Z-RHN5040P 37~50 YC9Z-RHN5050P 48~65 YC9Z-RHN5065P 63~80 YC9Z-RHN5080P 77~97 YC9Z-RHN5097P Number YC9Z-CI18 YC9Z-CI35 YC9Z-CN111SR ccessories Description Form (NO) Form (NC) Number Top Mount uxiliary 2NC YC9Z-CU202 YC9Z-CU211 2NO YC9Z-CU220 2NO 2NC YC9Z-CU422 3NO YC9Z-CU431 4NO _ YC9Z-CU440 Description Size Coil Voltage Number Replacement Coils 9~22 27~38 50~80 * Standard stock coil voltages. 24V C 110V C 120V C 208V C 220V C C 480V C 24V C 110V C 120V C 208V C 220V C C 480V C 24V C 110V C 120V C 208V C 220V C C 480V C YC9Z-LCU2224* YC9Z-LCU22110 YC9Z-LCU22120* YC9Z-LCU22208 YC9Z-LCU22220 YC9Z-LCU22240* YC9Z-LCU22480* YC9Z-LCU3824* YC9Z-LCU38110 YC9Z-LCU38120* YC9Z-LCU38208 YC9Z-LCU38220 YC9Z-LCU38240* YC9Z-LCU38480* YC9Z-LCU8024* YC9Z-LCU80110 YC9Z-LCU80120* YC9Z-LCU80208 YC9Z-LCU80220 YC9Z-LCU80240* YC9Z-LCU80480* Surge Suppressor Unit 120V C C RC Type VRISTOR RC Type VRISTOR YC9Z-SS1E YC9Z-SS2E YC9Z-SS1H YC9Z-SS2H Switches Unlimited US: Fax: IDEC Canada: IDEC info@switchesunlimited.com 9
10 YC1U Series YC ors Specifications General Specifications YC1U-9 YC1U-11 YC1U-16 YC1U-18 YC1U-27 YC1U-32 YC1U-38 YC1U-50 YC1U-65 YC1U-80 Confi guration 31a, 31b 31a1b 31a1b 32a2b Making Capacity () 10xIe 10xIe 10xIe 10xIe reaking Capacity () 8xIe 8xIe 8xIe 8xIe Switching Frequency (Operations/ Hr) Electrical Endurance (Operations) 1,000,000 1,000,000 1,000, ,000 1,000,000 1,000,000 Mechanical Endurance (Operations) 5,000,000 5,000,000 5,000,000 5,000,000 Operating Temperature -20ºC ~ 55ºC Storage Temperature -40ºC ~ 70ºC Weight (Kg) Note: Ie = rated operational current Main Pole Specifications YC1U-9 YC1U-11 YC1U-16 YC1U-18 YC1U-27 YC1U-32 YC1U-38 YC1U-50 YC1U-65 YC1U-80 Insulation Voltage, Ui (V) IEC: 660 UL: 600 IEC: 660 UL: 600 IEC: 1000 UL: 600 IEC: 660 UL: 600 Operational Voltage, Ue (V) IEC: 660 UL: 600 IEC: 660 UL: 600 IEC: 690 UL: 600 IEC: 660 UL: 600 Thermal Current, I th () IEC: 25 UL: 24 IEC: 32 UL: 35 IEC: 50 UL: 45 IEC: 60 UL: 50 IEC: 60 UL: 55 IEC: 70 UL: 72 IEC: 80/100 UL: 85 Short Circuit Current Rating (k) NEM Size Equivalent (approx.) IEC: 100 UL: 104 uxilary s Specifications YC1U-9 YC1U-11 YC1U-16 YC1U-18 YC1U-27 YC1U-32 YC1U-38 YC1U-50 YC1U-65 YC1U-80 Confi guration 1a or 1b 1a1b 1a1b 1a1b Insulation Voltage, Ui (V) IEC: 600 UL: 600 IEC: 660 UL: 600 IEC: 690 UL: 600 IEC: 660 UL: 600 Operational Voltage, Ue (V) IEC: 600 UL: 600 IEC: 600 UL: 600 IEC: 690 UL: 600 IEC: 660 UL: 600 Thermal Current, I th () C: 10 DC: 2.5 Rating Code Designatior UL 600 Q300 Operational Current () IEC UL 508 C DC-13 Q V V V V V V V 0.27 Coil Specifications YC1U-9 YC1U-11 YC1U-16 YC1U-18 YC1U-27 YC1U-32 YC1U-38 YC1U-50 YC1U-65 YC1U-80 Pick-up Voltage 50-60Hz 70% 75% 75% 75% Power Consumption, Inrush (cos ø = 0.7) 280 max. (V) Sealed (cos ø = 0.3) 32 Power Dissipation max. (W)
11 YC ors YC1U Series ors YC1U-9, YC1U-11, YC1U-16 Dimensions YC1U M YC1U-27, YC1U-32, YC1U-38 YC1U-50, YC1U-65, YC1U-80 M5 M3.5 M6 screw M6 screw NO 13 NO 43 NC 21 NC NC 22 NO 14 NC 32 NO (CU-50,60) 131(CU-80) 150(CU-80) M5 screws M5 screws ll dimensions are in mm. Switches Unlimited Fax: US: IDEC Canada: IDEC 11
12 YC1U Series YC ors ccessories Overload Relays YZ9Z-RHN10 (for YC1U-9, 11, 16, 18) YZ9Z-RHN27 (for YC1U-27, 32, 38, 40) TRIP IND. TEST RC R TRIP IND. TEST RC. R 97 NO 98 NO 95 NC 96 NC M NO NC T1 4 T2 6 T3 2 T T 4 6 T M4 screw M5 screw 97.5 YZ9Z-RHN50 (for YC1U-50, 65, 80) TRIP IND. TEST RC. R M NO 98 NO 95 NC 96 NC 40 2 T1 4 T2 6 T M5 screw M6 screw Mechanical Interlocks YZ9Z-CI18 (for YC1U-9, 11, 16, 27, 32, 38) YZ9Z-CI135 (for YC1U-40, 50, 65, 80) ll dimensions are in mm. 12
13 YC ors YC1U Series Top Mounting uxiliary s YC9Z-CU2 YC9Z-CU Side Mounting uxiliary YC9Z-CN111SR (1a1b for YC1U-9 to YC1U-40) Electrical Diagrams YC1U-9/11/16 ( ux.) YC1U-9/11/16 ( ux.) YC1U-18 to YC1U-38 (- ux.) L1 L2 L3 NO L1 L2 L3 NC NO NC L1 L2 L3 2 T1 T2 T3 NO T1 T2 T3 NC NO 14 NC 22 T1 T2 T ll dimensions are in mm. Switches Unlimited Fax: US: IDEC Canada: IDEC info@switchesunlimited.com 13
14 YC1N C Series YC ors YC1N Series ors (C Coil) Number Key YC1N or Size* 100, 125, 150, 180, 220, 300 *see selection table for details Coil Voltage 24: 24V C, 50/60Hz 120: 120V C, 50/6-Hz 240: C, 50/60Hz 480: 480V C, 50/60Hz Selection by Horsepower Rating Rated Power (Hp) per C3 IEC Rated Power (Hp) per UL508 CS C / 400V 3-Phase 1-Phase 3-Phase 415/ 440V 500V 660/ 690V 110/ 120V 200/ 208V 230/ 440/ 480V 575V uxilary Coil Voltage YC1N YC1N YC1N-150 2NO-2NC YC1N : 24V C 120: 120V C 240: C 480: 480V C YC1N YC1N
15 YC ors YC1N C Series Selection by mp Rating Rated Power () per C3 IEC Rated Power () per UL508 CS C / 400V 3-Phase 1-Phase 3-Phase 415/ 440V 500V 660/ 690V 110/ 120V 200/ 208V 230/ 440/ 480V V uxilary YC1N YC1N YC1N NO-2NC YC1N YC1N YC1N-300 Coil Voltage 24: 24V C 120: 120V C 240: C 480: 480V C Selection by Kilowatt Rating Rated Power (kw) per C3 IEC Phase 380/400V 415/440V 500V 660/690V uxilary YC1N YC1N YC1N NO-2NC YC1N YC1N YC1N-300 Coil Voltage 24: 24V C 120: 120V C 240: C 480: 480V C ccessories Description Size Current Range Number Overload Relay Description Mechanical Interlock Side Mount uxiliary Surge Suppressor Unit 100, , 300 1a1b 120V C C 65~95 YC9Z-RHN10095P 85~125 YC9Z-RHN ~160 YC9Z-RHN ~95 YC9Z-RHN15095P 85~125 YC9Z-RHN ~160 YC9Z-RHN ~160 YC9Z-RHN ~185 YC9Z-RHN ~160 YC9Z-RHN ~185 YC9Z-RHN RC Type VRISTOR RC Type VRISTOR Number YC9Z-CI100 YC9Z-CN111C YC9Z-SS1E YC9Z-SS2E YC9Z-SS2H YC9Z-SS1H Description or Size Coil Voltage Number 24VC YC9Z-LCN12524* 110VC YC9Z-LCN VC YC9Z-LCN125120* 100, 125 Replacement Coils 150, , 300 * Standard stock coil voltages. 208VC YC9Z-LCN VC YC9Z-LCN C YC9Z-LCN125240* 480VC YC9Z-LCN125480* 24VC YC9Z-LCN18024* 110VC YC9Z-LCN VC YC9Z-LCN180120* 208VC YC9Z-LCN VC YC9Z-LCN C YC9Z-LCN180240* 480VC YC9Z-LCN180480* 24VC YC9Z-LCN30024* 110VC YC9Z-LCN VC YC9Z-LCN300120* 208VC YC9Z-LCN VC YC9Z-LCN C YC9Z-LCN300240* 480VC YC9Z-LCN300480* Switches Unlimited US: Fax: IDEC Canada: IDEC info@switchesunlimited.com 15
16 YC1N C Series YC ors Specifications General Specifications YC1N-100 YC1N-125 YC1N-150 YC1N-180 YC1N-220 YC1N-300 Confi guration 32a2b Making Capacity () 10xIe reaking Capacity () 8xIe Switching Frequency (Operations/ Hr) 1,200 Electrical Endurance (Operations) 1,000,000 Mechanical Endurance (Operations) 5,000,000 Operating Temperature -20ºC ~ 55ºC Storage Temperature -40ºC ~ 70ºC Weight (Kg) Note: Ie = rated operational current Main Pole Specifications YC1N-100 YC1N-125 YC1N-150 YC1N-180 YC1N-220 YC1N-300 Insulation Voltage, Ui (V) IEC: 1000 UL: 600 IEC: 1000 UL:600 IEC: 1000 UL:600 Operational Voltage, Ue (V) IEC: 690 UL:600 IEC: 690 UL:600 IEC: 690 UL:600 Thermal Current, I th () IEC: 35 UL: 130 IEC/UL: 150 IEC/UL: 200 IEC/UL: 240 IEC/UL: 260 IEC/UL: 350 Short Circuit Current Rating (k) NEM Size Equivalent (approx.) uxilary s Specifications YC1N-100 YC1N-125 YC1N-150 YC1N-180 YC1N-220 YC1N-300 Insulation Voltage, Ui (V) IEC: 660 UL:600 Operational Voltage, Ue (V) IEC: 660 UL: 600 Thermal Current, I th () C: 10 DC: 2.5 Rating Code Designatior UL 600 Q300 Operational Current () IEC UL 508 C DC-13 Q V V V V V V V 0.27 Coil Specifications YC1N-100/YC1N-125 YC1N-150/YC1N-180 YC1N-YC1N-300 Pick-up Voltage 50/60Hz 83% 75% 75% Drop-out Voltage 45% 45% 45% Power Consumption, Inrush max. (V) Sealed Power Dissipation max. (W)
17 YC ors YC1N C Series Dimensions ors YC1N-100, YC1N-125 YC1N-150, YC1N-180 M8 screw M8 screw 2-M5 screws M5 screws M5 screws M5 screws YC1N-220, YC1N-300 M10 M3.5 M M M ll dimensions are in mm. Switches Unlimited US: Fax: IDEC Canada: IDEC info@switchesunlimited.com 17
18 YC1N C Series YC ors ccessories Overload Relay YC9Z-RHN100 YC9Z-RHN Ø Ø M8 screw 33 4mm 33 M8 screw 33 4mm YC9Z-RHN180 YC9Z-RHN Ø Ø mm 33 M10 screw 33 s 4mm 33 M10 screw 33 Mechanical Interlock YC9Z-CI100 Side Mounting uxilary YZ9Z-CN111C (1a1b) M YC1N-100 to YC1N NO NC L1 L2 L NO NC Electrical Diagram ll dimensions are in mm. 2 NO 14 NC 22 T1 T2 T NO 44 NC
19 YC ors YC1 DC Series YC1 Series ors (DC Coil) Number Key YC1 9 D24 or Size* 9, 12, 18, 22, 32, 40, 50, 65 *see selection table for details Coil Voltage D24: 24V DC* D48: 48V DC D110: 110V DC D125: 125V DC uxilary rrangement lank: (size 9-12) & (size 18-65) : (size 9-12) Selection by Horsepower Rating Rated Power (Hp) per C3 IEC Rated Power (Hp) per UL508 CS C Phase 3-Phase 1-Phase 3-Phase 110V 220V 380/ 400V 415/ 440V 500V 660/ 690V 110/ 120V 200/ 208V / 480V 575V uxiliary Coil Voltages / YC1-9 YC / YC1-12 YC YC YC YC1-32 D24: 24V DC* D48: 48V DC D110: 110V DC D125: 125V DC YC YC YC1-65 * Standard coil voltage. Switches Unlimited Fax: US: IDEC Canada: IDEC info@switchesunlimited.com 19
20 YC1 DC Series YC ors Selection by mp Rating Rated Power () per C3 IEC Rated Power () per UL508 CS C22.2 () 1-Phase 3-Phase 1-Phase 3-Phase 110V 220V 380/ 400V 415/ 440V 500V 660/ 690V 110/ 120V 200/ 208V 230/ 440/ 480V V uxiliary YC1-9 YC1-9 Coil Voltages YC1-12 YC YC YC YC1-32 D24: 24V DC* D48: 48V DC D110: 110V DC D125: 125V DC YC YC YC1-65 * Standard coil voltage. Selection by Killowatt Rating Rated Power (kw) per C3 IEC Phase 3-Phase 110V 220V 380/400V 415/440V 500V 660V 690V uxiliary Coil Voltages YC1-9 YC YC1-12 YC YC YC YC1-32 D24: 24V DC* D48: 48V DC D110: 110V DC D125: 125V DC YC YC YC1-65 * Standard coil voltage. ccessories Description Mechanical Interlock Number YC9Z-CI65 Description Form (NO) Form (NC) Number - 2NC YC9Z-C202 YC9Z-C211 Top Mount uxiliary 2NO - YC9Z-C220 3NO YC9Z-C431 4NO - YC9Z-C440 Side Mount lock YC9Z-C211S Description or Size Coil Voltage Number Replacement Coils 9~12 18~22 32~40 50~65 * Standard stock coil voltages. 24VDC 48VDC 110VDC 125VDC 24VDC 48VDC 110VDC 125VDC 24VDC 48VDC 110VDC 125VDC 24VDC 48VDC 110VDC 125VDC YC9Z-LC12D24* YC9Z-LC12D48 YC9Z-LC12D110 YC9Z-LC12D125 YC9Z-LC22D24* YC9Z-LC22D48 YC9Z-LC22D110 YC9Z-LC22D125 YC9Z-LC40D24* YC9Z-LC40D48 YC9Z-LC40D110 YC9Z-LC40D125 YC9Z-LC65D24* YC9Z-LC65D48 YC9Z-LC65D110 YC9Z-LC65D
21 YC ors YC1 DC Series Specifications General Specifications YC1-9 YC1-12 YC1-18 YC1-22 YC1-32 YC1-40 YC1-50 YC1-65 Confi guration 31a, 31b 31a1b 31a1b 31a1b Making Capacity () 10xIe 10xIe 10xIe 10xIe reaking Capacity () 8xIe 8xIe 8xIe 8xIe Switching Frequency (Operations/ Hr) Electrical Endurance (Operations) 1,000,000,000 10,000,000 10,000,000 1,000,000,000 Mechanical Endurance (Operations) 100,000,000 1,000,000 1,000, ,000,000 Operating Temperature -20ºC ~ 65ºC Storage Temperature -40ºC ~ 70ºC Weight (Kg) Note: Ie = rated operational current Pole Specifications YC1-9 YC1-12 YC1-18 YC1-22 YC1-32 YC1-40 YC1-50 YC1-65 Insulation Voltage, Ui (V) IEC: 690 UL: 600 IEC: 1000 UL: 600 IEC: 1000 UL: 600 IEC: 1000 UL: 600 Operational Voltage, Ue (V) IEC: 690 UL: 600 IEC: 690 UL: 600 IEC: 690 UL: 600 IEC: 690 UL: 600 Thermal Current, I th () IEC: 20 UL: 20 IEC: 35 UL: 30 IEC: 60 UL: 50 IEC: 60 UL: 55 IEC: 80 UL: 70 NEM Size Equivalent (approx.) IEC: 80 UL: 80 uxilary Circuit Specifications YC1-9 YC1-12 YC1-18 YC1-22 YC1-32 YC1-40 YC1-50 YC1-65 Confi guration 1a or 1b 1a1b Insulation Voltage, Ui (V) IEC: 660 UL: 600 Operational Voltage, Ue (V) IEC: 660 UL: 600 Thermal Current, I th () 10 Rating Code Designatior UL 600 Q300 Rated Operational Current () IEC UL 508 C DC-13 Q V V V V V V V 0.27 Coil Specifications YC1-9 YC1-12 YC1-18 YC1-22 YC1-32 YC1-40 YC1-50 YC1-65 Pick-up Voltage 50/60Hz 75% Power Consumption, max. Inrush (V) Sealed 3 Power Dissipation max. (W) 3 Switches Unlimited US: Fax: IDEC Canada: IDEC info@switchesunlimited.com 21
22 YC1 DC Series YC ors Dimensions or YC1-9, YC1-12 YC1-18, YC M YC1-32, YC1-40 YC1-50, YC1-65 M M M ll dimensions are in mm. 22
23 YC ors YC1 DC Series ccessories Mechanical Interlock YC9Z-CI Side Mounting uxilary YC9Z-C211S (1a1b) Top Mounting uxilary YC9Z-C2 (2b, 1a1b, 2a) YC9Z-C4 (3a1b, 4a) Electrical Diagrams YC1-9/12 () YC1-9/12 () YC1-18 to YC L1 L2 L3 NO L1 L2 L3 NC NO NC L1 L2 L3 2 T1 T2 T3 NO T1 T2 T3 NC NO 14 NC 22 T1 T2 T Switches Unlimited Fax: US: IDEC Canada: IDEC info@switchesunlimited.com 23
A200 NEMA Contactors and Starters A200
Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws
More informationContactors & Overload relays
Contactors & Overload relays Metasol MC 3P 18 to 100 MC type Magnetic Contactors Frame size screws clamp terminals Number of poles Rated operational voltage, Ue Rated insulation voltage, Ui Rated frequency
More informationTechnical Information
Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,
More informationGeneral + Definite Purpose Contactors
General + Definite Purpose Contactors General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Contactors Series C8 Miniature Contactors and Starters... 3
More informationContactor Types CI 61-98
MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories
More informationMAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-
MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4
More informationManual Motor Protectors
88 Manual Motor Protectors 51 30 UP TO IMM16 Frame IMM32 Frame IMM65 Frame E468295 E468295 High interrupt capacity up to 100k (with optional current limiter) Din rail mounting Lockable handle (OFF position)
More informationSeries CA6 Contactors
Series C6 Contactors classic contactor for demanding applications from 75 to 600HP (@460V) - 100 to 700HP (@ 575V) This series is being replaced by the C9 Series of contactors Sprecher + Schuh s C6 contactor
More informationEW series Industrial contactors
2012_EW_Contactors_bro_EN.qxd:Mise en page 1 31/08/12 10:24 Page 2 EW series Industrial contactors Hager offers a complete range of contactors for commercial market such as buildings, infrastructures,
More informationMini Contactors CI 4-
Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they
More informationASL09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil
More informationTechnical Information
C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /
More informationApproved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories
Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated
More informationKtec Contactors and thermal overloads
Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America
More informationStandard voltages. Alternating current (V) 50/60Hz Alternating current (V)
Series CK Three and four pole contactors 150 to 825 (C3) 200 to 1250 (C1) Control circuit: lternating current up to 690V Direct current up to 500V Degree of protection IP00 (IPxx with accessories) CK07...CK13:
More informationSolenoid Locking Safety Switches
HSC HSC Full Size Solenoid Locking Switches Key features: Rugged aluminum die-cast housing 00N locking retention force Flexible Installation: The actuator can be accessed from two directions Select from
More informationCTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.
More informationSeries CA5 Contactors
Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower
More informationTechnical Information
Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More information22AF 40AF AF 150AF 225AF 400AF 800AF
Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug
More informationESW/PESW. Non-Combination Starters
ESW/PESW Enclosed Non-Combination General WEG offers non-reversing and non-combination magnetic starters up to 75HP at 460Vac (105). Featuring components that meet IEC design standards and UL horsepower
More informationSolenoid Locking Safety Switches
Locking Safety Switches HSE HSE Full Size Locking Switches Key features: Plastic Housing: Lightweight 00N locking retention force Available with a red or green indicator Choose from circuit configurations
More informationThe contactor for large horsepower applications
Series The complete contactor for heavy industrial applications from 500HP to 900HP R Series contactors provide large horsepower performance with a design that is up to 40% smaller than traditional contactors
More informationand Refrigeration Institute). CNX Special Purpose Contactors
Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More information[V] Common Control Transformer Control (See page 1-78 Note)
Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state
More informationGeneral + Definite Purpose Contactors
General + Definite Purpose General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Series C8 Miniature and Starters... 3 ccessories... 2 Contactor Cross
More informationMetasol MC 4pole. Contactor. Overview 108 Table of specifications 110 Dimension 114. Contents
Metasol MC Contactor Overview 8 Table of specifications 1 Dimension 114 Contents Series completion More Safe, More Valuable Contactors & Overload Relays dvanced technology & Expert solution Offering economical
More informationPage 2-4 Page 2-8. Page Page 2-12
Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V
More informationMini contactors. Mini contactors providing various connections and Accessories. Screw clamps. Ratings. For fast-on connections
Mini contactors providing various connections and Accessories Screw clamps Fast-on Ratings AC3 ratings (IEC609-) Frame size 220 ~ 280 ~ 0 ~ 20V 0V 5V 690V 6A 1.5kW 2.2kW 3kW 3kW A 6A 5A A 9A 2.2kW kw 3.kW
More informationContactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors.
Contactors E Line contactors. E Line contactors. xstart series contactors.3 xstart C series contactors.4 D Line contactors xstart series contactors xstart C series contactors D Line contactors X UTOMTION
More informationC -5 to +55 (0.8 to 1.1Uc) Permissible o
T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationContactors. 1.1 E Line contactors Control relays XTRG... 1 Contactors XTCG... 4
Contactors E Line contactors xstart series contactors. E Line contactors Control relays XTRG....................................................... Contactors XTCG.........................................................
More informationRelays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada
Key features: SPDT through PDT, 0 contacts Midget power type relays vailable in pin and blade terminal styles. Options include an indicator, check button for test operations and side flange. Series Power
More informationA Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.
C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,
More informationRSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX
IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description
More information1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.
SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary
More informationSeries CK. Contactors. Intro. Mounting positions
onformity to standards /N 60947-1 N 63-110 S 5424 & 775 /N 60947-4-1 S 1025 NM S 1 NL 419 S 22.2/14 V 0660/102 UL 508 UN 20109 N 50005 pprovals/marking culus RN NOM Lloyd s Register ureau Veritas mbient
More informationMotor Starting Solutions Open Type Version, in Kit Form
Motor Starting Solutions Open Version, in Kit Form Starters Protected by Manual Motor Starters Direct-On-Line Starters I> Reversing Starters I> MS... Manual motor starter MS... Manual motor starter BEA...
More informationDoor Interlock Switches
HSE Series HSE Series Full Size Locking Switches Overview X Series E-Stops HSE features: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal screws
More informationMS25, MST25, MS20, MST20
Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers
More informationCrane Control Class 9055
Catalog 17 CONTENTS Description.....................................................Page pplication Data................................................... General Information and Pricing.......................................
More informationTechnical Information
Electrical Data C7-9 Rated Insulation Voltage U i IEC, S,BS,SEV, VDE 0660 [V] 690V UL; CS [V] 600V Rated Impulse Voltage U imp [kv] 8kV Rated Voltage U e -Main Contacts C7 3-Pole Contactors C7-2 C7-6 C7-23
More informationCatalog Issued 3-03 (PDF Rev )
W6/W9 series Magnetic Hydraulic P& Circuit reakers Features Designed for the international market. UL Recognized (UL77 and UL5), CS ccepted and VDE approved. Ratings to 5 amps. Heavy duty #-32 stud connections.
More informationCI-TI TM Contactors and Motor Starters Contactors CI 6-50
Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9
More informationAbout us. Switchgear Factory, Mumbai
About us Larsen & Toubro is a technologydriven USD 8.5 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction,
More informationSIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function
The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole
More informationHS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.
HSB Series HSB Series Full Size Interlock Switch HSB features: Body Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded
More informationElectrical sector solutions E Line family. Industry leading design in a compact package
Electrical sector solutions E Line family Industry leading design in a compact package Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability
More informationDoor Interlock Switches
HS5B Series HS5B Series Miniature Interlock Switch HS5B features: mm x mm x 9mm Compact Housing Available with Contact Confi gurations (NO + NC or NC) Flexible Installation: By turning the head of the
More informationEfficor* Intro. Conformity to standards. Ambient conditions. Climatic resistance (IEC 68-2) Approvals/Marking. Mounting positions
fficor* onformity to standards /N 60947-1 04 /N 60947-4-1 UL508 /N 60947-5-1 UL486 /N 60947-5-4 S22- N500 N 16 101/102 N50012 N50005 pprovals/marking mbient conditions Storage temperature -55º to +80º
More informationMPW Series. MPW Catalog Number Sequence. Standard Features MPW U004
Series The WEG Series Manual provide a very compact solution for operation and protection in motor control applications. The NEC requires four functions to be considered a combination motor starter:, ranch,
More informationOperation and Protection of Motors up to 600Hp at 460Vac (800A)
Operation and of Motors up to 600Hp at 460Vac (800) WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications. Featuring components
More informationStandard voltages. Alternating current (V) /60Hz Alternating current (V)
Series K Three and four pole contactors 150 to 825 (3) 200 to 1250 (1) ontactors ontrol circuit: lternating current up to 690V irect current up to 500V egree of protection P00 (Pxx with accessories) K07K13:
More informationCI-TI Contactors and motor starters Types CI 61 - CI 98
Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include
More informationElectrical sector solutions E Line family. Industry leading design in a compact package
Electrical sector solutions E Line family Industry leading design in a compact package The power of fusion. 87 88 89 899 90 908 9 9 9 9 97 97 977 98 98 989 999 There s a certain energy at Eaton. It s the
More informationDefinite Purpose Contactors
1 & 2 Pole - Series CDP2 One and Two Pole with C Coil (Open type only) ➍ mps Poles Locked Rotor mps mps ➋ Maximum H.P. 240V ➋ 480V 600V 120V 240V ➋ 30 ➊ 1 ➏ 150 75 50 40 1 2 CDP2-1P30- ➎ 69.54 50 30 ➊
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating
ECP180 Series Low 1 Profile High Power Density 2.0 by 4.0 Footprint 120W Convection-cooled Rating 180W Force Cooled Rating Medical & ITE pprovals Class I and Class II pplications High Efficiency, up to
More informationAmbient temperature compensation (-40F to +1400F) Phase loss sensitivity protection, Current unbalance sensitivity.
www.we.net Thermal Overload Relays - RW Series Rated for the new industry RW overload relays are an important part of WEG rane of products. s usual in WEG products, an extended operational service life
More informationIEC Contactors. IEC Contactors. YS Series. YS Series Contactors YS1N- F11 ****
YS Series Contactors Key features of the YS Series include: Compact size AC and C coil, reversing and non-reversing Weld-resistant silver alloy contacts No cadium used in contacts Highly reliable auxiliary
More informationTECHNICAL DESCRIPTION
DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650515200 Ed.1 of 21/02/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More informationQuick selection table
Quick selection table Contactors... 100 to 800A Frame size 100A 15A 150A -pole Contactors s AC/DC common coil See page 46 for more details CGC-100 CGC-15 CGC-150 See page 46 for more details Ratings /
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series
More informationRelays & Sockets. RQ Series PCB Relays
RQ RQ Series PCB Relays IDEC RQ relays are low-profile, PCB relays in a compact package. Size equals value. RQ relays are small, yet maintain high contact ratings and long operational life. For larger
More informationSwitches Unlimited Phone: * Fax:
For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings
More informationStandard Interlock Safety Switches
Subminiature Interlock Switches Key features: Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening
More informationStandard voltages. Alternating current (V) /60Hz Alternating current (V)
Three and four pole contactors 50 to 825 (3) 200 to 250 () ontactors ontrol circuit: lternating current up to 690V irect current up to 500V egree of protection P00 (Pxx with accessories) K07K3: auxiliary
More informationP-SERIES VFD WITH BYPASS
P-SERIES VFD WITH BYPSS 1 40 HP (200~230 VC) 1 100 HP (380~480 VC), 3Ø Enclosed Bypass - UL Type 3R Standard Controls for Bypass & Local/Remote Operation Special Instructions: FETURES ND OPTIONS Compact
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationmax pole for t=15 ms
Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationHS7A-DMC Non-contact Interlock Switches
Non-contact Interlock es Compact size and easy positioning. Combination with proprietary relay modules achieves safety category 4 (EN954-1). Compact size (7 16 51mm) Positioning for installation is easy.
More informationContactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660
Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,
More informationHS1E Series Full Size Interlock Switch with Locking Solenoid
HS1E Series HS1E Series Full Size Interlock Switch with Locking Solenoid HS1E Key features include: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationPower Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers
Standard Series Key features: Wide power range: 7.W-4W Universal input : 7.W-W: 8-264V /1-37V DC W: 8-2V /17-264V 24-37V DC (selectable) W, W, 24W: 8-264V /11-3V DC 4W: 3 phase: 32- V 3 phase: 3- V Overcurrent/overvoltage
More informationTeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30
Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,
More informationNEMA Contactors & Starters A200
March 007 NM ontactors & Starters 00 ontactors Non-reversing and Reversing -7 ontents escription Page ontactors Non-reversing and Reversing............ -7 Product escription Sizes 00 4............ -7 Product
More informationSIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC
and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar
More informationContactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30
Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable
More informationSIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC
SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar
More informationSafety switches for hinged doors
4 Safety switches for hinged doors Selection diagram FR FM FX FZ FK 5 18 7 9 snap action overlapped CONTACT BLOCKS 20 21 22 33 34 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland
More informationSubmittal Data Information
Effective: NOVEMBER 3, 2014 JOB CONTRCTOR ITEM NO. Submittal Data Information TS - Taco dvanced Starter ENGINEER REP. 301-2690 Supersedes: NEW TS - Taco dvanced Starter 1Ø, 120-230V, 1/10-30HP 3Ø, 200-600V,
More informationContactors & Starters. Definite Purpose. Definite Purpose Contactors & Starters C-1. Contents
Definite Purpose ontactors & Starters - July 007 Definite Purpose ontactors & Starters ontents Description Page Product Family Overview pplication Description........................................ -
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationLow Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays
CWB and RW27-2D IEC Contactors and Thermal Overload Contactors Overload A-2-800-ASK4WEG www.weg.net/us Contactors CWB CWB Features A-4 Catalog Number Format A-7 Accessories Overview A-8 Part Number List
More informationTechnical data OT16E3 OT160E3 UL & CSA
Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58
More informationContactors (9 to 85A)
Contactors (9 to 85A) Frame size 9A 12A 18A 22A -pole Contactors For further technical information see pages 8-9. includes AU-1 auxililary switch, (1 N.O. / 1 N.C.) Types AC coil DC coil GMC-9 GMD-9 GMC-12
More informationLighting Contactors. 6.1 Open Control. Product Overview...
Lighting Contactors C30CN Mechanically and Electrically Held.1 Product Overview........................................ C30CN Mechanically and Electrically Held Product Description....................................
More informationStandard voltages. Alternating current (V) /60Hz Alternating current (V)
Three and four pole contactors 50 to 825 (3) 200 to 250 () ontactors ontrol circuit: lternating current up to 690V irect current up to 500V egree of protection P00 (Pxx with accessories) K07...K3: auxiliary
More informationAF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationNSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals
NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low
More informationABB s new control and protection devices
ABB s new control and protection devices One product family ABB presents a new generation of first-class specialized components: manual motor starters, contactors, overload relays and softstarters for
More informationDC MILL DUTY CONTACTORS
DC MILL DUTY CONTCTORS DC Mill Duty Contactors 900 Range (Rating 15, 25, 50, 150, 300 & 600) BCH DC type 900 Mill Duty Contactors have been designed keeping in view the arduous environment and duty conditions
More information28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description
.1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is
More informationHS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality
Full Size Interlock Switch with Locking Solenoid HSC Key features include: Rugged Aluminum Die-cast Housing With the actuator mounted on a movable door, and the switch on a machine, the door can be mechanically
More information