1 Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V and 600V C, DC and DC low-consumption coil. FOUR-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 0 to 1600 IEC Power ratings in C1 400V duty: 14 to 950kW UL/CS general use: 16 to 1000 C, DC and DC low-consumption coil. Page -1 FOUR-POLE CONTCTORS WITH NO+NC MIN POWER POLES IEC Ith ratings in C1 duty at 40 C: 0 to 60 UL/CS general use: 0 to 55 C, DC and DC low-consumption coil. Page -13 FOUR-POLE CONTCTORS WITH 4NC MIN POWER POLES ND FOR PHOTOVOLTIC PPLICTIONS IEC Ith ratings in C1 duty at 40 C: 5 to 40 and UL/CS general use: 0 to 55 for 4NC types IEC 15 operational current in DC1 duty at 55 C with 4NO main poles in series for BFD80 types C, DC and DC low-consumption coil. Page -14 CONTCTORS FOR POWER FCTOR CORRECTION With limiting resistors included IEC Power ratings at 400V: 7.5 to 60kvar UL/CS ratings: 9 to 65kvar at 480V; 10 to 70kvar at 600V C control coil. Pag. -15 CONTROL RELYS C, DC and DC low-consumption coil Screw or Faston termination 4, 8 or 11 auxiliary contact composition.

2 CONTCTORS Three-pole versions up to 630 in IEC C3 duty Four-pole versions up to 1600 in IEC C1 duty Versions for power factor correction up to 60kvar at 400VC Four-pole versions with NO+NC or 4NC main poles Low-consumption versions with DC control circuit for control relays and 9-38 contactors in IEC C3 duty Versions with C or DC control Extensive choice of add-on blocks and accessories Certified by primary international authorities. SEC. - PGE Contactors Three-pole Four-pole Four-pole with NO and NC poles or 4NC poles Four-pole with 4NO poles for photovoltaic applications For power factor correction Control relays dd-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors Spare parts C coils for BF series contactors DC coils for BF series contactors C/DC coils for B series contactors Main contacts for BF series contactors Main contacts and arc chutes for B series contactors Wiring diagrams Positive (force) guided contacts MOTOR CONTROL ND PROTECTION

3 BG series mini-contactors Unique features Highly conductive auxiliary contacts with four contact points C and DC versions of same size Quick connect - snap on accessory mounting Distinct contact status indication Up to four auxiliary contacts can be mounted Mechanical interlock only 5mm deep Positive (force) guided contacts (mechanically-linked per IEC) Three-pole mini-contactors, 6 to 1 IEC C3 duty / 3 to 7.5HP 480V - 3 to 10HP 600V UL/CS Four-pole mini-contactors, 0 IEC C1 duty Versions with NO+NC main power poles Highly conductive auxiliary contacts C or DC auxiliary supply Low-consumption DC versions Screw, faston and rear PCB solder pin termination. 3 poles 4 poles IEC Coil in IEC Coil in Ie (C3) C DC Ith (C1) C DC BG06 6 BG BGF BGP BG1 1 BF series contactors Unique features Highly conductive auxiliary contacts with four contact points Quick connect - snap on accessory mounting Distinct contact status indication Up to four auxiliary contacts can be mounted Mechanical interlock only 5mm deep Positive (force) guided contacts (mechanically-linked per IEC) Three-pole contactors, 9 to 110 IEC C3 duty / 5 to 75HP 480V to 100HP 600V UL/CS Four-pole contactors, 5 to 15 in C1 duty Power factor correction contactors, 7.5 to 60kvar at 400V IEC / 9 to 65kvar at 480V UL/CS Types with NO+NC or 4NC main power poles Types for photovoltaic applications Highly conductive auxiliary contacts C or DC auxiliary supply Low-consumption versions for control relays and 9-38 contactors in IEC C3 duty. 3 poles 4 poles IEC Coil in IEC Coil in Ie C DC DC❶ Ith C DC DC❶ (C3) (C1) BF BF1 1 8 BF BF5 5 BF BF3 3 BF BF BF BF BF95 95 BF ❶ Low-consumption version. B series contactors Unique features 3 frame sizes offering 11 different contactors Coil operates indifferently on C or DC supply voltage Coil with low in-rush and holding Coil removable without disconnecting power wiring Red indicator when contactor is energised Unique right-angle magnet design - limits contact bounce Safety feature prevents contactor to be energised without arc chute in place and locked Convertible auxiliary contact block (NO + 1NC or 1NO + NC), maximum of 4 blocks per contactor for a total of 1 contacts Contactor terminals with bolt, washer and nut Simple horizontal or vertical interlock Positive (force) guided contacts (mechanically-linked per IEC) Three-pole contactors, 110 to 630 IEC C3 duty Four-pole contactors, 160 to 1600 IEC C1 duty 100 to 500HP 600V UL/CS Screw termination. 3 poles 4 poles IEC Coil both IEC Coil both Ie (C3) C DC Ith (C1) C DC B B B B B B B B B ❶ 1000 B150 ❶ 150 B1600 ❶ 1600 ❶ For C1 / general use duty only. General information - IEC contactors Lovato Electric comprehensive line of contactors can be divided in to three basic configurations as illustrated above. Each of these have unique features but all are designed for long life and have finger-safe protection. Lovato Electric facilities, where these contactors are manufactured, work under ISO 9001 quality conditions, per IQNet certification since 199 and constantly maintained by passing yearly quality assurance audits. The design and manufacture of the contactors and accessories have taken into consideration the most demanding requirements of international standards. Non-reversing and reversing IEC starters Contactors can be combined with either manual motor starters of the SM series, providing thermal and magnetic protection up to 100, or single or three-pole thermal bimetallic overload relays, with or without single-phase protection up to 40, to obtain non-reversing or reversing starters. Equipment can be assembled together or independently mounted through the use of specifically designed accessories. Non-reversing starter Reversing starter -

4 Contactors BF00, BF09... BF38 THE IDEL SOLUTION! 1 45mm WIDE CONTCTORS Ratings up to kW IEC C3 / 30HP UL - merely 45mm wide: exceptional benefit for electric panel dimensions. 4-TERMINL COIL Connecting cables can be coupled to the coil both on the line and load ends of the contactor. 1 BUILT-IN SURGE SUPPRESSOR The BF00 to BF38 contactors with standard voltage DC coils include a built-in surge suppressor. WIDE OPERTING RNGE BF...D contactors are equipped with a wide operating range coil and are particularly useful in applications subject to considerable voltage variations, such as in electric traction railway equipment. LOW-CONSUMPTION COILS The BF...L contactors feature a.4w low consumption. This characteristic widely allows their direct control by PLC outputs. SIDE DD-ON FOURTH POLE For the 45 and 56 C1 ratings, a side-mount fourth power pole can be snapped on the three-pole contactor. This solution permits to optimise inventory. STRTER SSEMBLY TERMINL DPTBILITY Terminals are suitable for every type of cable: flexible, rigid, according to WG standards and interlocked with any type of cable terminal. Power pole, auxiliary and coil screws can be tightened using one single type of screwdriver. FRONT PROTECTION COVER FOR BREKER - CONTCTOR CONNECTIONS MECHNICL INTERLOCK Smaller-size contactors, 9 to 5 in C3, can be mechanically and electrically interlocked with larger-size contactors, 6 to 38 C3. The BFX50 01 mechanical interlock comprises two built-in NC auxiliary contacts to make the electrical interlock as well. The assembly and wiring of electromechanical starters is extremely fast and reliable. Versatile electrical and mechanical connecting systems provide easy and foolproof assembly of compact starters. EFFORTLESS THERML OVERLOD RELY LINK SNP-ON INSTLLTION The front cover, fixed between breaker and contactor, provide protection to the connections. 35mm DIN RIL MOUNTING ND FIXING Mounting and removal of the addon auxiliary contacts and accessories, along with BF09 to BF38 C contactor coil replacement are quick and easy operations and are done with no tools. IP0 CONNECTION SECURITY Contactor mounting on and removal from a 35mm DIN rail are tool-less operations and are done by simply applying pressure on the contactor. During the connection of the thermal overload relay to the contactor, its auxiliary contact is simultaneously linked to the contactor coil terminal rigid connector. The complete overload relay fixing is obtained with one single operation and without other connections. RUBBER PD INSERT FOR NO DIN RIL SLIDING The ease of terminal access and space is combined with IP0 finger safety, to prevent touching of live parts. rubber insert prevents the contactors from sliding on the 35mm DIN rail even when out of tolerance or mounted vertically. -3

5 Three-pole contactors with C control circuit BG06 -BG1 BF09 -BF5 BF6 -BF38 BF50-BF110 B115-B180 B50-B400 Three-phase motor control in C3 duty UL/CS details Order code IEC operating current Maximum IEC power at 55 C (C3) Maximum UL/CS horsepower ratings Ith (C1) Ie (C3) Single phase Three phase C coil 40 C 55 C 70 C 440V at 55 C 30V 400V 415V 440V 500V 690V 1000V 10V 40V 00V 40V 480V 600V [] [] [] [] [] [kw] [kw] [kw] [kw] [kw] [kw] [kw] [HP] [HP] [HP] [HP] [HP] [HP] 11 BG06 01 ❶ / / BG06 10 ❶ ( 60 C) 11 BG09 01 ❶ / 1 1 / BG09 10 ❶ ( 60 C) 11 BGF09 01 ❶ / 1 1 / BGF09 10 ❶ ( 60 C) 11 BGP09 01 ❶ ❼ 4.3❼ 4.5❼ 5❼ 1 / 1 1 / 3 5❼ 11 BGP09 10 ❶ ( 60 C) 11 BG1 01 ❶ / 1 1 / / BG1 10 ❶ 1 ( 60 C) BF09 01 ❶ / / BF09 10 ❶ 1 BF1 01 ❶ / 10 BF1 10 ❶ 1 BF18 01 ❶ BF18 10 ❶ 1 BF5 01 ❶ / 7 1 / BF5 10 ❶ BF6 00 ❶ / 7 1 / 15 0 BF3 00 ❶ / BF38 00 ❶ 56 (60❿) 45 (48❿) 40 (4❿) / BF50 00❶ BF65 00❶ BF80 00❶ BF95 00❶ BF110 00❶ B115 00❷❸ B145 00❷❸ B180 00❷❸ B50 00❷❸ B310 00❷❺ B400 00❷❸ B500 00❷❸ B630 00❷❸ B ❷❺ For C1/Resistive duty only, see page B150 4❺❻ For C1/Resistive duty only, see page -8. No UL 11 B1600 4❺❻ For C1/Resistive duty only, see page -8. No UL ❶ Complete order code with coil voltage digit or with voltage digit followed by 60 (if 60Hz). Standard voltages are as follows: -- C 50/60Hz 04 / 048 / 110 / 30 / 400V -- C 60Hz / / / 0 60 / / / (V). Example: 11 BG for mini-contactor BG06, three poles, with one NO contact and 30VC 50/60Hz coil. 11 BG for mini-contactor BG06 with one NO contact and 460VC 60Hz coil. ❷ The coil of the contactor can be powered indifferently in C or DC. Complete the order code only with the digit of the coil voltage. Standard voltages are: -- C/DC 4 / 48 / 60 / (indicate 110) / 0-40 (indicate 0) / (indicate 380) / V (indicate 440). Example: 11 B for contactor B145, three poles, without auxiliary contacts and with VC/DC coil. The 4VC/DC voltage is not possible for B500-B contactors. Other voltages available on request. ❸ If predisposed for mechanical latch (G495), the order code becomes 11 B SL.00 ❷ If already fitted with mechanical latch (G495), the order code becomes 11 B L.00 ❷❹. ❹ Indicate rated voltage of the mechanical latch, preceded by the letter C if in DC. vailable voltages are: C 50/60Hz 48 / indicate 110 / 0-40 indicate 0 / V indicate 380 DC 48 / indicate 110 / 0-40V indicate 0. Example: 11 B145L for contactor B145 without auxiliary contacts, with VC/DC coil and mechanical latch powered at 0-40VC. ❺ G495 mechanical latch cannot be mounted. ❻ Complete the order code with the digit of the coil voltage. For VC (50/60Hz) indicate 110 or 0-40VC (50/60Hz) indicate 0. Example: 11 B for contactor B150, three poles, with NO+4NC auxiliary contacts and VC 50/60Hz coil. ❼ Maximum voltage is limited at 300V for UL. For certified type up to 600V, consult Customer Service for information; see contact details on inside front cover. ❽ For voltages 04 / 30 / 400VC 50-60Hz: 10 pieces/package. For all other voltages: 1 piece/package. ❾ Highly conductive auxiliary contact. ❿ For use at this other current value, a 16mm cable, headed with a fork terminal, must be used No UL/CS ratings; data given for indication and reference purposes only. Definite-purpose (DP) contactors are available. Consult Customer Service for information; see contact details on inside front cover. -4 dd-on blocks / ccessories pages -16 to 7 Spare parts pages -8 to 31 pages -3 to 38 Wiring diagrams page -44 pages -48 to 71

6 Three-pole contactors with DC control circuit BG06 D-BG1 D BG09 L BF09 D-BF5 D BF09 L-BF5 L BF6 D-BF38 D BF6 L-BF38 L Three-phase motor control BF50 C-BF110 C B115-B180 B50-B400 Order code IEC operating current Maximum IEC power at 55 C (C3) Maximum UL/CS horsepower ratings DC coil DC coil Ith (C1) Ie (C3) Single phase Three phase 440V Low consumption 40 C 55 C 70 C at 55 C 30V 400V 415V 440V 500V 690V 1000V 10V 40V 00V 40V 480V 600V [] [] [] [] [kw] [kw] [kw] [kw] [kw] [kw] [kw] [HP] [HP] [HP] [HP] [HP] [HP] 11 BG06 01 D❶ / / BG06 10 D❶ ( 60 C) 11 BG09 01 D❶ 11 BG09 01 L❷ / 1 1 / BG09 10 D❶ 11 BG09 10 L❷ ( 60 C) 11 BGF09 01 D❶ 11 BGF09 01 L❷ / 1 1 / BGF09 10 D❶ 11 BGF09 10 L❷ ( 60 C) 11 BGP09 01 D❶ ❽ 4.3❽ 4.5❽ 5❽ 1 / 1 1 / 3 5❽ 11 BGP09 10 D❶ ( 60 C) 11 BG1 01 D❶ / 1 1 / / BG1 10 D❶ 1 ( 60 C) BF09 01 D❶❸ 1 BF09 01 L❷❸ / / BF09 10 D❶❸ 1 BF09 10 L❷❸ 1 BF1 01 D❶❸ 1 BF1 01 L❷❸ / 10 BF1 10 D❶❸ 1 BF1 10 L❷❸ 1 BF18 01 D❶❸ 1 BF18 01 L❷❸ BF18 10 D❶❸ 1 BF18 10 L❷❸ 1 BF5 01 D❶❸ BF5 01 L❷❸ / 7 1 / BF5 10 D❶❸ BF5 10 L❷❸ BF6 00 D❶❸ 1 BF6 00 L❷❸ / 7 1 / 15 0 BF3 00 D❶❸ 1 BF3 00 L❷❸ / BF38 00 D❶❸ BF38 00 L❷❸ 56 (60❿) 45 (48❿)40(4❿) / BF50 C 00❶❸ BF65 C 00❶❸ BF80 C 00❶❸ BF95 C 00❶❸ BF110 C 00❶❸ B115 00❹❺ B145 00❹❺ B180 00❹❺ B50 00❹❺ B310 00❹❼ B400 00❹❺ B500 00❹❺ B630 00❹❺ B ❹❼ For C1/Resisteve duty only, see page -8. ❶ Complete order code with coil voltage digit. For BG09 D 4VDC version complete with built-in surge suppressor, add suffix V10 to the standard order code. The BF09-BF38D types already have a standard supplied built-in TVS (Transient Voltage Suppressor). Standard voltages are as follows: DC 01 / 04 / 048 / 060 / 110 / 15 / 0V. Example: 11 BG06 10 D01 for mini-contactor BG06, three poles, with one NO contact and 1VDC coil. 11 BG09 10 D04 V10 for mini-contactor BG09, three poles, with one NO contact and 4VDC coil, complete with built-in TVS (diode) suppressor. ❷ Low-consumption version. No add-on auxiliary contacts or mechanical interlock can be mounted on BG... type contactors. Complete order code with coil voltage digit. The BF09-BF38L types already have a standard supplied built-in TVS (Transient Voltage Suppressor). Standard voltages are as follows: DC 04 / 048V. Example: 11 BG09 01 L04 for mini-contactor BG09, three poles, with one NC contact and 4VDC low-consumption coil. ❸ Maximum combinations of add-on blocks are given on page ❹ The coil of the contactor can be powered indifferently in C or DC. Complete the order code only with the digit of the coil voltage. Standard voltages are: C/DC 4 / 48 / 60 / (indicate 110) / 0-40 (indicate 0) / (indicate 380) / V (indicate 440). Example: 11 B for contactor B145, three poles, without auxiliary contacts and with VC/DC coil. The 4VC/DC voltage is not possible for B500-B contactors. Other voltages available on request. ❺ If predisposed for mechanical latch (G495), the order code becomes 11 B SL.00 ❹. If already fitted with mechanical latch (G495), the order code becomes 11 B L.00 ❹ ❻. ❻ Indicate rated voltage of the mechanical latch, preceded by the letter C if in DC. Standard voltages are: C 50/60Hz 48 / indicate 110 / 0-40 indicate 0 / V indicate 380 DC 48 / indicate 110 / 0-40V indicate 0. Example: 11 B145L C48 for contactor B145, three poles, without auxiliary contacts, with VC/DC coil and mechanical latch powered at 48VDC. ❼ G495 mechanical latch cannot be mounted. ❽ Maximum voltage is limited at 300V for UL. For certified type up to 600V, consult Customer Service for information; see contact details on inside front cover. ❾ Highly conductive auxiliary contact. ❿ For use at this other current value, a 16mm cable, headed with a fork terminal, must be used. No UL/CS ratings; data given for indication and reference purposes only. Definite-purpose (DP) contactors are available. Consult Customer Service for information; see contact details on inside front cover UL/CS details dd-on blocks / ccessories pages -16 to 7 Spare parts pages -8 to 31 pages -3 to 38 Wiring diagrams page -44 pages -48 to 71

7 Four-pole contactors with C control circuit BG09 T4 BF09 T4-BF18 T4 BF6 T4 -BF38 T4 BF BF80 40 B115 4-B180 4 B50 4-B400 4 Resistive load control Order code IEC operating current Maximum IEC power at 40 C (C1) UL/CS Ith (C1) General C coil 40 C 55 C 70 C 30V 400V 415V 440V 500V 690V 1000V (purpose) use [] [] [] [kw] [kw] [kw] [kw] [kw] [kw] [kw] [] 11 BG09 T4 ❶❿ ( 60 C) BGF09 T4 ❶ ( 60 C) BGP09 T4 ❶ ( 60 C) 8 14❼ 14❼ 15❼ 16❼ 0 BF09 T4 ❶❿ BF1 T4 ❶❿ BF18 T4 ❶❿ BF6 T4 ❶❽❿ BF38 T4 ❶❽ 56 (60❾) 45 (48❾) 40 (4❾) BF50 40❶❿ BF65 40❶❿ BF80 40❶ B ❷❸ B ❷❸ B ❷❸ B ❷❸ B ❷❺ B ❷❸ B ❷❸ B ❷❸ B ❷❺ B ❺❻ No UL/CS 11 B ❺❻ No UL/CS ❶ Complete order code with coil voltage digit or voltage digit followed by 60 if 60Hz. Standard voltages are as follows: -- C 50/60Hz 04 / 048 / 110 / 30 / 400V -- C 60Hz / / / 0 60 / / / (V). Example: 11 BG09 T4 30 for mini-contactor BG09, four poles, with 30VC 50/60Hz coil. 11 BG09 T for mini-contactor BG09, four poles, with 460VC 60Hz coil. ❷ The coil of the contactor can be powered indifferently in C or DC. Complete the order code only with the digit of the coil voltage. Standard voltages are: -- C/DC 4 / 48 / 60 / (indicate 110) / 0-40 (indicate 0) / (indicate 380) / V (indicate 440). Example: 11 B for contactor B145, four poles, without auxiliary contacts and with VC/DC coil. The 4VC/DC voltage is not possible for B500-B contactors. Other voltages available on request. ❸ If predisposed for mechanical latch (G495), the order code becomes 11 B 4SL 00 ❷. If already fitted with mechanical latch (G495), the order code becomes 11 B 4L.00 ❷ ❹. ❹ Indicate rated voltage of the mechanical latch, preceded by the letter C if in DC. Standard voltages are: -- C 50/60Hz 48 / indicate 110 / 0-40 indicate 0 / V indicate DC 48 / indicate 110 / 0-40V indicate 0. Example: 11 B145 4L C0 for contactor B145, four poles, without auxiliary contacts, with VC/DC coil and mechanical latch powered at 0-40VDC. UL/CS details ❺ G495 mechanical latch cannot be mounted. ❻ Complete the order code with the digit of the coil voltage. For VC 50/60 Hz indicate 110 or 0-40VDC 50/60 Hz indicate 0. Example: 11 B for contactor B150, four poles, with NO+4NC auxiliary contacts and VC/DC 50/60Hz coil. ❼ Maximum voltage is limited at 300V for UL. For certified type up to 600V. Consult Customer Service for information; see contact details on inside front cover. ❽ Whenever the BF6 T4 or BF38 T4 types need to be mechanically interlocked with either the BFX50 00 or BFX50 01, the add-on fourth pole of one of the contactors needs to be removed from the right side and fitted on the left side. ❾ For use at this other current value, a 16mm cable, headed with a fork terminal, must be used. ❿ Definite-purpose (DP) contactors are available. Consult Customer Service for information; see contact details on inside front cover. -8 dd-on blocks / ccessories pages -16 to 7 Spare parts pages -8 to 31 pages -3 to 38 Wiring diagrams page -45 pages -48 to 71

8 Four-pole contactors with DC control circuit BG09 T4 D Resistive load control BF09 T4 D-BF18 T4 D BF09 T4 L-BF18 T4 L BF6 T4 D-BF38 T4 D BF6 T4 L-BF38 T4 L BF50C 40-BF80C 40 B115 4-B180 4 B50 4-B400 4 UL/CS details Order code IEC operating current Maximum IEC power at 40 C (C1) UL/CS DC coil DC coil Ith (C1) General Low consumption 40 C 55 C 70 C 30V 400V 415V 440V 500V 690V 1000V (purpose) use [] [] [] [kw] [kw] [kw] [kw] [kw] [kw] [kw] [] 11 BG09 T4 D❶ ( 60 C) BGF09 T4 D❶ ( 60 C) BGP09 T4 D❶ ( 60 C) 8 14❽ 14❽ 15❽ 16❽ 0 BF09 T4 D❶❸ BF09 T4 L❷❸ BF18 T4 D❶❸ BF18 T4 L❷❸ BF6 T4 D❶❸ BF6 T4 L❷❸ BF38 T4 D❶❸ BF38 T4 L❷❸ 56 (60❾) 45 (48❾) 40 (4❾) BF65C 40❶ BF80C 40❶ B ❹❺ B ❹❺ B ❹❺ B ❹❺ B ❹❼ B ❹❺ B ❹❺ B ❹❺ B ❹❼ ❶ Complete order code with coil voltage digit. The BF09-BF38D types already have a standard supplied built-in TVS (Transient Voltage Suppressor). Standard voltages are as follows: DC 01 / 04 / 048 / 060 / 110 / 15 / 0VDC. Example: 11 BG09 T4 D01 for mini-contactor BG09, four poles, with 1VDC coil. ❷ Low consumption version. Complete the order code with coil voltage digit. The BF09-BF38L types already have a standard supplied built-in TVS (Transient Voltage Suppressor). Standard voltages are as follows: DC 04 / 048V Example: BF09 T4 L04 for contactor BF09, four poles, with 4VDC low-consumption coil. ❸ Maximum combinations add-on blocks are page -19. ❹ The coil of the contactor can be powered indifferently in C or DC. Complete the order code only with the digit of the coil voltage. Standard voltages are: -- C/DC 4 / 48 / 60 / indicate 110 / 0-40 indicate 0 / indicate 380 / V indicate 440. Example: 11 B for contactor B145, four poles, without auxiliary contacts and with VC/DC coil. The 4VC/DC voltage is not possible for B500-B contactors. Other voltages available on request. ❺ If predisposed for mechanical latch (G495), the order code becomes 11 B 4SL 00 ❹. If already fitted with mechanical latch (G495), the order code becomes 11 B 4L.00 ❹❻. ❻ Indicate rated voltage of the mechanical latch, preceded by the letter C if in DC. Standard voltages are: C 50/60Hz 48 / indicate 110 / 0-40 indicate 0 / V indicate 380 DC 48 / indicate 110 / 0-40V indicate 0. Example: 11 B145L C48 for contactor B145, four poles, without auxiliary contacts, with VC/DC coil and mechanical latch powered at 48VDC. ❼ G495 mechanical latch cannot be mounted. ❽ Maximum voltage is limited at 300V for UL. For certified type up to 600V consult Customer Service for information; see contact details on inside front cover. ❾ For use at this other current value, a 16mm cable, headed with a fork terminal, must be used. -10 dd-on blocks / ccessories pages -16 to 8 Spare parts pages -8 to 31 pages -3 to 38 Wiring diagrams page -45 pages -48 to 71

9 Four-pole contactors with DC control circuit IEC utilisation current with poles in parallel If the poles of the contactors are arranged in parallel, the operating current is the one indicated in the table multiplied by the K factor given below, which account for the unequal distribution of the current in the various poles. To limit distribution inequality, it is advisable to use paralleling links (see pages -16, -1 and -6). B500 4-B630 4 B UL/CS Fuse Short circuit Type of terminal Incorporated auxiliary Quantity Weight class RMS sym. contacts per 600VC pkg Type / [] [k] UL/CS NO NC n [kg] K5 / 30 5 Clamp-screw K5 / 30 5 Faston K5 / 30 5 Rear PCB solder pin RK5 / 60 5 Clamp-screw RK5 / 80 5 Clamp-screw RK5 / Clamp-screw RK5 / Clamp-screw RK5 / 5 5 Lug-clamp RK5 / 50 5 Lug-clamp RK5 / Screw-nut RK5 / Screw-nut RK5 / Screw-nut L/ Screw-nut L/ Screw-nut L/ Screw-nut L/100 ❿ 18 ❿ Screw-nut L/100 ❿ 18 ❿ Screw-nut L/1500 ❿ 18 ❿ Screw-nut ❿ No UL/CS ratings; data given for indication and reference purposes only. ❷ 11 IEC/EN designation: Pillar terminal. POLES in parallel: K = POLES in parallel: K =. 4 POLES in parallel: K =.8 Certifications and compliance Certifications obtained: UL UL R C E C I Canada S C N Type US US C C BG09 T4 D BGF09 T4 D BGP09 T4 D❼ BF09 T4 D - BF09 T4 L BF18 T4 D - BF18 T4 L BF6 T4 D - BF6 T4 L BF38 T4 D - BF38 T4 L BF65 C 40 BF80 C 40 B115 4 B145 4 B180 4 B50 4 B310 4 B400 4 B500 4 B630 4 B Certified products. UL CS - UL Listed, for US and Canada (culus File E9360) for BG BF110 types indicated, as Motor Controllers Contactors, except for BGP09 types which are UL Recognized, for US and Canada ( File E9360 Component). Products having this type of marking are intended for use as components of complete workshop-assembled equipment. BGP is UL rated up to 300V; for type with rating up to 600V, consult Customer Service for information see contact details on inside front cover. UL Listed for US only (File E9360) for B115 B400 types indicated, as Motor Controllers Contactors. UL Listed for US and Canada (culus - File E17185) for B B and B500 4SL... B630 4SL types as Industrial Control Switches. - BF09 BF95 and B115 B400 contactors are also CS certified, for Canada only (File 5433). In addition, BF1, BF5, BF38 and BF65 types are CS certified as Elevator Equipment (File 5433, class 411). See technical characteristics on page -63 for BF1-BF38 and page -65 for BF65. Compliant with standards: IEC/EN , IEC/EN , UL508, CS C. n 14 for all types; UL , UL , CS C. n , CS C. n for B B Plastic materials are compliant with standards IEC/EN 60335; for all BF09 BF38 versions only, add suffix V60 to the standard product order code. Example: BF09 T4 D04 V60 for BF09, four poles, 4VDC coil with compliant plastic materials). dd-on blocks / ccessories pages -16 to 7 Spare parts pages -8 to 31 pages -3 to 38 Wiring diagrams page -45 pages -48 to 71-11

10 Four-pole contactors with control circuit: C and DC Mini-contactor four power poles, NO and NC BG series 11 BG09 T... Order code IEC rated conventional Qty Wt free air thermal current Ith per pkg 40 C 55 C 60 C [] [] [] n [kg] C COIL. Terminals: clamp screw. 11 BG09 T ❶ DC COIL. Terminals: clamp screw. 11 BG09 T D❷ NOTE: No coil change or replacement is possible. Operational characteristics Type UL/CS Protection fuse Conductor General use IEC gg UL K5 section [] [] [] [mm ] [WG] BG09...T Certifications and compliance Certifications obtained: CCC, EC; UL Listed, for US and Canada (culus - File E9360), as Motor Controllers - Contactors. Compliant with standards: IEC/EN , IEC/EN , UL508, CS C. n 14. Contactors four power poles, NO and NC BF series BF09 T... Order code IEC rated conventional Qty Wt free air thermal current Ith per 40 C 55 C 60 C pkg [] [] [] n [kg] C COIL. Terminals: clamp screw. BF09 T ❶ BF18 T ❶ BF6 T ❶ BF38 T ❶ 56 (60❺) 45 (48❺) 40 (4❺) DC COIL. Terminals: clamp screw. BF18 T D❷❹ BF6 T D❷❹ BF38 T D❷❹ 56 (60❺) 45 (48❺) 40 (4❺) DC COIL. Low consumption (.4W). Terminals: clamp screw. BF18 T L❸❹ BF6 T L❸❹ BF38 T L❸❹ 56 (60❺) 45 (48❺) 40 (4❺) Operational characteristics Type UL/CS Protection fuse Conductor General use IEC gg ULRK5 section [] [] [] [mm ] [WG] BF09 T BF18 T BF6 T BF38 T Certifications and compliance Certifications obtained: EC, CCC, RIN; UL Listed for US and Canada (culus - File E9360) and CS certified for Canada (File 5433), as Motor Controllers - Contactors. Compliant with standards: IEC/EN , IEC/EN , UL508, CS C. n 14. Plastic materials are compliant with standards IEC/EN 60335; for all BF09 BF38 versions only, add suffix V60 to the standard product order code. Example: BF09 T 30 V60 for BF09, NO+NC main poles, 30V 50/60Hz coil with compliant plastic materials). ❶ Complete with coil voltage digit if 50/60Hz or with voltage digit followed by 60 if 60Hz. Standard voltages are: C 50/60Hz 04 / 048 /110 / 30 / 400V C 60Hz / / / 0 60 / / / (V). Example: 11 BG09 T 30 for mini-contactor BG09 T, poles NO and poles NC, with 30VC 50/60Hz coil. 11 BG09 T for mini-contactor BG09 T, poles NO and poles NC, with 460VC 60Hz coil. ❷ Complete with coil voltage digit. The BF18-BF6-BF38 TD types already have a standard supplied built-in TVS (Transient Voltage Suppressor). Standard voltages are: DC 01 / 04 / 048 / 060 / 110 / 15 / 0V. Example: 11 BG09 T D01 for mini-contactor BG09 T, poles NO and poles NC, with 1VDC coil. ❸ Low-consumption version. Complete the order code with coil voltage digit. The BF18-BF6-BF38 TL types already have a standard supplied built-in TVS (Transient Voltage Suppressor). Standard voltages are as follows: DC 04 / 048V. Example: BF18 T L04 for contactor BF18 T, poles NO and poles NC, with 4VDC low-consumption coil. ❹ Maximum combinations of add-on blocks are given on page -19. ❺ For use at this other current value, a 16mm cable, headed with a fork terminal, must be used. -1 dd-on blocks / ccessories pages -16 to 5 Spare parts pages -8 to 31 page -3 and 33 Wiring diagrams page -45 pages -48 to 65

11 Four-pole contactors with control circuit: C and DC Contactors four power poles, 4 NC BF series BF18 T0... Order code IEC rated conventional Qty Wt free air thermal current Ith per 40 C 55 C 60 C pkg [] [] [] n [kg] C COIL. Terminals: clamp screw. BF18 T0 ❶ BF6 T0 ❶ DC COIL. Terminals: clamp screw. BF18 T0 D❷❹ BF6 T0 D❷❹ DC COIL. Low consumption (.4W). Terminals: clamp screw. BF18 T0 L❸❹ Operational characteristics Type UL/CS Protection fuse Conductor General use IEC gg ULRK5 section [] [] [] [mm ] [WG] BF18 T BF6 T Certifications and compliance Certifications obtained: EC, CCC, RIN; UL Listed for US and Canada (culus - File E9360) and CS certified for Canada (File 5433), as Motor Controllers - Contactors. Compliant with standards: IEC/EN , IEC/EN , UL508, CS C. n 14. Plastic materials are compliant with standards IEC/EN 60335; for BF18 and BF6 versions only, add suffix V60 to the standard product order code. Example: BF18 T0 30 V60 for BF18, four NC main poles, 30VC 50/60Hz coil with compliant plastic materials). NOTE: The BF18-BF6 T0D and BF18 T0L types have a standard supplied built-in TVS (Transient Voltage Suppressor). Contators four NO power poles to connect in series for photovoltaic applications BF series BFD Order IEC rated operational Qty Wt code current in DC1 55 C per pkg [] n [kg] C COIL. Terminals: lug clamp (IEC pillar terminal). 11BFD80 40❶ DC COIL. Terminals: lug clamp (IEC pillar terminal). 11BFD80 C 40❷ ❶ Complete with coil voltage digit if 50/60Hz or with voltage digit followed by 60 if 60Hz. Standard voltages are: C 50/60Hz 04 / 048 /110 / 30 / 400V C 60Hz / / / 0 60 / / / (V). Example: BF18 T0 30 for contactor BF18 T0, 4 NC power poles, with 30VC 50/60Hz. 11 BFD for contactor BFD80 40, 4 NO power poles, with 4VC 50/60Hz for photovoltaic application. ❷ Complete with coil voltage digit. Standard voltages are: DC 01 / 04 / 048 / 060 / 110 / 15 / 0V. Example: BF18 T0 D01 for contactor BF18 T0, 4 NC power poles, with 1VDC coil. ❸ Low-consumption version. Complete the order code with coil voltage digit. Standard voltages are as follows: DC 04 / 048V. Example: BF18 T0 L04 for contactor BF18 T0, 4 NC power poles, with 4VDC low-consumption coil. ❹ Maximum combinations of add-on blocks are given on page -19. ❺ For use at this other current value, a 16mm cable, headed with a fork terminal, must be used. General characteristics The contactors are specifically made with magnetic elements in the arc extinction chambers to obtain high DC load operational capabilities. They are used to disconnect and isolate the load between the photovoltaic panel and the C/DC inverter. For add-on contact blocks, accessories and spare parts, consider indications of the corresponding standard BF80 types (11BF80 40 and 11 BF80C 40 ). Italian Fire Department Directives These directives provide for an disconnecting device for all current-carrying elements, that can be operated by remote control switch, placed in an easily reached and marked position, in order to safely isolate each part of the installation within the fire system compartment including the photovoltaic (PV) generator. s an alternative, the PV generator must be installed, either externally of the fire system compartment or internally but in a dedicated compartment with adequate fire-resistant features. For such function, specifically designed contactors for on-load use in IEC DC1 duty up to 1000VDC are available. Operational characteristics Use in IEC DC1 duty Type IEC operational voltage Ue 400V 600V 800V 1000V IEC max current Ie in DC1 with L/R 1ms with 4 poles in series [] [] [] [] BFD Wiring scheme 4 poles Compliant with standards: IEC/EN , IEC IEC/EN dd-on blocks / ccessories pages -18 to 5 Spare parts pages -8 to 31 page -3 and 33 Wiring diagrams page -45 pages -48 to 67-13

12 dd-on blocks and accessories for BF series contactors dd-on blocks BFX G BFX G G G48 11 G G G G G18 BFX1... Order code Characteristics❼ Max Qty Wt qty per per contactor pkg n n [kg] uxiliary contacts with front centre mounting❷. Screw terminals. BFX10 0❶ NC BFX10 11❶ 1NO + 1NC BFX10 0❶ NO G484 03❶ 3NC G484 1❶ 1NO + NC G484 1❶ NO + 1NC G484 30❶ 3NO BFX NC BFX NO + 3NC BFX10 NO + NC BFX NO + 1NC BFX NO BFX NO+1NC and 1 5 0,048 1EM+1LB (1 early make+1 late break) uxiliary contacts for front lateral mounting. Screw terminals❹. 11 G NC G418 01D 1LB (late break) G NO G EM (early make) uxiliary contacts for front lateral mounting. Faston terminals❺. 11 G18 1NO or 1NC reversible G481 0 NC G NO + 1NC G481 0 NO G48❷❸ Changeover contact dapter for auxiliary contact side mounting. 11 G80 for G G419 for G G483 for G481 and G uxiliary contacts for side mounting. Screw terminals. BFX1 0❷ NC for BF00, BF09-BF38 BFX1 11❷ 1NO+1NC for BF00, BF09-BF38 BFX1 0❷ NO for BF00, BF09-BF38 11 G NC G48 01D 1LB (late break) G NO G EM (early make) Delayed auxiliary contacts 1NO + 1NC (pneumatic operation) on energisation for front centre mounting ❶❻. Screw terminals. 11 G s G s G s G s G s G s Delayed auxiliary contacts 1NO + 1NC (pneumatic operation) on de-energisation for front centre mounting ❶❻. Screw terminals. 11 G s G s G s G s G s G s G ms Operational characteristics for add-on auxiliary contacts Type G418❹ G484 G18❺ G48❸ G48❹ BFX10 G481❺ G485❻ BFX1 G486❻ G487❻ IEC conventional free ❸ air thermal current Ith IEC rated insulation V voltage Ui Terminals: Screw M3.5 M3 Width mm 7 7 Faston mm 1x6.35 1x6.35 x.8 x.8 Tightening torque Nm lbin Conductor section maximum with 1 or cables flexible w/o lug mm.5.5 flexible c/w lug mm WG n Terminal protection IP0 IP0 IP0❺ IP0❸ per IEC/EN 6059 ❹❻ UL/CS and C IEC/EN designation DC P600❹ Q600 P600 P600 Mechanical life cycles 10❻ (million) SM1 breaker - contactor connecting kits See page 1-5. Maximum assembly combination of add-on blocks See pages - to -5. Positive (force) guided contacts see page -57. Certifications and compliance Certifications obtained: Type culus CS EC CCC BFX10... BFX1... G18 G418..., G48... G G48 G G G G Certified products; pending for BFX UL Recognized for US only (File E93601) as uxiliary Devices - Component. Products having this type of marking are intended for use as components of complete workshop-assembled equipment. culus - UL Listed for US and Canada (culus - File E93601) as uxiliary Devices. CS - CS certified for Canada only (File 5433) as uxiliary Devices for motor controllers. dd-on auxiliary contacts are compliant with the following standards: IEC/EN , IEC/EN , UL508, CS C. n 14. ❶ The contacts can also be fitted on B type contactors using the adapter G358. See pages -6 and -7. ❷ Highly conductive contacts. ❸ Gold-plated contacts inside tight casing for use in pollutant environments. The Ith value refers to 15VC and 30VDC. IEC IP0 protection is warranted to equipment wired with insulated Faston terminals. ❹ IEC IP0 protection is warranted to equipment wired with minimum 0.75mm² conductor section. Designation in DC is Q600 for these types. ❺ IEC IP0 protection is warranted to equipment wired with insulated Faston terminals. ❻ For particularly severe ambient conditions, consult Customer Service for information; see contact details on inside front cover. IEC IP0 protection is warranted to equipment wired with minimum 1mm² conductor section. Mechanical life is 3 million cycles. ❼ ll contacts are each SPST except G48 which is SPDT. -18 page -40 Wiring diagrams pages -46 and 47 pages -48 to 65

13 dd-on blocks and accessories for BF series contactors BF00, BF09 -BF110, BF50C-BF110C Maximum assembly combination for alternating-current contactors BF00, BF09 -BF110 Maximum assembly combination for direct-current contactors BF50 C-BF110 C Front centre mount Front lateral mount Side mount Contactors BFX10 0 BFX10 04 G G...❹ BFX50 0 G69 G G48... BFX1 0 BFX10 11 BFX10 13 G G7...❹ BFX50 03 G18 G419+ BFX1 11 ❶ G G BFX10 0 BFX10 G487 G48 G80+ BFX1 0 G18 BFX10 31 G483+ BFX type G ❸ BFX10 40 only of: G483+ BFX50 01 G G48 ❸ G319 5 G3... n of blocks n of blocks n of blocks n of blocks n of blocks n of blocks 1 type only 1 type only Control relay BF ❺ 1 ❶ 1 or ❶ 1 or ❶ 1 ❸ Three poles BF09 -BF ❺ 1 ❶ 1 or ❶ 1 or ❶ 1 ❸ BF6 -BF ❺ 1 ❶ 1 or ❶ 1 or ❶ 1 ❸ BF50-BF ❻ 1 1 or ❶ BF50 C-BF110 C ❻ 1 1 or Four poles BF09 -BF ❺ 1 ❶ 1 or 1 or ❶ 1 ❸ BF6 -BF ❺ 1 ❶❷ 1 ❶ 1 or ❶ 1 ❸ BF50-BF ❻ 1 1 or BF65 C-BF80 C ❻ 1 1 or ❶ Mounting of BFX50 03 interlock is not possible when BFX10... block with 4 contacts and/or G latch are mounted. ❷ To fit the mechanical interlock, the add-on fourth pole needs to be mounted on the left side of the one of the contactors. ❸ One only side-mount block can be fitted on each contactor whenever the BFX interlock is mounted. ❹ One BFX10... or delayed G48... contact block can be mounted on the G or G7 mechanical latch. ❺ G mechanical latch. ❻ G7 mechanical latch. BF00 D, BF09 D-BF38 D, BF00 L, BF09 L-BF38 L OR + Maximum assembly combination for direct-current contactors BF00 D, BF09 D-BF38 D Maximum assembly combination for direct-current contactors BF00 L, BF09 L-BF38 L OR Front centre mount Front lateral Side mount mount OR OR Contactors BFX10... BFX10... G G... 1 type only BFX50... BFX G ❹ ❸ G487 ❶ n of blocks n of blocks n of blocks 1 type only 1 type only Control relay BF00 D BF00 L Three poles BF09 D-BF5 D BF6 D-BF38 D BF09 L-BF5 L BF6 L-BF38 L Four poles BF09 D-BF5 D BF6 D-BF38 D 1 1 1❼ BF09 L-BF5 L BF6 L-BF38 L 1 1❼ 1❼ ❶ Mounting of BFX50 03 interlock is not possible when BFX10... block with 4 contacts and/or G latch are mounted. ❸ One only side-mount block can be fitted on each contactor whenever the BFX interlock is mounted. ❹ One BFX10... or delayed G48... contact block can be mounted on the G or G7 mechanical latch. ❼ To fit the mechanical interlock, the add-on fourth pole needs to be mounted on the left side of the one of the contactors. For other assembly combination, consult Customer Service; see contact details on inside front cover. OR + page -40 Wiring diagrams pages -46 and 47 pages -48 to 67-19

14 dd-on blocks and accessories for BF series contactors dd-on blocks BFX4 BFXD4 BFX50 00 BFX50 01 BFX50 0 BFX G69 11 G G7... BFX77... BFX G G G G G RE44 Order code Characteristics Max Qty Wt qty per per contactor pkg n n [kg] Fourth pole. BFX4 For BF6 -BF and BF38 BFXD4 For BF6 D-BF3 D BF38 D-BF6 L- BF3 L - BF38L Mechanical interlock. BFX50 00❶ Side mount for BF00, BF09-BF38 BFX50 01❶ Side mount with NC contacts for BF00, BF09-BF38 BFX50 0 Front mount, low profile for BF00, BF09-BF38 BFX50 03 Front mount for BF00, BF09-BF38 BFX89 10 Spacer for interlocking BF09-BF38 C/DC contactors 11 G69 Front mount for BF50-BF110 Mechanical latch. Screw terminals. 11 G❷ For BF00, BF09-BF G7❷ For BF50-BF Manual closing mechanism. 11 G454 For BF00, BF09-BF G455 For BF50-BF Quick connect surge suppressors for BF00, BF09-BF38 C contactors. BFX VC/DC (Varistor) BFX VC (Varistor) BFX VC (Varistor) BFX VC (Resistor-Capacitor) BFX VC (Resistor-Capacitor) BFX VC (Resistor-Capacitor) BFX VC (Resistor-Capacitor) Surge suppressor for BF50-BF110 contactors, front mount. Faston terminals. 11 G VC/DC (Varistor) G VC/DC (Varistor) G VC/DC (Varistor) G VC/DC (Varistor) G VDC (Diode) G VC (Resistor-Capacitor) G VC (Resistor-Capacitor) G VC (Resistor-Capacitor) Suppressor mounting adapter for G318-G319-G3. 11 RE44 For 35mm DIN rail (IEC/EN 60715) ❶ Different sized contactors can be interlocked. Example: BF09-BF5 with BF6-BF38. BFX50 01 contacts are each SPST. ❷ Replace with the digit of the voltage if 50 or 60Hz and with the letter C followed by the digit of the voltage if DC. Standard voltages are: 50/60Hz 4 / 48 / indicate 110 / 0-40 indicate 0 / V indicate 380. DC 1 / 4 / 48 / indicate 110 / 0-40V indicate 0. Operational characteristics Type BFX4 BFX50 01 BFXD4 IEC conventinal free air thermal current Ith IEC rated insulation voltage Ui V Terminals: Screw M4 M3 Width mm Tightening torque Nm lbin Conductor section Maximum with 1 or cables flexible w/o lug mm 16.5 flexible c/w lug mm 16.5 WG n 6 14 Terminal protection IP0❸ IP0 per IEC/EN 6059 UL/CS and C 600 IEC/EN designation DC Q600 Mechanical life (million) cycles Type G G7 Rated control circuit voltage C (50/60 Hz) V DC V Power consumption with control C V DC W Minimum energising drop-out ms pick-up ms Tightening torque Nm lbin Conductor section Maximum with 1 or cables flexible w/o lug mm 4 4 flexible c/w lug mm.5.5 WG n ❸ The condition is front IP0 protection. Maximum assembly combination of add-on blocks See page -19, - to -5. Positive (force) guided contacts See page -57 for BFX5001. Certifications and compliance Certifications obtained: Type culus CS EC BFX4 - BFXD4 BFX50... BFX77... BFX79... G69 G... G7... Certified products. - UL Recognized for US only (File E93601) as uxiliary Devices Component. Products having this type of marking are intended for use as components of complete workshop-assembled equipment. culus - UL Listed for US and Canada (culus - File E9360) as Magnetic motor controllers. CS - CS certified for Canada only (File 5433) as uxiliary Devices for motor controllers. Compliant with standards: IEC/EN , IEC/EN , UL508, CS C. n pages -40 and 41 Wiring diagrams page -47 pages -48 to 67

15 ccessories for BF series contactors ccessories BFX31... BFX3... BFX 80 BFX89 01 BFX G65 11 B B35 11 G31 11 G3 11 B G85 Order code Characteristics Qty Wt per pkg n [kg] Rigid connecting kits for three-pole reversing contactor assembly. BFX31 01 For contactors BF09 - BF5 side by side with BFX50 0 or BFX50 03 interlock BFX31 0 For contactors BF09 - BF5 side by side with BFX50 00 or BFX50 01 interlock BFX3 01 For contactors BF6 - BF38 side by side with BFX50... interlock Rigid connecting kits for star-delta starters. BFX31 31 For contactors BF09-BF (line-star-delta) BFX3 31 For contactors BF6-BF (line-star-delta) BFX3 3 For contactors BF6-BF (line-delta) and BF09-BF5 (star) Sealing cover. BFX80 For contactors BF00, BF09-BF38 Screw fixing adapters for contactors. BFX89 01 Universal base to screw fix BF09-BF38 contactors BFX89 0 Screw fixing brackets for BF09-BF38 contactors Power terminal shroud. 11 G65❶ IP0 protection for 3-pole BF50 to BF110 types Paralleling links. 11 B135 poles for BF09-BF5 types B35 poles for BF6-BF38 types B435 3 poles for BF50-BF110 types One-pole enlarged terminals. 11 G mm for BF09-BF5 types G mm for BF6-BF38 types Three-pole enlarged terminals. 11 G mm for BF50-BF types❷ Four-pole enlarged terminals. 11 G88 1x50mm for contactors BF50-BF110 types❷ uxiliary terminal. 11 G85 For BF50-BF110 types Marking element for BF00, BF09-BF110 contactors. BFX30 Blank label for writing ❶ For 3-pole contactors, BF50-BF110 types only. N.B. Two pieces are required per contactor. ❷ n additional 1-50mm conductor can be fitted in the contactor terminal. Operational characteristics of enlarged and auxiliary terminals Type G31 G3 G85 G71 G88 Tightening Nm torque lbin Tool Type PH1 PH PH1 Metric llen 4 Certifications and compliance Certifications obtained: GOST for all; UL Listed, for US and Canada (culus - File E9360), under Magnetic Motor Controllers for BFX31 01, BFX31 0, BFX3 01, BFX31 31, BFX3 31 and BFX3 3 as rigid kits, G71 and G88 as enlarged terminal kits. Compliant with standards: IEC/EN , UL508, CS C. n G71 11 G88 pages -40 and 41 Wiring diagrams page -47 page -48 to 67-1

16 dd-on blocks and accessories for BF series contactors dd-on blocks for C contactors Combinations: Mounting position on BF00 and BF09 -BF110 contactors Table with combinations: See page -19. G G G487 G...❷ G7... G454 ❸ (for contactors BF00, BF09 -BF38 ) G455 ❸ (for contactors BF50-BF110) BFX10...❷ G BFX10... G BFX50 00 BFX50 01 BFX77... BFX79... BF00 BF09 -BF110 G18 G G48 BFX1... G419❶ G80❶ ❶ BFX50 0 (for contactors BF00, BF09 -BF38 ) G418...❶ G483❶ G48...❶ BFX50 03 (for contactors BF00, BF09 -BF38 ) G18❶ G481...❶ G48❶ ❶ Mounting not possible if front lateral contacts or mechanical interlock BFX50 00 or BFX50 01 are mounted. ❷ If the G latch is mounted, no front lateral contacts can be fitted on contactors BF00 and BF09 to BF38. ❸ No add-on block can be mounted on front when the manual closing mechanism G454 or G455 is fitted. G69 (for contactors BF50-BF110) Combinations: Mounting position on BF00 and BF09 -BF38 contactors with mechanical latch G fitted Table with combinations: See page -19. G G G487 BFX10... G BFX10... Combinations: Mounting position on BF50-BF110 contactors with mechanical latch G7 fitted Table with combinations: See page -19. BFX10... BFX10... G G G G487 BF50-BF110 G BFX77... BFX79... BF00 BF09 -BF38 G G7 G18 G G48 G G G3... G G69 BFX50 00 BFX50 01 BFX1... G18 G G48 ❹ Mounting not possible if front lateral contacts are fitted. - pages -40 and 41 Wiring diagrams pages -46 and 47 pages -48 to 67

17 dd-on blocks and accessories for BF series contactors dd-on blocks for DC and DC low consumption contactors Combinations: Mounting position on BF00 and BF09-BF38, D and L versions Table with combinations: See page -19. BFX10... G G G487 BFX10... G...❷ G454❸ BF00 D BF09 D-BF38 D BF00 L BF09 L-BF38 L❷ BFX50 0 BFX50 00 BFX50 01 BFX1... BFX50 03❶ ❶ Mounting not possible when the G mechanical latch is fitted. ❷ The G mechanical latch cannot be fitted on BF6 L - BF38 L four-pole types. ❸ No add-on block can be mounted on front when the G454 manual closing mechanism is fitted. Combinations: Mounting position on BF50 C - BF110 C contactors with G7 mechanical latch fitted Table with combinations: See page -19. G G G487 BFX10... G BFX10... G BF50 C-BF110 C G7 G18 G G48 G G G3... G G69 G18 G G48 ❹ No add-on block can be mounted on front when the G455 manual closing mechanism is fitted. ❺ Mounting not possible if front lateral contacts are fitted. pages -40 and 41 Wiring diagrams pages -46 and 47 pages -48 to 67-3

18 dd-on blocks and accessories for BF series contactors ccessories for C, DC and DC low consumption contactors Combinations G71 B435 G65 G85 B35 G3 G31 B135 BF50-BF110 BF6-BF38 BF00 BF09-BF5 BFX80 Cable 6-50mm Plate.5x9mm (max) BF50-BF110-4 page -41 pages -48 to 67

19 dd-on blocks and accessories for BF series contactors ccessories for C, DC and DC low consumption contactors Rigid reversing contactor assembly connecting kits for BF09-BF5 contactors with BFX50 0 or BFX50 03 mechanical interlock BFX50 0 BFX50 03 BFX31 01 Rigid reversing contactor assembly connecting kits for BF09-BF5 contactors with BFX50 00 or BFX50 01 mechanical interlock BFX31 0 BFX50 0 BFX50 03 BFX31 01 BFX31 0 BFX50 00 BFX50 01 RF38 RF38 Rigid reversing contactor assembly connecting kits for BF6-BF38 contactors with BFX50 0 or BFX50 03 mechanical interlock Rigid star-delta starter assembly connecting kits for BF09-BF5 contactors BFX3 01 BFX50 0 BFX31 31 BFX50 0 BFX50 03 BFX3 01 RF38 BFX50 00 BFX50 01 RF38 BFX31 31 Rigid star-delta starter assembly connecting kits for BF6-BF38 contactors BFX3 31 Rigid star-delta starter assembly connecting kits for BF6-BF38 (line-delta) and BF09-BF5 (star) contactors BFX3 3 BFX3 31 BFX3 3 RF38 RF38 pages -40 and 41 Wiring diagrams page -47 pages -48 to 67-5

20 Spare parts for BF series contactors C coils BFX91... BFX B Order code Rated frequency Qty Wt and voltage per pkg [Hz] [V] n [kg] For contactors BF00 -BF09 -BF1 -BF18 -BF5 BFX91 04❶ 50/60 4VC BFX91 048❶ 48VC BFX91 110❶ 110VC BFX91 30❶ 30VC BFX91 400❶ 400VC BFX ❶ 60 4VC BFX ❶ 48VC BFX ❶ 10VC BFX ❶ 0VC BFX ❶ 30VC BFX ❶ 460VC BFX ❶ 575VC For contactors BF6 -BF3 -BF38. BFX9 04❶ 50/60 4VC BFX9 048❶ 48VC BFX9 110❶ 110VC BFX9 30❶ 30VC BFX9 400❶ 400VC BFX ❶ 60 4VC BFX ❶ 48VC BFX ❶ 10VC BFX9 0 60❶ 0VC BFX ❶ 30VC BFX ❶ 460VC BFX ❶ 575VC For BF50-BF65-BF80-BF95-BF110 contactors. 11 B /60 4VC B VC B VC B VC B VC B VC B VC B VC B VC B VC B VC B VC ❶ Four-terminal coil. Operational characteristics for BFX91 or BFX9 coils C control Rated voltage at 50/60, 60Hz V Operating voltage limits 50/60Hz coil 50Hz pick-up % Us powered at drop-out % Us Hz pick-up % Us drop-out % Us Hz coil 60Hz pick-up % Us powered at drop-out % Us 0-55 verage coil consumption at 0 C 50/60Hz coil 50Hz in-rush V 75 powered at holding V 9 60Hz in-rush V 70 holding V Hz coil 60Hz in-rush V 75 powered at holding V 9 Dissipation at 50Hz W.5 Operational characteristics for B705 coil C control Rated voltage at 50/60, 60Hz V Operating voltage limits 50/60Hz coil 50Hz pick-up % Us powered at drop-out % Us Hz pick-up % Us drop-out % Us Hz coil 60Hz pick-up % Us powered at drop-out % Us 0-55 verage coil consumption at 0 C 50/60Hz coil 50Hz in-rush V 0 powered at holding V 18 60Hz in-rush V 00 holding V 15 60Hz coil 60Hz in-rush V 0 powered at holding V 18 Dissipation at 50Hz W 6 Materials Class F enamelled copper wire. Special versions For coils with non standard voltages, consult Customer Service for information; see contact details on inside front cover. -8

21 Spare parts for BF series contactors DC coils Order code Rated Qty Wt 11 B voltage per pkg [V] n [kg] For BF50 C-BF110 C contactors. 11 B VDC B VDC B VDC B VDC B VDC B VDC B VDC NOTE: No coil replacement for contactors BF00 D, BF09 D-BF38 D, BF00 L, BF09 L-BF38 L, is possible. Operational characteristics for B911 coil DC control Rated voltage V Operating limits pick-up % Us drop-out % Us 10-5 verage dissipation 0 C W 15 in-rush/holding Materials Class F enamelled copper wire. Special versions For coils with non standard voltages, consult Customer Service for information; see contact details on inside front cover. -9

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors... Three-pole versions up to 630A in IEC AC3 duty Four-pole versions up to 1600A in IEC AC1 duty Versions for power factor correction up to 100kvar at 400VAC Four-pole versions with NO+NC or 4NC main poles

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Definite purpose contactors

Definite purpose contactors Definite purpose contactors Three-pole and four-pole non-reversing DP contactors 600VAC T4 DPBF09 - DPBF12 - DPBF18 - DPBF09 T4 - DPBF12 T4 - DPBF18 T4 DPBF26A DPBF32A DPBF50 DPBF80 Motor Locked Rotor

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

Contactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors.

Contactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors. Contactors E Line contactors. E Line contactors. xstart series contactors.3 xstart C series contactors.4 D Line contactors xstart series contactors xstart C series contactors D Line contactors X UTOMTION

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

Series CA6 Contactors

Series CA6 Contactors Series C6 Contactors classic contactor for demanding applications from 75 to 600HP (@460V) - 100 to 700HP (@ 575V) This series is being replaced by the C9 Series of contactors Sprecher + Schuh s C6 contactor

More information

Fuse holders and fuses

Fuse holders and fuses Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Contactors. 1.1 E Line contactors Control relays XTRG... 1 Contactors XTCG... 4

Contactors. 1.1 E Line contactors Control relays XTRG... 1 Contactors XTCG... 4 Contactors E Line contactors xstart series contactors. E Line contactors Control relays XTRG....................................................... Contactors XTCG.........................................................

More information

Manual Motor Protectors

Manual Motor Protectors 88 Manual Motor Protectors 51 30 UP TO IMM16 Frame IMM32 Frame IMM65 Frame E468295 E468295 High interrupt capacity up to 100k (with optional current limiter) Din rail mounting Lockable handle (OFF position)

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Series C8 Miniature and Starters... 3 ccessories... 2 Contactor Cross

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC. Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9

More information

Series CA5 Contactors

Series CA5 Contactors Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Products and solutions for photovoltaic applications

Products and solutions for photovoltaic applications Products and solutions for photovoltaic applications Components for string and interface control panels Switch disconnectors Surge protection devices Fuse holders The range of LOVATO Electric components

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Technical Information

Technical Information Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Leadership driven by innovation

Leadership driven by innovation s Leadership driven by innovation Our innovations are your solutions for enhanced productivity LV Switchgear Motor Control Products Maximum etail Price w.e.f. 23 rd September, 203 Index Contents 2 Page

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

Controls. CONTACTORS CWB Line (up to 40A)

Controls. CONTACTORS CWB Line (up to 40A) Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Ambient temperature compensation (-40F to +1400F) Phase loss sensitivity protection, Current unbalance sensitivity.

Ambient temperature compensation (-40F to +1400F) Phase loss sensitivity protection, Current unbalance sensitivity. www.we.net Thermal Overload Relays - RW Series Rated for the new industry RW overload relays are an important part of WEG rane of products. s usual in WEG products, an extended operational service life

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

Electrical sector solutions E Line family. Industry leading design in a compact package

Electrical sector solutions E Line family. Industry leading design in a compact package Electrical sector solutions E Line family Industry leading design in a compact package The power of fusion. 87 88 89 899 90 908 9 9 9 9 97 97 977 98 98 989 999 There s a certain energy at Eaton. It s the

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en Connect - Contact - Control 3 Contactors CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en 2 CL1115/02, CL1215/02, CL1315/02 1, 2 and 3

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

SWITCH DISCONNECTORS PLANET -SWITCH.

SWITCH DISCONNECTORS PLANET -SWITCH. SWITCH DISCONNECTORS 6A to 600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 50A. PLANET -SWITCH SEC. PAGE

More information

Electrical sector solutions E Line family. Industry leading design in a compact package

Electrical sector solutions E Line family. Industry leading design in a compact package Electrical sector solutions E Line family Industry leading design in a compact package Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

4.1. Definite Purpose Contactors and Starters. Contents

4.1. Definite Purpose Contactors and Starters. Contents . Definite Purpose and Starters Product Overview and Starters Definite Purpose and Starters Contents Description Page 20 0A, Compact Single- and Two-Pole C25................................ V5-T- 5 360A,

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com TeSys D, K Catalogue 2017 'S335' series contactors for electrodomestic applications schneider-electric.com Presentation TeSys D, TeSys K TeSys D, TeSys K: S335 series Best-in-class contactors for electrodomestic

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator 4 Safety switches with and separate Selection diagram VF KEYF20 VF KEYF21 VF KEYF22 VF KEYF28 CTUTORS HED TYPE ND WORKING PRINCIPE D locked with de-energized E locked with energized SIGNING ED B Z two

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Contactors. CT1115/04, CT1130/04 CT1215/04, CT1230/04 CT1315/04, CT1330/04 1, 2 and 3 pole power contactors for AC and DC Catalogue C20.

Contactors. CT1115/04, CT1130/04 CT1215/04, CT1230/04 CT1315/04, CT1330/04 1, 2 and 3 pole power contactors for AC and DC Catalogue C20. Connect - Contact - Control Contactors CT5/0, CT0/0 CT5/0, CT0/0 CT5/0, CT0/0, and pole power contactors for AC and DC Catalogue C0.en Power contactors for AC and DC, Series CT Owing to a new blowout technology,

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose Contactors General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Contactors Series C8 Miniature Contactors and Starters... 3

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4JL D4JL For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. uard Lock Safety-Door Switch Holding

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors .2 Definite Purpose and Starters 5 360, Two-, Three- and Four-Pole 25 5 360, Two-, Three- and Four-Pole 25 Product Description Eaton offers the most comprehensive line of definite purpose contactors in

More information

Overview. Contents. Overview

Overview. Contents. Overview 1/0 Overview 1 Contents Overview 3-pole Block Contactors and Motor Protection... 1/ 4-pole Block Contactors... 1/3 Contactors for Specific Applications... 1/4 Mini Contactors and Motor Protection... 1/

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors Industrial Switchgear New Products Catalogue 2007 4 Pole Switching with the The complete range of contactors, efficient motorstarters and variable speed drives for the motor circuit. New simple to install

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Deliveryprogram Contactorrelay,2N/O+2N/C,DCcurrent Partno. DILER-22-G(220VDC) Articleno. 010091 CatalogNo. XTRM10A22BD Product range DILER Mini-contactors Application Contactor relays Description with

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE 8 POWER SUPPLIES Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p8-10 Perth (08) 9248 0410 Sydney (02) 9676 1671 Melbourne (03) 9706 4599

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Thermal Overload Relays

Thermal Overload Relays Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays New generation of Contactors from LS Industrial Systems Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol

More information

Quick selection table

Quick selection table Quick selection table Contactors... 100 to 800A Frame size 100A 15A 150A -pole Contactors s AC/DC common coil See page 46 for more details CGC-100 CGC-15 CGC-150 See page 46 for more details Ratings /

More information