1 Products and solutions for photovoltaic applications
2 Components for string and interface control panels Switch disconnectors Surge protection devices Fuse holders The range of LOVATO Electric components for photovoltaic installations provides the solution to issues related to the control of direct currents where the use of high performance products are needed to ensure essential isolation. L1 L2 L3 N Voltage and frequency control relay Contactors DC to AC INVERTER Fuses Surge protection devices Switch disconnectors Fuse holders
3 Products and solutions for photovoltaic applications 1000VDC... 4 Excellent design features have allowed the rated operational voltage upgrade of these switch disconnectors to 1000VDC in DC21 class, a characteristic increasingly in demand for modern photovoltaic systems. Fuse holders and fuses 1000VDC... 6 Fuse holders and fuses for the photovoltaic sector, designed to protect strings with up to 32A current and 1000VDC operational voltage rating. Voltage and frequency control relay... 7 A single voltage and frequency protection for single and three phase cogeneration systems, also equipped with ROCOF (Rate Of Change Of Frequency) function. Contactors A range including three and four pole versions, up to 1600A in AC1 duty, with AC and DC coil. Measuring instruments Digital multimeters and power analyzers, expandable, with graphic LCD, in addition to digital voltmeters, ammeters, wattmeters, frequency meters, power factor meters form a complete range of measuring instruments for comprehensive control of the AC side of a photovoltaic system (inverter output, delivery point and load connection). Energy meters Single-phase types up to 63A, three-phase model with direct connection up to 63A or by current transformer and a data concentrator. Among the best on the market also because of the compact size, function expandability and a selection of monitored measurements. MID certified versions, per EU Directive 2004/22/EC, also avalable. Current transformers Ranging from 40A to 400A primiary current and 5A secondary; solid and split core versions available. Switching power supplies Suitable for single, two and three phase systems. 12V and 24V output, modular and DIN rail mount versions available. 3
4 Products and solutions for photovoltaic applications GA series GAX42...D GAX60... Configuration 4 GAX42 040D GAX42 040D GAX60 00 GA080 D - GA080 D GAX42 080D / GAX42 125D GAX42 040D GAX60 00 GAX42 080D / GAX42 125D GAX60 01 GAX60 01 GAX42 080D / GAX42 125D Order Conventional Rated operational Qty Wt code free air current Ie per thermal current Ith DC21B (800V) Poles in series 4 p 6 p 8 p [A] [A] [A] [A] n [kg] Direct operating version, complete with black handle GA080 D Fourth pole, simultaneous closing operation as switch poles. GAX42 040D GAX42 080D GAX42 125D Mechanical coupling system for 6-8 pole switch disconnectors. GAX60 00 For mm. GAX60 01 For GA080 D and mm. UTILISATION IN DC21B CATEGORY Operational Maximum operational current voltage Ue in a configuration with: [V] [A] [A] [A] 2 POLES IN SERIES. Products to GA080 D fit together POLES IN SERIES. Products to GA080 D fit together POLES IN SERIES. Products to + GA080 D + + fit together GAX42 040D GAX42 080D GAX42 125D POLES IN SERIES. Products to + GA080 D + + fit together + GA080 D + + GAX60 00 GAX60 01 GAX POLES IN SERIES. Products to + GA080 D + + fit together + GA080 D + + GAX42040D+ GAX42080D+ GAX42125D+ GAX42040D+ GAX42080D+ GAX42125D+ GAX60 00 GAX60 01 GAX General characteristics 40A to 125A ratings Available versions: direct operating door coupling version. Use switch disconnector with direct actuator and separately order the handle and shaft extension for this version. Screw or 35mm DIN (IEC/EN 60715) rail fixing Padlockable in 0 position with no extra accessory Available accessories : auxiliary contacts with simultaneous closing as switch disconnector poles auxiliary contacts with early-make closing respect to switch disconnector poles eartch and neutral terminals single and three-pole terminal covers shaft extensions for door-coupling handles up to 500mm long door-coupling handles with screw and ring fixing. Rated insulation voltage Ui: 1000V Rated impulse withstand Uimp: 8kV Mechanical life: 100,000 cycles for 30,000 cycles for GA080 D and. Certifications and compliance Certifications obtained: culus (to UL508/CSA C22.2 n 14 for, GAX42 040D and GAX60 00; to UL98/CSA C22.2 n 4 for GA080 D,, GAX42 080D, GAX42 125D and GAX60 01); GOST. Compliant with standards: IEC/EN , IEC/EN , UL508, UL98, CSA C22.2. DIMENSIONS [mm] Mechanical coupling system GAX GAX Mechanical coupling system GAX60 01 GAX GA080 D - GA0125 D Fourth pole GAX42 040D Fourth pole GAX42 080D - GAX42 125D
5 Products and solutions for photovoltaic applications GE series GE...DT4 GE... DT4P Direct operating handle GEX6 5D-GEX6 8D Order Conventional Rated Qty Wt code free air operational per thermal current Ie current DC21B❶ Ith (220V) (800V) [A] [A] [A] n [kg] Version for photovoltaic applications. Separately order the handle and shaft extension. GE0160 DT4P❷ GE0160 DT GE0250 DT GE0315 DT GE0630 DT GE0800 DT GE1250 DT ❶ Connection of four poles in series. ❷ Standard supplied with IP20 terminal protection. Order Characteristics Qty Wt code per n [kg] DIRECT OPERATING HANDLE, PADLOCKABLE. Rotating type with screw fixing on switch disconnector. Complete with shaft insert. GEX6 5D 50mm black lever GEX6 6D 105mm black lever GEX6 7D 245mm black lever GEX6 8D 285mm black two-hand lever General characteristics 160A to 1250A ratings Available versions: direct operating door coupling. Use switch disconnector with direct operation and separately order the handle and shaft extension. Screw fixing; 35mm DIN rail mount adapter kit for GE0160 DT4P Padlockable at 0 position with no extra accessory Available accessories: auxiliary contacts terminal covers 35mm DIN rail adapter kit for GE0160 DT4P shaft extensions for door-coupling handles up to 600mm long door-coupling handle with screw fixing. Rated insulation voltage Ui: 1000V Rated impulse withstand Uimp: 8kV for GE0160 DT4, GE0160 DT4P, GE0250 DT4, GE0315 DT4 12kV for GE0630 DT4, GE0800 DT4, GE1250 DT4 Mechanical life: 30,000 cycles for GE0160 DT4, GE0160 DT4P 20,000 cycles for GE0250 DT4, GE0315 DT4 10,000 cycles for GE0630 DT4, GE0800 DT4, GE1250 DT4. Certifications and compliance Certifications obtained: GOST. Compliant with standards: IEC/EN , IEC/EN Configuration DC21B CATEGORY UTILISATION Product to Operational voltage Ue order and 48V 110V 220V 400V 440V 500V wire Maximum operational current [A] [A] [A] [A] [A] [A] 4 POLES IN SERIES. GE0160 DT4P GE0160 DT GE0250 DT GE0315 DT GE0630 DT GE0800 DT GE1250 DT Product to Operational voltage Ue order and 600V 750V 800V 850V 900V 1000V wire Maximum operational current [A] [A] [A] [A] [A] [A] 4 POLES IN SERIES. GE0160 DT4P GE0160 DT GE0250 DT GE0315 DT GE0630 DT GE0800 DT GE1250 DT
6 Fuse holders Products and solutions for photovoltaic applications Fuse holders FB01 D... FB01 D 1PL Order Pole Status DIN Qty Wt code configu- light size per ration n n [kg] Fuse holders for 10x38 fuse. 32A rated current In at 1000VDC. FB01 D 1P 1P FB01 D 1PL 1P YES FB01 D 2P 2P FB01 D 2PL 2P YES Rated voltage Ue: 1000VDC Rated current Ie: 32A Utilisation category: DC20B 1000VDC Suitable for fuse class: gpv Degree of protection: IP20. Reference standards Compliant with standards: IEC/EN , IEC/EN , IEC/EN , IEC/EN Fuses FE01 D... Order Rated current Qty Wt code In per [A] n [kg] Fuse,10x38 size. 30kA rated breaking capacity at 1000VDC. FE01 D FE01 D FE01 D FE01 D FE01 D FE01 D FE01 D FE01 D Rated voltage Ue: 1000VDC Rated current Ie: 2-20A Utilisation category: DC20B 1000VDC Fuse class: gpv. Conformità Conformi alle norme: IEC/EN A 4A 6A 8A 10A 12A 16A 20A PREARCING TIME (sec) PROSPECTIVE CURRENT (A) Accessories FBX 00 Order Description Qty Wt code per [A] n [kg] FBX 00 Coupling clip for x38 fuse holders FBX 01 Coupling pin for x38 fuse holders FBX 00 FB01 D... FBX 01 FBX 01 FB01 D... 6
7 Voltage and frequency control relay Products and solutions for photovoltaic applications Voltage and frequency monitoring PMVF10 Order code Rated voltage to be Qty Wt controlled Ue per [V] n [kg] Three-phase low-voltage system, with or without neutral. Compatible for single-phase low-voltage system. Minimum and maximum AC voltage and frequency plus ROCOF. PMVF10 230/400VAC Hz Status indication table Anomaly Green LED Red LED Red LED Red LED Relay output ON Vmin Vmax Hz 1 and 2 None Constantly Switched Switched Switched Energised lighted off off off Min/max Flashing Switched Switched Constantly De-energised frequency off off lighted or ROCOF Voltage Flashing Constantly Switched Switched De-energised <Vmin lighted off off Voltage Flashing Switched Constantly Switched De-energised >Vmax off lighted off General characteristics The monitoring relay PMVF10 is designed and developed to satisfy requirements of the local power authority (ENEL guide edition 2.1 of 12/2010). The authority imposes that the following automatic controls be done whenever an independent power source (e.g. wind turbine or photovoltaic systems, diesel generating set, etc.) is connected in parallel with the electrical grid (local low-voltage utility): Limits of minimum and maximum voltage values Limits of minimum and maximum frequency values Limit of the Rate Of Change Of Frequency (ROCOF). When at least one of these limits are not respected, abnormal conditions need to be signalled using a contact. Typically, the contact is used to isolate the independent power source from the electrical grid. The following protections are available: Maximum voltage Minimum voltage Maximum frequency Minimum frequency ROCOF. TRMS (True-rms) measurements of this relay allow to obtain a correct operation even in presence of harmonic voltages. The device has fixed tripping thresholds for minimum and maximum voltage while those for frequency can be selected between two predefined values using a rotary switch. A reset delay is adjustable by potentiometer. Self powered by the system to control Compatible for: Three-phase systems (400VAC 50Hz), with or without neutral Single-phase systems (230VAC 50Hz) TRMS measurements 2 relay outputs, each with one changeover contact, rated 8A 250VAC in AC1 Modular DIN housing (3 module) Degree of protection: IP40 on front (only when mounted in housing or electric board with IP40); IP20 on terminals. PROTECTIONS For maximum voltage: Threshold 1.13Ue (fixed) Tripping time 0.1s (fixed). For minimum voltage: Threshold 0.825Ue (fixed) Tripping time 0.2s (fixed). ADJUSTMENTS Mode Reset delay Multifunction rotary switch: Control of phase or phase-to-phase voltage values Frequency threshold ±0.3 or ±1Hz ROCOF (>0.5Hz/s) ON-OFF. Resetting time s. STATUS INDICATIONS 1 green LED for system within limits (flashing when out of limits) 3 red LEDs for minimum and maximum voltage, minimum and maximum frequency and ROCOF. Certifications and compliance Certifications obtained: local power authority (ENEL Guide, edition /2010). Compliant with standards: IEC/EN , IEC/EN , IEC/EN
8 The products described in this publication are subject to be revised or improved at any moment. Catalogue descriptions and details, such as technical and operational data, drawings, diagrams and instructions, etc., do not have any contractual value. In addition, products should be installed and used by qualified personnel and in compliance with the regulations in force for electrical systems in order to avoid damages and safety hazards. LOVATO ELECTRIC S.P.A. CONTROL SOLUTIONS FOR INDUSTRY Present in over 100 countries VIA DON E. MAZZA, GORLE (BERGAMO) ITALY Tel Fax Sales department: Tel Fax LOVATO Electric offices in the world United Kingdom LOVATO ELECTRIC LTD Tel Czech Republic LOVATO SPOL. S.R.O. Tel Germany DELTEC LOVATO GmbH Tel USA LOVATO ELECTRIC INC Tel Spain LOVATO ELECTRIC S.L.U. Tel Canada LOVATO ELECTRIC CORPORATION Tel PD75 GB Poland LOVATO ELECTRIC SP. Z O.O. Tel Mexico LOVATO ELECTRIC DE MEXICO, S.A. DE C.V. Tel
FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES
FUSIBLE DISCNECT SWITCHES (UL98) GM SERIES Three-pole disconnect switches with fuse holder (UL98) GMF...030 C12 GMFJ 100 C03 GMFJ 400 C03 GMFJ 800 C03 Add-on blocks GMX10 10 GMX3... GMX8 00 GMX8 01 GMX5...
More informationAutomatic battery chargers
Automatic battery chargers electric Switching battery chargers BCF... rder code Rated Rated Qty Wt output output per current voltage pkg DC [A] [V] n [kg] 1 charging level. BCF 0250 12 2.5 1 0.270 12 BCF
More informationSWITCH DISCONNECTORS PLANET -SWITCH.
SWITCH DISCONNECTORS 6A to 600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 50A. PLANET -SWITCH SEC. PAGE
More informationPage 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.
Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated
More informationFuse holders and fuses
Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator
More informationGENERAL PURPOSE RELAYS
GENERAL PURPOSE RELAYS HR SERIES HR series General purpose relays General purpose relays are designed to control various types of loads inside machines, simple or very complex systems and plants. They
More informationSwitches Unlimited Phone: * Fax:
For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings
More informationAdd-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...
Three-pole versions up to 630A in IEC AC3 duty Four-pole versions up to 1600A in IEC AC1 duty Versions for power factor correction up to 100kvar at 400VAC Four-pole versions with NO+NC or 4NC main poles
More informationPage 2-4 Page 2-8. Page Page 2-13
Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More informationSIRCO M and MV Universal load break switches from 16 to 160 A
SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV
More informationFor Info: Phone: Fax:
Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC
More informationDefinite purpose contactors
Definite purpose contactors Three-pole and four-pole non-reversing DP contactors 600VAC T4 DPBF09 - DPBF12 - DPBF18 - DPBF09 T4 - DPBF12 T4 - DPBF18 T4 DPBF26A DPBF32A DPBF50 DPBF80 Motor Locked Rotor
More informationLoad break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...
Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationThermal Overload Relays
Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They
More informationPage 2-4 Page 2-8. Page Page 2-12
Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V
More informationSD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,
4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationCOMPLETE SOLUTIONS FOR POWER PROTECTION
COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX
More informationContact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE
Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe
More informationK50H004UP cam changeover switch - 4-pole A - screw mounting
Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationCylindrical fuse-link
Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection
More informationSquare D General Purpose Relays
Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................
More informationPOWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE
8 POWER SUPPLIES Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p8-10 Perth (08) 9248 0410 Sydney (02) 9676 1671 Melbourne (03) 9706 4599
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationFUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS
1 2 06 PML 10/14x85 1500V FUSE HOLDERS 08 CLIP CONTACT FOR φ10 FUSE LINKS 05 PMX & 14x51 FUSE HOLDERS 02 gpv & 14x51 600 &/1100 FUSE LINKS 03 gpv 1200 & 1500V FUSE LINKS 04 gpv NH1, NH2 & NH3 FUSE LINKS
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More informationThermal overload relay TF65 and TF96
Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and
More informationDRX 125 Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.
More informationMS General Information Extended Product Type: MS
MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual
More informationElectronic overload relays EF205 and EF370
Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationPowerLine OS Switch Fuses A, 690V
Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected
More informationPANEL PANEL MOUNTING COMPONENTS
PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology
More informationThermal overload relay TF140DU and TF140DU-V1000
Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against
More informationModular contactors and relays
pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation
More informationC 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers
SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection
More informationInstallation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue
FAQs I have installed the ATS panel but it won t go into the mains supply? First check all cables are in place and properly installed and that the control fuses (A-C on page 4) have not blown. If it still
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationfuse-links & fuse holders PHOTOVOLTAIC
fuse-links & fuse holders 04 gpv FOR APPLICATIONS 04 gpv FOR APPLICATIONS 05 gpv & FOR APPLICATIONS 06 PMF FUSE HOLDERS FOR APPLICATIONS 07 ST & FUSE BASES FOR APPLICATIONS FUSE HOLDERS & BASES gpv 10x38
More informationK30H001YP cam star-delta switch - 3-pole A - screw mounting
Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationMOTOR CONTROL AND PROTECTION
MOTOR CONTROL AND PROTECTION Head office Via Don E. Mazza, 12 24020 Gorle, Bergamo, Italy Tel. +39 035 4282111 Fax +39 035 4282200 info@lovatoelectric.com CONTROL AND SIGNALLING Sales department Tel. +39
More informationLV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity
LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationDRX 250 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationLow Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011
Low Voltage Interpact Switch-disconnectors INS/INV40 to 2500 A Catalogue 2011 Interpact INS/INV Contents Presentation 2 Functions and characteristics A-1 Installation recommendations B-1 Dimensions and
More informationCTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.
More informationXCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx
Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ
More informationRSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A
Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial
More informationNon-fusable disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages
More informationCI-TI Contactors and Motor Starters Type CI 6-50
Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components
More informationOverview of Low voltage equipment - Moulded-case & Air circuit-breakers
Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are
More informationCOMPONENTS. Off-load Switch for Fixed Installation Title type SW
COMPONENTS Off-load Switch for Fixed Installation Title type SW General information The SW off-load switch is a complete range designed to cover all the applications to be met in DC traction power substations
More informationKtec Contactors and thermal overloads
Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America
More informationand other modular devices for low voltage installation
Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories
More informationApprovals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking
MainswitchSurfacemounting Partno. P1-25/I2/SVB-SW Articleno. 207294 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationINDUSTRIAL CYLINDRICAL FUSE LINKS
gg Cylindrical gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high withstand to internal
More informationDRX 100 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL
More informationApprovals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking
MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A
ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat
More informationSIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A
Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented
More informationUltraSafe US22 Modular fuse-holders
UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards
More informationMS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories
Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10
More information25A 25A 32A 40A 40A 63A 63A 80A
ISDC Compact Range 25A - 200A Control Panel Isolation Equipment Craig & Derricott has ranges of Switch-Disconnectors, Fuse Combination Units and Changeover Isolators for panel mounting ranging from 25A
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More information1 Phase electronic contactor (SC 1)
1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationFUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems
FUSERBLOC CD The universal Fuse Combination Switch FROM 20 TO 1250 A SOCOMEC GROUP SWITCHING PROTECTION & UPS Industrial Switching & Protection Systems SWITCHING FUSERBLOC CD THE UNIVERSAL FUSE COMBINATION
More informationContactors. C110B/80, C110B/120 C110B/200, C110B/300 Single pole DC NO contactors for industrial trucks Catalogue B71.en
Contactors C110B/80, C110B/120 C110B/200, C110B/00 Single pole DC NO contactors for industrial trucks Catalogue B71.en 42 C110B Series DC NO contactors for battery voltages C110B Series contactors are
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationS840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en
Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break
More informationProduct brochure. ABB Fusegear EasyLine Fuse switch disconnector
Product brochure ABB Fusegear EasyLine Fuse switch disconnector 2 EasyLine Fuse Switch Disconnector ABB Fusegear Content Fuse protection 4 Technical Data 5 General 6 Apparatus overview 7 Electronic Fuse
More informationSIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationSolar Installer Range. Bright solutions
Solar Installer Range Bright solutions IMO is at the forefront of control component technology specifically developed for the renewable energy market and in particular solar energy. Whether meeting the
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationRX 3 MCB 4500 A Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1
MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationAC Switches: ML & MN Series DC Switches: MDC1A Series
AC Switches: ML & MN Series DC Switches: MDC1A Series Australian & New Zealand Distributor Leveltec Engineering Pty Ltd Gloucester P:+612 6558 9264 F:+612 6558 1002 Sydney P:+612 9299 5630 F:+612 6558
More informationMulti 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com
Multi 9 TM Catalogue 207 Multistandard protection for OEM schneider-electric.com Green Premium TM Endorsing industry eco-friendly products Schneider Electric s Green Premium ecolabel is committed to offering
More informationNB1 Miniature Circuit Breaker
P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide
More informationNF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)
More informationAF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440
More informationThe breakers offer thermal-magnetic trip protection according to Z and K characteristics.
Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific
More informationAF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationInstructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.
Deliveryprogram Contactorrelay,2N/O+2N/C,DCcurrent Partno. DILER-22-G(220VDC) Articleno. 010091 CatalogNo. XTRM10A22BD Product range DILER Mini-contactors Application Contactor relays Description with
More informationSoftstarters Softstarters
, PSS & PST(B), PSS & PST(B) Low Voltage Products & Systems 6.1 General information PSR PSS From the moment the first electrical motors appeared, engineers have been searching for a way to avoid electrical
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More informationSafety rope switches with reset for emergency stop
Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationEmergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0
MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More information