1 Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower performance with a design that is up to 40% smaller than traditional contactors of this rating. The entire line is modularly designed for easy inspection, contact replacement and coil change out. ll maintenance can be performed from the front so that mounting can be accomplished with no wasted space on the sides. The contactor for large horsepower applications The C5 series consists of four contactors in two frame sizes covering motors from 500 to 900 HP (at 460V/575V). This line is well suited for heavy industrial applications utilizing large machinery and equipment such as rock quarries and mines, or for any large horsepower application where a rugged and dependable contactor is needed. Specially designed shockfree contact system characteristic of contactors in this size class is to transmit intense impact forces during operation. This is caused by the heavy magnetic armatures of the core, which can cause contact bounce. C5 contactors, however, are designed so that the operating planes of the electromagnets and the contacts are opposed to each other by Direction of electromagnets (coil armature) Direction of main contacts 90. This results in a bounce-free contact system, increasing the contactor s mechanical life and raising contact reliability. Rugged and reliable massive steel framework supporting the magnet system ensures high stability in all applications. Low-wear materials for bearings and sliding surfaces, as well as generously dimensioned magnet-pole faces result in above average mechanical life with a minimum of maintenance. Despite their rugged construction, overall contactor weight has been reduced considerably permitting simpler panel construction and easier assembly. 280mm ( 11 ) mm ( 13 3/16 )

2 Unique coil feeder group offers many advantages C5-700 and 860 contactors are equipped with a special feeder group for the coil that accommodates C control voltages of 50 or 60Hz, and a wide range of DC voltages. djustable auxiliary contacts C5 contactors can be equipped with a maximum of four NO and four NC auxiliary contacts. In addition, the closing time of the auxiliary contacts (on C5-700 & 860 contactors) can be adjusted to meet individual control requirements. Two choices for interlocking reversing contactors Unique to the C5 range is the ability to mechanically interlock reversing contactors in either a horizontal or vertical orientation. This feature allows maximum flexibility when laying out panels. This coil arrangement eliminates noise and provides very low pickup and hold-in current. In addition, the dropout time of the coil can be adjusted within one of three ranges. Normal Drop (150 to 200ms): for prompt reaction of contactor to a breaking command (factory setting). Delayed Drop (0.5 to 1s): where it is necessary for the contactor to be immune to short power supply interruptions or uncertain control devices. Fast Drop (about 20ms): for safety applications where instant dropout is required. Modular, convenient design The C5 line is modularly designed for easy inspection, coil change and contact replacement. Maintenance can be performed from the front so that mounting requires no additional space. Even with the installation of mechanical interlocks and auxiliary contact blocks, the units can be flush mounted side by side, saving panel space. dd-on fourth pole In many applications, the neutral also needs to be switched. ll C5 contactors can be fitted with a 4th pole on either the left or right side of the contactor. This switched neutral is available as an accessory that can easily be installed in the field. DISCONTINUED 4 5 Horizontal mechanical interlock Vertical mechanical interlock Simple main contact inspection and easy coil change C5-700 Contactor 2 C Contactor 3 Coil Pair 4 Feeder Group 5 4th Pole (Neutral Switching) 6 uxiliary Contact Block 7 uxiliary Contact Block 8 Mechanical Interlock (horizontal) 9 Mechanical Interlock (vertical) full range of C5 accessories is available, including a unique mechanical interlock that allows vertical mounting of contactors (see explanation above)

3 DISCONTINUED Non-Reversing, Three Pole Contactors With C or DC Coil, Series C5 (Open type only) ➊➌ Ratings for Switching C Motors (C2 / C3 / C4) uxiliary I e [] kw (50 Hz) UL/CS HP (60 Hz) ➌ 3 Ø Contacts per Contactor 400V C-3 C-1 230V 415V 500V 690V 200V 230V 460V 575V NO NC Open Type Catalog Number ➊➌ C Contactors - C and DC Coil Price Three Pole Series C C ~ ~ ~ ~ 1 2 C C contactor C Note: C5 open-type contactors include terminal bolts. See page 160 for Lugs. C contactor Coil Codes ➊➋ C5-700 / 860 C & DC Voltage Range Coil Code 50 Hz 60 Hz VDC V V VDC V V VDC V V VDC V V VDC Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code C Coil Code See Coil Codes on this page C / 1200 Voltage Range 50 Hz 60 Hz V 110V V 220V V 380V V 440V V V ➊ C5-700 and 860 contactors are equipped with coils that operate with both C and DC control voltages. C and 1200 contactors operate with C control voltage input that is rectified for DC coil operation. See page 161. Consult factory for DC control voltage input. ➋ Other voltages available, see page 161. ➌ C horsepower ratings per IEC Utilization category C-3. See C5 Technical Data section for additional sizing information. Label does not bear a UL/CS horsepower rating. 158

4 uxiliary Contact Blocks (2 & 4 Pole) Contact Block Description NO NC 4-pole For mounting between T1 & T2 or between T2 & T3 djustable; provides normal, delayed or overlapping contacts ➊ Maximum two blocks per contactor ➋ lternate terminal marking tags included DISCONTINUED 2 2 ccessories Field Installable Contact rrangement For use with... Catalog Number Price Standard terminal marking for mounting between T1 & T lternate terminal marking for mounting between T2 & T3 C5-700 C5-860 C5-EF22 ➋ pole For side mounting on either side of the contactor Maximum four blocks per contactor ➌ lternate terminal marking tags included 1 1 Standard terminal marking C C C5-EB11 ➌ 725 l One supplied standard with contactor l Special two pole design; 1 NO delayed make, 1 NC l NO delayed make contact used for operation of the Feeder Group/Coil mechanism 1 Delayed Make C C C5-EB11DC pole Switched Neutral (4th Pole) ➍ 4th Pole 4th Pole mperes I th C For use with... Catalog Number Price C5-700 C5-860 C5-NP500/ C5-700 C5-860 C C C5-NP1000/ C5-NP1000/ ➊ Further information on adjustable contacts can be found under uxiliary Contacts in the C5 Technical Section. ➋ Contactor comes standard with one 4-pole aux contact block. ➌ In addition to one standard two-pole auxiliary contact block (C5-EB11), C & 1200 contactors are equipped from the factory with a special two pole auxiliary contact block (C5-EB11DC). One of the poles is used for operation of the Feeder Group/Coil mechanism, the other NC contact is available for use. Two additional aux contact blocks may be added for a total of four. ➍ No UL or cul approval. 159

5 ccessories - Field Installable Main Lugs Lug or ccessory Description Wire Size Catalog Number Price Screw Type Lugs - (set of 6) For C5-700 For C5-860 For C & C ➊ (2) 3/0-750MCM (3) 2-600MCM (4) 1/0-750MCM C5-700-LU C5-860-LU C LU Mechanical Interlock Kit Mechanical Latch For Horizontal Mounting of Contactors Interlock For use with... Catalog Number Price Latch For use with... Catalog Number Price C5-700 C5-860 C5-700/C5-860 C5-700/C C5-700/C C5-860/C C5-860/C C5-BM6H 757 C5-BM67H 2310 C5-700 C5-860 C5-M C C C5-1000/C C5-BM7H 1430 For Vertical Mounting of Contactors C5-700 C5-860 C5-700/C5-860 C5-700/C C5-700/C C5-860/C C5-860/C C5-BM6V 757 C5-BM67V 2310 C Coil Code C5-M6- Replace with Coil Code Voltage Range 50 Hz / 60 Hz V - 120V V - 240V V - 415V V - 480V C C C5-1000/C C5-BM7V ➊ C is not UL Listed. 160

6 ll C5 contactor coils are made up of two parts; the Coil Pair and Feeder Group. When ordering replacement parts, usually assume the Coil Pair must be replaced. If control voltage changes, user must order Coil Pair and matching Feeder Group. Even though all C5 coils are designed for C input (DC input also available for C contactors), they are operated by a DC voltage supplied from a feeder group. lways order Renewal Parts by the Coil Code matched to the actual control voltage available to the contactor. Further information on C5 coil pairs and feeder groups can be found in C5. C & DC Coil Pairs & Feeder Groups (C5-550 to C5-860) ➊➋ C5-550 C5-700 & C5-860 Voltage Range COIL CODES Coil Pair Feeder Group Coil Pair Feeder Group V 50/60Hz TX734 TXS734 TY734 TYS VDC ( ) ( ) ( ) ( ) V 50/60Hz TX747 TXS747 TY747 TYS VDC ( ) ( ) ( ) ( ) V 50/60Hz TX779 TXS779 TY779 TYS VDC ( ) ( ) ( ) ( ) V 50/60Hz TX780 TXS780 TY780 TYS VDC ( ) ( ) ( ) ( ) Price C Coil Pairs & Feeder Groups (C & C5-1200) ➊➋ Voltage Range Volts 50/60Hz Volts 50/60Hz Volts 50/60Hz 440 Volts 50/60Hz Volts 50/60Hz C COIL CODES C & C Coil Pair TZ734 ( ) TZ747 ( ) TZ779 ( ) TZ780 ( ) Feeder Group TZS734 ( ) TZS747 ( ) TZS779 ( ) TZS780 ( ) 480 TZ781 TZS781 Price DC Coil Pairs & Feeder Groups (C & C5-1200) ➋➌ Voltage Range 110 Volts DC 220 Volts DC 440 Volts DC DC COIL CODES C & C Coil Pair Feeder Group 110D Refer to factory Refer to factory 220D Refer to factory Refer to factory 480D Refer to factory Refer to factory Price Refer to factory Refer to factory C5 Feeder Group - front view (typical) ➊ Other voltages available. Please contact factory. ➋ C5-550, 700 and 860 contactors are equipped with coils that operate with both C and DC control voltages. For DC coil operation, select C Coil Code for desired DC voltage. C and 1200 contactors operate with C control voltage input that is rectified for DC coil operation. See page 167. Consult factory for DC control voltage input. C5 Coil Pair (typical) C5 Feeder Group - rear view (typical) Discount Schedule B6 161

7 Renewal Parts Main Contact - (1 Pole Per Set) Main Contacts (1pole) (typical) For use with... C5-550 C5-700 C5-860 C C Catalog Number C5-CP550 ( ) C5-CP700 ( ) C5-CP860 ( ) C5-CP1000 ( ) C5-CP1200 ( ) Price per pole rc Chutes rc Chutes (typical) 3-pole (1 per contactor) For use with... Catalog Number Price C5-550 C5-700/ C5-860 C5-C550 ( ) C5-C860 ( ) C5-1000/ C C5-C1200 ( ) pole (3 per contactor) 162 Discount Schedule B6

8 C5-550 C5-700 ➊ C5-860 C C Rated Insulation Voltage U i to IEC947-1 [V] UL/CS [V] Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] C / 1200 [kv] Rated Voltage Ue-Main Contacts C 50/60Hz [V] 220/230, 240, 380/400,415,500,660/690 (1000V - C5-550 to 860) DC [V] 24, 48, 110, 220, 440V Operating Frequency for C Loads [Hz] 50/60Hz 180/hr. for 0.25s start time - 42/hr. for 1s start time Switching Motor Loads Standard IEC Ratings C-2, C-3 230/240V [] DOL & Reversing 400/415V [] Hz/60 C 500V [] V [] V [kw] V [kw] V [kw] V [kw] V [kw] V [kw] UL/CS 200V [] ~ 1185 DOL & Reversing 230V [] ~ Hz 460 V [] ~ V [] ~ V [HP] ~ V [HP] ~ V [HP] ~ V [HP] ~ 900 C4-200,000 Op. Cycles 230/240V [] Hz 400/415V [] V [kw] V [kw] V [kw] V [kw] C4-200,000 Op. Cycles (25,000) 230/240V [] (630) (700) Squirrel-cage motors with reversing 400/415V ➊ [] (630) (700) and jogging 230V [kw] (205) (228) 240V [kw] (214) (245) 400V [kw] (357) (414) 415V [kw] (359) (424) ➊ t rated voltage (415V) and rated current: Life span 25%. 163

9 Electrical Data C5-550 C5-700 C5-860 C C Switching Motor Loads (continued) Wye-Delta (Star Delta) 230V [] Hz 240V [] V [] V [] V [] V [] V [kw] V [kw] V [kw] V [kw] V [kw] V [kw] Hz 230V [HP] V [HP] V [HP] C-1 Load, 3 Switching I th [] mbient Temperature 40 C 230V [kw] V [kw] V [kw] V [kw] V [kw] V [kw] mbient Temperature 60 C I th [] V [kw] V [kw] V [kw] V [kw] V [kw] V [kw] Continuous Current (UL/CS) General Purpose Rating (40 C) [] ~ 1215 Rated Making Capacity 415V [] C-3 I e 500V [] V [] Rated Breaking Capacity 240V [] C-3 I e 400V [] V [] V [] V [] Short Circuit Protection of Contactors Without Overload Relay Fuse gg (am) Type 1 Coordination 500V [] (630) (per IEC ) 690V [] (630)

10 Electrical Data C5-550 C5-700 C5-860 C C DC Ratings DC-1 Rating at 60 C Non-inductive or slightly 1 pole 24VDC [] inductive loads, resistive furnaces 48VDC [] VDC [] VDC [] Poles in Series 110VDC [] VDC [] VDC [] VDC [] Poles in Series 110VDC [] VDC [] DC-3 Rating at 60 C Shunt wound motors - 3 Poles in Series 24VDC [] Starting, reverse current 48VDC [] breaking, reversing, stepping DC-5 Rating at 60 C Series wound motors - 3 Poles in Series 24VDC [] Starting, reverse current 48VDC [] breaking, reversing, stepping Lighting Loads Elec.Dischrg.Lamps-C-5a, Open [] single compensated Enclosed [] Incandescent Lamps - C C-5b, Electrical endurance ~100,000 operations [] Switching power transformers C-6a Inrush = nxi e Rated transformer current Inrush 400 VC [] 7,440 9,450 11,700 13,500 16, VC [] n= VC [kv] VC [kv] VC [kv] n= VC [] n= VC [] Rated making Capacity C-3 I e 415V [] 5,500 7,000 8,600 10,000 12, V [] 5,500 7,000 8,600 10,000 12, V [] 5,500 7,000 8,600 10,000 12,000 Rated making Capacity C-3 I e 240V [] 4,400 5,600 6,900 8,000 9, V [] 4,400 5,600 6,900 8,000 9, V [] 4,400 5,600 6,900 8,000 9, V [] 4,400 5,600 6,900 8,000 9, V [] 4,000 5,100 5,600 6,900 8,

11 Electrical Data C5-550 C5-700 C5-860 C C Capacitor Ratings Capacitor Switching - 50Hz Single Capacitor - 40 C 230 V [kvar] V [kvar] V [kvar] V [kvar] V [kvar] V [kvar] Single Capacitor - 55 C 230 V [kvar] V [kvar] V [kvar] V [kvar] V [kvar] V [kvar] Capacitor Bank - 40 C 230 V [kvar] V [kvar] V [kvar] V [kvar] V [kvar] V [kvar] Capacitor Bank - 55 C 230 V [kvar] V [kvar] V [kvar] V [kvar] V [kvar] V [kvar] Short-Circuit Coordination Short Time Current Withstand Ratings I cw 60 C 1 s [] s [] s [] s [] s [] s [] s [] Off Time Between Operations [Min.] Resistance and Watt Loss l e C3 Resistance per power pole [mw] Watt Loss - 3 power poles [W] Coil and 3 power poles C [W] (including series resistor) DC [W]

12 Electrical Data DISCONTINUED C5-550 C5-700 C5-860 C C Coil Data Voltage Range C: 50Hz, 60Hz, 50/60 Hz Pickup [xu s] Dropout [xu s] DC Pickup [xu s] Dropout [xu s] Coil Consumption C: 50Hz, 60Hz, 50/60 Hz Pickup [V] Hold-in [V] DC Pickup [V] Hold-in [W] Operating Times C: 50Hz, 60Hz, 50/60 Hz Pickup [ms] Normal Dropout [ms] Delayed Dropout [ms] ~ ccelerated Dropout [ms] ~ DC Pickup [ms] Normal Dropout [ms] Delayed Dropout [ms] ~ ccelerated Dropout [ms] ~ Insulation Class Class B to VDE 0660 table 22 Control and Magnet System for C5-700 C5-860 Contactors Even though the input to the magnet system can either be C or DC, the low pull-in and holding consumption of the magnet system is achieved by DC operating coils supplied by a Feeder Group. The Feeder Group for these contactors also allows delayed, normal or accelerated dropout times, selectable between 20ms and 1000ms. Delayed: ( ms) Normal: ( ms) ccelerated: (20 50ms) s supplied, the contactors are wired for a normal dropout time. To compensate for wide voltage fluctuations or brief supply voltage interruptions, the dropout time can be delayed by wiring changes made to the Feeder Group at installation. C OR DC C1 ~ / + 1 RT - ~ / - 1 ~ + ~ 2 2 R VDR Normal drop Coil Circuit for C5-550, 700 & 860 C or DC supply Z M2 M1 C C Control and Magnet System for C C Contactors Even though the input to the magnet system is only designed for C voltages, the low pull-in and holding consumption of the magnet system is achieved by DC operating coils supplied by a Feeder Group. The Feeder Group for these contactors is configured for a dropout time of 25 50ms. Dropout times for these contactors are not selectable. Further information regarding circuit possibilities can be obtained from assembly instructions supplied with each device. C (ONLY) ~ RT - ~ C ~ ~ C + C C (1) RC R 22 R 11 R -12 R R C Coil Circuit for C & 1200 C supply (only) R R C: Coil pair R: DC auxiliary relay coil for economy resistor switching R, RC, RR: Economy resistor VDR: Varistor M1, M2: Terminals for fast-drop connection Z: Device for dropout operating time variation (1) For control voltages up to 125V NC contacts & are connected in parallel; higher voltages are connected in series RC 167

13 Mechanical Data C5-550 C5-700 C5-860 C C Service Life Mechanical C Control [Mil.] DC Control [Mil.] Electrical C-3 (400V) [Mil.] Shipping Weights C - C5 C Control [kg] DC Control [Lbs] C - CU5 C Control [kg] DC Control [Lbs] Terminations - Power Type Direct Connection (customer supplied connections) Hexagonal Bolt b max. [mm] c max. [mm] s max. [mm] 2 x 5 2 x 5 2 x 6 2 x 6 2 x 8 Ø min. [mm] Refer to C5 stab dimensions below Recommended Torque [Nm] [Lb-ft] C5 Stab Dimensions 168

14 Mechanical Data (continued) C5-550 C5-700 C5-860 C C Terminations - Control Description Combination Screw Head: Cross, Slotted, Pozidrive Coils 1 or 2 [mm2] 4 Wires [WG] 25 Control Modules 1 or 2 [mm2] 4 Wires [WG] 25 Torque Requirement [Nm] [Lb-in] Degree of Protection - contactor IPOO (open) per IEC and DIN Environmental and General Specifications Rated Isolation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V 690V UL/CS [V] 600V 600V Impulse Voltage - U imp 1 minute per IEC [kv] 8kV 2.5kV mbient Temperature Storage C ( F) Operation at rated current C ( F) (40 C per UL) ltitude at installed site 2000 meters above sea level per IEC Operating Frequency for C Loads 50/60 Hz 180/Hr. for 0.25, start time 42/ HR for 1s start time Resistance to Corrosion / Humidity Damp-alternating climate: cyclic per DIN and Part 38 IEC Operating Position Dry heat: IEC 68-2, C (212 F), relative humidity,50%, 7 days Damp tropical: IEC 68-2, +40 C (104 F), relative humidity 95%, 56 days ➊ See dimensions page Standards IEC/EN 60947, ul508, csa C22.2 No. 14 pprovals culus, CE ➊ Per DIN and , part

15 uxiliary Contacts DISCONTINUED uxiliary Contact Block uxiliary Contact Blocks Switching, C & DC Loads C5-EF22 C5-EB11, C5-EB11DC C-I th at 40 C [] at 60 C [] C-15, switching electromagnetic loads at: [V] [] DC-13, switching DC electromagnets at: [V] [] Minimum Switching Capacity 10V, 5M Short-Circuit Protection - ggfuse Type 2 Coordination [] Terminals Terminal Type Maximum Wire Size per IEC x 4 2 x 4 Flexible with Wire- 1 Conductor [mm 2 ] End Fernule 2 Conductor [mm 2 ] Solid/Stranded- 1 Conductor [mm 2 ] Conductor 2 Conductor [mm 2 ] Recommended Tightening Torque [Nm] Max. Wire Size per UL/CS [WG] Recommended Tightening Torque [lb-in] Degree of Protection IP2LX per IEC 529 and DIN Mechanical Latch C5-M5 C5-M6 C5-M7 Service Life Mechanical [Mil ops.] Dropout Delay Contactor Latch [ms] Trip Coil Consumption C [V] DC [W] OFF-command (min. impulse duration) [ms] Operation Voltage Minimum 0.5 U n 0.5 U n 0.5 U n Maximum 1.1 U n 1.1 U n 1.1 U n 170

16 uxiliary Contacts For C5-700 & C5-860 contactors Up to two auxiliary contact blocks can be mounted on each contactor. One four-pole auxiliary contact block (C5- EF22) is supplied standard and is installed on the contactor between T1 and T2. One additional auxiliary contact block can be installed between T2 and T3. Normal Setting (from factory) uxiliary NC Contacts NO Setting range Main Contacts (open) Each C5-EF22 contains 2 NO and 2 NC adjustable auxiliary contacts. Standard terminal markings are shown below on the left. If an additional contact block is required, different terminal markings (right) are supplied and may be applied by the user. Delayed NO Contact uxiliary NC Contacts NO djusting screw after four turns to the right Main Contacts (open) djustable uxiliary Contacts The instant at which the NO contact closes, in relation to the main contacts, can be adjusted from the front of the C5-EF22 auxiliary contact block by means of an llen wrench. The following diagrams show the adjustments for Normal, Delayed and Overlapping auxiliary contacts. Overlapping NO and NC Contacts uxiliary Contacts Main Contacts (open) NC NO djusting screw after four turns to the left For C and C contactors Up to four nonadjustable auxiliary contact blocks can be mounted on each contactor. One C5-EB11 two pole aux contact and one C5-EB11DC two pole aux contact come standard. The C5-EB11DC has 1 NC contact (available) and 1 NO Delayed Make (unavailable) which is used for the operation of the coil feeder group. C5-EB11 1 NO/1NC C5-EB11DC 1 NO Delayed Make/1 NC 171

17 Life Load Curves Life-Load Curves C-1 C-3 Instructions on How to read Life Curves can be found on page 8 NOTE: The life-load curves shown here are based on Sprecher+Schuh tests according to the requirements defined in IEC Since contact life in any given application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. 172

18 Life Load Curves Life-Load Curves Inching and plugging of squirrel-cage induction motors during starting; Ue= VC C-4 10 C5-550 C5-700 C5-860 C C C-4 1 Contact Life (Millions of Operations) Rated operational current Ie C-4 [] NOTE: The life-load curves shown here are based on Sprecher+Schuh tests according to the requirements defined in IEC Since contact life in any given application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. 173

19 Life Load Curves Life-Load Curves C-3 (90%), C-4 (10%) 10 Mixed operation with squirrel-cage induction motors C-3-90% starting and stopping of running motors; Ue= VC C-4-10% starting with inching and plugging; Ue= VC C5-550 C5-700 C5-860 C C C-3 90% C-4 10% 1 Contact Life (Millions of Operations) Contact Life for Mixed Utilization Categories C-3 and C-4 In many applications, the utilization category cannot be defined as either purely C-3 or C-4. In those applications, the electrical life of the contactor can be estimated with the following equation: L mixed = L ac3 / [1+P ac4 x (L ac3 /L ac4-1)], where: Rated operational current Ie C-3, C-4 [] L mixed L ac3 L ac4 P ac4 pproximate contact life in operations for a mixed C-3/C-4 utilization category application. pproximate contact life in operations for a pure C-3 utilization category (from the C-3 life-load curve). pproximate contact life in operations for a pure C-4 utilization category (from the C-4 life-load curve). Percentage of C-4 operations NOTE: The life-load curves shown here are based on Sprecher+Schuh tests according to the requirements defined in IEC Since contact life in any given application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. 174

20 Operating Rate Curves C Starting and stopping of running motors Starting time t = 0.25 s Relative time energized 40% C5-550 C5-700 C5-860 C C DISCONTINUED C-3 Operating Rates 400 Permissible switching frequency (starts per hour) Rated motor current Ie C-3 [] 175

21 DISCONTINUED Series C5 & Series CU5 (Contactors & Reversing Contactors) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. e2 c1 e1 øe øf ø d Dimensions e3 d1 b1 b e3 d2 a c Type a b b1 c c1 ød d1 d2 øe øf e1 e2 e3 C (8-21/32) (10-5/32) (8-31/32) (8-7/8) (6-7/16) (3/8) (8-21/32) (4-5/8) (17/32) (1-19/32) (3-1/8) C5-700 C5-860 C C (11-1/32) 280 (11-1/32) 334 (13-5/32) 334 (13-5/32) 307 (12-3/32) 361 (14-7/32) 490 (19-9/32) 490 (19-9/32) 277 (10-29/32) 325 (12-25/32) 434 (17-1/16) 434 (17-1/16) 291 (11-15/32) 291 (11-15/32) 345 (13-9/16) 345 (13-9/16) 203 (8) 203 (8) 231 (9/32) 231 (9/32) 11 (7/16) 11 (7/16) 13 (25/64) 13 (25/64) 280 (11-1/32) 280 (11-1/32) 380 (14-31/32) 380 (14-31/32) 175 (6-7/8) 175 (6-7/8) 120 (4-23/32) 120 (4-23/32) 13 (17/32) 15 (19/32) 13 (25/64) 13 (25/64) - 11 (7/16) 13 (25/64) 13 (25/64) 50 (1-31/32) 50 (1-31/32) 60 (2-3/8) 60 (2-3/8) 101 (4) 101 (4) 100 (3-31/32) 100 (3-31/32) - 32 (1-17/64) 40 (1-9//16) 40 (1-9//16) Reversing Contactors & ccessories Contactor with... Dimension [mm] Dimension [inches] - auxiliary contact block a a - reversing contactors with mechanical interlock next to each other C /C a+42+a a+1-23/32+a C 5-700, -860/ C 5-700, -860 a+32+a a+1-1/4+a C , -1200/ C , a+46+a a+1-13/16+a C 5-550/C, 5-700, -860 a+37+a a+1-15/32+a C 5-700, -860/ C , a+73+a a+2-7/8+a above each other C /C b+56+b b+2-3/16+b C 5-700, -860/ C 5-700, -860 b b b+3-15/ /8+b C , -1200/ C , b b b+9-1/ /32+b C 5-550/C, 5-700, -860 b b b+3-15/ /8+b C 5-700, -860/ C , b b b+9-1/ /32+b four main contacts C /C 5-700, -860 a+68 a+2-11/16 C , a+76 a+3 latch C b+47 b+1-7/8 C b+64 b+2-17/32 C b+37 b+1-15/32 C , a+30 a+1-3/16 Mounting Position 176

22 Dimensions Notes 177

The contactor for large horsepower applications

The contactor for large horsepower applications Series The complete contactor for heavy industrial applications from 500HP to 900HP R Series contactors provide large horsepower performance with a design that is up to 40% smaller than traditional contactors

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads. C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,

More information

Technical Information

Technical Information Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

Technical Information

Technical Information Electrical Data C7-9 Rated Insulation Voltage U i IEC, S,BS,SEV, VDE 0660 [V] 690V UL; CS [V] 600V Rated Impulse Voltage U imp [kv] 8kV Rated Voltage U e -Main Contacts C7 3-Pole Contactors C7-2 C7-6 C7-23

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

Series CA6 Contactors

Series CA6 Contactors Series C6 Contactors classic contactor for demanding applications from 75 to 600HP (@460V) - 100 to 700HP (@ 575V) This series is being replaced by the C9 Series of contactors Sprecher + Schuh s C6 contactor

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Series C8 Miniature and Starters... 3 ccessories... 2 Contactor Cross

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose Contactors General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Contactors Series C8 Miniature Contactors and Starters... 3

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

A200 NEMA Contactors and Starters A200

A200 NEMA Contactors and Starters A200 Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Manual Motor Protectors

Manual Motor Protectors 88 Manual Motor Protectors 51 30 UP TO IMM16 Frame IMM32 Frame IMM65 Frame E468295 E468295 High interrupt capacity up to 100k (with optional current limiter) Din rail mounting Lockable handle (OFF position)

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads 22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

Controls. CONTACTORS CWB Line (up to 40A)

Controls. CONTACTORS CWB Line (up to 40A) Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

3TM Vacuum Contactors

3TM Vacuum Contactors Catalog Extract HG 11.23 Edition 2016 Catalog Extract Medium-Voltage Equipment siemens.com/3tm R-HG11-343.psd 2 Siemens HG 11.23 2016 Contents Medium-Voltage Equipment Catalog Extract HG 11.23 2016 Contents

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

Page 2-4 Page 2-8. Page Page 2-12

Page 2-4 Page 2-8. Page Page 2-12 Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Standard voltages. Alternating current (V) 50/60Hz Alternating current (V)

Standard voltages. Alternating current (V) 50/60Hz Alternating current (V) Series CK Three and four pole contactors 150 to 825 (C3) 200 to 1250 (C1) Control circuit: lternating current up to 690V Direct current up to 500V Degree of protection IP00 (IPxx with accessories) CK07...CK13:

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

Technical Information

Technical Information Technical nformation - Second Generation Solid State Overload Relays Technical nformation -ED1... -EE... -EE...D Rated nsulation Voltage - U [V] 69 C Rated nsulation Strength- U imp [kv] 6 C Rated Operation

More information

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions Installation Contactors Z-SCH These switching devices have been designed and rated particularly for modular installation in modular distribution boxes for electrical installation or cabinets with device

More information

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004 Series The WEG Series Manual provide a very compact solution for operation and protection in motor control applications. The NEC requires four functions to be considered a combination motor starter:, ranch,

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Capacitor Switching Contactors Type K3...-A, K3...-K

Capacitor Switching Contactors Type K3...-A, K3...-K Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and

More information

All round protection guaranteed

All round protection guaranteed s With SLR ll round protection guaranteed Betagard MCB 5SL Inspiring Safety nswers for infrastructure. Overview s a culture Siemens has always endeavoured to introduce innovative products worldwide. The

More information

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A TyS t M - TyS g M utomatic Transfer Switching Equipment Transfer switches new The solution for > High Rise uildings > Data centre > Healthcare buildings TyS g M I-0-II P atys-mg_001_b_1_cat Function TyS

More information

Electrical sector solutions E Line family. Industry leading design in a compact package

Electrical sector solutions E Line family. Industry leading design in a compact package Electrical sector solutions E Line family Industry leading design in a compact package The power of fusion. 87 88 89 899 90 908 9 9 9 9 97 97 977 98 98 989 999 There s a certain energy at Eaton. It s the

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

Contactors. 1.1 E Line contactors Control relays XTRG... 1 Contactors XTCG... 4

Contactors. 1.1 E Line contactors Control relays XTRG... 1 Contactors XTCG... 4 Contactors E Line contactors xstart series contactors. E Line contactors Control relays XTRG....................................................... Contactors XTCG.........................................................

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals: 3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Contactor Relays 3TH30

Contactor Relays 3TH30 Contactor Relays 3TH30 Reliability and safety are pre-requisites in the choice of the control contactor. Siemens 3TH30 contactor relays satisfy these criteria and thus offer the right choice to the customer.

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Contactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors.

Contactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors. Contactors E Line contactors. E Line contactors. xstart series contactors.3 xstart C series contactors.4 D Line contactors xstart series contactors xstart C series contactors D Line contactors X UTOMTION

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information