Contactor Types CI 61-98

Size: px
Start display at page:

Download "Contactor Types CI 61-98"

Transcription

1 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under V C-3 loads. ccessories include a wide selection of auxiliary contacts, mechanical interlocks and RC elements. uxiliary contacts for mounting on the side or top are available. The auxiliary contacts have force-actuated contacts and can form part of safety switching.

2 Ordering Contactors CI 6, CI 73, CI 86, CI 98 U e V kw Main circuit C-3 load I th2 ) U e I e (C-) V Open kw I the3 ) (C-) Encl. Main contacts (make) Number dd-on options Number Code no. ) H306 CI H3062 CI H3063 CI H3040 CI 98 ) Coil voltage/frequency or Suffix no. (see table below) must be added to the Danfoss code no. 2 ) The thermal current Ith gives the maximum load at 40 C, which corresponds to installing the contactor in air (open). 3 ) The thermal current Ithe gives the maximum load at 60 C, which corresponds to installing the contactor in an enclosure. Coil voltages and coils for CI 6, CI 73, CI 86, C98 Coil voltage) (sufix no.) 24 V 50/60 Hz 0 V, 50 Hz/60 Hz V, 50 Hz/ V, 50 Hz/60 Hz Contactor Code no. (3) (23) Hz (32) (39) CI 6 037H306 CI H3062 CI H3063 CI H vailable Special order Unavailable - CBD CBD 22 BD S- Mechanical interlock uxiliary contact block CBD for CI 6, CI 73, CI 86 and CI 98 contactors Contact function ) I e (C-5) I th2 ) (C-) Open Load I the3 ) (C-) Encl. U e V Code no. make (NO) + break (NC) H3064 CBD- 2 make (NO) + 2 break (NC) H3065 CBD-22 break (NC) H3066 CBD S-NC make (NO) H3067 CBD S-NO make (NO) + break (NC) H3069 CBD S- 2 make (NO) H3070 CBD S-20 ) Force-actuated contacts suitable for safety switching. 2 ) The thermal current Ith gives the maximum load at 40 C, which corresponds to installing the contactor in air (open). In CBD auxiliary contact the silver tips are crossstamped. In CBD S auxiliary contact the silver tips are H-shaped. 3 ) The thermal current Ithe gives the maximum load at 60 C, which corresponds to installing the contactor in an enclosure. Both contact types are PLC-compatible. Min. load 24 V, 0 m. RCD- Clip-on marker ccessories for contactors CI 6, 73, 86, 98 Description Comments Code no. Mech. interlock Mech. interlock can be established between pairs 037H3074 RCD 280 (0-280 V, 50/60 Hz) 037H3072 Clip-on markers Rating plate with cover 037H342 2

3 Description Thermal overload relays TI are used with contactors type CI 6, CI 73 and CI 86 to give overload protection of squirrel-cage motors of 30 kw to 55 kw. The relays trip under asymmetric load, i.e. accelerated release if phase drop-out occurs. Other features of TI 80 and TI 86: stop/reset button manual/automatic reset test button double scale for direct start or Y/D start signal contact with changeover Ordering Thermal overload relays TI 80 and TI 86 Motor starter Range Max. fuse ) Y/D starter gi, gl, gg type 2 BS 88, type T type 2 Code no H06 TI H07 TI H08 TI 86 ) To IEC coordination types and 2: Coordination type : ny type of damage to the motor starter is permissible. If the motor starter is in an enclosure, no external damage to the enclosure is permissible. fter a short-circuit the thermal overload relay shall be partially or wholly replaced. Coordination type 2: No damage to the motor starter is permissible, but slight contact burning and welding is permissible. Selection of thermal overload relay The selection of a thermal overload relay must be based on the motor full load current and the method of starting: -With direct start the motor starter range applies. -With star-delta start Y/D starter range applies. Example: Full load current: 85 -With direct start, the suitable motor starter range is 74-85, i.e. thermal overload relay 047H08. -With star-delta start, the suitable Y/D starter range is 75-09, i.e. thermal overload relay 047H06. Base ccessories for thermal overload relays TI Description Comments Code no. Clip-on markers For mounting on TI (250-off) 037H00566 Base For separate mounting of TI L Pushbutton extension For TI 9C-86 (3 mm) 047L Current rail set For direct mounting of TI 80/TI 86 TI for CI 98? on contactors CI (set of 3 ) 037H00866 Push button extension Current rail set 3

4 Construction standards Contactors, thermal overload relays and accessories are designed and tested in accordance with IEC 947/EN Environment Temperate climate Tested and passed in accordance with DIN and part 38 and IEC 68 Max. installation height: 2000 NN, in accordance with IEC 947 mbient temperature Operation Pulse voltage CI CI C +60 C -55 C +80 C U imp 8 kv mbient temperature Storage/Transport Environment Temperature compensated mbient temperature Vibration Shock perpendicular to contact system Max. operations per hour TI 86-5 to +40 C -50 to +60 C 2 g at 200 Hz 9 g for 7.5 ms 30 Mounting direction pprovals EN 609 UL-recognized UL-listed CS, Canada CI 6 CI 73 CI 86 CI 98 TI 80 TI 86 pproved Rated life Mechanical Electrical life Duty cycles per hour life C-3 C-3 load Operations Operations Operations CI x 0 6 x

5 Electrical life curves Contactors CI load categories, C- Contactors CI , load categories C-3 & C4 0% C-4 Mixed operation of squirrel-cage motors; U e = V Contactors CI , load categories C-4 Switching of squirrel-cage motors; U e = V Contactors CI , load categories C-3 Switching of squirrel-cage motors while starting; U e = V : Electrical life in millions of make/break operations B: Rated Operating current () 5

6 Tripping graphs TI 80 / 86 Explanation of graphs Mean value curves Upper curve: 3-phase tripping and asymmetric load tripping at min. setting. Lower curve: symmetric load tripping at max. setting. When tripping from the operationally warm condition, the tripping times are approx. 30% of the values shown. These values apply at an ambient temperature = 20 C. 3-phase tripping: x = symmetric load tripping: x = measured current rated motor current measured current max. scale value on overload relay Tripping time 2 < T p 0 s at 7.2 I e class 0 Note! In general, the thermal overload relay is always set on motor full load current. 3-phase overload ) Measure overload current 2 ) Find the overload factor (x) by dividing the measured value by the set value of the thermal overload relay (motor full load current). 3 ) Find (x) on the horizontal axis and follow a line vertically up until it intersects the upper curve. 4 ) From the intersection point, follow a horizontal line to the left and read off on the vertical axis the time that will elapse before the thermal overload relay cuts out the motor. symmetric load tripping ) Measure the current the motor draws from one of the intact phases. 2 ) Find the overload factor (x) by dividing the measured value by the maximum scale value of the thermal overload relay. 3 ) Find (x) on the horizontal axis and follow a line vertically up until it intersects the lower curve. 4 ) From the intersection point, follow a horizontal line to the left and read off on the vertical axis the time that will elapse before the thermal overload relay switch off the motor. 6

7 Contact symbols and terminal marking uxiliary contacts uxiliary contacts CBD - uxiliary contacts CBD - 22 uxiliary contacts CBD S - NO uxiliary contacts CBD S - NC uxiliary contacts CBD S - uxiliary contacts CBD S - 20 Contactors and thermal overload relay Contactors CI 6/73/86/98 Thermal overload relay TI 80/86 7

8 Connections, main contacts and contactor coils Connection method Single EN Multicore Without terminal sleeve With terminal sleeve Tightening torque CI 6, CI 73, CI 86, CI 98 Screw and box terminal TI 80, TI 86 Screw and box terminal Coil Screw and clamp washer [Nm] Loads Direct start, load categories C-2, C-3, C-4 Switching of 3-phase Motors; (50 Hz); mbient temperature 60 C, C-2, C-3, C-4 Rated loads at 50Hz V 240 V V 45 V 500 V 690 V CI kw CI kw CI kw CI kw Star-delta start, load category C-3 Star-delta start, load category C-3 Rated Loads at 50Hz V 240 V V 45 V 500 V 690 V CI kw CI kw CI kw CI kw Three-phase ohmic load, load category C- C- ctive Power Load (50 Hz) Operating temperatur max. 40 C (open condition) Heat-resistant cable only (min 75 C) V 240 V V 45 V 500 V 690 V CI 6, CI73, CI86 kw CI 98 kw Three-phase ohmic load, load category C- C- ctive Power Load (50 Hz) Operating temperatur max. 60 C (encl. condition) Heat-resistant cable only (min 75 C) V 240 V V 45 V 500 V 690 V CI 6, CI73, CI86 kw CI 98 kw Switching three-phase power transformers (C-6a) Switching of Power Transformers; C-6a (50 Hz) Transformer load, (factor n = 30, inrush current = n x rated transformer current) V 240 V V 45 V 500 V 690 V CI kw CI kw CI kw CI kw

9 Table (continued) Switching lighting Incandescent lamps (C-5b) Fluorescent lamps. individually compensated (C-5b) Max. operating current Max. operating current [] at operating tempereature ) Max. Capacity [uf] at Icc= [] 40 C 60 C 0k 20k 50k CI CI CI CI Switching capacitor loads, individual capacitors (C-6b) Inductance in leads between capacitors connected in parallel min. 6µH Max. Reactive power (kvr) ) V V 500 V 690 V 40 C 60 C 40 C 60 C 40 C 60 C 40 C 60 C CI CI CI CI Switching capacitor loads, regulating capacitors (C-6b) Inductance in leads between parallel-connected capacitors must be min.6µh Max. Reactive power (kvr) ) V V 500 V 690 V 40 C 60 C 40 C 60 C 40 C 60 C 40 C 60 C CI CI CI CI Switching direct current load at 60 C ambient temperature Load categories DC-3 and DC-5, contacts connected in series Max. operating current () DC-3. 3 poles in series DC-5. 3 poles in series 24 V 48 V 0 V 220 V 440 V 24 V 48 V 0 V 220 V 440 V CI CI CI CI Switching direct current load at 60 C ambient temperature Load category C-, contacts connected in series Max. operating current () 24 V 48 V V 440 V pole 2 poles 3 poles pole 2 poles 3 poles pole 2 poles 3 poles pole 2 poles 3 poles pole 2 poles 3 poles CI CI CI CI Contact resistance and power loss Typical impedance per pole [mω] Power loss at 3 poles Coil consumption a.c. [W] C-3 [W] Total power loss CI CI CI CI C- [W] Short-time withstand current I cw Current transfer time 0 sec. Short time withstand current in mps (Icw) Min cooling Time (min.) CI CI CI CI ) 40 C is defined as non-enclosed installation 60 C is defined as enclosed installation 9

10 Table (continued) Connections, auxiliary contacts CBD-, CBD S- For CI Connection method Single and multi core without term. sleeve High capacity with term. sleeve Tightening torque [Nm] Screw and clamp washer TI 80, TI 86 Screw and clamp washer uxiliary contacts, load categories C-5 and C- Max. operating current [] Comments C- 5 C V 240 V V 45 V 500 V 690 V 40 C ) 60 C ) CBD- For contactors CI CBD S- For contactors CI ) 40 C is defined as non-enclosed installation 60 C is defined as enclosed installation uxiliary contacts, load categories DC-2, DC-3, and DC-4 Max. operating current [] Comments DC-2 DC-3 DC-4 24 V 48 V 0 V 220 V 440 V 24 V 48 V 0 V 220 V 440 V 24 V 48 V 0 V 220 V 440 V CBD- For contactors CI CBD S- For contactors CI Coils, consumption and operating times CI Inrush power Holding-power Pull-in voltage Drop-out voltage Make time Break time a.c. a.c. a.c. a.c. a.c. a.c. V W V W V V ms ms (0.85-.) x U S (0.3-0) x U S RC Element (charge suppressor) Max. load control circuit (contact system) TI 80 TI 86 Comments Overvoltage factor n = U max U n RCD Suitable for contactors CI 6,73,86-3 Load Max. fuse C-5 DC-3 gl, gl, gg BS 88 type T 500 V, 2, 200 V 250 V, 2, 20 W 4 6 UL / CS Specifications UL/CS approved loads Motor load (C-3) [hp] Other loads (C-) [] -phase 3-phase UL CS 5 V 230 V 200 V 240 V 460 V 575 V 40 C ) 60 C ) 40 C ) 60 C ) CI CI CI CI ) 40 C is defined as non-enclosed installation 60 C is defined as enclosed installation uxiliary contacts, UL/CS approved loads Load capacity Comments a.c. d.c. Category V Category W CBD- and CBD S- For contactors CI Q Connections, main contacts Connection method Single and multi core (WG) Tightening torque (lb-in) CI 6, CI 73, CI 86, CI 98 Screw and clamp washer TI 80, TI 86 Screw and clamp washer

11 Dimensions Contactor CI 6, 73, 86, 98 Contactor CI 6, 73, 86, 98 built together with thermal overload relay TI Drilling dimensions CI 6, 73, 86, 98 with mechanical interlock Thermal overload relays TI 80 and TI 86 for contactors CI 6, 73, 86 Thermal overload relays TI 80 and TI 86 Thermal overload relay TI 80/ TI 86 on base plate Danfoss /S, (C-MCI / jmn),

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads. C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

Technical Information

Technical Information Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Series CA5 Contactors

Series CA5 Contactors Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower

More information

The contactor for large horsepower applications

The contactor for large horsepower applications Series The complete contactor for heavy industrial applications from 500HP to 900HP R Series contactors provide large horsepower performance with a design that is up to 40% smaller than traditional contactors

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

A200 NEMA Contactors and Starters A200

A200 NEMA Contactors and Starters A200 Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

Technical Information

Technical Information Electrical Data C7-9 Rated Insulation Voltage U i IEC, S,BS,SEV, VDE 0660 [V] 690V UL; CS [V] 600V Rated Impulse Voltage U imp [kv] 8kV Rated Voltage U e -Main Contacts C7 3-Pole Contactors C7-2 C7-6 C7-23

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose Contactors General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Contactors Series C8 Miniature Contactors and Starters... 3

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Series C8 Miniature and Starters... 3 ccessories... 2 Contactor Cross

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads 22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil

More information

ADS7 AC Contactor Starters

ADS7 AC Contactor Starters ADS7 AC Contactor Starters ADS7 starters fully comply with BS EN 60947-4-1, IEC 60947-4-1 and VDE 0660. The range offers a multitude of configurations and optional features including a complete choice

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Industrial contactors CTX-1

Industrial contactors CTX-1 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

Controls. CONTACTORS CWB Line (up to 40A)

Controls. CONTACTORS CWB Line (up to 40A) Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88. Motor Starters Star-Delta Starters Open Type 86 Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88 Accessories 89 Reversing Contactors 90 Pole Changing Starters 92 Technical Data 94 Wiring

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical) MODULAR DEVICES The range of two, three and four pole isolator switches are of a modular design and fit on DIN 50022 rail. Terminal capacity is 25mm 2. Isolator Switches Rating Poles Modules Reference

More information

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories Thermal Overload Relay J7TKN ) Thermal Overload Relay Direct and separate mounting Single phasing sensivity according to IEC 60947-4-1 Finger proof (BGV A2) Accessories Set for single mounting Approved

More information

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions Installation Contactors Z-SCH These switching devices have been designed and rated particularly for modular installation in modular distribution boxes for electrical installation or cabinets with device

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw THREE-POLE CONTACTORS series HR09-HR3 up 6 kw USE Series HR contacrs are particularly suitable for controlling mors, heating elements and three-phase and single-phase loads in general. OPERATION AND INSTALLATION

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Series CA6 Contactors

Series CA6 Contactors Series C6 Contactors classic contactor for demanding applications from 75 to 600HP (@460V) - 100 to 700HP (@ 575V) This series is being replaced by the C9 Series of contactors Sprecher + Schuh s C6 contactor

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

General_technical_data Series

General_technical_data Series Slow-make switching element Switching system The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The

More information

Capacitor Switching Contactors Type K3...-A, K3...-K

Capacitor Switching Contactors Type K3...-A, K3...-K Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Page 2-4 Page 2-8. Page Page 2-12

Page 2-4 Page 2-8. Page Page 2-12 Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

A7 Magnetic Contact/Switch CONTENTS

A7 Magnetic Contact/Switch CONTENTS A7 Magnetic Contact/Switch CONTENTS A7-02 Magnetic Contact / Switch VMC9~85 Medium/Small Capacity VITZRO Magnetic Contact/Switch provides customers with the safety as the first priority which is the core

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

W Datasheet: DIN Rail Contactors, series AMPARO

W Datasheet: DIN Rail Contactors, series AMPARO W Datasheet: DIN Rail Contactors, series AMPARO W SCHRACK-INFO For suiting of fans, pumps, heating & lighting Noise reducing design Low vibration on DIN-rail 230V 50/60Hz oder 24V 50/60 Hz coil DIN-Rail

More information

Mini Contactors. Technical Catalogue. Type B6, B7 ABB

Mini Contactors. Technical Catalogue. Type B6, B7 ABB Technical Catalogue Mini Contactors Type B6, B7 ABB ABB Mini contactors B6/4 kw; B7/5.5 kw Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T7DU Contents Mini contactors

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

MS25 59 MS RI RI RV 60, RV 120 RS 76 CDB3X 77 Surface Mounted (INO) and Flush Munted (IPO) Compact Distribution Boards 78

MS25 59 MS RI RI RV 60, RV 120 RS 76 CDB3X 77 Surface Mounted (INO) and Flush Munted (IPO) Compact Distribution Boards 78 index Contents: Page New Products 4 Contactors K03, K07 Mini Contactors 10 BR6 Thermal overload relay 16 KNL6 - KNL30 Contactors 18 KNL6G - KNL30G Contactors 25 KNL40, KNL 65 Contactors 29 KNL80 - KNL110

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Modular Contactors and Switches D681E121

Modular Contactors and Switches D681E121 Modular Contactors and Switches D681E121 Modular Contactors and Switches Modular Contactors 2, 3 Aux. contact block 3 Accessories 3 Day Night Reloading Contactors 4 Safety Switches 5 Main Switches Emergency

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102 Overloadrelay,10-16A,1N/O+1N/C Partno. ZB12-16 Articleno. 290168 CatalogNo. XTOB016BC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Frame size ZB12 Phase-failure sensitivity IEC/EN 60947,

More information

Quality Products, Prompt Service, Trustful Relationships.

Quality Products, Prompt Service, Trustful Relationships. SINCE 1989 www.kmindustrialcorp.com Quality Products, Prompt Service, Trustful Relationships. KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors Contents 0 - Contactors Selection guides.............................................page /2 b General, selection of contactors....................... pages /16 k contactors and reversing contactors b

More information

SWITCHGEAR. 4G cam switches

SWITCHGEAR. 4G cam switches SWITCHGEAR 178 4G cam switches ENERGY SAFELY SWITCHED 179 SWITCHGEAR 180 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear

More information

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Overloadrelay,10-16A,1N/O+1N/C. Articleno Overloadrelay,10-16A,1N/O+1N/C Partno. ZB32-16 Articleno. 278452 CatalogNo. XTOB016CC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Product range Accessories Accessories Overload relays

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Manual Motor Protectors

Manual Motor Protectors 88 Manual Motor Protectors 51 30 UP TO IMM16 Frame IMM32 Frame IMM65 Frame E468295 E468295 High interrupt capacity up to 100k (with optional current limiter) Din rail mounting Lockable handle (OFF position)

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. c Standard power ratings Rated Instantaneous Basic reference. Weight of 3-phase motors operational auxiliary

More information

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry. Protection Equipment Overload Relays Reference Manual 04/2011 Industrial Controls Answers for industry. Protection Equipment 2 3 7 7 8 9 14 1 16 17 18 18 19 20 2 26 27 28 29 30 32 37 38 40 42 Introduction

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information