1 d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. c Standard power ratings Rated Instantaneous Basic reference. Weight of 3-phase motors operational auxiliary Complete with code 50/60 Hz in category AC-3 current contacts indicating control (θ 55 C) in AC-3 circuit voltage (2) up to Fixing, 220V 380V 660V 0V cabling () 230V 400V 45V 0V 500V 690V kw kw kw kw kw kw A kg LC-D0900ii (3) LC-D090ii LC-D090ii LC-D200ii (3) LC-D20ii LC-D20ii LC-D090ii LC-D800ii (3) LC-D80ii LC-D80ii LC-D2500ii (3) LC-D250ii LC-D250ii LC-D3200ii (3) LC-D320ii LC-D250ii LC-D320ii LC-D40ii LC-D50ii LC-D65ii LC-D80ii (4) LC-D95ii.500 Note : Add-on auxiliary contact blocks and modules : see pages /32 to /43. LC-D95ii () For LC-D09 to D32 : clip-on mounting onto 35 mm " rail AM-DP. For LC-D40 to D95 : clip-on mounting onto 35 mm or 75 mm " rail AM-DL. Power terminals : LC-D09 to D95 protected against direct finger contact. Ready-to-tighten terminals. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts c / / Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5 60 Hz B6 D6 E6 F6 M6 U6 Q6 R6 50/60 Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 (3) 3-pole contactors without auxiliary contact (standard EN 5002). (4) 95 A rated operational current in AC-3 up to 400 V. Other versions Contactors with non-protected power terminals enabling power and control connections to be made using ring type terminals. Please consult your Regional customer centre.

2 d 3-pole contactors for motor control, 9 to 80 A Utilisation category AC-3 Control circuit : d.c. a Standard power ratings Rated Instantaneous Basic reference. Weight of 3-phase motors operational auxiliary Complete with code 50/60 Hz in category AC-3 current contacts indicating control (θ 55 C) in AC-3 circuit voltage (2) up to Fixing, 220V 380V 660V 0V cabling () 230V 400V 45V 0V 500V 690V kw kw kw kw kw kw A kg LP-D090ii LP-D090ii LP-D20ii LP-D20ii LP-D090ii LP-D80ii LP-D80ii LP-D250ii LP-D250ii LP-D320ii LP-D320ii LP-D40ii 2.00 LP-D320ii LP-D50ii LP-D65ii LP-D80ii Note : Add-on auxiliary contact blocks and modules, see pages /32 to /43. () For LP-D09 to D25 : clip-on mounting on 35 mm " rail AM-DP. For LP-D40 to D80 : clip-on mounting on 75 mm " rail AM-DL. Power terminals : LP-D09 to D80 protected against direct finger contact. Ready-to-tighten terminals. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts a U 0.8. Uc (3) JD BD CD ED ND SD FD GD MD UD RD U Uc (4) JW BW CW EW SW FW MW (3) LP-D40 to D80 : Uc. (4) LP-D40 to D80 : Uc. Other versions Contactors with non-protected power terminals enabling power and control connections to be made using ring type terminals. Please consult your Regional customer centre.

3 d 3 and 4-pole contactors for heating, lighting, etc., 25 to 25 A Utilisation category AC- Control circuit : a.c. Non inductive loads Number Instantaneous Basic reference. Weight Maximum operational of poles auxiliary Complete with code current contacts indicating control Utilisation category AC- circuit voltage (2) (θ 55 C) Fixing, cabling () A N/O N/C kg 25 3 LC-D0900ii or LC-D200ii (3) LC-D090ii or LC-D20ii (3) LC-D090ii or LC-D20ii (3) LC-D090ii 4 LC-D2004ii LC-D2008ii LC-D800ii LC-D80ii LC-D80ii LC-D2500ii LC-D250ii LC-D250ii LC-D2004ii 4 LC-D25004ii LC-D25008ii LC-D3200ii LC-D320ii LC-D320ii LC-D40ii.50 4 LC-D40004ii LC-D40008ii LC-D50ii.50 or LC-D65ii (3).50 LC-D65004ii 4 LC-D65004ii LC-D65008ii LC-D80ii.500 or LC-D95ii (3) LC-D80004ii LC-D80008ii.530 Note : Add-on auxiliary contact blocks and modules, see pages /32 to /43. () For LC-D09 to D32 : clip-on mounting on 35 mm " rail AM-DP. For LC-D40 to D95 : clip-on mounting on 35 mm or 75 mm " rail AM-DL. Power terminals : LC-D09 to D95 protected against direct finger contact. Ready-to-tighten terminals. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts c / / Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5 60 Hz B6 D6 E6 F6 M6 U6 Q6 R6 50/60 Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 (3) Selection according to number of operating cycles.

4 d 3 and 4-pole contactors for heating, lighting, etc., 25 to 25 A Utilisation category AC- Control circuit : d.c. Non inductive loads Number Instantaneous Basic reference. Weight Maximum operational of poles auxiliary Complete with code current contacts indicating control Utilisation category AC- circuit voltage (2) (θ 55 C) Fixing, cabling () A N/O N/C kg 25 3 LP-D090ii or LP-D20ii (5) LP-D090ii or LP-D20ii (5) LP-D2004ii LP-D2008ii LP-D090ii 32 3 LP-D80ii LP-D80ii LP-D250ii LP-D250ii LP-D25004ii LP-D25008ii LP-D320ii LP-D320ii LP-D320ii 60 3 LP-D40ii LP-D40004ii LP-D40008ii LP-D50ii 2.20 or LP-D65ii (5) LP-D65004ii LP-D65008ii LP-D80ii LP-D80004ii LP-D80008ii Note : Add-on auxiliary contact blocks and modules, see pages /32 to /43. () For LP-D2 to D32 : clip-on mounting on 35 mm " rail AM-DP. For LP-D40 to D80 : clip-on mounting on 75 mm " rail AM-DL. Power terminals : LP-D2 to D80 protected against direct finger contact. Ready-to-tighten terminals. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts a U 0.8. Uc (3) JD BD CD ED ND SD FD GD MD UD RD U Uc (4) JW BW CW EW SW FW MW (3) For LP-D40 to D80 : Uc. (4) For LP-D40 to D80 : Uc. (5) Selection according to number of operating cycles.

5 d 3 and 4-pole contactors Components for assembling reversing contactors and changeover contactor pairs (horizontally mounted), for customer assembly Combinations Contactors Mechanical interlocks Set of power connections Assembled Without With integral 3-pole reversing contactors 4-pole changeover using 2 identical electrical interlocking electrical interlocking contactor pairs contactors (2 N/C contacts) horizontally mounted, type : A A2 L 2 L2 3 4 L A A2 A2 A /L U V W 2 /L2 3 4 /L N /L N L A A2 L2 L3 N 2 2/L 2/L2 LC-D09 LA9-D09978 LA9-D0902 LA9-D269 LA9-D270 LC-D2 LA9-D869 LA9-D2570 LC-D8 LA9-D2569 LC-D25 LA9-D3269 LC-D32 LP-D09 LP-D2 LP-D8 LP-D25 LP-D32 LC-D40 LA9-D50978 LA9-D4002 LA9-D6569 LA9-D6570 LC-D50 LC-D65 LP-D40 LP-D50 LP-D65 LC-D80 LA9-D8069 LA9-D8070 LC-D95 LP-D80 LA9-D80978 LA9-D8002 LA9-D8069 LA9-D8070

6 d 3 and 4-pole contactors Components for assembling reversing contactors and changeover contactor pairs (horizontally mounted), for customer assembly c or a Component parts (including mechanical interlock with integral electrical interlocking) With Set of power connections Mechanical interlock 2 identical Reference Weight Kit reference Weight contactors () kg kg For assembly of 3-pole reversing contactors for motor control LC/LP-D09iiii LA9-D LA9-D LC/LP-D2iiii LC/LP-D8iiii LA9-D LA9-D LC/LP-D25iiii LA9-D LA9-D LC/LP-D32iiii LA9-D LA9-D LC/LP-D40ii LA9-D LA9-D LC/LP-D50ii LC/LP-D65ii LC-D80ii LA9-D LA9-D LP-D80ii LA9-D LA9-D LC-D95ii LA9-D LA9-D For assembly of 4-pole changeover contactor pairs for distribution (3-phase + neutral distribution system) LC/LP-D2004ii LA9-D LA9-D LC/LP-D25004ii LA9-D LA9-D LC/LP-D40004ii LA9-D LA9-D LC/LP-D65004ii LC-D80004ii LA9-D LA9-D LP-D80004ii LA9-D LA9-D Component parts (including mechanical interlock, without electrical interlocking) For assembly of 3-pole reversing contactors for motor control LC/LP-D090ii LA9-D LA9-D LC/LP-D20ii LC/LP-D80ii LA9-D LA9-D LC/LP-D250ii LA9-D LA9-D LC/LP-D320ii LA9-D LA9-D LC/LP-D40ii LA9-D LA9-D LC/LP-D50ii LC/LP-D65ii LC-D80ii LA9-D LA9-D LP-D80ii LA9-D LA9-D LC-D95ii LA9-D LA9-D For assembly of 4-pole changeover contactor pairs for distribution (3-phase + neutral distribution system) (2) LC/LP-D2004ii LA9-D LA9-D LC/LP-D25004ii LA9-D LA9-D LC/LP-D40004ii LA9-D LA9-D LC/LP-D65004ii LC-D80004ii LA9-D LA9-D LP-D80004ii LA9-D LA9-D

7 Thermal overload relays d 3-pole thermal overload relays (class 0 A) adjustable from 0. to 93 A, for motor protection Thermal overload relays to be used with fuses Thermal overload relays - compensated with manual or automatic reset, - relay trip indicator, - for a.c. or d.c. Relay Fuses to be used For direct Reference Weight setting with selected relay mounting range Type beneath contactor am gg (BS88) LC, LP A A A kg Class 0 A () LR2-D3ii LR2-D23ii D09 D32 LR2-D D09 D32 LR2-D D09 D32 LR2-D D09 D32 LR2-D D09 D32 LR2-D D09 D32 LR2-D D09 D32 LR2-D D09 D32 LR2-D D09 D32 LR2-D D09 D32 LR2-D D09 D32 LR2-D D2 D32 LR2-D D8 D32 LR2-D D25 and D32 LR2-D D25 and D32 LR2-D D32 LR2-D D40 D95 LR2-D D40 D95 LR2-D D40 D95 LR2-D D50 D95 LR2-D D50 D95 LR2-D D65 D95 LR2-D D80 and D95 LR2-D D95 LR2-D pole thermal overload relays for use with unbalanced loads Class 0 A : Change the prefix in the references above from LR2 to LR3. Example : LR3-D30. () Standard IEC specifies a tripping time for 7.2 times the setting current I R : class 0 A : between 2 and 0 seconds. LR2-D33ii Other versions Thermal overload relays - for distribution circuits, - with flat terminals for ring type connectors (except LR2-D3365). Please consult your Regional customer centre. LR2, LR3-D Independent mounting on 50 mm centres Independent mounting on 0 mm centres Remote trip or electrical reset or on rail AM-DP200 or DE LA7-D064 43,5 d 79 AM-DP200 AM-DE200 d () Can be mounted on RH or LH () + 5 mm for LR2-D5ii side of relays LR2, LR3-D 4 2xØ4, /60() 08 LA7-D DX-AP25 2xØ6,5 0 LA7-D03 () 96 34

8 Thermal overload relays d 3-pole thermal overload relays (class 20) adjustable from 0. to 93 A, for motor protection LR2-D5ii Thermal overload relays to be used with fuses Thermal overload relays - compensated with manual or automatic reset, - relay trip indicator, - for a.c. or d.c. Relay Fuses to be used For direct Reference Weight setting with selected relay mounting range Type beneath contactor am gg (BS88) LC, LP A A A kg Class 20 () LR2-D25ii D09 D32 LR2-D D09 D32 LR2-D D09 D32 LR2-D D09 D32 LR2-D D2 D32 LR2-D D8 D32 LR2-D D25 and D32 LR2-D D25 and D32 LR2-D D40 D95 LR2-D D40 D95 LR2-D D40 D95 LR2-D D50 D95 LR2-D D50 D95 LR2-D D65 D95 LR2-D D80 and D95 LR2-D () Standard IEC specifies a tripping time for 7.2 times the setting current I R : class 20 : between 6 and 20 seconds. LR2-D35ii Other versions Thermal overload relays - for distribution circuits, - with flat terminals for ring type connectors. Please consult your Regional customer centre. LR2, LR3-D2 Independent mounting on 50 mm centres Independent mounting on 0 mm centres Remote trip or electrical reset device or on rail AM-DP200 or DE LA7-D ,5 d xØ4, /60 08 LA7-D2064 DX-AP26 AM-DP200 AM-DE200 () Can be mounted on RH or LH d side of relays LR2, LR3-D2 LR2, LR3-D3 Independent mounting on 50 mm centres Independent mounting on 0 mm centres Remote trip or electrical reset device or on rail AM-DP200 or DE200 LA7-D LA7-D LA7-D xØ6, LA7-D03 () 29 LA7-D03 () 2 5,5 d xØ4, /87 23,5 3 AM-DP200 AM-DE200 () Can be mounted on RH or LH side d of relays LR2-D, LR3-D3 26 3xØ6,

9 Thermal overload relays d 3-pole thermal overload relays adjustable from 0. to 93 A Accessories (to be ordered separately) Description For use on Sold in Unit Weight overload relays lots of reference kg rminal blocks () LR2-D LA7-D for clip-on mounting on LR3-D 35 mm rail (AM-DP200) LR2-D2 LA7-D or screw fixing. LR3-D2 See pages /26 and /27 LR2-D3 LA7-D3064 (2) for fixing centres LR3-D3 Power terminals adaptor LR2-D LA7-D for mounting an LRi-D3 LR3-D overload relay beneath an LC-D40, D50 or D65 contactor Mounting plates (3) LR2-D 0 DX-AP for screw fixing LR3-D on 0 mm centres LR2-D2 0 DX-AP LR3-D2 LR2-D3 LA7-D LR3-D3 Marker holder LR2-D 00 LA7-D snap-in LR3-D Bag of 400 labels LA9-D (blank, self-adhesive) 7 x 6 mm Locking device LR2-D 0 LA7-D for Stop button LR3-D Remote tripping and LR2-D LA7-D03i (5) electrical reset device (4) LR3-D Remote control Reset function By flexible cable LR2-D LA7-D (length 0.5 m) LR3-D Stop and/or Reset function For fitting, remove the terminal protection shrouds and order the following 3 products : Adaptor LR2-D LA7-D for door mounted operator LR3-D Rod (snap-off end to obtain required LR2-D 0 ZA2-BZ length between 7 and 20 mm) LR3-D Operating head LR2-D ZA2-Biiii (6) 0.02 for spring return pushbutton LR3-D () rminal blocks are supplied with terminals protected against direct finger contact. Ready-to-tighten screws. (2) With terminals for ring type connectors, the reference becomes LA7-D (3) Remember to order the terminal block corresponding to the overload relay size. (4) The time for which the coil of remote tripping and electrical resetting device LA7-D03 can remain energised depends on its rest time : s pulse duration with 9 s rest time ; 5 s pulse duration with 30 s rest time ; 0 s pulse duration with 90 s rest time ; maximum pulse duration of 20 s with a rest time of 300 s. Minimum impulse time : 200 ms. (5) Reference to be completed by adding the coil voltage code. Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts c / /400 45/0 50/60 Hz B E F M Q N Consumption, inrush and sealed : < 00 VA Volts a J B E DD F M Consumption, inrush and sealed : < 00 W. (6) Reference to be completed, please refer to chapter 5. LA7-D020 Adaptor for door mounted operator c 0 Stop Reset LA7-D305 Reset by flexible cable Mounting with cable straight LA7-D305 Mounting with cable bent LA7-D020 e c c : adjustable from 7 to 20 mm c : up to 550 mm e : up to 20 mm e : up to 20 mm e M0x

10 Thermal overload relays d 3-pole thermal overload relays adjustable from 0. to 93 A Scheme, setting-up Scheme LR2-D LR3-D 3 5 RESET{ Auto. Man TEST STOP Setting-up the special functions of LR2-D and LR3-D thermal overload relays Setting the relay Manual-Automatic selection ,5 TEST 8 A LR2 D 3 M STOP RESET A U T O 5 4 RESET A U T O RESET A U T O NO NC Manual reset Automatic reset i Lift the transparent cover to gain access to the settings and controls. i Adjustment is achieved by turning dial 2 which is graduated directly in Amperes. i The setting can be locked by sealing 3 of the cover. i After having lifted the transparent cover, the type of reset operation can be selected by turning the blue RESET selector 4 : - turn to the left for manual reset, - push and turn to the right for automatic reset. The selector is then held in the automatic position and is released by turning the selector to the left (return to manual operation). i With the cover folded down, the selector is locked. i Manual resetting of the relay is achieved by pressing the blue RESET button. Stop function 5 st function 6 STOP ET A U T O RESET A U T O TEST Stop Locking st Trip indicator i The Stop function is obtained by pressing the red STOP button 5. i Pressing the STOP button : - actuates the N/C contact, - does not affect the N/O contact. i The STOP button can be locked by fitting a U clip (ref. LA7-D90). With the cover folded down, the device is locked. i The st function is obtained by pressing the red TEST button 6 with a screwdriver. i Operation of the TEST button simulates tripping of the relay and : - actuates both N/O and N/C contacts, - actuates the trip indicator 7.

11 Thermal overload relays d 3-pole thermal overload relays adjustable from 0. to 93 A Dimensions LR2, LR3-D Direct mounting beneath contactors LC-D09 to D32, LP-D09 to D32 and LP4-D2 e AM-DP200 AM-DE200 d b 47() 92 c d 8 7 g b () c e g LC-D09, D2, D LC-D LC-D LP-D09, D2, D LP-D LP-D LP4-D () + 5 mm for LR2-D5ii LR2, LR3-D2 Direct mounting beneath contactors LC-D25 and D32, LP-D25 and D32 59 b e AM-DP200 AM-DE200 d c d g b c e g LC-D LC-D LP-D LP-D LR2, LR3-D3 Direct mounting beneath contactors LC-D40 to D95 and LP-D40 to D80 AM-DL20 AM-DL200 d e 4 09 c b d g b c e g (3P) g (4P) LC-D LC-D LC-D LC-D LC-D LP-D LP-D LP-D LP-D

12 d 3 and 4-pole contactors, reversing and changeover contactors Auxiliary contact blocks and accessories Control circuit : a.c. Instantaneous auxiliary contact blocks () For use in normal operating environments Number Max. number of blocks per contactor Composition Reference Weight of Clip-on mounting contacts Front Side (D25 and D32) LA-DN or 2 (D40 D95) LA-DN (D09 D95) LA-DN kg 2 LA-DN LA-DN (D09 D95) LA8-DN LA8-DN (D09 D95) 2 2 LA-DN With terminal referencing conforming to standard EN LA-DN LA-DN LA-DN LA-DN (2) LA-DC (D090 D320) LA-DNM (D0900 D3200) LA-DNP (D40 D95) LA-DNG (D090 D320) 2 2 LA-DN22M (D0900 D3200) 2 2 LA-DN22P (D40 D95) 2 2 LA-DN22G Instantaneous auxiliary contact blocks with dust and damp protected contacts () For use in harsh industrial environments 2 (D09 D95) 2 LA-DX (3) LA-DY (D09 D95) 2 2 LA-DZ LA-DZ () Maximum mounting capacity, depending on type of coil. Device Coil Operation Maximum number of add-on blocks type type guaranteed Clip-on mounting from front side LC-D 50 or 60 Hz 0.8. Uc /60 Hz 0.8. Uc or Uc + 2 (2) Including N/O and N/C make before break. (3) Device fitted with 4 terminals for earth screen continuity.

13 d 3 and 4-pole contactors, reversing and changeover contactors Auxiliary contact blocks and accessories Control circuit : a.c. Time delay auxiliary contact blocks () Number Maximum number of Time delay Reference Weight of blocks per contactor Type Setting contacts Front clip-on mounting range kg N/O (D09 D95) On-delay 0. 3 s (2) LA2-DT N/C s LA2-DT s LA2-DT s (3) LA2-DS Off-delay 0. 3 s (2) LA3-DR s LA3-DR s LA3-DR Mechanical latch blocks () Unlatching Clip-on Basic reference. Weight control front mounting To be completed (4) kg Manual LC-D09 D65 LA6-DK0i or electric LC-D80 D95 LA6-DK20i () Maximum mounting capacity, depending on type of coil. Device Coil Operation Maximum number of add-on blocks type type guaranteed Clip-on mounting from front side LC-D 50 or 60 Hz 0.8. Uc /60 Hz 0.8. Uc or Uc + 2 (2) With extended scale from 0. to 0.6 s. (3) With switching time of 40 ms ± 5 ms between opening of the N/C contact and closing of the N/O contact. (4) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts c or a /36 42/48 60/ /27 220/ / /45 Code J B C E EN K F M U Q

14 d 3 and 4-pole contactors, reversing and changeover contactors Auxiliary contact blocks and accessories Control circuit : d.c. Instantaneous auxiliary contact blocks () For use in normal operating environments Number Max. number of blocks per contactor Composition Reference Weight of Clip-on mounting contacts Front Side (D25 and D32) LA-DN (D40 D80) LA-DN (D09 D80) LA-DN LA-DN LA-DN (D09 D32) LA8-DN LA8-DN (D09 D80) 2 2 LA-DN LA-DN LA-DN LA-DN LA-DN (2) LA-DC Instantaneous auxiliary contact blocks with dust and damp protected contacts () kg For use in harsh industrial environments 2 (D09 D80) 2 LA-DX (3) LA-DY (D09 D80) 2 2 LA-DZ LA-DZ Time delay auxiliary contact blocks () Number Max. number of blocks per contactor Time delay Reference Weight of Clip-on mounting Type Setting contacts Front Side range(s) kg N/O (D09 D80) On 0. 3 (4) LA2-DT delay N/C LA2-DT Mechanical latch blocks (Manual or electric unlatching control) 0 80 LA2-DT (5) LA2-DS Off 0. 3 (4) LA3-DR delay LA3-DR LA3-DR Front clip-on Basic reference. Weight mounting To be completed (6) kg LP-D09 D65 LA6-DK0i LP-D80 LA6-DK20i () Either of the following may be fitted, as required: 2 side-mounting contact blocks or front mounting contact block. (2) Including N/O + N/C make before break. (3) Device fitted with 4 terminals for earth screen continuity. (4) With extended scale from 0. to 0.6 s. (5) With switching time of 40 ms ± 5 ms between opening of the N/C contact and closing of the N/O contact. (6) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts c or a /36 42/48 60/ /27 220/ / /45 Code J B C E EN K F M U Q

15 d 3 and 4-pole contactors, reversing and changeover contactors Accessories Electronic serial timer modules () Operational voltage (2) Time delay Reference Weight c LC- a LP V V V kg On-delay type D09 D32 D40 D95 D09 D s -DT0U Off-delay type.5 30 s -DT2U s -DT4U D09 D8 D25 D s -DR0U Interface modules ().5 30 s -DR2U s -DR4U Operational voltage Supply Reference Weight c LC- a LP- voltage V V V V E-E2 (a) kg Relay interface D09 D95 24 V -DFBQ D09 D95 D09 D32 24 V -DFB Relay interface with manual override switch (output forced ON ) 48 V -DFE D09 D95 D09 D32 24 V -DLB Solid state interface 48 V -DLE D09 D32 D40 D95 24 V -DWB Auto-Man-Stop control modules () For local override operation tests with 2-position Auto-Man switch and O-I switch Operational voltage Reference Weight c LC- a LP V V V V kg D09 D95 D09 D32 -DMK D09 D95 D09 D32 -DMU Indicators (contactor state) Red LED For mounting on contactors Supply Sold in Unit Weight LC and LP voltage (c and a) lots of reference kg Clips into 2 72 V 5 -DVE 0.00 legend plate location on all contactor sizes V 5 -DVM V 5 -DVR 0.00 () Mounted at top on terminals A and A2 (screw fixing). (2) For 24 V operation, the contactor must be fitted with a 2 V coil (code Z). See pages /49 to /52.

16 d 3 and 4-pole contactors, type LC-D Dimensions LC-D09, D (2)(LA) 36(LA6-DK) 45() (LA2,LA3,LA6-DK2) 74 2,5 77(Di) 90(Di2) 45 2,5 97(3)(DF,DT) 05(3) (DM,DR,DW,DL) LC-D8 LC-D (2)(LA) 28(LA6-DK) 37() (LA2,LA3,LA6-DK2) 74 2,5 77(Di) 90(Di2) 45 2,5 97(3)(DF,DT) 05(3) (DM,DR,DW,DL) () + 4 mm with lead sealing kit () + 4 mm with lead sealing kit (2) With 2 or 4 contacts (2) With 2 or 4 contacts (3) With or without combined use of a coil suppressor module (3) With or without combined use of a coil suppressor module -DA, DE -DA, DE LC-D250, D250, D25004 LC-D (Di) 00(Di2) 07(3)(DF,DT) (DM,DR,DW,DL) 84 87(Di) 00(Di2) 07(3)(DF,DT) (DM,DR,DW,DL) (2)(LA) 36(LA6-DK) 45() (LA2,LA3,LA6-DK2) 2,5 56 2,5 5(3) (2)(LA) 4(LA6-DK) 50() (LA2,LA3,LA6-DK2) 2,5 56 2,5 5(3) () + 4 mm with lead sealing kit () + 4 mm with lead sealing kit (2) With 2 or 4 contacts; contact 20 (LA-DN0 or DN0) (2) With 2 or 4 contacts; contact 25 (LA-DN0 or DN0) (3) With or without combined use of a coil suppressor module (3) With or without combined use of a coil suppressor module -DA, DE -DA, DE LC-D40, D50, D65 28 LC-D80, D (Di2) 42(DF,DT) 50(DM,DR,DW,DL) 27 35(Di2) 42(DF,DT) 50(DM,DR,DW,DL) 2 4(4) 45(2)(LA) 64()(LA2,LA3,LA6-DK2) 2,5 (3) 2,5 2 25(4) 53(2)(LA) 72()(LA2,LA3,LA6-DK2) 2,5 (3) 2,5 () + 4 mm with lead sealing kit () + 4 mm with lead sealing kit (2) With 2 or 4 contacts; contact 39 (LA-DN0 or DN0) (2) With 2 or 4 contacts; contact 47 (LA-DN0 or DN0) (3) 75 : 3 poles, 85 : 4 poles (3) 85 : 3 poles, 96 : 4 poles (4) 25 : LC-Dii008 (4) 40 : LC-Dii008

17 d 3 and 4-pole contactors, type LP-D Dimensions LP-D09, D2 LP-D (Di) 90(Di2) 97(3)(DF,DT) 05(3)(DM,DL) 74 77(Di) 90(Di2) 97(3)(DF,DT) 05(3)(DM,DL) (2)(LA) 58(LA6-DK) 67()(LA2,LA3,LA6-DK2) 2,5 45 2, (2)(LA) 63(LA6-DK) 72()(LA2,LA3,LA6-DK2) 2,5 45 2,5 () + 4 mm with lead sealing kit () + 4 mm with lead sealing kit (2) With 2 or 4 contacts (2) With 2 or 4 contacts (3) With or without combined use of a coil suppressor module (3) With or without combined use of a coil suppressor module -DC, DE. -DC, DE. LP-D25 LP-D (Di) 00(Di2) 07(3)(DF,DT) 5(3)(DM,DL) 84 87(Di) 00(Di2) 07(3)(DF,DT) 5(3)(DM,DL) (2)(LA) 73(LA6-DK) 82()(LA2,LA3,LA6-DK2) 2,5 56 2, (2)(LA) 78(LA6-DK) 87()(LA2,LA3,LA6-DK2) 2,5 56 2,5 () + 4 mm with lead sealing kit () + 4 mm with lead sealing kit (2) With 2 or 4 contacts; contact : 57 (LA-DN0 or DN0) (2) With 2 or 4 contacts; contact : 62 (LA-DN0 or DN0) (3) With or without combined use of a coil suppressor module (3) With or without combined use of a coil suppressor module -DC, DE. -DC, DE. LP-D40, D50, D65 LP-D80 -Di3 -Di (4) 202(2)(LA) 22()(LA2,LA3,LA6-DK2) (3) 2 8(4) 20(2)(LA) 229()(LA2,LA3,LA6-DK2) (3) () + 4 mm with lead sealing kit () + 4 mm with lead sealing kit (2) With 2 or 4 contacts; contact : 96 (LA-DN0 or DN0) (2) With 2 or 4 contacts; contact : 204 (LA-DN0 or DN0) (3) 75 : 3 poles, 85 : 4 poles (3) 85 : 3 poles, 96 : 4 poles (4) 82 : LP-Dii008 (4) 96 : LP-Dii008

2.3 LA1-DN10, DN01 LA6-DK LA8-DN LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ

2.3 LA1-DN10, DN01 LA6-DK LA8-DN LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ 110-17V AC-DC 50/60Hz E1 E LA1-DN10, DN01 0 LA6-DK LA6 DK10 LA8-DN LA1-DN.3 LA8-DN LC1-LP1 LA1-DN, DC LA-DT, DS LA3-DR LA1-DX, DY, DZ See right-hand page for mounting possibilities according to the contactor

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors Contents 0 - Contactors Selection guides.............................................page /2 b General, selection of contactors....................... pages /16 k contactors and reversing contactors b

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

LR9 F OVERLOAD RELAYS

LR9 F OVERLOAD RELAYS Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.

More information

TeSys contactors. Characteristics. Environment Rated insulation voltage 5/50. Contactor type LC1 D09 D18 DT20 and DT25. DT60A and DT80A.

TeSys contactors. Characteristics. Environment Rated insulation voltage 5/50. Contactor type LC1 D09 D18 DT20 and DT25. DT60A and DT80A. Characteristics Contactor type LC1 D09 D18 DT20 and DT2 Environment Rated insulation voltage V 600 D2 D38 DT32 and DT40 D40A D6A DT60A and DT80A V 690 1000 D80 D9 D11 and D10 Rated impulse withstand voltage

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Pendant control stations 6

Pendant control stations 6 Characteristics For control circuits Environment Conformity to standards EN/IEC 0-- EN/IEC 00-, UL 0, CSA C- n EN/IEC 0-- and EN/ISO 0: 00 for versions with trigger action Emergency stop Protective treatment

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

References 4 Fuse carriers

References 4 Fuse carriers References components 000_ -pole basic blocks Rating Cartridge fuse size umber of early break contacts () Single-phase protection device () Reference () Connection by spring terminals A 0 x 8 () Without

More information

DATA SHEET LC-D CONTACTORS

DATA SHEET LC-D CONTACTORS Issued November 2009 DATA SHEET LC-D CONTACTORS Based on Shneider MKTED205103EN Catalogue Charateristis 5 d Contator type LC1 D09 D18 D25 D38 D40 D50 D95 D115 and D150 DT20 and DT25 DT32 and DT40 Environment

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

TeSys D Overload Relays

TeSys D Overload Relays TeSys D Contactors and Overload Relays TeSys D Overload Relays Table.24: TeSys D Overload Relays Ambient Compensated, Bimetallic, Direct Mounting Current Setting Range (A) For Direct Mounting to LC1...

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Motor control The essential guide

Motor control The essential guide Motor control The essential guide Motor control TeSys Accurate and reliable control of motors TeSys range provide you more simplicity, compactness, openness and flexibility... so many evolutions and new

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015 Low Voltage EasyPact TVS Motor starters from 6A to 630A Catalog 2015 Designed for the essential EasyPact TVS General contents EasyPact TVS contactors, 6 A to 630 A A-1 EasyPact TVS thermal overload relays

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated AF09... AF3 3-pole contactors 4 to 1.5 kw, AC / DC operated AF09-30-10 AF09... AF3 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors

More information

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A Characteristics Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600, CSA A600-Q600 Standard version : TH Ambient air

More information

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors.

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Characteristics TeSys contactors 0 Model d

Characteristics TeSys contactors 0 Model d Charateristis TeSys ontators 0 Model d Contator type LC1 D09 D18 D25 D38 D40 D50 D95 D115 and D150 DT20 and DT25 DT32 and DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 60947-4-1, V 690

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

Low Voltage. TeSys B contactors. Variable composition contactors, new design. Catalogue

Low Voltage. TeSys B contactors. Variable composition contactors, new design. Catalogue Low Voltage TeSys B contactors Variable composition contactors, new design Catalogue TeSys B contactors Contents Application 2 Selection guide 4 Characteristics A-1 Accessories A-13 Dimensions and installation

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

Industrial contactors CTX-1

Industrial contactors CTX-1 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical

More information

Enclosed motor starters

Enclosed motor starters Direct-on-line starters Without thermal overload relay (1) Direct-on-line starters Composite steel/plastic enclosure. Ingress protection: IP 65 Maximum Maximum kw rating Control Reference Weight current

More information

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw THREE-POLE CONTACTORS series HR09-HR3 up 6 kw USE Series HR contacrs are particularly suitable for controlling mors, heating elements and three-phase and single-phase loads in general. OPERATION AND INSTALLATION

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

Quality Products, Prompt Service, Trustful Relationships.

Quality Products, Prompt Service, Trustful Relationships. SINCE 1989 www.kmindustrialcorp.com Quality Products, Prompt Service, Trustful Relationships. KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com TeSys D, K Catalogue 2017 'S335' series contactors for electrodomestic applications schneider-electric.com Presentation TeSys D, TeSys K TeSys D, TeSys K: S335 series Best-in-class contactors for electrodomestic

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

Low voltage switch gear

Low voltage switch gear Low voltage switch gear Omron is an established global manufacturer of low voltage switch gear (LVSG) products, and the company s new series (J7) complements the existing portfolio. High power-handling

More information

Command and signalling E 250, E 259 selection table

Command and signalling E 250, E 259 selection table E 250, E 259 selection table Latching relays E250 Installation relays E259 Contacts switching on each impulse sent to the control coil. Contacts maintained in switched position only while the control coil

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h No Filter 81.6 % Auto 9.1 m3/h 250.0 m3/h Auto 99.7 m3/h 100.0 m3/h Auto 91.3 m3/h 92.0 m3/h Auto 40.0 m3/h 7. MW Auto 50.7 m3/h 50.0 m3/h 7.2 % Auto.6 % 45.0 % ABB NF Contactor Relays Overview...3 Ordering

More information

Accessories for Contactors and Contactor Relays

Accessories for Contactors and Contactor Relays 4/0 Accessories for Contactors and Contactor Relays Contents Accessories for A... Series and BC... Series Contactors and for Contactor Relays Auxiliary Contact Blocks - Front Mounting... 4/2 Auxiliary

More information

Enclosed Starters. Contents. Motor nominal powers and current... 20/2. Panorama... 20/3. Starting of three-phase asynchronous motors...

Enclosed Starters. Contents. Motor nominal powers and current... 20/2. Panorama... 20/3. Starting of three-phase asynchronous motors... Enclosed Starters 20 Contents Motor nominal powers and current... 20/2 Panorama... 20/3 Starting of three-phase asynchronous motors... 20/4 Ordering Details Enclosed D.O.L starters - Protection by thermal

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC Product data sheet Characteristics LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- - Guard Lock Safety-door Switch Polymer housing, IP65, and slow-action contacts with positive opening. 2 versions Mechanical lock/solenoid release Solenoid lock/mechanical release Rotatable operating head

More information

MS25 59 MS RI RI RV 60, RV 120 RS 76 CDB3X 77 Surface Mounted (INO) and Flush Munted (IPO) Compact Distribution Boards 78

MS25 59 MS RI RI RV 60, RV 120 RS 76 CDB3X 77 Surface Mounted (INO) and Flush Munted (IPO) Compact Distribution Boards 78 index Contents: Page New Products 4 Contactors K03, K07 Mini Contactors 10 BR6 Thermal overload relay 16 KNL6 - KNL30 Contactors 18 KNL6G - KNL30G Contactors 25 KNL40, KNL 65 Contactors 29 KNL80 - KNL110

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Pendant control stations

Pendant control stations : pages 30075/3 to 30075/6 Characteristics Environment Conforming to standards IEC 947-5-1, EN 60 947-5-1, IEC 337-1, VDE 0660-200 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600,

More information

AF09... AF96 3-pole contactors Accessory fitting details

AF09... AF96 3-pole contactors Accessory fitting details AF9... AF96 3-pole contactors Accessory fitting details Contactor and main accessories (other accessories available) AF9... AF65 AF contactor (without top mounted coil terminal block) VEM4 mechanical and

More information

Thermal overload relays Type TA Class 10

Thermal overload relays Type TA Class 10 Thermal overload relays Type TA Class Thermal Overload relays Description Available for starter construction with A Line contactors and separate panel mounting Designed for close couple mounting Separate

More information

References Contactors 0 Reversing contactors for motor control in utilisation category AC-3 (115 to 265 A), pre-assembled Controlcircuit:a.c.ord.c.

References Contactors 0 Reversing contactors for motor control in utilisation category AC-3 (115 to 265 A), pre-assembled Controlcircuit:a.c.ord.c. s Contactors 0 Reversing contactors for motor control in utilisation category AC- ( to A), pre-assembled Controlcircuit:a.c.ord.c. 89 LC F -pole reversing contactors (horizontally mounted) () Pre-wired

More information

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics LC1F400E7 Complementary [Uimp] rated impulse withstand voltage Overvoltage category [Ith] conventional free air thermal current Main Range Product name Product or component

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC Product datasheet Characteristics LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

Partnership that you can trust. LV Switchgear Motor Control Products.

Partnership that you can trust. LV Switchgear Motor Control Products. s Partnership that you can trust LV Switchgear Motor Control Products Maximum etail Price w.e.f. st October, 204 www.siemens.co.in s SIMOCODE pro S Get your motor control center s intelligent and compact

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives Safety Interlock Switches DSL Compact -Contact uard Lock Safety-Door Switch Two types are available: a connector type that reduces wiring time and a detachable terminal block type. Robust and durable metal

More information

Bimetal Overload Relays 3UA and 3UC

Bimetal Overload Relays 3UA and 3UC 32 Bimetal Overload Relays 3UA and 3UC The 3UA / 3UC thermal overload relays are suitable for customers from all industries, who want guaranteed optimum inverse time delayed protection of their electrical

More information