SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

Size: px
Start display at page:

Download "SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC"

Transcription

1 SIRCO PV IEC The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar load break switches. Making and breaking capacity under load conditions up to 1500 VDC. These extremely durable switches have been tested and approved for use in the most demanding applications. They have been designed and tested for all types of applications: earthing, floating or bipolar. > Patented switching technology up to 500 VDC/pole > Positive break indication > Up to 1500 VDC as per characteristics by IEC > Up to 4 branch circuits per switch Conformity to standards > IEC > IEC > UL 98 (1) dvantages (1) Veuillez nous consulter. Optimiseyour investment Thanks to a reduced number of bridging bars, you can limit your costs and save mounting time. 2 pole SIRCO PV will reduce warming and can be placed in a smaller enclosure. High quality materials SIRCO PV is an extremely robust device in a glass fibre reinforced polyester frame. This material provides: high mechanical strength, stability to temperature variations (RTI of 130 C), high dielectric strength (high CTI / tested as per standard STM D 2303). Take advantage of an innovative design The SIRCO PV can be directly connected to up to four independent PV panel strings. The global solution cost is therefore reduced in comparison with the use of four distinct switches. Reliability and performance Our range of SIRCO PV load break switches is compliant to standards UL98 and IEC SIRCO PV have been tested to critical currents and at a 10 k shortcircuit during 50 ms without specific protection. The type of cable protection against voltage surges can therefore be selected. pprovals and certifications (1) (1) Product reference on request. 132 General Catalogue

2 SIRCO PV IEC Typical PV architecture The SIRCO PV range provides safe disconnection and isolation at all levels within your PV installation. SIRCOPV 054 The SOCOMEC solutions Combiner box LEVEL OF INSTLLTION SOCOMEC SOLUTIONS SIRCO PV One circuit up to 500 at 1500 VDC Recombiner box SIRCO PV 4 circuits up to 500 at 1000 VDC 2 circuits up to 500 at 1500 VDC Inverter SIRCO PV One circuit up to 3200 at 1000 VDC up to 2000 at 1500 VDC General Catalogue

3 SIRCO PV IEC References 1000 VDC ack plate mounting Rating () size poles Switch body Direct handle External handle 1 PV circuit P 26PV 2010 Shaft for external handle Quantity to be ordered to connect 2 poles in series P 26PV P 26PV P 26PV P 26PV P 26PV 4050 J1 type S2 type (1) IP IP IP mm mm mm x P 26PV P 26PV P 26PV P 26PV P Please consult us C2 type PV circuits S4 type (1) IP IP V1 type IP mm mm mm mm mm x Please consult us DS 4 P 26PV DS 4 P 26PV DS 4 P 26PV 5025 J2 type DS 4 P 26PV P 27PV 4032 J1 type P 27PV S2 type (1) IP IP IP mm mm mm DS 8 P 26PV 8063 J2 type DS 8 P 26PV DS 8 P 26PV DS 8 P 26PV DS 8 P 27PV DS 8 P 27PV DS 8 P 27PV 8039 C2 type PV circuits J2 type V1 type IP S2 type (1) IP IP IP mm mm mm mm x (1) Defeatable handle. 134 General Catalogue

4 SIRCO PV IEC VDC ack plate mounting Rating () size poles Switch body Direct handle External handle 1 PV circuit P 27PV P 27PV P 27PV DS 8 P 26PV 8063 J2 type S2 type (1) IP IP IP Shaft for external handle 200 mm mm mm Quantity to be ordered to connect 2 poles in series DS 6 DS 7 DS 8 P 8 P 8 P 26PV PV PV 8200 C2 type DS 6 P 27PV DS 6 P 27PV DS 6 P 27PV PV circuits J2 type V1 type IP S2 type (1) IP IP IP mm mm mm mm (1) Defeatable handle. ccessories Direct operation handle size Handle type Handle colour Reference 4 7 J J C C DS 5 DS J DS 5 DS J DS 7 DS C DS 7 DS C acces_335_a_2_cat acces_153_a_2_cat Door interlocked external operation handle Use Door interlocked external operation handles include an escutcheon, are padlockable and must be utilised with an extension shaft. In a combiner box, located close to the solar cell strings, or located close to the inverter, we recommend to use a door interlocked external handle for its safety features. Front operation EExample The locking function of the enclosure in the "ON" position will force the operator to safely disconnect and isolate the solar cell strings prior to any intervention. Opening the door when the switch is on "ON" position is possible by defeating the locking function using a tool (authorised persons only). The interlocking function is restored when the door is reclosed. size Handle type Handle colour Degree of protection Reference DS S2 IP DS S2 IP DS S2 IP DS 6 7 S4 IP DS 6 7 S4 IP DS 7 DS V1 IP acces_150_a_2_cat Reinforced S2 type handle J1 type handle acces_152_a_2_cat S4 type handle C2 type handle access_189_a_2_cat V1 type handle General Catalogue

5 SIRCO PV IEC ccessories (continued) Shaft for external handle Use Standard lengths: Other lengths: Please consult us. 200 mm, 320 mm, 400 mm. size Handle type Dimension Y (mm) Length (mm) Reference 4 S S S S S S S S S S S S DS S DS S DS S DS S DS S DS S DS V DS V DS V DS V V V X acces_144_b_1_cat acces_369_a_1_cat acces_202_a_1_x_cat Shaft guide for external operation Use To guide the shaft extension into the Required for a shaft length over 320 mm. external handle. This accessory enables the handle to engage the extension shaft with a misalignment of up to 15 mm. Description Reference Shaft guide acces_260_a_2_cat 136 General Catalogue

6 SIRCO PV IEC Stype handle adapter Use Enables Stype handles to be fitted in place of existing older style Socomec handles. dapter can also be utilised as a spacer to increase the distance between the panel door and the handle lever. Dimensions dds 12 mm to the depth of the handle. Handle colour External IP (1) To be ordered in multiples of Reference IP (1) IP: protection degree according to IEC standard. acces_187_a_1_cat lternative Stype handle cover colours Use For single lever handles type S1, S2, S3. Other colours: Please consult us. Handle colour Handle type To be ordered in multiples of Reference Light grey S1, S2, S Dark grey S1, S2, S Light grey S Dark grey S acces_198_a_1_cat uxiliary contact Use Prebreak and signalling of positions 0 and I: 1 to 2 NO/NC auxiliary contacts, 1 to 4 NO NC auxiliary contacts, 1 to 2 low level NO/NC auxiliary contacts. Characteristics NO/NC C: IP2 with front operation. Connection to the control circuit y 6.35 mm faston terminal. Electrical characteristics operations. NO/NC changeover auxiliary contacts size Position C Type Reference contact NO/NC contacts NO/NC DS 7 DS 1 contact NO/NC DS 7 DS 2 contacts NO/NC acces_076_a_1_cat Low level NO/NC auxiliary contacts size Position C Type Reference contact NO/NC contacts NO/NC NONC contact size Position C Type Reference contact NO NC contacts NO NC Terminal screen Use Top and bottom protection against direct contact with terminals or connection parts. size No. of poles Position Pack Reference 4 2 P Top or bottom 1 unit P Top or bottom 1 unit P Top or bottom 1 unit P Top or bottom 1 unit P Top or bottom 1 unit P Top or bottom 1 unit P Top or bottom 1 unit DS 2 P Top or bottom 1 unit DS 6 P Top and bottom 2 units DS 8 P Top and bottom 2 units DS 8 P Top and bottom 2 units DS 8P Top and bottom 2 units acces_079_a_1_cat General Catalogue

7 SIRCO PV IEC ccessories (continued) ridging bars for connecting poles in series Use The bridging bars will make easy the connection of the poles in series, allowing the following configurations (1). (1) Other connections: refer to mounting instructions VDC size Rating () Quantity to be ordered to connect 2 poles in series Fig. Reference 1 PV circuit (1) (1) (1) (1) (1) (1) (1) (1) Consult us 2 PV circuits 4 DS 100 (1) (1) 4 DS 160 (1) (1) 4 DS 250 (1) (1) 4 DS 315 (1) (1) DS DS DS DS PV circuits 5 DS VDC size Rating () Quantity to be ordered to connect 2 poles in series Fig. Reference 1 PV circuit DS DS DS DS PV circuits 5 DS DS DS (1) ridging bars not needed. 138 General Catalogue

8 SIRCO PV IEC ridging bars for connecting poles in series (continued) acces_374_a_1_x_cat Fig. 1 acces_376_a_1_x_cat Fig. 3 acces_386_a_1_x_cat acces_378_a_1_x_cat acces_374_a_1_x_cat Fig. 2 Fig.4 Fig. 5 General Catalogue

9 SIRCO PV IEC Characteristics Characteristics according to IEC Rated current In Thermal current at 40 C () Thermal current at 50 C () Thermal current at 60 C () Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) pole(s) in series size I e () pole(s) in series circuits Rated voltage Utilisation category I e () size 1 circuit 1000 VDC DC P ; 1 P 2 P P ; 1 P 2 P 4 1 circuit 1500 VDC DC P ; 1 P 4 P 4 DS P ; 1 P 4 P 4 DS 2 circuits 1000 VDC DC P ; 1 P 4 P 4 DS P ; 1 P 4 P 4 DS Shortcircuit capacity (without protection) Rated shorttime withstand current 0.3 s. (k eff) Rated shorttime withstand current 1 s. (k eff) 5 5 Connection Maximum Cu rigid cable crosssection (mm²) Maximum Cu busbar width (mm) Tightening torque min (Nm) Tightening torque max (Nm) Mechanical characteristics Durability (number of operating cycles) Operating effort (Nm) Weight of a 2 pole device (kg) Weight of a 4 pole device (kg) Rated current In Thermal current at 40 C () Thermal current at 50 C () Thermal current at 60 C () Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) pole(s) in series size I e () pole(s) in series circuits Rated voltage Utilisation category I e () size 1 circuit 1000 VDC DC P ; 1 P 2 P P ; 1 P 3 P 5 1 circuit 1500 VDC DC P ; 1 P 4 P 4 DS P ; 1 P 3 P 5 2 circuits 1000 VDC DC P ; 1 P 4 P 4 DS P ; 1 P 6 P 5 DS 2 circuits 1500 VDC DC P ; 1 P 6 P 5 DS 4 circuits 1000 VDC DC P ; 1 P 8 P 5 DS Shortcircuit capacity (without protection) Rated shorttime withstand current 0.3 s. (k eff) Rated shorttime withstand current 1 s. (k eff) 5 5 Connection Maximum Cu rigid cable crosssection (mm²) Maximum Cu busbar width (mm) Tightening torque min (Nm) Tightening torque max (Nm) Mechanical characteristics Durability (number of operating cycles) Operating effort (Nm) Weight of a 2 pole device (kg) 1.8 Weight of a 3 pole device (kg) 6 Weight of a 4 pole device (kg) 4.3 Weight of a 6 pole device (kg) 12.3 Weight of an 8 pole device (kg) General Catalogue

10 SIRCO PV IEC Characteristics according to IEC (continued) Rated current In Thermal current at 40 C () Thermal current at 50 C () Thermal current at 60 C () Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) circuits Rated voltage (1) For a rated operational voltage Ue = 400 VC. (1) For a rated operational voltage Ue = 400 VC. Utilisation category I e () pole(s) in series size I e () pole(s) in series 1 circuit 1000 VDC DC P ; 1 P 2 P P ; 2 P 4 P 4 1 circuit 1500 VDC DC P ; 1 P 3 P P ; 1 P 3 P 5 2 circuits 1000 VDC DC P ; 1 P 4 P 4 DS P ; 1 P 4 P 5 2 circuits 1500 VDC DC P ; 1 P 6 P 5 DS 4 circuits 1000 VDC DC P ; 1 P 8 P 5 DS Shortcircuit capacity (without protection) Rated shorttime withstand current 0.3 s. (k eff) 10 Rated shorttime withstand current 1 s. (k eff) 5 10 Rated peak withstand current (k peak) (1) Connection Maximum Cu rigid cable crosssection (mm²) Maximum Cu busbar width (mm) Tightening torque min (Nm) Tightening torque max (Nm) Mechanical characteristics Durability (number of operating cycles) Operating effort (Nm) Weight of a 2 pole device (kg) 1.8 Weight of a 3 pole device (kg) 6 6 (4) / 3.8 (5) Weight of a 4 pole device (kg) Weight of a 6 pole device (kg) 12.3 Weight of an 8 pole device (kg) 15 Rated current In Thermal current at 40 C () Thermal current at 40 C () Thermal current at 60 C () 4: 475 / 5: Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) circuits Rated voltage Utilisation category I e () pole(s) in series size I e () pole(s) in series 1 circuit 1000 VDC DC P ; 2 P 4 P P ; 2 P 4 P 5 1 circuit 1500 VDC DC P ; 1 P 3 P P ; 4 P 8 P 5 DS 2 circuits 1000 VDC DC P ; 1 P 4 P P ; 2 P 8 P 5 DS 2 circuits 1500 VDC DC P ; 1 P 6 P 5 DS 4 circuits 1000 VDC DC P ; 1 P 8 P 5 DS Shortcircuit capacity (without protection) Rated shorttime withstand current 1 s. (k eff) Connection Maximum Cu rigid cable crosssection (mm²) 2x150 2x185 Maximum Cu busbar width (mm) Tightening torque min (Nm) Tightening torque max (Nm) Mechanical characteristics Durability (number of operating cycles) Operating effort (Nm) Weight of a 3 pole device (kg) 6 (4) / 3.8 (5) Weight of a 4 pole device (kg) Weight of a 6 pole device (kg) 12.3 Weight of an 8 pole device (kg) size size General Catalogue

11 SIRCO PV IEC Characteristics (continued) Characteristics according to IEC (continued) Rated current In Thermal current at 40 C () Thermal current at 50 C () Thermal current at 60 C () 5: 650 / 6: Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) pole(s) in series pole(s) in series circuits Rated voltage Utilisation category I e () size I e () size 1 circuit 1000 VDC DC P ; 2 P 4 P P ; 2 P 4 P 6 1 circuit 1500 VDC DC P ; 4 P 8 P 6 DS P ; 4 P 8 P 6 DS 2 circuits 1000 VDC DC P ; 2 P 8 P 6 DS P ; 2 P 8 P 6 DS Shortcircuit capacity (without protection) Rated shorttime withstand current 1 s. (k eff) Connection Maximum Cu rigid cable crosssection (mm²) 2x240 2x240 Maximum Cu busbar width (mm) Tightening torque min (Nm) Tightening torque max (Nm) Mechanical characteristics Durability (number of operating cycles) Operating effort (Nm) Weight of a 4 pole device (kg) Weight of an 8 pole device (kg) Rated current In Thermal current at 40 C () Thermal current at 50 C () Thermal current at 60 C () Rated insulation voltage U i (V) 1500 Rated impulse withstand voltage U imp (kv) 12 pole(s) in series pole(s) in series circuits Rated voltage Utilisation category I e () size I e () size 1 circuit 1000 VDC DC P ; 2 P 4 P P ; 2 P 4 P 8 1 circuit 1500 VDC DC P ; 4 P 8 P 7 DS 2 circuits 1000 VDC DC P ; 2 P 8 P 7 DS Shortcircuit capacity (without protection) Rated shorttime withstand current 1 s. (k eff) Connection Maximum Cu busbar width (mm) x 100 x 5 Tightening torque min (Nm) Tightening torque max (Nm) Mechanical characteristics Durability (number of operating cycles) Operating effort (Nm) Weight of a 4 pole device (kg) Weight of an 8 pole device (kg) General Catalogue

12 SIRCO PV IEC Pole connections in series 1 PV circuit 1000 VDC 1 PV circuit 1500 VDC 4 2P 48 4P 5 3P 5 DS 7 DS 8P () () () () () sirco_075_a_1_x_cat () 1 () sirco_076_a_1_x_cat () () 1 () () sirco_077_a_1_x_cat () () 1 () sirco_077_a_1_x_cat () () 1 2 PV circuits 1000 VDC 4 DS 4P 5 4P 5 DS 7 DS 8P () () 1 2 () () () () () () () () () () () () sirco_082_a_1_x_cat sirco_079_a_1_x_cat () 2 PV circuits 1500 VDC () () 1 1 () 5 DS 6P () () () 2 () 2 () () sirco_080_a_1_x_cat () () () 1 2 () sirco_083_a_1_x_cat sirco_081_a_1_x_cat 4 PV circuits 1000 VDC 5 DS 8P () () () () () () () () 1 2 () () () () () () () () 3 4 () 1 () () () 2. Front switch.. Rear switch. 1. Utility 1 2. Utility 2 3. Utility 3 4. Utility 4 General Catalogue

13 SIRCO PV IEC Dimensions (mm) 4 5 J 1 Ø 9 4 J1 7.5 Ø 7 Y Ø 11 K2 K K1 H H 20 Ø 13 sirco_068_a_1_x_cat J2 J3 C and 500 excepted. size No. of poles C H J J1 J2 J3 K K1 K2 Y 4 2 P P P P P DS 5 DS Ø Ø 7 C 4 DS 25 J1 J Y Y Ø K1 5 DS Ø H K H sirco_069_a_1_x_cat J3 J2 H1 size No. of poles C H H1 J J1 J2 J3 K K1 Y Y1 4 DS 4 P DS 6 P DS 8 P General Catalogue

14 SIRCO PV IEC J C J1 Y H H K2 K K 65 4 x Ø16 Ø 9 sirco_070_a_1_x_cat 80 H1 size No. of poles C H H1 J J1 K K1 K2 Y 6 4 P DS J J1 Y1 C Y 11 K K H H 65 4 x Ø16 sirco_071_a_1_x_cat 80 H1 size No. of poles C H H1 J J1 K K1 Y Y1 6 ds 8 P General Catalogue

15 SIRCO PV IEC Dimensions (mm) (continued) 7 J1 J Y C Ø DS J1 J Y C Y1 K K1 9 H H K2 K1 sirco_073_a_1_x_cat K H H 120 H1 size No. of poles C H H1 H2 J J1 K K1 K2 Y 7 4 P Ø12.5 sirco_074_a_1_x_cat 120 H1 size No. of poles C H H1 J J1 K K1 Y Y1 7 DS 8 P Dimensions of SIRCO PV VDC 8, please consult us. 146 General Catalogue

16 SIRCO PV IEC Dimensions for external handles (mm) 4 4 DS 5 Handle type S2 type Front operation Direction of operation 0 Door drilling 40 Ø Ø 7 poign_013_a_1_gb_cat I Ø DS 6 7 Handle type S4 type Front operation Direction of operation Door drilling I Ø78 90 Ø 37 poign_036_a_1_gb_cat Ø DS 7 DS Handle type V1 type Front operation Direction of operation I Door drilling 50 4 Ø 6.5 poign_037_a_1_gb_cat Ø General Catalogue

17 SIRCO PV IEC ridging bars (mm) DS sircoul_030_a_1_x_cat Ø11 sircoul_062_b_1_x_cat Ø sircoul_031_a_1_x_cat Ø sircoul_062_a_1_x_cat Ø sircoul_032_a_1_x_cat Ø 9 5 sircoul_034_a_1_x_cat Ø General Catalogue

18 SIRCO PV IEC Mounting orientation ll frames 4 DS 5 DS 6 DS 7 DS sircoul_028_a_1_x_cat sirco_271_a_1_x_cat sirco_271_a_1_x_cat General Catalogue

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 new sircopv_059_a cat The solution for > Combiner box > Recombiner box > Inverter Function SIRCO PV UL98 non fusible disconnect switches are heavy duty

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics

More information

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A Load break switches new SRCO-pv_023_a_1_cat The solution for > Residential buildings. > Buildings. > Solar parks. Strong points Function SRCO PV are manually operated multipolar load break switches. They

More information

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity

More information

What you need to know. Â Conformity to standards

What you need to know.  Conformity to standards SIRCO PV Load break switches for solar applications sirco_343_a_1_cat  What you need to know A solar electrical installation is an application that requires switching devices fully meet the needs of operational

More information

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points Transfer switches svr_151_a The solution for > Manufacturing industry > Power distribution SRCOVER 2 Strong points > complete range > Easy connections > Stable positions svr_125_a_1_cat Bypass TS 0 Conformity

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed site_317_a sirco-ul_22_b_cat sirco-ul_4_b_cat 1A to 2A - 6VDC and 1VDC UL98B Listed  Function non fusible disconnects are heavy duty switches that break and make 6VDC or 1VDC photovoltaic circuits on

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M and MV Universal load break switches from 16 to 160 A SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A Conformity to standards (1) Changeover switches svr-ul_14_b_1_cat > EC 6947-3 > UL98, Guide WHTY, file 1138 > UL18, Guide WPYV, file 31792 > CSA 22.2#4, Class 4651-2 (1) Product reference on request. svr_136_a_2_cat

More information

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A TyS t M - TyS g M utomatic Transfer Switching Equipment Transfer switches new The solution for > High Rise uildings > Data centre > Healthcare buildings TyS g M I-0-II P atys-mg_001_b_1_cat Function TyS

More information

An innovative technology

An innovative technology The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,

More information

CATALOGUE MARINE APPLICATIONS. Energy performance solutions

CATALOGUE MARINE APPLICATIONS. Energy performance solutions CATALOGUE MARINE APPLICATIONS Energy performance solutions 2017 2018 Marine Certifications Our certified products As an independent manufacturer, we, at Socomec are committed to adapting the range and

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

Switching, control and protection solutions for solar applications

Switching, control and protection solutions for solar applications Switching, control and protection solutions for solar applications continuous performance www.socomec.com Summary SIRCO M PV Manually operated modulable and modular switches p. 4 SIRCO MV PV Manually

More information

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They

More information

SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200A

SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200A 2017 CTLOGUE extract SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200 Transfer switches svr_207_a.eps svr_208_a.eps The solution for > Manufacturing > Power

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

Motorised and automatic transfer enclosed switchess

Motorised and automatic transfer enclosed switchess s Integrated products and solutions coff_538_a.eps atysm_251_b_1_cat.eps The solution for > igh-rise buildings > Data centers > Energy generation > ealthcare buildings > Banks and insurance companies >

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

General Characteristics

General Characteristics from 63 to 31 lbs_037_a he solution for > ain switchboard > Distribution panel > Emergency switching > us tie Function he CEC ensures making and breaking on load and security breaking of any low voltage

More information

MANUALLY OPERATED CHANGEOVER SWITCHES

MANUALLY OPERATED CHANGEOVER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application: NORMA/EMERGENCY Application: UPS,

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A Transfer switches Accessories Terminal shrouds IPX protection against direct contact with terminals or connecting parts. Advantages Perforations allow remote thermographic inspection without the need to

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A Integrated products & solutions The solution for > Iron and steel industry > Cement plants > Paper mills > Sawmills > Hydraulic power packs > Automotive > Mining coff_436_a coff_434_a Strong points Function

More information

SHORT FORM CATALOGUE. ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98

SHORT FORM CATALOGUE. ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98 2014 2015 SHORT FORM CATALOGUE ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98 ATyS UL 1008 Motorized Transfer Switching Equipment from 100 to 400 A Transfer switches

More information

Safety enclosures. 482 General Catalogue SOCOMEC. Safety enclosures

Safety enclosures. 482 General Catalogue SOCOMEC. Safety enclosures coff_163_a_1_cat coff_156_b_1_cat Function equipped with SOCOMEC switches provide emergency breaking, breaking for mechanical maintenance and safety isolation in the vicinity of any low voltage final circuit.

More information

Microswitches MK series

Microswitches MK series Microswitches MK series Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica. These products have been designed with

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

FOOT SWITCHES

FOOT SWITCHES - 83 - FOOT SWITCHES PS... / PD... Foot Switches Double insulation - Plastic Casing IP65 Description Applications Foot switch operated machines such as: shearing machines, spinning machines, spinning lathers,

More information

SFS-UFS Single Foot Switches

SFS-UFS Single Foot Switches SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination

More information

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block. PNE ISOTORS Craig & Derricott has a range of products designed specifically for control panel and switchboard construction. Most panels require a means of electrical isolation and the can offer variants

More information

CATALOGUE. Solutions for Power, Control & Safety

CATALOGUE. Solutions for Power, Control & Safety CATALOGUE Solutions for Power, Control & Safety 2015 Contents An independent manufacturer... p.4 Four key applications: the benefit of a specialist... p. 5 A cutting-edge laboratory... p. 6 Socomec in

More information

Enclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes

Enclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes Protection and Connection Enclosed DC rated switchdisconnectors OTDCP from 16 to 32 Amperes Enclosed OTDC switches from 16 to 32 Amperes meet the demanding requirements of photovoltaic applications. Enclosed

More information

Low Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201

Low Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201 Low Voltage Products SwitchLine OT change-over switches 160, 200, 0, 315, 400, 630 and 800 mps Catalogue OT7G 05_09 1SCC301012C0201 Ith / Ie /C22, 415V Ie /C23, 415V OT160E OT160E_W OT200E OT200E_W OT0E

More information

Single foot switches - PX and PA series

Single foot switches - PX and PA series Single foot switches - PX and PA series Description The PX and PA foot switches are traditional products of Pizzato Elettrica that have recorded a continuous growth and success in the market. Modified

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33 BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference Load Break Switches According to BS EN60947-3 High Thermal & Dynamic Strength Fully rated suitable for distribution & motor loads Auxiliary contacts also available Fully Visible Breaking Arduous categories

More information

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Protection and Connection Motorized and automatic transfer switches IEC Technical guide Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

Changeover & Bypass Sw it ches

Changeover & Bypass Sw it ches Changeover & Bypass Switches St ate of the art Manufacturing Facilit ies Haridw ar, Noida Ph-I & Noida Ph-II Plant Changeover & Bypass Sw it ches Introduction On Load Changeover Switches (with & without

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Transfer switching solutions

Transfer switching solutions CATALOGUE EXTRACT Transfer switching solutions from 40 to 6300 A 2018 Contents The SOCOMEC Group... Security and reliability for your transfer applications... Remotely operated and Automatic Transfer

More information

FUSIBLE DISCONNECT SWITCHES

FUSIBLE DISCONNECT SWITCHES FUSIBLE DISCONNECT SWITCHES HIGHLIGHTS: Double break contacts per pole up to 400 A Touch safe fuse covers/line shrouding standard Service Entrance Rated Compact Footprints Front operated switches Side

More information

IP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description.

IP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description. General Description Supplied in hinged lid grey powder coated sheet steel enclosures, these IP41 sealed assemblies are eminently suitable for most indoor industrial applications. Supplied as Switch-Disconnectors

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

I Ex-Safety switches I

I Ex-Safety switches I 3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX

More information

LOAD BREAK SWITCHES AND SWITCH FUSES

LOAD BREAK SWITCHES AND SWITCH FUSES easy to install LOAD BREAK SWITCHES AND SWITCH FUSES Sixty years of innovation in developing and producing high-quality switches When Mr Kauko Hyryläinen founded KATKO in 1941, one of his key targets

More information

Position Switches Series 8074/2

Position Switches Series 8074/2 www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,

More information

Item Parameter Value. 1. Rated operating voltage 123 [kv] 245 [kv] 420 [kv] 2500 [A] 3150 [A] 4000 [A] 2500 [A] 3150 [A] 4000 [A]

Item Parameter Value. 1. Rated operating voltage 123 [kv] 245 [kv] 420 [kv] 2500 [A] 3150 [A] 4000 [A] 2500 [A] 3150 [A] 4000 [A] Item Parameter Value 1. Rated operating voltage 13 [kv] 45 [kv] 40 [kv]. Rated continuous current 500 [] 3150 [] 4000 [] 500 [] 3150 [] 4000 [] 500 [] 3150 [] 4000 [] 3. Peak current 160 [k] 160 [k] 160

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Switch disconnectors

Switch disconnectors Selection Load break switch disconnectors type LK3, 40-120 A Selection guide for 3 and 4-pole switch disconnectors General The LK3 range of switch disconnectors (lth: 40 A to 120 A) is designed for use

More information

SWITCH DISCONNECTORS PLANET -SWITCH.

SWITCH DISCONNECTORS PLANET -SWITCH. SWITCH DISCONNECTORS 6A to 600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 50A. PLANET -SWITCH SEC. PAGE

More information

25A 25A 32A 40A 40A 63A 63A 80A

25A 25A 32A 40A 40A 63A 63A 80A ISDC Compact Range 25A - 200A Control Panel Isolation Equipment Craig & Derricott has ranges of Switch-Disconnectors, Fuse Combination Units and Changeover Isolators for panel mounting ranging from 25A

More information

Safety rope switch with reset for emergency stop

Safety rope switch with reset for emergency stop Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 ACTUATORS VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 FR FX FK FW 5 6 7 11 1 14 NC NC slow action slow

More information

Switch Disconnectors

Switch Disconnectors Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles

More information

Page 2-4 Page 2-8. Page Page 2-12

Page 2-4 Page 2-8. Page Page 2-12 Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V

More information

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems FUSERBLOC CD The universal Fuse Combination Switch FROM 20 TO 1250 A SOCOMEC GROUP SWITCHING PROTECTION & UPS Industrial Switching & Protection Systems SWITCHING FUSERBLOC CD THE UNIVERSAL FUSE COMBINATION

More information

Low Voltage Switches. Switches Motorized change-over switches OTM _C

Low Voltage Switches. Switches Motorized change-over switches OTM _C Low Voltage Switches Switches Motorized change-over switches OTM...12_C II I OTM 12_C Improves your permance OTM II I 0 OFF ON I 0 OFF II I ON I ssembly made easy Bridging bars quick wiring Tunnel terminals

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5 2.19 AZM 19 range 13 44 32 2,3 3 1 Features Voltage variants Approvals Thermoplastic enclosure Manual / Emergency release Long life Actuation on de-energisation or energisation Slim design, particularly

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

Load Break Disconnect Switches FSLBS

Load Break Disconnect Switches FSLBS Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS CONTACT BLOCKS FR FX FK FW 5 6 7 11 1 14 NC NC

More information