FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
|
|
- Betty Caldwell
- 5 years ago
- Views:
Transcription
1 Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved safety Function FUSOMAT are manually controlled tri- or tetrapolar fuse combination switches. They can be tripped remotely. They break or switch off on load and provide safety isolation and protection against overcurrent for any low voltage electrical circuit. Advantages Tripping upon overload Remote breaking by voltage release device. High breaking capacity Protection against overloads and shortcircuits thanks to high breaking capacity fuses (100 ka rms). They can automatically disconnect a circuit in combination with: fuse blown indication. thermal relay. protective relays DIRIS. other protective devices. Improved safety Double break per phase (top and bottom of fuse - up to 630 A (NFC/DIN) and 800 A (BS88). Visible break up to 630 A Positive break indication. IP2 protection with terminal shrouds front panel. A complete range > Can be combined with UR fuses for the protection of power semi-conductors. Please consult us. Conformity to standards > IEC > EN > VDE > NBN EN > BS 88 Configurations Functional diagram (for further details see the installation instructions supplied with the product) Direct front. 2. External front. 3. position AC. 4. AC wired to ready mounted transmission coil. 5. shrouds. 6. Fuse blown indication device fusom_060_b_1_x_cat 304 General Catalogue
2 References BS88 - Front and side - Switch body with a shunt trip coil VAC Fuse (1) No. of poles Front Switch body Side Switch body Direct (2) External Shaft for external Auxiliary contact position Auxiliary contact tripping shrouds (3) screens (4) Inter phase barrier 250 A B1-B2-B3 400 A B1-B2- B3-B4 630 A C1-C2 800 A C1-C2-C A D Front Side S3 type Front Front mm st contact IP (2) contact 320 mm Red IP (2) 2 nd contact Side Side mm IP (2) Red IP55 Front Side (1) For the fuses: see "BS88 industrial fuselinks" page 338. (2) Standard. (3) Top/bottom. (4) Bottom terminals protection screen as standard. General Catalogue
3 References NFC and DIN - Front - Switch body with a shunt trip coil VAC Fuse No. of poles Switch body Direct External Shaft for external Auxiliary contact position Auxiliary contact tripping 1 st Fuse blown AC shrouds (1 piece) screens top Inter phase barrier A / (2) 400 A / A / (1) S3 type IP (1) S3 type Red/yellow IP mm mm (1) 1 st contact nd contact contact (2) (2) (2) 800 A / A / (1) (3) (3) (1) Standard. (2) Top/bottom. (3) Bottom terminals protection screen as standard. 306 General Catalogue
4 NFC and DIN - Side - Switch body with a shunt trip coil VAC Fuse No. of poles Switch body Direct External Shaft for external Auxiliary contact position Auxiliary contact tripping 1 st Fuse blown AC shrouds (1 piece) screens top Inter phase barrier 250 A / (2) 400 A / A / A / (2) S3 type 1 st contact IP (2) (1) contact 200 mm (1) S3 type 2 nd contact Red (2) IP (3) A / (3) (1) Standard. (2) Top/bottom. (3) Bottom terminals protection screen as standard. General Catalogue
5 Accessories Direct Front Handle colour Reference Red consult us Side Handle colour Reference Red acces_156_a_2_cat External Front Handle type Handle colour External IP Reference S3 IP S3 Red IP Side Handle type Handle colour External IP Reference S3 IP S3 Red IP acces_151_a_1_cat acces_166_a_2_cat S-type adapter S3 type S3 type Enables S-type s to be fitted in place of existing older style Socomec s. Dimensions Adds 12 mm to the depth of the. To be ordered Handle colour in multiples of External IP (1) Reference 1 IP (1) IP: protection degree according to IEC standard. acces_187_a_1_cat Alternative S-type cover colours For single lever S3 type s. Other colours: Please consult us. Colour To be ordered in multiples of Handle Reference Light grey 50 S3 type Dark grey 50 S3 type Light grey 50 S4 type Dark grey 50 S4 type acces_198_a_2_cat Shaft for external Standard lengths: mm mm. Other lengths: Please consult us. Front Dimension (mm) Shaft length (mm) Type Reference x x x x Side Dimension Y (mm) Shaft length (mm) Type Reference x acces_202_a_1_x_cat Y acces_144_b_1_cat acces_203_a_1_x_cat 308 General Catalogue
6 Auxiliary contact Pre-break and signalling of positions 0 and I: 1 to 2 auxiliary contacts. Coil tripping 1 to 2 auxiliary contacts. Connection to the control circuit By 6.35 mm fast-on terminal. Characteristics Auxiliary contact IP2. Electrical characteristics s. position contact Operating current I e (A) Current 250 VAC 400 VAC 24 VDC 48 VDC nominal (A) AC-13 AC-13 DC-13 DC contact signalling coil tripping Operating current I e (A) Current 250 VAC 400 VAC 24 VDC 48 VDC nominal (A) AC-13 AC-13 DC-13 DC position contact Position AC Reference st AC nd AC rd and more consult us low level position contact Position AC Reference st AC nd AC contact signalling coil tripping Position AC Reference AC acces_048_a_1_cat Alternative tripping coil Shunt trip coil Replacement tripping coil Modified Original coil Voltage Reference Reference 24 VAC VAC VAC VAC included 400 VAC VDC VDC VDC / 200 VDC VDC Undervoltage trip coil Replacement tripping coil Modified Original coil Voltage Reference Reference 24 VAC VAC VAC VAC VAC VDC VDC VDC VDC VDC Omnipolar breaking remotely controlled by shunt trip or undervoltage voltage release coil. Note: the shunt trip coil must not be supplied for more than 5 s. A 230 VAC shunt trip coil is fitted to the standard switch body. To modify this coil, the reference opposite must be added to the switch reference. Examples for ordering: FUSOMAT with shunt trip coil 230 VAC - 1 reference: FUSOMAT 250 A, 3 pole, front, reference FUSOMAT fitted with a non standard coil - 2 references: FUSOMAT 250 A, 3 pole, front, fitted with a 110 VAC undervoltage trip coil: Shunt trip coil acces_050_a_1_cat acces_049_a_1_cat General Catalogue
7 Accessories (continued) Current-reducing resistor for undervoltage trip coil Reduces, by limiting the current, the effects on the undervoltage coils used in continuous processes or processes exposed to high ambient temperatures. Voltage Reference 110 VAC VAC VAC VDC Fuse blown indication For DIN fuse cartridge with striker. Electrical principle A auxiliary contact detects that the fuse has blown. Connection to the control circuit By 6.35 mm fast-on terminal. Electrical characteristics s. Characteristics Operating current I e (A) Current 250 VAC 400 VAC 24 VDC 48 VDC nominal (A) AC-13 AC-13 DC-13 DC changeover contact No. of poles Position AC Reference st st st st st st / 2 nd shrouds Top or bottom protection against direct contact with terminals or connection parts. Advantage Perforations allowing remote thermographic inspection without removal. No. of poles Position Reference top or bottom (1) top or bottom (2) 630 top or bottom (1) 630 top or bottom (2) (1) Reference composed of 3 pieces. (2) Reference composed of 4 pieces. acces_213_b_1_cat screen Top or bottom protection against direct contact with terminals or connecting parts. No. of poles Position Reference top top / bottom included fusom_059_a_1_cat 310 General Catalogue
8 Cage terminals Connection of bare copper cables onto the terminals (without lugs). References Rating max (A) No. of poles Reference acces_053_a_1_cat Connections Flexible cable cross-section (mm 2 ) Rigid cable cross-section (mm 2 ) Width flexible bar (mm) Stripped over (mm) Dimensions A A1 C R Ø 1 Z M16 14 acces_091_a_1_x_cat ø Z A1 acces_092_a_1_x_cat C A R M M20 15 Handle key interlocking accessories Locking in position 0 of the front or side : using a padlock (not supplied) and factory integrated into the. using RONIS 1104 A lock (key BC 3318) to be mounted directly on the padlockable. Locking using CASTELL K (not supplied) Locking using RONIS EL11AP (not supplied). Locking using RONIS EL 1104 A lock (supplied) Operation Reference front direct Locking using RONIS EL11AP lock (not supplied) Operation Reference external front direct Locking using CASTELL lock (not supplied) Operation Reference external Label holder Recognisable self-adhesive label allowing identification of the devices. Lock RONIS 1104 A acces_010_b_1_x_cat Dimensions W x H (mm) To be ordered in multiples of Reference 18 x acces_044_a_1_cat Other specific accessories Customised protection screens (for specific dimensions or high ambient temperatures). Connection accessories. Mounting plates for standard systems. Special construction available for specific environments. General Catalogue
9 Characteristics according to IEC to 1250 A Thermal current I th (40 C) 250 A 400 A 630 A 800 A 1250 A NFC/DIN fuse size Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Rated al currents Ie (A) Rated voltage Utilisation category A/B (1) A/B (1) A/B (1) A/B (1) A/B (1) 400 VAC AC-21 A / AC-21 B 250/ / / / / VAC AC-22 A / AC-22 B 250/ / / / / VAC AC-23 A / AC-23 B 250/ / / / / VAC (2) AC-21 A / AC-21 B 200/ / / / / VAC (2) AC-22 A / AC-22 B 200/ / / / / VAC (2) AC-23 A / AC-23 B 200/ / / / / VDC DC-21 A / DC-21 B 200/ / / / / VDC DC-22 A / DC-22 B 200/ / / / / VDC DC-23 A / DC-23 B 200/ / / / / VDC DC-21 A / DC-21 B 200/ / /630 (3) 800/800 (4) 800/1250 (4) 440 VDC DC-22 A / DC-22 B 200/ /315 (3) 315/630 (3) 800/800 (4) 800/1250 (4) 440 VDC DC-23 A / DC-23 B 200/ /315 (3) 400/630 (3) 800/800 (4) 800/1000 (4) Operational power in AC-23 (kw) At 400 VAC without pre-break in AC-23 (kw) (1)(5) 132/ / / / /560 At 690 VAC without pre-break in AC-23 (kw) (1)(5) 185/ / / / /600 Reactive power (kvar) At 400 VAC (kvar) (5) Fuse protected short-circuit withstand (ka ms prospective) Prospective short-circuit (ka rms) (6) 80/100 80/100 80/100 80/100 80/100 Associated fuse rating (A) (6) Short-circuit capacity Rated peak withstand current (ka peak) (6) Connection Min. connection wire range x 150 Minimum Cu busbar section (mm 2 ) 2 x 30 x 5 2 x 60 x 5 2 x 60 x 5 Maximum Cu cable section (mm 2 ) x x x 185 Maximum Cu busbar width (mm) Tightening torque min (Nm) Mechanical characteristics Durability (number of operating cycles) Weight of a 3 pole device (kg) Weight of a 4 pole device (kg) (1) Category with index A = frequent - Category with index B = infrequent. (2) With terminal shrouds or phase barrier. (3) Poles cannot be juxtaposed. (4) 4-pole device with 2 pole in series by polarity. (5) The power value is given for information only, the current values vary from one manufacturer to another. (6) For a rated al voltage Ue = 400 VAC. 312 General Catalogue
10 Dimensions Front BS88 - FUSOMAT 250 to 800 A NFC and DIN - FUSOMAT 250 to 630 A Direct front External front P F M A Z U W Y 1 AC fusom_046_d_1_x_cat B AA BA N K1 V1 T J R 2 V2 190 H 1 C E min shrouds. 2. Reset 70. Dimensions shrouds Switch body Switch mounting Connection A 3p. A 4p. B C E AC F 3p. F 4p. H J 3p. J 4p. K1 M N P 3p. P 4p. R T U V1 V2 W 3p. 4p. Y Z AA BA ,5 570, ,5 425, ,5 570, ,5 425, BS88 - FUSOMAT 1250 A NFC and DIN - FUSOMAT 800 to 1250 A Direct front 16 External front A 330 F M fusom_048_g_1_x_cat J E min Top terminal screens 2. Reset Padlocking Front terminal screens Overall dimensions Switch body Switch mounting A 3p. A 4p. E min F 3p. F 4p. J 3p. J 4p. M 3p. M 4p. 800 (1) (1) NFC and DIN only. General Catalogue
11 Dimensions (continued) Side BS88 / NFC and DIN - FUSOMAT 250 to 630 A Direct side External side P A F M 90 V1 U W N AC AA BA K1 fusom_047_e_1_x_cat 2 V2 H Y Z T 1 R D shrouds. 2. Reset 70. Overall dimensions shrouds Switch body Switch mounting Connection A 3p. A 4p. D 3p. D 4p. AC F 3p. F 4p. H K1 M N P 3p. P 4p. R T U V1 V2 W 3p. 4p. Y Z AA BS88 / NFC and DIN - FUSOMAT 800 to 1250 A Direct side External side 16 M A F fusom_049_f_1_x_cat Top terminal screens 2. Reset Front terminal screens Ø D Overall dimensions Switch body Switch mounting A 3p. A 4p. D 3p. D 4p. F 3p. F 4p. M 3p. M 4p General Catalogue
12 Connection terminals FUSOMAT 800 A FUSOMAT 1250 A A connection terminals FUSOMAT 1250 A - Top FUSOMAT 1250 A A connection terminals FUSOMAT 1250 A - bottom A ø19x11 ø15 16 x x 11 fuser_317_a_1_x_cat fuser_318_a_1_x_cat fuser_319_a_1_x_cat Dimensions for external s FUSOMAT 250 to 1250 A Handle type Direction of Front Door drilling Direction of Side Door drilling fusom_073_a_1_gb_cat S3 type Ø3.07 Ø RESET 0 90 I Ø Ø I 4 Ø Ø General Catalogue
FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are
More informationFUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A
Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually
More informationSIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function
The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole
More information125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request
125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for
More informationSIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC
and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar
More informationSIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.
Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity
More informationSIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A
The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.
More informationWhat you need to know. Â Conformity to standards
SIRCO PV Load break switches for solar applications sirco_343_a_1_cat  What you need to know A solar electrical installation is an application that requires switching devices fully meet the needs of operational
More informationSIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points
Transfer switches svr_151_a The solution for > Manufacturing industry > Power distribution SRCOVER 2 Strong points > complete range > Easy connections > Stable positions svr_125_a_1_cat Bypass TS 0 Conformity
More informationSIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A
Load break switches new SRCO-pv_023_a_1_cat The solution for > Residential buildings. > Buildings. > Solar parks. Strong points Function SRCO PV are manually operated multipolar load break switches. They
More informationSIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability
More informationVistop TM isolating switches 63 to 160A
DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary
More informationATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions
to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination
More informationSIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A
Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented
More informationSIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC
Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar
More informationSIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC
SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar
More informationAn innovative technology
The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,
More informationsirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed
site_317_a sirco-ul_22_b_cat sirco-ul_4_b_cat 1A to 2A - 6VDC and 1VDC UL98B Listed  Function non fusible disconnects are heavy duty switches that break and make 6VDC or 1VDC photovoltaic circuits on
More informationSIRCO M and MV Universal load break switches from 16 to 160 A
SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV
More informationATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A
Transfer switches Accessories Terminal shrouds IPX protection against direct contact with terminals or connecting parts. Advantages Perforations allow remote thermographic inspection without the need to
More informationLoad break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...
Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch
More informationCATALOGUE MARINE APPLICATIONS. Energy performance solutions
CATALOGUE MARINE APPLICATIONS Energy performance solutions 2017 2018 Marine Certifications Our certified products As an independent manufacturer, we, at Socomec are committed to adapting the range and
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A
ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat
More informationNon-fusable disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages
More informationSIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC
Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More informationSIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong
More informationSIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC
Load break switches sircopv_058_a cat SIRCO PV UL98 new sircopv_059_a cat The solution for > Combiner box > Recombiner box > Inverter Function SIRCO PV UL98 non fusible disconnect switches are heavy duty
More informationATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A
TyS t M - TyS g M utomatic Transfer Switching Equipment Transfer switches new The solution for > High Rise uildings > Data centre > Healthcare buildings TyS g M I-0-II P atys-mg_001_b_1_cat Function TyS
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationDPX Magnetic only
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY
More informationMOULDED CASE CIRCUIT BREAKERS BC160N
D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage
More informationTHE SANTON FCS-TYPE SWITCH DISCONNECT. Superior Switch Solutions
THE SANTON FCS-TYPE SWITCH DISCONNECT Superior Switch Solutions The technical information given in this table applies to and pole fuse combination switches. A B NOMINAL RATING 0A A FUSE COMBINATION SWITCHES
More informationPowerLine OS Switch Fuses A, 690V
Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected
More informationMotorised and automatic transfer enclosed switchess
s Integrated products and solutions coff_538_a.eps atysm_251_b_1_cat.eps The solution for > igh-rise buildings > Data centers > Energy generation > ealthcare buildings > Banks and insurance companies >
More informationCOMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33
BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting
More informationSWITCH FUSES 3KL71 from 32A to 800A Description
from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationOvercurrent releases - description, specifications, characteristics specifications specifications description...
BA5*37 COMMERCIAL INFORMATION Type designation specification for ordering...68 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting
More informationWall mounted switchgear
Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page
More informationSwitching, control and protection solutions for solar applications
Switching, control and protection solutions for solar applications continuous performance www.socomec.com Summary SIRCO M PV Manually operated modulable and modular switches p. 4 SIRCO MV PV Manually
More informationSafety enclosures Normal atmospheres steel enclosure from 50 to 1600 A
Integrated products & solutions The solution for > Iron and steel industry > Cement plants > Paper mills > Sawmills > Hydraulic power packs > Automotive > Mining coff_436_a coff_434_a Strong points Function
More informationSIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200A
2017 CTLOGUE extract SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200 Transfer switches svr_207_a.eps svr_208_a.eps The solution for > Manufacturing > Power
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationmax pole for t=15 ms
Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole
More informationFuse switch-disconnectors
Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions
More informationDPX 630 Thermal magnetic and trip-free switches DPX-I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationvertical fuse switch disconnectors
SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -
More informationDPX Electronic + earth leakage
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL
More informationMANUALLY OPERATED CHANGEOVER SWITCHES
are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application: NORMA/EMERGENCY Application: UPS,
More informationFuse switch disconnectors
SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationSIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A
Conformity to standards (1) Changeover switches svr-ul_14_b_1_cat > EC 6947-3 > UL98, Guide WHTY, file 1138 > UL18, Guide WPYV, file 31792 > CSA 22.2#4, Class 4651-2 (1) Product reference on request. svr_136_a_2_cat
More informationDPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationIP20 degree of protection; IP40 degree of protection after installation in a distribution box
RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance
More informationPractical and completely safe
FUSE RRIERS >>> Practical and completely safe Isolating fuse carriers 058 06 058 28 Dimensions (p. 0) onform to standard IE 60269-2/2. and to NF 63-2. Isolators conform to IE 60947-3. Icc: - 20 k with
More informationDPX 630 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationDPX 160 Thermal magnetic and trip-free switches DPX-I 160
87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationMS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories
Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10
More informationSwitch disconnectors
Selection Load break switch disconnectors type LK3, 40-120 A Selection guide for 3 and 4-pole switch disconnectors General The LK3 range of switch disconnectors (lth: 40 A to 120 A) is designed for use
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationSafety enclosures. 482 General Catalogue SOCOMEC. Safety enclosures
coff_163_a_1_cat coff_156_b_1_cat Function equipped with SOCOMEC switches provide emergency breaking, breaking for mechanical maintenance and safety isolation in the vicinity of any low voltage final circuit.
More informationTAE pole Contactors
TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges
More informationDPX 1600 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationFuse switch-disconnectors
Fuse switch-disconnector FH00 is intended fuse-links with blade contacts size 000 and 00. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More informationTeSys GS & DF Fuse protection
TeSys GS & DF Fuse protection Simple and effective protection TeSys GS Fuse disconnect switches Total isolation between poles Safe replacement of the fuses (double breaking system) Frontal and right side
More informationMiniature Circuit Breaker
Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the
More informationTransfer switching solutions
CATALOGUE EXTRACT Transfer switching solutions from 40 to 6300 A 2018 Contents The SOCOMEC Group... Security and reliability for your transfer applications... Remotely operated and Automatic Transfer
More informationNEW TX³ RANGE PROTECTION YOU CAN RELY ON
TX³ NEW RANGE TRUSTED PROTECTION FOR YOUR INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW TX³ RANGE PROTECTION YOU CAN RELY ON Designed to meet the requirements of
More informationVarius SUMMARY OF MODELS
SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00 2 4a Fuse-link
More informationAF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals
AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.
More informationRESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE
OLE Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE OLE-10B-1N-030AC The device is a combination of residual current circuit breaker and circuit breaker.
More informationProtection and Connection Motorized and automatic transfer switches IEC Technical guide
Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationProtection components
Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationFuse switch disconnectors
SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED
More information01 Spectra Plus - Introduction
01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from
More informationPANEL PANEL MOUNTING COMPONENTS
PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology
More informationDX³ RCCBs - ID 4P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationSENTRON Switching and Protection Devices Switch Disconnectors
SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationMS General Information Extended Product Type: MS
MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual
More informationRX 3 MCB 4500 A Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More information