PowerLine OS Switch Fuses A, 690V
|
|
- Annabella Pitts
- 6 years ago
- Views:
Transcription
1 Technical Brochure PowerLine OS Switch Fuses A, 690V Brochure OS 10 GB CD04 ABB Control
2 New Switch Fuse Range 2 3
3 Total user safety Total user safety Fuse carriers fully IP20 protected The fuse covers cannot be opened while the switch fuse is in the ON position Patented, operator-independent quick make/quick break mechanism Fuse links are isolated on both sides of the fuse Fully-protected construction, IP 20, in types OS for both cable terminals and fuses, optional IP20 terminal shrouds in OS 160 types Various types for world-wide applications: Suitable fuses: DIN, size : A, BS88, E1, F1, A1-A4: A NFC (French): A UL (U.S.A.) and CSA (Canada), Class J: A CSA, class CC - C: A Flexible mounting options Mounting on the 35 mm or 75 mm DIN rail or with screws to the mounting plate Symmetrical construction, enabling an upside-down mounting A mounting screw hole template is printed on the box Compact and costsaving Auxiliary contacts with simple snap-on mounting All blocks IP20 protected Test Function- Easy and quick commissioning Auxiliary contacts_ Unique patented design for the 21st century The new OS switch fuses offer an economical and reliable solution for fused short-circuit protection. 4 5
4 Fuse monitor Handles OFM fuse monitor - facility for immediate tripping under blown fuse conditions No danger for 2-phase motor loading, prevents unsafe neutral voltages Operates with all standard fuses; striker-type fuses are not required, thus reducing overall costs No need for external supply voltage Wide voltage ranges, VAC and VAC, +/ - 10 % Safe and reliable EMC tested Fuse Monitor is automatically reset after the blown fuses have been replaced. One trip contact, one alarm contact, and LEDs (red and green) Full operational ability even with phase imbalance Compact size Snap-on mounting for OS switch fuses Mechanical blown fuse indicator for striker type fuses External front or side operated IP65 handle with an adjustable shaft. Handles available in three colours: black, yellow/red and grey Optional switch-mounted handle (mounting behind the door), also enabling the use of switches padlocked in the OFF position together with an external handle Defeatable door interlocking, even with IP 65 protection class The door cannot be opened if the switch is padlocked in the OFF position The handle can be padlocked in the OFF position with three padlocks, thus preventing the door from opening, and closing the circuit during maintenance The handle cannot be padlocked in the OFF position if any of the contacts are not totally open 6 7
5 Side operated Easy to adapt for different applications Flexible mounting From 1 pole to 4 pole front and side operated switch fuses. With conversion kits up to 6 and 8 pole switches. Change-over, mechanically interlocked switch combinations can also be built using optional mounting kits Side-to side, plug-in and back termination available Technical features suitable for extreme conditions: Short circuit current up to 100 ka/500 V Utilisation category: AC23 up to 690 VAC Rated impulse withstand voltage: 12 kv Extra thick, 20 mm silver coating on all conductive parts as standard. The silver coating extends the life of the switch fuse, especially in hazardous environments such as the pulp & paper industry 8 9
6 Switch fuse type OS Mini OS OS Current ratings 20A 25A 30A 32A 35A 30A 32A 50A 60A 63A 100A 125A 160A Front operated, 3 and 4- pole Mechanism between the poles Mechanism at the end of the switch Side operated, 3 and 4- pole Fuse types: Fuse standards DIN 43620, IEC SEC I DIN 000, 00 DIN Neozed (available year 2000) Fuse standards BS 88-2, -6, IEC SEC II, -IV BS A1 BS F1 BS A2 BS A3 BS A4 Fuse standards NFC 63210, NFC 63211, IEC SEC III NFC, 10x38 NFC, 14x51 NFC, 22x58 Fuse standards UL 198C, IEC SEC V UL, J UL, CC Fuse standards CSA C22.2 No 106, IEC SEC II (Dim.) CSA, C Technical data Rated operational current, AC-23A Up to 500 V A V A * 63* 100* 125* 160* * AC-23B Rated operational power, AC V kw V kw V 500 V kw kw V kw Weight, 3-pole kg
7 The technical data and dimensions are valid at the time of printing. We reserve the right to subsequent alternations. ABB Control Oy P.O. Box 622 FIN VAASA Finland Tel Fax
Technical Brochure. Switch Fuses DIN and NFC-Standard. Selection Table. Brochure OESA 2DIN GB Mallipohja. Low Voltage Products
Technical Brochure Switch Fuses DN and NFC-Standard Selection Table Brochure ESA 2DN GB 99-12 Mallipohja Powerline S switch fuses 20...160A, 690 V Unique patented design for the 21st century Total user
More informationLow Voltage Products. ABB Building Technologies. PowerLine OS and OESA Switch Fuses. Brochure OS-OESA 1 GB 00-05
Low Voltage Products PowerLine S and ESA Switch Fuses Brochure S-ESA 1 GB 00-05 ABB Building Technologies < < Fuse Protection - Easy and Reliable Complete range of switch fuses 20A to 800A, 690V S 20...200
More informationFUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A
Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong
More informationNon-fusable disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages
More informationFUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationTechnical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products
94 D 5384 Technical Brochure Rotary Type nstallation Switches 16...160 A, 500 V Brochure T_M 22 GB 99-08 Low Voltage Products 9809CD03 Rotary Type nstallation Switches 16 A...160 A ew features for installation
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually
More informationSIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A
The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.
More informationContact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE
Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are
More informationSIRCO M and MV Universal load break switches from 16 to 160 A
SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV
More informationSIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong
More informationCATALOG. EasyLine XLP Fuse Switch Disconnector poles
CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction
More informationSuitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators
SafeLine Compact, heavy duty disconnect 6A 200A 30A 200A Fusible Disconnect SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings
More informationSIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A
Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented
More informationAn innovative technology
The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,
More informationFUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems
FUSERBLOC CD The universal Fuse Combination Switch FROM 20 TO 1250 A SOCOMEC GROUP SWITCHING PROTECTION & UPS Industrial Switching & Protection Systems SWITCHING FUSERBLOC CD THE UNIVERSAL FUSE COMBINATION
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More informationSuitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators
SafeLine Compact, heavy duty disconnect 16A 00A 30A 00A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational
More information34OSM_ rev. C / 1SCC311029M0203. Motorized switch fuses OSM_ Installation and operating instructions
3OS_ rev. C / SCC309003 otorized switch fuses OS_ Installation and operating instructions Contents Installation and operating instructions, OS_ Contents. Introduction.... Use of symbols.... Explanations
More informationSwitch Disconnectors
Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles
More informationLOAD BREAK SWITCHES. Ensto Compact
LOAD BREAK SWITCHES Ensto Compact Ensto Enclosures and Components Ensto also offers enclosed switches; being assemblies of Ensto Cubo enclosures and load break switches. Ensto is an international industrial
More informationUL 508 Non-Fusible Disconnect Switches
UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.
More informationLoad break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...
Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch
More information25A 25A 32A 40A 40A 63A 63A 80A
ISDC Compact Range 25A - 200A Control Panel Isolation Equipment Craig & Derricott has ranges of Switch-Disconnectors, Fuse Combination Units and Changeover Isolators for panel mounting ranging from 25A
More informationSWITCH DISCONNECTORS PLANET -SWITCH.
SWITCH DISCONNECTORS 6A to 600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 50A. PLANET -SWITCH SEC. PAGE
More informationUL 508 Non-Fusible Disconnect Switches
UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.
More informationFUSIBLE DISCONNECT SWITCHES
FUSIBLE DISCONNECT SWITCHES HIGHLIGHTS: Double break contacts per pole up to 400 A Touch safe fuse covers/line shrouding standard Service Entrance Rated Compact Footprints Front operated switches Side
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationEnclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes
Protection and Connection Enclosed DC rated switchdisconnectors OTDCP from 16 to 32 Amperes Enclosed OTDC switches from 16 to 32 Amperes meet the demanding requirements of photovoltaic applications. Enclosed
More informationSWITCH FUSES 3KL71 from 32A to 800A Description
from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used
More informationMini contactors B6, BC6 with 3 pole
Data sheet Mini contactors B6, BC6 with 3 pole Mini contactors from ABB are used for remotely ling motors and other loads wherever space is at a premium. These devices feature hum free coils, shallow depth,
More informationIEC Low Voltage Products Module 4
IEC Low Voltage Products Module 4 IEC Low Voltage Products NH DIN o All variations o Features benefits o Dual indication IEC Cylindrical Fuse System o Wide range of sizes and ratings o CCP NEW Product!
More informationSAFETY SWITCHES / ISOLATORS A TECHNICAL DATA
ENCLOSED SWITCHES SAFETY SWITCHES / ISOLATORS 16-800A TECHNICAL DATA Safety switches / isolators 10A 16A 25A 40A 63A 80A 125A 160A 200A 250A 315A 400A 630A 800A Rated Insulation voltage Ui (V) 690 690
More informationLOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA
LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES Complying with BSEN60947 and IEC 408 the RDMP range of rotary cam switches are suitable for on load switching of general distribution
More informationProduct brochure. ABB Fusegear EasyLine Fuse switch disconnector
Product brochure ABB Fusegear EasyLine Fuse switch disconnector 2 EasyLine Fuse Switch Disconnector ABB Fusegear Content Fuse protection 4 Technical Data 5 General 6 Apparatus overview 7 Electronic Fuse
More informationSIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More informationUL/CSA Non-fused Disconnect Switches
Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1
MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More information125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request
125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for
More informationNon-Fused Load Break Switches FSSC, SX, SXDC, SC
Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty
More informationMotorized switch-disconnectors OTM 40 to 125 Amperes
Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution
More informationSwitches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference
Load Break Switches According to BS EN60947-3 High Thermal & Dynamic Strength Fully rated suitable for distribution & motor loads Auxiliary contacts also available Fully Visible Breaking Arduous categories
More informationEmergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0
MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationLow Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201
Low Voltage Products SwitchLine OT change-over switches 160, 200, 0, 315, 400, 630 and 800 mps Catalogue OT7G 05_09 1SCC301012C0201 Ith / Ie /C22, 415V Ie /C23, 415V OT160E OT160E_W OT200E OT200E_W OT0E
More informationLow Voltage Switches. Fusegear Switch fuses OS and OSM
Low Voltage Switches Fusegear Switch fuses OS and OSM Switch fuses OS 16...1250, OSM 32...1250 Contents 4 Product overview 6 Features 8 Technical data 18 Ordering information, manual operation 18 DIN-
More informationSuitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators
SafeLine Compact, heavy duty disconnect 16A 3150A 30A 3000A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational
More informationSIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A
Load break switches new SRCO-pv_023_a_1_cat The solution for > Residential buildings. > Buildings. > Solar parks. Strong points Function SRCO PV are manually operated multipolar load break switches. They
More informationUltraSafe US22 Modular fuse-holders
UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards
More informationSwitches for photovoltaic applications Switch-disconnectors OTDC and OTDCP
Contact us ABB Oy Breakers and Switches P.O. Box 622 FI-65101 Vaasa, Finland Phone: +358 10 22 11 Fax: +358 10 22 45708 E-Mail: firstname.surname@fi.abb.com www.abb.com The technical data and dimensions
More informationSwitch fuses OS , OSM
Switch fuses OS 16...1250, OSM 32...1250 Contents 4 Product overview 6 Features 8 Technical data 16 Ordering information, manual operation 16 Front operated switch fuses OS 25 Side operated switch fuses
More informationL O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR
L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR The safest way to switch power on and off in your industrial control panels. Your problem: You
More informationMiniature Circuit Breaker
Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More informationSemiconductor (AC) fuses
Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN
More informationPowerLine Switch Fuses OESA_PL, A. Contents: Technical data... 9/2. Ordering information DIN-pattern... 9/3 BS-pattern...
Switch Fuses ESA_PL, A Contents: Technical data... /2 rdering information DN-pattern... /3 BS-pattern... /3 Accessories... /4 Dimension Drawings... /6 /1 Technical Data Switch Fuses ESA Technical Data
More informationLow Voltage Apparatus. Technical Brochure. BaseLine. Fuse Bases OFAX, OFAS_ 690 V. Brochure OFA 1A GB 91-02/ 95-11/97-03.
Technical Brochure Low Voltage Apparatus BaseLine Fuse Bases OFAX, OFAS_ 690 V Brochure OFA 1A GB 91-02/ 95-11/97-03 ABB Control Oy S00279A Fuse Bases OFAX 00, 1, 2 and OFAS_3 Standards: IEC 269-2-1 IN
More informationPage 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.
Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated
More informationnew NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price
NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high
More informationVistop TM isolating switches 63 to 160A
DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary
More informationPhelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES
DESIGN FEATURES Double break contacts Polycarbonate shroud for wired terminal protection included Excellent switching & high short circuit capacity Compact and reliable Easy installation Front, rear and
More informationNon-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.
disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance
More informationLow Voltage Products. Enclosed switches. Brochure OT_KSE 1 GB 05_02 1SCC340007C0201
Low Voltage Products Enclosed switches Brochure OT_KSE 1 GB 05_02 O I N O SafeLine OF F 2 I Enclosed switches Contents: General... 4 Technical data... 5 Switches in plastic enclosure General... 6 Ordering
More informationLow Voltage Products. Switches Switch-disconnectors OT and OETL
Low Voltage Products Switches Switch-disconnectors OT and OETL Switch-disconnector IEC lth /A le /AC22A, 415V le /AC23A, 415V... OT16F OT63F OT100F OT160E OT25F OT80F OT125F OT40F 25 32 40 63 80 115 125
More informationWall mounted switchgear
Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationTeSys GS & DF Fuse protection
TeSys GS & DF Fuse protection Simple and effective protection TeSys GS Fuse disconnect switches Total isolation between poles Safe replacement of the fuses (double breaking system) Frontal and right side
More informationBreakers and Switches. Switches Change-over and transfer switches
Breakers and Switches Switches Change-over and transfer switches Change-over and transfer switches 16...2500 A Contents: 4 Product overview, features 8 Technical data 8 Manual, motorized and automatic
More informationLow Voltage Switches. Switches Motorized change-over switches OTM _C
Low Voltage Switches Switches Motorized change-over switches OTM...12_C II I OTM 12_C Improves your permance OTM II I 0 OFF ON I 0 OFF II I ON I ssembly made easy Bridging bars quick wiring Tunnel terminals
More informationModulostar US10 Modular fuse-holders
Modulostar US10 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC standards
More informationFusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web: -
disconnect A 1200A, 600VAC Disconnect Disconnect ABB PowerLine includes seven different amperage sizes from A to 1200A. All ABB fusible are designed to meet customer requirements in terms of high interrupting
More informationFUSE BASES NH FUSE BASES 690V 160A 160A
fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or
More informationProtection and Connection Motorized and automatic transfer switches IEC Technical guide
Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety
More informationSwitches disconnectors with fuse-holders. XNF series TF series
Switches disconnectors with fuse-holders XNF series TF series Quick Reference Switch-disconnectors with fuse-holders XNF series TF series XNF Series page 155 16 32A with fuse holders 3 4 Pole Auxiliary
More informationRotary Disconnect Switches, Bulletin 194R
ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION Rotary Disconnect Switches Bulletin 194R NOTICE: The specification guidelines in this document are intended to aid in the specification
More informationThermal Overload Relays
Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They
More informationLow Voltage Switches. Switches Switch fuses OS A Gamma series
Low Voltage Switches Switches Switch fuses OS32...1 Gaa series Switch fuses for extreme conditions - OS 32 1 Gaa series Numerous applications require switch fuses that can withstand extreme conditions.
More informationSwitches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes
Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes OTDC16...32U - Compact efficiency OTDC from 16 to 32 amperes offers various DC voltage ratings and a control
More informationNon-Fused Load Break Switches FSSC, SX, SXDC, SC
UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most up-todate disconnect
More informationWhat you need to know. Â Conformity to standards
SIRCO PV Load break switches for solar applications sirco_343_a_1_cat  What you need to know A solar electrical installation is an application that requires switching devices fully meet the needs of operational
More informationVB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated
VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control
More informationManual Motor Starter MS 116. Technical Catalogue
Manual Motor Starter MS 116 Technical Catalogue The task: Economic fuseless motor protection Know-how in safe-keeping ABB is a renowned manufacturer of electrical motors. But apart from the hardware in
More informationMiniature Circuit Breakers
S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions
More informationMain switches in accordance with European standard directives
Main switches in accordance with European standard directives N N ABB y ABB Switches in accordance with EU Directives New concept n order to dismantle technical barriers in commerce, the Council of the
More informationATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A
ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat
More informationDescriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications
Descriptive bulletin Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications General overview Reliable, low maintenance and economical Load Interrupter
More informationFuse holders and fuses
Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator
More informationBreakers and Switches. Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP
Breakers and Switches Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP Switch-disconnectors OTDC16...250, OT315...630 and OTDCP16...32 Contents 4 Product overview 8 Technical data
More informationGeneral information about motor protection
Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch
More informationPROTECTION AND CONNECTION. ABB Compact ATS Compact without compromise
PROTECTION AND CONNECTION ABB Compact ATS Compact without compromise 2 A B B C O M PA C T AT S C O M PA C T W I T H O U T C O M P R O M I S E ABB ARTICLE COMPACT OR CHAPTER ATS COMPACT TITLE WITHOUT COMPROMISE
More informationIP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description.
General Description Supplied in hinged lid grey powder coated sheet steel enclosures, these IP41 sealed assemblies are eminently suitable for most indoor industrial applications. Supplied as Switch-Disconnectors
More informationLoad Break Disconnect Switches FSLBS
Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable
More informationLow Voltage Switches. Switches and fusegear Motorized switch-disconnectors OTM and switch fuses OSM
Low Voltage Switches Switches and fusegear Motorized switch-disconnectors OTM and switch fuses OSM Motorized switches OTM 60...2500, OSM 2...250 Contents Product overview 6 Features 8 Technical data 6
More informationApprovals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking
MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationModulostar CMS10 Modular fuse-holders
Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC
More informationCat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
More information