01 Spectra Plus - Introduction

Size: px
Start display at page:

Download "01 Spectra Plus - Introduction"

Transcription

1

2 01 Spectra Plus - Introduction Standard features Conforming to IS /EN Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from 50% to 100% Current limiting Choice of rating plugs Variable short circuit and overload settings Suitable for isolation No line-load biasing Double forward facing insulation Trip free mechanism Positive ON/OFF indication flags Common field mountable internal accessories General characteristics Description Spectra Plus moulded case circuit breakers with microprocessor protection, are available in three and four pole versions. The Spectra Plus circuit breakers have individual rating plugs and enable protected distribution of electricity within a current range of 20A and 630A.

3 Spectra Plus - Introduction 02 Current limiting 1 The limiting capacity of a circuit breaker is the expression of the breaker s capacity. In the event of a short circuit, it reduces the let through current to a lower value than the prospective fault current. This characteristic is expressed by the following limiting curves: 1. Icc unlimited peak 2. Icc limited peak (actual) 2 The great limiting capacity of Spectra Plus circuit breaker is a result of the optimal combination of: A light moving part, reducing inertia. A strong current loop, to generate maximum force of repulsion. A slot motor with strong electro-magnetic field to accelerate the opening of the contact. Contact materials combining good conductivity and high durability. An arc chamber combining a high energy absorption capacity, speed in breaking of arc and cooling of gases. This combination has enabled an exceptional breaking capacity/volume ratio. The use of Spectra Plus circuit breaker enables a great reduction in stresses that normally develop during a short-circuit: Reduction in thermal constraints in conductors, increasing their life. Reduction in mechanical constraints due to the reduction of the electrodynamic forces of repulsion between conductors, which reduces the risk of deformation or rupture of the wiring. Reduction in electro-magnetic effects. The electro-magnetic field reduces and causes less damage to neighboring devices and sensors. Use Spectra Plus circuit breakers provide a solution for standard and high performance levels upto 50kA breaking capacity in 3 frames SE160, SF250 & SG400/630. Suitability for visible isolation Spectra Plus circuit breakers are ideal for fully visible isolation selection. With the handle free, the indication open (green display) is only possible when the main contacts are separated by a distance of >20mm. Spectra Plus circuit breaker conforms to standards: IEC947-3, IS recommended for isolation. Double forward facing insulation Spectra Plus circuit breakers are provided with forward facing spaces designed for insertion of internal electrical auxiliaries. These spaces are completely insulated from the power circuit. Accreditation / Certification IEC947-2, EN , IS13947, Lloyd s Register of Shipping, RINA.

4 03 Spectra Plus - Introduction High performance electronic protection The current sensor output signal for each phase is sampled more than 30 times per cycle in order to establish the true RMS value, independent of the network, the nature of the load and the environment of the installation. Hence, Spectra Plus guarantees correct protection. Power source The power source can be connected either from upline or downline of the Spectra Plus circuit breaker, and up to the maximum voltage for use (690V). Orientation A fixed circuit breaker can be mounted as follows:

5 Spectra Plus - Introduction 04 Electrical auxiliaries BA bell alarms, AS auxiliary ON/OFF switches, ST voltmetric shunt releases and UV undervoltage releases are common to all Spectra circuit breakers. e.g. an AS auxiliary ON/OFF switch can be installed equally well on an SE 160 or SG 630 circuit breaker. Thus it is not necessary to specify the type of circuit breaker. Only the release voltage and the type of contact (standard or low level) has to be indicated with the order. Assembly As this is intended for installation in compartments that are accesssible from the front, it is not necessary to take off the cover of the circuit breaker. Left-hand compartment Option of connecting UV or ST releases plus 3 pole BA. 1 or 2 additional AS contacts can be connected to 4 pole SG400 to SG630 circuit breaker (an extra socket is provided for this). On each circuit breaker, ducts for the wiring are provided enabling the passage of the cables to the right, left, or to the rear side of the device, without increasing its original dimensions. Right-hand compartment Option of connecting 1 or 2 AS auxiliary switches. On each circuit breaker, ducts for the wiring are provided enabling the passage of the cables to the right, left, or to the rear side of the device, without increasing its original dimensions. Maximum possibilities for auxilliaries Circuit Breaker 3P 4P AS 2 2 BA 1 1 ST or UV 1 1

6 05 Spectra Plus - Accessories Electrical auxiliaries AS auxiliary ON/OFF switches. Description Indicates the "open" or "closed" position of the circuit breaker to other auxiliaries such as logic circuits, relays, displays, etc.. for control, locking, or remote indicator functions. Characteristics open close open close Changeover contacts get activated at the same time as main poles. 2 versions: changeover C/O or 2 changeover C/O (in the same volume). 12 Standard contacts Operating voltage (V) AC Hz DC 120 to to 125 Load - resistive inductive Uninterrupted current (A) Breaking capacity (A) Closing capacity (A) common Wiring colour code 12: BNWH (brown & white) 14: RD (red) 11: WH (white) 22: OGWH (orange-white) 24: OG (orange) 21: GY (grey) common BA bell alarm contacts Description Changeover contacts signalling the "tripped" status of the circuit breaker caused by a fault or opening by voltmetric ST or UV trip devices, or by an earth leakage device. The contact returns to the "normal" position on resetting of the circuit breaker. The BA contact is not activated with a normal closing or opening of the circuit breaker. Characteristics Standard contacts Operating voltage (V) AC Hz DC 120 to to 125 Load - resistive inductive Uninterrupted current (A) Breaking capacity (A) Closing capacity (A) normal default common Wiring colour code 96: GN (green) 98: BN (brown) 95: YE (yellow) Earth fault module Description EFM250* Earth fault module is a compact and microprocessor based solution used with the Spectra Plus range for providing effective Earth fault protection. - Range 5% to 80% of In (In settable) - Delay 50msec to 5 sec. - Suitable for 3Phase 3Wire and 3Phase 4Wire system up to 630A * For 400/630A please contact our nearest office.

7 Spectra Plus - Accessories 06 Shunt release ST Description Shunt release ST causes the remote opening of the circuit breaker as soon as it receives power (power can be permanent). Operation is guaranteed from 55% of Un with alternating current and from 70% of Un with direct current. Characteristics Standard contacts Operating voltage (V) AC Hz AC * 55% of Un for AC - 70% of Un for DC DC Hz / / /415 Max. ringing current (ma) Average current (ma) Release breaking time (ms) min. (100% Un) max.* Wiring colour code: C1 - C2: Black(BK) Undervoltage release UV Description Undervoltage release UV causes opening of the circuit breaker in the event of a drop in voltage (35% to 70% of Un) guaranteed closure of the circuit breaker if Un > 85%. Operating range: 0.85 < Uc < 1.1 Un. When the release does not receive power, or voltage is too low, the circuit breaker cannot be reclosed; the contacts do not touch. Characteristics Standard contacts Operating voltage (V) AC Hz/DC / /250 (2) Max. calling current (ma) Average current (ma) Release breaking time (ms) mini (100% Un) maxi (1) Wiring colour code D1 - D2: Blue (BL) (1) 55% of Un for AC - 70% of Un for DC. (2) Time release MVR retarder (250, 500, 800, 1000 ms.) at 220V AC 50Hz. Avoids untimely tripping with sudden loss of voltage.

8 07 Spectra Plus - Data sheet Extended rotary handle Extended rotary handle ensuring a smooth operation of MCCB. The new extended handle has three distinct positions - ON, OFF & TRIP with padlock facility. Seperators / Spreaders Spectra Plus range has been designed for ease of proper termination with help of spreaders. Seperators are an integral part of MCCB and they help to enhance the insulation level between live terminals. Technical specifications Circuit Breakers SG 160 SG 250 SG 400 SG 630 S N S N S N S N Rated current lth (A) at 40 0 C Rated operating voltage Ue AC 50/60Hz (V) Rated insulation voltage Ui (V) Ultimate short-circuit breaking capacity lcu 50/60Hz 380/415V (ka) Service short-circuit breaking capacity lcs AC 50*60 Hz 380/415V (ka) Rated short-circuit making capacity lcm Ac 50/60 Hz 380/415V (ka) Rated impulse voltage Uimp (kv) Operational category A A A A A A A A Number of poles Endurance Mechanical operations Electrical operations Total fault elimination time (ms) <8 <8 <8 <8 <8 <8 <10 <10 Degree of pollution Rating Plugs 3Pole / 4Pole (Setting: %) Current Rating 32A 32A 125A 125A 250A 250A 400A 400A 63A 63A 250A 250A 400A 400A 630A 630A 100A 100A 160A 160A

9 Spectra Plus - Dimensions 08 Spectra Plus SE 160 Frame 3P Spectra Plus SF 250 Frame 4P 3P 4P Spectra Plus SG 400/630 Frame 3P 4P

10 09 Spectra Plus - Dimensions Door Drive Details - E Frame Door Drive Details - F Frame

11 Spectra Plus - Dimensions 10 Door Drive Details - G Frame Door Drilling Details for Mounting Handle on Panel Door

12

13 GE introduces Spectra TME125, a thermal magnetic MCCB in 3 / 4 pole for overload and short circuit protection. Spectra TME125 has been tested for breaking capacities upto 25kA at 415VAC. This MCCB provides protection for transformers, distribution circuits, cables and other equipment. Spectra TME125 Features Magnetic instantaneous trip actuates the trip mechanism without any delay in the event of short circuit Current limiting, quick make, quick break mechanism that operates independent of manual force Positive trip indication knob comes to a distinct position when the breaker trips due to overcurrent or short circuit faults Effective arc runner pushes the arc in the arc chute thereby reducing the contact tip damage and increasing the contact s life Red colour PUSH TO TRIP button is provided to check the tripping mechanism Contacts are made of silver alloy with an anti-welding property Internal and external accessories that can be fitted on site Variable thermal setting from % Trip free mechanism Thermal memory

14 Technical Particulars Rated Currents (In) 16A, 20A, 32A, 40A,50A, 63A, 80A, 100A, 125A 16A, 20A, 32A, 40A, 50A, 63A, 80A, 100A, 125A Rated Operational Voltage Rated Insulation Voltage Rated Frequency 415VAC 690VAC 50Hz 415VAC 690VAC 50Hz No. of Poles 3 / 4 Pole 3 / 4 Pole Utilization Category A A Rated Ultimate Short Circuit Breaking Capacity Rated Service Short Circuit Breaking Capacity Overload Adjustability 18kA 25kA 50% 40% % % Reference Standard Termination IS & IEC sqmm Cu cable, or 16 X 6mm links IS & IEC sqmm Cu cable, or 16 X 6mm links ±0.2 35±0.2 35± ± ±0.2 35±0.2 35± ±0.2 NEUTRAL 152± ± PUSH TO TRIP PUSH TO TRIP GE India Industrial Pvt. Ltd. The Millenia, Level 6, Tower B, #1 & 2, Murphy Road, Ulsoor, Bangalore Ph: (080) , Fax: (080) query@ge.com 0910/GR/SP

15 GE introduces Spectra TM200, a thermal magnetic MCCB in 3 / 4 pole for overload and short circuit protection. Spectra TM200 has been tested for breaking capacities upto 36kA at 415VAC. This MCCB provides protection for transformers, distribution circuits, cables and other equipment. Spectra TM200 Features Variable thermal setting from % Current limiting, quick make, quick break mechanism that operates independent of manual force Positive trip indication knob comes to a distinct position when the breaker trips due to over-current or short circuit faults Effective arc runner pushes the arc in the arc chute thereby reducing the contact tip damage and increasing the contact s life Contacts are made of silver alloy with an anti-welding property Magnetic instantaneous trip actuates the trip mechanism without any delay in the event of short circuit Red colour PUSH TO TRIP button is provided to check the tripping mechanism Internal and external accessories that can be fitted on site Trip free mechanism Thermal memory

16 Technical Particulars Rated Currents (In) 160A, 200A 160A, 200A Rated Operational Voltage Rated Insulation Voltage Rated Frequency 415VAC 690VAC 50Hz 415VAC 690VAC 50Hz No. of Poles Utilization Category Rated Ultimate Short Circuit Breaking Capacity Rated Service Short Circuit Breaking Capacity Overload Adjustability 3 / 4 Pole 3 / 4 Pole A A 25kA 36kA 100% 75% % % Reference Standard Termination IS & IEC sqmm Cu cable, or 20 X 6mm links IS & IEC sqmm Cu cable, or 20 X 6mm links 95 30±0.2 30±0.2 15±0.115± ±0.1 83±0.1 30±0.2 30±0.2 30±0.2 15±0.1 2-INSERT M ± ± ± Ø Ø DIMENSIONAL DETAILS 160A - 200A DIMENSIONAL DETAILS 160A - 200A 3 POLE 4 POLE GE India Industrial Pvt. Ltd. The Millenia, Level 6, Tower B, #1 & 2, Murphy Road, Ulsoor, Bangalore Ph: (080) , Fax: (080) query@ge.com 0910/GR/SP

17 GE introduces Spectra TM125, a thermal magnetic MCCB in 3 / 4 pole for overload and short circuit protection. Spectra TM125 has been tested for breaking capacities upto 36kA at 415VAC. This MCCB provides protection for transformers, distribution circuits, cables and other equipment. Spectra TM125 Features Variable thermal setting from % Current limiting, quick make, quick break mechanism that operates independent of manual force Positive trip indication knob comes to a distinct position when the breaker trips due to over current or short circuit faults Effective arc runner pushes the arc in the arc chute thereby reducing the contact tip damage and increasing the contact s life Contacts are made of silver alloy with an anti-welding property Magnetic instantaneous trip actuates the trip mechanism without any delay in the event of short circuit Red colour PUSH TO TRIP button is provided to check the tripping mechanism Internal and external accessories that can be fitted on site Thermal memory Trip free mechanism

18 Technical Particulars Rated Currents (In) 16A, 20A, 32A, 40A, 50A, 63A, 80A, 100A, 125A 16A, 20A, 32A, 40A, 50A, 63A, 80A, 100A, 125A Rated Operational Voltage Rated Insulation Voltage Rated Frequency 415VAC 690VAC 50Hz 415VAC 690VAC 50Hz No. of Poles 3 / 4 Pole 3 / 4 Pole Utilization Category A A Rated Ultimate Short Circuit Breaking Capacity Rated Service Short Circuit Breaking Capacity Overload Adjustability 25kA 36kA 100% 75% % % Reference Standard Termination IS & IEC sqmm Cu cable, or 20 X 6mm links IS & IEC sqmm Cu cable, or 20 X 6mm links 95 30±0.2 30±0.2 15±0.115± ±0.1 83±0.1 30±0.2 30±0.2 30±0.2 15±0.1 2-INSERT M ± ± ± Ø Ø DIMENSIONAL DETAILS 160A - 200A 3 POLE DIMENSIONAL DETAILS 16A - 125A 4 POLE GE India Industrial Pvt. Ltd. The Millenia, Level 6, Tower B, #1 & 2, Murphy Road, Ulsoor, Bangalore Ph: (080) , Fax: (080) query@ge.com 0910/GR/SP

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

Record SL. Moulded Case Circuit Breaker

Record SL. Moulded Case Circuit Breaker Record SL Moulded Case Circuit Breaker The new GE Record SL Moulded Case Circuit Breaker family is a line of reliable, simple and easy to use protection devices for use in both moderate or hot and humid

More information

B 1. SPECTRA - Moulded case circuit breakers. Contents. B.2 General characteristics. B.6 Technical data. B.8 Functions. B.10 Operating curves

B 1. SPECTRA - Moulded case circuit breakers. Contents. B.2 General characteristics. B.6 Technical data. B.8 Functions. B.10 Operating curves SPECTRA - Moulded case circuit breakers Contents.2 General characteristics.6 Technical data.8 Functions.10 Operating curves.11 Limiter circuit breakers 1.12 Earth leakage protection circuit breakers.13.14

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Spectronic SP Air Circuit Breaker. Protecting people, property & productivity

Spectronic SP Air Circuit Breaker. Protecting people, property & productivity Spectronic SP Air Circuit Breaker Protecting people, property & productivity Spectronic SP Air Circuit Breaker Circuit Breakers 800 to 2500A Series SP Rated short circuit breaking capacity : lcs 50 / 55KA

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Spectronic SP Air Circuit Breaker. Protecting people, property & productivity

Spectronic SP Air Circuit Breaker. Protecting people, property & productivity Protecting people, property & productivity Circuit Breakers 800 to 2500A Series SP Rated short circuit breaking capacity : lcs 50 / 55KA ( 415V) Complete range Fixed with manual control 3 or 4 Poles The

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

Thermal magnetic and trip-free switches

Thermal magnetic and trip-free switches 87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/

More information

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Overcurrent releases - description, specifications, characteristics specifications specifications description... BA5*37 COMMERCIAL INFORMATION Type designation specification for ordering...68 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times. The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.

More information

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144

More information

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33 BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

Motor Protection Circuit Breakers

Motor Protection Circuit Breakers Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

DRX 100 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

3VT Kompaktleistungsschalter bis 630A

3VT Kompaktleistungsschalter bis 630A Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Motor Protection Circuit Breaker

Motor Protection Circuit Breaker Motor Protection Circuit Breaker Catalogue 2011 CONTENT Introduction...4 Features...4 Parts Identification...5 Technical information (MPCB)...5 Technical information (Aux. contact, Fault signalling contact)...6

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

Motor Protection Circuit Breakers 3VU13 and 3VU16

Motor Protection Circuit Breakers 3VU13 and 3VU16 Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted 110 The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.

More information

New DX 3 High rating & breaking capacity

New DX 3 High rating & breaking capacity New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Terasaki (Europe) Ltd

Terasaki (Europe) Ltd Terasaki (Europe) Ltd Terasaki Europe Ltd was established in 97 and is located near Glasgow, Scotland U.K. From head office at our 7,00 square metre facility, Terasaki Europe controls an International

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

C60H-DC C curve. Catalogue numbers

C60H-DC C curve. Catalogue numbers distriution systems PB104013-34 The supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewale energy...). They comine the following functions

More information

Compact NR630. NR100F to NR630F

Compact NR630. NR100F to NR630F Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Breaking and protection devices

Breaking and protection devices Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply

More information

(Miniature Circuit Breaker)

(Miniature Circuit Breaker) (Miniature Circuit Breaker) Features : l Uniform 10KA breaking capacity for B and C Curve l Low power consumption, thus cost effective & energy saving l Suitable for DC and for a wide frequency range of

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

WORKSHOP SPECIFICATIONS

WORKSHOP SPECIFICATIONS WORKSHOP SPECIFICATIONS DPX 3 160 & 250 MOULDED CASE CIRCUIT BREAKERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DPX 3 RANGE Not only do DPX³ 160 and DPX 3 250 MCCBs provide

More information

RESIDUAL CURRENT CIRCUIT BREAKER

RESIDUAL CURRENT CIRCUIT BREAKER Quality Features Mid Trip - Different knob position to indicate whether the device is Switched OFF by a fault or Switched OFF manually Inscription Window - Ensures circuit identification and hence reduces

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

MCCB Accessories to suit AF

MCCB Accessories to suit AF MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager The RX 3 and DX-E ranges provide essential functions for the protection requirements of people and property in residential and small commercial buildings Two breaking capacities, 4500 and 6000 (IEC 60898-1)

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.

NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD. Shanghai Liangxin Electrical CO., LTD. - Liangxin Electrical - All rights reserved Address: No. 66 eng An Road, Pu Dong New District, Shanghai Post code: 07 Tel: 6--479 Fax: 6--5675966 E-mail: client@sh-liangxin.com

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

Electronic circuit breaker EBU10-T

Electronic circuit breaker EBU10-T Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions

More information

(p. 47) (p. 155) (p. 155)

(p. 47) (p. 155) (p. 155) 0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric. K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles

More information

Power protection solutions

Power protection solutions Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2 OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,

More information