Motor Protection Circuit Breaker

Size: px
Start display at page:

Download "Motor Protection Circuit Breaker"

Transcription

1 Motor Protection Circuit Breaker Catalogue 2011

2

3 CONTENT Introduction...4 Features...4 Parts Identification...5 Technical information (MPCB)...5 Technical information (Aux. contact, Fault signalling contact)...6 Technical information (Under voltage trip, Shunt trip)...6 Motor rating & current setting range...7 Dimension...7 Time current characteristics...8 Let through energy characteristics...8 Add on accessories...9 Circuit diagram...9 Ordering information (MPCB)...10 Ordering information (Add on accessories)...10

4 INTRODUCTION Havells presents the versatile MB2 series motor protection circuit breakers specifically designed for control and protection of motors, conforming to IS / IEC & IS / IEC standards. Motor Circuit Breakers are advanced three pole thermal-magnetic circuit breakers offering excellent short circuit protection by magnetic non adjustable tripping elements under 3ms, this results in rapid build up of an arc voltage which limits the current of the short circuit to a very low level. Infact, this current limiting capability of MB2 motor breakers provides high short circuit breaking capacity upto 100 ka. The thermal elements coupled with automatic ambient temperature compensation over a range of -20 C to +60 C provide close / accurate overload protection qualifying it as a trip class 10 device. The breaker comes with a wide range of add-on accessories to meet variety of application needs in motor circuits and system automation. Operation Motor Circuit Breakers control is manual and local when it is used on its own. However when it is used in conjunction with a contactor, the control is automatic and remote. The ON / OFF actuation is by push button. Switching ON is controlled manually by operating the start button marked I and switching OFF by operating the stop button marked O or automatically by the thermal magnetic protection elements or by a voltage trip add on accessory namely: Shunt trip / Under Voltage Trip (UVT). Protection Motor protection is provided by the thermal-magnetic protection elements incorporated in the motor circuit-breaker. The magnetic elements (short-circuit protection) have a non-adjustable tripping threshold, fixed at 13 times the maximum setting current of the thermal trips. The thermal elements (overload protection) include automatic compensation for ambient temperature variations. The rated operational current of the motor is displayed by means of a graduated / calibrated knob. All live parts are protected against direct finger contact from the front panel. Personal protection is also provided. The undervoltage trip allows the circuit-breaker to de-energize in the event of an undervoltage condition. The user is therefore protected against sudden starting of the machine when normal voltage is restored, since the Start button I has to be pressed to restart the motor. The shunt trip provides remote tripping of the circuit-breaker. These circuit breakers are suitable for isolation. The start button can be padlocked in stop position in open execution unit. Connection The MPCBs are designed for connection by screw clamp terminals. Mounting These motor circuit-breakers can be mounted by screw fixing or clip on mounting on symmetrical, asymmetrical or combination Din-rail. FEATURES HAVELLS MB2 series motor protection circuit breaker effectively combines control & protection lending greater efficiency & flexibility through various functions, accessories & compact design Compact size & space saving Close overload & short circuit protection High breaking capacity Sensitive to single phasing Visual fault indication Simple & easy installation Wide range of accessories Available in open execution / in plastic enclosure 4

5 PARTS IDENTIFICATION Finger safe terminals Front aux. contact Current setting dial Mounting on DIN-rail Dial cover Start push button Side aux. contact Dial cover lock device Test trip device Pad locking (off position) Stop push button Identification label Compact frame size (45 mm) TECHNICAL INFORMATION Parameters Type MB-2 Standard conformity IS / IEC & IS / IEC Utilization category A (Circuit breaker) / AC-3 (Motor duty) Rated thermal current range (Ith) A Rated operational voltage V 690 Rated insulation voltage V 690 Rated operational frequency Hz 50 / 60 Rated impulse with stand voltage kv 6 Breaking capacity (Icu) upto 4kW / 5.5-9kW / 15kW ka 100 / 15 / 10 Breaking capacity (Ics % of Icu) upto 4kW / kW / 9kW / 11kW % 100 / 50 / 40 / 50 Power dissipated per pole W 2.5 Mechanical life (C.O.) No.of ops. 0.1 million Duty class (Max. operating rate) C.O. / hr 25 Rated duty Continuous Degree of protection open / enclosed IP-20 / IP-65 Shock resistance 30 gn-11ms Vibration resistance 5 gn Ambient temperature range C -20 to +60 Max. operating altitude m 2000 Suitable for isolation Yes Phase failure sensitivity Yes Operating position 90 0 on either side off normal vertical mounting plane Terminal capacity Solid cable (Max.) Sq. mm 2 x 6 Flexible cable (Max.) Sq. mm 2 x 6 Tightening torque N.m. 1.7 Weight Kg Dimension mm 44.5 x 89 x

6 TECHNICAL INFORMATION Add on Accessory Type Aux. Contact Fault Signalling Contact Side mounted Front mounted Side mounted Contact configuration (1NO + 1NC) / 2NO (1NO + 1NC) / 2NO 1NO / 1NC Rated insulation voltage ( Ui ) V Rated thermal current ( Ith ) A Utilisation Category AC 15 AC 15 AC 14 Rated operation voltage ( Ue ) V 110 / 240 / / / 240 Rated current A 4.5 / 3.3 / / / 0.3 Mechanical life ( Close - open ) Ops. 1,00,000 1,00,000 1,000 Number of cables / Conductor Cable size (max.) Sq. mm TECHNICAL INFORMATION Add on Accessory Type Under Voltage Trip (UVT) Shunt Trip ( ST) Side mounted Side mounted Rated insulation voltage (Ui) V Operation current V Un Un Drop out voltage V Un Un Power consumption (inrush) VA Power consumption W Power consumption (sealed) VA Power consumption W Operating time ms Number of cables / Conductor 1 / 2 1 / 2 Cable size (Max.) Sq. mm Tightening torque Nm Mechanical life (Close - open) Ops. 1,00,000 1,00,000 6

7 MOTOR KW RATING & CURRENT SETTING RANGE 3-phase motor rating AC-3 duty 415 V, 50Hz Thermal Current Setting range Magnetic tripping current kw HP Icu (ka) lcs (%) A A Type MB MB MB MB MB MB MB MB MB MB MB MB MB MB MB2-32 DIMENSION (in mm) X X X - Electrical clearance = 40 mm Standard screw mounting Mounting on (35 x 7.5) Din rail 7

8 TIME - CURRENT CHARACTERISTICS 10,000 1, Time (sec) x the setting current (Ir) 1) 3 poles from cold state 2) 2 poles from cold state 3) 3 poles from hot state LET THROUGH ENERGY (I 2 T) CHARACTERISTICS Thermal limit on short circuit (in magnetic operating zone) Sum of I 2 dt (ka 2 sec) Prospective lsc (ka) (1) A (2) A (3) A (4) A (5) 9-14 A (6) 6-10 A (7) A (8) A (9) A (10) A Sum of I 2 dt = f (prospective lsc) at 1.05 Ue = 435 V 8

9 ADD ON ACCESSORIES Under voltage trip MB2 - UV Side Aux. Contact SM11 / SM20 Shunt Trip MB2 - ST Fault Signalling Contact FC1010 / FC1001 Front Aux. Contact FM11 / FM20 Enclosure MB2 - E CIRCUIT DIAGRAMS (1NO + 1NC) (2NO) (1NO + 1NC) (2NO) C C2 trip (1NO) (1NC) 9

10 ORDERING INFORMATION Note: MB2-22 provide on request Relay Range Type Cat. No MB2-01 IHPMPBA0A MB2-02 IHPMPBB0B MB2-03 IHPMPBC0C MB2-04 IHPMPBD0D MB2-05 IHPMPBE0E MB2-06 IHPMPBF0F MB2-07 IHPMPBG0G MB2-08 IHPMPBH0H MB2-10 IHPMPBJ0J MB2-14 IHPMPBK0K MB2-16 IHPMPBL0L MB2-20 IHPMPBM0M MB2-21 IHPMPBN0N MB2-22 IHPMPBQ0Q MB2-32 IHPMPBP0P0 ADD ON ACCESSORIES Accessory Type Cat. No. Side aux. contact (1NO+1NC) MB2 - SM11 ISPMASM011 Side aux. contact (2 NO) MB2 - SM20 ISPMASM020 Front aux. contact (1NO+1NC) MB2 - FM11 ISPMAFM011 Front aux. contact (2NO) MB2 - FM20 ISPMAFM020 Fault signalling contact (1NO) MB2 - FC1010 ISPFC010 Fault signalling contact (1NC) MB2 - FC1001 ISPFC001 Shunt trip 110 V 220 V 380 V / 415 V MB2 - ST1 MB2 - ST2 MB2 - ST3 ISPST110 ISPST220 ISPST415 Under voltage trip 110 V 220 V 380 V / 415 V MB2 - UV1 MB2 - UV2 MB2 - UV3 ISPUV110 ISPUV220 ISPUV415 MPCB Enclosure (IP 65) MB2 - E IHPMB2 E0 10

11 REGIONAL BRANCH OFFICES NORTH - REGIONAL OFFICE : Delhi : QRG Towers, 2D, Sector-126, Expressway, Noida Noida : Tel: , Fax: Chandigarh : Tel: , Fax: , Dehradun : Tel: , Haryana : Tel: / 853, Fax: Noida : Tel: / , Fax: Ludhiana : Tel: / 6024, Fax: Jammu : Tel: , Fax: Jaipur : Tel: , Fax: Lucknow : Tel: , Kanpur : Tel: Airtel: /52/53, /129/130, Fax: EAST - REGIONAL OFFICE : Kolkata : ICC Tower, 5th Floor, 4 India Exchange Place, Kolkata Kolkata : Tel: /52, Fax: Bhubaneshwar : Tel: , , , Fax: Guwahati : Tel: , , Fax: Siliguri : Tel: (RIM) Jamshedpur : Tel: , Patna : Tel: , , Telefax: WEST - REGIONAL OFFICE : Mumbai : 302, Boston House, 3rd Floor Suren Road, CTS No. 260/261, Andheri (E), Mumbai Mumbai : Tel: Ahmedabad : Tel: , , Fax: Indore : Tel: , (Airtel), Fax: Rajkot : Tel: / Nagpur : Tel: , , Pune : Tel: /14 Raipur : Tel: / 01, Telefax: Surat : Telefax: SOUTH - REGIONAL OFFICE : Chennai : Block 1, A & D Wing, Shakthi Towers, 7th Floor, 766, Annna Salai, Chennai Chennai : Tel: , Fax: Bangalore : Tel: , / 2 / 3 /4, Fax: Coimbatore : Telefax: , , Hyderabad : Tel: , , , /0408/6401/6402, Fax: Kochi : Tel: , , , Fax: Vishakapatnam : Tel: , Fax: REPRESENTATIVE OFFICES Goa Solapur Gwalior Jabalpur Hubli Davanagere Gulbarga Mysore Trichny Kathmandu Sambalpur Jalandhar Bhopal Calicut Madurai Trivandrum

12 ACB MCCB Digital MCCB MCCB Panel Board Euroload Change Over Switch Submersible & Motor Starter Switch Disconnector Fuse Load Changeover Switch Camlock fuse holder HRC Fuse Motor Low Voltage Capacitor Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication. Specifications and performance data are constantly changing. Current details should therefore be checked with Havells Group. ZHIMC00008/FEB2011 Havells India Ltd. Corp Office: QRG Towers, 2D, Sector-126, Expressway, Noida (U.P), Ph , Consumer Care No.: (Tollfree), (Landline) (All Connections) Join us on Facebook at and share your ways to save the planet!

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Energy Efficient 3 Phase LV Induction Motors

Energy Efficient 3 Phase LV Induction Motors Energy Efficient 3 Phase LV Induction Motors Revision-8 About us HHavells India Ltd is a billion-dollar-plus organization, and is one of the largest & India s fastest growing electrical and power distribution

More information

LET THE SUN POWER YOUR HOME

LET THE SUN POWER YOUR HOME LET THE SUN POWER YOUR HOME Havells Residential Solar Grid-Tie Inverter 7 Years Introduction of Havells Havells India Limited is a leading Fast Moving Electrical Goods (FMEG) Company and a major power

More information

LT/HT Power & Control Cables

LT/HT Power & Control Cables LT/HT Power & Control Cables Price List w.e.f. July, 1 (Rev. 01) HT Single Core Power Cables HT Three Core Power Cables LT Aluminium Power Cables LT Copper Cables - Power and Control ISO-9001/ 1001/18001

More information

& Mini Mast Solution HIGHEST SP 1A SOLAR GRADING. Performance Monitoring with Bluetooth

& Mini Mast Solution HIGHEST SP 1A SOLAR GRADING. Performance Monitoring with Bluetooth Solar LED Street Light & Mini Mast Solution HIGHEST SP 1A SOLAR GRADING Performance Monitoring with Bluetooth Solar Street Light System A LED based solar street lighting system consists of a Solar PV Module,

More information

Energy Efficient 3 Phase

Energy Efficient 3 Phase Energy Efficient 3 Phase LV Induction Motors LIST PRICE w.e.f. 1 st Nov, 2017 (rev. 1) IE3 & IE2 Brake Motor Inverter Duty IE3 IE2 18% *GST *Subject to change as per Govt. notification Havells Lafert Motors

More information

Consumer Luminaires PRICE LIST w.e.f. 1st April 2009

Consumer Luminaires PRICE LIST w.e.f. 1st April 2009 Consumer Luminaires PRICE LIST w.e.f. 1st April 2009 LED RANGE Endura Lite COMBO PACK Endura lite SILVER FINISH FIXTURE Enduralite, ultra bright LED spot light with 360 0 swivel fixture and electronic

More information

Modular Plate Switches

Modular Plate Switches Modular Plate Switches PRICE LIST w.e.f. 1st April 2015 New Introductions ENERGY SAVING PORTABLE LAMP WITH PIR SENSOR A passive infrared sensor (PIR sensor) is an electronic sensor that measures infrared

More information

Domestic & Industrial Switchgear. Switchgear

Domestic & Industrial Switchgear. Switchgear Domestic & Industrial Switchgear Switchgear PRICE LIST w.e.f. 1st Aug., 2014 Distribution Boards Switchgear Electrical energy has brought along with it a lot of conveniences, beyond imagination. It s consumption

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Young energy gives you more air delivery

Young energy gives you more air delivery Young energy gives you more air delivery Fan Booklet 2015 about STANDARD STANDARD, a part of $1.4 Billion leading Fast Moving Electrical Goods (FMEG) Company, Havells India Ltd., offers a wide range of

More information

Record SL. Moulded Case Circuit Breaker

Record SL. Moulded Case Circuit Breaker Record SL Moulded Case Circuit Breaker The new GE Record SL Moulded Case Circuit Breaker family is a line of reliable, simple and easy to use protection devices for use in both moderate or hot and humid

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

More Power More Revenue More Insight

More Power More Revenue More Insight More Power More Revenue More Insight Highest SP 1A Solar Grading Solar Hybrid Catalogue 2017 Hybrid Solar Power Conditioning Unit 1KW to 10KW Single Phase About Havells Havells India Limited is a leading

More information

The Young Energy Lasts Longer

The Young Energy Lasts Longer The Young Energy Lasts Longer Switches Catalogue & Price list Price List 11th April 2016 CORPORATE OFFICE About STANDARD STANDARD is a part of $1.4 Billion leading Fast Moving Electrical Goods (FMEG) Company,

More information

Energy Efficient 3 Phase LV Induction Motors

Energy Efficient 3 Phase LV Induction Motors Energy Efficient 3 Phase LV Induction Motors Motors Price List w.e.f. 3rd May, 2016 IE2 & IE3 EFF2 & EFF1 Inverter Duty Crane Duty IE3 IE2 Havells Lafert Motors Price List w.e.f. 1st August 2013 About

More information

Switches that last longer.

Switches that last longer. Switches that last longer. Switches Catalogue & List Price w.e.f. 1 st July 2017 CORPORATE OFFICE About STANDARD STANDARD is a brand of India s leading FMEG company, Havells India Ltd., that offers a wide

More information

Consumer Luminaires PRICE LIST w.e.f. 1st Sep. 2009

Consumer Luminaires PRICE LIST w.e.f. 1st Sep. 2009 Consumer Luminaires PRICE LIST w.e.f. 1st Sep. 2009 LED RANGE Endura Lite COMBO PACK Endura lite SILVER FINISH FIXTURE Enduralite, ultra bright LED spot light with 360 0 swivel fixture and electronic driver

More information

LABOUR CHARGES - BODYPAINT JOBS. Applicable for Group I+ Cities New GenVerna (HCi)

LABOUR CHARGES - BODYPAINT JOBS. Applicable for Group I+ Cities New GenVerna (HCi) Applicable for Group I+ Cities New Gen / / with Clear / / TLi / / / / / / / with Clear with Clear 44 390 67 4990 880 08 880 08 629 440 880 08 690 82 98 220 6840 649 7740 737 6830 810 904 9430 938 981 981

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

MPCB. We touch your electricity everyday! State of the art Manufacturing Facilities. Haridwar, Noida Ph-I & Noida Ph-II Plant

MPCB. We touch your electricity everyday!   State of the art Manufacturing Facilities. Haridwar, Noida Ph-I & Noida Ph-II Plant www.cselectric.co.in We touch your electricity everyday! State of the art Manufacturing Facilities Haridwar, Noida Ph-I & Noida Ph-II Plant IS: 8828 C&S Electric Ltd. We touch your electricity everyday!

More information

Motor Protection Circuit Breakers

Motor Protection Circuit Breakers Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

Spectronic SP Air Circuit Breaker. Protecting people, property & productivity

Spectronic SP Air Circuit Breaker. Protecting people, property & productivity Spectronic SP Air Circuit Breaker Protecting people, property & productivity Spectronic SP Air Circuit Breaker Circuit Breakers 800 to 2500A Series SP Rated short circuit breaking capacity : lcs 50 / 55KA

More information

Spectronic SP Air Circuit Breaker. Protecting people, property & productivity

Spectronic SP Air Circuit Breaker. Protecting people, property & productivity Protecting people, property & productivity Circuit Breakers 800 to 2500A Series SP Rated short circuit breaking capacity : lcs 50 / 55KA ( 415V) Complete range Fixed with manual control 3 or 4 Poles The

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

Spectronic-SP Air Circuit Breaker

Spectronic-SP Air Circuit Breaker Spectronic- Air Circuit Breaker Circuit Breakers 800 to 2500A Series Rated Short circuit breaking capacity : lcs 50 to 55KA ( 4 15V) Complete range Fixed with manual control 3 or 4 poles Electrical control

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

Manual changeover switches & Automatic transfer switches

Manual changeover switches & Automatic transfer switches Manual changeover switches & Automatic transfer switches Manual ChangeoverSwitches 63A to 1600A Advantagesforyou: Doublebreakperpolefacilitalingsuitabilityforisolationasper IEC60947-3 Safeisolationat0positionformaintenance

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Consumer Luminaires PRICE LIST w.e.f. 1st July, 2012

Consumer Luminaires PRICE LIST w.e.f. 1st July, 2012 Consumer Luminaires PRICE LIST w.e.f. 1st July, 2012 LED RANGE ENDURA PLATE ENDURA LITE COMBO PACK Cutout size Ø 75 mm SILVER FINISH FIXTURE Enduralite, ultra bright LED spot light with 360 0 swivel fixture

More information

Industrial Circuit Protection

Industrial Circuit Protection Industrial Circuit Protection Catalogue 2011 Content Contactor... 2-31 Thermal Overload Relay... 32-45 Capacitor Duty Contactor... 46-51 Motor Protection Circuit Breaker... 52-59 Titania Air Circuit

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Manual Motor Starters

Manual Motor Starters Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC

More information

DRX. MCCBs for residential and commercial SYSTEMS FOR ELECTRICAL INSTALLATIONS & INFORMATION NETWORKS.

DRX. MCCBs for residential and commercial SYSTEMS FOR ELECTRICAL INSTALLATIONS & INFORMATION NETWORKS. DRX MCCBs for residential and commercial SYSTEMS FOR ELECTRICAL INSTALLATIONS & INFORMATION NETWORKS www.legrand.co.in Combining forces to provide power and protection With offers in more than 160 countries,

More information

EVERY DRILL DIESEL ENGINES FOR COMPRESSOR APPLICATIONS. - Pdf manuals & parts catalogs library

EVERY DRILL DIESEL ENGINES FOR COMPRESSOR APPLICATIONS.  - Pdf manuals & parts catalogs library R EVERY DRILL DIESEL ENGINES FOR COMPRESSOR APPLICATIONS FOR COMPRESSOR APPLICATIONS. Cummins Presence in Compressor Industry One that keeps your package performing optimally, while keeping the maintenance

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

INTERNATIONAL FREIGHT

INTERNATIONAL FREIGHT ANNEXURE-IVA INTERNATIONAL FREIGHT (A) 20 INTERNATIONAL S 1 CHENNAI 27035 25605 5.6 52663 49971 5.4 2 KOLKATA 4800 6027-20.4 9351 10918-14.4 3 AHMEDABAD 3910 3800 2.9 7222 6910 4.5 4 GOA 126 104 21.2 244

More information

DRX 100 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

Motor Protection Circuit Breakers 3VU13 and 3VU16

Motor Protection Circuit Breakers 3VU13 and 3VU16 Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

Capacity : 5 tons Engine Power : 79 bhp. High Performance & rugged Forklift Trucks.

Capacity : 5 tons Engine Power : 79 bhp. High Performance & rugged Forklift Trucks. Capacity : 5 tons Engine Power : 79 bhp. High Performance & rugged Forklift Trucks. Stiff Boom Cranes Motor Grader PTR Model Load Capacity Power Tyres Wheel (s) Fork Height (std.) Fork Size (LxWxT) Tilt

More information

INTERNATIONAL PASSENGERS

INTERNATIONAL PASSENGERS ANNEXURE-IIIA INTERNATIONAL PASSENGERS (A) 20 INTERNATIONAL S 1 CHENNAI 517067 472427 9.4 2544451 2304518 10.4 2 KOLKATA 219052 205611 6.5 1097596 1026969 6.9 3 AHMEDABAD 171380 143821 19.2 823520 705823

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Range : 7.5kW to 630/800kW

Range : 7.5kW to 630/800kW Range : 7.5kW to 630/800kW ATS 48 PRESENTATION Altistart 48 is a high performance soft starter using 6 thyristors for controlled starting of 3 phase asynchronous squirel cage induction motors. It provides

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Catalog. Low voltage General performance IE3 efficiency cast iron motors

Catalog. Low voltage General performance IE3 efficiency cast iron motors Catalog Low voltage General performance IE3 efficiency cast iron motors ABB Motors and Generators I Low voltage general performance IE3 efficiency motors 2 General performance IE3 efficiency cast iron

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

ML 1.5 SS91851 ML 2 SS A 25 A 40 A 13.5 A 17 A 37 A 37 A. 6.3 A 15.5 A 15.5 A 12.5 A 23 A 23 A 19 A 830 V 415 V 500 V 3 kvar 120 A

ML 1.5 SS91851 ML 2 SS A 25 A 40 A 13.5 A 17 A 37 A 37 A. 6.3 A 15.5 A 15.5 A 12.5 A 23 A 23 A 19 A 830 V 415 V 500 V 3 kvar 120 A ML Series Contactor & Thermal Overload Relay Technical Data Type Cat. No. Conformance Standards No.of poles Thermal rating / Utilization category AC-1 :, 415V, 50Hz* Insulation voltage, U (V) I) Stator

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

Bistable Relay. Types PSU6n, PSU14n.

Bistable Relay. Types PSU6n, PSU14n. Bistable Relay Types PSU6n, PSU14n. ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

Gas Recombination Vent Plug for Flooded Lead Acid Batteries

Gas Recombination Vent Plug for Flooded Lead Acid Batteries Gas Recombination Vent Plug for Flooded Lead Acid Batteries Dr S N Joshi, DirectorTechnical, Greenvision Tech. Pvt. Ltd. M.S.Hegde, Solid State structural chemistry, Indian Institute of Sciences, Bangalore.India.

More information

Spectra SP. Range of SD & SDF 32A to 800A

Spectra SP. Range of SD & SDF 32A to 800A NEW Spectra SP Range of SD & SDF 32A to 800A Spectra SP Switches - Introduction 01 SPECTRA SP range of SFU GE Energy - Industrial solutions, present SPECTRA SP range of switch disconnector fuse units.

More information

Domestic Switchgear Price List 25th March 2017

Domestic Switchgear Price List 25th March 2017 Domestic Switchgear Price List 25 th March 2017 2 CORPORATE OFFICE About STANDARD STANDARD is a part of $1.4 Billion leading Fast Moving Electrical Goods (FMEG) Company, Havells India Ltd. The company

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Auxiliary Relay. Type RXP8n, RXPQ8n

Auxiliary Relay. Type RXP8n, RXPQ8n Auxiliary Relay Type RXP8n, RXPQ8n ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering

More information

Single Phase Submersible Pump Starters

Single Phase Submersible Pump Starters Single Phase Submersible Pump Starters Starters Single Phase Submersible Pump Starter BCH Electric Limited manufactures a wide range of motor starters to suit every application in the field. BCH introduces

More information

Data Sheet Manual Motor Starters Ex9SN Series

Data Sheet Manual Motor Starters Ex9SN Series Data Sheet Manual Motor Starters Ex9SN Series www.noarkusa.com NOARK Ex9SN Series Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Smart. Shiny. Solar Powered. All-in-One. Solar Street Light

Smart. Shiny. Solar Powered. All-in-One. Solar Street Light Smart. Shiny. Solar Powered. All-in-One Solar Street Light All-in-One Solar Street Light Perfect solutions in street lighting Introducing Sunsoko All-in-One, from the house of Sunsoko, a revolutionary

More information

Price list 03/2018. w.e.f. April 1, 2018

Price list 03/2018. w.e.f. April 1, 2018 list 03/18. w.e.f. April 1, 18 Sl.No. Cable Size Box Dimensions (LXBXH) (mm) WITHOUT WITH TERMINALS TERMINALS Cable Junction Boxes IP with membranes for cable entry - sq.mm 76 x 76 x 3 DE 92 170.00 DE

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC

More information

COMPLETE SOLUTIONS FOR POWER PROTECTION

COMPLETE SOLUTIONS FOR POWER PROTECTION COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

DC MOTORS. Crompton Greaves EVERYDAY SOLUTIONS

DC MOTORS. Crompton Greaves EVERYDAY SOLUTIONS Crompton Greaves EVERYDAY SOLUTIONS DC MOTORS LT MOTORS DIVISION A - 6/2, M.I.D.C., AHMEDNAGAR - 414111. MAHARASHTRA. TEL : +91 (0241) 2776 151-154, 2776146, 2776187. FAX : +91 (0241) 2777508 INTRODUCTION

More information

Domestic Switchgear. List Price w.e.f. 1 st December 2018

Domestic Switchgear. List Price w.e.f. 1 st December 2018 Domestic Switchgear List Price w.e.f. 1 st December 2018 CORPORATE OFFICE STANDARD is a key brand of Havells India Ltd., India s leading FMEG Company that offers a wide range of highly differentiated Domestic

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS 87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation Motor-protectivecircuit-breaker,3p,Ir=2.5-4A Partno. PKZM01-4 Articleno. 278482 CatalogNo. XTPB004BC1 Deliveryprogramme Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton

More information

Short form catalogue Motor protection and control Manual motor starters

Short form catalogue Motor protection and control Manual motor starters Short form catalogue Motor protection and control Manual motor starters Motor protection and control Index Contents Beneifits 4 Features 5 Overview 6 Manual motor starter MS116 and MS132 8 Manual motor

More information

Metal Clad VCBs ~ Mk1

Metal Clad VCBs ~ Mk1 Metal Clad VCBs ~ Mk1 DUVI 150/40 ROLL ON FLOOR VCBs Range: 6kV, 00A, 1.5kA, 12kV, 150A, 40kA ( 4A000A Bus-Bars ) ` Widest range for MV (up to 6kV) Distribution Networks Megawin make metal clad VCB Panels

More information

A9K. MCB, RCCB, Isolator

A9K. MCB, RCCB, Isolator A9K MCB, RCCB, Isolator Schneider Electric - The global specialist in energy management and automation brings 80 years of experience to India with more than 70,000 people in over a 00 countries We Reduce

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information