1 Contactors & Overload relays Metasol MC 3P 18 to 100 MC type Magnetic Contactors Frame size screws clamp terminals Number of poles Rated operational voltage, Ue Rated insulation voltage, Ui Rated frequency Maximum operating rate in operating cycles per hour(c3) Durability Mechanical Electrical Current C1, Thermal current and C3 200/2V kw power 380/4V kw 500/550V kw kw UL rating Continuous current () Single 110~120V HP phase 220~2V HP 200~208V HP Three 220~2V HP phase 4~480V HP 550~600V HP NEM size Size C Weight kg and control Size(WHD) mm weight DC Weight kg control Size(WHD) mm uxiliary(standard) uxiliary Side mount Front mount Note) Minimum conduct current of uxiliary contactor is DC 17V 5m. 18F MC6a MC9a MC12a MC18a 15 mil. operations 2.5 mil. operations a or 1b U1 U2, U4 22F MC9b MC12b MC18b MC22b * 15 mil. operations 2.5 mil. operations a1b U1 U2, U4 MT type Thermal Overload Relays Screws clamp terminals Rated operational voltage, Ue Rated insulation voltage, Ui Trip class Setting range Size Weight kg and weight Size(WHD) mm * The safety cover of magnetic contactor and thermal overload relay is optional. 12 MT12/ 10, ~ MT32/ 10, ~
2 F MC32a MCa 12 mil. operations 2 mil. operations F MC50a MC65a 12 mil. operations 2 mil. operations F MC75a MC85a MC100a 12 mil. operations 2 mil. operations U1 U2, U4 U1 U2, U4 U1 U2, U4 MT32/ 10, ~ 0.17 MT63/ 10, 20 4~ /0.33 MT95/ 10, 20 7~ /
3 Contactors & Overload relays Metasol MC 3P 150 to 800 MC type Magnetic Contactors Frame size screws clamp terminals Number of poles Rated operational voltage, Ue Rated insulation voltage, Ui Rated frequency Maximum operating rate in operating cycles per hour(c3) Durability Mechanical Electrical Current C1, Thermal current and C3 200/2V kw power 380/4V kw 500/550V kw kw UL rating Continuous current () Single 110~120V HP phase 220~2V HP 200~208V HP Three 220~2V HP phase 4~480V HP 550~600V HP NEM size Size C Weight kg and control Size(WHD) mm weight DC Weight kg control Size(WHD) mm uxiliary(standard) uxiliary Side mount Front mount 150F MC130a MC150a 5 mil. operations 1 mil. operations U1 U2, U4 225F MC185a MC225a 5 mil. operations 1 mil. operations U100 (Max.4NO4NC) MT type Thermal Overload Relays Screws clamp terminals Rated operational voltage, Ue Rated insulation voltage, Ui Trip class Setting range Size Weight kg and weight Size(WHD) mm MT150/ 10, 20 34~ MT225/ 10, 20 65~ * The safety cover of magnetic contactor and thermal overload relay is optional. 14
4 0F MC265a MC330a MC0a 5 mil. operations 2.5 mil. operations 1 mil. operations 0.5 mil. operations U100 (Max.4NO4NC) 800F MC500a MC630a MC800a 2.5 mil. operations 0.5 mil. operations U100 (Max.4NO4NC) MT0/ 10, 20 85~ MT800/ 10, ~
5 Contactors & Overload relays Metasol MC 4P 18 to 85 MC type Magnetic Contactors Frame size Screw clamp terminal Number of poles Rated operational voltage (Ue) Rated insulation voltage (Ui) Rated frequency Maximum operating rate in operating cycles per hour(c1) Durability Mechanical Electrical Current Thermal current and C1 200/2V kw Power 380/0V kw 500/550V kw kw UL rating Continuous current () Single 110~120V HP Phase 220~2V HP 200~208V HP Three 220~2V HP Phase 4~480V HP 550~600V HP NEM Size Size C Weight kg and Control Size(WHD) mm weight DC Weight kg uxiliary(standard) uxiliary Control Size(WHD) mm Side Mount Front Mount 18F MC6a/4 MC9a/4 MC12a/4 MC18a/4 15 mil. Operations 0.5 mil. Operations 0.8 mil. Operations U1 U2, U4 16
6 22F MC22a/4 15 mil. Operations 1 mil. Operations U1 U2, U4 F MC32a/4 MCa/4 15 mil. Operations 1 mil. Operations U1 U2, U4 85F MC50a/4 MC65a/4 MC75a/4 MC85a/4 12 mil. Operations 1 mil. Operations U1 U2, U4 17
7 Contactors & Overload relays Metasol MC 4P 225 to 800 MC type Magnetic Contactors Frame size Number of poles Rated operational voltage (Ue) Rated insulation voltage (Ui) Rated frequency and Control Size(WHD) mm * FL = 722, LR = 5618 ** FL = 566, LR = 4495 Screw clamp terminal Maximum operating rate in operating cycles per hour(c1) Durability Mechanical Electrical Current Thermal current and C1 200/2V kw Power 380/0V kw 500/550V kw kw UL rating Continuous current () Single 110~120V HP Phase 220~2V HP 200~208V HP Three 220~2V HP Phase 4~480V HP NEM Size 550~600V HP Size C Weight kg weight DC Weight kg uxiliary(standard) uxiliary Control Size(WHD) mm Side Mount Front Mount 225F MC100a/4 MC130a/4 MC150a/4 MC185a/4 MC225a/4 5 mil. Operations 0.8 mil. Operations U100 18
8 0F MC265a/4 MC330a/4 MC0a/4 2.5 mil. Operations 0.5 mil. Operations F MC500a/4 MC630a/4 MC800a/4 2.5 mil. Operations 0.5 mil. Operations * ** U100 U100 19
Metasol MC 4pole. Contactor. Overview 108 Table of specifications 110 Dimension 114. Contents
Metasol MC Contactor Overview 8 Table of specifications 1 Dimension 114 Contents Series completion More Safe, More Valuable Contactors & Overload Relays dvanced technology & Expert solution Offering economical
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays New generation of Contactors from LS Industrial Systems Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol
More informationIDEC YC Contactors. New Contactors Now Available
New ors Now vailable IDEC YC ors TOC & Selection Guide YC ors Table of Contents Selection Guide...2 YC1N(K) Mini ors...3...3 ccessories...5 Specifi cations...5 Dimensions...6 Electrical Diagrams...6 YC1U
More informationA200 NEMA Contactors and Starters A200
Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws
More informationSubmittal Data Information
Effective: NOVEMBER 3, 2014 JOB CONTRCTOR ITEM NO. Submittal Data Information TS - Taco dvanced Starter ENGINEER REP. 301-2690 Supersedes: NEW TS - Taco dvanced Starter 1Ø, 120-230V, 1/10-30HP 3Ø, 200-600V,
More informationMotor Starting Solutions Open Type Version, in Kit Form
Motor Starting Solutions Open Version, in Kit Form Starters Protected by Manual Motor Starters Direct-On-Line Starters I> Reversing Starters I> MS... Manual motor starter MS... Manual motor starter BEA...
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More informationKtec Contactors and thermal overloads
Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America
More informationNB1 Miniature Circuit Breaker
P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide
More informationSubmittal Data Information
Effective: NOVEMBER 3, 2014 JOB CONTRACTOR ITEM NO. Submittal Data Information TDX - Taco Duplex Starter ENGINEER REP. 301-2693 Supersedes: NEW TDX - TACO DUPLEX STARTER 1Ø, 230V, 1/10-15HP 3Ø, 200-460V,
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationLSIS Electric Products MCB / MC&TOR / MMS / MCCB / ACB / FDB / SMDB / VCB
www.lsis.com LSIS Electric Products MCB / MC&TOR / MMS / MCCB / CB / FDB / SMDB / VCB 1, 2, 3 and 4 pole series up to 125F B, C and D Characteristics 2 and 4 pole series up to 100F Sensitivity up to 300m
More informationBulletin 190-M Compact Starters. Selection Guide
Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located
More informationP-SERIES VFD WITH BYPASS
P-SERIES VFD WITH BYPSS 1 40 HP (200~230 VC) 1 100 HP (380~480 VC), 3Ø Enclosed Bypass - UL Type 3R Standard Controls for Bypass & Local/Remote Operation Special Instructions: FETURES ND OPTIONS Compact
More informationProtection components
Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed
More informationB6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data
B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More informationEW series Industrial contactors
2012_EW_Contactors_bro_EN.qxd:Mise en page 1 31/08/12 10:24 Page 2 EW series Industrial contactors Hager offers a complete range of contactors for commercial market such as buildings, infrastructures,
More informationC -5 to +55 (0.8 to 1.1Uc) Permissible o
T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4
More informationMolded case circuit breakers
Molded case circuit breakers Metasol 30F to 250F Series Type Type and Pole Rated current, In Rated operational voltage, Ue Rated insulation voltage, Ui Rated impulse withstand voltage, Uimp Frame Size(F)
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationManual motor starter magnetic only MO325
Data sheet Manual motor starter magnetic only MO325 Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF
More informationContactors (9 to 85A)
Contactors (9 to 85A) Frame size 9A 12A 18A 22A -pole Contactors For further technical information see pages 8-9. includes AU-1 auxililary switch, (1 N.O. / 1 N.C.) Types AC coil DC coil GMC-9 GMD-9 GMC-12
More informationIndustrial contactors CTX-1
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationMini contactors. Mini contactors providing various connections and Accessories. Screw clamps. Ratings. For fast-on connections
Mini contactors providing various connections and Accessories Screw clamps Fast-on Ratings AC3 ratings (IEC609-) Frame size 220 ~ 280 ~ 0 ~ 20V 0V 5V 690V 6A 1.5kW 2.2kW 3kW 3kW A 6A 5A A 9A 2.2kW kw 3.kW
More informationTechnical Information
C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationCircuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63
Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationASL09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil
More informationEfficor* Intro. Conformity to standards. Ambient conditions. Climatic resistance (IEC 68-2) Approvals/Marking. Mounting positions
fficor* onformity to standards /N 60947-1 04 /N 60947-4-1 UL508 /N 60947-5-1 UL486 /N 60947-5-4 S22- N500 N 16 101/102 N50012 N50005 pprovals/marking mbient conditions Storage temperature -55º to +80º
More information22AF 40AF AF 150AF 225AF 400AF 800AF
Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug
More informationMolded Case Circuit Breakers
Molded Case Circuit Breakers Cerus TD and TS Series UL 489 Listed TD125U ln 15~125A 3.54(W) x 6.46(H) X 3.39in (D) TS250U ln150 ~ 250A 4.13 (W) x 7.01 (H) X 3.39in (D) TS400U ln 300 ~ 400A 5.51 (W) x 11.50
More informationESW/PESW. Non-Combination Starters
ESW/PESW Enclosed Non-Combination General WEG offers non-reversing and non-combination magnetic starters up to 75HP at 460Vac (105). Featuring components that meet IEC design standards and UL horsepower
More informationRSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX
IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationUS catalog. R contactors Control of AC and DC power circuits up to 5000 A
US catalog R contactors Control of AC and DC power circuits up to 5000 A Motor rated operational powers and currents The currents given below concern standard three-phase four-pole cage motors (1500 r.p.m.
More informationVB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated
VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control
More informationIEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101
IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With
More information[V] Common Control Transformer Control (See page 1-78 Note)
Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state
More informationContactors and Overloads MC
Contactors and Overloads MC Up to 700A AC3 Up to 00A AC1 DIN rail mounting to 5A, 55kW Add on auxiliary contacts top or side mounted International approvals Designed to EN60971 Compact design for panel
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More informationContact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France
Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on
More information1 Phase electronic contactor (SC 1)
1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationOverload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure
Overload Relays Thermal (Bimetallic) style up to 800A CGT type overload relays are designed for the easy mounting directly to contactors or separately by using additional bases or brackets. Relays frame
More informationOverload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure
Overload Relays Thermal (Bimetallic) style up to 800A CGT type overload relays are designed for the easy mounting directly to contactors or separately by using additional bases or brackets. Relays frame
More informationLSIS Electric Products. ACB / MCCB / MCB / MC&TOR / Mini-MS / MMS / EMPR
LSIS Electric Products ACB / MCCB / MCB / MC&TOR / Mini-MS / MMS / EMPR Susol series 85, 100 and 130kA short circuit current with instantaneous at 508V High functional digital trip relays UL approved Page
More informationMINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS
MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY
More informationShort-Circuit Current Ratings
UL 508 Type E Combination Motor Controller, TeSys GV Combination Meeting UL 508 Type E, UL File E164871 Table 2: TeSys GV2P Horsepower and SCCR Ratings In combination with line spacer GV2GH7 (stand-alone
More informationBrochure. Motor protection and control DRAS enclosed direct-on-line starters
Brochure Motor protection and control DRS enclosed direct-on-line starters DRS09 DRS16 enclosed direct-on-line starters 4 to 7.5 kw, protected by thermal overload relays C or DC operated DRS + T16 to
More informationThermal-magnetic Miniature Circuit Breaker 4230-T...
Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail
More informationMAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-
MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4
More informationThermal overload relays, Class 10A
Thermal overload relays, Class 10A 22A GT-22 - Direct on the GM-9, 12, 18, 22 contactors (9, 12, 18, 22A frames) - DIN rail or screw able with the optional base AZ-22H - Small physical size : 44 mm wide
More informationSeries CK. Contactors. Intro. Mounting positions
onformity to standards /N 60947-1 N 63-110 S 5424 & 775 /N 60947-4-1 S 1025 NM S 1 NL 419 S 22.2/14 V 0660/102 UL 508 UN 20109 N 50005 pprovals/marking culus RN NOM Lloyd s Register ureau Veritas mbient
More informationQuestion Number: 1. (a)
Session: Summer 2008 Page: 1of 8 Question Number: 1 (a) A single winding machine cannot generate starting torque. During starting the switch connects the starting winding via the capacitor. The capacitor
More informationStarting of Induction Motors
1- Star Delta Starter The method achieved low starting current by first connecting the stator winding in star configuration, and then after the motor reaches a certain speed, throw switch changes the winding
More informationMAGNETIC CONTACTOR & MOTOR STARTER
http://www.seec.com.tw http://circuit-breaker.seec.com.tw MAGNETIC CONTACTOR & MOTOR STARTER P Functionalities and characteristics of Magnetic Contactor Configuration Composite magnetic switch (abbreviated
More informationMAGNETIC CONTACTOR & MOTOR STARTER
http://www.seec.com.tw http://circuit-breaker.seec.com.tw MAGNETIC CONTACTOR & MOTOR STARTER P Functionalities and characteristics of Magnetic Contactor Configuration Composite magnetic switch (abbreviated
More informationInstallation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue
FAQs I have installed the ATS panel but it won t go into the mains supply? First check all cables are in place and properly installed and that the control fuses (A-C on page 4) have not blown. If it still
More informationXT IEC Power Control Manual Motor Protectors
May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted
More informationBEST QUALITY & BEST PRICE
www.pownix.com 전자개폐기 Order Code List of AC Technical Information Control Relay Accessories Thermal Overload Relay 70 71 ~ 77 78 ~ 93 94 ~ 97 98 ~ 100 101~ 107 BEST QUALITY & BEST PRICE 70 Best Quality
More informationLOW VOLTAGE SWITCHGEAR
LOW VOLTAGE SWITCHGEAR S-N Motor Control Mitsubishi Electric s S-N Series contactors are perfect for the control of 3 phase power, either for the direct control of a motor, to supply power to a drive or
More informationAF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals
AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.
More informationOverview of Low voltage equipment - Moulded-case & Air circuit-breakers
Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are
More informationAF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationShort-circuit current limiter S800-SCL-SR
Short-circuit current limiter S800-SCL-SR 2 ABB Short-circuit current limiter S800-SCL-SR Self-resetting current limiting module S800-SCL-SR is ABB s innovative self-resetting current limiting module which
More informationAF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits
More informationManual motor starters Overview and benefits
Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection
More informationThermal Overload Relays - WEG RW Series, 2 Pole
International (5) 4-07 The RW Class Thermal Overload Relays, with their extended operational service lives, are designed for use with the CWC miniature and CWM standard contactors. These relays can be
More informationAF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationContactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660
Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,
More informationSMP-2 Overload Relay. Product Selection Overview Feature SMP-1 SMP-2 SMP-3 TABLE OF CONTENTS. Description Page Description Page
3 ulletin 93 ulletin 93 SMP- Overload Relay SMP-3 Overload Relay SMP-2 Overload Relay Product Selection Overview Feature SMP- SMP-2 SMP-3 Self-Powered 3.2: djustment Range Phase Loss Protection Selectable
More informationSIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability
More informationTECHNICAL DESCRIPTION
DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650515200 Ed.1 of 21/02/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationStandard voltages. Alternating current (V) /60Hz Alternating current (V)
Three and four pole contactors 50 to 825 (3) 200 to 250 () ontactors ontrol circuit: lternating current up to 690V irect current up to 500V egree of protection P00 (Pxx with accessories) K07K3: auxiliary
More informationABB s new control and protection devices
ABB s new control and protection devices One product family ABB presents a new generation of first-class specialized components: manual motor starters, contactors, overload relays and softstarters for
More informationApproved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories
Thermal Overload Relay J7TKN ) Thermal Overload Relay Direct and separate mounting Single phasing sensivity according to IEC 60947-4-1 Finger proof (BGV A2) Accessories Set for single mounting Approved
More informationStandard voltages. Alternating current (V) /60Hz Alternating current (V)
Three and four pole contactors 50 to 825 (3) 200 to 250 () ontactors ontrol circuit: lternating current up to 690V irect current up to 500V egree of protection P00 (Pxx with accessories) K07...K3: auxiliary
More informationGLOBAL RANGE. Global Range Motor Control. Contactors. Features. Applications. Overload Relays. Features. Applications. Manual Motor Starter Features
GLOBAL RANGE Contactors Overload Relays Features Competitively priced Comprehensive range (AC & DC) Fitted with Auxiliary/s as standard Type coordination Applications Commercial Industrial Mining Features
More informationPERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT
BALDOR -RELIANCE FRAME HP TYPE PHASE HERTZ RPM SALES ORDER 385- O58 5 P 3 6 3576 VOLTS AMPS DUTY AMB o C INSUL S.F. NEMA DESIGN 3 / 46 36 / 8 CONT 4 F.5 --- CODE ENCL. ROTOR WK STATOR RES.@5 o C LETTER
More informationPage 2-4 Page 2-8. Page Page 2-12
Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V
More informationand other modular devices for low voltage installation
Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories
More informationCB to 1000 A. 1 to 4 single pin main poles with silver pad contacts.
LEI-ELEC F 5470 GOCY CB 75 400 to 000 A types for each calibre: AC poles CBA 75 400, CBA 75 500, CBA 75 60, CBA 75 800, CBA 75 000. poles CBFC 75 400, CBFC 75 500, CBFC 75 60, CBFC 75 800, CBFC 75 000.
More information28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description
.1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is
More informationSeries MTO. Thermal overload relays. Thermal overload relays. for minicontactors from 0.11 to 14A. Standards. General characteristics.
Series MTO for minicontactors from 011 to 14 ontrol circuit up to 690V Power circuit up to 690V Three-pole differential (phase unbalance protection) utomatic ambient temperature compensation between 25º
More informationContactors & Starters. Definite Purpose. Definite Purpose Contactors & Starters C-1. Contents
Definite Purpose ontactors & Starters - July 007 Definite Purpose ontactors & Starters ontents Description Page Product Family Overview pplication Description........................................ -
More informationElectric Equipment General Catalog
Electric Equipment General Catalog Magnetic Contactors Thermal Overload Relay Magnetic Contactor Thermal Overload Relay Low Voltage Equipments Contactor Contents Main Features Development Figure of Components
More informationAmbient temperature compensation (-40F to +1400F) Phase loss sensitivity protection, Current unbalance sensitivity.
www.we.net Thermal Overload Relays - RW Series Rated for the new industry RW overload relays are an important part of WEG rane of products. s usual in WEG products, an extended operational service life
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationStandard voltages. Alternating current (V) 50/60Hz Alternating current (V)
Series CK Three and four pole contactors 150 to 825 (C3) 200 to 1250 (C1) Control circuit: lternating current up to 690V Direct current up to 500V Degree of protection IP00 (IPxx with accessories) CK07...CK13:
More informationManual Starters and Switches Integral Horsepower Types M and T
CLASS 510, 511, 51 INTEGRAL HORSEPOWER STARTERS TYPES M AND T Application Data Types M and T integral horsepower manual starters provide convenient On-Off operation of small single phase, polyphase, or