About us. Switchgear Factory, Mumbai

Size: px
Start display at page:

Download "About us. Switchgear Factory, Mumbai"

Transcription

1

2 About us Larsen & Toubro is a technologydriven USD 8.5 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction, Electrical & Electronics, Machinery and Information Technology. L&T Switchgear, which forms part of the Electrical & Automation business, is India's largest manufacturer of low voltage switchgear, with the scale, sophistication and range to meet global benchmarks. With over four decades of experience in this field, the Company today enjoys a leadership position in the Indian market with growing presence in international markets. It offers a complete range of products including controlgear, powergear, motor starters, energy meters, wires and host of other accessories. Most of our product lines conform to international standards, carry CE markings and are certified. Switchgear Factory, Mumbai

3 Range of MNX Contactors & Relays L&T now introduces the MNX range of Contactors and Relays. The most rugged and user friendly Contactors and Relays available today. Three Pole Power Contactors Type MNX Range from 9 AC Conformance to IEC 0971 / IS 1971 Thermal Overload Relays Type MNX R Direct Mounting on MNX Contactor Builtin single phasing protection

4 Pole Power Contactors Catalogue No. Conformance to standards Power Contacts No. of poles Rated insulation voltage, Ui Rated impulse withstand voltage, U i Rated making capacity Amp Rated breaking capacity Amp Conventional thermal current, Ith Utilization category AC1 0 At 55 C Utilization category AC Motor duty : Ø, 15V, 50Hz Utilization category AC Utilization category AC Operational current / e for AC Utilization category at 15V,Ø, 5OHz for,00,000 operating cycles Capacitor switching delta connected: 15V, 50Hz *** Max. Permissible peak inrush current, / p for capacitor switching DC 1 V DC 1 0V DC ratings (with poles in series) DC V and AC coil operation DC 0V DC 5 V DC 5 0V Mechanical life, No. of operating cycles Max. frequency of operations: Operating cycles/hr Service Temperature * With 1NC Auxiliary Contacts ** Data Available on request *** For Capacitor Switching, please connect inductor in series # Add On block can be ordered separately 0Hz & 50/0HZ Coils available on request. Mechanical Utilization Category AC1 Utilization Category AC Utilization Category AC Utilization Category AC Lug (mm ) Link (mm ) Main terminal capacity Solid Conductors (mm ) Multi strand conductors (mm ) Auxiliary Contacts No. of builtin auxiliary contacts 0 Conventional thermal current, / th at 55 C AC15 rating at 15V, 50Hz Terminal capacity (Solid or multi strand conductors (mm ) Coil Voltage available for 50 Hz Uc V Pickup Holdon Limits of operation VA CosØ VA Watts Pickup (%Uc) Dropoff(%Uc) MNX 9 CS 9 / 7* 90V kw / 5.5hp / kw / 5.5hp / 5.5A kvar 570A A 15x C to +55 C 1 x x 1NO or 1NC MNX 1 CS 98 / 9* 90V A 1 5.5kW / 7.5hp / 1 5.5kW / 7.5hp / 1 7.1A 7.5 kvar A 15x C to +55 C 1 x x 1NO or 1NC MNX 18 CS 90 / 1* 90V A 9.kW / 1.5hp / 9.kW / 1.5hp / 8A 9 kvar A 15x C to +55 C 1 x x 1NO or 1NC MNX CS 9980 / 81* 90V 8kV kw / 15hp / kw / 15hp / 8.5A 9 kvar A 15x C to +55 C 1 x x NO or NC,,, 0/0,15, MNX 5 CS 9 90V kw / 15hp / kw / 15hp / 1.5A 15 kvar 0A C to +55 C 1x x x #

5 Technical Data MNX CS 91 MNX0 CS 9190 MNX 5 ST MNX 50 ST MNX 70 ST 1900 IEC 0971, BSEN 0971 & IS 1971 MNX 80 ST 1900 MNX 95 CS 91 MNX CS V A 17kW /.5hp / 17kW /.5hp / 1A 90V A 0A.5kW / 0hp / 0A.5kW / 0hp / 0A 0A 90V A 5kW / hp / 5kW / hp / 90V A kw /5 hp / kw / 5hp / 90V 900 0A 70A 7kW / 50 hp / 70A 0kW / 0hp / A 8.5A 90V 900 0A 0kW / 5 hp / 7kW / 50hp / 70A A 5kW / 0 hp / 5kW / 0hp / 5A A 1 55kW / 75 hp / 1 55kW / 75hp / 1 58A 0 kvar 000A 0A C to +55 C 1x x x 0 kvar 000A 0A 0A 0A 0A 0A C to +55 C 1x x x 0 kvar C to +55 C 1x5 1 x 1.5mm x mm 0 kvar C to +55 C 1x5 1 x 1.5mm x mm 5 kvar A A A A A C to +55 C 1x5 1 x 1.5mm x mm 0 kvar 000A A C to +55 C 1x5 x 1.5mm x mm 5kVAR 500A C to +55 C 1x x 5mm x mm 5kVAR 500A C to +55 C 1x x 5mm x mm # #

6 Technical Data MNX CS 918 MNX 185 CS 919 MNX 5 CS 9 MNX 5 CS 91 MNX 5 CS 91 MNX 00 CS 91 MNX 550 CS 915 MNX 50 CS A A 75kW / 0 hp / A 75kW / 0hp / A A kW / hp / 90kW / hp / A 90A A kw / hp / 0kW / 1hp / 00A 0A A A 17kW / 19 hp / 180kW / 5 hp hp / / 00kW / 70 hp / 00A kw / 175hp / kw // 190hp / / kw / 00hp / 75A A A kW / 5hp / 5 18kW / 5hp / 00A 1 500A 500A 8 55kW / 75hp / 00kW / 7hp / 00A ** 70kVAR 000A C to +55 C 1x x 5mm x mm 0kVAR 500A C to +55 C 1x185 x 0mm x 5mm 15kVAR 500A C to +55 C 1x185 x 0mm x 5mm kvar 0A C to +55 C x0 / 1x00 x 50mm x 5mm 175kVAR 7000A C to to +55 C x0 / / 1x00 x x 50mm x x 5mm 175kVAR 7000A 00A 00A 00A 00A 00A 00A C to +55 C x0 / 1x00 x 50mm x 5mm 50 kvar ** C to + 55 C x 50mm x 5mm x 50mm x 5mm 00 kvar ** 0 0 C to + 55 C x 0mm x 5mm , 15, , 15, , 15, , 15, , 15, , ,

7 Technical Data Thermal Overload Relay MNX R MNX R MNX R5 MNX R5L Catalogue Nos. CS909 CS9 CS98 CS90 CS9 CS97 CS99 CS9 CS9 CS91 Range Mounting Direct Direct Separate Separate Separate Separate Suitable for Contactors MNX 9, 1,18 MNX 5, 50, 70 MNX 185, 5, 5, 5,, 0 80, 95,, 5, 00, 550 Rated Insulation Voltage Ui 90V 90V 90V 90V Rated Impulse Voltage Uimp kv kv kv kv Service Temp. o 5 C TO 55 C o 5 C TO 55 C o 5 C TO 55 C o 5 C TO 55 C Start / Off / Reset 1 Start & Off / Reset Builtin Contacts NO + 1 NC NO + 1 NC NO + 1 NC NO + 1 NC Rated Operational V A A A A Current for V 5A 5A 5A 5A AC15 utilisation 0 V A A A A Category at 50Hz 80 / 15V 500 V Trip Class 0 Max. frequency of operations Cycles / hr Main Terminal Capacity Lug (mm ) Aux. Terminal Capacity Wires (mm ) Note All relays are Ambient Temperature Compensated

8 Overall Dimensions FrameIII FrameIV Terminal Screws M5 for MNX 5 / 50 M for MNX 70 / 80 Note: Dimensions of Contactors Not Suitable for Din Rail Mounting Screw M8 x 5 0V A.5 Contactors MNX 5/50 MNX 70/80 Dia A V 1 Holes Ø For Mounting Mounting Holes for M5 Screws 1L1 L 5L 85 Mounting MNX 5 T1 T T Mounting 89, ( NO + NC), ( NO + NC) Mounting Holes for M5 Screws 9 9 MNX5/50 MNX70/ V 1L1 L A1 5L 5 15 T1 A T T 0V 17 () (NO + NC) Printed text of Addon Blocks & Top Cover should be Upright when Oblong Mounting Holes On Rear Housing are at Botto, MNX95 MNX MNX FrameV 1coil Terminal Level 0No Level 7No Level FrameI FrameII M.5 x 9 Cross Screws Mounting Holes to Suit M Screws MNX9 MNX1 MNX18 M x.5 Screws M.5 x 9 Screws Mounting Holes to Suit M Screws MNX5 MNX MNX0 FrameVI M x 0 0V Screw M1 x Mounting Holes for M8 Screws 5 0V 1L1 L 5L L T L 0V Mounting 17 (for ) 171(for NO=NC) MNX185 MNX () 5(NO + NC) MNX5 MNX5 MNX00 MNX550 MNX50 15 Mounting Mounting Holes for M Screw 75 * All dimensions are in mm # Dimension for din rail mounting type available on request.

9 Overall Dimensions MNX R Relay MNX R Relay MNX R5 / 5L Relay * All Dimensions are in mm

10 Accessories & Spares Contactor Type Aux. Add on Block Mechanical Interlock Kit Surge Suppressor Spare Coil Spare kit Frame 1 NO CS9 MNX 9 MNX 1 MNX 18 Frame MNX 5 MNX MNX 0 NO + 1 NC NO + NC 1 NO + NC NC NO 1 NO + 1 NC NC 1 NO CS9 CS9 CS95 CS9 CS97 CS98 CS99 CS9 CS91 CS91 CS95 MNX 9 MNX 1 MNX 18 MNX 5 MNX MNX 0 CS91 CS91 CS915 CS917 CS918 CS917 1 NC CS911 Frame MNX 5 MNX 50 MNX 70 MNX 80 First Left First Right Second Left Second Right CS901 CS90 CS90 CS90 CS9197 CS91 CS919 MNX 5 MNX 50 MNX 70 MNX 80 CS919 CS9 CS9151 CS915 Frame MNX 95 MNX 95 CS915 MNX CS9198 CS91 CS919 MNX CS915 MNX CS905 MNX CS9155 CS90 Frame 5 MNX 185 MNX 5 First Left First Right Second Left CS907 CS908 CS9199 CS91 CS919 MNX 185 MNX 5 CS915 CS9157 Second Right Frame MNX 5 MNX 5 CS9159 MNX 5 CS900 CS915 CS9195 MNX 5 CS9 MNX 00 MNX 00 CS9 MNX 550 Builtin CS919 MNX 550 CS91 MNX 50 MNX 50 CS9 Electrical Standard Products Larsen & Toubro Limited Powai Campus, Mumbai 07 Customer Interaction Center (CIC) BSNL / MTNL (toll free) : Reliance (toll free) : Tel : Fax : cic@lntebg.com Website : SP5079 R 009

Motor Protection Circuit Breakers

Motor Protection Circuit Breakers Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field

More information

NEW. Moulded Case Circuit Breakers New DU Series 20 A to 250 A

NEW. Moulded Case Circuit Breakers New DU Series 20 A to 250 A NEW Moulded Case Circuit Breakers New DU Series 0 A to 50 A About us Larsen & Toubro is a technology-driven USD 7 billion company that infuses engineering with imagination. The Company offers a wide range

More information

About us. Switchgear Factory, Mumbai

About us. Switchgear Factory, Mumbai Wires & Cables About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering,

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

ML 1.5 SS91851 ML 2 SS A 25 A 40 A 13.5 A 17 A 37 A 37 A. 6.3 A 15.5 A 15.5 A 12.5 A 23 A 23 A 19 A 830 V 415 V 500 V 3 kvar 120 A

ML 1.5 SS91851 ML 2 SS A 25 A 40 A 13.5 A 17 A 37 A 37 A. 6.3 A 15.5 A 15.5 A 12.5 A 23 A 23 A 19 A 830 V 415 V 500 V 3 kvar 120 A ML Series Contactor & Thermal Overload Relay Technical Data Type Cat. No. Conformance Standards No.of poles Thermal rating / Utilization category AC-1 :, 415V, 50Hz* Insulation voltage, U (V) I) Stator

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Energy Saving HRC Fuse-Links

Energy Saving HRC Fuse-Links Energy Saving HRC Fuse-Links Cylindrical, Bolted & Blade Type About us Larsen & Toubro infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering,

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Moulded Case Circuit Breakers New DU Series 20 A to 250 A

Moulded Case Circuit Breakers New DU Series 20 A to 250 A NEW Moulded Case Circuit Breakers New DU Series 0 A to 50 A About us Larsen & Toubro is a technology-driven USD 7 billion company that infuses engineering with imagination. The Company offers a wide range

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays New generation of Contactors from LS Industrial Systems Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol

More information

Energy Saving HRC Fuse-Links

Energy Saving HRC Fuse-Links Energy Saving HRC Fuse-Links Cylindrical, Bolted & Blade Type About us Larsen & Toubro is a technology-driven company that infuses engineering with imagination. The Company offers a wide range of advanced

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Controls. CONTACTORS CWB Line (up to 40A)

Controls. CONTACTORS CWB Line (up to 40A) Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

Thermal Overload Relays

Thermal Overload Relays Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application s SICOP Bimetal Overload Relays Type 3UA5/6 & 3UC5/6 Introduction The bimetal overload relays type 3UA5/6 & 3UC5/6 relays are indigenously manufactured and bring to the users a whole range of benefits,

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175. SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

B Mini Contactor V Hz

B Mini Contactor V Hz ABB B7-30-10-80 Mini Contactor 220-240V 40-450Hz General Information Extended Product Type Product ID B7-30-10-80 GJL1311001R8100 EAN 4013614150197 Catalog Description Long Description B7-30-10-80 Mini

More information

Capacitor Switching Contactors Type K3...-A, K3...-K

Capacitor Switching Contactors Type K3...-A, K3...-K Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and

More information

Bimetal Overload Relays 3UA and 3UC

Bimetal Overload Relays 3UA and 3UC 32 Bimetal Overload Relays 3UA and 3UC The 3UA / 3UC thermal overload relays are suitable for customers from all industries, who want guaranteed optimum inverse time delayed protection of their electrical

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

BC Mini Contactor VDC

BC Mini Contactor VDC ABB Mini Contactor 110-125VDC General Information Extended Product Type Product ID GJL1213001R0014 EAN 4013614052859 Catalog Description Long Description Mini Contactor 110-125VDC The BC6-30-01 mini contactor

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Features. Applications. Commercial Industrial Mining. New CBI range additional to existing range DILM7 SN10 DILM9 SN11 DILM12

Features. Applications. Commercial Industrial Mining. New CBI range additional to existing range DILM7 SN10 DILM9 SN11 DILM12 GLOBAL RANGE Global Range Thermal Contactors Contactors Contactor Product Comparison Features Competitively priced Comprehensive range (AC & DC) Fitted with Auxiliary/s as standard Type coordination Applications

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Series CA5 Contactors

Series CA5 Contactors Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower

More information

Low Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays

Low Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays CWB and RW27-2D IEC Contactors and Thermal Overload Contactors Overload A-2-800-ASK4WEG www.weg.net/us Contactors CWB CWB Features A-4 Catalog Number Format A-7 Accessories Overview A-8 Part Number List

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC Product data sheet Characteristics LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88. Motor Starters Star-Delta Starters Open Type 86 Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88 Accessories 89 Reversing Contactors 90 Pole Changing Starters 92 Technical Data 94 Wiring

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers L&T SWITCHGER S F E & S U R E imp: k U 8 V Ue V, 60Hz. :4 0/ Ic u : 70k, I :0%I C T: cs cu D2 S IS 3947-2 IEC 60947-2 E 60947-2 - Moulded Case Circuit Breakers bout us Larsen & Toubro is a technology-driven

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com TeSys D, K Catalogue 2017 'S335' series contactors for electrodomestic applications schneider-electric.com Presentation TeSys D, TeSys K TeSys D, TeSys K: S335 series Best-in-class contactors for electrodomestic

More information

ABB s new control and protection devices

ABB s new control and protection devices ABB s new control and protection devices One product family ABB presents a new generation of first-class specialized components: manual motor starters, contactors, overload relays and softstarters for

More information

Manual Motor Starters

Manual Motor Starters Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC

More information

Contactors and Overload Relays

Contactors and Overload Relays Contactors and Overload Relays Catalogue 2011 2 CONTENT Contactor Introduction...4 Range over view...8 Technical information - CN Series...10 Add on accessories - CN Series...12 Accessory fitment over

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics LC1F400E7 Complementary [Uimp] rated impulse withstand voltage Overvoltage category [Ith] conventional free air thermal current Main Range Product name Product or component

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

Submittal Data Information

Submittal Data Information Effective: NOVEMBER 3, 2014 JOB CONTRACTOR ITEM NO. Submittal Data Information TDX - Taco Duplex Starter ENGINEER REP. 301-2693 Supersedes: NEW TDX - TACO DUPLEX STARTER 1Ø, 230V, 1/10-15HP 3Ø, 200-460V,

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Motor Starting Solutions Open Type Version, in Kit Form

Motor Starting Solutions Open Type Version, in Kit Form Motor Starting Solutions Open Version, in Kit Form Starters Protected by Manual Motor Starters Direct-On-Line Starters I> Reversing Starters I> MS... Manual motor starter MS... Manual motor starter BEA...

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

22AF 40AF AF 150AF 225AF 400AF 800AF

22AF 40AF AF 150AF 225AF 400AF 800AF Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug

More information

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015 Low Voltage EasyPact TVS Motor starters from 6A to 630A Catalog 2015 Designed for the essential EasyPact TVS General contents EasyPact TVS contactors, 6 A to 630 A A-1 EasyPact TVS thermal overload relays

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

JOSLYN CLARK VACUUM CONTACTORS

JOSLYN CLARK VACUUM CONTACTORS COLTERLEC ELECTRICAL ENGINEERING PRODUCTS SECTION JOSLYN CLARK VACUUM CONTACTORS COLTERLEC ELECTRICAL ENGINEERING PRODUCTS 339 TM CONTENTS Joslyn Clark - New 300Amp, 1140 Volt Heavy Duty Mining Vacuum

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

FUJI Magnetic Contactors and Motor Starters

FUJI Magnetic Contactors and Motor Starters FUJI Magnetic Contactors and Motor Starters Technical Information AEH28a CONTENTS Chapter Contactors and Starters - International standards... 4-2 Ratings and specifications... 8-3 Performance and characteristics...

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC Product datasheet Characteristics LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 -

More information

Motor Protection Circuit Breaker

Motor Protection Circuit Breaker Motor Protection Circuit Breaker Catalogue 2011 CONTENT Introduction...4 Features...4 Parts Identification...5 Technical information (MPCB)...5 Technical information (Aux. contact, Fault signalling contact)...6

More information

Overview. Contents. Overview

Overview. Contents. Overview 1/0 Overview 1 Contents Overview 3-pole Block Contactors and Motor Protection... 1/ 4-pole Block Contactors... 1/3 Contactors for Specific Applications... 1/4 Mini Contactors and Motor Protection... 1/

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Contactor Relays 3TH30

Contactor Relays 3TH30 Contactor Relays 3TH30 Reliability and safety are pre-requisites in the choice of the control contactor. Siemens 3TH30 contactor relays satisfy these criteria and thus offer the right choice to the customer.

More information

About us. Switchgear Factory, Mumbai

About us. Switchgear Factory, Mumbai LTXL Capacitors LTXL Capacitors About us Larsen & Toubro is a technology-driven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

Bulletin 193-T1 Bimetallic Overload Relays

Bulletin 193-T1 Bimetallic Overload Relays Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode

More information

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC Product datasheet Characteristics LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Motor Protection Circuit Breakers 3VU13 and 3VU16

Motor Protection Circuit Breakers 3VU13 and 3VU16 Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection

More information