DETAIL 'A' INTERIOR INSTALLATION. OVERALL ISOMETRIC VIEW (unless noted otherwise) 300C CARRIER 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS
|
|
- Moris Miles
- 5 years ago
- Views:
Transcription
1 3 " NOM. 316 G, ER V RO N HA. TYP SEE DETAILS A1.7 THROUGH A1.10 FOR FIXTURE OPENING RECOMMENDATIONS IE ARR XC 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL A1.2 A "M 1'-0 300C PANEL SPLICE SEE DETAIL A C SYSTEM PROFILE 13" NOM TYPICAL SYSTEM SECTION SEE DETAIL THIS SHEET DETAIL AX "M 4'-0 GER N HA E WIR P., TY G CIN SPA 300C PANEL SEE DETAIL A1.1 WALL ANGLE SEE DETAIL A1.5 WALL ANGLE SEE DETAIL A1.5 4'-0 "M SPA CIN G, TY P '-0 0C " M PAN IN - EL 19' LENG -8" TH MA X 0 11 C P -1 AN 3/ E 16 L W "N I OM DTH. IER FLOATING TRIM SEE DETAIL A1.6 TRIM NOT SHOWN FOR CLARITY 30 PANEL BUTT JOINT SEE DETAIL A1.4 AX CAR R PAN SUSPENSION REQUIREMENTS SEE DETAIL A1.2 "M -0 2' EL O VER AX HA N G, T YP. INTERIOR INSTALLATION All rights reserved. T his dr awing is the pr oper ty of H unt er Dougl as. I t may not be copi ed or mult i pl i ed, nei t her no t b e su bmi t t e d f o r per usal to thir d par ties. OVERALL ISOMETRIC VIEW PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.0
2 " NOM. SYSTEM HEIGHT " PANEL HEIGHT " PANEL HEIGHT PERFORATION #160 AT FACTORY PANEL END 3'-0" MINIMUM PANEL LENGTH 19'-8" MAXIMUM PANEL LENGTH** " (11.81) PANEL WIDTH ONLY NON-PERFORATED FACTORY PANEL END FACTORY PANEL SIDE VIEW *VERTICAL SUPPORT OMITTED FOR CLARITY **PANEL LENGTHS VARIABLE IN 1/8" INCREMENTS, TOLERANCE ±1/8" FACTORY PANEL ENDS *SUSPENSION OMITTED FOR CLARITY " (11.81) PANEL WIDTH 300C PANEL MATERIAL THICKNESS.028" ALUMINUM 300C PANEL FINISHES PAINTED & POWDER COATED PERFORATION DIRECTION DECORATED WOOD FINISH (POWDER COATED) WOOD VENEER PERFORATION #160 PERF AREA 23% OPEN HOLE DIAMETER 0.060" AVAILABLE PANEL PERFORATION of H unter Dougl as. It not be submi t ted f or PANEL SPEC PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.1 SCALE: NTS DATE: 8/15/16
3 4'-0" MAX HANGER WIRE SPACING, TYP. 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS NOTE: S ARE DIRECTIONAL, CHECK ORIENTATION PRIOR TO INSTALLATION SIDE VIEW OF WITH PANEL 1'-0" MAX CARRIER OVERHANG, TYP. SIDE VIEW OF END VIEW OF WITH PANEL 300C PANEL 4'-0" MAX CARRIER SPACING, TYP. END VIEW OF 2'-0" MAX PANEL OVERHANG, TYP. MATERIAL: FINISH: PART LENGTH:.040" ALUMINUM MATTE BLACK 16'-0" of Hunter Douglas. It not be submitted f or SUSPENSION SPEC PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.2 SCALE: NTS
4 12" MAXIMUM AT CARRIER SPLICE 12" MAXIMUM AT CARRIER SPLICE CARRIER SPLICE 12 GA HANGER WIRE, NOT BY HUNTER DOUGLAS 12"MAXIMUM AT CARRIER SPLICE 300C PANEL " NOM. 12"MAXIMUM AT CARRIER SPLICE 12 GA HANGER WIRE, NOT BY HUNTER DOUGLAS SECTION - SNAP SPLICE TABS INTO 300C CARRIER IF THE DESIRED CARRIER LENGTH EXCEEDS THE MAXIMUM OF 16'-0", USE A LUXALON CARRIER SPLICE, TO CONNECT TWO FACTORY CARRIER ENDS. THE TABS OF THE SPLICE SNAP INTO THE HOLES IN THE CARRIER AND ADDITIONAL FIXING IS NOT NECESSARY. THE MODULE IS CONTINUED AUTOMATICALLY. INTERIOR INSTALLATION of H unter Douglas. It CARRIER SPLICE PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.3 DATE: 8/15/16
5 4'-0" MAX CARRIER SPACING, TYP. 12 GA HANGER WIRE BY OTHERS, TYP. 24" MAXIMUM PANEL OVERHANG 24" MAXIMUM PANEL OVERHANG 300C PANEL DO NOT FASTEN PANEL ENDS TOGETHER. DOING SO WILL CAUSE DEFORMATION IN PANEL FACE. INTERIOR INSTALLATION ISOMETRIC VIEW OF FACTORY PANEL ENDS AT JOINT *CARRIERS NOT SHOWN FOR CLARITY NOTE: 300C PANEL ENDS MUST BUTT AT FACTORY PANEL ENDS AND PANELS CANNOT BE SPLICED. PANEL ENDS CAN ONLY BE FIELD CUT AT PERIMETERS WHERE TRIMS ARE USED FOR TERMINATIONS. PANEL SPLICES ARE NOT REQUIRED NOR AVAILABLE. of H unter Douglas. It PANEL BUTT JOINT PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.4
6 FIELD MITER TRIMS AT CORNERS SUSPENSION NOT SHOWN FOR CLARITY FIELD CUT 300C PANEL ENDS FOR LENGTH FIELD CUT 300C PANEL SIDES FOR WIDTH USE WALL ANGLE AS HOLD DOWN CLIP FIELD CUT 300C PANEL SIDE SECTION VIEW AT WALL ANGLE & 300C PANEL SIDE USE WALL ANGLE TO SECURE CUT PANEL SIDE. TYPICALLY NOT REQUIRED AT FIELD CUT PANEL ENDS. FACTORY PANEL ENDS DIRECT FASTEN WALL ANGLE TO STRUCTURE WALL ANGLE WALL ANGLE 12'-0" PART LENGTH FACTORY PANEL ENDS INTERIOR INSTALLATION *VERTICAL SUPPORT OMITTED FOR CLARITY of H unter Dougl as. It may not be copi ed or m u l t i p l i e d, ne i t h e r not be submi t ted f or WALL ANGLE TRIM PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.5 SCALE: NTS DATE: 8/15/16
7 2-1/4" " 3-3/16" 12 GA HANGER WIRE, NOTCH TRIM AS NECESSARY, TYP. FIELD CUT 300C PANEL ENDS FIELD MITER TRIMS AT CORNERS FASTENERS TO SECURE 300C J-TRIM TO CARRIER BY OTHERS, TYP. FIELD CUT 300C PANEL SIDES FOR WIDTH FIELD CUT PANEL SIDE USE TRIM ANGLE AS HOLD DOWN " DOUBLE-SIDED ADHESIVE TO SECURE TRIM ANGLE FIELD CUT PANEL END SECTION SCALE: 6" = 1'-0" SECTION SCALE: 6" = 1'-0" WALL ANGLE TO SECURE FIELD CUT PANEL SIDE. TYPICALLY NOT REQUIRED AT FIELD CUT PANEL ENDS & FULL PANEL EDGES. 2-1/4" 3-3/16" 300C J-TRIM FOR FLOATING CONDITION 10'-0" PART LENGTH FULL 300C PANELS INTERIOR INSTALLATION *VERTICAL SUPPORT OMITTED FOR CLARITY of H unter Dougl as. It m ul t i p l i e d, n e i t h er not be submi t ted f or FLOATING TRIM PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.6 SCALE: NTS DATE: 8/15/16
8 MAX LENGTH VARIES BASED ON PANEL LENGTH INTERRUPT CARRIER AT FIXTURE LOCATION, TYP. 2" MIN FROM PANEL END, TYP. ROUND OPENINGS FOR CAN LIGHTS, SPEAKERS, SPRINKLERS, ETC. 8" MAX WIDTH CENTERED IN PANEL RECOMMENDED MAX VARIES BASED ON PANEL LENGTH 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. 300C PANEL FIELD CUT FOR FIXTURE OPENING 2" MIN FROM PANEL END, TYP. RECOMMENDED 8" MAX WIDTH FOR FIELD CUT OPENING CENTERED IN PANEL INTERRUPT CARRIER AT FIXTURE FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS BEYOND FIELD CUT 300C PANEL FIELD CUT 300C PANEL SECTION - SECTION - NOTE: ROUND OPENINGS LESS THAN EIGHT (8) INCHES DIAMETER TYPICALLY FIELD CUT INTO PANEL FACE, TRIM FOR ALL FIXTURES BY OTHERS NOT BY HUNTER DOUGLAS of Hu nter Douglas. It FIELD CUT PANEL FOR FIXTURE OPENINGS PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.7
9 INTERRUPT CARRIER AT FIXTURE LOCATION, TYP. MAX LENGTH VARIES BASED ON PANEL LENGTH VARIES TO ACCOMMODATE FIXTURE WIDTH MAX WIDTH TO REMAIN ON MODULE MAX VARIES BASED ON PANEL LENGTH FACTORY 300C PANELS MAX WIDTH TO REMAIN ON MODULE INTERRUPT CARRIER AT FIXTURE FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS BEYOND FIELD CUT 300C PANEL FULL 300C PANEL FULL 300C PANEL SECTION - SECTION - NOTE: FIXTURE WITH TRIM FLANGE NOT BY HUNTER DOUGLAS of H unter Douglas. It INTERRUPTED PANEL FOR FIXTURE OPENINGS PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.8
10 MAX WIDTH VARIES BASED ON PANEL LENGTH MAX LENGTH VARIES 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. 2" MIN FROM PANEL SIDE, TYP. 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. MAX WIDTH VARIES BASED ON PANEL LENGTH FIXTURE CUT IN 300C PANEL FACE MAX WIDTH VARIES 2" MIN FROM PANEL SIDE, TYP. 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. CONTINUOUS 300C CARRIER BEYOND FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIELD CUT 300C PANEL FIELD CUT 300C PANEL SECTION - SECTION - NOTE: ROUND OPENINGS LESS THAN EIGHT (8) INCHES DIAMETER TYPICALLY FIELD CUT INTO PANEL FACE, TRIM FOR ALL FIXTURES BY OTHERS NOT BY HUNTER DOUGLAS of Hu nter Douglas. It FIELD CUT PANEL FOR FIXTURE OPENINGS PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.9
11 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. MAX WIDTH VARIES PANEL LENGTHS FACTORY FABRICATED TO MAINTAIN PANEL SEAM MODULE MAX LENGTH VARIES BASED (PANEL WIDTH) ON INCREMENTS FACTORY FULL 300C PANELS 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. MAX WIDTH VARIES BASED ON INCREMENTS (PANEL WIDTH) OPENING WIDTH VARIES 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. CONTINUOUS 300C CARRIER BEYOND FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FULL 300C PANEL FULL 300C PANEL SECTION - SECTION - NOTE: FIXTURE WITH TRIM FLANGE NOT BY HUNTER DOUGLAS of H unter Douglas. It INTERRUPTED PANEL FOR FIXTURE OPENINGS PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.10
12 COMPRESSION STRUT SPLAYED 12 GA HANGER WIRE, BY OTHERS, TYP N E W S 300C PANEL LATERAL BRACING: BRACE WITH HANGER WIRES AND STRUTS PER ASTM E-580 AND IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. (4) #12 GAUGE WIRES SPLAYED 90 FROM EACH OTHER AT ANGLE NOT EXCEEDING 45 FROM PLANE OF CEILING. A STRUT FASTENED TO MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO STRUCTURE ABOVE. SPLAYED WIRE AND STRUT BRACING TO BE PLACED NOT MORE THAN 12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 6 FEET FROM EACH WALL. INTERIOR INSTALLATION of H unter Douglas. It SEISMIC SPEC PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.11 SCALE: NTS DATE: 8/15/16
INTERIOR INSTALLATION
HOOK ON CROSS CONNECTOR CLAMP AT ALL INTERSECTIONS OF S 4-1 4" PANEL 1/2" x 1-1/2" 16 GA CR CHANNEL PRIMARY AT 48" O.C. MAX SPACING, TYPICAL. PANEL 1 1 2 " 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS.
More information12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL A1.1 MAIN RUNNER SPLICE. SPECIFICATIONS (unless noted otherwise)
12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL A1.1 4' OPEN CELL RUNNER SEE DETAIL A1.7 FOR INFILL PANEL FIXTURE OPENING RECOMMENDATIONS CROSS RUNNER FIELD CUT AT PERIMETER TYPICAL SYSTEM
More informationMIDDLE SECTION REPRESENTS "BLADE SIZE" (EXAMPLE: 24 = 24/32" [3/4"] 48 = 48/32" [1 1/2"]) REPRESENTS NUMBER OF BLADES PER 12" WIDE PANEL WG WB
HOW TO READ PRODUCT "SKU" : FIRST TWO LETTERS REPRESENT "PRODUCT TYPE" MIDDLE SECTION REPRESENTS "BLADE SIZE" (EXAMPLE: 24 = 24/32" [3/4"] 48 = 48/32" [1 1/2"]) REPRESENTS NUMBER OF BLADES PER 12" WIDE
More informationPANEL SPLICE SEE DETAIL A1.3 FLOATING TRIM SEE DETAIL A1.7 TRIM NOT SHOWN FOR CLARITY
V-7 CAIE 4" MODULE OPTIONAL FLUSH CLOSUE OPTIONAL ECESSED CLOSUE 21 32 " 3 11 32 " 1 1 8 " 5 8 " 1 29 32 " 12 GA HANGE WIE, BY OTHES, NOT BY HUNTE DOUGLAS SEE DETAIL A1.2 TYPICAL SECTION SUSPENSION EQUIEMENTS
More informationSafeLite Installation Steps For a 2 x 2 Light Fixture
SafeLite Installation Steps For a 2 x 2 Light Fixture SafeLite Installation Instructions Fluorescent Fixtures (Refer to Diagrams) 1) For existing ceiling applications, remove ceiling tile from both sides
More information2006 Saturn Ion ACCESSORIES & EQUIPMENT Doors - Ion
POWER DOOR LOCK SWITCH REPLACEMENT Removal Procedure Fig. 28: View Of Power Door Lock Switch 1. Using a flat-bladed tool, pry the switch from the door trim panel enough to expose the locking tabs. 2. Press
More informationSECTION METAL LOCKERS. A. ADAAG - Americans with Disabilities Act, Accessibility Guidelines.
Section 10_51_13_MetalLockerPenco-ProTough_8-19-09 PART 1 GENERAL SECTION 10 51 13 METAL LOCKERS 1.01 SECTION INCLUDES A. Heavy Duty Welded Tubular Frame Lockers. B. Locker benches. 1.02 REFERENCES A.
More informationCLEANROOM PRODUCTS FLUSH HEPA GRID WITH INTEGRAL LIGHTING PLENUM MODULES CUSTOM AIR HANDLERS PLENUM MODULES FAN POWERED PLENUM MODULES
TOP LOAD FLUSH GRID BOTTOM LOAD FLUSH GRID FLUSH HEPA GRID WITH INTEGRAL LIGHTING TOP LOAD FLUSH HEPA CEILING GRID BOTTOM LOAD FLUSH HEP CEILING GRID 34 & 316 BOTTOM LOAD FLUSH PLENUM MODULES PLENUM MODULES
More informationGRAVITY VENTILATORS SIZING
GRAVITY VENTILATORS SIZING RCXII (sizes 6-20) RCXII (sizes 24-36) RCXII-SF BGH RLX Sizing The tables shown offer quick selections at common static pressure points. Selection choices vary widely due to
More informationCUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER
ARCHITECTURAL SLOT DIFFUSER Custom Flow (CF) slot diffusers are uniquely designed for curving and long continuous installations. The CF offers a large range of airflow flexibility with one or two slot
More information20" 1/1/14 Drawn By: Plan. R Custom 3 4 " " Title: S.S Brake-metal corner. View: Detail System Type: Scale:
1" 3 4 " 20" 3 4 " 15 16 " S.S Brake-metal corner Plan R Custom Full WPS, Inc 1 8 " Panel Clip (GEN-017) Edge Trim (SHA-101) Bottom Edge Detail Section A Shadowline System Full WPS, Inc Variable inside
More informationAEROWINGS Sun Control Systems
AEROWINGS 200-400 wwwluxaloncom Sun Control Systems Luxalon Aerowings 200-400 System Description Luxalon wing-shaped elements, or fins, combine optimum solar effectiveness with an elegant and futuristic
More informationNo clips required for this panel system
ROOFING S SERIES 1000, 1100 & 1101 ABOUT SPACING... This guide is intended to provide you with sufficient information so that you may choose the appropriate clip for our metal roof system. We have purposely
More informationSECTION METAL LOCKERS. A. ADAAG Americans with Disabilities Act, Accessibility Guidelines.
SECTION 10 51 13 METAL LOCKERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Heavy Duty Welded Gear Lockers. B. Locker benches. 1.02 REFERENCES A. ADAAG Americans with Disabilities Act, Accessibility Guidelines.
More informationCOMPACT BUSWAY 40 & 60 AMP HOUSING
40 & 60 AMP HOUSING B40 & HOUSING Each Track Busway housing section consists of an extruded aluminum housing with an insulated strip containing copper conductors mounted on the top interior wall. The aluminum
More informationSection 3. Custom. Recessed
Section 3 Custom Recessed BX Connector 13.375" 11.375" Hanging Cable Typ (By others) Threaded Rod Typ (By others) 23.375" OAL Fixture Lamp Housing PAR30 Lamp Holder Ballast Compartment 6.781" 45 " 12.000"
More informationSLIDING DOOR SYSTEM_ S42 TECHNICAL BOOK. System description Accessories
SLIDING DOOR SYSTEM_ S42 TECHNICAL BOOK System description Accessories 1 SLIDING DOOR SYSTEM_ S42 1.0_ System description, Sliding panel_ page 03 2.0_ Profiles_ page 04 3.0_ System description, Fixed panels_
More information1501 Industrial Way N., Toms River, NJ Fax: PACKING LIST MUSTANG GT LONG TUBE HEADERS (M30000)
ADVANCED - Installation requires professional-type tools and advanced automotive-service skills. If you lack experience with internal engine modifications, an Advanced installation is probably beyond your
More informationShort-throw Shifter Installation Guide
Short-throw Shifter Installation Guide Removal Procedure 1) Remove the shift control knob. A. Lift up on the rear portion of the shift control closeout boot retaining ring and detach the retaining ring
More informationCEILING MOUNTED WORK STATION STEEL BRIDGE CRANE
SECTION 14636 CEILING MOUNTED WORK STATION STEEL BRIDGE CRANE ***** Gorbel, Inc. manufactures a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work
More informationHSpecialties Inc. TABLE OF CONTENTS
TABLE OF CONTENTS Introduction... Curtain Track Selection Guide...2 Ordering COMPLETE Tracks...3 00 Series Standard-Duty Straight Track...4 200 Series Black Medium-Duty Straight Track...8 300 Series Standard-Duty
More informationNotes: 2 3/8" 60mm. (1) One lamp with satin lens only (2) Not available for T8 Add 9 per lamp. Specify quantity Requires 120V or 277V
PROJECT INFORMATION Project: Notes: Type: DIMENSIONS SECTION VIEWS 2 3/8" 60mm ORDERING CODE 9 3/4 248mm 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 PRODUCT SPECIFICATIONS 1 PRODUCT ID 2 OPTICS 3 LENGTH/FT
More information2-120-T Aurora BRO FEATURES
2-120-T Aurora BRO FEATURES A R TY T LIMI ED WA R R A N SEMBLED AS CANAD A IN Utilizes Bridgelux LED Lumen output: 800 3000 20 aiming (3 series) Die-cast aluminum fixture Powder coated and plated trim
More information1. Product Overview: Read all instructions for installing Drop-In Panels before starting.
1. Product Overview: Read all instructions for installing Drop-In Panels before starting. Kinetics Drop-In Panels are an out of the box, plug and play acoustic panel, with the fiberoptic star ceiling experience
More informationL10 - L40: 6-5/8 L50 - L60: 7-3/ K K K K. EM/10W 10-watt emergency battery [4] TrimLock.
CATALOG #: - : 6-5/8 - : 7-3/8 TYPE: ø6 ø7 PROJECT: FEATURES Williams TrimLock reflector retention system eliminates trim sag Beam angles ranging from 1 narrow to 65º wide for tailored performance Open
More informationINSTALLATION INSTRUCTION W Track Recessed 120V Flangeless
W Track Recessed 120V Flangeless WT4-RTL, WT8-RTL, WT12-RTL SAFETY INSTRUCTION Read all of these instructions before installing the track system. Turn off power at main switch before installing or modifying
More informationRunning Magnet 2.0 Recessed High-tech LED lighting system for interior architecture
Description Fun with magnets and light. Simultaneously graphic and subtle, the Running Magnet is flexible, precise, and as creative as you. It is track lighting redesigned and elegantly refined. Light
More information6DR 6 Downlight Round
- : 6-5/8 : 7-3/8 CATALOG #: ø6 ø7 TYPE: PROJECT: NEW CONSTRUCTION AND REMODEL FEATURES Innovative TrimLock reflector retention system ensures trim remains flush with ceiling plane Dim to warm from 1800K
More informationREVISION DESCRIPTION:
REVISION DESCRIPTION: 14401 Keil Road NE, Aurora, Oregon, USA 97002 PHONE 503-678-6545 FAX 503-678-6560 www.vansaircraft.com info@vansaircraft.com Service Letters and Bulletins: www.vansaircraft.com/public/service.htm
More informationLUXLINEAR LOW 1707 SLEEKER ILLUMINATION MECHANICAL. Indoor/Dry Location Series
SLEEKER ILLUMINATION Our LUXLINEAR Low Profile 1707 LED light tubes is specially designed to fit into and illuminate slimmer, compact fixtures and applications. The profile s shorter height provides a
More informationP15 - P44: 5-3/4 P62: 6-1/2. SCA Sloped ceiling TrimLock K K K K TW Tunable white (80 CRI, 2700K 5000K) 65 Open
CATALOG #: - : 5-3/4 : 6-1/2 TYPE: ø4-1/2 ø5-1/2 PROJECT: NEW CONSTRUCTION AND REMODEL FEATURES Williams TrimLock reflector retention system eliminates trim sag Williams turn-key Power over Ethernet (PoE)
More information2-520-T Miro BRO FEATURES
2-520-T Miro BRO FEATURES A R TY T LIMI ED WA R R A N SEMBLED AS CANAD A IN Utilizes Bridgelux LED Lumen output: 800 3000 20 aiming (3 series) Clear glass lens standard Die-cast aluminum fixture Powder
More informationISO 9001:2008
DOOR Dutch, Standard Duty, Individual Dog Model Features 1 FREEMAN MARINE Dutch doors perform like a single panel door when regular access is needed, yet the top half can be operated separately from the
More information2-115-T Aqua BRO FEATURES
2-115-T Aqua BRO FEATURES A R TY T LIMI ED WA R R A N SEMBLED AS CANAD A IN Utilizes Bridgelux LED Lumen output: 800 3000 Wet location listed 20 aiming (3 series) Die-cast aluminum fixture Powder coated
More informationOWAtecta. OWA metal ceilings. OWAtecta Metal ceilings
OWAtecta OWA metal ceilings OWAtecta Metal ceilings 3 OWAtecta Metal ceilings Contents Inhalt Perforations steel... 4 Perforations aluminium... Systems System S b OWAline... 7 System S 6M Tube Ceiling....
More informationSafety Grating DIAMOND-GRIP PRODUCT DESCRIPTION FEATURES & BENEFITS MATERIAL SPECIFICATIONS. Note:
DIAMOND-GRIP PRODUCT DESCRIPTION Diamond-Grip is a one-piece metal plank grating manufactured by a cold forming process in the shape of a channel. The web of the channel is the walking surface and has
More informationNOTES: REQUIRES REMOTE DRIVER(S) (see page 4 for more info) LED DRIVE POWER DIRECT INDIRECT* VLO
PROJECT NAME: Carbon 2-3/4 1-3/4 EXTRUDED ALUMINUM USING MACHINED END CAPS PREMIUM LEDS WITH VARIOUS COR TEMPERATURES AND LIGHT OUTPUT FT GW FROSTED LENS TYPE: CABLE SUSPENDED (CS) FEATURES: Powered Suspension
More informationNIOB-2 2" BWF IOLITE TRIMS
NIOB-2 2" BWF IOLITE TRIMS New Construction or Remodel Housing Required Source: LED, 14 Watts, 8 Lumens Nora Lighting s 2" Iolite BWF trims are small aperture downlights that can be specified for use in
More informationPC-125x Counter-Balanced Backdraft Damper
PC-15x Counter-Balanced Backdraft Damper Product Bulletin Code No. LIT-101180 Issued April 7, 015 Refer to the QuickLIT Web site for the most up-to-date version of this document. Since 1885, Johnson Controls
More informationR & S Manufacturing and Sales Company
R & S Manufacturing and Sales Company KNOCKED DOWN RIDGE VENTS RV9-12 ASSEMBLY INSTRUCTIONS April 2013 PARTS LIST End Caps (2 per vent) Wind Bands (2 per vent) Skirt Flashings (2 per vent) Skirt Cross
More information600 SERIES STANDARD DUTY STRAIGHT TRACK INSTALLATION INSTRUCTIONS
600 SERIES STANDARD DUTY STRAIGHT TRACK INSTALLATION INSTRUCTIONS PLEASE READ INSTRUCTIONS THOROUGHLY BEFORE BEGINNING. A. BI-PARTING TRAVEL 1. Before raising track into position, determine location of
More informationSolarSheat Wall Installation Manual
SolarSheat Wall Installation Manual Version 3.2 December 15, 2015 Copyright 2015 Your Solar Home, All Rights Reserved SolarSheat products must be installed in accordance to all local building, plumbing,
More informationHLS House Lighting System SURFACE MOUNT, 2-CIRCUIT REMOTE POWER SUPPLY
PROJECT: TYPE: HLS House Lighting System APPLICATION The House Lighting System (HLS) is designed to illuminate spaces requiring several lighting scenarios, such as theater or auditorium venues. Based on
More informationSERIES 4SQLBV OPEN Lumen Bridgelux LED Recessed Downlight
APPLICATION These high-lumen fixtures are ideally suited for lobbies, auditoriums and many other applications with high ceilings, where superior light output is needed. Multiple beam distributions are
More information400 SERIES STANDARD DUTY STRAIGHT TRACK INSTALLATION INSTRUCTIONS
400 SERIES STANDARD DUTY STRAIGHT TRACK INSTALLATION INSTRUCTIONS PLEASE READ INSTRUCTIONS THOROUGHLY BEFORE BEGINNING. A. BI-PARTING TRAVEL BATTEN INSTALLATION 1. Place track either on the floor or on
More informationSERIES 6VLFL2X Lensed LED Downlight Lumen Flex
APPLICATION Small-aperture medium-distribution downlight is suitable for commercial, retail and institutional applications that require an energy saving, long life LED lamp source, high lumen output, excellent
More information2-125-T Deep Aurora BRO
2-125-T Deep Aurora BRO FEATURES P. 604.464.5644 T. 1.800.464.9544 F. 604.464.0888 TY WA R R A N SEMBLED AS RNIA T FO I LI T N 13 E TL 2-125-T-Deep-Aurora-BRO-Specs Subject to change without notice Rev
More information4DR 4.5 Downlight Round
CATALOG #: - : 5-3/4 : 6-1/2 ø4-1/2 ø5-1/2 TYPE: PROJECT: NEW CONSTRUCTION AND REMODEL FEATURES Williams TrimLock reflector retention system eliminates trim sag Tunable white from 2700K to 5000K CCT, minimum
More informationRunning Magnet 2.0 Surface High-tech LED lighting system for interior architecture
Description Fun with magnets and light. Simultaneously graphic and subtle, the Running Magnet is flexible, precise, and as creative as you. It is track lighting redesigned and elegantly refined. Light
More informationWall/Slot -II 85N Recessed Perimeter
Type: Project: Wall/Slot -II 85N Recessed Perimeter Specifications 10 1/2 (267 ± 19) 9" (229) baffle shown in flush F/position 3 5/8" (92) FIXTURE SUPPORT RAIL. Extruded white aluminum, wall-mounted rail
More informationNAILCLMP-Nail Clamps RW List Prices - Page J-1
NAILCLMP-Nail Clamps RW List Prices - Page J-1 Pipe Clamps With Nail Suspension Clamps 13405618 1/2 556-2 Half Clamp W/Nail 0.36 13405634 3/4 556-3 Half Clamp W/Nail 0.40 13499998 1 556-4 Half Clamp W/Nail
More informationTechnical Data Sheet Signature 841
Technical Data Sheet Signature 841 Signature 800 Series Features & Options Standard Features Manually-operated individual-panel movable partition STC 43 or 47 with gypsum board faces STC 49, 52, 53, or
More information4DR 4.5 Downlight Round
CATALOG #: - : 5-3/4 : 6-1/2 ø4-1/2 ø5-1/2 TYPE: PROJECT: NEW CONSTRUCTION AND REMODEL FEATURES Innovative TrimLock reflector retention system ensures trim remains flush with ceiling plane Dim to warm
More informationENCLOSURES & PANELS. The Trusted Source for Innovative Control Solutions
ENCLOSURES & PANELS The Trusted Source for Innovative Control Solutions 1-717-767-6511 999 This page intentionally left blank. 1000 www.redlion.net MODEL ENC13 - NEMA 4 ENCLOSURES FOR CUB7 This enclosure
More informationGP Lam LVL. Grade Thickness Depth , , , , , 149, 169, 189, 249 (209and 229 by special order) 2.
GP Lam LVL Grade Thickness Depth 2.0E 1 3 49, 3 1 29 7 1 49, 9 1 49, 9 1 29, 11 1 49, 11 7 89, 149, 169, 189, 249 (209and 229 by special order) 1.5E 1 3 49 7 1 49, 9 1 49, 9 1 29, 11 1 49, 11 7 89, 149,
More informationGP Lam LVL. Grade Thickness Depth , 9 1 4, 9 1 2, , , 14, 16, 18, 24 (20 and 22 by special order) 2.
GP Lam LVL GP Lam LVL Introduction.....................32 Bearing Details...................34 Handling and Installation..........35 Floor Beams.....................35 Window, Patio Door and Garage Door
More informationNRM2-511 / NRM2-512 / NRM2-518
HIGH EFFICACY LED LIGHT SOURCE REQUIREMENTS ILLUMINATING THE FUTURE...SINCE 1989 NRM2-511 / NRM2-512 / NRM2-518 5" Marquise II Reflectors Marquise II COB Series enhances an established series of downlighting
More informationREVISION DESCRIPTION: REV 2: Steps re-written for clarity REV 2: Steps re-written for clarity.
REVISION DESCRIPTION: 14-04 REV 2: Steps re-written for clarity. 14-05 REV 2: Steps re-written for clarity. SECTION 14: W-1012-L OUTBOARD W-1012-R TRIMMED OUTBOARD S W-1012-L OUTBOARD W-1025B-R FLAP HINGE
More informationNON-SIZED SIZED HANDED
4040SE SERIES n Standard 4040SE Series closer shipped with a standard arm, 24V or 120V (please specify) SE track, standard plastic clip-on cover, and wood and machine screw pack. SEL tracks are optional,
More informationA. This Section includes the following types of sectional overhead doors:
SECTION 08361 - SECTIONAL OVERHEAD DOORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationA B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver
Page 1 of 13 5E.1 Parts List a. Below Deck Automatic Retractable Security Cover Kit (1) Tube End Bearing Plate (A) (1) Rope Reel with Motor Attached (B) (1) Rope Reel Cover (C) (1) Cover Drum (1) Cover
More informationL10 - L40: 5-3/4 L50 - L60: 6-1/ K K K F OF 1/2. 65 Open. CG Champagne gold anodize for shower. 45 Open
CATALOG #: - : 5-3/4 - : 6-1/2 TYPE: ø4-1/2 ø5-1/2 PROJECT: NEW CONSTRUCTION AND REMODEL FEATURES Williams TrimLock reflector retention system eliminates trim sag Die cast trim choices include flush, regressed
More informationSLIM PENDANT DIRECT. Project. Type. Notes. Ordering Guide PERFORMANCE PER LINEAR FOOT AT 3500K 1 / 8. axislighting.com. Shown with VL optic
Project Type Notes Shown with SO lens Shown with louver Shown with VL optic PERFORMANCE PER LINEAR FOOT AT 35K NOMINAL LUMEN OUTPUT INPUT WATTS EFFICACY DISTRIBUTION UP DOWN 1 3/8" up/1down at 8 lm/ft
More informationAcoustical. Pages Watch for this icon for compatibility with new taller grid profile. Ph:
Watch for this icon for compatibility with new taller grid profile Pages 175-190 Sold by: http://www.twacomm.com Toll Free: (877) 892-2666 175 Lay In And Troffer Light Fixture Support Clips The original
More informationSpecialties Inc. DISCLAIMER TABLE OF CONTENTS
TABLE OF CONTENTS Curtain Track Selection Guide...2 Ordering COMPLETE Tracks...3 Recommended Track Hanger Spacing...4 100 Series Standard-Duty Straight Track...6 200 Series Black Medium-Duty Straight Track...10
More informationOFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1
N Power Box Opening Data Port Openings Rear View Front View Remove opening blanks on raceway cover for power and data. If panel contains no electric or data and is used as a pass-thru, leave opening blanks
More informationL10 - L40: 6-5/8 L50 - L60: 7-3/ K K K F. 65 Open. SPC Clear specular anodize for shower
CATALOG #: - : 6-5/8 - : 7-3/8 TYPE: ø6 ø7 PROJECT: NEW CONSTRUCTION AND REMODEL FEATURES Williams TrimLock reflector retention system eliminates trim sag Industry-leading efficacies as high as 116 lm/w
More information4DS 4.5 Downlight Square
CATALOG #: 4-1/2 5-1/2 TYPE: PROJECT: NEW CONSTRUCTION AND REMODEL FEATURES Tunable white from 2700K to 5000K CCT, minimum 80 CRI 4 inch aperture is unobtrusive in small scale spaces Square shape accentuates
More informationAC-20 Multi Point Actuator
29.6 (1.17) 51.1 (2.01) 29.6 (1.17) 51.1 (2.01) Cable B 52 27.3 (2.05) (.68) 27.3 (.68) 4X Ø 5.2 ± 0.1 (.210 ±.005) Cable A 29.6 (1.17) 17.3 (.68) 80.9 (3.19) 119 (4.7) (1.17) AC-20 Multi Point Actuator
More informationLCN 4040SE SERIES FEATURES HINGE (PULL) SIDE MOUNTING
HINGE (PULL) SIDE MOUNTING Standard 4040SE series closer shipped with a standard arm, 24V or 120V (please specify) SE track, standard plastic clip-on cover, and wood and machine screw pack. SEL tracks
More informationRunning Magnet 2.0 Surface High-tech LED lighting system for interior architecture
RECESSED SURFACE SUSPENSION UP & DOWN Description Fun with magnets and light. Simultaneously graphic and subtle, the Running Magnet is flexible, precise, and as creative as you. It is track lighting redesigned
More informationTubular Daylighting Device with Proven Performance
Tubular Daylighting Device with Proven Performance Collection Reflection Distribution SunPath Tubular Daylighting Device (TDD) Carlisle s SunPath TDD is a perfect complement to the company s SunWeld industrial
More informationOpticom Rack Mount Fiber Enclosures
Opticom Rack Mount Fiber Enclosures Part Numbers: FRME1U, FRME2U Panduit Corp. 2011 INSTALLATION INSTRUCTIONS FRME1U FRME2U Contents - (#) indicates FRME2U quantity 1 - ENCLOSURE 2 - MOUNTING BRACKETS
More informationP RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS
P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS CONTACT INFORMATION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and
More informationMARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits
MARCH 2012 COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before
More informationHCB-8 AFTER BLENDING. Servoreeler vertical cradle support Registration slots in adapter bracket
HCB-8 Hard Ceiling Box 8 Square Access Door Ceiling Box Assembly permits the installation of an SRL-8 Servoreeler above a sheetrock or other permanent ceiling structure. The HCB-8 provides service access
More informationSUBMITTAL SHEET Panel Radiator Model PR
SUBMITTAL SHEET Panel Radiator Model PR CAT-75571 PR-3 with Both Side & Vertical Connections - Shown for Example Only MODEL BTU/Ft/Hr @ LISTED AWT & 65 f EAT TYPE 215 F 190 F 180 F 170 F 160 F 150 F 140
More informationEstimated Cable Fill Width in (mm) in 2 mm 2.30 OD. Cable Fill Area
ONTRAC WIRE MESH CABLE TRAY SYSTEM OnTrac Wire Mesh Cable Tray System CPI s OnTrac Wire Mesh Cable Tray System is an excellent solution for indoor cable pathway applications to create point-to-point pathways
More informationWESTERN SPECIFIER. Technical Data for PWI Joists, PWLVL Headers, Beams, Rim Board, Stud, and Dimension
E N G I N E E R E D W O O D WESTERN SPECIFIER Technical Data for PWI Joists, PWLVL Headers, Beams, Rim Board, Stud, and Dimension P R O D U C T S JOIST DIMENSIONS 9½ LVL FLANGE PWI JOIST SERIES JOIST DIMENSIONS
More informationRittling Econoline Enclosures
Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Rittling Econoline Enclosures Submittal Data, English Language, IP Units Submittal data Project Job number Architect Performance
More information4' x 10' Assembly Instructions. We re Here To Help! Call Toll Free Section Roll In Dock Shown
4' x 10' Assembly Instructions TM 4 Section Roll In Dock Shown We re Here To Help! Call Toll Free 1-888-752-9782 Customer Service: Monday - Friday, 8:00 A.M. to 5:00 P.M. C.S.T. TABLE OF CONTENTS - ALUMINUM
More informationINSTALLATION & OWNER S MANUAL
INSTALLATION & OWNER S MANUAL CAB INSTALLATION INSTRUCTIONS KUBOTA GRAND L 30 SERIES HARD SIDED CAB ENCLOSURE (p/n 1KU3AS) SOFT SIDED CAB ENCLOSURE (p/n 1KU3SS) This Curtis Cab is designed and manufactured
More informationSAS International +44 (0) tubeline. tubular linear ceiling
metal ceilings SAS International +44 (0) 118 929 0900 www.sasint.co.uk tubeline tubular linear ceiling tubeline information System Description Tubeline is a visually striking linear ceiling system constructed
More information2-520-T Miro XTM FEATURES
2-520-T Miro XTM FEATURES P. 604.464.5644 T. 1.800.464.9544 F. 604.464.0888 TY WA R R A N SIGNED & DE SEMBLED AS RNIA T FO I LI T N 13 E TL 2-520-T-Miro-XTM-Specs Subject to change without notice Rev 2016.12.19
More informationSUT-450-I ASSEMBLY REQUIREMENTS
SUT-450-I Torque wrench, carpenters square, wire cutters, Phillips screwdriver, 7/16, 9/16, and 3/4 combination wrenches, ratchet, 9/16,3/4,13/16, and 7/8 sockets. ASSEMBLY REQUIREMENTS *Torque all T-bolt
More informationMÜPRO. One-piece pipe clamps. Sprinkler pipe clamps. Refrigerant pipe clamps. Two-piece pipe clamps. Heavy-duty pipe support/din pipe clamps
0. MÜPRO 1. Vibration control 2. Fire protection 3. Pipe clamps 4. Support channels 5. Accessories 6. Anchor points/expansion points 7. Heavy-duty pipe support 8. MPT-Support system 9. Ventilation 10.
More informationFluorescent Slot, Regressed Lens with MR16 Splay Aperture. Plaster Flange Flangeless. Donn Fineline Armstrong Bolt. Flange (All Ceilings)
DISPLAY & MISCELLANEOUS INDUSTRIAL WORKERS UNION TM VersaLux ARCHITECTURAL LIGHTING SERIES Fluorescent/ Point Source Slot Fluorescent Slot, Regressed Lens with MR16 Splay Aperture 6.2500" - (6.3750" -T8)
More informationG2.1 RETROFIT LED LIGHTING
INSTALLATION INSTRUCTIONS FOR CHEVRON CANOPY: G2.1 RETROFIT LED LIGHTING Please review site plans before proceeding. Contact LSI Graphic Solutions Plus Customer Service at 1-(800) 678-2001 for installation
More informationAUDIO & VIDEO SOLUTIONS
AUDIO & VIDEO SOLUTIONS Welcome to sonorahifi.com Home of Sonora furniture and brackets. Sonora is proudly designed and distributed by Daveco Ltd., as are Omage speakers, Maestro cables and power bars,
More informationM36 LED Recessed Quickship
Date: Customer: Project: Type: Qty: M36 Order Code: - 1B35 - - LW - - - WH - UNV - Series QL36 M36 LED Multi Mount Form Quickship QL36R1 Continuous Flange Quickship (Flanged Endcaps) 1B35 Light Engine
More informationInstallation Instructions
Equipment Required: Installation Instructions Fastener Kit: F Wrenches: 8mm, 13mm, 3/4, 15/16 Drill Bits: 1/4 Other Tools: Drill, Reciprocating Saw, File WARNING: Under no circumstances do we recommend
More informationSHOW YOUR PROFILE WITH OCTANORM ALUMINIUM PROFILES Overview of OCTANORM's extensive collection of extrusions. Product is sorted by function and form.
SHOW YOUR PROFILE WITH OCTANORM ALUMINIUM PROFILES Overview of OCTANORM's extensive collection of extrusions. Product is sorted by function and form. exhibition systems interior design systems presentation
More information6DS 6 Downlight Square
CATALOG #: L7 - L13: 5-7/8 L21: 7-3/8 6 TYPE: PROJECT: NEW CONSTRUCTION AND REMODEL FEATURES Dim to warm from 1800K to 3000K CCT, minimum 95 CRI Beam angles ranging from 25º narrow to 65º wide for tailored
More information1Unpack fixture. Suspensions/canopies are ordered and
DO NOT REMOVE THE LED ASSEMBLY. THIS WILL VOID THE WARRANTY. Call Zumtobel at 1-800-448-4131 questions. Fixture is intended installation in accordance with bee servicing. Retain these instructions 2Determine
More information3.25, 4.5, 7.5 Tabletop Conveyor Specifications
3.25, 4.5, 7.5 Tabletop Conveyor Specifications Complete Conveyor Systems and Equipment Conveyor Specifications Frame Material Thickness Material Finish Design 12 GA Mild steel Stardust Silver" powder
More informationTri-Boro Shelving Features
6Steel Shelving Tri-Boro Shelving Features Tri-Boro Shelving is manufactured in the widest range of sizes available in the industry. When used in combination this array of sizes can meet the most demanding
More information4DS 4.5 Downlight Square
CATALOG #: - : 5 : 6-1/2 4-1/2 5-1/2 TYPE: PROJECT: NEW CONSTRUCTION AND REMODEL FEATURES Dim to warm from 1800K to 3000K CCT, minimum 95 CRI 4 inch aperture is unobtrusive in small scale spaces Square
More informationStandard Installation Fire Damper Models: 319, 319(SS), D39
Standard Installation Fire Damper Models: 319, 319(SS), D39 Page 1 or 6 APPLICATION This fi re damper is intended to restrict the passage of fl ame. The standard installation requires that the damper is
More informationPrice O.R. Systems AIR CURTAIN SYSTEM
Price O.R. Systems AIR CURTAIN SYSTEM The Price Air Curtain System includes non-aspirating laminar flow diffusers directly above the surgical area with a surrounding four-sided linear slot diffuser system
More informationNON-SIZED SIZED HANDED
4410ME SERIES TOP JAMB (PUSH SIDE) MOUNTING The 4410ME SENTRONIC is a heavy duty, electrically controlled closer/holder designed to provide infinitely adjustable hold-open for fire and smoke barrier doors.