MIDDLE SECTION REPRESENTS "BLADE SIZE" (EXAMPLE: 24 = 24/32" [3/4"] 48 = 48/32" [1 1/2"]) REPRESENTS NUMBER OF BLADES PER 12" WIDE PANEL WG WB

Size: px
Start display at page:

Download "MIDDLE SECTION REPRESENTS "BLADE SIZE" (EXAMPLE: 24 = 24/32" [3/4"] 48 = 48/32" [1 1/2"]) REPRESENTS NUMBER OF BLADES PER 12" WIDE PANEL WG WB"

Transcription

1 HOW TO READ PRODUCT "SKU" : FIRST TWO LETTERS REPRESENT "PRODUCT TYPE" MIDDLE SECTION REPRESENTS "BLADE SIZE" (EXAMPLE: 24 = 24/32" [3/4"] 48 = 48/32" [1 1/2"]) REPRESENTS NUMBER OF BLADES PER 12" WIDE PANEL WG WB "SKU" ABBREVIATIONS: WG = REPRESENTS BACKER WB = WOOD BACK DWB= DOWELED & WOOD BACKED FB= FLEXIBLE BACKER RWB= RADIAL WOOD BACKED PRODUCT NOTES: S ARE MANUFACTURED IN PANELS 12" IN WIDTH. S ARE AVAILABLE IN LENGTHS OF 8' OR 10' (VENEER ONLY). SOLID WOOD ARE AVAILABLE IN LENGTHS UP TO 10', TYPICALLY SUPPLIED IN 1' INCREMENTS. CONTACT GEOMETRIK FOR INFORMATION REGARDING CUSTOM SIZES. GRILLES ARE CONSTRUCTED 1" SHORT OF EVEN QUOTED FOOT TO ALLOW FOR REQUIRED 1" EXPANSION REVEAL BETWEEN PANELS UPON INSTALLATION. EXAMPLE: 8' QUOTED LENGTH = 7'-11". SKU INFORMATION JUNE 6/2011 TM

2 SKU # BLADE SIZE # OF BLADES SKU # BLADE SIZE # OF BLADES 12" 12" 1 1/2" WG WB 1 1/2" X 3/4" 4 1 1/2" WG WB 1 1/2" X 3/4" 6 3/4" 2 1/4" 3/4" 1 1/4" 12" 12" WG WB 2" X 3/4" 4 WG WB 2" X 3/4" 6 2" 3/4" 2 1/4" WG WB 2 1/2" X 3/4" 4 WG WB 2 1/2" X 3/4" 6 2 1/2" 3/4" 2 1/4" WG WB 3" X 3/4" 4 WG WB 3" X 3/4" 6 3" 3/4" 2 1/4" WG WB 3 1/4" X 1 3/8" 4 3 1/4" 2" 3/4" 1 1/4" 12" 12" 2 1/2" 3/4" 1 1/4" 12" 12" 3" 3/4" 1 1/4" 12" 1 3/8" 1 5/8" 12" 1 1/4" WG WB 1 1/4" X 1 1/4" 4 1 1/4" 1 3/4" STANDARD CONFIGURATIONS JUNE 6/2011 TM

3 SKU # BLADE SIZE # OF BLADES SKU # BLADE SIZE # OF BLADES 12" 12" 1 1/2" WG WB 1 1/2" X 3/4" 7 1 1/2" WG WB 1 1/2" X 3/4" 10 3/4" 15/16" 3/4" 7/16" 12" 1 3/8" WG WB 1 3/8" X 3/4" 8 3/4" 3/4" 12" 1 1/2" WG WB 1 1/2" X 3/4" 8 3/4" 3/4" 12" WG WB 2" X 3/4" 8 2" 3/4" 3/4" 12" WG WB 2 1/2" X 3/4" 8 2 1/2" 3/4" 3/4" STANDARD CONFIGURATIONS JUNE 6/2011 TM

4 12 GA. WIRE PAINTED BLACK BLACK HEAVY DUTY 15/16 CROSS 4'-0" O.C. FOR LATERAL STABILITY BLACK HEAVY DUTY 15/16" MAIN 2'-0" O.C. WALL BLACK HEAVY DUTY 15/16 CROSS 4'-0" O.C. FOR LATERAL STABILITY 12 GA. WIRE PAINTED BLACK BLACK HEAVY DUTY 15/16" T-BAR 2' O/S 1" REVEAL STANDARD 12" WIDE BLACK SELF-TAPPING SCREWS 1" REVEAL 6" (MAXIMUM RECOMMENDED) BLACK SELF-TAPPING SCREWS SCREW SUSPENSION JUNE 6/2011 TM

5 12 GA. WIRE PAINTED BLACK BLACK HEAVY DUTY 15/16 CROSS 4'-0" O.C. FOR LATERAL STABILITY BLACK HEAVY DUTY 15/16" MAIN 2'-0" O.C. WALL BLACK HEAVY DUTY 15/16 CROSS 4'-0" O.C. FOR LATERAL STABILITY 12 GA. WIRE PAINTED BLACK BLACK HEAVY DUTY 15/16" T-BAR 2' O/S 1" REVEAL STANDARD 12" WIDE BLACK SELF-TAPPING SCREWS 1" REVEAL 6" (MAXIMUM RECOMMENDED) BLACK SELF-TAPPING SCREWS FACTORY INSTALLED WOOD DOWEL PAINTED BLACK SCREW SUSPENSION W/ DOWEL JUNE 27/2011 TM

6 WALL 12 GA. WIRE PAINTED BLACK BLACK HEAVY DUTY 15/16 CROSS 4'-0" O.C. FOR LATERAL STABILITY BLACK HEAVY DUTY 15/16" MAIN 2'-0" O.C. WALL BLACK HEAVY DUTY 15/16 CROSS 4'-0" O.C. FOR LATERAL STABILITY 12 GA. WIRE PAINTED BLACK BLACK HEAVY DUTY 15/16" T-BAR 2' O/S GEOMETRIK BACKER CLIPS (MIN. 6 NEEDED PER PANEL) 1" REVEAL STANDARD 12" WIDE GEOMETRIK BACKER CLIP (MIN. 6 NEEDED PER PANEL 1" REVEAL 6" (MAXIMUM RECOMMENDED) T-BAR & BACKER CLIP SUSPENSION JUNE 6/2011 TM

7 BLACK HEAVY DUTY 15/16" MAIN 2'-0" O.C. GEOMETRIK BACKER CLIPS - MIN. 6 NEEDED PER PANEL BACKER CLIP PLACEMENTS ISOMETRIC VIEW JUNE 6/2011 TM

8 EXAMPLE: 95" (7'-11") BLACK HEAVY DUTY 15/16" MAIN 2'-0" O.C. GEOMETRIK BACKER CLIPS - MIN. 6 NEEDED PER PANEL 5 1/2" 12" 5 1/2" 24" BLACK HEAVY DUTY 15/16" MAIN 2'-0" O.C. NOTE: BACKER CLIPS MUST BE NO MORE THAN 4' (48") APART STANDARD 12" WIDE GEOMETRIK BACKER CLIPS - MIN. 6 NEEDED PER PANEL BACKER CLIP PLACEMENTS JUNE 6/2011 TM

9 12 GA. WIRE CURVED T-BAR (OPTIONAL) FLEXIBLE BLACK BACKER (BY GEOMETRIK) BLADES BLACK SELF-TAPPING SCREWS CURVED TYPICAL INSTALLATION MAR KM/TM

10 CROSS RUNNER 15/16" T-BAR CROSS RUNNER 15/16" T-BAR 23" 23" CROSS RUNNER 15/16" T-BAR BLADES SECURITY WIRE MAIN 15/16" T-BAR SECURITY WIRE BLADES MAIN 15/16" T-BAR MAIN 15/16" T-BAR TEGULAR INSTALLATION DETAILS JUNE TM

11 MAIN HEAVY DUTY 15/16" T-BAR CROSS RUNNER 15/16" T-BAR TEGULAR EDGE DETAIL TEGULAR INSTALL ISOMETRIC DETAIL MAR KM/TM

12 1" x 1/2" BLACK WOOD BACKER BLACK HEAVY DUTY 15/16" T-BAR MATCHING WOOD TRIM (OPTIONAL) DROP IN DETAIL MAR KM/TM

13 WALL 12 GA. WIRE PAINTED BLACK BLACK HEAVY DUTY 15/16" T-BAR 2' O/S 1" REVEAL GEOMETRIK BACKER CLIP -MIN. 6 PER PANEL BLADES PERIMETER DETAIL MAR KM/TM

14 12 GA. WIRE PAINTED BLACK BLACK HEAVY DUTY 15/16 CROSS 4'-0" O.C. FOR LATERAL STABILITY BLACK HEAVY DUTY 15/16" MAIN 2'-0" O.C. OPTIONAL MATCHING TRIM - TYP. 12 GA. WIRE PAINTED BLACK BLACK HEAVY DUTY 15/16" T-BAR 2' O/S GEOMETRIK BACKER CLIPS (MIN. 6 NEEDED PER PANEL) STANDARD 12" WIDE GEOMETRIK BACKER CLIP (MIN. 6 NEEDED PER PANEL 3/4" REVEAL 6" (MAXIMUM RECOMMENDED) OPTIONAL MATCHING TRIM - TYP. PERIMETER TRIM DETAIL AUG 23/2011 KM

15 DESIRED CUT LINE ATTACH BACKER BEFORE CUTTING. MUST BE WITHIN 6" OFF CUT LINE. 6" MAX PANEL BEFORE CUTTING PANEL AFTER CUTTING FIELD CUTTING PROCEDURES APR KM/TM

16 ADDITIONAL GEOMETRIK WOOD BACKERS ADDED NEAR CUTOUT TO STABILIZE GRILLES PRIOR TO CUTTING LIGHT FIXTURE SUPPORT WIRE (BY OTHERS) ADDITIONAL 1" X 1/2" BLACK WOOD BACKERS LIGHT FIXTURE BLACK HEAVY DUTY 15/16" T-BAR FIXTURE FILLER (OPTIONAL) 6" MAX. 6" MAX. GEOMETRIK BACKER CLIP FIXTURE BRACKET (BY OTHERS) TRIM (BY LIGHT MFR.) FIXTURE FILLER (OPTIONAL) POT LIGHT INSTALLATION DETAIL APR KM/TM

17 INDEPENDENT LIGHT SUSPENSION WIRES (BY OTHERS) ADDITIONAL GEOMETRIK WOOD BACKERS ADDED NEAR CUTOUT TO STABILIZE GRILLES PRIOR TO CUTTING POSSIBLE LIGHT FIXTURE LOCATIONS. INTER-PANEL AND INTERNAL PLACEMENT. POT LIGHT INSTALLATION DETAIL ISOMETRIC - NO INSERT MAR TM

18 LIGHT FIXTURE SUPPORT WIRE (BY OTHERS) ADDITIONAL 1" X 1/2" BLACK WOOD BACKERS LIGHT FIXTURE 6" MAX. 6" MAX. BLACK HEAVY DUTY 15/16" T-BAR GEOMETRIK BACKER CLIP PANEL PANEL FIXTURE BRACKET (BY OTHERS) TRIM (BY LIGHT MFR.) PANEL POT LIGHT INSTALLATION DETAIL - NO INSERT APR KM/TM

19 FLUORESCENT LIGHT 2 WG7.4 USE CUTOFF PIECE OF PANEL GRILLE BLADE AS TRIM. ATTACH AS NECESSARY. 1 WG7.4 FLUORESCENT LIGHT PLAN VIEW MAR KM/TM

20 HANGER WIRE FOR INDEPENDENT LIGHT FIXTURE SUSPENSION HANGER WIRE FOR INDEPENDENT LIGHT FIXTURE SUSPENSION FLUORESCENT LIGHT FIXTURE FLUORESCENT LIGHT FIXTURE CUT PANEL BLADES AS REQUIRED CENTER FIXTURE IN OPENING USE SECTION OF CUT PANEL GRILLE BLADE FOR TRIM. SECURE AS REQUIRED. 1 WG7.3 SECTION THRU PANEL SCALE: NTS 2 WG7.3 SECTION ALONG PANEL SCALE: NTS FLUORESCENT LIGHT SECTIONS MAR KM/TM

21 BLACK HEAVY DUTY 15/16" T-BAR GEOPANEL GRILLE TYP. SPRINKLER HEAD (BY OTHERS) SPRINKLER MAR KM/TM

22 BLACK HEAVY DUTY 15/16" T-BAR SEISMIC WIRE MUST HAVE 3 TURNS IN 1 1/2" BLADES GEOMETRIK BACKER CLIP BACKER CLIP PLACEMENT - SEISMIC JUNE 6/2011 TM

23 3 1/2" X 20 GA. STEEL STUD COMPRESSION MEMBER GA. WIRE BRACES IN PLANE OF EACH T-BAR MAIN AND 2 IN PLANE OF CROSS RUNNER. VERTICAL ANGLES OF 45. CROSS RUNNER 2 SCREWS TO HEAVY DUTY 15/16" MAIN T-BAR SEISMIC BRACING CEILING DETAIL MAR 22/2011 TM

24 12 GAUGE SPLAY 6' O/C 12 GAUGE HANGER EACH RUNNER FOR SEISMIC MAIN T-BAR POP RIVET OR NO. 6 TEK SCREW CROSS T SLOT MAIN T-BAR NOTE: WALL ANGLE BRACKET ANCHORED TO STRUCTURAL ELEMENT. POP RIVET RUNNER TO ANGLES. SAME APPLICATION TO CROSS RUNNERS. SEISMIC BRACING HEIGHT CHANGE MAR KM/TM

25 STRUCTURAL CEILING 12 GAUGE VERTICAL HANGER WIRE STEEL STRAP - 1" WIDE X 2" LONG X 12 GAUGE MIN. 1/4" DIA. SELF-TAPPING CONCRETE SCREW ANCHORS - 1 1/4" EMBEDMENT SPLAYED SEISMIC BRACING WIRE MIN. 3 TURNS CROSS T SLOT CROSS RUNNER 12 GAUGE VERTICAL HANGER WIRE MAIN T-BAR TYPICAL CONNECTION OF WIRES TO STRUCTURE. TYPICAL SUSPENSION AT 4' O/C MAX. BETWEEN BRACING ASSEMBLY LOCATIONS. SEISMIC BRACING BRACE ANCHOR MAR KM/TM

26 6'-0" [1829.7] 12'-0" [3659.3] 12 GAUGE VERTICAL HANGER WIRE 6'-0" [1829.7] 8" MAX. 1/2" MAX. 12'-0" [3659.3] CROSS T SLOT MAIN T-BAR CEILING RESTRAINT SEE DRAWING WG.20 WALL ANGLE BRACKET ANCHORED TO STRUCTURAL ELEMENT. POP RIVET RUNNER TO ANGLES. SAME APPLICATION TO CROSS RUNNERS. PERIMETER WALL DETAIL CEILING GRID LAYOUT SEISMIC BRACING GRID PLAN MAR KM/TM

27 ACOUSTIC INSULATION IF REQ'D ACOUSTIC INSULATION IF REQ'D. BLADES ACOUSTIC FABRIC BACKER (OPTIONAL) BLADES WALL 2'-0" 1" X 1/2" BLACK WOOD BACKER WALL ACOUSTIC FABRIC BACKER (OPTIONAL) 1 - SCALE: NTS SIDE VIEW - SECTION 2 - SCALE: NTS TOP VIEW - SECTION BLACK SCREW ACOUSTIC FABRIC BACKER (OPTIONAL) WOOD FURRING STRIP WALL MOUNT DETAILS VERTICAL BLADE JUNE 6/2011 TM

28 1-2 - ACOUSTIC INSULATION IF REQ'D. ACOUSTIC INSULATION IF REQ'D. 2'-0" WALL BLADES ACOUSTIC FABRIC BACKER (OPTIONAL) 1" X 1/2" BLACK WOOD BACKER ACOUSTIC FABRIC BACKER (OPTIONAL) BLADES WALL 1 - SCALE: NTS SIDE VIEW - SECTION 2 - SCALE: NTS TOP VIEW - SECTION WOOD FURRING STRIP 1" X 1/2" BLACK WOOD BACKER BLACK SCREW ACOUSTIC FABRIC BACKER (OPTIONAL) BLADES WALL MOUNT DETAILS HORIZONTAL BLADE JUNE 6/2011 TM

INTERIOR INSTALLATION

INTERIOR INSTALLATION HOOK ON CROSS CONNECTOR CLAMP AT ALL INTERSECTIONS OF S 4-1 4" PANEL 1/2" x 1-1/2" 16 GA CR CHANNEL PRIMARY AT 48" O.C. MAX SPACING, TYPICAL. PANEL 1 1 2 " 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS.

More information

12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL A1.1 MAIN RUNNER SPLICE. SPECIFICATIONS (unless noted otherwise)

12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL A1.1 MAIN RUNNER SPLICE. SPECIFICATIONS (unless noted otherwise) 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL A1.1 4' OPEN CELL RUNNER SEE DETAIL A1.7 FOR INFILL PANEL FIXTURE OPENING RECOMMENDATIONS CROSS RUNNER FIELD CUT AT PERIMETER TYPICAL SYSTEM

More information

DETAIL 'A' INTERIOR INSTALLATION. OVERALL ISOMETRIC VIEW (unless noted otherwise) 300C CARRIER 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS

DETAIL 'A' INTERIOR INSTALLATION. OVERALL ISOMETRIC VIEW (unless noted otherwise) 300C CARRIER 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS 3 " NOM. 316 G, ER V RO N HA. TYP SEE DETAILS A1.7 THROUGH A1.10 FOR FIXTURE OPENING RECOMMENDATIONS IE ARR XC 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL A1.2 A "M 1'-0 300C PANEL SPLICE

More information

Section 3. Custom. Recessed

Section 3. Custom. Recessed Section 3 Custom Recessed BX Connector 13.375" 11.375" Hanging Cable Typ (By others) Threaded Rod Typ (By others) 23.375" OAL Fixture Lamp Housing PAR30 Lamp Holder Ballast Compartment 6.781" 45 " 12.000"

More information

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility 22860 900" D D 914 36" 1000 39 3/8" SOIL AND TARMAC CUT-OUT CONCRETE TARMAC BRIDGE DECK B PLAN VIEW C A C 15 20 [3/4"] Deck Gap BRIDGE DECK A 3900 153 1/ Impact 30V 45720 1800" 34290 13" 11430 4" RAIL

More information

Installation STUD JOIST A237R SPECIFICATIONS. Width Height Depth Weight Max. Spacing between Mounts Max. Load

Installation STUD JOIST A237R SPECIFICATIONS. Width Height Depth Weight Max. Spacing between Mounts Max. Load WILREP LTD. 08 13 48 13 SPECIAL CONSTRUCTION 14 manufactured sound & vibration control components Installation A237R SPECIFICATIONS Width Height Depth Weight Max. Spacing between Mounts Max. Load FURRING

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS This document explains mounting for pendant, recessed, and wall PENDANT - STEP ONE INSTALL MOUNTING POINTS Non-power feed mounting points may be positioned 1 to 12 or 12 to 18

More information

TG/RB/2M/Web Rev.12/1/16. Pipe Hangers & Devices

TG/RB/2M/Web Rev.12/1/16. Pipe Hangers & Devices TG/RB/2M/Web Rev.12/1/16 Pipe Hangers & Devices Pipe Welcome Hangers to PHD & Devices Manufacturing PHD Manufacturing, Inc. was founded in 1972 by a group of industry veterans with strong management, financial,

More information

AXIOM CIRCLE & CURVED CANOPIES For Tegular 8 mm & MicroLook 8 mm reveal edge tiles

AXIOM CIRCLE & CURVED CANOPIES For Tegular 8 mm & MicroLook 8 mm reveal edge tiles CI/Sf (35) Xy pril 06 XIOM CIRCLE & CURVED CNOPIES For Tegular 8 mm & MicroLook 8 mm reveal edge tiles Installation uide PREPRTION SUSPENSION POINTS Suspension points should be determined before installing

More information

Chicago Metallic /16

Chicago Metallic /16 Part of The ROCKWOOL Group Chicago Metallic 1200 15/16 coustical ceiling suspension system Ideal for: Retail, classrooms, general interiors. Performance Properties: -coustical grid system comes in intermediate

More information

Fluorescent Slot, Regressed Lens with MR16 Splay Aperture. Plaster Flange Flangeless. Donn Fineline Armstrong Bolt. Flange (All Ceilings)

Fluorescent Slot, Regressed Lens with MR16 Splay Aperture. Plaster Flange Flangeless. Donn Fineline Armstrong Bolt. Flange (All Ceilings) DISPLAY & MISCELLANEOUS INDUSTRIAL WORKERS UNION TM VersaLux ARCHITECTURAL LIGHTING SERIES Fluorescent/ Point Source Slot Fluorescent Slot, Regressed Lens with MR16 Splay Aperture 6.2500" - (6.3750" -T8)

More information

Armstrong Trulok Suspension System Accessories (56GA)

Armstrong Trulok Suspension System Accessories (56GA) Armstrong Trulok Suspension System Accessories (56GA) A comprehensive range of accessories which provide a high standard of both installation and finished appearance to Armstrong suspension systems. Images:

More information

Pipe hanger solutions

Pipe hanger solutions Product catalog Middle East offering Pipe hanger solutions for commercial and industrial applications B00 series B00 - Standard clevis hanger Pipe will not pinch when installing. 5 swing in either direction

More information

FREESTANDING WOOD FIRES GRANDVIEW (NZ & AUST) Fan Three Speed - DE Page 6. Flue 175mm Hi Therm - 4m SFP1003

FREESTANDING WOOD FIRES GRANDVIEW (NZ & AUST) Fan Three Speed - DE Page 6. Flue 175mm Hi Therm - 4m SFP1003 Issue F December 2005 REF # 795981 FREESTANDING WOOD FIRES GRANDVIEW (NZ & AUST) NZ AUST Grandview Charcoal VHT S2 995939 Page 2 Charcoal VHT S3 995981 Page 2 Fan Three Speed - DE 995557 995557 Page 6

More information

GRANDVIEW (NZ & AUST) From Serial Number NZ AUST. Issue A September 2000 IPL Part # Part Numbers Matt Black Moss Green

GRANDVIEW (NZ & AUST) From Serial Number NZ AUST. Issue A September 2000 IPL Part # Part Numbers Matt Black Moss Green Issue A September 2000 IPL Part # 795927 (NZ & AUST) NZ AUST Part Numbers Matt Black 995926 995927 Moss Green 995529 From Serial Number 3011594 Issue A September 2000 IPL Part # 795927 Page 2 1 795521

More information

Window Regulator: Service and Repair Front Door Trim. Armrests. With Power Windows. Front Door Arm Rest. Remove or Disconnect

Window Regulator: Service and Repair Front Door Trim. Armrests. With Power Windows. Front Door Arm Rest. Remove or Disconnect 1995 Oldsmobile Cutlass Ciera V6-3100 3.1L VIN M SFI Page 1 Window Regulator: Service and Repair Front Door Trim Armrests 1. Plugs from upper and lower armrest openings. 2. Screws from upper and lower

More information

AABTLAC by Prentice Hall, Inc. A Pearson Company

AABTLAC by Prentice Hall, Inc. A Pearson Company Figure Number: 08-01 a,b Caption: Regular Views and Auxiliary Views. AABTLAC0 Figure Number: 08-02 a-c Caption: An Auxiliary View. AABTLAD0 Figure Number: 08-03 1-4 Caption: Drawing an Auxiliary View Folding-Line

More information

TOOLS REQUIRED FOR ASSEMBLY. Rubber Mallet or Plastic Tip Hammer PARTS REQUIRED FOR ASSEMBLY OF SINGLE ENTRY STARTER.

TOOLS REQUIRED FOR ASSEMBLY. Rubber Mallet or Plastic Tip Hammer PARTS REQUIRED FOR ASSEMBLY OF SINGLE ENTRY STARTER. TOOLS REQUIRED FOR ASSEMBLY Rubber Mallet or Plastic Tip Hammer Top Cover Support PARTS REQUIRED FOR ASSEMBLY OF SINGLE ENTRY STARTER Back Stop Divider Closed 'L' Upright Slotted Reinforcement Support

More information

argco.com

argco.com 800-854-1015 argco.com STRUT SUPORT SYSTEM STRUT SUPPORT CHANNEL US Strut Support Channel Quick, strong attachment of single or multiple pipes horizontally or vertically Unlimited applications - range

More information

Chicago Metallic 200 Snap Grid 15/16

Chicago Metallic 200 Snap Grid 15/16 Part of The ROCKWOOL Group Chicago Metallic 200 Snap Grid 15/16 coustical ceiling suspension system Ideal for: Retail, classrooms, general interiors. Performance Properties: -Intermediate and heavy duty

More information

Plaster Flange Flangeless. Flange (All Ceilings) Donn Fineline Armstrong Bolt

Plaster Flange Flangeless. Flange (All Ceilings) Donn Fineline Armstrong Bolt DISPLAY & MISCELLANEOUS INDUSTRIAL WORKERS UNION VersaLux ARCHITECTURAL LIGHTING SERIES TM Fluorescent Slot Fluorescent Slot, Regressed Lens 6.2500" - (6.3750" -T8) Acrylic Lens Regressed 1.25" Ceiling/Trim

More information

Cetra Assembly Instructions

Cetra Assembly Instructions 99877 Revision F- Complete Series Master Packet If you have any questions concerning these instructions, please call Kimball Office Customer Service. 0 Kimball International, Inc. T 800.8.88 F 8.8.800

More information

Plaster Flange Flangeless. Donn Fineline Armstrong Bolt. Flange (All Ceilings)

Plaster Flange Flangeless. Donn Fineline Armstrong Bolt. Flange (All Ceilings) & TM VersaLux ARCHITECTURAL LIGHTING SERIES Fluorescent Slot Fluorescent Slot, Flush Lens Ceiling/Trim Options Plaster less Drywall Fellert (All Ceilings) Donn Fineline Armstrong Bolt TechZone 9/16 Superfine

More information

LAWN TRACTORS MANUAL CLUTCH HYDRO DRIVE SERIES "G"

LAWN TRACTORS MANUAL CLUTCH HYDRO DRIVE SERIES G Parts Manual for LAWN TRACTORS MANUAL CLUTCH HYDRO DRIVE SERIES "G" MODEL ELT145H33GBV LT145H33GBV LT145H38GBV LT150H38GKV WLT145H38GKV McDonough, GA, 30253 U.S.A. COPYRIGHT 2006 SNAPPER PRODUCTS, INC.

More information

MG 3000 Natural Gas/LPG

MG 3000 Natural Gas/LPG Issue B April 1998 Part # 788821 MG 3000 Natural Gas/LPG (New Zealand - Flueless) Part Numbers Natural Gas Matt Black 988821 Forest Green 988823 LPG Matt Black 988822 Forest Green 988824 From Serial Number

More information

Plaster Trim Flange Trim Trimless. for ceilings requiring a flange. Donn Fineline Armstrong Bolt

Plaster Trim Flange Trim Trimless. for ceilings requiring a flange. Donn Fineline Armstrong Bolt & VersaLux ARCHITECTURAL LIGHTING SERIES Fluorescent Slot Fluorescent Slot, Flush Lens TM 3.6250" Ceiling/Trim Detail Plaster Trim Flange Trim Trimless Drywall Fellert for ceilings requiring a flange Donn

More information

Parts Manual for LAWN TRACTORS MANUAL CLUTCH HYDRO DRIVE SERIES F MODELS LT145H33FBV LT145H38FBV ELT145H33FBV

Parts Manual for LAWN TRACTORS MANUAL CLUTCH HYDRO DRIVE SERIES F MODELS LT145H33FBV LT145H38FBV ELT145H33FBV Parts Manual for LAWN TRACTORS MANUAL CLUTCH HYDRO DRIVE SERIES F MODELS LT145H33FBV LT145H38FBV ELT145H33FBV IT IS THE POLICY OF SNAPPER TO IMPROVE ITS PRODUCTS WHENEVER IT IS POSSIBLE AND PRACTICAL TO

More information

CUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER

CUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER ARCHITECTURAL SLOT DIFFUSER Custom Flow (CF) slot diffusers are uniquely designed for curving and long continuous installations. The CF offers a large range of airflow flexibility with one or two slot

More information

WESTERN SPECIFIER. Technical Data for PWI Joists, PWLVL Headers, Beams, Rim Board, Stud, and Dimension

WESTERN SPECIFIER. Technical Data for PWI Joists, PWLVL Headers, Beams, Rim Board, Stud, and Dimension E N G I N E E R E D W O O D WESTERN SPECIFIER Technical Data for PWI Joists, PWLVL Headers, Beams, Rim Board, Stud, and Dimension P R O D U C T S JOIST DIMENSIONS 9½ LVL FLANGE PWI JOIST SERIES JOIST DIMENSIONS

More information

Laminar ceilings, exhaust columns, exhaust grilles

Laminar ceilings, exhaust columns, exhaust grilles Laminar ceilings, exhaust columns, exhaust grilles 1 Table of Contents: 1. Laminar ceilings general information... 3 2. Laminar ceilings design and operation principles... 4 3. Parameters of air in the

More information

Electrical Applications. Metal Framing & Cable Tray Superstrut Metal Framing System. Column A. Design Data: Materials: Column B

Electrical Applications. Metal Framing & Cable Tray Superstrut Metal Framing System. Column A. Design Data: Materials: Column B Electrical Raceway Series 800 Surface Raceway and Lighting Systems Superstrut channel together with snap-in closure strip is listed by Underwriters Laboratories as a surface metal raceway. Other accessories

More information

SECTION CENTRIFUGAL HVAC FANS

SECTION CENTRIFUGAL HVAC FANS SECTION 233416 - CENTRIFUGAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery Alpha System ADAPTABLE LABORATORY FURNITURE KEWAUNEE encouraging new discovery Alpha 6 partition modules with Kemresin worktops. Minneapolis, Minnesota Alpha 6 partition modules with Alpha overhead service

More information

TO BE USED FOR MAINTENANCE MICHIGAN DEPARTMENT OF TRANSPORTATION. 2 3/16" x 2 3/16" x 10 Ga. 12" 15.5" 1 1/2" x 1 1/2" x 12 Ga.

TO BE USED FOR MAINTENANCE MICHIGAN DEPARTMENT OF TRANSPORTATION. 2 3/16 x 2 3/16 x 10 Ga. 12 15.5 1 1/2 x 1 1/2 x 12 Ga. 2 3/16" x 2 3/16" x 10 Ga. TOP VIEW 18" 1" 7/16" Hole 1 1/2" x 1 1/2" x 12 Ga. two sides only steel tubing 1 1/2" x 1 1/2" x 12 Ga. @ 18" long steel angle 15.5" 12" TRAFFIC 3/8" Hex head grade 5 steel

More information

Wall/Slot -II 85N Recessed Perimeter

Wall/Slot -II 85N Recessed Perimeter Type: Project: Wall/Slot -II 85N Recessed Perimeter Specifications 10 1/2 (267 ± 19) 9" (229) baffle shown in flush F/position 3 5/8" (92) FIXTURE SUPPORT RAIL. Extruded white aluminum, wall-mounted rail

More information

COMPACT BUSWAY 40 & 60 AMP HOUSING

COMPACT BUSWAY 40 & 60 AMP HOUSING 40 & 60 AMP HOUSING B40 & HOUSING Each Track Busway housing section consists of an extruded aluminum housing with an insulated strip containing copper conductors mounted on the top interior wall. The aluminum

More information

FREESTANDING WOOD FIRES LE 5000 S2. LE 5000 Black Page 2 Grey Page 2

FREESTANDING WOOD FIRES LE 5000 S2. LE 5000 Black Page 2 Grey Page 2 Issue A April 2004 REF # 786998 FREESTANDING WOOD FIRES LE 5000 Black 986998 Page 2 Grey 986999 Page 2 Fans Three Speed SE - Black 986364 Page 6 Three Speed DE - Black 995370 Page 7 Fan Assy-Remote Control

More information

MG 3000 Natural Gas/LPG

MG 3000 Natural Gas/LPG April 1997 Part # 788955 MG 3000 Natural Gas/LPG (New Zealand - Flueless) Part Numbers Natural Gas Matt Black 988955 Warm White 988957 Forest Green 988959 LPG Matt Black 988956 Warm White 988958 Forest

More information

product family TechZone available with Lyra, Optima, Calla, Ultima, MetalWorks, and WoodWorks panels

product family TechZone available with Lyra, Optima, Calla, Ultima, MetalWorks, and WoodWorks panels product family 1 2techzone echzone available with Lyra, Optima, Calla, Ultima,, and WoodWorks panels Organized. Simple. Clean. Cut the clutter lighting, air diffusers and returns, sprinkler systems, etc.

More information

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING: MEDIA LED Pendant Standard Mount WARNING: Disconnect main power at the source prior to installation! Thread gripper base onto 1 /4 20 stud, or with #8 screw. Depress gripper nozzle to insert aircraft cable.

More information

300 SERIES STANDARD DUTY CURVED TRACK

300 SERIES STANDARD DUTY CURVED TRACK 300 SERIES STANDARD DUTY CURVED TRACK COMPLETE TRACK MODEL NUMBERS 301A 301W 316A 316W 328A 328W 300B SERIES BLACK CURVED TRACK COMPLETE TRACK MODEL NUMBERS 301AB 301WB 316AB 316WB 328AB 328WB SINGLE CARRIER

More information

A B C D E F 113' - 2" 22' - 6" 22' - 6" 22' - 6" 22' - 6" 23' - 2" A A A3.11 A3.

A B C D E F 113' - 2 22' - 6 22' - 6 22' - 6 22' - 6 23' - 2 A A A3.11 A3. .09 DASHED LINE INDICATES ROOF OVERHEAD..0 DASHED LINE INDICATE CANOPY OVERHEAD. ' - " ' - " ' - " ' - " ' - " ' - " A. A.0 9' - " ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" A.0 A.0 UNIT 0 UNIT 0

More information

friendly TECHZONE Ceiling Systems Easy Steps to Designing Your TechZone Ceiling cloud CAD/Revit drawings at: armstrongceilings.

friendly TECHZONE Ceiling Systems Easy Steps to Designing Your TechZone Ceiling cloud CAD/Revit drawings at: armstrongceilings. Easy Steps to Designing Your echzone Ceiling CD/Revit drawings at: armstrongceilings.com/ details cloud friendly Optima 48" x 48" egular field panels, Optima Lay-in echzone panels with Suprafine XL 9/16"

More information

Acoustical. Pages Watch for this icon for compatibility with new taller grid profile. Ph:

Acoustical. Pages Watch for this icon for compatibility with new taller grid profile. Ph: Watch for this icon for compatibility with new taller grid profile Pages 175-190 Sold by: http://www.twacomm.com Toll Free: (877) 892-2666 175 Lay In And Troffer Light Fixture Support Clips The original

More information

ORDERING: Specify size, figure number, description, nominal pipe size or special O.D. and C-to-C dimension. C - C LOAD lb.

ORDERING: Specify size, figure number, description, nominal pipe size or special O.D. and C-to-C dimension. C - C LOAD lb. Fig. 2110 www.pipingtech.com/fig2110 Sway Strut with 4 of Adjustment Engineered spring supports option 1 option 2 ORDERING: Specify size, figure number, description, nominal pipe size or special O.D. and

More information

NOTE: CAPACITOR LEADS IN FIG #1 MAY REQUIRE SPLICING USING GA BUSS WIRE & SLEEVING AS NECESSARY TO ATTAIN REQUIRED LEAD LENGTH. 704

NOTE: CAPACITOR LEADS IN FIG #1 MAY REQUIRE SPLICING USING GA BUSS WIRE & SLEEVING AS NECESSARY TO ATTAIN REQUIRED LEAD LENGTH. 704 DIGITAL READ OUT (2.70 IDEAL FOR THIS RESISTOR) ENGAGE DCVΩ BUTTON DIGITAL VOLT METER ZERO ADJUST-CONNECT (2) ALLIGATOR CLIPS TOGETHER & ADJUST UNTIL DIGITAL READ OUT IS 0.00 NOTE: THIS MUST BE REPEATED

More information

Pipe Brackets - Pipe Support. Systems Brass Pipe brackets Brass Pipe clips

Pipe Brackets - Pipe Support. Systems Brass Pipe brackets Brass Pipe clips Select Language Home Profile Products Contact Us Email Resources Brass Sanitary Fittings Brass Cable Glands Cable Gland Accessories Brass Fasteners Pipe Brackets - Pipe Support Systems Brass Pipe brackets

More information

SafeLite Installation Steps For a 2 x 2 Light Fixture

SafeLite Installation Steps For a 2 x 2 Light Fixture SafeLite Installation Steps For a 2 x 2 Light Fixture SafeLite Installation Instructions Fluorescent Fixtures (Refer to Diagrams) 1) For existing ceiling applications, remove ceiling tile from both sides

More information

VERONA WOOD FIRES. (New Zealand/Australia) Serial Number From. Month and Year of Manufacture: Issue B January 2003 REF # NZ AUST

VERONA WOOD FIRES. (New Zealand/Australia) Serial Number From. Month and Year of Manufacture: Issue B January 2003 REF # NZ AUST Issue B January 2003 REF # 795947 WOOD FIRES (New Zealand/Australia) NZ AUST Part Numbers Matt Black 995947 995949 Charcoal 995948 Serial Number From Month and Year of Manufacture: Issue B January 2003

More information

LAWN TRACTORS ELECTRIC CLUTCH HYDRO DRIVE SERIES "G"

LAWN TRACTORS ELECTRIC CLUTCH HYDRO DRIVE SERIES G Parts Manual for LAWN TRACTORS ELECTRIC CLUTCH HYDRO DRIVE SERIES "G" MODEL LT160H42GBV LT160H42GBV2 LT180H48GBV2 WLT160H42GBV WLT180H48GBV2 McDonough, GA, 30253 U.S.A. COPYRIGHT 2006 SNAPPER PRODUCTS,

More information

SECTION HVAC POWER VENTILATORS

SECTION HVAC POWER VENTILATORS SECTION 233423 HVAC POWER VENTILATORS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Choice of mud-in flange or overlap trims and cover profiles for custom appearances. Two-channel design for multiple zone controls

Choice of mud-in flange or overlap trims and cover profiles for custom appearances. Two-channel design for multiple zone controls by Recessed Power Track Housing is a revolutionary all-in-one slot power delivery system. Express your creativity by dynamically repositioning every light fixture to personalize your lighting design. FEATURES

More information

ZIP LIGHT LED LUMINAIRE

ZIP LIGHT LED LUMINAIRE LED LUMINAIRE INSTALLATION MANUAL Note: Follow the Electrical Codes of the Country where this fixture will be installed. For Canada follow the Canadian Electrical Code (CE) and for the United States follow

More information

Wildcat System Instructions

Wildcat System Instructions Wildcat System Instructions NOTE: Most steps contained in these instructions will need to be repeated on the other side of the vehicle. Prior to assembly of windshield it is necessary to establish what

More information

SEISMIC RESTRAINTS Multi-Directional Bracing For Electrical Conduit, Cable Tray And Mechanical Piping Systems

SEISMIC RESTRAINTS Multi-Directional Bracing For Electrical Conduit, Cable Tray And Mechanical Piping Systems SEISMIC RESTRAINTS Multi-Directional Bracing For Electrical Conduit, Cable Tray And Mechanical Piping Systems SYSTEMS THAT MAKE SENSE INTRODUCTION INTRODUCTION What is Seismic Bracing? Seismic forces are

More information

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh)

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh) Product Data WEATHERMASTER 36S Water Control Induction Air Terminals 19.4 to 131.9 cfm (1770 to 8900 Btuh) Induction air terminals offer: Heating and cooling operation 2-pipe or 4-pipe system options Automatic

More information

TruckSkin F.A.Q.s and Tips

TruckSkin F.A.Q.s and Tips 1 TruckSkin F.A.Q.s and Tips Here are some helpful answers and tips for your self installation. You can see more installation information on our website TruckSkin.com Please contact us with any questions.

More information

LUCEN 2x2 ARCHITECTURAL RECESSED LUMINAIRE

LUCEN 2x2 ARCHITECTURAL RECESSED LUMINAIRE Project Name Date Type ARCHITECTURAL RECESSED LUMINAIRE 3-3/4 (95.3mm) 23-3/4 (603.3mm) 23-3/4 (603.3mm) Pre-painted formed 22 gauge cold rolled steel housing Highly reflective die-formed white painted

More information

SECTION 5 PARTS LISTS & EXPLODED VIEWS

SECTION 5 PARTS LISTS & EXPLODED VIEWS Model 506 (UC Ice Maker) Parts Lists & Exploded Views SECTION 5 PARTS LISTS & EXPLODED VIEWS 5-1 #3752200 - Revision B - May, 2006 Parts Lists & Exploded Views Model 506 (UC Ice Maker) 506 CABINET, LINER

More information

ULTIMA Natural Gas/LPG

ULTIMA Natural Gas/LPG Issue A May 2001 IPL Part # 788894 FREESTANDING GAS FIRES ULTIMA Natural Gas/LPG Part Numbers Natural Gas Black 988894 LPG Black 988895 From Serial Number 4007338 Issue A May 2001 IPL Part # 788894 Determine

More information

Avenue B. Grid Mount (Regress Trim Shown) Flush Lens. Drywall Flange (Regress Trim Shown) Narrow 3" slot LED with frosted satin lens.

Avenue B. Grid Mount (Regress Trim Shown) Flush Lens. Drywall Flange (Regress Trim Shown) Narrow 3 slot LED with frosted satin lens. LED corrugated regress trim solid regress trim flush lens DIMENSIONAL DATA Grid Mount (Regress Trim Shown) FEATURES Narrow 3" slot LED with frosted satin lens. Shielding options include corrugated or solid

More information

Installation instructions for the LUX LED-GYM WAVE

Installation instructions for the LUX LED-GYM WAVE Installation instructions for the LUX LED-GYM WAVE LUX WAVE 5 BAR LUX dynamics luminaires install in ¼ the time. It s a bold statement, but it s the truth. We do all the work for you. Simply snap on the

More information

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER. SAFETY Your safety and the safety of others is very important. In order to help you make informed decisions about safety, we have provided installation instructions and other information. These instructions

More information

Distribution Design Catalogue

Distribution Design Catalogue Distribution Design Catalogue Running Earth and Street Light Feed Section 03 (RE) Copyright of Western Power ABN 18540492861 RE Drawings Revision List CU DATE REVISION OF REVISION Sept 2002 Original Issue

More information

BarnCraft Rolling Door Product Guide Effective June 2016 Contact Us Phone: Hours of Operation

BarnCraft Rolling Door Product Guide Effective June 2016 Contact Us Phone: Hours of Operation BarnCraft Rolling Door Product Guide Effective June 2016 barnz.com This product guide includes product information for the rolling products included in our 2016-17 BarnCraft Premium Rolling Door catalog.

More information

Spring Steel Fasteners

Spring Steel Fasteners Conduit Supports 1 Available for 3/8 No tools needed! in. through 2 in. Finger friendly trade sizes for design! EMT, flexible conduit and MC/ AC cable Available with either a plain hole for 1/4 in. bolt

More information

WOOD FIRES VERONA NZ AUST. Verona Black Page 2

WOOD FIRES VERONA NZ AUST. Verona Black Page 2 Issue A April 2004 REF # 795956 WOOD FIRES VERONA NZ AUST Verona Black 995956 995956 Page 2 Fans Fan Assy-3 Speed - DE 995370 995370 Page 6 Fan Assy-Remote Control 998398 998398 Page 7 Flue 150mm Hi Therm

More information

600 SERIES STANDARD DUTY STRAIGHT TRACK INSTALLATION INSTRUCTIONS

600 SERIES STANDARD DUTY STRAIGHT TRACK INSTALLATION INSTRUCTIONS 600 SERIES STANDARD DUTY STRAIGHT TRACK INSTALLATION INSTRUCTIONS PLEASE READ INSTRUCTIONS THOROUGHLY BEFORE BEGINNING. A. BI-PARTING TRAVEL 1. Before raising track into position, determine location of

More information

Pipe Hangers. 47 B-Line series Pipe Hangers & Supports

Pipe Hangers. 47 B-Line series Pipe Hangers & Supports Pipe hangers offered in this section are designed to support insulated or non-insulated pipe allowing for vertical adjustment and limited movement in the piping system. Materials arbon Steel, Malleable

More information

TELETOM PREINSTALLATION MANUAL

TELETOM PREINSTALLATION MANUAL TELETOM PREINSTALLATION MANUAL MANUAL ORGANIZATION SAFETY CONTENTS SECTION 1 INTRODUCTION...1-1 DESCRIPTION...1-1 PRE-INSTALLATION RESPONSIBILITIES...1-2 BERCHTOLD RESPONSIBILITIES...1-2 OWNER RESPONSIBILITIES...1-3

More information

Internal Joist Mount: ACC120. extension column. Cathedral Ceiling Adapter: ACC556. Mounts to cathedral or vaulted ceilings 120 (+60 ) of adjustment

Internal Joist Mount: ACC120. extension column. Cathedral Ceiling Adapter: ACC556. Mounts to cathedral or vaulted ceilings 120 (+60 ) of adjustment Ceiling Plates Ceiling Plate: CMJ470(W), CMJ480(W), CMJ490(W) Internal Joist Mount: ACC120 Round Ceiling Plate: ACC570(S)(W), ACC571 Mounts to wood joists or structural concrete ceiling (requires concrete

More information

Electrical Accessories

Electrical Accessories complete system of top quality, time saving products, designed for surface metal raceways, lighting and cable supports. Innovative designs offer many installation advantages. -Line s surface raceways are

More information

BALTIMORE Natural Gas / LPG

BALTIMORE Natural Gas / LPG Issue G February 2002 IPL Part # 791906 FREESTANDING GAS FIRES BALTIMORE Natural Gas / LPG (New Zealand/Australia - ACC - Flued) Part Numbers - Natural Gas Black 991906 - LPG Black 991907 From Serial Number

More information

RIM Hood For Aeromaster Bodies

RIM Hood For Aeromaster Bodies RIM Hood For Aeromaster Bodies Service Guide WARNING: Hood should be opened by releasing the hold-down straps, lifting the hood, and engaging the prop rod. Be sure prop rod is properly engaged before working

More information

SANTA FÉ Natural Gas / LPG

SANTA FÉ Natural Gas / LPG Issue C March 2005 REF # 791922 FREESTANDING GAS FIRES SANTA FÉ Natural Gas / LPG New Zealand/Australia - Flueless Santa Fé Natural Gas Black 991922 Page 2 LPG Black 991923 Page 2 Fan Fan Assy-3 Speed

More information

FIGURE 1-1. CAB Operator Station. OCT/ D-1-1, Page 1

FIGURE 1-1. CAB Operator Station. OCT/ D-1-1, Page 1 FIGURE 1-1. CAB Operator Station OCT/2008 76D-1-1, Page 1 FIGURE 1-2. CAB Cab Accessories OCT/2008 (96760238) 76D-1-2, Page 1 FIGURE 1-4. OPERATOR STATION Cab Doors and Windows S/N 760163 and Above MAY/04

More information

HSpecialties Inc. TABLE OF CONTENTS

HSpecialties Inc. TABLE OF CONTENTS TABLE OF CONTENTS Introduction... Curtain Track Selection Guide...2 Ordering COMPLETE Tracks...3 00 Series Standard-Duty Straight Track...4 200 Series Black Medium-Duty Straight Track...8 300 Series Standard-Duty

More information

CLEANROOM PRODUCTS FLUSH HEPA GRID WITH INTEGRAL LIGHTING PLENUM MODULES CUSTOM AIR HANDLERS PLENUM MODULES FAN POWERED PLENUM MODULES

CLEANROOM PRODUCTS FLUSH HEPA GRID WITH INTEGRAL LIGHTING PLENUM MODULES CUSTOM AIR HANDLERS PLENUM MODULES FAN POWERED PLENUM MODULES TOP LOAD FLUSH GRID BOTTOM LOAD FLUSH GRID FLUSH HEPA GRID WITH INTEGRAL LIGHTING TOP LOAD FLUSH HEPA CEILING GRID BOTTOM LOAD FLUSH HEP CEILING GRID 34 & 316 BOTTOM LOAD FLUSH PLENUM MODULES PLENUM MODULES

More information

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility 43" Bridge Pit 44 1/2" 1130 175'-0" 53340 8 Spaces @ 75" = 50'-0" 15240 6'-3" 40" 105 1016 (typ.) 22 Spaces @ 37 1/2" = 68'-" 2055 12" 4877 Spaces @ 75" = 56'-3" 17145 35" 88 1 2 3 4 5 6 7 8 11 13 15 17

More information

Luminaire Support Location Cable Mounting Kit. Non-Power Feed

Luminaire Support Location Cable Mounting Kit. Non-Power Feed INSTALLATION INSTRUCTIONS These installation instructions are used for installing the following luminaires and kits: Luminaire Support Location Cable Mounting Kit OLE4 (suspended) Normal Power Feed Non-Power

More information

WOOD FIRES VERONA NZ AUST. Verona Black Page 2

WOOD FIRES VERONA NZ AUST. Verona Black Page 2 Issue A April 2004 REF # 795956 WOOD FIRES VERONA NZ AUST Verona Black 995954 995956 Page 2 Fans Fan Assy-3 Speed - DE 995370 995370 Page 6 Fan Assy-Remote Control 998398 998398 Page 7 Flue 150mm Hi Therm

More information

Linear Slot Diffusers Model Slot 20 & Model Slot 25

Linear Slot Diffusers Model Slot 20 & Model Slot 25 Model Slot & Model Slot 25 Contents Introduction!!!!!! Page 3 Di"user Specification!!!! Page 4 Air Patterns!!!!!! Page 5 Flange Styles!!!!!! Page 6 Corner Sections!!!!! Page 7 Selection Procedure!!!! Page

More information

SLIDING GLASS DOOR - NON-IMPACT

SLIDING GLASS DOOR - NON-IMPACT SLIDING - GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA UILDING CODE (FC), CURRENT EDITION. 2. GLAZING OPTIONS: (SEE ) 100 SW TH AVE. 3. APPROVED CONFIGURATIONS

More information

LAWN TRACTORS ELECTRIC CLUTCH HYDRO DRIVE SERIES F

LAWN TRACTORS ELECTRIC CLUTCH HYDRO DRIVE SERIES F Parts Manual for LAWN TRACTORS ELECTRIC CLUTCH HYDRO DRIVE SERIES F MODELS LT160H42FBV LT160H42FBV2 LT180H48FBV2 IT IS THE POLICY OF SNAPPER TO IMPROVE ITS PRODUCTS WHENEVER IT IS POSSIBLE AND PRACTICAL

More information

Pipe Hangers. Pipe Hangers. Pipe Hangers & Supports

Pipe Hangers. Pipe Hangers. Pipe Hangers & Supports Pipe hangers offered in this section are designed to support insulated or non-insulated pipe allowing for vertical adjustment and limited movement in the piping system. Materials arbon Steel, Malleable

More information

R & S Manufacturing and Sales Company

R & S Manufacturing and Sales Company R & S Manufacturing and Sales Company KNOCKED DOWN RIDGE VENTS RV9-12 ASSEMBLY INSTRUCTIONS April 2013 PARTS LIST End Caps (2 per vent) Wind Bands (2 per vent) Skirt Flashings (2 per vent) Skirt Cross

More information

SolarSheat Wall Installation Manual

SolarSheat Wall Installation Manual SolarSheat Wall Installation Manual Version 3.2 December 15, 2015 Copyright 2015 Your Solar Home, All Rights Reserved SolarSheat products must be installed in accordance to all local building, plumbing,

More information

229 B-Line series Pipe Hangers & Supports

229 B-Line series Pipe Hangers & Supports accessories offered in this section are designed to reduce installation time. wide range of types and sizes are available for various applications. Materials For maximum loading design, Carbon Steel, Forged

More information

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Active Chilled Beam Linear ACBL Series v11 Issue Date: 4/1/18 218 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Before You Start...1 Maintenance...1

More information

2,000 LB. CAPACITY S-20 - BTR HUB GROUP

2,000 LB. CAPACITY S-20 - BTR HUB GROUP 2,000 LB. CAPACITY S-20 - BTR HUB GROUP STANDARD GREASE LUBE PARTS HUBS Item Part # Description Item Part # Description Bolt Circle 602 Bearing Kit - 1 Hub 25 8-441 Plain Hub - tapped 4 on 4.00 1 10-9

More information

Specialties Inc. DISCLAIMER TABLE OF CONTENTS

Specialties Inc. DISCLAIMER TABLE OF CONTENTS TABLE OF CONTENTS Curtain Track Selection Guide...2 Ordering COMPLETE Tracks...3 Recommended Track Hanger Spacing...4 100 Series Standard-Duty Straight Track...6 200 Series Black Medium-Duty Straight Track...10

More information

FORM NO XLE LAWN TRACTOR. Model No & Up. Parts Catalog

FORM NO XLE LAWN TRACTOR. Model No & Up. Parts Catalog FORM NO. 3319 769 1232XLE LAWN TRACTOR Model No. 71201 8900001 & Up Parts Catalog 3319 769 ORDERING REPLACEMENT PARTS To order replacement parts, please supply: the part number, the quantity, and the description

More information

»Product» Safety Warning

»Product» Safety Warning #C9355 Installation Instructions 1999-2000 Chevy/GM 1500 2/4wd 3" Body Lift Kit Read and understand all instructions and warnings prior to installation of product and operation of vehicle. 1. Zone Offroad

More information

Delridge. Fremont. Highlands. Montlake. Eastlake. Newcastle

Delridge. Fremont. Highlands. Montlake. Eastlake. Newcastle Delridge Fremont Highlands Montlake Eastlake Newcastle Contents Ravenna ONCE YOU DO THE MATH. FOUR TIMES THE SELECTION DESIGNS: Eastlake Horizontal Panels Vertical Panels Combination Horizontal/Vertical

More information

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER. SAFETY Your safety and the safety of others is very important. In order to help you make informed decisions about safety, we have provided installation instructions and other information. These instructions

More information

Project Name. 23-5/8 (600.2mm)

Project Name. 23-5/8 (600.2mm) LiFT 2x2 Project Name Date Type ARCHITECTURAL RECESSED LUMINAIRE 23-5/8 (600.2mm) 23-5/8 (600.2mm) 5-5/8 (143mm) Formed 20 gauge cold rolled steel housing Highly reflective die-formed white painted reflector

More information

»Product» Safety Warning

»Product» Safety Warning Read and understand all instructions and warnings prior to installation of product and operation of vehicle. 1. Zone Offroad Products recommends this system be installed by a professional technician. In

More information

Universal Storage - Storage/Wardrobe/Combo Cabinets/Lateral Files

Universal Storage - Storage/Wardrobe/Combo Cabinets/Lateral Files Universal Storage - Storage/Wardrobe/Combo Cabinets/Lateral Files Storage Wardrobe Table of Contents Stack and Rotate Lateral File Combo Cabinet If you have a problem, question, or request, call your local

More information

2LP3GA217R-33FL-UNV-1/2-EBHE-LPT835HL

2LP3GA217R-33FL-UNV-1/2-EBHE-LPT835HL Recessed Project: Location: Cat.No: LP3 paralouver 2x2 Type: Lamps: Notes: Qty: 2 Lamp, T8, T5, or T5HO 9 or 16 cell The Philips Day-Brite / Philips CFI LP3 paralouver recessed is designed to provide the

More information

Applies to both UP & DOWN. Outputs between listed min and max are available. Consult factory for other lumen packages

Applies to both UP & DOWN. Outputs between listed min and max are available. Consult factory for other lumen packages Project Type Louver Notes Satin Ribbed Lens Spotless Lens PERFORMANCE PER LINEAR FOOT AT 35K (SR) 2 1/2" NOMINAL LUMEN OUTPUT INPUT WATTS EFFICACY DISTRIBUTION UP DOWN 8up/2down at 1 lm/ft 8 lm/ft 2 lm/ft

More information