1 PC-15x Counter-Balanced Backdraft Damper Product Bulletin Code No. LIT Issued April 7, 015 Refer to the QuickLIT Web site for the most up-to-date version of this document. Since 1885, Johnson Controls has developed and refined air control products by providing the highest quality control dampers that fit your application and size requirements. Now we are including counter-balanced backdraft dampers in our product offering. PC-150 Counterbalanced Backdraft Damper Low velocity Synthetic bearings PC-151 Counterbalanced Backdraft Damper Medium velocity Ball bearings PC-15 Counterbalanced Backdraft Damper High velocity Zytel bearings All three counter-balanced backdraft dampers feature zinc-plated weights. Figure 1: PC-15x Counterbalanced Backdraft Dampers Table 1: Features and Benefits Features 3-Year Warranty on Materials and Workmanship 15 to 5 Working-Day Standard Shipping after Order Entry Benefits Provides confidence in company-backed products. Results in fast response for short lead time projects. PC-15x Counter-Balanced Backdraft Damper Product Bulletin 1
2 Construction Table : Materials Part Materials Frame PC-150: x 1 in T5 extruded aluminum,.090 in. (.3 mm) wall thickness, mitered corners PC-151: 4 x 1 in T5 extruded aluminum,.081 in. (.1 mm) nominal wall thickness PC-15: -1/4 x 1 in T5 extruded aluminum,.15 in. (3. mm) wall thickness Blade PC-150: 0.05 in (.6 mm) formed aluminum with extruded vinyl edge seals PC-151 and PC-15: 6063-T5 extruded aluminum, 0.70 in. (1.8 mm) wall thickness with extruded vinyl edge Counterbalance Zinc-plated weights on blades. Adjustable for final on the job settings. Linkage Tie bars on blade Bearings PC-150: Synthetic PC-151: Dust proof, ball bearings pressed into frame PC-15: Zytel Finish Mill galvanized Sample Specification Furnish and install, at locations shown on plans or in accordance with schedules, counter-balanced backdraft control dampers meeting the following minimum construction standards: Damper frame must be minimum.090 in. (.3 mm) minimum wall thickness, 6063-T5 extruded aluminum with 1 gauge galvanized steel structural brace at each corner. shall be.05 in. (.6 mm) minimum roll-formed aluminum with extruded vinyl blade edge seals mechanically locked into blade edge. Adhesive or clip on type seals are unacceptable. shall include field adjustable, zinc-plated, steel counter-balance weights to allow pressure relief at less at.01 in. wg. Bearings must be corrosive resistant, long life synthetic type for quiet operation. Linkage must be 1/ in. (13 mm) wide tie bar, concealed in the frame. Dampers must be designed for maximum 1500 fpm spot velocities and up to 4 in. wg back pressure, depending on damper size. Dampers shall be in all respects equivalent to Johnson Controls PC-150 damper. Submittal data must include published leakage, pressure drop, and maximum pressure data based on Air Movement and Control Association International (AMCA) Standard 500 testing. Data must cover a full range of damper sizes; data from one size sample is not acceptable. PC-15x Counter-Balanced Backdraft Damper Product Bulletin
3 Damper Dimensions (51) 3 (76) (51) VERTICAL MOUNT HORIZONTAL AIR FLOW (51) Channel FRAME CONSTRUCTION 1 1/ (38) Typ. Front Flange Figure : PC-150 Damper Dimensions, in. (mm) A x B FIG: PC150dims.des 3/4 (70) Max. VERTICAL MOUNT HORIZONTAL AIR FLOW A* x B* 3 1/ (89) Max. FRAME CONSTRUCTIONS STANDARD 1 1/" (38) FLANGE (optional at additional cost) 1" (5) 3 3/8" (86) 4 1/8" (105) Figure 4: PC-151 Damper Dimensions, in. (mm) 1/4" (57) VERTICAL MOUNT HORIZONTAL AIR FLOW Width 1/4" (57) FRAME CONSTRUCTION 1 1/4" (3) Typ. A x B Channel Front Flange Figure 3: PC-151 Damper Dimensions, in. (mm) PC-15x Counter-Balanced Backdraft Damper Product Bulletin 3
4 Performance Curves Performance curves are based on AMCA Standard 500 using test setup apparatus figure 5.3 (damper installed with duct upstream and downstream). Static pressure and cubic feet per minute (cfm) are corrected to.075 lb/cu. ft air density. Table 3: Performance Data for PC-150 Model Damper Width, in. (mm) Maximum Back System Pressure - External Wind Velocity (in. wg) Maximum System Velocity (fpm) Leakage and Pressure Dampers may tolerate higher pressures and velocities than those listed in Table 3, Table 4, and Table 5. Conservative ratings are presented intentionally in an effort to avoid misapplication. Consult a Johnson Controls representative when a damper is to be applied in conditions exceeding recommended maximums. Leakage % of Maximum Flow 1 40 (1,016) 55 mph/1.5 in. wg 1, (914) 70 mph/.5 in. wg 1, (610) 85 mph/3.5 in. wg 1, (305) 95 mph/4.5 in. wg 1, Based on pressure differential of 1 in. wg Table 4: Performance Data for PC-151 Model Damper Width, in. (mm) Maximum Back System Pressure (in. wg) Maximum System Velocity (fpm) Leakage % of Maximum Flow 1 Total sq. ft/ cfm Total sq. ft/cfm Start to Fully 48 (1,19) 4.0 in. wg, in. wg.05 in. wg 36 (914) 8.0 in. wg, ( in. wg, (305) 16.0 in. wg, Based on pressure differential of 1 in. wg Table 5: Performance Data for PC-15 Model Damper Width, in. (mm) Maximum Back System Pressure (in. wg) Maximum System Velocity (fpm) Leakage % of Maximum Flow 1 Total sq. ft/ cfm Start to Fully 48 (1,19) 4.0 in. wg, in. wg.05 in. wg 36 (914) 8.0 in. wg, ( in. wg, (305) 16.0 in. wg, Based on pressure differential of 1 in. wg 4 PC-15x Counter-Balanced Backdraft Damper Product Bulletin
5 Figure 4 shows the air leakage when the PC-151 damper is closed. Figure 5 shows the pressure drop for PC-151 and PC-15 damper models. Note: Ratings are based on AMCA Standard 500 using Test Setup Apparatus Figure 5.3 (damper is installed with ducts upstream and downstream). Static pressure and conversion velocities are corrected to lb/cu. ft air density. PC-150 Horizontal Mount - DOWN Horizontal Mount - UP PC-151 Figure 5: PC-151 Air Leakage (When Damper Closed) Horizontal Mount - DOWN Horizontal Mount - UP PC-15 Horizontal Mount - DOWN Horizontal Mount - UP FIG: upflw.des Figure 6: Pressure Drop Chart (4 x 4 in.) for Models PC-151 and PC-15 Figure 7: Counter-Balanced Backdraft Damper by Damper Model PC-15x Counter-Balanced Backdraft Damper Product Bulletin 5
6 Ordering Information Table 6: PC-15x Industrial Dampers Code Number/Character Product Family Blade Operation Blade Type Bearing/ Seal Type Actuator Type Width Dimensions Height Dimensions Options (Limit ) P = Backdraft/Pressure Relief C = Counter-Balanced H = High Pressure (PC-15) L = Low Pressure (PC-150) M = Medium Pressure (PC-151) N = See Table. N = Normal ALL = 006 through 099 inches 1 inch increments PC-150 = 007 through 099 inches PC-151 = 011 through 099 inches PC-15 = 010 through 099 inches 1 inch increments E = Exact Size F = Front Flange (Air Leaving Side) G = Rear Flange (Air Entering Side) U = Upward Flow Maximum Single Panel Sizes FIELD Ordering Code Number P C L N N - w w w x h h h - - Table 7: Maximum Single Panel Sizes Damper Model Maximum Selection Size PC W x 48 in. H (1,016 x 1,19 mm) PC W x 5 in. H (1,19 x 1,31 mm) PC W x 5 in. H (1,19 x 1,31 mm) 6 PC-15x Counter-Balanced Backdraft Damper Product Bulletin
7 Installation Items Needed nut driver, 5/16 inch socket hammer hole saw, 1-1/4 inch drill bit, 3/16 inch (5 mm), No. 9 or 10 drill No. 1 self-tapping or No machine screws Technical Specifications PC-15x Counter-Balanced Backdraft Dampers 1. Install with frame square. Do not twist or rack the frame square. Use shims between the damper frame and the opening or duct to prevent distortion of the frame square.. Multiple section assemblies must be fastened together on the top, bottom, and all sides. Use appropriate bracing at every horizontal mullion and vertical bracing every 8 feet of damper width. 3. To complete the operation, position blade counter balance weights to set the desired blade opening pressure. 4. For fan discharge applications, locate the damper at least half the fan diameter from fan discharge. Isolation from excessive fan vibration is recommended. Maximum System Pressure PC-150 See Figure 3. PC-151 See Figure 4. PC-15 See Figure 5. Maximum System Velocity PC-150 1,000 feet per minute (305 m per minute) PC-151 and,500 feet per minute (76 m per minute) PC-15 Maximum Temperature -40 F (-40 C) minimum and 00 F (93 C) maximum Shipping Weight PC lb/sq. ft (17. kg/sq. ft) PC lb/sq. ft (17.3 kg/sq. ft) PC lb/sq. ft (17.7 kg/sq.ft) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication and misuse of its products. Building Efficiency 507 E. Michigan Street, Milwaukee, WI 530 Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 015 Johnson Controls, Inc. 7 PC-15x Counter-Balanced Backdraft Damper Product Bulletin Published in U.S.A.
ID-141x 12-Gauge Hat Channel Industrial Damper
ID-141x 12-Gauge Hat Channel Industrial Damper Product Bulletin Code No. LIT-12011355 Issued June 12, 2013 Supersedes March 13, 2012 Since 1905, Johnson Controls has developed and refined air control products
More informationRM-1200 Slim Round Control Damper
RM-1200 Slim Round Control Damper Product Bulletin Code No. LIT-12011358 Issued June 16, 2008 Since 1905, Johnson Controls has developed and refined air control products by providing the highest quality
More informationBD-1600 Balancing/Zone Control Damper
BD-1600 Balancing/Zone Control Damper Product Bulletin Code No. LIT-12012355 Issued September 2016 Refer to the QuickLIT website for the most up-to-date version of this document. The BD-1600 Balancing/Zone
More informationRA-2000 Airflow Measuring System
RA-2000 Airflow Measuring System Product Bulletin Code No. LIT-1201677 Issued May 2016 Refer to the QuickLIT website for the most up-to-date version of this document. Since 1905, Johnson Controls has provided
More informationSD-1250 and SD-1600 Series Smoke Dampers
SD-1250 and SD-1600 Series Smoke Dampers Product Bulletin Code No. LIT-1201592 Issued January 30, 2014 Supersedes October 14, 2013 Johnson Controls provides a leakage-rated damper for life safety smoke
More informationRD-2000 Round Control Dampers
RD-000 Round Control Dampers Product Bulletin Code No. LIT-8105 Issued February 5, 010 Supersedes July, 009 Johnson Controls provides top-quality, low-leakage RD-000 Round Control Dampers for use in Heating,
More informationAD-1250 Airflow Measuring Station
AD-1250 Airflow Measuring Station Product Bulletin Code No. LIT-12011472 Issued March 2016 Refer to the QuickLIT website for the most up-to-date version of this document. The AD-1250 Airflow Measuring
More informationCONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7
CONTROL DAMPERS MODEL 1380 HIGH PERFORMANCE ACKDRAFT DAMPER EXTRUDED ALUMINUM HEAVY DUTY Model 1380 is a high performance extruded aluminum gravity operated backdraft damper for use in medium to heavy
More informationVD-1600 Series Volume Control Dampers
VD-1600 Series Volume Control Dampers Product Bulletin VD-1600 Code No. LIT-1201735 Issued April 2017 Refer to the QuickLIT website for the most up-to-date version of this document. Since 1885, Johnson
More informationCONTROL DAMPERS. Models 1810 & Model Model Model 1370
CONTROL DAMPERS CONTROL DAMPERS MODELS 1810 & 1820 MANUAL ALANCING DAMPERS STEEL Models 1810 and 1820 have been engineering and designed for manual balancing applications in low to medium pressure and
More informationAD-1251 Probe with Differential Pressure Transducer
AD-1251 Probe with Differential Pressure Transducer Product Bulletin Code No. LIT-12011473 Issued October 31, 2011 Supersedes September 6, 2011 The AD-1251 Probe with Differential Pressure Transducer (DPT)
More informationIntroduction to Johnson Controls Dampers
Damper and Actuator Product Guide 268.1 Damper Engineering Section Product Bulletin Issue Date 1297 Introduction to Johnson Controls Dampers For over 100 years, Johnson Controls has been the industry leader
More informationModel VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options
Application and Design The series is a general purpose, low leakage control damper intended for application in low pressure and velocity systems. atings Pressure: 2 in. wg (.5 kpa) - pressure differential.
More informationWD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.
Application and Design The WD300 series dampers are designed to prevent reverse airflow in horizontal exhaust applications. The WD300 features a pressure sensitive blade design that opens and remains open
More informationControl Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers
Control s Model FDCB (Opposed Blade) FDHB (Parallel Blade) Aluminum Low Leakage Control s Frame:.081 extruded aluminum Blades:.125 extruded aluminum Bearings: bronze oilite Linkage: *concealed in frame
More informationVCD-23. Flange Options. Size Limitations
Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators
More informationHCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.
Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety
More informationPositive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS
BACKDRAFT DAMPERS BLADE OPTION: SR: 0.016-0.020 roll formed aluminum with vinyl gasket - used with fan motors under 1 HP SE: 0.05 extruded aluminum with vinyl gasket - used with fan motors over 1 HP Positive
More informationHCD-230 Industrial Control Damper
Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety
More informationWD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.
Application The WD200 series are electrically motorized backdraft dampers that open when energized and spring return close when deenergized. The WD200 series are for horizontal or vertical mounting. Primary
More informationSP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type
1 SUBMITTAL DATA Series 1000 Air-Foil Control Damper SP Standard Profile 2" 50.8 mm In Duct or Flanged to Duct Install Types 4" 101.6 mm 6.4" 162.6 mm blades fully open 1" 25.4 mm Extended Rear Flange
More informationModel VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options
Application The series is a general purpose control damper for applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. A wide range of electric
More informationAMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options
Application and Design Thermal Dispersion Air Measuring Station with VCD-42 Control Damper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage
More informationVCD-23. Low Leakage CONTROL DAMPER
Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators
More informationBaked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)
Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure
More informationAMD-42V Air Measuring Station with VCD-42V Control Damper
Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) 14 ga. (2mm) Frame Type 5 in. x 1 in. hat channel - Blade
More informationAMD-42 Air Measuring Station with VCD-42 Control Damper
Application and Design W x H Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness External Minimum Size 16 ga. (1.5mm) Internal Single Section Maximum Size Multiple
More informationModel VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.
Model Application The is a low leakage high performance control damper with extruded aluminum airfoil blades. Blades are completely contained within the frame allowing the damper to be directly mounted
More informationM Remote Mounting Kit
M9203-250 Remote Mounting Kit Installation Instructions M9203-250 Part No. 34-636-2324, Rev. Issued July 6, 2011 Applications The M9203-250 Remote Mounting Kit enables the M9203 Series Electric Spring
More informationVCD-23 Low Leakage CONTROL DAMPER
Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric actuators are available.
More informationModel VCD-20 3V CONTROL DAMPER
R Application and Design The series is a ruggedly built general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium
More informationCentrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved
Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability
More informationInsulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)
R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken blade to eliminate the transfer of heat or cold penetration and reduced
More informationAIR CONDITIONING PRODUCTS COMPANY
Quality Products for Motorized Dampers AIR CONDITIONING PRODUCTS COMPANY Wall Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga ble Shutter Drainable Louver Supply Damper Fiberglass
More informationCentrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved
Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the
More informationModel DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating
Application Model is a multi-blade fire damper with 3V style blades. The has been qualified to 4000 fpm (20.3 m/s) and 10 in. wg (2.5 kpa) for dynamic closure in emergency fire situations. Model may be
More informationARROW INDUSTRIAL PRODUCTS
IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products
More informationFiltered Kitchen Supply Packaged Ventilator
Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................
More informationInsulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.
R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and
More informationSafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )
( Flange Type ) SPK 30-100 Standard Construction FRAME: 160mm x 30mm x 1.5mm (16 Ga.) galvanized steel formed channel for flange connection. BLADES: 250mm max. width, 1.5mm (16 Ga.) galvanized steel. FINISH:
More informationInsulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel
Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and
More informationDimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty
Submittal Data Model PELV-100 Penthouse Elevator Vented Hood Application and Design The PELV-100 Penthouse Elevator Vented Hood is a gravity ventilator penthouse with an 18" x 18" gasketed access door
More informationThermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed
Application The is a low leakage thermally insulated damper with extruded airfoil blades. features broken blade which minimized the transfer of thermal energy and reduce condensation. It s also IECC (International
More informationRA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System
RA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System Product Bulletin Code No. LIT-12011620 Issued July 2, 2014 RA-1250 Thermal Dispersion Fan Inlet Sensor Airflow Measuring System averages
More informationFBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.
Application and Design The is a vertical style face and bypass low leakage damper. This model is intended for application in medium to high pressure and velocity systems. Smooth profile extruded aluminum
More informationM Ball Valve Linkage Kit
M9000-551 Ball Valve Linkage Kit Installation Instructions Part No. 34-636-1816, Rev. B Issued July 6, 2011 Supersedes February 7, 2006 Applications The M9000-551 Ball Valve Linkage Kit (Figure 1) is designed
More informationAMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers
AMCA MEMBER American Warming and Ventilating A Mestek Company Quality Air Control Dampers Over a century of dedication to quality products and customer satisfaction has enabled American Warming and Ventilating
More informationThermal Isolation. Break
Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade will minimize the transfer of thermal energy and reduces condensation.it
More informationVCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:
Application and Design is a low leakage damper with vertical blade orientation designed to meet the highest standards established for commercial control dampers. The is intended for application in medium
More informationAMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options
Application and Design The combines the functionality of an accurate airflow measuring station and a low leakage control damper into one compact assembly that both measures and regulates airflow volumes
More informationAMD-33 Air Measuring Station with VCD-33 Control Damper
Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized
More informationModel VCD-43 Extruded Airfoil Blade Control Damper
Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure
More informationAMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options
Application Thermal Dispersion Air Measuring Station with VCD-23 Control Damper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage control
More informationMODEL OAL. Water Penetration. Water Penetration. Free Area OAL PERFORMANCE REGISTERS GRILLES &
MODEL OAL The OAL series of etruded aluminum stationary louvers is manufactured for installation in eterior wall openings. They are designed to allow fresh air and ehaust air to flow into/out of the building
More informationGRAVITY INTAKE AND EXHAUST ROOF VENTILATORS
GRAVITY INTAKE and EXHAUST ROOF VENTILATORS SECTION 21 GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS Series GE and GI Low Silhouette This attractive low silhouette design is available in specific versions
More informationTED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 APPLICATION Ruskin model TED50XT is a low leak, thermally efficient damper with insulated extruded aluminum blades specially
More informationM9000-3xx Series Weather Shield Enclosures
M9000-3xx Series Weather Shield Enclosures Product Bulletin Code No. LIT-1201704 Issued June 2016 Refer to the QuickLIT website for the most up-to-date version of this document. The M9000-3xx Weather Shield
More informationGRAVITY VENTILATORS SIZING
GRAVITY VENTILATORS SIZING RCXII (sizes 6-20) RCXII (sizes 24-36) RCXII-SF BGH RLX Sizing The tables shown offer quick selections at common static pressure points. Selection choices vary widely due to
More informationINLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK
INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS Air Zoë Centrifugal Inline Duct fans have been developed to efficiently handle the
More informationModel VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.
Application and Design The series is a vertical blade general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium
More informationInstallation Instructions
34-636- 2286, Rev. C (barcode for factory use only) M9000-400 Jackshaft Linkage Kit Installation Instructions M9000-400 Part No. 34-636-2286, Rev. C Issued June 2017 Applications Refer to the QuickLIT
More informationModel CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I
Application and Design Model is a combination fire smoke damper that is UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model s operational ratings
More informationD-4070 Two Stage Pneumatic Actuator
FANs 268.1, 1628.3 Product/Techncial Bulletin D4070 Issue Date 1095 D-4070 Two Stage Pneumatic Actuator The D-4070 Two Stage Pneumatic Actuator is a multipurpose positioning device used to accurately position
More informationHorizontal and Vertical Belt Drive Blower Coil Units (Models AHI and AVI)
Technical Bulletin Issue Date December 6, 2004 Horizontal and Vertical Belt Drive Blower Coil Units (Models AHI and AVI) Model AHI Horizontal and Model AVI Vertical Belt Drive Blower Coils are designed
More informationM x Series Cast Iron Flanged Valve Linkage Kit for M9000 Series Electric Actuators
Product Bulletin 53x Series Issue Date April 4, 2014 Supersedes June 19, 2007 53x Series Cast Iron Flanged Linkage Kit for M9000 Series Electric s The 53x Series Cast Iron Flanged Linkage Kits are designed
More informationFADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.
January 2008 FADE0108 Fantech, Inc. certifies that the FADE Series shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA
More informationPP1 Series Piping Packages for VG1000 Series Ball Valves
PP Series Piping Packages for VG000 Series Ball s Product Bulletin PP2xxxxx- Series, PP8xxxxx- Series Code No. LIT-20974 Issued August, 204 PP Series Piping Packages are designed to provide an easier way
More informationTE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies
TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies Installation Instructions Part No. 24-4034-42, Rev. D Issued December 9, 2011 Supersedes August 1, 1997 Applications TE-6100
More informationSafidDampers SPK Description. Standard Construction SPK ( Flange Type )
( Flange Type ) SPK 30-300 Description SPK 30 - Series The single and multi-leaf s with extruded aluminum airfoil blades are designed for quite, efficient and reliable air volume control in air conditioning
More informationModel VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations
Application and Design The series is an ultra low leakage damper with rugged steel airfoil blades designed to meet the highest standards established for commercial control dampers. The airfoil shape reduces
More informationCONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc.
Nailor Industries Inc. CONTROL & ACKDRAFT DAMPERS 1 Contents Page No. Product Overview 4 Features of Nailor Control Dampers 1 Standard Performance Control Dampers Models 11/12 Low Leakage Vee-lades 11
More informationFor installation into ductwork
X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum
More informationSECTION CONTROL DAMPERS
SECTION 23 09 13.43 - CONTROL DAMPERS PART I - GENERAL 1.1 SECTION INCLUDES A. Airfoil Dampers, Heavy Duty Galvanized Steel B. Thermally Insulated Dampers, Heavy Duty Galvanized Steel C. Airfoil Dampers,
More informationVOLUME CONTROL DAMPERS
VOLUME CONTROL DAMPERS CONSTRUCTION FEATURES FRAME Roll formed 16 gauge galvanized steel channel with welded corners. X-Standard, Z-optional AXLES Roll formed 18 gauge galvanized steel. 1/2" Round chrome
More informationA. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES
SECTION - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this
More informationDAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING
PUB. NO. 732-3 DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING The most widely used dampers in commercial HVAC applications Control Dampers - Extruded Aluminum
More informationModel VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.
Application and Design The Series is a ruggedly built low leakage control damper with thermally insulated blades. The is intended for application in medium pressure and velocity systems. This model also
More informationBULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven
BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the
More informationCentrifugal Cabinet Fans Model BCF Belt Drive Low-Profile
Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or
More informationARROW UNITED INDUSTRIES
IP-3R ARROW UNITED INDUSTRIES Building Tomorrow s Ventilation Today Heavy Duty Dampers Industrial, Power Plant & Commercial Applications ARROW UNITED INDUSTRIES has specialized in the design and manufacturing
More informationCentrifugal Filtered Supply Roof Blowers
CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................
More informationAIR DUCT ACCESSORIES
SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 GENERAL 1.1 SUMMARY A. Work included: 1. Sheet Metal Materials 2. Backdraft Dampers 3. Dampers 4. Concealed Damper Hardware 5. Access Doors 6. Duct Test Holes
More informationAMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty
MODEL FEATURES Exhaust air up to 2,800 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space is limited Non-overloading
More informationVertical Hi-Rise Fan Coil Unit (Model FS)
Technical Bulletin Issue Date March 1, 2005 Vertical Hi-Rise Fan Coil Unit (Model FS) Model FS Vertical Hi-Rise fan coil units are designed to maximize flexibility of selection and installation. The units
More informationSeries Y63, Y64, Y65, Y66, and Y69 Transformers
Product/Technical Bulletin Issue Date December 17, 2002 Series Y63, Y, Y65, Y66, and Y69 Transformers The series Y63, Y, Y65, Y66, and Y69 transformers handle 24 power requirements from 40 VA through 300
More informationM x Series Cast Iron Flanged Valve Linkage Kit for Tandem Mounting of M9000 Series Electric Actuators
Issue Date June 15, 2007 Supersedes November 15, 2002 M9000-53x Series Cast Iron Flanged Valve Linkage Kit for Tandem Mounting of M9000 Series Electric Actuators Installation Parts Included Linkage Stem
More informationVANEAXIAL & TUBEAXIAL FANS
BULLETIN 482 July 2008 VANEAXIAL & TUBEAXIAL FANS Type "S" Belt Driven Featuring Welded Steel Propellers Models VSBD & TSBD Model TSBD Belt Driven Tubeaxial Type "S" Vaneaxial & Tubeaxial Fans For applications
More informationVertical Floor Fan Coil Unit (Model FW)
Technical Bulletin Issue Date March 24, 2005 Vertical Floor Fan Coil Unit (Model FW) Figure 1: Model FWX Vertical Exposed Model FW Vertical Floor fan coil units are designed to maximize flexibility of
More informationM9206-Bxx-2S Series On/Off Electric Spring Return Actuators
Installation Instructions M9206-Bxx-2S Issue Date May 14, 2003 M9206-Bxx-2S Series On/Off Electric Spring Return Actuators Installation IMPORTANT: Use this M9206-Bxx-2S Series actuator to control equipment
More informationSTATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS
STATIONARY LOUVERS 14 15 STATIONARY LOUVER STATIONARY LOUVER SSL - 100 SSL SERIES SSL SERIES [SSL - 100, SSL - 110, SSL - 120] Air Performance Pressure Drop SSL - 100 Stationary Louver is a weather louver
More informationM x Series Valve Linkage Kits
M9000-51x Series Valve Linkage Kits Installation Instructions M9000-51x Part No. 14-1201-13, Rev. G Issued October 16, 2008 Supersedes May 6, 2008 Applications Use the M9000-51x Series Valve Linkage Kits
More informationM x Series Valve Linkage Kits
Installation Instructions M9000-51x Issue Date 05/01/02 M9000-51x Series Valve Linkage Kits Installation Parts Included Quantity Description 1* Actuator Mounting Bracket 1* Adjustable Anti-Rotation Slider
More informationM x Cast Iron Flanged Valve Linkage Kit for Mounting a Single M9000 Series Electric Actuator
Installation Instructions Issue Date June 15, 2007 Supersedes November 15, 2002 M9000-53x Cast Iron Flanged Valve Linkage Kit for Mounting a Single M9000 Series Electric Actuator Installation Parts Included
More informationModel SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.
Model Application The is a leakage rated modulating smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper
More informationSeries HCD Airfoil Control Damper
Series HCD Airfoil Control Damper Model: HCD-1 The Holyoake HCD-1 is a precisely made volume and pressure control device with extremely low leakage when closed, (in the range of 0.003m 3 /s at 100 Pa).
More informationAFG501 ALUMINUM FEMA 361 LOUVER LOUVER TYPE RECOMMENDED SPECIFICATION
LOUVER TYPE AFG501 ALUMINUM FEMA 361 LOUVER Visible Mullion Louver Type... AFG501 Blade Material... Extruded Aluminum, Alloy 6061-T6 Blade... 0.25 in. (6.35 mm) Frame Material... Formed Aluminum, Alloy
More informationAIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT
ZONE INTERNATIONAL MIXED- COLUMN UNIT 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM ZONE INTERNATIONAL MIXED- COLUMN UNIT T DUCT COLLAR INLET (A x B) PRIMARY RETURN
More informationM Valve Actuator Weather Shield Kit
34-636- 2235, Rev. C M9000-341 Valve Actuator Weather Shield Kit Installation Instructions Part No. 34-636-2235, Rev. C Issued March 2016 Applications The M9000-341 Weather Shield Kit is a cost-effective
More informationR-317 Air Flow Controller
24-4660- 1, Rev. B Product Bulletin R-317 Issue Date February 2016 R-317 Air Flow Controller The R-317 Air Flow Controller is a proportional, direct acting, low volume output signal instrument designed
More informationM Damper Mount Linkage Kit Installation. Item Description Quantity Item Description Quantity Nuts 2
FANs 268.1, 1628.3 Installation Bulletin M9000-150 Issue Date 0796 M9000-150 Damper Mount Linkage Kit Installation 21 18 19 20 2 22 17 2 4 3 2 15.5 393.7 1 17 16 15 11 13 12 8 9 10 2 5 Note: Damper mount
More information