Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Size: px
Start display at page:

Download "Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I"

Transcription

1 Application and Design Model is a combination fire smoke damper that is UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model s operational ratings of 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) far exceed the air flows and pressure differences normally encountered when installed above grilles or diffusers in corridor ceilings - providing an extra measure of safety. is rated for airflow and leakage in either direction and can be used in vertical or horizontal installations. Ratings UL 555 Fire Resistance Rating Fire Rating: 1 hour Dynamic Closure Rating: Actual limits are size dependent Maximum Velocity: 2000 fpm (10.2m/s) Maximum Pressure: 6 in. wg (1.5 kpa) UL 555S Leakage Rating Leakage Class: I Operational Rating: Limits are actuator dependent Maximum Velocity: 2000 fpm (10.2 m/s) Maximum Pressure: 6 in. wg (1.5 kpa) Maximum Temperature: 350 F (177 C) - depending upon the actuator Construction Standard Optional Frame Material Galvanized steel - Frame Material 16 ga. (1.5mm) - Thickness Frame Type 5 in. x 1in. - (127mm x 25mm) hat channel Blade Material Galvanized steel - Blade Material 16 ga. (1.5mm) - Thickness Blade Type 3V - Linkage Plated steel out of 304SS airstream, concealed in jamb Axle Bearings Bronze 304SS Axle Material Plated steel 304SS Blade Seals Silicone - Jamb Seals 304SS - Closure Device RRL RRL/OCI, TOR, PRV, Fusible LInk Closure Temperature 165 F (74 C) 212 F (100 C), 250 F (121 C), 350 F (177 C) Minimum Size Maximum Size W x H Configuration Configuration Configuration Single Section Inches 12 x 12 8 x 6 8 x 6 24 x 24 mm 305 x x x x 610 Model Corridor FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I Model meets the requirements for corridor ceiling dampers, smoke dampers and combination fire/smoke dampers established by: National Fire Protection Association NFPA Standards 80, 90A, 92A, 92B, 101 & 105 IBC International Building Codes New York City (MEA Listing # M) CSFM California State Fire Marshal Listing #: :105, :106 UL CLASSIFIED (see complete marking on product) UL CLASSIFIED to Canadian safety standards (see complete marking on product) Standard 555 & 555S (Listing #R13317) H* model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only. * W & H dimensions furnished approximately 1 /4 in. (6mm) undersize. (Add sleeve thickness for overall sleeved damper dimension) Right hand drive is shown. Left hand drive is available upon request. Features: Frames are constructed with reinforced corners. Low profile head and sill are used on sizes less than 17 in. (432mm) high. Blades are reinforced with 3 longitudinal structurally designed vee's. Options: Actuators (120V, 24V, 230V, pneumatic) POC retaining angles Momentary or toggle test switches Sealed transition and sleeve Flanges Grille Tabs Greenheck Test Switches (GTS-1, -2, -3, -4) Transitions (R, C, O) Clean Wrap W* Installation instructions available at

2 pressure drop Data cfsd-211 This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of.075 lb/ft 3 (1.201 kg/m 3 ). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. 6D D 4 (W) (H) 3.14

3 AMCA 5.2 Figure 5.2 * * This size is based on multi-section unit. 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 12 in. x 48 in. (305mm x 1219mm) in. x 12 in. (1219mm x 305mm) model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only.

4 AMCA 5.3 6D * This size is based on multi-section unit. 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 12 in. x 48 in. (305mm x 1219mm) in. x 12 in. (1219mm x 305mm) model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only.

5 AMCA 5.5 * This size is based on multi-section unit. 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 12 in. x 48 in. (305mm x 1219mm) in. x 12 in. (1219mm x 305mm) model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only.

6 Configurations Space Envelopes is available in 3 different configurations to accommodate a variety of installation and access requirements. Drawings below illustrate these different configurations and their associated dimensions. Configuration #1 Fire Rated Is The Finished : Actuator (Internal Only) Accessible Through The Grille H Actuator Space Envelopes Honeywell ML-4XXX Series MS4209 Series in. (mm) Fire Rated X Grille (by others) 5 A Sleeve Length X Dimension 8 1/8 (206) Minimum Width 12 (305) Minimum Height 12 (305) Sleeve Length = Depth of Grille (or Register) + X (Actuator: see table above) + 5 in. [127mm] (Damper Width) + 11/4 in. [31.8mm] (for duct connection) (round up to nearest length: 16 in., 18 in., or 21 in. [406mm, 457mm, or 533mm] Sleeve Gauge = 16 Ga. (1.5mm) or 20 Ga. (1mm) Configuration #2 Fire Rated Is The Finished : Actuator (Internal or External) Accessible Above Finished H A Configuration #2 is for applications where the fire rated ceiling is the finished ceiling but where access to the damper actuator is available from above the finished ceiling. Actuators can be mounted internally or externally. Clearance must be maintained between damper and grille for proper operation. 5 Sleeve Length All dimensions shown are in inches (mm). Fire Rated Grille (by others) 4 3/4 Min. Minimum Size Internal : 12 in. x 12 in. (305mm x 305mm) When OCI, RRL, or TOR, H dimension less than 10 in. (254mm) 'A' Dimension Standard 12 (305) Minimum Sleeve Length 21 (533) All other dampers 7 3/16 (182) 16 (406) Configuration #3 H Fire Rated Is Above The Finished : Actuator (Internal or External) Accessible Through Finished Configuration #3 is for applications where the fire rated ceiling is above the finished ceiling. Actuators can be mounted internally or externally. Fire Rated Finished Below A Sleeve Length Minimum Size Internal : 12 in. x 12 in. (305mm x 305mm) When OCI, RRL, or TOR, H dimension less than 10 in. (254mm) All dimensions shown are in inches (mm). 'A' Dimension Standard 12 (305) Minimum Sleeve Length 21 (533) All other dampers 7 3/16 (182) 16 (406)

7 Specifications Corridor Fire Smoke Dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as described in schedules. Dampers shall meet the requirements of the latest edition of NFPA 80, 90A, 92A, 92B, 101 & 105. Dampers shall be tested, rated and labeled in accordance with the latest edition of UL Standards 555 and 555S. Dampers shall be classified by UL under the Corridor Damper listing with a UL 555 fire rating of 1 hour. Each damper shall be equipped with a heat responsive device which has been tested and approved for use with the damper assembly in accordance with UL 555. The heat responsive device shall have a temperature rating of (specifier select one of the following) 165 F (74 C), 212 F (100 C), 250 F (121 C), or 350 F (177 C). Dampers shall be UL labeled for use in dynamic systems. The damper shall have a dynamic closure airflow rating equal to or greater than the airflow at the damper s installed location and a dynamic closure pressure rating of 6 in. wg (1.5 kpa). Dampers shall have a UL 555S Leakage rating of Class I and a temperature rating of 250 F (121 C) minimum. Dampers shall have a UL 555S operational airflow rating equal to or greater than the airflow at its installed location and an operational pressure rating of 6 in. wg (1.5 kpa). Damper actuators must be factory mounted and qualified for use with the damper in accordance with UL 555S. Damper actuators shall be (specifier select one of the following) electric type for 120 (24 or 230) volt operation. Manufacturers submittal data shall indicate actuator space requirements around the damper. All UL 555 and 555S Dynamic Closure Ratings, Operational Ratings and Leakage Ratings shall be qualified for airflow and pressure in either direction through the damper. UL ratings shall allow for mounting damper vertically (with blades running horizontal) or horizontally. The Damper Manufacturers submittal data shall certify all air performance pressure drop data is licensed in accordance with the AMCA Certified Ratings Program for Test Figures 5.2, 5.3 and 5.5. Damper air performance data shall be developed in accordance with the latest edition of AMCA Standard 500-D. Dampers shall be labeled with the AMCA Air Performance Seal. Dampers shall be listed by the California State Fire Marshal. Dampers shall be listed by the New York City Department of Buildings Material and Equipment Acceptance (MEA). Damper blades shall be 16 ga. (1.5mm) galvanized steel 3V type with three longitudinal grooves for reinforcement. Blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow and operation in either direction through the damper (blades that are non-symmetrical relative to their axle pivot point or utilize blade stops larger than ½ in. (13mm) are unacceptable). Damper frames shall be galvanized steel formed into a structural hat channel shape with reinforced corners. Bearings shall be sintered bronze sleeve type rotating in extruded holes in the damper frame. Blade edge seals shall be silicone rubber designed to inflate and provide a tight seal against leakage as pressure on either side of the damper increases. Jamb seals shall be stainless steel compression type. Basis of design is Greenheck Model. Copyright 2011 Greenheck Fan Corporation Rev. 9 Aug 2011

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating Application Model is a multi-blade fire damper with 3V style blades. The has been qualified to 4000 fpm (20.3 m/s) and 10 in. wg (2.5 kpa) for dynamic closure in emergency fire situations. Model may be

More information

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations. Application Model is a leakage rated modulating smoke damper with 3V style blades. The has been qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operational closure in emergency smoke control

More information

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating R APPLICATION Model FSD-211 is a combination fire smoke damper with 3V style blades. The FSD-211 has been qualified to 2000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operation and dynamic closure in emergency

More information

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features Application Model is a high performance combination fire smoke damper with Class I leakage. High strength airfoil blades ensure the lowest resistance to airflow in HVAC systems with velocities to 4000

More information

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating R Model Application Model is a 304SS combination fire smoke damper with 3V style blades. The is qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa). This damper may be installed vertically (with blades

More information

Model FSD-331 Combination Fire Smoke Dampers

Model FSD-331 Combination Fire Smoke Dampers R APPLICATION Model is a high performance combination fire smoke damper with class I leakage. High strength airfoil blades ensure the lowest resistance to airflow in HVAC systems with velocities to 4000

More information

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations. Application Model is a leakage rated smoke damper with 3V style blades. The has been qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operational closure in emergency smoke control situations.

More information

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating. Application Model is a combination fire smoke damper with 3V style blades. This model is designed for operation and dynamic closure in emergency fire smoke situations. It is rated for airflow and leakage

More information

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations. Model Application The is a leakage rated modulating smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper

More information

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model FSD-212. Combination FIRE SMOKE DAMPERS R APPLICATION Model is a combination fire smoke damper with 3V style blades. The has been qualified to 2000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operation and dynamic closure in emergency fire smoke

More information

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features Model Application The is a leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper and smoke

More information

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options Application and Design The series is a general purpose, low leakage control damper intended for application in low pressure and velocity systems. atings Pressure: 2 in. wg (.5 kpa) - pressure differential.

More information

VCD-23. Flange Options. Size Limitations

VCD-23. Flange Options. Size Limitations Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators

More information

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options Application The series is a general purpose control damper for applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. A wide range of electric

More information

VCD-23 Low Leakage CONTROL DAMPER

VCD-23 Low Leakage CONTROL DAMPER Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric actuators are available.

More information

VCD-23. Low Leakage CONTROL DAMPER

VCD-23. Low Leakage CONTROL DAMPER Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators

More information

Model VCD-20 3V CONTROL DAMPER

Model VCD-20 3V CONTROL DAMPER R Application and Design The series is a ruggedly built general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium

More information

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178) Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure

More information

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options. Application and Design The series is a vertical blade general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium

More information

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation Application and Design The is a severe environment 316SS ultra low leakage control damper with rugged stainless steel airfoil blades designed to meet the highest standards established for commercial control

More information

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options. Application and Design The Series is a ruggedly built low leakage control damper with thermally insulated blades. The is intended for application in medium pressure and velocity systems. This model also

More information

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178) R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken blade to eliminate the transfer of heat or cold penetration and reduced

More information

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options. Model Application The is a low leakage high performance control damper with extruded aluminum airfoil blades. Blades are completely contained within the frame allowing the damper to be directly mounted

More information

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed Application The is a low leakage thermally insulated damper with extruded airfoil blades. features broken blade which minimized the transfer of thermal energy and reduce condensation. It s also IECC (International

More information

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-43 Extruded Airfoil Blade Control Damper Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure

More information

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-33 Air Measuring Station with VCD-33 Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized

More information

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options Application and Design The combines the functionality of an accurate airflow measuring station and a low leakage control damper into one compact assembly that both measures and regulates airflow volumes

More information

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in. R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and

More information

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options Application Thermal Dispersion Air Measuring Station with VCD-23 Control Damper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage control

More information

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations Application and Design The series is an ultra low leakage damper with rugged steel airfoil blades designed to meet the highest standards established for commercial control dampers. The airfoil shape reduces

More information

Thermal Isolation. Break

Thermal Isolation. Break Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade will minimize the transfer of thermal energy and reduces condensation.it

More information

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations. Application and Design The is a vertical style face and bypass low leakage damper. This model is intended for application in medium to high pressure and velocity systems. Smooth profile extruded aluminum

More information

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction. Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and

More information

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options Application and Design Thermal Dispersion Air Measuring Station with VCD-42 Control Damper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage

More information

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42V Air Measuring Station with VCD-42V Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) 14 ga. (2mm) Frame Type 5 in. x 1 in. hat channel - Blade

More information

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper Application and Design W x H Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness External Minimum Size 16 ga. (1.5mm) Internal Single Section Maximum Size Multiple

More information

HCD-230 Industrial Control Damper

HCD-230 Industrial Control Damper Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure: Application and Design is a low leakage damper with vertical blade orientation designed to meet the highest standards established for commercial control dampers. The is intended for application in medium

More information

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features Application Model is approved for use in walls, floors, and partitions with fire resistance ratings less than 3 hours. This model carries a 1 1 2 hour UL fire damper label. UL555 classifies dynamic rated

More information

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features Application Model is approved for use in walls, floors, and partitions with fire resistance ratings of hours or more. This model carries a hour UL fire damper label. UL 555 classifies dynamic rated fire

More information

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features Application Model is approved for use in walls, floors, and partitions with fire resistance ratings less than 3 hours. This model carries a 1 1 2 hour UL fire damper label. UL555 classifies dynamic rated

More information

Fusible Link (replaceable) Horizontal Mount

Fusible Link (replaceable) Horizontal Mount Application Model SSFD-50 is a static rated fire damper approved for use in walls and partitions with fire resistance ratings less than hours. This model carries a 2 hour UL fire damper label. UL555 classifies

More information

Fusible Link (replaceable) Horizontal Mount

Fusible Link (replaceable) Horizontal Mount Application Model FD-50 is a static rated fire damper approved for use in walls and partitions with fire resistance ratings less than hours. This model carries a /2 hour UL fire damper label. UL 555 classifies

More information

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional. Application Model FD-50 is a static rated fire damper approved for use in walls and partitions with fire resistance ratings of hours or more. This model carries a hour UL fire damper label. UL555 classifies

More information

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 FSD36, FSD36LP COMINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2 APPLICATION Ruskin FSD36 Series

More information

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations. Application and Design The WD300 series dampers are designed to prevent reverse airflow in horizontal exhaust applications. The WD300 features a pressure sensitive blade design that opens and remains open

More information

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 FSD60, FSD60LP CoMINAtIoN FIRe AND SMoKe DAMPeR 1 1 /2 HoUR UL555 RAteD, UL555S LeAKAge CLASS 1 APPLICAtIoN Ruskin FSD60 Series

More information

Motorized Fire Dampers

Motorized Fire Dampers Model : OMFD-611 (Fusible link and spring return actuator) GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Static and

More information

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper. Application The WD200 series are electrically motorized backdraft dampers that open when energized and spring return close when deenergized. The WD200 series are for horizontal or vertical mounting. Primary

More information

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Air Measuring Products. AMS Thermal Dispersion Pressure Differential Air Measuring Products AMS Thermal Dispersion Pressure Differential August 2014 1 Airflow Measuring Technologies Greenheck airflow measuring products are available with either differential pressure based

More information

HVAC Control & Balancing Dampers

HVAC Control & Balancing Dampers HVAC Control & Balancing Dampers Models VCD, MBD and RBD Selection Construction Performance H* W* 1June 2017 Design and Construction Features Bearing Shaft Extension Jamb Seal Commercial Control Dampers

More information

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 APPLICATION Ruskin model TED50XT is a low leak, thermally efficient damper with insulated extruded aluminum blades specially

More information

CFSD Series. Product Description

CFSD Series. Product Description COMBINATION FIRE AND SMOKE DAMPER 1-1/2 HR LEAKAGE RESISTANCE CLASS II 250 O F FILE NO: R22165 Product Description Combination Fire / Smoke dampers provide an automatic means of localizing areas of smoke

More information

Air Measuring Products AMD AMS IAQ

Air Measuring Products AMD AMS IAQ Air Measuring Products AMD AMS IAQ January 1 2012 Air Measuring Products Why is outside air measurement important? There are many significant benefits to monitoring outside air volumes. By measuring the

More information

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS 96 97 SD SERIES SD for Use in Dynamic Systems Types Galvanized Steel Construction as Standard.. Sleeve Type, Model: SD - 0-00. Circular Type, Model: SD - 50-00. Oval Type, Model: SD - 60-00

More information

HVAC Control & Balancing Dampers

HVAC Control & Balancing Dampers HVAC Control & Balancing Dampers Models VCD, MBD and RBD Selection Construction Performance H* W* August 1 2013 HVAC Control and Balancing Dampers Commercial Control Dampers are used in buildings to regulate

More information

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax)

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax) TO: Legacy Mechanical Inc 1455 So Platte River Dr Denver CO 80223 5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO 80111-4710 303-571-5377 303-629-7467 (fax) PROJECT: JCS - Columbine High School

More information

Fire, Smoke, and Combination Fire Smoke Dampers

Fire, Smoke, and Combination Fire Smoke Dampers Fire, Smoke, and Combination Fire Smoke Dampers Installation/Configuration Fire Dampers Smoke Dampers Agenda Combination Fire/Smoke Dampers Operational Test/Inspection Periodic Test/Maintenance Damper

More information

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR) UL CLASSIFIED DAMPERS COMBINED FIRE/SMOKE DAMPER - BMFSD SERIES STANDARD CONSTRUCTION Standards: Designed and tested in accordance with UL555 & UL555S. Meets NFPA 90A and SMACNA requirements for fire &

More information

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type ) ( Flange Type ) SPK 30-100 Standard Construction FRAME: 160mm x 30mm x 1.5mm (16 Ga.) galvanized steel formed channel for flange connection. BLADES: 250mm max. width, 1.5mm (16 Ga.) galvanized steel. FINISH:

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 461338 SMOKE DAMPERS SMD-XXX, SMD-XXXEF, SMD-XXXM, SMD-XXXV, SESMD-XXX, SSSMD-XXX, SMDR-XXX, SESMDR-XXX, and SSSMDR-XXX Series Leakage Rated Smoke Dampers Vertical and Horizontal Mount Installation,

More information

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FX (816) 765-8955 FSD36, FSD36LP COMINTION FIRE ND SMOKE DMPER 1 1 /2 HOUR UL555 RTED, UL555S LEKGE CLSS 2 PPLICTION Ruskin FSD36 Series low leakage

More information

SMOKE DAMPER - CLASS F MODEL BMSD

SMOKE DAMPER - CLASS F MODEL BMSD UL CLASSIFIED DAMPERS SMOKE DAMPER - BMSD SERIES STANDARD CONSTRUCTION Standards: Designed and tested in accordance with UL555S. Meets NFPA 90A and SMACNA requirements for fire & smoke dampers. Application:

More information

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type 1 SUBMITTAL DATA Series 1000 Air-Foil Control Damper SP Standard Profile 2" 50.8 mm In Duct or Flanged to Duct Install Types 4" 101.6 mm 6.4" 162.6 mm blades fully open 1" 25.4 mm Extended Rear Flange

More information

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FX (816) 765-8955 FSD60, FSD60LP COMINTION FIRE ND SMOKE DMPER 1 1 /2 HOUR UL555 RTED, UL555S LEKGE CLSS 1 PPLICTION Ruskin FSD60 Series ultra

More information

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation Life Safety Fire Combination Fire Smoke Smoke Ceiling Radiation June 2018 Table of Contents Introduction......................................... 3- Fire....................................... 5-19 Application...................................................

More information

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Positive Seal Damper Blades with Vinyl Gaskets 2.5 SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS BACKDRAFT DAMPERS BLADE OPTION: SR: 0.016-0.020 roll formed aluminum with vinyl gasket - used with fan motors under 1 HP SE: 0.05 extruded aluminum with vinyl gasket - used with fan motors over 1 HP Positive

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual Document 483514 SMOKE DAMPERS SMD-XXX and SMDR-XXX Series Leakage Rated Smoke Dampers Vertical and Horizontal Mount Please read and save these instructions

More information

MULTI-BLADE FIRE DAMPERS

MULTI-BLADE FIRE DAMPERS MODL D1201-DOW (1 1/2 HR.) OUT OF WALL DYNAMIC FIR DAMPR AIRFOIL BLAD DUCTD BOTH SIDS D1201-DOW is an "out of wall" (vertical mount) or "out of floor" (horizontal mount) high performance dynamic fire damper

More information

SD-1250 and SD-1600 Series Smoke Dampers

SD-1250 and SD-1600 Series Smoke Dampers SD-1250 and SD-1600 Series Smoke Dampers Product Bulletin Code No. LIT-1201592 Issued January 30, 2014 Supersedes October 14, 2013 Johnson Controls provides a leakage-rated damper for life safety smoke

More information

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING PUB. NO. 732-3 DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING The most widely used dampers in commercial HVAC applications Control Dampers - Extruded Aluminum

More information

BD-1600 Balancing/Zone Control Damper

BD-1600 Balancing/Zone Control Damper BD-1600 Balancing/Zone Control Damper Product Bulletin Code No. LIT-12012355 Issued September 2016 Refer to the QuickLIT website for the most up-to-date version of this document. The BD-1600 Balancing/Zone

More information

MULTI-BLADE FIRE DAMPERS

MULTI-BLADE FIRE DAMPERS MULTI-BLAD FIR DAMPRS MODLS 1201-MDG & 1201-MDS MULTI-BLAD MARIN FIR DAMPRS AIRFOIL BLAD LOW LAKAG Model Series 1201-MDG and 1201-MDS are Multi-Blade Low Leakage Fire Dampers for use in marine applications

More information

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

CONTROL DAMPERS. Models 1810 & Model Model Model 1370 CONTROL DAMPERS CONTROL DAMPERS MODELS 1810 & 1820 MANUAL ALANCING DAMPERS STEEL Models 1810 and 1820 have been engineering and designed for manual balancing applications in low to medium pressure and

More information

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7 CONTROL DAMPERS MODEL 1380 HIGH PERFORMANCE ACKDRAFT DAMPER EXTRUDED ALUMINUM HEAVY DUTY Model 1380 is a high performance extruded aluminum gravity operated backdraft damper for use in medium to heavy

More information

ARROW INDUSTRIAL PRODUCTS

ARROW INDUSTRIAL PRODUCTS IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products

More information

ID-141x 12-Gauge Hat Channel Industrial Damper

ID-141x 12-Gauge Hat Channel Industrial Damper ID-141x 12-Gauge Hat Channel Industrial Damper Product Bulletin Code No. LIT-12011355 Issued June 12, 2013 Supersedes March 13, 2012 Since 1905, Johnson Controls has developed and refined air control products

More information

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

HVAC Control Damper Models VCD and MBD. Selection Construction Performance HVAC Control Damper Models VCD and MBD Selection Construction Performance November 2006 HVAC Control and Manual Balancing Dampers Greenheck HVAC control dampers bring the same quality engineering and manufacturing

More information

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories. Insulated Control Dampers 2 Volume 1 - March 2010 6 Non-Insulated Control Dampers 8 Framing Accessories 9 Jack Shaft Steel Control Dampers Fire Dampers 10 11 Control Dampers and Fire Dampers 3900 Insulated

More information

Part # Installation,Operation and Maintenance Instructions

Part # Installation,Operation and Maintenance Instructions Part #461336 Installation,Operation and Maintenance Instructions for FSD-xxX, DFD-XXX, DFDTF-XXX CFSD-XXX, SEDFD-XXX, SEFSD-XXX, IMO-XXX, and SSFSD-XXX Series 1 1 2 and 3 Hour Fire & Combination Fire Smoke

More information

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES SECTION - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this

More information

RECEIVING AND HANDLING INSTALLATION SUPPLEMENTS WARRANTY SAFETY WARNING:

RECEIVING AND HANDLING INSTALLATION SUPPLEMENTS WARRANTY SAFETY WARNING: Part #461336 Installation,Operation and Maintenance Instructions for FSD-XXX, DFD-XXX,DFDTF-XXX CFSD-XXX,SEDFD-XXX, SEFSD-XXX, IMO-XXX, AND SSFSD-XXX SERIES 1 1 2 and 3 Hour Fire & Combination Fire Smoke

More information

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section SECTION 15910 DUCT ACCESSORIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division-1 Specification Sections,

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

Fire Dampers Catalogue

Fire Dampers Catalogue Fire s Catalogue DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) CRFD - Type A, B, CR & CO Rectangular, Round & Flat Oval UL 555 Classified 2013 For Use in Static & Dynamic Systems 3 Hour Rating Made in

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

SafidDampers SPK Description. Standard Construction SPK ( Flange Type ) ( Flange Type ) SPK 30-300 Description SPK 30 - Series The single and multi-leaf s with extruded aluminum airfoil blades are designed for quite, efficient and reliable air volume control in air conditioning

More information

AIR DUCT ACCESSORIES

AIR DUCT ACCESSORIES SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 GENERAL 1.1 SUMMARY A. Work included: 1. Sheet Metal Materials 2. Backdraft Dampers 3. Dampers 4. Concealed Damper Hardware 5. Access Doors 6. Duct Test Holes

More information

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers Control s Model FDCB (Opposed Blade) FDHB (Parallel Blade) Aluminum Low Leakage Control s Frame:.081 extruded aluminum Blades:.125 extruded aluminum Bearings: bronze oilite Linkage: *concealed in frame

More information

Introduction to Johnson Controls Dampers

Introduction to Johnson Controls Dampers Damper and Actuator Product Guide 268.1 Damper Engineering Section Product Bulletin Issue Date 1297 Introduction to Johnson Controls Dampers For over 100 years, Johnson Controls has been the industry leader

More information

Life Safety Dampers - International. Fire Combination Fire Smoke Smoke Ceiling Radiation

Life Safety Dampers - International. Fire Combination Fire Smoke Smoke Ceiling Radiation Life Safety - International Fire Combination Fire Smoke Smoke Ceiling Radiation June 2018 Fire Greenheck s employees are deeply committed to being easy to do business with anywhere in the world. As an

More information

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers AMCA MEMBER American Warming and Ventilating A Mestek Company Quality Air Control Dampers Over a century of dedication to quality products and customer satisfaction has enabled American Warming and Ventilating

More information

Blast Protection Damper

Blast Protection Damper Protection Damper plate shown as transparent height width 250mm wide 6.35mm thick blast plate bolted to damper frame 178mm 250mm standard depth 76mm standard flange Application The damper is designed for

More information

Series HCD Airfoil Control Damper

Series HCD Airfoil Control Damper Series HCD Airfoil Control Damper Model: HCD-1 The Holyoake HCD-1 is a precisely made volume and pressure control device with extremely low leakage when closed, (in the range of 0.003m 3 /s at 100 Pa).

More information

LLOYD INDUSTRIES INC.

LLOYD INDUSTRIES INC. 1-1/2 HOUR FIRE/SMOKE DAMPER FIRE/SMOKE DAMPER VERTICAL OR HORIZONTAL MOUNT 1-1/2HR RATING (Bi-Directional) (For use in 2hour or less rated partitions) Located in pin grooves. Minimum Size Single Section

More information

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400 SERIES 400 Series 900 Volume Control And Shut Off Dampers: Series 900 balancing and shut off dampers have been designed, engineered and tested, with smooth efficient operation as an important consideration.

More information

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan Centrifugal Cabinet s BDF Belt Drive Duct July 007 BDF Belt Drive Duct s Greenheck s Belt Drive Duct s, BDF, provide the industry s best performance and durability. BDF is carefully engineered for efficiency

More information

MODEL 151B FIRE DAMPER

MODEL 151B FIRE DAMPER ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Stock ID: IOM-151B January, 2003 2003 Miami Tech Inc., Inc. Miami, FL Miami Tech T Inc. MODEL 151B FIRE INSTALLATION INSTRUCTIONS The City of New York 909-89-SM California

More information

Dynamic & Static Rated Fire Dampers, Ceiling Radiation Dampers. UL Classified High Free Area Minimal Pressure Drop

Dynamic & Static Rated Fire Dampers, Ceiling Radiation Dampers. UL Classified High Free Area Minimal Pressure Drop Dynamic & Static Rated Fire Dampers, Ceiling Radiation Dampers UL Classified High Free Area Minimal Pressure Drop December 2005 Volume 21 Dynamic Fire Dampers & Static Rated Fire Dampers, Ceiling Radiation

More information