1 HP 40 HP. List Price Model Number H W D

Size: px
Start display at page:

Download "1 HP 40 HP. List Price Model Number H W D"

Transcription

1 Economical Solu ons for Basic Applica ons Siemens s Non Combina on NEMA R Enclosure PACKAGE VARIABLE TORQUE 240V: /4 HP to 60 HP 480V: 1 HP to 200 HP NON COMBINATION NEMA R ❶ 1 HP 200 HP Ra ngs in Stock ❷ Heavy Duty / Fully Gasketed / NEMA R Enclosure ❸ Easy to Use for Basic Applica ons Cooling (40 C) (50 HP 200 HP) ❺ Line Side Harmonic Filtering ❻ PID Loop Control Capable with Analog Input ❼ Heavy Duty Li ing Ears (50 HP 200 HP) ❽ Padlockable Door ❾ UL 508A Cer fied ❿ Two Year Warranty ⓫ Other Op ons Available² 1 HP 40 HP 50 HP 200 HP SIEMENS VT 2052N 001RP00 1Z $2,610 V N 1P5RP00 1Z $2,656 V N 002RP00 1Z $2,687 V N 00RP00 1Z $2,765 V N 005RP00 1Z $2,909 V N 7P5RP00 1Z $,068 V N 010RP00 1Z $,1 V N 015RP00 1Z $,628 V N 020RP00 1Z $,926 V N 025RP00 1Z $4,64 V N 00RP00 1Z $4,726 V N 040RP00 1Z $5,029 V N 050TP00 1Z $11,22 G N 060TP00 1Z $1,58 G N 075TP00 1Z $14,62 G N 100TP00 1Z $17,06 G N 125TP00 1Z $18,989 G N 150TP00 1Z $20,50 G N 200TP00 1Z $2,620 G120 ¹ HP ra ngs are for reference only. Starter size is dependent on the nameplate Full Load (FLA) ra ng of the motor. ² Please reference pages for available op ons, or contact us at for assistance. 78

2 Economical Solu ons for Basic Applica ons Siemens s Combina on Circuit Breaker Disconnect NEMA R Enclosure ❶ 1 HP 200 HP Ra ngs in Stock ❷ Heavy Duty / Fully Gasketed / NEMA R Enclosure ❸ Easy to Use for Basic Applica ons Cooling (40 C) (50 HP 200 HP) Through Door Disconnect (1 HP 40 HP); Flanged Disconnect (50 HP 200 HP) ⓬ Heavy Duty Li ing Ears (50 HP 200 HP) 1 HP 40 HP PACKAGE VARIABLE TORQUE 50 HP 200 HP 240V: /4 HP to 60 HP 480V: 1 HP to 200 HP CIRCUIT BREAKER NEMA R 2052B 001RP00 25J $,101 V B 1P5RP00 25J $,11 V B 002RP00 25J $,178 V B 00RP00 25J $,256 V B 005RP00 25J $,99 V B 7P5RP00 25J $,559 V B 010RP00 25J $,804 V B 015RP00 25J $4,119 V B 020RP00 25J $4,416 V B 025RP00 25J $5,149 V B 00RP00 25J $5,2 V B 040RP00 25J $5,569 V B 050TP00 25J $11,562 G B 060TP00 25J $1,841 G B 075TP00 25J $15,017 G B 100TP00 25J $17,259 G B 125TP00 25J $18,941 G B 150TP00 25J $20,77 G B 200TP00 25J $2,890 G120 ¹ HP ra ngs are for reference only. Starter size is dependent on the nameplate Full Load (FLA) ra ng of the motor. ² Please reference pages for available op ons, or contact us at for assistance. SIEMENS VT 79

3 Economical Solu ons for Basic Applica ons Siemens s Combina on Fused Disconnect NEMA R Enclosure ❶ 1 HP 200 HP Ra ngs in Stock ❷ Heavy Duty / Fully Gasketed / NEMA R Enclosure ❸ Easy to Use for Basic Applica ons Cooling (40 C) (50 HP 200 HP) Through Door Disconnect (1 HP 40 HP); Flanged Disconnect (50 HP 200 HP) ⓬ Heavy Duty Li ing Ears (50 HP 200 HP) 1 HP 40 HP PACKAGE VARIABLE TORQUE 50 HP 200 HP 240V: /4 HP to 60 HP 480V: 1 HP to 200 HP FUSED NEMA R SIEMENS VT 2052F 001RP00 25J $,66 V F 1P5RP00 25J $,95 V F 002RP00 25J $,442 V F 00RP00 25J $,520 V F 005RP00 25J $,66 V F 7P5RP00 25J $,98 V F 010RP00 25J $4,181 V F 015RP00 25J $4,475 V F 020RP00 25J $4,772 V F 025RP00 25J $5,252 V F 00RP00 25J $5,25 V F 040RP00 25J $5,727 V F 050TP00 25J $11,899 G F 060TP00 25J $14,697 G F 075TP00 25J $15,82 G F 100TP00 25J $18,026 G F 125TP00 25J $21,509 G F 150TP00 25J $2,02 G F 200TP00 25J $26,140 G120 ¹ HP ra ngs are for reference only. Starter size is dependent on the nameplate Full Load (FLA) ra ng of the motor. ² Please reference pages for available op ons, or contact us at for assistance. Motor Controls Catalog

4 Economical Solu ons for Basic Applica ons Siemens s Non Combina on NEMA R Enclosure PACKAGE CONSTANT TORQUE 240V: 1/2 HP to 60 HP 480V: 1 HP to 150 HP NON COMBINATION NEMA R ❶ 1 HP 150 HP Ra ngs in Stock ❷ Heavy Duty / Fully Gasketed / NEMA R Enclosure ❸ Easy to Use for Basic Applica ons Cooling (50 C) (40 HP 150 HP) ❺ Line Side Harmonic Filtering ❻ PID Loop Control Capable with Analog Input ❼ Heavy Duty Li ing Ears (40 HP 150 HP) ❽ Padlockable Door ❾ UL 508A Cer fied ❿ Two Year Warranty ⓫ Other Op ons Available² 1 HP 0 HP 40 HP 150 HP 2152N 001RP00 1Z $2,610 V N 1P5RP00 1Z $2,656 V N 002RP00 1Z $2,687 V N 00RP00 1Z $2,765 V N 005RTP00 1Z $2,909 V N 7P5RP00 1Z $,068 V N 010RP00 1Z $,1 V N 015RP00 1Z $,628 V N 020RP00 1Z $,926 V N 025RP00 1Z $4,726 V N 00RP00 1Z $5,029 V N 040TP00 1Z $11,22 G N 050TP00 1Z $1,58 G N 060TP00 1Z $14,62 G N 075TP00 1Z $16,869 G N 100TP00 1Z $18,989 G N 125TP00 1Z $20,50 G N 150TP00 1Z $22,017 G120 ¹ HP ra ngs are for reference only. Starter size is dependent on the nameplate Full Load (FLA) ra ng of the motor. ² Please reference pages for available op ons, or contact us at for assistance. SIEMENS CT 91

5 Economical Solu ons for Basic Applica ons Siemens s Combina on Circuit Breaker Disconnect NEMA R Enclosure ❶ 1 HP 150 HP Ra ngs in Stock ❷ Heavy Duty / Fully Gasketed / NEMA R Enclosure ❸ Easy to Use for Basic Applica ons Cooling (50 C) (40 HP 150 HP) Through Door Disconnect (1 HP 0 HP); Flanged Disconnect (40 HP 150 HP) ⓬ Heavy Duty Li ing Ears (40 HP 150 HP) 1 HP 0 HP PACKAGE CONSTANT TORQUE 40 HP 150 HP 240V: 1/2 HP to 60 HP 480V: 1 HP to 150 HP CIRCUIT BREAKER NEMA R SIEMENS CT 2152B 001RP00 25J $,101 V B 1P5RP00 25J $,11 V B 002RP00 25J $,178 V B 00RP00 25J $,256 V B 005RP00 25J $,400 V B 7P5RP00 25J $,559 V B 010RP00 25J $,804 V B 015RP00 25J $4,119 V B 020RP00 25J $4,416 V B 025RP00 25J $5,2 V B 00RP00 25J $5,569 V B 040TP00 25J $11,562 G B 050TP00 25J $1,778 G B 060TP00 25J $15,017 G B 075TP00 25J $17,172 G B 100TP00 25J $18,941 G B 125TP00 25J $20,455 G B 150TP00 25J $22,287 G120 ¹ HP ra ngs are for reference only. Starter size is dependent on the nameplate Full Load (FLA) ra ng of the motor. ² Please reference pages for available op ons, or contact us at for assistance. 92

6 Economical Solu ons for Basic Applica ons Siemens s Combina on Fused Disconnect NEMA R Enclosure PACKAGE CONSTANT TORQUE 240V: 1/2 HP to 60 HP 480V: 1 HP to 150 HP FUSED NEMA R ❶ 1 HP 150 HP Ra ngs in Stock ❷ Heavy Duty / Fully Gasketed / NEMA R Enclosure ❸ Easy to Use for Basic Applica ons Cooling (50 C) (40 HP 200 HP) Through Door Disconnect (1 HP 0 HP); Flanged Disconnect (40 HP 150 HP) ⓬ Heavy Duty Li ing Ears (40 HP 150 HP) 1 HP 0 HP 40 HP 150 HP 2152F 001RP00 25J $,66 V F 1P5RP00 25J $,95 V F 002RP00 25J $,442 V F 00RP00 25J $,520 V F 005RP00 25J $,66 V F 7P5RP00 25J $,98 V F 010RP00 25J $4,181 V F 015RP00 25J $4,475 V F 020RP00 25J $4,772 V F 025RP00 25J $5,25 V F 00RP00 25J $5,727 V F 040TP00 25J $11,840 G F 050TP00 25J $14,116 G F 060TP00 25J $15,80 G F 075TP00 25J $18,00 G F 100TP00 25J $19,708 G F 125TP00 25J $2,02 G F 150TP00 25J $24,57 G120 ¹ HP ra ngs are for reference only. Starter size is dependent on the nameplate Full Load (FLA) ra ng of the motor. ² Please reference pages for available op ons, or contact us at for assistance. SIEMENS CT 9

Motor Controls Made Easy 508A

Motor Controls Made Easy 508A Motor Controls Made Easy 508A Siemens Drive Package Partner Program MISSION STATEMENT To provide complete automa on solu ons for the United States and interna onal market with products and service that

More information

Motor Controls Made Easy 508A

Motor Controls Made Easy 508A Motor Controls Made Easy 508A Siemens Drive Package Partner Program MISSION STATEMENT To provide complete automa on solu ons for the United States and interna onal market with products and service that

More information

NEMA 4X. Motor Controls Made Easy. Wash Down Panel Packages 508A

NEMA 4X. Motor Controls Made Easy. Wash Down Panel Packages 508A NEMA 4X Motor Controls Made Easy 508A Wash Down Panel Packages MISSION STATEMENT To provide complete automa on solu ons for the United States and interna onal market with products and service that meet

More information

GPH2 Combination Soft Starters

GPH2 Combination Soft Starters Combination Soft Starters The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general purpose AC motor soft starter package. It is designed for simple and quick installation and start-up, requiring

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

High Temp. Mold Series HIGH TEMPERATURE GAS SPRINGS

High Temp. Mold Series HIGH TEMPERATURE GAS SPRINGS High Temp. Mold Series HIGH TEMPERATURE GAS SPRINGS IDEAL L FOR THE HIGHER WORKING TEMPERATURES TYPICAL T IN PLASTIC MOLDS T2M & T3M Series GENUINELY HYSON Since 1964 Hyson has been dedicated to providing

More information

Air Conditioning Disconnects Molded Case Switch

Air Conditioning Disconnects Molded Case Switch Air Conditioning Disconnects Molded Case Switch Catalog 3150CT0401R08/09 2009 Class 3150 QO200TR QO200TRNM CONTENTS Description............................................. Page..........................................

More information

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers Product Guide QR Circuit Breaker usa.siemens.com/circuitbreakers Advantages to reduce your cost and improve installation flexibility. 250A, 240V AC breakers up to 100kAIC. Updated design includes pushtotrip

More information

Sensorless Vector Drives

Sensorless Vector Drives STANDARD PRODUCTS Sensorless Vector Drives SG SERIES STANDARD DUTY / HEAVY DUTY RATINGS Variable Torque: 7.5 to 700HP @ 460V 7.5 to 40HP @ 2V Standard Duty: 7.5 to 600HP @ 460V 7.5 to 40HP @ 2V Heavy Duty:

More information

For many applications

For many applications Series 40 Amp Rugged and dependable 40 amp switches for industrial applications Sprecher + Schuh s rugged rotary cam switches are available for most control and load applications up to 40 amps. A well

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

Short-Circuit Current Ratings

Short-Circuit Current Ratings UL 508 Type E Combination Motor Controller, TeSys GV Combination Meeting UL 508 Type E, UL File E164871 Table 2: TeSys GV2P Horsepower and SCCR Ratings In combination with line spacer GV2GH7 (stand-alone

More information

GEAR PUMP SYSTEMS PROCESS & CHEMICAL FEED EQUIPMENT

GEAR PUMP SYSTEMS PROCESS & CHEMICAL FEED EQUIPMENT PROCESS & CHEMICAL FEED EQUIPMENT Oil & Gas Power Genera on Chemical Processing Mining Pulp and Paper Water Resources Pharmaceu cal GEAR PUMP SYSTEMS USA +1.251.662.1250 phone +1.251.662.8250 fax Gear

More information

Aquacultural Catalog. Aquacultural Catalog 508A

Aquacultural Catalog. Aquacultural Catalog 508A Aquacultural Catalog Aquacultural Catalog 508A MISSION STATEMENT To provide complete automation solutions for the United States and international market with products and service that meet or exceed customer

More information

EPS-ECONOMY PUMP STARTER

EPS-ECONOMY PUMP STARTER EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides

More information

SP600 AC Drives MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3)

SP600 AC Drives MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3) MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3) SP Models: (4) Analog Input #1 (0-10 VDC or 4-20 ma) Analog Output (0-10 VDC) Refer to the Standard Motors and Drives Catalog for Standard features

More information

Flange Mounted Disconnect Switch. Installation Instructions. Item: I.L. No A00 1 / 12 VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F

Flange Mounted Disconnect Switch. Installation Instructions. Item: I.L. No A00 1 / 12 VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F Flange Mounted Disconnect Switch Item: VBFS321F VBFS361F VBFS322F VBFS362F VBFS363F VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F Installation Instructions Hazardous Voltage. 1 / 12 I.L. No. 500524A00

More information

Overload Relay Heater Tables

Overload Relay Heater Tables Overload Relay Tables of Elements for Overload Relays General Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average

More information

SIGNAL WORDS QUALIFIED PERSON

SIGNAL WORDS QUALIFIED PERSON SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or

More information

VS1PFB 230V, 50/60 Hz, 3-Phase

VS1PFB 230V, 50/60 Hz, 3-Phase Farm Duty Unit Handling Brake 200 & 575 Volt Pump and Fan Bypass AC Drive 7.5 thru 40 Hp 7.5 thru 125 Hp & Controls 230 VAC 460 VAC 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications: Pump and Fan AC Drive

More information

T2 Mini Series MINI NITROGEN GAS SPRINGS IDEAL FOR: REPLACING COIL SPRINGS STOCK LIFTING & EJECTION

T2 Mini Series MINI NITROGEN GAS SPRINGS IDEAL FOR: REPLACING COIL SPRINGS STOCK LIFTING & EJECTION T2 Mini Series MINI NITROGEN GAS SPRINGS IDEAL FOR: REPLACING COIL SPRINGS STOCK LIFTING & EJECTION T2 Series Mini Nitrogen Gas Springs Table of Contents Page Introduc on, Ordering Informa on 1 FOR REPLACING

More information

NPL Series LOW HEIGHT GAS SPRINGS PLL I CATIONS WHERE IGHT IS RESTRICTED

NPL Series LOW HEIGHT GAS SPRINGS PLL I CATIONS WHERE IGHT IS RESTRICTED NPL Series LOW HEIGHT GAS SPRINGS IDEAL EAL FFOR O R STAMPING APPLICATIONS PLL I CATIONS WHERE HEIGHT IGHT IS RESTRICTED NPL Series 2 1-800-876-4976 440-526-5900 www.hysonproducts.com Hyson Products 2014

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Mechanically Operated and Solid-state

More information

Applica on Note 109. Switch for Smart Locks. Relevant Products: Introduc on. Smart Lock System Diagram. Features and Benefits

Applica on Note 109. Switch for Smart Locks. Relevant Products: Introduc on. Smart Lock System Diagram. Features and Benefits Relevant Products: CT510 Series Digital Switch Introduc on New keyless, smart locks are emerging and replacing the tradi onal key deadbolt locks. With this new technology, the key is no longer used and

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,

More information

FREE-STANDING ENCLOSURE ACCESSORIES FREE-STANDING ENCLOSURE ACCESSORIES. Swing-Out Panels. Panels (Full & Half Length) For Single-Door Enclosures

FREE-STANDING ENCLOSURE ACCESSORIES FREE-STANDING ENCLOSURE ACCESSORIES. Swing-Out Panels. Panels (Full & Half Length) For Single-Door Enclosures 118 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST 11 ENCLOSURE Panels (Full & Half Length) For Single-Door Enclosures Panels for single-door enclosures can

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide Retain for future use. 30072-450-47A July 2002 Raleigh, NC, USA HAZARDOUS VOLTAGE Read and understand

More information

Product Guide. enclosed NEMA STARTERS

Product Guide. enclosed NEMA STARTERS Product Guide enclosed NEMA STARTERS The Right Choice for Applications that Demand the Best. Siemens NEMA Combination and Non- Combination Starters for Industrial and Construction Applications Rugged,

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD Safety Precautions Read this manual thoroughly before proceeding with installation, connections (wiring), or maintenance and inspection. Ensure you

More information

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Product guide. Enclosed NEMA starters. usa.siemens.com/controls Product guide Enclosed NEMA starters usa.siemens.com/controls The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction

More information

ACH550 VARIABLE FREQUENCY DRIVES FOR HVAC APPLICATIONS

ACH550 VARIABLE FREQUENCY DRIVES FOR HVAC APPLICATIONS ACH550 VARIABLE FREQUENCY DRIVES FOR HVAC APPLICATIONS (Disconnect and Bypass Packages are available on Pages 56 and 57) Two Year Warranty* *When Gerrie commissions the drive Features: UL/cUL/CSA Approved

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

GE Push Buttons. CRW4P Heavy-Duty Push Button Contact Blocks

GE Push Buttons. CRW4P Heavy-Duty Push Button Contact Blocks CRW4P Heavy-Duty Push Button Contact Blocks CH104P Heavy-Duty Push Button Contact Blocks CR104P Heavy-Duty Push Buttons ~\ GE Push Buttons CRW4P Heavy-Duty Push Buttons 600 Volts Maximum AC/DC 10 Amperes

More information

EPS-ECONOMY PUMP STARTER

EPS-ECONOMY PUMP STARTER EPS-ECONOMY PUMP STARTER 1 & 3 Phase, 50/60Z, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides a simple and dependable starting option with a wide electronic overload

More information

Standard Product. Type 4 Free-Stand Enclosures and Accessories

Standard Product. Type 4 Free-Stand Enclosures and Accessories 763.422.2600 Spec-00294 F763.422.2211 Free-Stand Enclosures Type 4 Free-Stand Enclosures and Accessories Free-Stand Enclosures Type 4 Free-Stand Enclosures and Accessories Free-Stand, Type 4 INDUSTRY STANDARDS

More information

Standard Materials Bodies and covers: copper-free aluminum.

Standard Materials Bodies and covers: copper-free aluminum. -26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and

More information

Product guide. Enclosed NEMA starters. Answers for industry.

Product guide. Enclosed NEMA starters. Answers for industry. Product guide Enclosed NEMA starters Answers for industry. The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction applications

More information

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches I.L. 29C284B File 29-000 Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON

More information

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum . Selection Pump Panel Design N = Freedom 2 = A200 V = Vacuum Class 54 = Type 3R pump panel fusible disconnect 55 = Type 3R pump panel circuit breaker disconnect 4 = Part winding with motor circuit 5 =

More information

Heat Tracing Sales Mt. Airy, Maryland Controls

Heat Tracing Sales Mt. Airy, Maryland Controls Heat Tracing Line Sensing Control Panels Solid State Relay Output Rated 30 Amps or Two-Pole Contactor Control Output Universal Inputs NEMA 4/4X Enclosure Ground Fault Alarm/Trip Monitor or GFI Circuit

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

DS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1

DS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1 New Information Supersedes Data 33-790-1H, dated October 1996 DS/DSII Low Voltage Switchgear Page 1 DS Switchgear Assembly DSII Switchgear Assembly Contents Pages DS Switchgear (Front View) 2 DSII Switchgear

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit

More information

Options 230V Description Qty 3M 8 U S 15 standard unit 2 3M 8 U S 25 standard unit 2 3M 8 U S M 8 U S 60 standard unit

Options 230V Description Qty 3M 8 U S 15 standard unit 2 3M 8 U S 25 standard unit 2 3M 8 U S M 8 U S 60 standard unit DC Brakes Stock List as of Sept, 06 RVS DX Standard Duty Soft Starter with built in bypass 400V Models (for 08 400V) RVSDX 44 400 5 RVSDX 7 400 5 RVSDX 05 400 5 RVSDX 45 400 5 RVSDX 70 400 5 Options HP@08

More information

Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

Motors  GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2 GRUNDFOS GROUNDWATER SERVICE MANUAL Motors 4-6-8-10" CONTENTS Grundfos Motor Specifications... Page 2 Electrical Requirements... Page 8 -Transformer Capacity Maximum Motor Cable Length... Page 10 Full

More information

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA Data Bulletin Raleigh, NC, USA ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION The ALTIVAR FLEX58 chassis drive controller offers OEMs, panel builders, integrators, and users a unique

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

EN4DSC Disconnect Enclosures - NEMA 4 ABB Controls, Allen Bradley, Cutler Hammer, General Electric, Siemens I-T-E Max-Flex, Square D

EN4DSC Disconnect Enclosures - NEMA 4 ABB Controls, Allen Bradley, Cutler Hammer, General Electric, Siemens I-T-E Max-Flex, Square D EN4DSC Disconnect Enclosures - NEMA 4 Application Designed to house the following safety disconnect equipment: ABB Controls flange mounted variable depth operating mechanisms for disconnect switches and

More information

Replacement Parts List FI 4009 & FI 4009C. SUPERSEDES: April 28, 2016 EFFECTIVE: October 18, 2016

Replacement Parts List FI 4009 & FI 4009C. SUPERSEDES: April 28, 2016 EFFECTIVE: October 18, 2016 A Taco Family Company Replacement Parts List FI 4009 & FI 4009C 304-403 SUPERSEDES: April 28, 2016 EFFECTIVE: October 18, 2016 WHEN SELECTING AND ORDERING PARTS, ALWAYS REFER TO SERIAL ON NAMEPLATE 00

More information

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP Phoenix DX Sensorless AC Vector Drive 3 HP to 3500 HP Standard Features: * PRECISE CONTROL OF MOTOR SPEED AND TORQUE * BI-DIRECTIONAL FLYCATCHER (CATCH SPINNING MOTOR) * EASY TO USE, SIMPLE SETUP * POWER

More information

HVAC-R Drive Products

HVAC-R Drive Products Motors Automation Energy Transmission & Distribution Coatings HVAC-R Drive Products Designed Especially for HVAC Systems US.HVAC-R Drive.Products.01/2017 www.weg.net/us WEG HVAC-R Products WEG, a leading

More information

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 H100R3C 3P 100A 600V F-Frame MC Protector Eaton Corp Catalog Number H100R3C Manufacturer Eaton Corp Description Motor Circuit

More information

ALTIVAR FLEX58 Chassis Drive Controller Product Selection

ALTIVAR FLEX58 Chassis Drive Controller Product Selection ALTIVAR FLEX58 Chassis Drive Controller Product Selection Class 8806 CONTENTS Description Page General Information and Selection....................................... 2 Specifications and Ratings...........................................

More information

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum .1 Catalog Number Selection Pump Panel Design N = Freedom 2 = A200 V = Vacuum Class 54 = Type 3R pump panel fusible disconnect 55 = Type 3R pump panel circuit breaker disconnect 4 = Part winding with motor

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch . Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A

More information

Features and Benefits. Control Features

Features and Benefits. Control Features Features and Benefits AC induction motors have become increasingly dominant in industrial facilities worldwide. Manufacturers faced with increasing pressure to control costs have recognized that motor

More information

Chapter 1: Getting Started User Manual Overview...1 2

Chapter 1: Getting Started User Manual Overview...1 2 Getting Started Chapter 1 Table of Contents Chapter 1: Getting Started User Manual Overview.........................................1 2 Overview of this Publication.........................................

More information

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications The Reliance Electric LiquiFlo AC drive combines high-performance variable speed drive technology with a patented liquid-cooling

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

UL/CSA Non-fused Disconnect Switches

UL/CSA Non-fused Disconnect Switches Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

Three-Phase Ventilated

Three-Phase Ventilated Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

Product Guide. NEMA pump controls.

Product Guide. NEMA pump controls. Product Guide NEMA pump controls www.usa.siemens.com/controls Class 87 full voltage pump controller with fusible disconnect switch and standard features Class 87 NEMA full starter pump control panels Product

More information

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES CIRCUIT BREAKERS Explosionproof Circuit Breaker Enclosures BREAKERS Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 800 amperes Also available as non-automatic

More information

Explosion Proof Motors

Explosion Proof Motors SINGLE-PHASE Foot Mount...A-110 C-Face Foot Mount...A-110 THREE-PHASE Foot Mount...A-112 C-Face Foot Mount...A-116 C-Face Footless...A-117 JP Foot Mount...A-117 ATEX Foot Mount...A-120 A-108 Fractional

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Dual ground lug - one lug for earth ground, one lug for utility ground.

Dual ground lug - one lug for earth ground, one lug for utility ground. The Type 3R Package is specifically designed for Yaskawa Variable Frequency Drives. The Type 3R outdoor duty package is not just a "NEMA 3R" self-declared rating. Yaskawa went beyond its own stringent

More information

T4 Series HEAVY DUTY GAS SPRINGS IDEAL FOR STAMPING ULTRA HIGH STRENGTH STEELS

T4 Series HEAVY DUTY GAS SPRINGS IDEAL FOR STAMPING ULTRA HIGH STRENGTH STEELS T4 Series HEAVY DUTY GAS SPRINGS IDEAL FOR STAMPING ULTRA HIGH STRENGTH STEELS T4 Series 2 T4 Series IDEAL FOR STAMPING ULTRA-HIGH STRENGTH STEELS Table of Contents Page PED - Pressure Equipment Direc!ve...

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

PowerFlex 700 User Manual Update

PowerFlex 700 User Manual Update DANGER REMOTE SOURCE(S) OF POWER. DISCONNECT ALL SOURCES OF POWER BEFORE OPENING THE DOOR. ENERGY STORAGE CAPACITORS. VERIFY LOW VOLTAGE DISCHARGE BEFORE SERVICING. SEE INSTRUCTION MANUAL. Document Update

More information

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x. Types MS116, MS132, MS5x, MS9x are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/OFF control, and protection against short circuit,

More information

Softstarters. Softstarters Power electronic brakes Type PEB

Softstarters. Softstarters Power electronic brakes Type PEB Softstarters Power electronic brakes Softstarters Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB)

More information

Installation Instructions

Installation Instructions Installation Instructions Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Operating Mechanisms For use with Circuit Breakers 140G-G, 140MG-G, 140G-H, 140MG-H, 140G-I, 140MG-I, 140G-J, 140MG-J,

More information

ELECTRICAL ENCLOSURES AND MODULAR CABINETS EXM MANUFACTURING LTD. Since 1975

ELECTRICAL ENCLOSURES AND MODULAR CABINETS EXM MANUFACTURING LTD. Since 1975 www.exmweb.com ELECTRICAL ENCLOSURES AND MODULAR CABINETS 19 EXM MANUFACTURING LTD. Since 1975 NEMA 12-13 SAFETY DISCONNECT 9500 UxD Right flange mounted disconnect multi-door enclosure The 9500 UxD oil

More information

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800

More information

Industrial and Commercial Duty IEC Motors

Industrial and Commercial Duty IEC Motors Industrial and Commercial Duty IEC Motors A Regal Brand Five product families delivering a world of opportunity LEESON Passport Series IEC Motors. There s a world of opportunity right here at home. The

More information

Ventilated Distribution Transformers

Ventilated Distribution Transformers Ventilated Distribution Transformers The Energy Policy Act of 2005 (H.R. 6) requires Distribution Transformers manufactured after January 1, 2007 to meet specifi c energy effi ciency requirements. EPAct

More information

Specialty Service Entrance Switchboards. Selection and Application Guide

Specialty Service Entrance Switchboards. Selection and Application Guide Specialty Service Entrance Switchboards Selection and Application Guide Power! As the heart of every business complex it has to be reliable. As part of your business, it has to be economical too.you get

More information

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A Conformity to standards (1) Changeover switches svr-ul_14_b_1_cat > EC 6947-3 > UL98, Guide WHTY, file 1138 > UL18, Guide WPYV, file 31792 > CSA 22.2#4, Class 4651-2 (1) Product reference on request. svr_136_a_2_cat

More information

P844L3MS For Models: NL844L3.1MS1 and NL844L3.1MS2 PARTS CATALOG. Marine Generators Marine Diesel Engines Land-Based Generators

P844L3MS For Models: NL844L3.1MS1 and NL844L3.1MS2 PARTS CATALOG. Marine Generators Marine Diesel Engines Land-Based Generators P844L3MS For Models: NL844L3.1MS1 and NL844L3.1MS2 PARTS CATALOG Marine Generators Marine Diesel Engines Land-Based Generators CALIFORNIA Proposition 65 Warning: Diesel engine exhaust and some of its constituents

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

ATLAS FOOT OPERATED SWITCH

ATLAS FOOT OPERATED SWITCH ATLAS FOOT OPERATED SWITCH 7.17 mm (8.55 IN) 108.97 mm (4.29 IN) 85.60 mm (3.37 IN) 103.12 mm (4.06 IN) 184.91 mm (7.28 IN) MOUNTING HOLES (3) Ø 7.94 mm (Ø.312 IN) 88.90 mm (3.50 IN) 40.64 mm (1.60 IN)

More information

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

1. Division 26 Section Elevator Shunt-Trip Fused Disconnect Switches. SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,

More information

CANADIAN BROCHURE Enclosed Circuit Breakers Tmax Range

CANADIAN BROCHURE Enclosed Circuit Breakers Tmax Range CANADIAN BROCHURE 2017 Tmax Range 5 ENCLOSED CIRCUIT BREAKERS - CANADIAN BROCHURE Reliable solution ABB solution for enclosed circuit breaker ABB s enclosed circuit breakers offer all the advantages and

More information

GHG43 Series Control Stations

GHG43 Series Control Stations GHG43 Series Control Stations Nonmetallic or 316L Stainless Steel UL/cUL listed Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zones 1 and 2, (A) Ex de IIB + H2 T6 Cl. II, Div. 1, Groups E, F, G (cul) PTB ATEX

More information

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters Motors Automation Energy Transmission & Distribution Coatings GPH2 Combination Soft Starters GPH2 Combination Soft Starter 5to 350 HP The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

Power Break II Switchboard

Power Break II Switchboard Power Break II Switchboard Now available with PowerBreak II Circuit Breakers through 4000A GE s Power Break II Switchboard is now available with the new Power Break II Insulated Case Circuit Breaker (800A

More information

Operator System Enclosures

Operator System Enclosures 27 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST Saginaw Control & Engineering s Type 12 Operator Systems are designed to house a wide variety of equipment; panel mount, rack mount, desktop PC s, monitors,

More information

Type 4 Panel Enclosures

Type 4 Panel Enclosures Type 4 Free-Standing ata Sheet Finish Wash and phosphate undercoat ANSI 61 gray polyester powder finish Accessories Full and half panels Side and swing panels Channel mounting hardware Equipment rack mounts

More information

Motors Automation Energy Transmission & Distribution Coatings EDP11. Enclosed Drive Panel USA EDP11

Motors Automation Energy Transmission & Distribution Coatings EDP11. Enclosed Drive Panel USA EDP11 Motors Automation Energy Transmission & istribution Coatings EP11 Enclosed rive Panel USA EP11 EP11 Enclosed rive Panel The Enclosed rive Panel is an industrial general purpose AC motor control and protection

More information

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS DIVISION 26 ELECTRICAL SECTION 26 28 19 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install circuit breakers in switchboards, distribution panelboards, and separate enclosures for overcurrent protection

More information

Low Voltage Products. Catalog. Flange Handle Operated Disconnect Switches. Non Fusible 30A A Fusible 30A - 800A

Low Voltage Products. Catalog. Flange Handle Operated Disconnect Switches. Non Fusible 30A A Fusible 30A - 800A Low Voltage Products Flange Handle Operated Switches Non Fusible 0A - 0A Fusible 0A - 800A Flange Handle Operated Switches Non Fusible 0A - 0A Fusible 0A - 800A 7 Page Shaft operated Cable operated Amp.

More information

Fincor Series 2230 MKII/2240

Fincor Series 2230 MKII/2240 Fincor Series 2230 MKII/ Fincor Series 2200 regenerative drives are ideal for your more demanding applications. They feature flexibility with ratings up to 5 horsepower. The Series 2230 MKII offers new

More information