B&R Enclosures HAZARDOUS AREAS CATALOGUE
|
|
- June Horn
- 5 years ago
- Views:
Transcription
1 B&R Enclosures HAZARDOUS AREAS CATALOGUE
2
3 Table of Contents INTRODUCTION B&R History Capabilities BReakthrough Solutions BRight Ideas PRODUCT SELECTION GUIDE Lighting Enclosures Plugs & Sockets Weatherproof Lighting & Enclosures TECHNICAL INFORMATION EX D ENCLOSURES Aluminium Ex d Enclosures ENCLOSURES Terminal Boxes Control Boxes Non-Metallic Enclosures LIGHTING LED Lighting Well Glass Lighting Floodlighting Caution Lighting Fluorescent Lighting Fluorescent & LED Lighting PLUG & SOCKET OUTLETS Plug & Socket Outlets WEATHERPROOF Floodlighting Non-Metallic Control Boxes Disclaimer This catalogue has been prepared specifically for customers of the publisher and as a general reference only. B&R Enclosures Pty Ltd engages in a policy of continuous development and improvement of its products and reserves the right to alter, add and/or delete specifications of any products or equipment without notice and without incurring liability. The publisher and any party associated with the production of this catalogue do not accept any responsibility or liability whatsoever (to the extent permitted by law) for any inaccuracy, error, misinformation or misleading statements, whether negligently caused or otherwise, contained in this publication. This publication is protected by copyright and may not be reproduced or copied (using any method of reproduction or copying), sold, transmitted, circulated or otherwise forwarded to third parties, in whole or part, without prior written consent of the author. All registered trademarks and product names appearing herein are the property of the respective owners.
4
5 Born and ed Australian A little bit about B&R Enclosures Since 1955, B&R has built a reputation for excellence in the design and manufacture of enclosures. Everything we have learned in that time, we ve poured into our products and relationships. As a 100% Australian, family-owned business, B&R champions the virtues of quality, service and value. Combined with our unrivalled industry and application knowledge, we are in a unique position to meet the needs of our clients. The company encompasses four divisions: Industrial, Data ICT, Hazardous Areas and Residential Commercial. Each division has focuses on the unique needs of different market segments. Together, these divisions share the strengths, resources and experience of the founding company to provide attentive customer service, innovative design and superior quality products at a competitive price. Quality is assured with B&R s certification to ISO 9001:2008. B&R is also accredited by the Australian Stainless Steel Association as a superior producer of stainless steel products, working to industry best practice. Our occupational health and safety management system is certified to AS/NZS 4801:2001. At B&R, we are justifiably proud of our products, and we strive to ensure that you have what you need, when you need them. We have a network of offices and distributors throughout Australia and internationally. Wherever you are, you will be able to buy B&R products nearby. B&R Enclosures was founded by Dick Bridges in 1955, specialising in sheet metal fabrication, including electrical enclosures for domestic metering applications. With little capital but great enthusiasm for operating his own business and a determination to succeed, Dick commenced operations in his backyard in Adelaide, South Australia. It was this family determination that has sustained B&R s growth into manufacturing plants in Brisbane, Adelaide and Sydney, 10 locations nationally and an international network of distributors, allowing them to increase the range, availability, quality and service to their customers. Under the direction of the founder s son, Ken and daughter, Chris, B&R Enclosures has grown to be the largest manufacturer of domestic, commercial and industrial enclosures in Australia.
6 Length and eadth With more than 300 employees in different locations, we are ready and able to rise to the biggest challenge. At B&R, we understand that technology and our people play an important role in making sure our products are of the highest quality. From material through to design and manufacturing, B&R do not compromise on quality. Our final product is not only functional but durable. Our capabilities include: 3D Solidworks modelling Automated laser cutter, robotic punching and bending machines Robotic foamed in place gasket application machinery Automated powdercoating lines with multi-stage pre-treatment process Value add services Warehousing and distribution In-house testing including IP protection rating, salt spray, structural, climate and electrical conformity
7
8
9 eakthrough solutions Our people are the best in the business. Experienced professionals with a passion for problem solving and a flair for innovation. At B&R, we not only manufacture and supply a range of enclosure solutions, but we can customise the design to be 100% fit-for-purpose and ready for installation. B&R Enclosures offer a wide range of services to customise standard product, ensuring that an enclosure is delivered ready for installation. We understand that time is a major consideration on any project and work with our customers to provide products on time and on budget. We have established two value add divisions located within our manufacturing facilities at Heathwood, Brisbane and Riverwood, Sydney. Our services include: Door cutouts Cable entries Terminals and controls fitted Viewing windows Customised wiring Vent kits / sunshields fitted or punched Assemble to order / fitting of accessories What this means for our customers: Customised product to suit the project Shorter lead times Available for small or large quantities One point of contact Standard product straight off the floor brenclosures.com.au
10 ight ideas With over 100 years combined industry experience, B&R Enclosures have built a reputation as leaders in the hazardous area market. Specialising in the supply of electrical equipment for hazardous areas, B&R Ex Systems utilises the manufacturing and distribution network of B&R Enclosures and a highly experienced team to deliver products of the highest standard. The company is dedicated to providing superior quality products, designed to meet the stringent requirements of the internationally recognised IEC Ex Certification Scheme. B&R Ex Systems accreditation to ISO 9001 for the design, manufacture and distribution of electrical equipment for hazardous areas. B&R Ex Systems offer a large range of enclosures, lighting, controls and cable glands, as well as IEC Ex certified value add services including custom control fit outs. The dedicated B&R Ex Systems team has over 100 years combined industry experience in the hazardous area market. The company's philosophy of quality is applied from design through to delivery, so you can be certain your hazardous area projects are safe and reliable. brenclosures.com.au
11
12 PRODUCT SELECTION GUIDE LIGHTING Product Description Protection Method Zones Page No. LED Exit Light Ex d 1 & LED Lowbay Light Ex d 1 & 2, 21 & LED Linear Light Ex d 1 & 2, 21 & LED Lowbay Light Ex d, Ex t 1 & 2, 21 & LED Lowbay Light Ex d e 1 & 2, 21 & LED Well Glass Ex d, Ex t 1 & 2, 21 & Well Glass Light 400W Ex d 1 & Well Glass Light Ex de 1 & W 400W Floodlight Ex de 1 & Well Glass Floodlight Ex nr, Ex t 1 & 2, 21 & W 400W Floodlight Ex nr, Ex t 1 & 2, 21 & Tank Inspection Vessel Light Ex d 1 & W Halogen Floodlights Ex n R Audio & Visual Caution Light Ex d 1 & 2 70 Visual Caution Light Ex d, Ex t 1 & 2, 21 & Local Visual Caution Light Ex de, Ex tb 1 & 2, 21 & Hazardous Areas
13 PRODUCT SELECTION GUIDE LIGHTING LIGHTING Product Description Protection Method Zones Page No. Local Visual Caution Light Ex de, Ex tb 1 & 2, 21 & Annular Compact Fluorescent Ex d 1 & Aluminium Fluorescent Ex d 1 & Stainless Steel Fluorescent Ex d emb, Ex d 1 & Non-Metallic Fluorescent Emergency & Non-Emergency Ex deq, Ex td 1 & 2, 21 & Non-Metallic Fluorescent Emergency & Non-Emergency Ex deqmb, Ex td 1 & 2, 21 & Aluminium Fluorescent & LED Ex d, Ex t 1 & 2, 21 & Non-Metallic Fluorescent & LED Emergency & Non-Emergency Ex na, Ex d na, Ex d mb, Ex t, Ex mb 2, 21 & Non-Metallic Fluorescent & LED Ex na, Ex t 2, 21 & Weatherproof Lighting WF1, IP brenclosures.com.au Hazardous Areas 11
14 PRODUCT SELECTION GUIDE ENCLOSURES, PLUG & SOCKET OUTLETS ENCLOSURES AND PLUG & SOCKET OUTLETS Product Description Protection Method Zones Page No. Ex d Enclosures Ex db, Ex tb, Ex d, Ex t 1 & 2, 21 & Sloping Roof Terminal Box Ex e, Ex na, Ex de, Ex td, DIP, Ex t 1 & 2, 21 & Flat Roof Terminal Box Ex e, Ex na, Ex de, Ex td, DIP, Ex t 1 & 2, 21 & Flat Roof Terminal Box Ex e, Ex na, Ex de, Ex td, DIP, Ex t 1 & 2, 21 & Stainless Steel Terminal Box Ex e, Ex na, Ex de, Ex td, DIP, Ex t 1 & 2, 21 & Sloping Roof Custom Built Control Box Ex e, Ex na, Ex de, Ex td, DIP, Ex t 1 & 2, 21 & Flat Roof Custom Built Control Box Ex e, Ex na, Ex de, Ex td, DIP, Ex t 1 & 2, 21 & Flat Roof Custom Built Control Box Ex e, Ex na, Ex de, Ex td, DIP, Ex t 1 & 2, 21 & Stainless Steel Control Station Ex e, Ex na, Ex de, Ex td, DIP, Ex t 1 & 2, 21 & Non-Metallic Control Station Ex ed, Ex td 1 & 2, 21 & Non-Metallic Terminal Box Ex e, Ex td 1 & 2, 21 & Non-Metallic Terminal Box Ex e, Ex td 1 & 2, 21 & Plug & Socket Outlets Ex de, Ex td 1 & 2, 21 & Non-Metallic Control Box Weatherproof Control Box Hazardous Areas
15 TECHNICAL INFORMATION What is a hazardous area? A hazardous area is an area where flammable liquids, vapours, gases or combustible dusts are likely to occur in sufficient quantities to cause fire or explosion. Industries such as metalliferous mining, oil and gas infrastructure, automotive refuelling stations, chemical processing plants, printing industries and cement works often have hazardous applications. There are three basic conditions that must be satisfied to create a fire or explosion. 1. Flammable or combustible material such as flammable Liquid, vapour or combustible dust must be present in sufficient quantity and concentration. 2. Oxygen 3. Ignition source Flammable or combustible material Hazardous area electrical equipment works by suppressing or separating one or more of these three components to avoid a fire or explosion. Ignition Sources The following ignition sources have the potential to cause an explosion in the right circumstances: Electric arcs and spark Flames Hot surfaces Electrostatic sparks Thermite sparks Mechanical friction Oxygen Mechanical sparks produced by grinding Smouldering deposits Compression ignition Electromagnetic radiation Chemical reactions Ultrasonics Ignition source IEC Standards & Certifications IEC Ex is an internationally recognised scheme for the certification of hazardous area electrical equipment. The IEC Ex System is designed to facilitate international trade in equipment and services for use in hazardous areas, while maintaining the required level of safety. 1 Required Information There are 4 important pieces of information required when selecting equipment for hazardous areas. Zone Classification Gas Group Temperature or T Rating IP Rating Zone Classifications Equipment that is used in hazardous areas is classified into zones, depending on the potential of an explosion under normal operating conditions. The table below is a guide to zone classification of hazardous areas. B&R Ex Systems does not classify areas for customers, it is the responisbility of the installer or end user to know which zone their area falls within. It is recommended a qualified person is engaged to complete a risk analysis and classify the area in accordance with standard IEC Gas & vapours Dust Description Zone 0 Ga Zone 20 Da An area in which an explosive atmosphere is continuously present or for long periods or frequently Zone 1 Gb Zone 2 Gc Zone 21 Db Zone 22 Dc An area in which an explosive atmosphere is likely to occur occasionally in normal operation. An area in which an explosive atmosphere is not likely to occur in normal operation. The hazardous areas are classified in the table above according to IEC and IEC brenclosures.com.au Hazardous Areas 13
16 TECHNICAL INFORMATION Gas Groups Electrical apparatus for use in areas with flammable gases and vapours are divided into groups: Group I electrical equipment used in underground coal mining Group II electrical equipment used in petrochemical industries Group II is subdivided into 3 groups based on their explosive properties (see table below). Groups Group I Group IIA Group IIB Group IIC Representative Gas Methane Propane Ethylene Hydrogen, Acetylene, Carbon Disulphide Temperature or 'T Rating' Temperature for Ignition Hot surfaces are a potential ignition source in hazardous applications. Hazardous materials will have different minimum temperatures at which ignition becomes a danger. Electrical equipment for hazardous areas is tested and allocated a T Rating based on the maximum temperature of the equipment. The T Rating must always have a lower maximum temperature than the ignition temperature of the gas group present. Table 1: provides a summary of the maximum temperatures for the different ratings. T Rating Maximum Temperature T1 450ºC T2 300ºC T3 200ºC T4 135ºC T5 100ºC T6 85ºC Table 2: provides some examples of the ignition temperatures and T Ratings for gases. Example Gas Ignition Temperature T Rating Methane 580ºC T1 Hydrogen 500ºC T1 Kerosene 295ºC T3 Petroleum 400ºC T2 Carbon Disulphide 95ºC T6 Diethyl Ether 160ºC T4 Ethyl Nitrite 95ºC T6 Hydrogen Sulphide 270ºC T3 14 Hazardous Areas
17 TECHNICAL INFORMATION Dust Combustible Dust Dust fibres or flyings, which are combustible or ignitable when mixed with air are known as combustible dusts. Dust explosions may be initiated by ignition of a cloud of dust. It is not unusual for an explosion, which starts from the ignition of a dust layer, to cause the dislodging of dust accumulated on various surfaces, which then leads to a dust cloud explosion. Table 3: Characteristics of some common combustible dusts Ignition temperature Material Minimum ignition energy (mj) Cloud, ºC Layer, ºC Aluminium Coal, Pittsburg (experimental mine coal) Rice Sugar Wheatflour NOTE: The data given in this table is derived from AS :1986 (superseded by AS/NZS which is superseded by AS/NZS ) Protection Methods Types of explosion protection for electrical equipment. Type of Protection Principle Standard Zone Ex d Ex p Ex q Ex o Ex e Ex i Ex n Flameproof Enclosure Pressurised Enclosures Powder Filling Oil Immersion Increased Safety Intrinsic Safety Non sparking Containment explosion within an enclosure will not be propogated outside the enclosure. Enclosure in a protective gas is maintained at a pressure greater than that of the external atmosphere. Mounting of potentially incendive components in an enclosure filled with quartz or solid glass particles. Equipment or parts are immersed in protective liquid such as oil. The protective liquid acts as an insulating medium. Non sparking components are designed to substantially reduce the likelihood of the occurrence of fault conditions which could cause ignition. The potential spark energy of a circuit is reduced to below the amount required for ignition. Electrical apparatus in normal operating conditions and in certain specified abnormal conditions, that is not capable of igniting a surrounding explosive gas atmosphere. IEC Zone 1 & 2 IEC Zone 1 & 2 IEC Zone 1 & 2 IEC Zone 1 & 2 IEC Zone 1 & 2 IEC Zone 0, 1 & 2 IEC Zone 2 Ex m Encapsulation Parts that are capable of igniting an explosive atmosphere by either sparking or heating, are enclosed in a compound so that the explosive atmosphere cannot be ignited under operating or installation conditions. IEC Zone 0, 1 & 2 Ex t Dust Protection by Enclosure Electrical equipment is protected by the enclosure and surface temperature limitation for use in explosive and dust atmospheres. IEC Zone 20, 21 & 22 brenclosures.com.au Hazardous Areas 15
18
19 Aluminium Ex d Enclosures
20 ALUMINIUM EX D ENCLOSURES ZONES 1 & 2, 21 & 22 MATERIALS Body Marine grade copper free aluminium body and cover Fixings Stainless steel external screws Mounting plate Hot dip galvanised steel or aluminium INCLUSIONS Customised etched identification label Earth stud Hinged lid Entries, terminals and operators arranged to suit customer requirements OPTIONS External epoxy painting with colour on request Internal anti-condensate painting orange RAL-2004 O-ring gaskets and glass windows on cover Drain and breather valves AMBIENT TEMPERATURE -60ºC ~ 130ºC CONFORMITY IECEx :2007 IECEx :2007 IECEx :2006 IECEx :2008 IP 66 OVERVIEW The rectangular Ex d enclosure is constructed from aluminium alloy and is suitable for use in hazardous areas with the most demanding conditions. These enclosures are designed to house terminals, electrical equipment and cable terminations. They can be configured for custom built applications such as motor starters, circuit breakers and local control stations. Suitable for application across many industries where reliability and safety are of the highest priority such as offshore, mining and metals, marine, oil & gas, petrochemical and manufacturing industries. PROTECTION Terminal Boards Ex db IIB+H2 T6-T3 Ex db [ia/ib] IIB+H2 T6-T3 Extb IIIC T85ºC T150ºC Power Units II 2 G Ex d IIB+H2 T6-T3 II2 D ex td A21 T85ºC-150ºC Control and signalling II2 G Ex d IIB+H2 T6-T3 II2 (1) G Ex d [ia] IIB+H2 T6-T3 II2 (2) G Ex d [ib] IIB+H2 T6-T3 II2 D Ex td A21 T85ºC-150ºC TERMINAL INFORMATION (Reference Guide Only) Catalogue No. Terminals 2.5mm 2 6.0mm mm mm mm mm mm mm 2 Max. number of operators FEJB x 1 8 x 1 6 x 1 4 x 1 2 x 1 6 FEJB x 1 20 x 1 14 x 1 12 x 1 8 x 1 6 x 1 2 x 1 1 x 1 12 FEJB x 1 30 x 1 20 x 1 18 x 1 12 x 1 10 x 1 4 x 1 2 x 1 12 FEJB x 1 22 x 1 16 x 1 14 x 1 11 x 1 9 x 1 7 x 1 2 x 1 16 FEJB x 2 32 x 2 24 x 2 20 x 2 14 x 2 12 x 1 8 x 1 4 x 1 30 FEJB x 2 32 x 2 24 x 2 20 x 2 14 x 2 12 x 1 8 x 1 4 x 1 30 FEJB x 2 46 x 2 36 x 2 30 x 2 22 x 2 18 x 2 16 x 1 6 x 1 54 FEJB x 3 58 x 3 46 x 3 38 x 3 28 x 3 26 x 2 22 x 2 12 x 1 56 FEJB x 3 58 x 3 46 x 3 38 x 3 28 x 3 26 x 2 22 x 2 12 x 1 56 FEJB x 3 70 x 3 56 x 3 46 x 3 34 x 3 28 x 2 24 x 2 12 x 1 48 FEJB x 3 70 x 3 56 x 3 46 x 3 34 x 3 28 x 2 24 x 2 12 x 1 48 FEJB x 3 90 x 3 70 x 3 60 x 3 44 x 3 36 x 3 32 x 2 14 x 2 54 FEJB x 3 90 x 3 70 x 3 60 x 3 44 x 3 36 x 3 32 x 2 14 x Hazardous Areas
21 ALUMINIUM EX D ENCLOSURES ZONES 1 & 2, 21 & 22 Aluminium Ex d Enclosures SELECTION GUIDE Dimensions (mm) Fixings (mm) Internal Dimensions (mm) Catalogue No. Height (A) Width (B) Depth (D) Height (E) Width (F) Height (H) Width (G) Depth Weight (kg) FEJB FEJB FEJB FEJB FEJB FEJB FEJB FEJB FEJB FEJB FEJB FEJB FEJB THREAD SIZE TABLE Size UNI 6125 ISO 228/1 ASA B2.1 ISO 965/I 1 GK ½" G ½ ½" NPT M20 2 GK ¾" G ¾" ¾" NPT M25 3 GK 1" G 1" 1" NPT M32 4 GK 1¼" G 1¼" 1¼" NPT M40 5 GK 1½" G 1½" 1½" NPT M50 6 GK 2" G 2" 2" NPT M63 7 GK 2½" G 2½" 2½" NPT M75 8 GK 3" G 3" 3" NPT M85 DRILLING LAYOUT Drilling Area (mm) Width Quantity allowed entries for size Height Quantity allowed entries for size Catalogue No. A B C D FEJB FEJB FEJB FEJB FEJB FEJB FEJB FEJB FEJB FEJB FEJB FEJB FEJB TECHNICAL DRAWINGS B F A B E Dilling layout front view C D A E H D G F Dilling layout cover Dilling layout side view brenclosures.com.au Hazardous Areas 19
22
23 Enclosures
24 SLOPING ROOF TERMINAL BOX ZONES 1 & 2, 21 & 22 MATERIALS Body 316 stainless steel Body thickness 1.5mm Fixings 316 stainless steel Surface finish N4 INCLUSIONS Steel mounting pan 7mm stainless steel lock External mounting flange Internal and external 6mm or 8mm earth stud 3mm stainless steel gland plate Earth strap kit CERTIFICATION IECEx ITA x PROTECTION Ex e IIC T6 Gb Ex na IIC T6 Gb, Zone 2 only Ex de IIC T6 Gb Ex td A21/22 T80ºC DIP A21/22 Ta80ºC Ex t IIIC T80ºC Db AMBIENT TEMPERATURE -20ºC ~ +40ºC (to +55ºC) Australian Made Australian Owned IP 65/66/67 OVERVIEW Suitable for use in hazardous areas with the most demanding conditions. The 40º sloping roof minimises the build up of solids on the roof of the enclosure. The 40mm overhang ensures material that slides off the roof is directed away from the top of the door. A complete arrangement of terminals can be fitted ranging from 2.5mm to 300mm. This enclosure also caters for IS terminals. FEATURES Customised etched identification label 40º sloping roof and 40mm overhang Keyed entry with 7mm stainless steel square lock Other labelling options available Threaded entries in gland plate versions IP66 windows available Brass gland plate option with up to 3 gland plates available TECHNICAL DRAWINGS B F E A Is indicative of lock position when there is only one lock on enclosures G K H J D A I C L M Front View Front View With Internals Side View With Internals Bottom View With Internals 22 Hazardous Areas
25 SLOPING ROOF TERMINAL BOX ZONES 1 & 2, 21 & 22 SELECTION GUIDE! These enclosures are sold with controls and terminals fitted. Empty enclosures are not available for sale. Contact your local sales engineer to discuss your specific requirements. Terminal Boxes Dimensions (mm) External Mounting Centres Opening Usable Depth Mounting Pan Gland Opening Gland Plate Catalogue No. Description A B C D E F G H I J K L M Width Depth No. of Locks TBKS030215/G TBKS030420/G TBKS040315/G TBKS040420/G TBKS040620/G TBKS040630/G0 No gland plate TBKS060420/G TBKS060630/G TBKS080620/G TBKS080630/G TBKS100620/G TBKS120830/G TBKS TBKS TBKS TBKS TBKS TBKS x bottom gland plate TBKS TBKS TBKS TBKS TBKS TBKS TBKS030215/G TBKS030420/G TBKS040315/G TBKS040420/G TBKS040620/G TBKS040630/G3 1 bottom gland plate, TBKS060420/G3 2 side gland plates TBKS060630/G TBKS080620/G TBKS080630/G TBKS100620/G TBKS120830/G TERMINAL INFORMATION (Reference Guide ONLY) Terminal Size Catalogue No. 20A 2.5mm2 Derated to 10A 28A 36A 50A 109A 2.5mm2 1A TBKS TBKS TBKS TBKS TBKS TBKS TBKS TBKS TBKS TBKS TBKS TBKS Please Note: Other configurations and terminal sizes available, please contact your local B&R sales office for evaluation and wattage calculations. Quantities for instrumentation has been determined based on 1Amp with consideration to the size of the enclosure. brenclosures.com.au Hazardous Areas 23
26 FLAT ROOF TERMINAL BOX ZONES 1 & 2, 21 & 22 MATERIALS Body 316 stainless steel Body thickness 1.5mm Fixings 316 stainless steel Surface finish N4 INCLUSIONS Steel mounting pan 3mm stainless steel or 6mm brass gland plate 7mm stainless steel lock Internal and external 6mm or 8mm earth stud Earth strap kit Stainless steel label bracket CERTIFICATION IECEx ITA x PROTECTION Ex e IIC T6 Gb Ex na IIC T6 Gc Ex de IIC T6 Gb Ex td A21/22 T80ºC DIP A21/22 Ta80ºC Ex t IIIC T80ºC Db AMBIENT TEMPERATURE -20ºC ~ +40ºC / 55ºC option Australian Made Australian Owned IP 65/66/67 OVERVIEW The flat roof keyed terminal box is made from 316 stainless steel and is suitable for use in hazardous areas with the most demanding conditions. The enclosures are suitable for Zones 1 & 2, 21 & 22 applications where flammable liquids, gases & vapours or combustible dusts are frequently present. A complete arrangement of terminals can be fitted ranging from 2.5mm to 300mm.This enclosure also caters for IS terminals. FEATURES Customised etched identification label Keyed entry with 7mm square stainless steel lock Steel mounting pan Internal and external 6mm earth stud, 8mm option Replaceable gaskets Wall-mounting brackets M8 fixings Other label options available Threaded entries on gland plate versions IP66 windows availble Brass gland plate option up to 3 gland plates available TECHNICAL DRAWINGS B C H A Is indicative of lock position when there is one lock on enclosure E G D Front View Front View With Internals Side View Bottom View 24 Hazardous Areas
27 FLAT ROOF TERMINAL BOX ZONES 1 & 2, 21 & 22 SELECTION GUIDE! These enclosures are sold with controls and terminals fitted. Empty enclosures are not available for sale. Contact your local sales engineer to discuss your specific requirements. Terminal Boxes Dimensions (mm) External Opening Mounting Pan Gland Opening Gland Plate Wall Mount Brackets Catalogue No. Description A B C D E F G H I J K Width Depth TBKF030215/G TBKF030420/G TBKF040315/G TBKF040420/G TBKF040620/G TBKF040630/G0 No gland plate TBKF060420/G TBKF060630/G TBKF080620/G TBKF080630/G TBKF100620/G TBKF120830/G TBKF TBKF TBKF TBKF TBKF TBKF x bottom gland plate TBKF TBKF TBKF TBKF TBKF TBKF TBKF030215/G TBKF030420/G TBKF040315/G TBKF040420/G TBKF040620/G TBKF040630/G3 1 bottom gland plate, TBKF060420/G3 2 side gland plates TBKF060630/G TBKF080620/G TBKF080630/G TBKF100620/G TBKF120830/G No of Locks TERMINAL INFORMATION (Reference Guide ONLY) Terminal Size Catalogue No. 20A 2.5mm2 Derated to 10A 28A 36A 50A 109A 2.5mm2 1A TBKF TBKF TBKF TBKF TBKF TBKF TBKF TBKF TBKF TBKF TBKF TBKF Please Note: Other configurations and terminal sizes available, please contact your local B&R sales office for evaluation and wattage calculations. Quantities for instrumentation has been determined based on 1Amp with consideration to the size of the enclosure. brenclosures.com.au Hazardous Areas 25
28 FLAT ROOF TERMINAL BOX ZONES 1 & 2, 21 & 22 MATERIALS Body 316 stainless steel Body thickness 1.5mm Fixings 316 stainless steel Surface finish N4 INCLUSIONS Mounting flanges External earth stud Internal earth strap kit CERTIFICATION IECEx ITA x PROTECTION Ex e IIC T6 Gb Ex na IIC T6 Gc Ex de IIC T6 Gb Ex td A21/22 T80ºC DIP A21/22 Ta80ºC Ex t IIIC T80ºC Db AMBIENT TEMPERATURE -20ºC ~ +40ºC / 55ºC option Australian Made Australian Owned IP 65/66/67 OVERVIEW The flat roof screwed terminal box is made from 316 stainless steel and is suitable for use in hazardous areas with the most demanding conditions. These enclosures are suitable for Zones 1&2, 21&22 applications where flammable liquids, gases & vapours or combustible dusts are frequently present. FEATURES Customised etched identification label Screwed lid Mounting flanges Mounting pan option available External earth stud Stainless steel fixings Internal earth strap kit TERMINAL INFORMATION (Reference Guide ONLY) Terminal Size 2.5mm2 2.5mm2 4mm2 6mm2 2.5mm2 Catalogue 20A Derated to 36A 1A TBSF TBSF TBSF TBSF TBSF Please Note: Other configurations and terminal sizes available, please contact your local B&R sales office for evaluation and wattage calculations. Quantities for instrumentation has been determined based on 1Amp with consideration to the size of the enclosure. 10mm 2 and 35mm 2 available on request, cable / entry size to be considered. 26 Hazardous Areas
29 FLAT ROOF TERMINAL BOX ZONES 1 & 2, 21 & 22 Dimensions (mm) Fixings (mm) Opening Height Width Depth Usable Depth Distance from Wall Height Width Height Width Catalogue No. (A) (B) (C) (D) (E) (F) (G) (H) (I) No. of Fixings TBSF TBSF TBSF TBSF TBSF TECHNICAL DRAWINGS B G ø8.5 hole size F A I H SELECTION GUIDE! These enclosures are sold with controls and terminals fitted. Empty enclosures are not available for sale. Contact your local sales engineer to discuss your specific requirements. Terminal Boxes E C D 6mm earth stud Front View Front View With Internals Side View brenclosures.com.au Hazardous Areas 27
30 STAINLESS STEEL TERMINAL BOX ZONES 1 & 2, 21 & 22 MATERIALS Body 316 stainless steel Body thickness 1.5mm Fixings 316 stainless steel Surface finish N4 INCLUSIONS Mounting flanges External earth stud Internal earth strap kit CERTIFICATION IECEx ITA x PROTECTION Ex e IIC T6 Gb Ex na IIC T6 Gc Ex de IIC T6 Gb Ex td A21/22 T80ºC DIP A21/22 Ta80ºC Ex t IIIC T80ºC Db AMBIENT TEMPERATURE -20ºC ~ +55ºC Australian Made Australian Owned IP 65/66 OVERVIEW The flat roof screwed terminal box is made from 316 stainless steel and is suitable for use in hazardous areas with the most demanding conditions. These enclosures are suitable for Zones 1 & 2, 21 & 22 applications where flammable liquids, gases & vapours or combustible dust are frequently present. FEATURES Customised etched identification label Screwed lid Mounting flanges Stainless steel fixings Earth strap kit Optional steel mounting pan 28 Hazardous Areas
31 STAINLESS STEEL TERMINAL BOX ZONES 1 & 2, 21 & 22 SELECTION GUIDE! These enclosures are sold with controls and terminals fitted. Empty enclosures are not available for sale. Contact your local sales engineer to discuss your specific requirements. Terminal Boxes External Dimensions (mm) Fixings (mm) Lid Fixings (mm) Height Width Depth Distance from wall Height Width Height Width Catalogue No. Description (A) (B) (C) (D) (E) (F) (G) (H) TBSFCS11 Single gang TBSFCS12 Double gang TBSFCS13 Three gang TBSFCS14 Four gang TBSFCS16 Six gang TECHNICAL DRAWINGS B H C F D A E G G Front View Side View Section View brenclosures.com.au Hazardous Areas 29
32 SLOPING ROOF CUSTOM BUILT CONTROL BOX ZONES 1 & 2, 21 & 22 MATERIALS Body 316 stainless steel Body thickness 1.5mm Fixings 316 stainless steel Surface finish N4 INCLUSIONS Steel mounting pan 7mm stainless steel lock External mounting flange Internal and external 6mm or 8mm earth stud 3mm stainless steel gland plate Earth strap kit No gland plate option CERTIFICATION IECEx ITA x PROTECTION Ex e IIC T6 Gb Ex na IIC T6 Gb, Zone 2 only Ex de IIC T6 Gb Ex td A21/22 T80ºC DIP A21/22 Ta80ºC Ex t IIIC T80ºC Db AMBIENT TEMPERATURE -20ºC ~ +40ºC (to +55ºC) Australian Made Australian Owned IP 65/66 OVERVIEW Suitable for use in hazardous areas with the most demanding conditions. The 40º sloping roof minimises the build up of solids on the roof of the enclosure. The 40mm overhang ensures material that slides off the roof is directed away from the top of the door. FEATURES Customised etched identification label 40º sloping roof and 40mm overhang Keyed entry with 7mm stainless steel square lock Other labelling options available Threaded entries in gland plate versions IP66 windows available Brass gland plate option with up to 3 gland plates available CONTROLS / OPERATORS Other controls / operators are available including: Pushbuttons Isolating switches Key switches Pilot lights Ammeters Circuit breakers Motor starters Viewing windows 30 Hazardous Areas
33 SLOPING ROOF CUSTOM BUILT CONTROL BOX ZONES 1 & 2, 21 & 22 SELECTION GUIDE! These enclosures are sold with controls and terminals fitted. Empty enclosures are not available for sale. Contact your local sales engineer to discuss your specific requirements. Dimensions (mm) External Mounting Centres Opening Usable Depth Mounting Pan Gland Opening Gland Plate No of Catalogue No. Description A B C D E F G H I J K L M Width Depth locks CBKS030215/G CBKS030420/G CBKS040315/G CBKS040420/G CBKS040620/G CBKS040630/G0 No gland plate CBKS060420/G CBKS060630/G CBKS080620/G CBKS080630/G CBKS100620/G CBKS120830/G CBKS CBKS CBKS CBKS CBKS CBKS x bottom gland plate CBKS CBKS CBKS CBKS CBKS CBKS CBKS030215/G CBKS030420/G CBKS040315/G CBKS040420/G CBKS040620/G CBKS040630/G3 1 bottom gland plate, CBKS060420/G3 2 side gland plates CBKS060630/G CBKS080620/G CBKS080630/G CBKS100620/G CBKS120830/G Control Boxes TECHNICAL DRAWINGS B F E A Is indicative of lock position when there is only one lock on enclosures G K H J D A I C L M Front View Front View Side View Bottom View With Internals With Internals With Internals brenclosures.com.au Hazardous Areas 31
34 FLAT ROOF CUSTOM BUILT CONTROL BOX ZONES 1 & 2, 21 & 22 MATERIALS Body 316 stainless steel Body thickness 1.5mm Fixings 316 stainless steel Surface finish N4 INCLUSIONS Steel mounting pan 3mm stainless steel or 6mm brass gland plate 7mm stainless steel lock Internal and external 6mm or 8mm earth stud Earth strap kit Stainless steel label bracket CERTIFICATION IECEx ITA x PROTECTION Ex e IIC T6 Gb Ex na IIC T6 Gc Ex de IIC T6 Gb Ex td A21/22 T80ºC DIP A21/22 Ta80ºC Ex t IIIC T80ºC Db AMBIENT TEMPERATURE -20ºC ~ +40ºC / 55ºC option Australian Made Australian Owned IP 65/66 OVERVIEW The flat roof keyed control box is made from 316 stainless steel and is suitable for use in hazardous areas with the most demanding conditions. The enclosures are suitable for Zones 1 & 2, 21 & 22 applications where flammable liquids, gases & vapours or combustible dusts are frequently present CONTROLS / OPERATORS Other controls / operators are available including: Pushbuttons Isolating switches Key switches Pilot lights Ammeters Circuit breakers Motor starters Viewing windows FEATURES Customised etched identification label Keyed entry with 7mm square stainless steel lock Steel mounting pan Internal and external 6mm earth stud, 8mm option Replaceable gaskets Wall-mounting brackets M8 fixings Other label options available Threaded entries on gland plate versions IP66 windows availble Brass gland plate option up to 3 gland plates available 32 Hazardous Areas
35 FLAT ROOF CUSTOM BUILT CONTROL BOX ZONES 1 & 2, 21 & 22 SELECTION GUIDE! These enclosures are sold with controls and terminals fitted. Empty enclosures are not available for sale. Contact your local sales engineer to discuss your specific requirements. Dimensions (mm) External Opening Mounting Pan Gland Opening Gland Plate Wall Mount Brackets Catalogue No. Description A B C D E F G H I J K Width Depth CBKF030215/G CBKF030420/G CBKF040315/G CBKF040420/G CBKF040620/G CBKF040630/G0 No gland plate CBKF060420/G CBKF060630/G CBKF080620/G CBKF080630/G CBKF100620/G CBKF120830/G CBKF CBKF CBKF CBKF CBKF CBKF x bottom gland plate CBKF CBKF CBKF CBKF CBKF CBKF CBKF030215/G CBKF030420/G CBKF040315/G CBKF040420/G CBKF040620/G CBKF040630/G3 1 bottom gland plate, CBKF060420/G3 2 side gland plates CBKF060630/G CBKF080620/G CBKF080630/G CBKF100620/G CBKF120830/G No of Locks Control Boxes TECHNICAL DRAWINGS B C H A Is indicative of lock position when there is one lock on enclosure E G D Front View Front View Side View Bottom View With Internals brenclosures.com.au Hazardous Areas 33
36 FLAT ROOF CUSTOM BUILT CONTROL BOX ZONES 1 & 2, 21 & 22 MATERIALS Body 316 stainless steel Body thickness 1.5mm Fixings 316 stainless steel Surface finish N4 INCLUSIONS Mounting flanges External earth stud Internal earth strap kit CERTIFICATION IECEx ITA x PROTECTION Ex e IIC T6 Gb Ex na IIC T6 Gc Ex de IIC T6 Gb Ex td A21/22 T80ºC DIP A21/22 Ta80ºC Ex t IIIC T80ºC Db AMBIENT TEMPERATURE -20ºC ~ +40ºC / 55ºC option Australian Made Australian Owned IP 65/66 OVERVIEW The flat roof screwed terminal box is made from 316 stainless steel and is suitable for use in hazardous areas with the most demanding conditions. These enclosures are suitable for Zones 1 & 2, 21 & 22 applications where flammable liquids, gases & vapours or combustible dusts are frequently present. FEATURES Customised etched identification label Screwed lid Mounting flanges Mounting pan option available External earth stud Stainless steel fixings Internal earth strap kit 34 Hazardous Areas
37 FLAT ROOF CUSTOM BUILT CONTROL BOX ZONES 1 & 2, 21 & 22 Dimensions (mm) Fixings (mm) Opening Height Width Depth Usable Depth Distance from Wall Height Width Height Width Catalogue No. (A) (B) (C) (D) (E) (F) (G) (H) (I) No. of Fixings CBSF CBSF CBSF CBSF CBSF B G ø8.5 hole size F A I H SELECTION GUIDE! These enclosures are sold with controls and terminals fitted. Empty enclosures are not available for sale. Contact your local sales engineer to discuss your specific requirements. Control Boxes TECHNICAL DRAWINGS E C D 6mm earth stud Front View Front View With Internals Side View brenclosures.com.au Hazardous Areas 35
38 STAINLESS STEEL CONTROL STATION ZONES 1 & 2, 21 & 22 MATERIALS Body 316 stainless steel Body thickness 1.5mm Gasket Replaceable Fixings 316 stainless steel Surface finish N4 Components Certified switch mechanisms, ammeter available INCLUSIONS Earth strap kit CERTIFICATION IECEx ITA x PROTECTION Ex e IIC T6 Gb Ex na IIC T6 Gc Ex de IIC T6 Gb Ex td A21/22 T80ºC DIP A21/22 Ta80ºC Ex t IIIC T80ºC Db AMBIENT TEMPERATURE -20ºC ~ +40ºC / 55ºC option Australian Made Australian Owned IP 66 OVERVIEW Control stations are manufactured from 316 stainless steel. These control stations are available pre-configured or custom-built for ease of installation from one to six operators. FEATURES Customised etched identification label Screwed lid Mounting flanges Stainless steel fixings Earth strap kit TECHNICAL DRAWINGS B C A Front View Side View Section View 36 Hazardous Areas
39 STAINLESS STEEL CONTROL STATION ZONES 1 & 2, 21 & 22 SELECTION GUIDE! These enclosures are sold with controls and terminals fitted. Empty enclosures are not available for sale. Contact your local sales engineer to discuss your specific requirements. Dimensions (mm) Catalogue No. Type Pole Height (A) Width (B) Depth (C) Description CSS1-P1GRN NO+1NC, Start, Green CSS1-P1RED NO+1NC, Stop, Red CSS1-P3MH NO+1NC, emergency stop self-locking CSS1-P2 Pushbutton NO+1NC, double button, Stop-Start CSS1-P NO+1NC, mushroom head button, Black CSS2-PGPR NO+1NC, 2 pushbuttons Green/Red CSS3-PGPRPB NO+1NC, 3 pushbuttons Green/Red/Black CSS2-P1GRNLR NO+1NC, Start, lamp, Red CSS2-P1REDLR NO+1NC, Stop, lamp, Red CSS2-P1GRNLG NO+1NC, Start, lamp, Green CSS2-P1REDLG NO+1NC, Stop, lamp, Green CSS2-P2GRNLY Pushbutton NO+1NC, Start, lamp, Yellow CSS2-P1REDLY & Lamp NO+1NC, Stop, lamp, Yellow CSS2-P1GRNLB NO+1NC, Start, lamp, Blue CSS2-P1REDLB NO+1NC, Stop, lamp, Blue CSS2-P1GRNLW NO+1NC, Start, lamp, White CSS2-P1REDLW NO+1NC, Stop, lamp, White CSS3-PGPRLR NO+1NC, 2 pushbuttons Green/Red, lamp Red CSS3-PGPRLG NO+1NC, 2 pushbuttons Green/Red, lamp Green CSS3-PGPRLY NO+1NC, 2 pushbuttons Green/Red, lamp Yellow CSS3-PGPRLB NO+1NC, 2 pushbuttons Green/Red, lamp Blue CSS3-PGPRLW Double Pushbutton NO+1NC, 2 pushbuttons Green/Red, lamp White CSS3-P2P3MHLR w/ Lamp NC, double pushbutton Red, emergency lamp Red CSS3-P2P3MHLG NC, double pushbutton Red, emergency lamp Green CSS3-P2P3MHLY NC, double pushbutton Red, emergency lamp Yellow CSS3-P2P3MHLB NC, double pushbutton Red, emergency lamp Blue CSS3-P2P3MHLW NC, double pushbutton Red, emergency lamp White CSS1-LR AC24~240V, single lamp, Red CSS1-LG AC24~240V, single lamp, Green CSS1-LY Lamp AC24~240V, single lamp, Yellow CSS1-LB AC24~240V, single lamp, Blue CSS1-LW AC24~240V, single lamp, White CSS2-P2LR NO+1NC, AC24~240V, double pushbutton, lamp Red CSS2-P2LG NO+1NC, AC24~240V, double pushbutton, lamp Green CSS2-P2LY NO+1NC, AC24~240V, double pushbutton, lamp Yellow CSS2-P2LB NO+1NC, AC24~240V, double pushbutton, lamp Blue CSS2-P2LW NO+1NC, AC24~240V, double pushbutton, lamp White Double Lamp CSS3-P2LR NO+1NC, Red CSS3-P2LG NO+1NC, Green CSS3-P2LY NO+1NC, Yellow CSS3-P2LB NO+1NC, Blue CSS3-P2LW NO+1NC, White CSS1-K6 2-p Small handle, Ø39mm CSS2-S6 Switch 2-p Large handle, Ø60mm CSS2-S6H4 4-p NO+2NC, LL 0 Control Boxes brenclosures.com.au Hazardous Areas 37
40 MATERIALS Body GRP UV stabilised anti-static Stainless steel screws Internal gland plate Surface finish Textured matt black INCLUSIONS Standard built product Internal brass gland plates CERTIFICATION IECEx CQM NON-METALLIC CONTROL STATION ZONES 1 & 2, 21 & 22 PROTECTION Ex ed IIC T6 Ex td A21 IP66 T80ºC AMBIENT TEMPERATURE -40 Ta 40ºC IP 66 OVERVIEW Range of standard control stations that can be combined into one unit using a maximum of six in configurations to suit the application requirements. They are light-weight, impact resistant and are suitable for use in hazardous areas where stainless steel is not a requirement. FEATURES Can be customised to suit requirements UV stabilised anti-static construction Five standard controllers in one Easy installation Flexible configurations High chemical stability TECHNICAL DRAWINGS B E c A D Front View Side View 38 Hazardous Areas
41 NON-METALLIC CONTROL STATION ZONES 1 & 2, 21 & 22 SELECTION GUIDE Dimensions (mm) Mounting Centres (mm) Catalogue No. Pole Height (A) Width (B) Depth (C) Height (D) Width (E) Description CSG1-P1GRN NO+1NC, Start, Green CSG1-P1RED NO+1NC, Stop, Red CSG1-P3MH NO+1NC, emergency stop self-locking, CSG1-P2 Pushbutton NO+1NC, double button, Stop-Start CSG1-P NO+1NC, mushroom head button, Black CSG2-PGPR NO+1NC, 2 pushbuttons CSG3-PGPRPB NO+1NC, 3 pushbuttons CSG2-P1GRNLR NO+1NC, Start, lamp, Red CSG2-P1REDLR NO+1NC, Stop, lamp, Red CSG2-P1GRNLG NO+1NC, Start, lamp, Green CSG2-P1REDLG NO+1NC, Stop, lamp, Green CSG2-P2GRNLY NO+1NC, Start, lamp, Yellow CSG2-P1REDLY NO+1NC, Stop, lamp, Yellow CSG2-P1GRNLB NO+1NC, Start, lamp, Blue CSG2-P1REDLB Pushbutton & Lamp NO+1NC, Stop, lamp, Blue CSG2-P1GRNLW NO+1NC, Start, lamp, White CSG2-P1REDLW NO+1NC, Stop, lamp, White CSG3-PGPRLR NO+1NC, 2 pushbuttons, lamp, Red CSG3-PGPRLG NO+1NC, 2 pushbuttons, lamp, Green CSG3-PGPRLY NO+1NC, 2 pushbuttons, lamp, Yellow CSG3-PGPRLB NO+1NC, 2 pushbuttons, lamp, Blue CSG3-PGPRLW NO+1NC, 2 pushbuttons, lamp, White CSG3-P2P3MHLR NC, Red emergency lamp, Red CSG3-P2P3MHLG NC, Red emergency lamp, Green CSG3-P2P3MHLY Double Pushbutton w/ Lamp NC, Red emergency lamp, Yellow CSG3-P2P3MHLB NC, Red emergency lamp, Blue CSG3-P2P3MHLW NC, Red emergency lamp, White CSG1-LR AC24~240V, single lamp, Red CSG1-LG AC24~240V, single lamp, Green CSG1-LY Lamp AC24~240V, single lamp, Yellow CSG1-LB AC24~240V, single lamp, Blue CSG1-LW AC24~240V, single lamp, White CSG2-P2LR NO+1NC, AC24~240V, double lamp, Red CSG2-P2LG NO+1NC, AC24~240V, double lamp, Green CSG2-P2LY NO+1NC, AC24~240V, double lamp, Yellow CSG2-P2LB NO+1NC, AC24~240V, double lamp, Blue CSG2-P2LW NO+1NC, AC24~240V, double lamp, White Double Pushbutton CSG3-P2LR NO+1NC, Red CSG3-P2LG NO+1NC, Green CSG3-P2LY NO+1NC, Yellow CSG3-P2LB NO+1NC, Blue CSG3-P2LW NO+1NC, White CSG1-K6 2-p Small handle, Ø39mm CSG2-S6 Switch 2-p Large handle, Ø60mm CSG2-S6H4 4-p NO+2NC, LL 0 Non-Metallic Enclosures brenclosures.com.au Hazardous Areas 39
42 MATERIALS Body GRP anti-static Surface finish Textured matt black INCLUSIONS Custom built to suit requirements CERTIFICATION IECEx CQM x PROTECTION Ex e II T6/T5 Gb Ex td A21 IP65 T95ºC ~ T80ºC AMBIENT TEMPERATURE -40ºC + 40ºC / 55ºC option IP 65 OVERVIEW A range of non-metallic enclosures which are impact resistant, withstand high or low termperatures and are static resistant. These terminal boxes are suitable for use in hazardous area environments to provide the ultimate in flexibility and are easy to wire and mount. A complete arrangement of terminals can be fitted ranging from 2.5mm to 300mm. The enclosure can also cater for IS terminals. FEATURES Earth plate for cable gland entries Used for terminating wires for various electrical apparatus and instruments in circuits Can be used with with IS terminations Ex e models must use component certified terminals TECHNICAL DRAWINGS A NON-METALLIC TERMINAL BOX ZONES 1 & 2, 21 & 22 B C Front View Side View 40 Hazardous Areas
43 NON-METALLIC TERMINAL BOX ZONES 1 & 2, 21 & 22 SELECTION GUIDE! These enclosures are sold with controls and terminals fitted. Empty enclosures are not available for sale. Contact your local sales engineer to discuss your specific requirements. Height Width Depth Catalogue No. (A) (B) (C) TBG TBG TBG TBG TBG TBG052 TBG053 TBG Dimensions (mm) Entries Terminals Size From side A, B or Z, Y From side C, D or S, X No. of Rows 2.5mm 4mm 6mm 10mm 16mm 32mm M M M M M M M M M M TBG TBG072 TBG073 TBG TBG TBG082 TBG083 TBG084 TBG085 TBG092 TBG093 TBG M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M Non-Metallic Enclosures brenclosures.com.au Hazardous Areas 41
44 NON-METALLIC TERMINAL BOX ZONES 1 & 2, 21 & 22 MATERIALS Body GRP anti-static Surface finish Textured matt black INCLUSIONS Built in terminal box Brass gland plate Certified plugs Custom built to suit requirements CERTIFICATION IECEx CQM x PROTECTION Ex e II T6 Gb Ex td A21 T80ºC AMBIENT TEMPERATURE -40ºC Ta +40ºC IP 66 OVERVIEW A range of non-metallic enclosures which are impact resistant, withstand high or low termperatures and static resistant. These terminal boxes are suitable for use in hazardous area environments, provide the ultimate in flexibility and are easy to wire and mount. FEATURES Impact and static resistant Withstand high or low temperatures Cable can connect to terminals from different directions TECHNICAL DRAWINGS A B C Front View Side View 42 Hazardous Areas
45 NON-METALLIC TERMINAL BOX ZONES 1 & 2, 21 & 22 SELECTION GUIDE! These enclosures are sold with controls and terminals fitted. Empty enclosures are not available for sale. Contact your local sales engineer to discuss your specific requirements. Dimensions (mm) Entries Terminals Catalogue No. Protection Type Height (A) Width (B) Depth (C) Qty Size (mm) Location Qty Size (mm) TBGS21ET2.5X4/220N Opposite sides TBGS21ET2.5X4/420X One each side TBGS21ET2.5X4/225N Opposite sides TBGS21ET2.5X4/425X One each side TBGS22ET2.5X8/220N Opposite sides TBGS22ET2.5X8/420X One each side Ex e TBGS22ET2.5X8/225N Opposite sides TBGS22ET2.5X8/425X One each side TBGS22ET4X4/220N Opposite sides 4 4 TBGS22ET4X4/420X One each side 4 4 TBGS22ET4X4/225N Opposite sides 4 4 TBGS22ET4X4/425X One each side 4 4 TBGS21TT2.5X4/220N Opposite sides TBGS21TT2.5X4/420X One each side TBGS21TT2.5X4/225N Opposite sides TBGS21TT2.5X4/425X One each side TBGS22TT2.5X8/220N Opposite sides TBGS22TT2.5X8/420X One each side Ex t TBGS22TT2.5X8/225N Opposite sides TBGS22TT2.5X8/425X One each side TBGS22TT4X4/220N Opposite sides 4 4 TBGS22TT4X4/420X One each side 4 4 TBGS22TT4X4/225N Opposite sides 4 4 TBGS22TT4X4/425X One each side 4 4 TBGS21IT2.5X4/220N Opposite sides TBGS21IT2.5X4/420X One each side TBGS21IT2.5X4/225N Opposite sides TBGS21IT2.5X4/425X One each side Ex i TBGS22IT2.5X8/220N Opposite sides TBGS22IT2.5X8/420X One each side TBGS22IT2.5X8/225N Opposite sides TBGS22IT2.5X8/425X One each side Non-Metallic Enclosures brenclosures.com.au Hazardous Areas 43
46
47 Lighting
48 ALUMINIUM EMERGENCY LED EXIT LIGHT ZONES 1 & 2 MATERIALS Body Die cast aluminium Diffuser Toughened glass Surface finish Epoxy powdercoated yellow Rated voltage AC V, 50Hz INCLUSIONS 1 x M20 cable gland entries Inner control circuit with over charge protection LED lamp Direction sign (various options available) CERTIFICATION IECEx LCI x PROTECTION Ex d IIC T6 AMBIENT TEMPERATURE -20ºC ~ +55ºC Range: BAY-D Series IP 65 OVERVIEW Suitable for Zones 1 & 2 applications. These light fittings can be used as a standard light during normal operations that automatically switches to emergency state (engages emergency battery) when there is a loss of power. FEATURES Long-life energy saving LED Emergency duration 180 minutes Power consumption 2W DIRECTIONAL SIGN OPTIONS A-Type B-Type C-Type D-Type E-Type F-Type G-Type 46 Hazardous Areas
49 SELECTION GUIDE Direction Sign External Dimensions (mm) Mounting Centres (mm) Height Width Depth Width Height Catalogue No. Sign Type (A) (B) (D) (E) (C) Mounting Type Weight (kg) EEALD/BA A-Type EEALD/BB B-Type EEALD/BC C-Type EEALD/BD D-Type Wall 6.4 EEALD/BE E-Type EEALD/BF F-Type EEALD/BG G-Type EEALD/ XA A-Type EEALD/ XB B-Type EEALD/ XC C-Type EEALD/ XD D-Type Ceiling 6.4 EEALD/ XE E-Type EEALD/ XF F-Type EEALD/ XG G-Type EEALD/GA A-Type EEALD/GB B-Type EEALD/GC C-Type EEALD/GD D-Type Pendant pole 6.4 EEALD/GE E-Type EEALD/GF F-Type EEALD/GG G-Type E C E C A Wall-mount option (/B) B D A B Ceiling mount option (/X) A C ALUMINIUM EMERGENCY LED EXIT LIGHT ZONES 1 & 2 LED Lighting TECHNICAL DRAWINGS B Pendant pole option (/G) brenclosures.com.au Hazardous Areas 47
50 ALUMINIUM LED LOWBAY LIGHT ZONE 1 & 2, 21 & 22 MATERIALS Body High impact resistant aluminium alloy Lamps 150W and 120W options Lamp source Osram LED Surface finish High corrosion epoxy powdercoated orange INCLUSIONS Light Fixings Mount supplied seperately CERTIFICATION IECEx CQM X PROTECTION Ex d e IIB T6 or T6 Gb Ex tb IIIC T95ºC or T80ºC Db IP66 AMBIENT TEMPERATURE -40ºC ~ +55ºC Range: Frog Series IP 66 OVERVIEW The explosion-proof LED lowbay are an energy saving light designed for use in hazardous and marine locations. The robust construction is designed to operate in salt water and corrosive environments. Suitable for use within chemical, petrochemical, dust and grain applications. FEATURES Energy saving Anti-glare reduces glare where end user has direct visual contact with the light source Shock and vibration resistant tempered glass Optional luminous intensity and colour temps available SELECTION GUIDE Dimensions (mm) Catalogue No. Watts Voltage Length Width Height Luminous flux (lm) Input Current (ma) Weight (kg) LEDA120SPT/Z1 120 AC LEDA150SPT/Z1 150 AC INSTALLATION ACCESSORIES Product Description Catalogue No. Bracket For ceiling mounting BR-F-O SBT-F-O Stanchion Bracket SBT2-F-O SBT-F-O Eyebolt For pendant mounting LO-F Pipe Connector PCR-F Bracket for ceiling mounting Stanchion bracket Guards GU-F 48 Hazardous Areas Eyebolt for pendant mounting Pipe Connector Guards
51 ALUMINIUM LED LOWBAY ZONE 1 & 2, 21 & 22 TECHNICAL DRAWINGS 426mm 187mm Ø410mm Top View Side view LIGHT DISTRIBUTION CURVE LED Lighting A B C D E F Colour Temp Candela Distribution Beam Angle Warm Natural Cool A B C D E C0-180º:120 C90-270º: PART NUMBER ORDER CONVENTION LEDA120SPT/Z1/ / Colour temp Distribution type Standard catalogue number F C0-180º:110 C90-270º: brenclosures.com.au Hazardous Areas 49
52 ALUMINIUM LED LINEAR LIGHT ZONES 1 & 2, 21 & 22 MATERIALS Body High impact resistant aluminium alloy Lamps 18W and 30W options Lamp source Osram LED Rated voltage V Surface finish High corrosion epoxy powdercoated orange INCLUSIONS Light Long-life energy saving LED Fixings CERTIFICATION IECEx CQM X PROTECTION Ex d IIB T6 Gb Ex tb IIIC T80ºC Db IP66 AMBIENT TEMPERATURE -40ºC ~ +55ºC Range: Arowana Series IP 66 OVERVIEW The explosion-proof LED linear lights are an energy saving light designed for use in hazardous and marine locations. The robust construction is designed to operate in salt water and corrosive environments. Suitable for use within chemical, petrochemical, dust and grain applications. FEATURES Energy saving Anti-glare reduces glare where end user has direct visual contact with the light source Shock and vibration resistant tempered glass Optional luminous intensity and colour temps available SELECTION GUIDE Dimensions (mm) Catalogue No. Watts Length Width Height Luminous flux (lm) Input Current (ma) Weight (kg) LEDA18BAR/Z1* LEDA30BAR/Z1* * For more information on candela distribution please see page 51. INSTALLATION ACCESSORIES Product Description Catalogue No. Bracket For ceiling mounting BR-A-O Pipe Clamp PCP-A Eyebolt For pendant mounting LO-A Guard GU-A Bracket for ceiling mounting Pipe Clamp 50 Hazardous Areas Eyebolt for pendant mounting Wire Guard
53 TECHNICAL DRAWINGS 480mm 180mm 62mm ALUMINIUM LED LINEAR LIGHT ZONES 1 & 2, 21 & 22 Front View Side View LIGHT DISTRIBUTION CURVE LED Lighting Colour Temp * Warm White 1 Natural White 2 Cool White 3 * References catalogue numbers on page 50. PART NUMBER ORDER CONVENTION LEDA18BAR/Z1/ Colour temp (eg. 1, 2 or 3) Standard catalogue number brenclosures.com.au Hazardous Areas 51
54 ALUMINIUM LED LOWBAY ZONES 1 & 2, 21 & 22 MATERIALS Body High impact resistant aluminium alloy Lamps 30W and 60W options Lamp source Osram LED Rated voltage V Surface finish High corrosion epoxy powdercoated orange INCLUSIONS Light Long-life energy saving LED Fixings Mount supplied seperately CERTIFICATION IECEx CQM x PROTECTION Ex d IIB T5/T6 Gb Ex t IIIC T95ºC/T80ºC Db IP66 AMBIENT TEMPERATURE -40ºC ~ +55ºC Range: Goldenfrog IP 66 OVERVIEW The explosion-proof LED lowbay are an energy saving light designed for use in hazardous and marine locations. The robust construction is designed to operate in salt water and corrosive environments. Suitable for use within chemical, petrochemical, dust and grain applications. FEATURES Energy saving Anti-glare reduces glare where end user has direct visual contact with the light source Shock and vibration resistant tempered glass Optional luminous intensity and colour temps available SELECTION GUIDE Dimensions (mm) Catalogue No. Watts Length Width Height Luminous flux (lm) Input Current (ma) Weight (kg) LEDA30SPT/Z LEDA60SPT/Z INSTALLATION ACCESSORIES Product Description Catalogue No. Brackets For ceiling mounting BR-A-O Stanchion bracket SBT-GF-O Eyebolt For pendant mounting LO-A Pipe clamp PCP-A Guard GU-GF Bracket for ceiling mounting Pipe Clamp 52 Hazardous Areas Eyebolt for pendant mounting Guards
55 ALUMINIUM LED LOWBAY ZONES 1 & 2, 21 & 22 TECHNICAL DRAWINGS 311mm 190mm Top View Side View LIGHT DISTRIBUTION CURVES A B C LED Lighting D E F Colour Temp Catalogue No. LEDA30SPT/Z1 LEDA60SPT/Z1 Candela Distribution Warm Natural Cool A B C D E F A B C D E F PART NUMBER ORDER CONVENTION LEDA30SPT/Z1/ / Colour temp Distribution type Standard catalogue number brenclosures.com.au Hazardous Areas 53
56 ALUMINIUM LED LOWBAY ZONES 1 & 2, 21 & 22 MATERIALS Body Aluminium alloy Transparent cover Toughened glass Lamp source Osram LED Surface finish Epoxy powdercoated grey INCLUSIONS Phoenix cage terminals Voltage range of AC V Lamp options 30W, 45W and 60W CERTIFICATION IECEx CQM x PROTECTION Ex de IIC DIP A21 TA For 'T Rating' refer to IECEx certificate AMBIENT TEMPERATURE -40ºC Ta +50ºC Range: CZ0873/1 (30W) CZ0874/1 (45W / 60W) IP 66 OVERVIEW The explosion-proof LED lowbay are an energy saving light designed for use in hazardous and marine locations. The robust construction is designed to operate in salt water and corrosive environments. Suitable for use within chemical, petrochemical, dust and grain applications. FEATURES Energy saving and long service life LED lamps Service life up to 50,000 hours Convenient mounting and ease of maintenance Multiple mounting options available SELECTION GUIDE Dimensions (mm) Catalogue No. Watts Length Width Height Mounting Weight (kg) LED030FLD/C/Z LED045FLD/C/Z Bracket 5.55 LED060FLD/C/Z LED030FLD/P9/Z LED045FLD/P9/Z º Pole 5.55 LED060FLD/P9/Z LED030FLD/P2/Z LED045FLD/P2/Z º Pole 5.55 LED060FLD/P2/Z LED030FLD/W/Z LED045FLD/W/Z Wall 5.55 LED060FLD/W/Z INSTALLATION ACCESSORIES Catalogue No. Product To suit 30W To suit 45W & 60W Ceiling bracket (set) D8722/1 D8722/1 Mounting bracket (set) D8701/1 D8701/2 Pendant mounting bracket (set) D8702/1 D8702/2 ¾" straight pipe (set) D732 Chain (set) D623 Lamp pole fence (set) D8725 Lamp pole flange (set) D8726 Bracket mount Pole 90º 54 Hazardous Areas Pole 25º Wall mount
57 ALUMINIUM LED LOWBAY ZONES 1 & 2, 21 & 22 TECHNICAL DRAWINGS A B Side View Front View bracket mount Front View pendant mount LED Lighting Front View mounting bracket Side Vew pole mount 90º Side Vew pole mount 25º LIGHT DISTRIBUTION CURVE W 45W 60W brenclosures.com.au Hazardous Areas 55
58 ALUMINIUM LED WELL GLASS ZONES 1 & 2, 21 & 22 MATERIALS Body Copper-free aluminium alloy Transparent cover Toughened glass Lamp source Long-life LED Rated voltage AC V, 50/60Hz Surface finish Epoxy powdercoated yellow INCLUSIONS Lamp options 20W, 30W, 50W, 70W, 100W and 120W Multiple mounting options CERTIFICATION IECEx CQM x PROTECTION Ex d IIC T6 (-40ºC Ta +40ºC) / T5 (-40ºC Ta +55ºC) Gb Ex t IIIC T80ºC (-40ºC Ta +40ºC) /T95ºC (-40ºC Ta +55ºC) Db IP66 AMBIENT TEMPERATURE -40ºC ~ +55ºC T5-40ºC ~ +40ºC T6 Range: BAD85 Series IP 66/67 OVERVIEW The explosion-proof LED well glass lights are an energy saving light designed for use in hazardous and marine locations. The robust construction is designed to operate in salt water and corrosive environments. Suitable for use within chemical, petrochemical, dust and grain applications. FEATURES Energy saving and long service life LED lamps Isolated LED lamp compartment Wind convection heat dissipation structure Three enclosure sizes SELECTION GUIDE Dimensions (mm) Catalogue No. Watts Height Width Mounting Weight (kg) LEDA020FLD/C/Z1 20W LEDA030FLD/C/Z1 30W LEDA050FLD/C/Z1 50W Ceiling LEDA070FLD/C/Z1 70W LEDA100FLD/C/Z1 100W LEDA120FLD/C/Z1 120W LEDA020FLD/H/Z1 20W LEDA030FLD/H/Z1 30W LEDA050FLD/H/Z1 50W Hook LEDA070FLD/H/Z1 70W LEDA100FLD/H/Z1 100W LEDA120FLD/H/Z1 120W LEDA020FLD/P/Z1 20W LEDA030FLD/P/Z1 30W LEDA050FLD/P/Z1 50W Pendant pole LEDA070FLD/P/Z1 70W LEDA100FLD/P/Z1 100W LEDA120FLD/P/Z1 120W LEDA020FLD/W/Z1 20W LEDA030FLD/W/Z1 30W LEDA050FLD/W/Z1 50W Wall LEDA070FLD/W/Z1 70W LEDA100FLD/W/Z1 100W LEDA120FLD/W/Z1 120W LEDA020FLD/S/Z1 20W LEDA030FLD/S/Z1 30W LEDA050FLD/S/Z1 50W Pole LEDA070FLD/S/Z1 70W LEDA100FLD/S/Z1 100W LEDA120FLD/S/Z1 120W Hazardous Areas
59 ALUMINIUM LED WELL GLASS ZONES 1 & 2, 21 & 22 TECHNICAL DRAWINGS 208mm 350mm 385mm 210mm 255m 295mm Front View 20W &30W Front View 50W &70W Front View 100W &120W LED Lighting LIGHT DISTRIBUTION CURVE 0 90º 0 90º 0 90º º º 60º º 30º 0º 30º 0º 30º 20W & 30W 50W & 70W 100W & 120W brenclosures.com.au Hazardous Areas 57
60 ALUMINIUM WELL GLASS LIGHT 400W ZONES 1 & 2 MATERIALS Body Aluminium alloy Diffuser Toughened glass Lamp sources High Pressure Sodium, Metal Halide or Mercury Vapour Lamp holder E40 Rated voltage AC 240V, 50Hz Ballast Conventional Wire guard Zinc coated Surface finish Epoxy powdercoated yellow or grey INCLUSIONS Stainless steel fixings Integral control gear Wire guard Optional external dome or angle reflector available CERTIFICATION IECEx CQM PROTECTION Ex d IIC T3 AMBIENT TEMPERATURE -20ºC ~ +55ºC IP 66 OVERVIEW The 400W flameproof well glass light fittings are manufactured from aluminium with a toughened glass diffuser. They are suitable for use in chemical and petrochemical applications. FEATURES Integral control gear Stainless steel fixings Multiple mounting methods SELECTION GUIDE Dimensions (mm) Catalogue No. Length Height Total Height Lamp Source Mounting Weight (kg) WGA400MH/H Hook WGA400MH/P Pendant WGA400MH/B Metal Halide (MH) Wall WGA400MH/C Ceiling WGA400MH/S Stanchion / Pole WGA400MV/H Hook WGA400MV/P Pendant WGA400MV/B Mercury Vapour (MV) Wall WGA400MV/C Ceiling WGA400MV/S Stanchion / Pole WGA400HS/H Hook WGA400HS/P Pendant WGA400HS/B High Pressure Sodium (HS) Wall WGA400HS/C Ceiling WGA400HS/S Stanchion / Pole INSTALLATION ACCESSORIES Product Description Catalogue No. Angle RA400 External Reflectors Dome RD400 External Reflector angled External Reflector dome 58 Hazardous Areas
61 ALUMINIUM WELL GLASS LIGHT 400W ZONES 1 & TECHNICAL DRAWINGS 185 Ø Front View Ø 469 Front View with Dome Reflector Front View with Angled Reflector Mounting Options Ø Well Glass Lighting º H: Hook Mount P: Pendant Mount B: Wall Mount C: Ceiling Mount S: Pole Mount TECHNICAL DRAWINGS Luminous intensity distribution = cd/1000lm Based on 400W metal halide lamp for High Pressure Sodium multiply x 1.37 for Mercury lamp multiply x 0.6 brenclosures.com.au Hazardous Areas 59
62 ALUMINIUM WELL GLASS LIGHT ZONES 1 & 2 MATERIALS Body Aluminium alloy Diffuser Toughened glass Lamp sources High Pressure Sodium, Metal Halide or Mercury Vapour Lamp holder E40 Rated voltage AC 240V, 50Hz Wire guard Zinc coated Surface finish Epoxy powdercoated yellow or grey INCLUSIONS Stainless steel fixings Integral control gear Optional external dome or angle reflector available CERTIFICATION ECEx CQM (150W 250W) IECEx CQM x (400W only) PROTECTION Ex d e IIC T3 (150W 250W) Ex d e IIC T3 Gb (400W only AMBIENT TEMPERATURE -20ºC ~ +55ºC (150W 250W) -20ºC Ta +55ºC (400W only IP 65 OVERVIEW The aluminium flameproof well glass light fittings are manufactured from aluminium with a toughened glass diffuser. They are suitable for use in chemical and petrochemical applications. FEATURES Integral control gear Stainless steel fixings Multiple mounting method Ex d e configuration for ease of termination SELECTION GUIDE Dimensions (mm) Width Depth Height Total Height Catalogue No. Watts (A) (B) (C) (D) Lamp Source Weight (kg) WGA175MH/T WGA250MH/T Metal Halide WGA400MH/T WGA175MV/T WGA250MV/T Mercury Vapour WGA400MV/T WGA150HS/T WGA250HS/T High Pressure Sodium WGA400HS/T INSTALLATION ACCESSORIES Product Description Catalogue No. To suit 400W light RA400/T External Reflectors angled To suit 250W light RA250/T To suit 175W light RA175/T To suit 400W light RD400/T External reflectors dome To suit 250W light RD250/T To suit 175W light RD175/T External Reflector angled External Reflector dome 60 Hazardous Areas
63 ALUMINIUM WELL GLASS LIGHT ZONES 1 & 2 TECHNICAL DRAWINGS D C 20 15º 13 A B E Front View Side View Front View Dome Reflector Side View Angled Reflector Mounting Bracket Well Glass Lighting LIGHT DISTRIBUTION CURVES WGA 250 Series (includes 150W, 175W and 250W) 180º 150º 180º 150º 180º 135º 0 90º º º º º º 30º 400 0º 30º 240 0º 30º WGA 400W 180º 150º 180º 150º 180º 135º 0 90º 0 90º º º 50º º º 30º 0º 30º 0º 30º brenclosures.com.au Hazardous Areas 61
64 ALUMINIUM 150W-400W FLOODLIGHT ZONES 1 & 2 MATERIALS Body Aluminium alloy Diffuser Toughened glass Lamp sources High Pressure Sodium, Metal Halide or Mercury Vapour Lamp holder E40 Rated voltage AC 240V, 50Hz Wire guard Zinc coated Surface finish Epoxy powdercoated yellow or grey INCLUSIONS Stainless steel fixings Lamp holder W 2 x M25, 1 plugged clearance hole 400W 2 x M20, 1 plugged W available in portable or fixed mounting 400W available in fixed mounting only Ex e termination box for ease of cabling CERTIFICATION ECEx CQM (150W 250W) IECEx CQM (400W only)) PROTECTION Ex de IIB T3 Gb (150W 250W) Ex de IIB T3 (400W only) IP 65 OVERVIEW Suitable for use in Zone 1 & 2 applications, the robust construction allows the fixture to be utilised in the most arduous of environments. Available in fixed or portable mounting. FEATURES Seperate Ex e rated termination compartment Portable option available with plug and cable fitted on request up to 20 metres W available in either portable or fixed mounting 400W available in fixed mounting only SELECTION GUIDE Dimensions (mm) Entries^ Width Height Depth Catalogue No. Watts (A) (B) (C) Lamp Source Mounting Number Type Weight (kg) FLDA175MH/M Portable 1 x M25 Clearance 13.0 FLDA250MH/M Portable 2 x M20 Clearance 13.0 FLDA175MH/T Metal Hallide (MH) Fixed 1 x M25 Clearance 13.0 FLDA250MH/T Fixed 2 x M20 Clearance 13.0 FLDA400MH/T Fixed 2 x M25 Threaded 28.0 FLDA150HS/M Portable 1 x M25 Clearance 13.0 FLDA250HS/M Portable 1 x M25 Clearance 13.0 FLDA150HS/T High Pressure Sodium (HS) Fixed 1 x M25 Clearance 13.0 FLDA250HS/T Fixed 1 x M25 Clearance 13.0 FLDA400HS/T Fixed 2 x M25 Threaded 28.0 Please Note: 175W option not available with High Pressure Sodium lamp source ^ All entries are 2 entries, 1 plugged 62 Hazardous Areas
65 ALUMINIUM 150W-400W FLOODLIGHT ZONES 1 & 2 TECHNICAL DRAWINGS A: 250 Series Portable mounting option B: 250 Series Fixed mounting option C C B B 3 x Ø12 A A Front View Side View Front View Side View Fixing Points C: 400 Series Fixed mounting only C B 40 Ø165 4 x Ø13 Floodlighting A Front View Side View Fixing Points LIGHT DISTRIBUTION CURVE brenclosures.com.au Hazardous Areas 63
66 ALUMINIUM WELL GLASS FLOODLIGHT ZONE 2, 21 & 22 MATERIALS Body Copper-free aluminium alloy Transparent cover Toughened glass, stands 4J impact Fixings 316 stainless steel Lamp holder E27 Surface finish Powdercoated yellow INCLUSIONS 1 x M25 x 1.5mm cable entries Fixings CERTIFICATION IECEx CQM x (175W & 250W) IECEx CQM x (400W) PROTECTION Ex nr IIC T3 Gc Ex t IIIC T190ºC Db IP65 AMBIENT TEMPERATURE -60ºC ~ +55ºC Range: BnD81 Series IP 66 OVERVIEW Suitable for use in zone 2 applications and available in two enclosure sizes with various lamp types to suit the application. The explosion proof well glass floodlight has an aluminium body and toughened glass cover to withstand the most challenging conditions. FEATURES Integral control gear for easy installation and maintenance Dome reflector available SELECTION GUIDE Catalogue No. Dimensions (mm) Metal Hallide High Pressure Sodium High Pressure Mercury Watts Width Height Mounting Type WGA175/MH/C/Z2 WGA150/HS/C/Z2 175W WGA250/MH/C/Z2 WGA250/HS/C/Z2 WGA250/MV/C/Z2 250W Ceiling WGA400/MH/C/Z2 WGA400/HS/C/Z2 WGA400/MV/C/Z2 400W WGA175/MH/W/Z2 WGA150/HS/W/Z2 150W WGA250/MH/W/Z2 WGA250/HS/W/Z2 WGA250/MV/W/Z2 250W Wall WGA400/MH/W/Z2 WGA400/HS/W/Z2 WGA400/MV/W/Z2 400W WGA175/MH/P25/Z2 WGA150/HS/P25/Z2 150W WGA250/MH/P25/Z2 WGA250/HS/P25/Z2 WGA250/MV/P25/Z2 250W Pole 25º WGA400/MH/P25/Z2 WGA400/HS/P25/Z2 WGA400/MV/P25/Z2 400W WGA175/MH/P/Z2 WGA150/HS/P/Z2 150W WGA250/MH/P/Z2 WGA250/HS/P/Z2 WGA250/MV/P/Z2 250W Pendant Pole WGA400/MH/P/Z2 WGA400/HS/P/Z2 WGA400/MV/P/Z2 400W Hazardous Areas
67 ALUMINIUM WELL GLASS FLOODLIGHT ZONE 2, 21 & 22 TECHNICAL DRAWINGS Height LIGHT DISTRIBUTION CURVE Floodlighting Width Width Height Height Width Height Front View ceiling mount Front View wall mount Front View pendant pole Front View 25º pole 0 90º º º º º 60º º 30º 0º 30º 0º 30º 150W 250W 400W brenclosures.com.au Hazardous Areas 65
68 ALUMINIUM FLOODLIGHT ZONE 1 & 2, 21 & 22 MATERIALS Body Copper-free aluminium alloy Cover Toughened glass, stands 4J impact Internal reflector High purity aluminium Fixings 316 stainless steel Lamp 400W Lamp holder E40 Surface finish Powdercoated white INCLUSIONS Fixings CERTIFICATION IECEx CQM x PROTECTION Ex nr IIC T3 Gc Ex nr IIC T252º Gc Ex t IIC T190ºC Db IP65 Ex t IIIC T252ºC Db IP65 AMBIENT TEMPERATURE -60ºC ~ +55ºC Range: BnT81 Series IP 66 OVERVIEW Suitable for use in zone 2 applications and available in two enclosure sizes with various lamp types to suit the application. The explosion proof floodlight has an aluminium body and toughened glass cover to withstand the most challenging conditions.. FEATURES Rapid starting and stable performance All exposed fasteners are stainless steel SELECTION GUIDE Dimensions (mm) Catalogue No. Watts Lamp Source Height Width Depth Weight (kg) FLDA150HS/Z FLDA250HS/Z2 250 High Pressure Sodium FLDA400HS/Z FLDA150MH/Z FLDA250MH/Z2 250 Metal Hallide FLDA400MH/Z TECHNICAL DRAWINGS 572mm 165mm 418mm Front View Side View 66 Hazardous Areas
69 ALUMINIUM TANK INSPECTION VESSEL LIGHT ZONES 1 & 2 MATERIALS Body Aluminium alloy Diffuser Toughened glass Lamp sources Halogen Tungsten Lamp wattage 35W Rated voltage 240V, 50Hz Surface finish Epoxy powdercoated yellow INCLUSIONS Mounting arm or ceiling bracket 1 x M20, cable gland entries CERTIFICATION IECEx LCI PROTECTION Ex d IIB T3 IP65 AMBIENT TEMPERATURE -20ºC ~ +55ºC Range: BAK51 Series IP 65 OVERVIEW The flameproof tank inspection vessel light fittings are manufactured from aluminim alloy with a toughened glass diffuser and are suitable for use in chemical and petrochemical applications. FEATURES Specially designed reflector SELECTION GUIDE Dimensions (mm) Catalogue No. Watts Width Height Lamp Source Mounting Type WGV035TH/A Arm Halogen Tungsten WGV035TH/B Ceiling TECHNICAL DRAWINGS 204mm 205.5mm Floodlighting 126mm 166.5mm Side View Mounting Option (/A) Front View Mounting Option (/B) brenclosures.com.au Hazardous Areas 67
70 300W HALOGEN FLOODLIGHT ZONE 2 MATERIALS Body 316 stainless steel, deep drawn Glass front Heat and impact resistant Gasket Silicone rubber Internal reflector High reflectance aluminium Fixings 316 stainless steel Lamp holder R7S Rated voltage 240V, 50Hz Surface finish Epoxy powdercoated white INCLUSIONS 300W Halogen lamp 1 x M20 cable gland entry Stainless steel trunnion mounting arm Rubber mount pad for high vibration areas CERTIFICATION IECEx KGS x PROTECTION Ex n R II T2 IP67 AMBIENT TEMPERATURE -20ºC ~ +55ºC Range: PF-HnR Series IP 66/67 OVERVIEW The 300W halogen floodlight is manufactured from 316 stainless steel with heat and impact resistant glass front. The powdercoated stainless steel construction and IP66/67 protection rating allows it to be used in the most arduous environments. FEATURES 316 stainless steel construction Stainless steel trunnion mounting arm Vertical adjustment (up 75º, down 45º) SELECTION GUIDE Dimensions (mm) Catalogue No. Lamp Length Width Height Weight (kg) FLDS300TH/T/Z2 300W Hazardous Areas
71 300W HALOGEN FLOODLIGHT ZONE 2 TECHNICAL DRAWINGS 360mm 360mm 2 x ø14 holes mm 137mm M20 cable gland entry Front View Side View Fixing Dimensions LIGHT DISTRIBUTION CURVE Floodlighting 120º º 90º 90 90º 60º º º 0º 30º brenclosures.com.au Hazardous Areas 69
72 ALUMINIUM AUDIO & VISUAL CAUTION LIGHT ZONES 1 & 2 MATERIALS Body Copper-free aluminium alloy Transparent cover Toughened glass, impact resistant Lamps 2W LED Rated voltage AC V, 50/60Hz Surface finish Epoxy powdercoated yellow / grey INCLUSIONS Lamp colour Red, blue, yellow and green Mounting accessories Flash frequency 150 times per minute Sound intensity dB Pendant type supplied with explosion-proof junction box Horizontal type 1 x M25 entries Pendant type 2 x M25 entries CERTIFICATION IECEx CQM PROTECTION Ex d ib IIC T6 Gb AMBIENT TEMPERATURE -20ºC ~ +55ºC Range: BBJ Series IP 65 OVERVIEW The explosion proof caution lights are an energy saving light designed for use in chemical, petrochemical, grain, dust and other hazardous area applications. FEATURES Energy saving Ultra bright LED lamp Low power consumption and long service life up to 30,000 hours Pendant and horizontal mounting options SELECTION GUIDE Dimensions (mm) Catalogue No. Watts Width Height Mounting Lamp Colour Weight (kg) LEDA2AVCL/C/Z1/R 2W Red 3.0 LEDA2AVCL/C/Z1/B 2W Blue 3.0 Ceiling LEDA2AVCL/C/Z1/Y 2W Yellow 3.0 LEDA2AVCL/C/Z1/G 2W Green 3.0 LEDA2AVCL/H/Z1/R 2W Red 4.45 LEDA2AVCL/H/Z1/B 2W Blue 4.45 Horizontal LEDA2AVCL/H/Z1/Y 2W Yellow 4.45 LEDA2AVCL/H/Z1/G 2W Green 4.45 TECHNICAL DRAWINGS 205mm 195mm 70 Hazardous Areas
73 ALUMINIUM VISUAL CAUTION LIGHT ZONES 1 & 2, 21 & 22 MATERIALS Body Copper-free aluminium alloy Transparent cover Toughened glass, impact resistant Lamps 3W LED Lamp colour Red, blue, yellow and green Rated voltage AC V, 50/60Hz Surface finish Epoxy powdercoated yellow / grey INCLUSIONS Lamp colour Red, blue, yellow and green Mounting accessories Flash frequency 150 times per minute Pendant type supplied with explosion-proof junction box Horizontal type 1 x M25 entries Pendant type 2 x M25 entries CERTIFICATION IECEx CQM x PROTECTION Ex d IIC T6 Gb Ex t IIIC T80ºC Db IP66 AMBIENT TEMPERATURE -40ºC ~ +55ºC Range: BJD81 Series IP 66/67 OVERVIEW The explosion proof caution lights are an energy saving light designed for use in chemical, petrochemical, grain, dust and other hazardous area applications. FEATURES Energy saving Ultra bright LED lamp Low power consumption and long service life Pendant and horizontal mounting options SELECTION GUIDE Dimensions (mm) Catalogue No. Width Height Mounting Lamp Colour Weight (kg) LEDA03VCL/C/Z1/R Red 2.5 LEDA03VCL/C/Z1/B Blue 2.5 Ceiling LEDA03VCL/C/Z1/Y Yellow 2.5 LEDA03VCL/C/Z1/G Green 2.5 LEDA03VCL/H/Z1/R Red 4.4 LEDA03VCL/H/Z1/B Blue 4.4 Horizontal LEDA03VCL/H/Z1/Y Yellow 4.4 LEDA03VCL/H/Z1/G Green 4.4 TECHNICAL DRAWINGS 230mm Caution Lighting 146mm brenclosures.com.au Hazardous Areas 71
74 ALUMINIUM LOCAL VISUAL CAUTION LIGHT ZONES 1 & 2, 21 & 22 MATERIALS Body Copper-free aluminium alloy Transparent cover Toughened glass, impact resistant Lamps 10W LED Rated voltage AC V, 50/60Hz Surface finish Epoxy powdercoated yellow / grey INCLUSIONS Lamp colour Red Luminous intensity >200cd Flash frequency 1 second 4 x M25 cable entries (3 plugged) CERTIFICATION IECEx CQM x PROTECTION Ex de IIC T6 Gb Ex tb IIIC T80ºC Db IP66 AMBIENT TEMPERATURE -20ºC ~ +55ºC Range: BSZD81 Series IP 65 OVERVIEW The explosion proof caution lights are an energy saving light designed for use in chemical, petrochemical, grain, dust and other hazardous area applications. SELECTION GUIDE FEATURES Energy saving Ultra bright LED lamp Low power consumption and long service life up to 55,000 hours Integrated control chip with various circuit protection Synchronis function of light fitting via signal lines Dimensions (mm) Catalogue No. Watts Width Height Mounting Weight (kg) LEDA10VCL/C/Z1 10W Ceiling 10.0 TECHNICAL DRAWINGS 250mm Lamp 1 Lamp 2 Lamp mm L N PE Power Supply V AC 50/60Hz 72 Hazardous Areas
75 MATERIALS Body Copper-free aluminium alloy Transparent cover Toughened glass, impact resistant Lamps 40W LED Rated voltage AC V, 50/60Hz Surface finish Epoxy powdercoated yellow / grey ALUMINIUM LOCAL VISUAL CAUTION LIGHT ZONES 1 & 2, 21 & 22 INCLUSIONS Lamp colour Red Luminous intensity >2000cd Flash frequency times per minute 4 x M25 entries (3 plugged) CERTIFICATION IECEx CQM x PROTECTION Ex de IIC T6 Gb Ex tb IIIC T80ºC Db IP66 AMBIENT TEMPERATURE -40ºC ~ +55ºC Range: BSZD81-C Series IP 65 OVERVIEW The explosion proof caution lights are an energy saving light designed for use in chemical, petrochemical, grain, dust and other hazardous area applications. SELECTION GUIDE Dimensions (mm) Catalogue No. Watts Width Height Mounting Weight (kg) LEDA40VCL/C/Z Ceiling 13.8 FEATURES Energy saving Ultra bright LED lamp Low power consumption and long service life up to 30,000 hours Integrated control chip with various circuit protection Synchronis function of light fittings via signal lines Caution Lighting TECHNICAL DRAWINGS 308mm Lamp 1 Lamp 2 Lamp mm L N PE Power Supply V AC 50/60Hz brenclosures.com.au Hazardous Areas 73
76 ALUMINIUM ANNULAR COMPACT FLUORESCENT ZONES 1 & 2 MATERIALS Body Aluminium alloy Wire guard Zinc coated white Diffuser High impact glass Reflector Pure aluminium Ballast Conventional Lamp holder GR-10q Rated voltage AC240V, 50Hz Surface finish Powdercoated yellow or grey INCLUSIONS Light fitting 2 x M20 cable gland entries (1 plugged) Zinc coated wire guard Lamps single or twin 21W supplied CERTIFICATION IECEx CQM PROTECTION Ex d IIB T5 AMBIENT TEMPERATURE -20ºC Tamb +55ºC IP 65 OVERVIEW The flameproof annular fluorescent light fittings are manufactured from aluminium alloy and are suitable for use in chemical and petrochemical applications. FEATURES Toughened glass cover, anti-impact and high light transmission PL compact lamps SELECTION GUIDE Dimensions (mm) Catalogue No. Watts No. of Lamps Length Width Height Diameter Weight (kg) FLUA21X1/C 21W FLUA21X2/C 21W Hazardous Areas
77 ALUMINIUM ANNULAR COMPACT FLUORESCENT ZONES 1 & 2 TECHNICAL DRAWINGS 245mm 160mm D 270mm 4xø10 Front View Top View LIGHT DISTRIBUTION CURVE 0 90º 0 90º º 60º º 30º 0º 30º Fluroescent Lighting 21W x 1 21W x 2 21W x 2 brenclosures.com.au Hazardous Areas 75
78 ALUMINIUM FLUORESCENT ZONES 1 & 2 MATERIALS Body Die cast aluminium Ballast Electronic Lamp holder T8 Bi Pin Rated voltage 240V, 50Hz Surface finish Epoxy powdercoated yellow or grey INCLUSIONS Lamps Single or twin 18W or 36W lamps 2 x M20 entries Anti-vibration rubber mounts CERTIFICATION IECEx KGS x (20W) IECEx KGS x (40W)) PROTECTION Ex d IIC T6 or T5 IP67 AMBIENT TEMPERATURE -20ºC ~ +50ºC Range: FX Series IP 66/67 OVERVIEW The flameproof fluorescent light fittings are manufactured from aluminium and are suitable for use in Zone 1 & 2 applications. The aluminium body allows the fixture to be used in the most arduous of environments. FEATURES Electronic ballast Removable chassis for easy lamp replacement Anti-vibration rubber mounts Immersible to 1 metre Emergency option available on request SELECTION GUIDE Dimensions (mm) Length Width Height Fixings Catalogue No. Watts No. of Lamps (A) (B) (C) (D) Weight (kg) FLUA018X1/C 18W FLUA018X2/C 18W FLUA036X1/C 36W FLUA036X2/C 36W Hazardous Areas
79 ALUMINIUM FLUORESCENT ZONES 1 & 2 TECHNICAL DRAWINGS C B D A Front View Top View LIGHT DISTRIBUTION CURVE 120º º 90º 90º º º Fluroescent Lighting 30º 0º 30º brenclosures.com.au Hazardous Areas 77
80 STAINLESS STEEL FLUORESCENT ZONES 1 & 2 MATERIALS Body 316 stainless steel Diffuser Polycarbonate Latch & fixings 316 stainless steel Lamps 2 x 18W or 36W Lamp holder T8 Bi Pin Body surface finish Epoxy powdercoated white INCLUSIONS Lamps Stainless steel retaining clips and mounting feet CERTIFICATION IECEx KGS x (18W) IECEx KGS x (36W)) PROTECTION Ex d emb IIC T4 Gb Ex d interlock switch AMBIENT TEMPERATURE -25ºC ~ +50ºC Range: FL-220EDG (18W) FL-240EDG (36W IP 66/67 OVERVIEW Suitable for Zone 1 & 2 applications. The stainless steel body allows the fixture to be utilised in the most arduous environments including metalliferous mining, chemical, petrochemical and industrial construction sites. FEATURES 316 stainless steel body and fixings Centre allen key locking arrangement 2 x M20 entries Emergency option available on request SELECTION GUIDE Dimensions (mm) Length Width Height Catalogue No. Watts No. of Lamps (A) (B) (C) Weight (kg) FLUS018X2/C 18W FLUS036X2/C 36W Hazardous Areas
81 STAINLESS STEEL FLUORESCENT ZONES 1 & 2 C B TECHNICAL DRAWINGS 188mm A 500mm 4 x ø10 holes Front View Top View LIGHT DISTRIBUTION CURVE 120º º 90º 90º º º Fluroescent Lighting º 0º 30º brenclosures.com.au Hazardous Areas 79
82 NON-METALLIC FLUORESCENT EMERGENCY & NON-EMERGENCY ZONES 1 & 2, 21 & 22 MATERIALS Body SMC Diffuser Polycarbonate Terminals 3 x 1.5 4mm Brass gland plate Lamps single or twin 18W or 36W lamp Lamp holder T8 Bi Pin Rated voltage 250V, 50Hz INCLUSIONS Lamps T8 18W or 36W 2 x M25 entries each end (2 plugged) Ceiling mount brackets as standard EOL on ballast CERTIFICATION IECEx CQM (standard) IECEx CQM (emergency) PROTECTION Ex deq IIC T4 Gb Ex td A21 IP66 T80ºC AMBIENT TEMPERATURE -20ºC Ta +55ºC IP 66 OVERVIEW The non-metallic fluorescent lights consist of an SMC body with a polycarbonate diffuser. The light fitting is available in both non-emergency and emergency options. The emergency light fitting automatically recharges during normal operations and lamps turn on when there is a power loss FEATURES EOL (end of life) on ballast Key operated central mechanical interlocking device Ex d switch for automatic power off when cover is unlocked Fault, charge and discharge signal for emergency models Internal catches clamp on both sides of diffuser Installation accessories available SELECTION GUIDE Dimensions (mm) Product Standard Emergency Catalogue No. Watts No. of Lamps Length (A) Width (B) Height (C) Mounting Weight (kg) FLUG018X1/CA1 18W Ceiling 6.7 FLUG018X2/CA1 18W Ceiling 6.9 FLUG036X1/CA1 36W Ceiling 11.3 FLUG036X2/CA1 36W Ceiling 11.4 FLUG018X2/CA1E 18W Ceiling 8.7 FLUG036X2/CA1E 36W Ceiling Hazardous Areas
83 NON-METALLIC FLUORESCENT EMERGENCY & NON-EMERGENCY ZONES 1 & 2, 21 & 22 TECHNICAL DRAWINGS A 90 B C 450mm Front View Top View Side View LIGHT DISTRIBUTION CURVE 0 90º 0 90º º 60º Fluroescent Lighting º 30º 0º 30º 18W x 2 36W x 2 brenclosures.com.au Hazardous Areas 81
84 NON-METALLIC FLUORESCENT EMERGENCY & NON-EMERGENCY ZONES 1 & 2, 21 & 22 MATERIALS Body SMC Diffuser Polycarbonate Lamps 2 x 14W, 18W, 28W and 36W Lamp holder T8 for 18W & 36W; T5 for 14W & 28W Rated voltage V INCLUSIONS EOL (End of Life) on ballast Dust cover on key lock Ceiling mount brackets CERTIFICATION IECEx CQM PROTECTION Ex deqmb IIC T4 Gb Ex td A21 T80ºC AMBIENT TEMPERATURE -20ºC ~ +40ºC Range: CZ0865/6 IP 66 OVERVIEW The non-metallic fluorescent lights consist of an SMC body with a polycarbonate diffuser. The light fitting is available in both non-emergency and emergency options. The emergency light fitting automatically recharges during normal operations and lamps turn on when there is a power loss FEATURES EOL (end of life) on ballast Central mechanical interlocking device Ex d switch for automatic power off when cover is unlocked Fault, charge and discharge signal for emergency models 1 x M25 and 2 x M25 entries at opposite ends T5 or T8 lamp options Internal brass plates SELECTION GUIDE Dimensions (mm) Length Width Height Fixings Catalogue No. Type Watts No. of Lamps (A) (B) (C) (D) Mounting Weight (kg) Lamp Holder FLUG014X2/C 14W Ceiling 5.0 T5 FLUG018X2/C 18W Ceiling 5.0 T8 Non-emergency FLUG028X2/C 28W Ceiling 7.9 T5 FLUG036X2/C 36W Ceiling 7.9 T8 FLUG014X2/CE 14W Ceiling 6.8 T5 FLUG018X2/CE 18W Ceiling 6.8 T8 Emergency FLUG028X2/CE 28W Ceiling 9.9 T5 FLUG036X2/CE 36W Ceiling 9.9 T8 INSTALLATION ACCESSORIES Product Size Catalogue No. Pipe clamps galvanised steel 42mm 45mm 47mm 50mm 59mm 62mm J200 J300 J Hazardous Areas
85 NON-METALLIC FLUORESCENT EMERGENCY & NON-EMERGENCY ZONES 1 & 2, 21 & 22 TECHNICAL DRAWINGS C 90 D A B Front View Side View LIGHT DISTRIBUTION CURVE B A A B B A A B 45 Fluroescent Lighting 2 x 18W 2 x 36W B 90 B 90 A 0 A 0 A 0 A 0 B 90 B 90 brenclosures.com.au Hazardous Areas 83
86 ALUMINIUM FLUORESCENT & LED LIGHT ZONES 1 & 2, 21 & 22 MATERIALS Body Copper-free aluminium alloy Glass tube Toughened glass Ballast Electronic Rated voltage AC V, 50/60H Surface finish Powdercoated yellow INCLUSIONS Fluorescent lamp options single or twin 18W, 36W or 58W LED lamp options single or twin 9W and 18W CERTIFICATION IECEx CQM x (Fluorescent option) IECEx CQM (LED option) PROTECTION Ex d IIC T6 Gb Ex t IIIC T80ºC Db IP66 AMBIENT TEMPERATURE -20ºC Ta +55ºC (Fluorescent) -40ºC ~ +55ºC (LED) Range: BAY-51 Series IP 66 OVERVIEW Suitable for use in zone 1 & 2 and zone 21 & 22 applications and available in both LED and fluorescent lamp types. The aluminium body and toughened glass diffuser will withstand the most demanding conditions. FEATURES End of lamp life rectification effect protection Single or dual lamp options Available with fluorescent or LED lamp source options SELECTION GUIDE Dimensions (mm) Length Width Catalogue No. Watts Lamp Type (A) (B) Mounting Weight (kg) LEDA009X1/C/Z1 9W LEDA009X2/C/Z1 9W LED Ceiling LEDA018X1/C/Z1 18W LEDA018X2/C/Z1 18W FLUA018X1/C/Z1 18W FLUA036X1/C/Z1 36W FLUA058X1/C/Z1 58W Fluorescent Ceiling FLUA018X2/C/Z1 18W FLUA036X2/C/Z1 36W FLUA058X2/C/Z1 58W Hazardous Areas
87 A A ALUMINIUM FLUORESCENT & LED LIGHT ZONES 1 & 2, 21 & 22 TECHNICAL DRAWINGS B B Side View Single lamp Side View Twin lamp LIGHT DISTRIBUTION CURVE LED Type 0 90º 0 90º 0 90º 0 90º º º 80 60º 80 60º º 30º 0º 30º 0º 30º 0º 30º 9W x 1 9W x 2 18W x 1 18W x 2 Fluorescent Type Fluroescent & LED Lighting º 90º 0 90º 0 90º 0 90º 90º º 80 60º 80 60º 80 60º 80 60º 80 60º º 30º 0º 30º 0º 30º 0º 30º 0º 30º 0º 30º 18W x 1 18W x 2 36W x 1 36W x 2 58W x 1 58W x 2 brenclosures.com.au Hazardous Areas 85
88 NON-METALLIC FLUORESCENT & LED EMERGENCY & NON-EMERGENCY ZONES 2, 21 & 22 MATERIALS Body Glass fibre reinforced polyester Diffuser Polycarbonate Fluorescent lamp twin 14W, 18W, 28W & 36W options LED lamp twin 19W standard in 36W body Lamp holder T8 or T5, G13 Rated voltage AC V, 50/60Hz on request INCLUSIONS EOL (End of Life) on ballast Dust cover on key lock Ceiling mount brackets Lamps CERTIFICATION IECEx CQM PROTECTION Ex na IIC T4 Gc/ Ex t IIIC T80ºC Db IP66 Ex mb na IIC T4 Gc/ Ex t IIIC T80ºC Db IP66 Ex d na IIC T4 Gc/ Ex t IIIC T80ºC Db IP66 Ex d mb na IIC T4 Gc/ Ex t IIIC T80ºC Db IP66 AMBIENT TEMPERATURE -25ºC ~ +50ºC Range: CZ087 Series IP 66 OVERVIEW The polyester central locking fluorescent and LED light fittings are manufactured from glass reinforced polyester and anti-ultraviolet polycarbonate. These light fittings are available with fluorescent or LED lamps. The material provides protection from various chemical matters in factories because of their high stability and mechanical strength and can prevent corrosion from occurring. FEATURES Robust construction Standard ceiling mount Anti-vibration lamp holders Mechanical interlocking device Explosion-proof distance switch for automatic power off Nicket plated brass and stainless steel cable gland options Through wiring SELECTION GUIDE Dimensions (mm) Length Width Height Fixings Catalogue No. Type Watts No. of Lamps (A) (B) (C) (D) Mounting Weight (kg) Lamp Holder FLUG014X2/C/Z T5 FLUG018X2/C/Z T8 Fluorescent Ceiling FLUG028X2/C/Z T5 FLUG036X2/C/Z T8 LED010X2/C/Z T5 Special LED Ceiling LED019X2/C/Z T8 Special 86 Hazardous Areas
89 NON-METALLIC FLUORESCENT & LED EMERGENCY & NON-EMERGENCY ZONES 2, 21 & 22 TECHNICAL DRAWINGS C D A B Front View Side View LIGHT DISTRIBUTION CURVE LED Type -90º 0 90º º 90º º º -60º º º 0º 30º º 0º 30º 10W x 2 19W x 2 Fluorescent Type -90º 0 90º º º º 0 90º º º 160 Fluroescent & LED Lighting º 0º 30º º 0º 30º 14W x 2 18W x 2-90º 0 90º º 0 90º º º -60º º º 0º 30º º 0º 30º 28W x 2 36W x 2 brenclosures.com.au Hazardous Areas 87
90 NON-METALLIC FLUORESCENT & LED LIGHT ZONE 2, 21 & 22 MATERIALS Body Polycarbonate Ballast Electronic Exposed fasteners Stainless steel Rated voltage V AC 50/60Hz INCLUSIONS Fluorescent lamp options 1 or 2 18W, 36W or 58W LED lamp options 1 or 2 9W and 18W 2 x M20 x 1.5mm cable glands Fixings CERTIFICATION IECEx CQM x PROTECTION Ex na IIC T4 Gc Ex t IIIC T80ºC Db IP66 AMBIENT TEMPERATURE -60ºC ~ +55ºC Range: BnY81 Series IP 66 OVERVIEW Suitable for use in zone 2 and zone 21 & 22 applications and available in both LED and fluorescent lamp types. The non metallic polycarbonate body is corrosion proof and impact resistant and the polycarbonate diffuser will withstand the most demanding conditions. FEATURES Dual tube light available with emergency function Fluroescent and LED options available Stainless steel diffuser clips Internal brass gland plate Installation accessories available SELECTION GUIDE Dimensions (mm) Catalogue No. Lamp Type Watts No. of Lamps Length (A) Width (B) Height (C) Fixings (D) FLUP018X1/C/Z2 18W FLUP018X2/C/Z2 18W FLUP036X1/C/Z2 36W Fluorescent FLUP036X2/C/Z2 36W FLUP058X1/C/Z2 58W FLUP058X2/C/Z2 58W LEDP009X1/C/Z2 9W LEDP009X2/C/Z2 9W LEDP018X1/C/Z2 18W LED LEDP018X2/C/Z2 18W LEDP025X1/C/Z2 25W LEDP025X2/C/Z2 25W Hazardous Areas
91 NON-METALLIC & LED FLUORESCENT LIGHT ZONE 2, 21 & 22 TECHNICAL DRAWINGS C C D D B B A A Front View Single lamp Front View Twin lamp LIGHT DISTRIBUTION CURVE 0 90º 0 90º 0 90º º 80 60º 80 60º º 30º 160 0º 30º 160 0º 30º 18W x 1 18W x 2 36W x 1 Fluroescent & LED Lighting 0 90º 0 90º 0 90º º 80 60º 80 60º º 30º 160 0º 30º 160 0º 30º 36W x 2 58W x 1 58W x 2 brenclosures.com.au Hazardous Areas 89
92
93 Plug & Socket Outlets
94 PLUG & SOCKET OUTLETS ZONES 1 & 2, 21 & 22 MATERIALS Body SMC anti-static Surface finish Textured matt black OPTIONS Plug Socket outlets Panel socket outlet and coupler socket also available as an option CERTIFICATION IECEx CQM (16A) IECEx CQM U (32A) IECEx CQM (63A & 125A) IECEx CQM U (Panel) PROTECTION Ex de IIC Gb Ex td A21 AMBIENT TEMPERATURE -40ºC ~ +45ºC / 55ºC option Range: CZ0251 (16Amp) CZ0252 (32Amp) CZ0253 (63Amp) CZ0254 (125Amp) IP 66 OVERVIEW Designed to provide electrical connection within a hazardous area for mobile or portable equipment. Designed with a switch on the inside, the Ex de connection prevents sparking and is high impact resistant. FEATURES Internal brass gland plate Self-cleaning inserting sleeve and contact joints Protective cover for high degree of protection Minimal force required when inserting or extracting Internal switch >32A and external switch for <32A TECHNICAL DRAWINGS B E C Dimensions (mm) Fixing Dimensions (mm) Type Height (A) Width (B) Depth (C) Height (D) Width (E) 16Amp 2 Poles D 16Amp 3 Poles A 16Amp 4 Poles Amp 4 Poles Amp 4 Poles Amp 4 Poles Type Width (mm) Diameter (mm) 16Amp 2 Poles Amp 3 Poles Width Diameter 16Amp 4 Poles Amp 5 Poles Amp 4 Poles Amp 4 Poles Amp 4 Poles Hazardous Areas
95 PLUG & SOCKET OUTLETS ZONES 1 & 2, 21 & 22 SELECTION GUIDE PLUGS SELECTION GUIDE SOCKETS Catalogue No. Entries Amps Volts Colour Pins SO-PG016A024VSP 24V 2P SO-PG016A042V2P 42V 2P SO-PG016A110V2PE 110V 1PN+E SO-PG016A240V2PE 220V 1PN+E SO-PG016A240V3PE 2 x M25 16A 220V 3P+E SO-PG016A415V3PE 400V 3P+E SO-PG016A490V3PE 480V 3P+E SO-PG016A690V3PE 615V 3P+E SO-PG016A415V4PE 400V 3PN+E SO-PG032A240V3PE 220V 3P+E SO-PG032A415V3PE 400V 3P+E SO-PG032A490V3PE 2 x M32 32A 480V 3P+E SO-PG032A690V3PE 615V 3P+E SO-PG032A415V4PE 400V 3PN+E SO-PG063A240V3PE 220V 3P+E SO-PG063A415V3PE 400V 3P+E SO-PA063A415V3PE 400V 3P+E Auxillary SO-PG063A490V3PE 480V 3P+E SO-PA063A490V3PE 2 x M50 63A 480V 3P+E Auxillary SO-PG063A690V3PE 615V 3P+E SO-PA063A690V3PE 615V 3P+E Auxillary SO-PG063A415V4PE 400V 3P+E SO-PA063A415V4PE 400V 3P+E Auxillary SO-PG125A240V3PE 220V 3P+E SO-PG125A415V3PE 400V 3P+E SO-PA125A415V3PE 400V 3P+E Auxillary SO-PG125A490V3PE 480V 3P+E SO-PA125A490V3PE 2 x M63 125A 480V 3P+E Auxillary SO-PG125A690V3PE 615V 3P+E SO-PA125A690V3PE 615V 3P+E Auxillary SO-PG125A415V4PE 400V 3P+E SO-PA125A415V4PE 400V 3P+E Auxillary Sockets Product Catalogue No. Entries Amps Volts Colour Pins SO-SW016A024V2P 24V 2P SO-SW016A042V2P 42V 2P SO-SW016A110V2PE 110V 2P+E SO-SW016A240V2PE 220V 2P+E SO-SW016A240V3PE 2 x M25 16A 220V 3P+E SO-SW016A415V3PE 400V 3P+E SO-SW016A490V3PE 480V 3P+E SO-SW016A690V3PE 615V 3P+E SO-SW016A415V4PE 400V 3PN+E SO-SW032A240V3PE 220V 3P+E SO-SW032A415V3PE 400V 3P+E SO-SW032A490V3PE 2 x M32 32A 480V 3P+E SO-SW032A690V3PE 615V 3P+E SO-SW032A415V4PE 400V 3PN+E SO-SW063A240V3PE 220V 3P+E Wall Panel Coupler SO-SW063A415V3PE 400V 3P+E SO-SA063A415V3PE 400V 3P+E Auxillary SO-SW063A490V3PE 480V 3P+E SO-SA063A490V3PE 2 x M50 63A 480V 3P+E Auxillary SO-SW063A690V3PE 615V 3P+E SO-SA063A690V3PE 615V 3P+E Auxillary SO-SW063A415V4PE 400V 3PN+E SO-SA063A415V4PE 400V 3PN+E Auxillary SO-SW125A240V3PE 220V 3P+E SO-SW125A415V3P 400V 3P+E SO-SA125A415V3PE 400V 3P+E Auxillary SO-SW125A490V3PE 480V 3P+E SO-SA125A490V3PE 2 x M63 125A 480V 3P+E Auxillary SO-SW125A690V3PE 615V 3P+E SO-SA125A690V3PE 615V 3P+E Auxillary SO-SW125A415V4PE 400V 3PN+E SO-SA125A415V4PE 400V 3PN+E Auxillary SO-SP016A024V2P 24V 2P SO-SP016A042V2P 42V 2P SO-SP016A110V2PE 110V 1PN+E SO-SP016A240V2PE 220V 1PN+E SO-SP016A240V3PE 2 x M25 16A 220V 3P+E SO-SP016A415V3PE 400V 3P+E SO-SP016A490V3PE 480V 3P+E SO-SP016A690V3PE 615V 3P+E SO-SP016A415V4PE 400V 3PN+E SO-SP032A240V3PE 220V 3P+E SO-SP032A415V3PE 400V 3P+E SO-SP032A490V3PE 2 x M32 32A 480V 3P+E SO-SP032A690V3PE 615V 3P+E SO-SP032A415V4PE 400V 3PN+E SO-SC016A024V2P 24V 2P SO-SC016A042V2P 42V 2P SO-SC016A110V2PE 110V 1PN+E SO-SC016A240V2PE 220V 1PN+E SO-SC016A240V3PE 2 x M25 16A 220V 3P+E SO-SC016A415V3PE 400V 3P+E SO-SC016A490V3PE 480V 3P+E SO-SC016A690V3PE 615V 3P+E SO-SC016A415V4PE 400V 3PN+E SO-SC032A240V3PE 220V 3P+E SO-SC032A415V3PE 400V 3P+E SO-SC032A490V3PE 2 x M32 32A 480V 3P+E SO-SC032A690V3PE 615V 3P+E SO-SC032A415V4PE 400V 3PN+E Plug & Socket Outlets brenclosures.com.au Hazardous Areas 93
96
97 Weatherproof Lighting & Enclosures
98 ALUMINIUM WEATHER-PROOF FLOODLIGHT MATERIALS Body Copper-free aluminium alloy Glass tube Toughened glass Ballast Electronic Rated voltage AC 220V, 50/60Hz Surface finish Powdercoated grey INCLUSIONS Mounting accessories UV resistant lens PROTECTION WF1, IP66 AMBIENT TEMPERATURE -40ºC Ta 50ºC Range: M0874/3 Series IP 66 OVERVIEW The weather-proof floodlights are manufactured from aluminium alloy giving exceptional corrosion resistance. An impact resistant polycarbonate lens, weatherproof terminal box make this unit suitable for extreme conditions. FEATURES Convenient mounting and ease-of-service Multiple mounting options available Energy saving lm SELECTION GUIDE Dimensions (mm) Catalogue No. Width Height Mounting Weight (kg) ESA40FLD/C/WP Bracket 7.0 ESA40FLD/P9/WP Pole 90º 7.0 ESA40FLD/P2/WP Pole 25º 7.0 ESA40FLD/W/WP Wall 7.0 INSTALLATION ACCESSORIES Product Description Catalogue No. Brackets Straight pipe Lamp poles For ceiling mount D8722/2 For general mounting D8701/2 For pendant mounting D8702/2 ¾" galvanised steel pipe with powdercoated surface Fence type (set) Flange type (set) D732 D8725 D8726 Bracket mount 90º Pole mount 96 Hazardous Areas 25º Pole mount Wall mount
99 ALUMINIUM WEATHER-PROOF FLOODLIGHT TECHNICAL DRAWINGS Weatherproof 235mm 300mm 232mm 485mm 262mm Front View bracket mount Front View 90º pole mount 235mm 415mm Front View 25º pole mount 420mm Front View wall mount LIGHT DISTRIBUTION CURVE -90º 0 90º º º 0º 30º 60º brenclosures.com.au Hazardous Areas 97
100 NON-METALLIC CONTROL BOX MATERIALS Body Glass reinforced polyester Rated voltage 380V maximum INCLUSIONS Control box Customised to suit application requirements AMBIENT TEMPERATURE -40ºC Ta +40ºC / 55ºC option Range: M0242 IP 65 OVERVIEW A range of non-metallic control boxes for applications that do not require stainless steel. Glass fibre reinforced polyester is weatherproof and anti-corrosive. FEATURES Individual enclosures can be combined into large units Standard pitch between two components is 40mm Built-in board front mounting rail type Cable entry can be set to the top, bottom, left or right side of the control box Cable gland can be metal or plastic 98 Hazardous Areas
101 NON-METALLIC CONTROL BOX SELECTION GUIDE! These enclosures are sold with controls and terminals fitted. Empty enclosures are not available for sale. Contact your local sales engineer to discuss your specific requirements. Dimensions (mm) Height Width Depth Catalogue No. Max. number of operators (A) (B) (C) WTBG2A WTBG2B WTBG WTBG WTBG WTBG WTBG TECHNICAL DRAWINGS A B C Front View Side View Weatherproof brenclosures.com.au Hazardous Areas 99
102 NON-METALLIC WEATHERPROOF CONTROL BOX MATERIALS Body SMC polyester Rated voltage 380V maximum INCLUSIONS Control box 3 standard sizes 1 9 installed componenets Custom built to suit application requirements AMBIENT TEMPERATURE -40ºC Ta +55ºC / 40ºC option Range: M0242 IP 65 OVERVIEW A range of non-metallic control boxes for applications that do not require stainless steel. Glass fibre reinforced polyester is weatherproof and anti-corrosive. FEATURES Three types of standard enclosures Explosion-proof operation head fitted to make enclosure more reliable and durable Easy to install Flexible configurations Stable and high anti-corrosion chemical performance Two types of vertical foot trays Ammeter, signal, switch and start/stop options available Pendant, pipe or vertical mounting options 100 Hazardous Areas
103 NON-METALLIC WEATHERPROOF CONTROL BOX SELECTION GUIDE! These enclosures are sold with controls and terminals fitted. Empty enclosures are not available for sale. Contact your local sales engineer to discuss your specific requirements. Dimensions (mm) Height Width Depth Catalogue No. Max. number of operators (A) (B) (C) WCSG WCSG WCSG TECHNICAL DRAWINGS Weatherproof A B C Front View Side View brenclosures.com.au
104 Head Office 51 Stradbroke Street Heathwood QLD 4110 Australia PO Box 1151 Browns Plains BC QLD 4118 Australia T: F: QLD Office Sales & Warehouse 51 Stradbroke Street Heathwood QLD 4110 Australia PO Box 1151 Browns Plains BC QLD 4118 Australia T: F: North QLD Office Sales & Warehouse 25 Dalrymple Road Garbutt QLD 4814 Australia PO Box 7615 Garbutt QLD 4815 Australia T: F: NSW & ACT Office Sales & Warehouse Unit 12/100 Belmore Road North Riverwood NSW 2210 Australia PO Box 90 Riverwood NSW 2210 Australia T: F: Newcastle Distribution Ross Joice Agencies Pty Ltd Broadmeadow Road Broadmeadow NSW 2292 Australia T: F: VIC & TAS Office Sales & Warehouse Sunmore Close Heatherton VIC 3202 Australia T: F: SA & NT Office Sales & Warehouse 505 Grand Junction Way Wingfield SA 5013 Australia T: F: Northern Territory Distribution Jewell Distributors Pty Ltd Cnr Hidden Valley & Beaton Roads Berrimah NT 0828 Australia T: F: WA Office Sales & Warehouse 6 Montgomery Way Malaga WA 6090 Australia T: F: National Sales T: 1300 Enclosures ( ) F: E: sales@brenclosures.com.au brenclosures.com.au
TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22
Hazardous Area Electrical Equipment TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBKS/CBKS Information Page Ask
More informationHazardous Area Electrical Equipment. TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22. Index
Hazardous Area Electrical Equipment Made TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBKF/CBKF Information Page
More informationEJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...
EJB Enclosures ATEX and IECEx Zone 1 certified Explosion proof Marine grade copper-free aluminium IP66 The EJB Series is a range of explosion-proof enclosures, available in either aluminium alloy (EJB)
More informationATEX LABELLING FOR MOTORS AND GEAR UNITS
ATEX LABELLING FOR MOTORS AND GEAR UNITS EN ATEX INFORMATION GAS AND DUST COMPLETE DRIVE SOLUTIONS FROM A SINGLE SOURCE RELIABLE n Reliable products n Coordinated components n NORD's own development and
More informationReg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 Equipment: Manufacturer: Type: ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION
More informationEX-D ENCLOSURES AND DISTRIBUTIONS
EX-D ENCLOSURES AND DISTRIBUTIONS Series GHG made of metal for gases of explosion group IIC To use MCBs, fuses, contactors etc. which give off arcs in potentially hazardous areas, they must be integrated
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL
More informationALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES
Ex d IIB+H 2 ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES ALUMINIUM ENCLOSURES STAINLESS STEEL ENCLOSURES EJB... series enclosures offer Ex d IIB +H 2 mode of protection. These enclosures are
More informationK Series 3 Way Direct Acting Balanced Poppet Solenoid Valve
Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS
More informationExplosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion
Ex-protection Explosion protection Valves for fluid technology for use in explosion hazard areas Explosion protection for gas, dust and mining Flameproof enclosures and intrinsic safety Solutions for all
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion
EX-PROTECTION ADVANTAGES Valves for fluid technology for use in explosion hazard areas Explosion protection for gas, dust and mining Flameproof enclosures and intrinsic safety Solutions for all zones The
More informationGeneral Purpose Enclosures. Universal NI - Zinc Coated Steel General Purpose Enclosure - IP66. Index
General Purpose Enclosures Universal NI - Zinc Coated General Purpose Enclosure - IP66 Index Dimension Sheet Dimension Sheet Viewing Window Information Leafl et Web Links Universal NI Information Page
More informationVALIADIS S.A. HELLENIC MOTORS
Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe
More informationFlameproof Enclosures
Flameproof Enclosures The range comprises many standard sizes of enclosures manufactured in stainless steel 316L and/or in painted carbon steel. The enclosures allow for utilization of standard electrical
More informationCCAI, CCAIF, CCAIF..H
CCAI, CCAIF, CCAIF..H - Zone 1, 2, 21, 22 - Group IIC - Stainless steel junction boxes - Choice of 4 sizes - IP66 AISI 316L stainless steel Grub screws for opening lid Lid opening system Detail of inside
More informationSolutions Ex d IIB+H2, Aluminum and Stainless Steel
Features Assembly examples Enclosures manufactured from copper-free aluminum or AISI 316L stainless steel Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d IIB+H2 and Ex tb More than 40 enclosure
More informationPetroleum industries are dealing with different hazardous materials starting from storing, processing and distributing the petroleum products These he
FIRE SAFETY OF PETROLEUM INDUSTRIES By- Debapriya Biswas Additional Director General West Bengal Fire & Emergency Services Petroleum industries are dealing with different hazardous materials starting from
More informationPower (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13
Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.
More informationEx e, ia Junction boxes TNCN. Features
TNCN Features The TNCN/TNCC range comprises many standard sizes of enclosure manufactured in 316L acid resistant stainless steel to give the maximum environmental protection. The main body is manufactured
More informationHKH Series. HAZCON Controls for Harsh and Hazardous Environments
HKH Series HAZCON Controls for Harsh and Hazardous Environments Z A H LO C NON-METALLIC DIN RAIL MOUNT Component Mounting Rail Optional Customer I.D. Nameplate Optional Legend Plate Explosion Protective
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More informationEmergency Light Fitting for Fluorescent Lamps Series 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationGOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Reg No: 1999/027771/07 (Pty) Ltd 7 Spanner Rd / PO Box 467 Olifantsfontein 1665 Tel: +27 (11) 316 4601 Fax: +27 (11) 316 5670 E-mail: admin-mgr@explolabs.co.za GOVERNMENT APPROVED TEST LABORATORY IN TERMS
More informationJunction boxes for control, monitoring and control panel Ex tb
Junction boxes for control, monitoring and control panel - Zone 21, 22 - Category 2D - Aluminium, reinforced polyester or stainless steel enclosures - Standard or custom products Inspection window Padlockable
More informationGeneral Purpose Enclosures. Universal NI Stainless Steel General Purpose Enclosure - IP66. Index
General Purpose Enclosures Universal NI - 316 Stainless Steel General Purpose Enclosure - IP66 Index Dimension Sheet Dimension Sheet Viewing Window Information Leafl et Web Links Universal NI SS Information
More informationSolutions Ex d IIB+H2, Stainless Steel EJBX*
Features Assembly Examples Enclosures manufactured from AISI 316L stainless steel Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d IIB+H2 and Ex tb More than 20 enclosure size options Free
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationLinear luminaire with LED Series EXLUX 6002
> latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More information11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**
Assembly Instructions for: S1 Assembly to S Junction Instructions Boxes for: MS1 to MS Junction Boxes Boxes MS1 to MS Junction Boxes IMPORTANT: This document should be read carefully before commencing
More informationCompact Sheet-Steel Light Fittings Series 6114/1
> As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive
More informationEX CABLE GLANDS FOR HAZARDOUS AREAS ATEX & IECEX. Zones 1, 2, 21 and 22.
EX CABLE GLANDS FOR HAZARDOUS AREAS & IECEX Zones, 2, 2 and 22 CABLE GLANDS EX D/E 4 CABLE GLANDS UNARMOURED EX D IP66 - IP68 5 CABLE GLANDS UNARMOURED EX E IP66 - IP68 5 CABLE GLANDS UNARMOURED EX D/E
More informationFloodlight LED Series 6125
www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated
More informationFlameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C
Enclosures Flameproof - Group IIB or IIB + 2 Carbon steel - DE8BC series The flameproof control cabinets DE8BC are designed for the control, automation, distribution boards, motor starters or any other
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless
More informationEJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.
EJB Stainless steel bolts - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67 Mounting bracket Hinges in stainless steel Warning labels Silicone gasket between
More informationGOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Reg No: 1999/027771/07 (Pty) Ltd 7 Spanner Rd / PO Box 467 Olifantsfontein 1665 Tel: +27 (11) 316 4601 Fax: +27 (11) 316 5670 E-mail: admin-mgr@explolabs.co.za GOVERNMENT APPROVED TEST LABORATORY IN TERMS
More informationFloodlight Series 6121
www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options
More informationOperating Instructions
Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety
More informationYFC. Limit switch. Ex d. 24 operating head types
Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735
More informationSwitches in conformity with ATEX directive
Switches in conformity with ATX directive 2/3 General Catalog 3-4 Technical concepts page 2/39 Position switches FD series page 2/4 Category Zone PL Approvals 2G Gb Mb II 2G x ia IIC T6 Gb I x ia I Mb
More informationLoad disconnect switch Series 8146/5-V11
www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation
More informationLinear Luminaire with LED Series EXLUX 6002
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationJBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped
Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes Applications Instrumentation junction boxes are used to run process or remote information to control room. For
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationM-0. M-0... series control, monitoring and signalling devices. Ex e
M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere
More information5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A
.1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility
More informationHazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours
MIE TALK - July 2016 Compiled by Pieter H. Coetzee Introduction Far too many fires and burn injuries result from the careless or inappropriate use of petrol. Because petrol is so common in our environment,
More informationProportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06
www.atos.com Table TF040-2/E Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 A B DHRZO-A-012/25 A B DHRZA-A-010/25 DHRZ* are
More informationexplosive environments Lighting
explosive environments Lighting CLASSIFICATION OF THE ZONES GAS AND VAPOURS DUST PRESENCE OF EXPLOSIVE ATMOSPHERE ZONE 0 ZONE 20 Category 1G Category 1D Permanent ZONE 1 ZONE 21 Category 2G Category 2D
More informationWellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22
WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder
More informationTable of contents. Technical informations > ATEX Page Technical informations Page Mechanically operated valves Page 13-06
Technical informations > Table of contents ATEX Page 13-02 Technical General informations information Page 13-02 Mechanically operated valves Page 13-06 Pneumatically operated valves Page 13-06 Electrically
More informationB&R Enclosures CAUTION AUDIO & VISUAL BBJ SERIES LED. brenclosures.com.au
B&R Enclosures CAUTION AUDIO & VISUAL BBJ SERIES LED brenclosures.com.au RAL7040 IP 65 features & benefits Ultra bright LED lamps Energy efficient Low power consumption Lamp power 2W Flash frequency of
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet painted > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationVersions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve
Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE
More informationSwitches in conformity with ATEX directive
Switches in conformity with ATX directive 2/3 General Catalog -2 Technical concepts page 2/39 Position switches FD series page 2/4 Category Zone PL Approvals 2G Gb Mb II 2G x ia IIC T6 Gb I x ia I Mb Article
More informationCompact temperature switch Model TCS
Mechatronic temperature measurement Compact temperature switch Model TCS WIKA data sheet TV 31.64 Process Compact Series Applications Temperature monitoring and control of processes Safety-critical applications
More informationILED Dorado. User Manual
10NM U-code Medium Intensity Obstruction Light Helideck Status Light 15NM U-code Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description...
More informationExplosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS
Ex d Ring Enclosure Ex e Terminal Boxes Hollow Option Ambient Temperature Maximum Throughput Current Protection Mounting (increased range available) 20 rpm (higher on request) 770V ac 1166 Amps In any
More informationThe ultimate low voltage temporary LED lighting solution
LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkExTM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts
More informationExplosionproof enclosures XPCJ series Cast aluminum steel control/junction box
1 TECHNICAL DATA SHEET Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box XPCJ series series of explosionproof aluminum enclosures are typically used in the packaging of electrical/electronic
More informationby Jim Phillips, P. E.
by Jim Phillips, P. E. Baking flour, coal dust and gasoline; what do these things have in common? They are not the ingredients for a strange new cake recipe. Each of these ingredients is the fuel that
More informationP SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE
P SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE A BREAKER PROTECTION BREAKTHROUGH Simplify flameproof protection for lighting, heat trace and power circuit distribution with the new generation
More informationBFG range BFGC range BFN range
BFG range BFGC range BFN range LOW AND MEDIUM VOLTAGE MOTORS FOR HAZARDOUS AREAS EEx d EEx de EEx na - Flameproof Motors - Flameproof Motors With Increased Safety Terminal Box - Non Sparking Motors TABLE
More informationGuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4
1. Introduction: This instruction manual contains important information regarding the safety instructions, installation, operation, maintenance and storage of the Guardbox limit switch boxes. The limit
More informationCompact Sheet-steel Emergency Light Fitting Series 6118/1
www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic
More informationEx eb IIC Gb Ex ia IIC Ga Ex Tb IIIC Db DRILLING AND ASSEMBLY OF JBEP JUNCTION BOXES AND ENCLOSURES GUIDE
Ex eb IIC Gb Ex ia IIC Ga Ex Tb IIIC Db DRILLING AND ASSEMBLY OF JBEP JUNCTION BOXES AND ENCLOSURES GUIDE To easily accommodate your unique application requirements and maintain compliance with certification
More informationNew products Ex Equipment 2015
New products Ex Equipment 2015 ROSE Systemtechnik GmbH ROSE Systemtechnik GmbH was founded in Porta Westfalica, Germany, in 199 and is today one of the world s leading and innovative providers of industrial
More informationEmergency Luminaire with LED Series EXLUX 6009/1 Version IIC
> For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central
More information7 Lighting Technology
7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:
More informationExplosion and flame-proof single phase electric motors
Explosion and flame-proof single phase electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 112 Single phase Voltage 230 50Hz Voltage 265 60Hz Types of mounting
More informationThe ultimate low voltage temporary LED lighting solution
LED Tank Lighting Kits The ultimate low voltage temporary LED lighting solution Temporary LinkEx TM LED ambient and task low voltage lighting for hazardous areas where potentially explosive gases and dusts
More informationJunction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety
JBES Series Medium Voltage 11 kv ECES Series Compliance Data: ATEX - IEC: ATEX IEC CE Ex e II Ex ia IIC; Ex ib IIC T6 to T4 Ex td A21 T80 C to T130 C Ex de IIC; Ex demb IIC Operating Temperatures: -50
More informationSynergEX Panelboards. Installation & Maintenance Information IF Panelboards for Hazardous Locations SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
SynergEX Panelboards Panelboards for Hazardous Locations Installation & Maintenance Information IF 1659 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CAUTION Read these operating instructions and all other
More informationLight Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400
> As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS RTECK terminal boxes RTKB series IEC Ex EX010 TECHNICAL FILES CONTENTS: 1) Contents 2) General information 3) Safety information 4) Conformity to standards 5) Function 6) Technical
More informationBFG range BFGC range BFN range
BFG range BFGC range BFN range LOW AND MEDIUM VOLTAGE FOR HAZARDOUS AREAS EEx d EEx de EEx na - Flameproof Motors - Flameproof Motors With Increased Safety Terminal Box - Non Sparking Motors 1. MARKING
More informationExplosion and flame-proof cast iron electric motors
Explosion and flame-proof cast iron electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 160 3 phases Voltage 230/400 V 50Hz Voltage 265/460V 60Hz Types of mounting
More informationTABLE OF CONTENTS DISCLAMER
PRODUCT CATALOGUE TABLE OF CONTENTS Introduction 2 Series 170 3 Series 178 4 Series 251 5 Series 351 7 Series 363 9 Series 800 10 Series 810 11 Series 820 12 Series 850 13 Series 900 14 Series 950 15
More informationSPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot
SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationB&R Enclosures FROG SERIES LED. brenclosures.com.au
B&R Enclosures FROG SERIES LED brenclosures.com.au RAL7040 IP 66 features & benefits Can be used as a spotlight, floodlight, area light, street light, high bay and lowbay depending on choice of optics
More informationCOMBUSTION AND ENERGY
CATALOGUE 2015 COMBUSTION AND ENERGY COMBUSTION AND ENERGY SRL VIA PER DOLZAGO, 21-23848 OGGIONO (LC) - ITALY - PH. +39 0 341.260926 - FAX +39 0 341.577747 INTERNATIONAL STANDARDS The ATEX directive consists
More information2011 ilinq CATALOGUE
2011 ilinq CATALOGUE Company Overview A brand built on quality B&R Enclosures is Australia s leading manufacturer of electrical enclosures, with a comprehensive range of products designed for industrial
More informationModel 5000 Level Controller
Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap
More informationEmergency Luminaire with LED Series EXLUX 6409/1
> Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually
More informationB&R Enclosures AROWANA SERIES LED. brenclosures.com.au
B&R Enclosures AROWANA SERIES LED brenclosures.com.au RAL7040 IP 66 features & benefits More light, less power. Reduce the number of luminaires or add more light. Micro optics reduces direct visual contact
More informationThe B&R Group GENERAL CATALOGUE
GENERAL CATALOGUE Our Valued Customers, Industrial Enclosures & Switchboards B&R Enclosures is Australia s largest manufacturer of enclosures, racks, cabinets, switchboard building systems to applications
More informationMercmaster LED Series Luminaires Enclosed and Gasketed Fixtures
Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical
More informationProtecta III. Acclaim. Curie Elite. Lomond. Evolution II. Nevis. NexLED. Sterling II. 800 Series. Micronex/Maxinex. Nexxus II.
Protecta III Acclaim Curie Elite Lomond Evolution II Nevis NexLED Sterling II 800 Series Micronex/Maxinex Nexxus II Eclipse II CHALMIT LIGHTING 2 Chalmit Lighting, formerly known as Andrew Chalmers and
More informationHigh voltage flameproof induction motors The simplest solution for hazardous environments
High voltage flameproof induction motors The simplest solution for hazardous environments We offer motors and generators, services and expertise that save energy and improve our customers processes over
More informationGRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators
Ex d GRD-4200 Electronic earthing system - Zone 1, 2, 21, 22 - High quality electronic components - High resistance to corrosion and extreme weather - Safe and reliable over time SIL certified Level 2
More informationFloodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
More informationSTAINLESS STEEL PANEL MOUNT
Z A H LO C STAINLESS STEEL PANEL MOUNT Optional Legend Plate Cover Screw Retaining Washer Panel Mount Bracket Explosion Protective LED Pilot Light Stainless Steel Washer Actuator Spacer Locknut Explosion
More informationMini temperature switch Stainless steel switch enclosure Model TXS
Mechatronic temperature measurement Mini temperature switch Stainless steel switch enclosure Model TXS WIKA data sheet TV 31.70 Process Mini Series Applications Temperature monitoring and control of processes
More informationTerminal Boxes TNCN. Explosion protection Marking
Terminal boxes TNCN Terminal Boxes TNCN The TNCN range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main box is manufactured
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX 6600
> 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More information