technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

Size: px
Start display at page:

Download "technical data Systems FXMQ-MVE Conceiled ceiling unit (large)"

Transcription

1 technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

2 FXMQ-MVE 11 Concealed ceiling unit (large) 11 1 Features Specifications Technical specifications...3 Electrical specifications...4 Safety device settings Accessories Drain pump kit...6 High efficiency filter...8 Replacement long life filter Control systems Capacity tables Cooling capacity...12 Heating capacity Dimensions Dimensional drawings...16 Dimensional drawings with drain pump kit...18 Dimensional drawings with high efficiency filter/long life filter...20 Centre of gravity...21 Bolt pitch Piping Diagram Wiring Diagrams Sound level Fan characteristics Installation...28 Systems Indoor Units 217

3 1 Features Leaves maximum wall space for furniture and decoration Wide line-up to increase the flexibility in system designing: complete range of models ( kw) More than 150Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas External static pressure can be easily adjusted using a change-over switch inside the electrical box to meet the resistance in the duct system Built-in drain pump (accessory) : housing the drain pump inside the unit has reduced the necessary installation space Indoor unit Drain pump kit 120 Min. 590 mm BUILT-IN DRAIN PUMP Min. 470 mm Indoor unit 40~80 type 200~250 type 100~125 type Systems Indoor Units

4 2 Specifications 2-1 Technical specifications FXMQ-MVE COOLING CAPACITY (1) kw HEATING CAPACITY (2) kw NOMINAL INPUT Cooling W ,294 1,465 Heating W ,294 1,465 DIMENSIONS HxWxD mm 390x720x x1,110x x1,380x1,100 WEIGHT kg CASING galvanised steel plate SOUND LEVEL Sound pressure 220V high dba low dba Sound power dba * * * * * FAN Air flow rate high m 3 /h 840 1,170 1,740 2,160 3,480 4,320 low m 3 /h ,380 1,740 3,000 3,720 Type sirocco fan Model D11/2D3AB1VE D11/2D3AA1VE 2D11/2D3AG1VE 2D11/2D3AF1VE D13/4G2DA1x2 Motor output W x380 External static pressure (50Hz) (Cf. note 4) Pa Drive direct drive HEAT EXCHANGER Rows x stages x fin pitch mm 3x16x2.0 3x26x2.0 Face area m AIR FILTER cf. note 5 REFRIGERANT CONTROL electronic expansion valve TEMPERATURE CONTROL microprocessor thermostat for cooling and heating PIPING CONNECTIONS Liquid flare mm ø 6.4 ø 9.5 ø 9.5 Gas mm ø 12.7 (flare) ø 15.9 (flare) ø 19.1 (brazing) Drain mm VP25, external diameter 32, internal diameter 25 PS1B SOUND ABSORBING INSULATION MATERIAL glass fiber ø 22.2 (brazing) 3D Nominal cooling capacities are based on: Indoor temperature: 27 CDB, 19 CWB Outdoor temperature: 35 CDB Equivalent refrigerant piping: 7.5m (horizontal) 2 Nominal heating capacities are based on: Indoor temperature: 20 CDB Outdoor temperature: 7 CDB, 6 CWB Equivalent refrigerant piping: 7.5m (horizontal) 3 Capacities are net including a deduction for cooling (an addition for heating) for indoor fan motor heat. 4 Static external pressure is changeable: change the connectors inside the electrical box, this pressure means: high static pressure - standard 5 The air filter is not a standard accessory, but please mount it in the duct system at the suction side. Select its colorimetric method (gravity method) 50% or more * Data were not available at the time of publication 2 Systems Indoor Units 219

5 FAN MOTOR THERMAL PROTECTOR C OFF: 135 ±8, ON: 87 ±15 3D034597B 2 Specifications 2-2 Electrical specifications FXMQ-MVE CURRENT Minimum circuit amps (MCA) A Maximum fuse amps (MFA) A 15 POWER SUPPLY VE 1 ~, 50Hz, V VOLTAGE RANGE Min~max V 198 ~ 264 INDOOR FAN MOTOR Fan motor rated output W x2 Full load amps (FLA) A D Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed range limits. 2 Maximum allowable voltage range variation between phases is 2%. 3 MCA/MFA: MCA = 1.25 x FLA MFA 4 x FLA next lower standard fuse rating minimum 15A. 4 Select wire size based on the MCA. 5 Instead of a fuse, use a circuit breaker 6 For more details concerning conditional connections, see select "Daikin Documentation" and select "conditional connection", "the requested product type" and "English" from the drop down lists, click the search button. Finally, click on the document title of your choice. 2-3 Safety device settings FXMQ-MVE PC BOARD FUSE 250V 10A Systems Indoor Units

6 3 Accessories FXMQ-MVE DRAIN PUMP KIT KDU30L125VE KDU30L250VE HIGH EFFICIENCY FILTER 65% KAFJ302L71 KAFJ302L140 KAFJ372L280 HIGH EFFICIENCY FILTER 90% KAFJ303L71 KAFJ303L140 KAFJ373L280 FILTER CHAMBER KDDJ30L71 KDDJ30L140 KDJ3705L280 REPLACEMENT LONG LIFE FILTER KAFJ301L71 KAFJ301L140 KAFJ371L280 3D040334A Main Unit High Efficiency Filter Drain Pump Kit Filter Chamber High Efficiency Filter 3 Systems Indoor Units 221

7 3 Accessories 3-1 Drain pump kit Specifications KDU30L125VE KDU30L250VE POWER SUPPLY single phase v/220v 50/60hz POWER CONSUMPTION W 19/17 (50/60hz) DRAIN-UP LIFT mm standard drain outlet of the unit +294 standard drain outlet of the unit +197~+447 DRAIN OUTLET VP25 (internal diameter ø25, external diameter ø32) SAFETY DEVICE float switch WEIGHT kg 9 10 APPLIED MODELS class class Precaution at use When this kit will be used together with the natural evaporation pan type humidifier, the piping of unit's drain and humidifier's drain can be used in common. Be sure to do test run (cooling) to make sure the drain flows out. Prohibit providing a drain trap when the drain pump kit will be mounted Installation Spot hose Drain hose Drain hose insulation Drain pipe insulation Hose band 1 Connect the drain connection hose from the elbow of the connection hose to the drain pump box. Connect the attached drain hose to the outlet of the drain pump. 2 Keep the drain hose sloping downwards. Hose band Hose band Drain connection Elbow 3 Ceiling slab more KDU30L125VE KDU30L250VE A 520 mm 590 mm Indoor unit Ceiling Drain pump kit 222 Systems Indoor Units

8 3 Accessories 3-1 Drain pump kit Internal wiring method KDU30L125VE Indoor unit Drain pump lead wire Clamps Drain pump wires Float switch Float switch wire X8A Indoor PC board assembly (Indoor unit) Remove the short circuit connector?(drain pump kit) Electric parts box Drain pump kit Electric parts box cover Float switch lead wire KDU30L250VE Fan partition plate Relay harness (1) Drain pump lead wire 3 Float switch lead wire Float switch Drain plug Indoor PC board assembly X8A?(Drain pump kit) (Indoor unit) Remove the short circuit connector Insulator (1) Drain pump lead wire Remove a cushion Float switch lead wire Systems Indoor Units 223

9 3 Accessories 3-2 High efficiency filter Specifications 65% type 90% type KAFJ302L71 KAFJ302L140 KAFJ372L280 KAFJ303L71 KAFJ303L140 KAFJ373L280 FILTER CHAMBER KDDJ30L71 KDDJ30L140 KDJ3705L280 KDDJ30L71 KDDJ30L140 KDJ3705L280 DIMENSION WxDxT mm 545x270x25 468x270x25 684x445x60 545x270x25 468x270x25 684x445x60 AVERAGE DUST COLLECTION EFFICIENCY % colorimetric method 65% colorimetric method 90% INITIAL PRESSURE LOSS Pa FINAL PRESSURE LOSS Pa FILTER non-woven fabric of synthetic fiber non-woven fabric of synthetic fiber LIFE TIME h 2,500 hours (dust density 0.15mg/m 3 ) 1,800 hours (dust density 0.15mg/m 3 ) SEATS STRUCTURED APPLICABLE MODELS 40 class 50,63,80 class 100 class 125 class 200,250 class 40 class 50,63,80 class 100 class 125 class 200,250 class NOTE 1 The filter chamber is separately required when the high efficiency filter will be installed Dimensions 545 (L71) 468 (L140) 684 (L280) Air flow Filter medium (L71 140) 445 (L280) 25 (L71 140) 60 (L280) 224 Systems Indoor Units

10 3 Accessories 3-2 High efficiency filter Filter characteristics Pressure loss KAFJ303L71 KAFJ302L71 KAFJ303L140 KAFJ302L140 KAFJ373L280 KAFJ372L280 (Pa) Air volume (m 3 /min) Installation Wing nut Main unit Cover for filter chamber Screw Filter chamber (KDDJ30L type) Air suction flange (supplied) 3 Air flow Screw High efficiency filter (option) Air suction duct (field supply) Meet the airflow direction and arrow mark putting on the high efficiency filter. It is impossible to be built in together with the air cleaning unit Systems Indoor Units 225

11 3 Accessories 3-3 Replacement long life filter Specifications Dimensions KAFJ301L71 KAFJ301L140 KAFJ371L280 FILTER CHAMBER FOR BOTTOM SUCTION KDDJ30L71 KDDJ30L140 KDJ3705L280 DIMENSIONS WxDxT mm 547x252x30 419x252x30 684x445x30 519x252x30 AVERAGE EFFICIENCY (%) % 50% (gravity method) PRESSURE LOSS (PA) Initial Pa 9.8 (1 mmh2o) Final Pa 49 (5 mmh2o) MATERIAL mildew proof resin net NUMBER REQUIRED PER UNIT 1 2 (each 1) 2 LIFE TIME (H) h 2,500 h (dust particle concentration at 0.15mg/m 3 ) APPLICABLE MODEL Class Class Class Filter medium Air flow Model A B Quantity KAFJ301L KAFJ301L (each 2 filters) KAFJ371L The filter chamber is required when the long life filter will be installed Filter characteristics 3 Pressure loss KDDJ30L71 KDDJ30L140 (Pa) KDJ3705L280 Air volume (m 3 /min) 226 Systems Indoor Units

12 4 Control systems 4-1 Individual control systems WIRED REMOTE CONTROL BRC1D527 INFRARED REMOTE CONTROL Heat pump BRC4C62 Cooling only BRC4C64 SIMPLIFIED REMOTE CONTROL BRC2A51 REMOTE CONTROL FOR HOTEL USE BRC3A Centralised control systems CENTRALISED REMOTE CONTROL UNIFIED ON/OFF CONTROL SCHEDULE TIMER DCS302C51 DCS301B51 DST301B Others WIRING ADAPTER WIRING ADAPTER FOR ELECTRICAL APPENDICES (1) WIRING ADAPTER FOR ELECTRICAL APPENDICES (2) REMOTE SENSOR ELECTRICAL BOX WITH EARTH TERMINAL (3 BLOCKS) ELECTRICAL BOX WITH EARTH TERMINAL (2 BLOCKS) NOISE FILTER (FOR ELECTROMAGNETIC INTERFACE USE ONLY) EXTERNAL CONTROL ADAPTER FOR OUTDOOR UNITS (INSTALLATION ON INDOOR UNIT) KRP1B61 KRP2A61 KRP4A51 KRCS01-1 KJB311A KJB212A KEK26-1 DTA104A61 3D034600B 4 Systems Indoor Units 227

13 5 Capacity tables 5-1 Cooling capacity 5 Unit size Nominal capacity Outdoor air temp. TC: Total capacity;kw SHC: Sensible capacity;kw Indoor air temperature 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB 20.0DB 23.0DB 26.0DB 27.0DB 28.0DB 30.0DB 32.0DB CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC Systems Indoor Units

14 5 Capacity tables 5-1 Cooling capacity Unit size Nominal capacity Outdoor air temp. TC: Total capacity;kw SHC: Sensible capacity;kw Indoor air temperature 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB 20.0DB 23.0DB 26.0DB 27.0DB 28.0DB 30.0DB 32.0DB CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC Systems Indoor Units 229

15 5 Capacity tables 5-2 Heating capacity Outdoor Indoor air temperature CDB Unit Size Nominal capacity air temperature CDB CWB kw kw kw kw kw kw Systems Indoor Units

16 5 Capacity tables 5-2 Heating capacity Outdoor Indoor air temperature CDB Unit Size Nominal capacity air temperature CDB CWB kw kw kw kw kw kw Systems Indoor Units 231

17 6 Dimensions 6-1 Dimensional drawings FXMQ40,50MVE 22 - ø 4.7 hole 750 or more 700 or more 26 - ø 4.7 hole Inspection hole 450 or more 10 - ø 8 hole View Nr Part name Description 1 Liquid pipe connection ø 6.4 flare connection 2 Gas pipe connection ø 12.7 flare connection 3 Drain pipe connection VP25 (O.D. ø32, I.D. ø25) 4 Ground terminal M4 5 Switch box 6 Interunit wiring connection 7 Power supply connection 8 Air discharge flange 9 Air suction flange 10 Hook For M8~M10 Discharge side Suction side (Note. 2) 14 - ø 8 hole 1 Location of unit's name plate: switch box surface. 2 Mount the air filter at the suction side. (Select its colorimethod (gravity method) 50% or more). 3 Be sure to install a drain trap, as the drain outlet of the air-conditioner becomes negative pressure. 4 Be sure to install a drain trap for each unit separately, when you install a consolidated drain piping. 3D FXMQ63,80MVE 22 - ø 4.7 hole or more 700 or more 10 - ø 8 hole 26 - ø 4.7 hole Inspection hole 450 or more View Nr Part name Description 1 Liquid pipe connection ø 9.5 flare connection 2 Gas pipe connection ø 15.9 flare connection 3 Drain pipe connection VP25 (O.D. ø32, I.D. ø25) 4 Ground terminal M4 5 Switch box 6 Interunit wiring connection 7 Power supply connection 8 Air discharge flange 9 Air suction flange 10 Hook For M8~M10 Discharge side Suction side (Note. 2) 14 - ø 8 hole 1 Location of unit's name plate: switch box surface. 2 Mount the air filter at the suction side. (Select its colorimethod (gravity method) 50% or more). 3 Be sure to install a drain trap, as the drain outlet of the air-conditioner becomes negative pressure. 4 Be sure to install a drain trap for each unit separately, when you install a consolidated drain piping. 3D Systems Indoor Units

18 6 Dimensions 6-1 Dimensional drawings FXMQ100,125MVE 40 - ø 4.7 hole 1,100 or more 38 - ø 4.7 hole View 18 - ø 8 hole Nr Part name Description 1 Liquid pipe connection ø 9.5 flare connection 2 Gas pipe connection ø 15.9 flare connection 3 Drain pipe connection VP25 (O.D. ø32, I.D. ø25) 4 Ground terminal M4 5 Switch box 6 Interunit wiring connection 7 Power supply connection 8 Air discharge flange 9 Air suction flange 10 Hook For M8~M10 Discharge side 700 or more Inspection hole 450 or more Suction side (Note. 2) 18 - ø 8 hole 1 Location of unit's name plate: switch box surface. 2 Mount the air filter at the suction side. (Select its colorimethod (gravity method) 50% or more). 3 Be sure to install a drain trap, as the drain outlet of the air-conditioner becomes negative pressure. 4 Be sure to install a drain trap for each unit separately, when you install a consolidated drain piping. 3D FXMQ200,250MVE Piping size (field supply) 32 - ø 4.7 hole Model Gas Liquid FXMQ200MVE ø 19.1 attached piping ø 9.5 FXMQ250MVE ø 22.2 attached piping ø ø 4.7 hole 650 or more Discharge side View 1,100 or more Approx Inspection hole 600 or more Suction side (Note. 2) View Nr Part name Description 1 Liquid pipe connection Flare connection 2 Gas pipe connection Attendant piping connection 3 Ground terminal M5 (Inside switch box) 4 Switch box 5 Power supply wiring connection 6 Transmission wiring connection 7 Hook M10 8 Discharge companion flange 9 Suction flange 10 Attached piping Brazing 11 Name plate 12 Drain piping connection PS1B Internal thread VP25 (O.D. ø33.349, I.D. ø30.391) 13 Water supply port ø 8 hole 1 Location of unit s name plate: switch box surface. 2 Mount the air filter at the suction side. (Select its colorimethod (gravity method) 50% or more). 3D Systems Indoor Units 233

19 6 Dimensions 6-2 Dimensional drawings with drain pump kit FXMQ40-80MVE 740 (Suspending positions) 670 (Suspending positions) 750 or more Access panel 450 square or more Nr Part name Description 1 Ceiling mounted duct type s body 2 Drain pump kit 3 Drain pipe connection VP25 (O.D. ø32) 4 Water extracting hole 5 Drain connection pipe Attached to the drain pump kit 1 Be sure to provide an air filter in the suction air duct (with dust collection efficiency by more than 50% in the weight method.) 2 When the drain pump kit will be mounted, don't provide a trap in the drain pipe line. DU K FXMQ100,125MVE 1,060 (Suspending positions) 6 about (Suspending positions) 1,110 or more Nr Part name Description 1 Ceiling mounted duct type s body 2 Drain pump kit 3 Drain pipe connection VP25 (O.D. ø32) 4 Water extracting hole 5 Drain connection pipe Attached to the drain pump kit 1 Be sure to provide an air filter in the suction air duct (with dust collection efficiency by more than 50% in the weight method.) 2 When the drain pump kit will be mounted, don't provide a trap in the drain pipe line. DU D 234 Systems Indoor Units

20 6 Dimensions 6-2 Dimensional drawings with drain pump kit FXMQ200,250MVE 32 ø4.7 hole (Circumference) 32-ø7 hole (Circumference) A view 650 or more about or more Access panel 600 square (For indoor unit's filter) 16-ø8 hole Nr Part name Description 1 Ceiling mounted duct type s body 2 Filter chamber 3 High efficiency filter 4 Long life filter 5 Drain pump kit Built in a body 6 Drain piping connection VP25 (O.D. ø32, I.D.ø25) 7 Water inlet 8 Drain hose Attached to drain pump kit 3D011124B 6 Systems Indoor Units 235

21 6 Dimensions 6-3 Dimensional drawings with high efficiency filter/long life filter FXMQ40-80MVE 750 or more 430 or more Access panel 450 mm square or more Nr Part name Description 1 Ceiling mounted duct type s body 2 Filter chamber 3 High efficiency filter 4 Long life filter 1 Be sure to provide an air filter in the suction air duct (with dust collection efficiency by more than 50% in the weight method.) 2 Be sure to install a drain trap in the drain piping because the outlet of drain will fall to negative pressure. 3 When a centralised drain system will be applied, each indoor unit should have a drain trap individually. DU G FXMQ100,125MVE or more 750 or more Nr Part name Description 1 Ceiling mounted duct type s body 2 Filter chamber 3 High efficiency filter 4 Long life filter Access panel 450 mm square or more 1 Be sure to provide an air filter in the suction air duct (with dust collection efficiency by more than 50% in the weight method.) 2 Be sure to install a drain trap in the drain piping because the outlet of drain will fall to negative pressure. 3 When a centralised drain system will be applied, each indoor unit should have a drain trap individually. DU G 236 Systems Indoor Units

22 6 Dimensions 6-4 Centre of gravity FXMQ40-125MVE Model A B FXMQ40,50,63,80MVE FXMQ100,125MVE 1, D FXMQ200,250MVE Air outlet Air inlet 6 4D Systems Indoor Units 237

23 6 Dimensions 6-5 Bolt pitch FXMQ40-125MVE FXMQ200,250MVE Suspension bolt (x4) Suspension bolt (x4) 1,148 1,100 Air outlet Indoor unit Air inlet Indoor unit 1,296 1,380 Air outlet Air inlet Inspection hatch 450 Model A B FXMQ40MVE FXMQ50MVE FXMQ63MVE FXMQ80MVE FXMQ100MVE FXMQ125MVE 670 1, ,100 1,100 or more (service space) Approx. 150 mm Inspection hatch Install a canvas duct to the air discharge outlet and air inlet so that vibration from the machine body is not transmitted to the duct or ceiling. You should also apply acoustic (insulation material) to the inside of the duct, and vibration insulation rubber to the suspension bolts. 2 Install suspension bolts. Use bolts of 10 mm diameter. Install the equipment where supporting structures are strong enough to bear the equipment s weight. Use embedded inserts or anchor bolts with new buildings and hole-in-anchors with old buildings. 6 Ceiling slab Anchor Long nut or turn-buckle Suspension bolt Indoor unit NOTE 1 All the above parts are to be procured in the field. 3P Systems Indoor Units

24 7 Piping Diagram FXMQ-MVE Heat exchanger Gas pipe connection port Th3 Th1 Fan Th2 Liquid pipe connection port Filter Filter Electronic expansion valve Piping connection diameters Model Gas Liquid FXMQ40,50MVE ø12.7 ø6.4 FXMQ63,80,100,125MVE ø15.9 ø9.5 FXMQ200MVE ø19.1 ø9.5 FXMQ250MVE ø22.2 ø9.5 7 Th1 : Thermistor for suction air temperature Th2 : Thermistor for liquid line temperature Th3 : Thermistor for gas line temperature Check valve Flare connection Screw connection Flange connection Pinched pipe Spinned pipe 4D Systems Indoor Units 239

25 8 Wiring Diagrams FXMQ40-125MVE Power supply Electric parts box Note 4 Input from outside Note 3 Transmission wiring centralised remote control Note 2 Wired remote control (Optional accessory) Indoor unit Optional parts A1P Printed circuit board M1F Motor (indoor fan) M1P Motor (drain pump) A2P Terminal board Q1M Thermo switch M1F built-in only C1R Capacitor (M1F) R1T Thermistor (air) Wired remote control R2T R3T Thermistor (coil) SS1 Selector switch (main/sub) F1U Fuse (250V, 5A, ) type S1L Float switch R1T Thermistor (air) F1U Fuse (250V, 10A, ) type T1R Transformer ( V/22V) HAP Light emitting diode (service monitor-green) X1M Terminal strip (power) K1R-K3R Magnetic relay (M1F) X2M Terminal strip (control) Connector for optional parts KPR Magnetic relay (M1P) Y1E Electronic expansion valve X18A Connector (wiring adapter for electrical appendices) 8, : Terminal : Connector : Field wiring COLORS : BLK : Black PNK : Pink BLU : Blue RED : Red BRN : Brown WHT : White ORG : Orange YLW : Yellow 1 Use copper conductors only. 2 In case of high E.S.P. operation, change the wiring connection of X2A as shown. 3 In case of using centralised remote control, connect it to the unit in accordance with the attached instruction manual. 4 When connecting the input wires from outside, forced off or on/off control operation can be selected by remote control, more details can be found in the installation manual attached to the unit. 3D039620A 240 Systems Indoor Units

26 8 Wiring Diagrams FXMQ200,250MVE Power supply Electric parts box Note 5 Note 4 Input from outside Note 3 Transmission wiring Centralised remote control Wired remote control (Optional accessory) Indoor unit Optional parts A1P Printed circuit board Q1M Q2M Thermo switch (M1F 2F embedded) M1P Motor (drain pump) C1R 2R Capacitor (M1F 2F) R1T Thermistor (air) F1U Fuse (250V, 5A, ) R2T 3T Thermistor (coil) Wired remote control HAP Light emitting diode (service monitor-green) SS Selector switch (static pressure) SS1 Selector switch (main/sub) K1M Magnetic contactor (M1F 2F) T1R Transformer ( V/22V) R1T Thermistor (air) K2M Magnetic contactor (M1F 2F) X1M Terminal strip (power) K3M Magnetic contactor (M1F 2F) X2M-X3M Terminal strip Connector for optional parts K1R-K2R Magnetic relay (M1F 2F) X4M Terminal strip (control) KPR Magnetic relay (M1P) Y1E Electronic expansion valve X8A Connector (float switch) M1F 2F Motor (indoor fan) X18A Connector (wiring adapter for electrical appendices), : Terminal : Connector : Jumper connector : Field wiring COLORS : BLK : Black PNK : Pink BLU : Blue RED : Red BRN : Brown WHT : White ORG : Orange YLW : Yellow 8 1 In case of high E.S.P. operation, change the switch (SS) for H. 2 Use copper conductors only. 3 In case of using centralised remote control, connect it to the unit in accordance with the attached instruction manual. 4 When connecting the input wires from outside, forced off or on/off control operation can be selected by remote control. 5 In case of installing the drain pump, remove the jumper and execute the additional wiring for float switch (S1L). 3D039621A Systems Indoor Units 241

27 9 Sound level 9-1 Sound level data Model Sound pressure level - 220V H L Measuring location Sound power level FXMQ40MVE * FXMQ50MVE Discharge Suction * FXMQ63MVE Duct Duct * FXMQ80MVE * FXMQ100MVE * FXMQ125MVE * FXMQ200MVE * FXMQ250MVE * 1 Reference acoustic pressure 0 db = 20 Pa. 2 Measuring place: anechoic chamber 3 Operation noise differs with operation and ambient conditions. *Data were not available at the time of publication 9-2 Sound pressure spectrums 220V 240V FXMQ40,50MVE 4D034593A FXMQ63MVE 4D034594A FXMQ80,100MVE 4D034595A Octave band sound pressure level db (OdB = bar) Approximate threshold hearing for continuous noise Octave band sound pressure level db (OdB = bar) Approximate threshold hearing for continuous noise Octave band sound pressure level db (OdB = bar) Approximate threshold hearing for continuous noise 9 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) FXMQ125MVE 4D FXMQ200MVE 4D FXMQ250MVE 4D Octave band sound pressure level db (OdB = bar) Approximate threshold hearing for continuous noise Octave band sound pressure level db (OdB = bar) Approximate threshold hearing for continuous noise Octave band sound pressure level db (OdB = bar) Approximate threshold hearing for continuous noise Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) 242 Systems Indoor Units

28 10 Fan characteristics FXMQ40,50,63MVE 3D019610A FXMQ80MVE 3D018375A FXMQ100MVE 3D000067C 50 HZ 220V (mmh 2 0) External static pressure Upper limit of external static pressure (high ESP) (Pa) (mmh 2 0) Upper limit of external static pressure (standard ESP) Low (standard ESP) Low (high ESP) High (standard ESP) Upper limit of external static pressure (standard ESP) High (high ESP) Upper limit of external static pressure (high ESP) 50 HZ 220V (mmh 2 0) (Pa) (mmh 2 0) External static pressure Low (standard ESP) Upper limit of external static pressure (high ESP) Low (high ESP) Upper limit of external static pressure (standard ESP) High (standard ESP) High (high ESP) Lower limit of external static pressure (high ESP) Lower limit of external static pressure (standard ESP) 50 HZ 220V External static pressure Upper limit of external static pressure (high ESP) Low (high ESP) Upper limit of external static pressure (standard ESP) High (standard ESP) High (high ESP) Lower limit of external static pressure (standard ESP) Lower limit of external static pressure (high ESP) Low (standard ESP) (mmh 2 0) (Pa) Air flow (m 3 /min) (mmh 2 0) (mmh 2 0) (Pa) Air flow (m 3 /min) (mmh 2 0) Air flow (m 3 /min) FXMQ125MVE 3D000167C FXMQ200MVE 3D FXMQ250MVE 3D HZ 220V 50 HZ 220V (mmh 2 0) (Pa) (mmh 2 0) 50 HZ 220V (mmh 2 0) (Pa) (mmh 2 0) External static pressure Upper limit of external static pressure (standard ESP) Low (high ESP) Upper limit of external static pressure (standard ESP) High (high ESP) High (standerd ESP) Lower limit of external static pressure (standard ESP) Lower limit of external static pressure (high ESP) External static pressure Upper limit of ESP (high ESP) Low (high ESP) Upper limit of ESP (standard ESP) Low (standard ESP) Lower limit of ESP (standard ESP) High (high ESP) Lower limit of ESP (high ESP) High (standard ESP) External static pressure Upper limit of ESP (high ESP) Low (high ESP) Upper limit of ESP (standard ESP) Low (standard ESP) Lower limit of ESP (standard ESP) High (high ESP) Lower limit of ESP (high ESP) High (standard ESP) (mmh 2 0) (Pa) Air flow (m 3 /min) (mmh 2 0) 10 Low (standard ESP) (mmh 2 0) (Pa) Air flow (m 3 /min) (mmh 2 0) Air flow (m 3 /min) 1 The remote control can be used to switch between high and low. 2 The air flow is set to standard before leaving the factory. It is possible to switch between standard ESP and high ESP by changing the terminals in the indoor unit electrical box. Systems Indoor Units 243

29 11 Installation 11-1 Installation example Air outlet Suction grille Remote control 11-2 Service space 1. Select an installation site: Where the following conditions are fulfilled and that meets with your customer's approval. Where sufficient clearance for maintenance and service can be ensured. Where optimum air distribution can be ensured. FXMQ40-125MVE FXMQ200,250MVE 470 Min. 450 Min. 700 (service space) Model FXMQ40MVE FXMQ50MVE FXMQ63MVE FXMQ80MVE FXMQ100MVE FXMQ125MVE A 750 1,100 Min. 650 (service space) NOTE 1 Above figures mean minimum values. 3P Where nothing blocks the air passage. Where condensation can be properly drained. Where piping between indoor and outdoor units is possible within the allowable limit (Refer to the installation manual of the outdoor unit.) If supporting structural members are not strong enough to take the unit's weight, the unit could fall out of place and cause serious injury. Keep the indoor and outdoor units, power cable and transmission wiring, at least 1 m from TVs and radios, to prevent distorted pictures and static. (Depending on the type and source of the electrical waves, static may be heard even when more than 1 m away.) 2. Check whether the place is strong enough to bear the weight of the unit or not. If there is a risk, reinforce the place before installing the unit. 244 Systems Indoor Units

30 11 Installation 11-3 Drain piping Rig the drain pipe as shown below and take measures against condensation. Improperly rigged piping could lead to leaks and eventually wet furniture and belongings. Insulate the drain hose inside the buildings 1. Install the drain pipes FXMQ40-125MVE Keep piping as short as possible and slope it downwards so that air does not remain trapped inside the pipe. Attached drain hose Keep pipe size equal to or bigger than that of the connecting pipe (Vinyl pipe of 25 mm I.D. and 32 mm E.D.). Bottom of unit Use the attached drain hose and clamp. Tighten the clamp firmly. 5 cm or more Insulate the clamp metal with the attached sealing pad. There is negative pressure inside the unit relative to atmospheric pressure when the unit is running, so be sure to provide drain trap on the drain outlet. (See the figure) In order to prevent foreign matters from building up inside the piping, you should avoid curves as much as possible, and arrange so the trap can be cleaned. Clamp metal (Attached with unit) Large sealing pad (Attached with unit) Clamp metal 5 cm or more NOTE 1 If installing centralised drain piping, install according to the following right figure. (Install a drain trap for each indoor unit.) 4 mm or less Drain hose Drain hose 100 mm or more FXMQ MVE A drain pipe need not be installed. The diameter of the piping is the same as that of the connecting pipe (PS1B), and should be kept equal to or bigger than that of the connecting pipe. 2. After piping work is finished, check if drainage flows smoothly. 11 Systems Indoor Units 245

31 Systems ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin units comply with the European regulations that guarantee the safety of the product. VRV products are not within the scope of the Eurovent certification programme. Daikin equipment is designed for comfort applications. For use in other applications, please contact your local Daikin representative. Specifications are subject to change without prior notice Zandvoordestraat 300 B-8400 Ostend - Belgium EEDE04-2/2A 10/2004 Prepared in Belgium by Lannoo

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units t i t l r - I Features s e Cs m B ne d E Ue V s 7 ya P os e oc Q dvn S nr ox VF C Reduction of power consumption of 20% (compared to FXSQ-M8 series) through use of new DC fan Improved comfort thanks to

More information

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems Indoor Units

More information

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................

More information

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

Split-Sky Air FDYP-B7 Concealed Ceiling Unit TECHNICAL DATA Split-Sky Air FDYP-B7 Concealed Ceiling Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the

More information

Split-Sky Air FAYP-B Wall Mounted Unit

Split-Sky Air FAYP-B Wall Mounted Unit TECHNICAL DATA Split-Sky Air FAYP-B Wall Mounted Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential

More information

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air EEDEN08-00 technical data FDQ-B8V3B9 air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led

More information

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air technical data RXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human

More information

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................

More information

technical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air

technical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air technical data FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help

More information

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air technical data MA-GZ7 Multi Model Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect human health

More information

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air technical data RKS-C RKS-B Pair Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help

More information

technical data air conditioning systems MXS-B Multi Application Split Sky Air

technical data air conditioning systems MXS-B Multi Application Split Sky Air technical data MXS-B Multi Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment

More information

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8 Air Conditioners Technical Data Individual branch selector for VRV heat recovery (Individual BS box) EEDEN11-200 BSVQ100-250P8 Air Conditioners Technical Data Individual branch selector for VRV heat recovery

More information

Split-Sky Air RMX-JZ Super Multi Plus

Split-Sky Air RMX-JZ Super Multi Plus TECHNICAL DATA Split-Sky Air RMX-JZ Super Multi Plus Split Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential

More information

Outdoor Units R-410A ARX-GV1B

Outdoor Units R-410A ARX-GV1B Outdoor Units R-40A ARX-GVB t A i n y U k BS r o AV t o0g i d- lt4x pur- SRAO 2 Specifications Outdoor Units R-40A ARX-GVB 2- NOMINAL CAPACITY AND NOMINAL INPUT ARX20GVB ARX25GVB ARX5GVB For combination

More information

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air technical data FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette Multi (950mm Split Heat x 950mm) Pump (edited) air conditioning systems Split Sky Air Outdoor Units R40A MXS-DAVMB_E2VB_E7VB Features V i

More information

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series Inverter cooling only / heat pump series RSX(Y)P5,8,10K7W1 RSX(Y)P-K7W1 1 Inverter cooling only / heat pump series 1 1 Specifications

More information

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air technical data RYP-L7/B7 Pair Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the

More information

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air technical data RQ-B7 Pair/Twin/Triple/Double Twin Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect

More information

Air Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB

Air Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB Air Conditioning Technical Data Heat reclaim ventilation EEDEN14-205 VAM-FA/FB Heat reclaim ventilation VAM-FA/FB VAM-FA/FB 1 Features............................................................. 2 2 Specifications.......................................................

More information

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV Air Conditioning Technical Data Wall mounted unit EEDEN15-100 FTX-GV TABLE OF CONTENTS FTX-GV 1 Features............................................................. 2 2 Specifications.......................................................

More information

Technical Service Manual

Technical Service Manual Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........

More information

Low Static Pressure Duct(V shape evaporator)

Low Static Pressure Duct(V shape evaporator) Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...

More information

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping

More information

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit E10-1 High Static Duct 8, 10HP Digital Inverter Engineering Data Book Indoor Unit RAV-SM2242DT-E RAV-SM2802DT-E RAV-SM2242DT-TR RAV-SM2802DT-TR Outdoor Unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents 1 Specifications..............................................................

More information

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application TECHNICAL DATA Split-Sky Air RP-B7 Twin/Triple/Double Twin Application Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment

More information

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit E0--2 High Static Duct 8, 0HP Digital Inverter Engineering Data Book Indoor Unit RAV-SM2242DT-E RAV-SM2802DT-E RAV-SM2242DT-TR RAV-SM2802DT-TR Outdoor Unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents Specifications..............................................................

More information

Fan Coil Units. Technical Data

Fan Coil Units. Technical Data Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Table of Contents Table of Contents 3 Round Flow Cassette...

More information

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams... MCAC-VTSM-2013-08 1. Features... 264 2. Specifications... 265 3. Dimensions... 268 4. Service Spaces... 272 5. Piping Diagrams... 273 6. Wiring Diagrams... 274 7. Capacity Tables... 276 8. Electrical Characteristics...

More information

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units i r -t i l t - Outdoor Units R-40A RZQ7-40C7VB Features V 7n y CU k 0 S 4 oa o 0 d 7 4Q puz RO S Outdoor units for pair, twin, triple, double twin application The Sky Air Inverter is developed for use

More information

VHIA High-Static Ducted Indoor Units - 60HZ

VHIA High-Static Ducted Indoor Units - 60HZ PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage

More information

Low Static Pressure Duct (V shape evaporator)

Low Static Pressure Duct (V shape evaporator) MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...

More information

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features 19 Series High-Efficiency Wall-Mounted Ductless systems Performance: Up to 19 SEER 12.5 EER 9.0 HSPF Product Features Inverter Compressor 208/230/1 Power Supply Cooling Range: -4-115 F (with optional wind

More information

Compact Four-way Cassette Type

Compact Four-way Cassette Type 1. Features... 34 2. Specifications... 35 3. Dimensions... 37 4. Service Spaces... 38 5. Piping Diagrams (EXV beside)... 39 6. Wiring Diagrams... 40 7. Capacity Tables... 41 8. Electrical Characteristics...

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-90EB RO-90EPB C O N T E N T S SPECIFICATIONS... OUTLINE AND DIMENSIONS... CIRCUIT DIAGRAM...5 REFRIGERANT SYSTEM DIAGRAM...6

More information

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Split Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Indoor Unit FTXC-A TABLE OF CONTENTS FTXC-A 1 Features.............................................................

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

Service manual MIV V4+ Indoor units

Service manual MIV V4+ Indoor units Service manual MIV V4+ Indoor units Floor Standing MVF22A-VA1 MVF28A-VA1 MVF36A-VA1 MV5A-VA1 MVF56A-VA1 MVF71A-VA1 MVF80A-VA1 MVB22A-VA1 MVB28A-VA1 MVB36A-VA1 MVB45A-VA1 MVB56A-VA1 MVB71A-VA1 MVB80A-VA1

More information

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs

More information

Air Conditioners. Technical Data UATYQ-CY1

Air Conditioners. Technical Data UATYQ-CY1 Air Conditioners Technical Data R o o f t o p s E E D E N 2-2 0 UATYQ-CY Air Conditioners Technical Data R o o f t o p s E E D E N 2-2 0 UATYQ-CY Single Unit Rooftop UATYQ-CY TABLE OF CONTENTS UATYQ-CY

More information

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2013.12 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT Fan Coil Units Technical Data Conceiled ceiling unit ECDEN10-400 FWB-BT Fan Coil Units Technical Data Conceiled ceiling unit ECDEN10-400 FWB-BT TABLE OF CONTENTS FWB-BT 1 Features.............................................................

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E R407C TECHNICAL MANUAL Split Systems Air Conditioner Ducted Blower D & E Series FDMP-D, FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E series Cooling only & Heatpump [50Hz] Table of Contents Table of Contents

More information

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 2-8 GENERAL DATA 2.3. INVERTER SERIES 2.3.1. INVERTER (RAS-25YHA2/35YHA3/50YHA2/60YHA2/70YHA2/80YHA2) Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 Power Supply From Outdoor Unit

More information

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air

More information

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series VRF Indoor Unit 50Hz Type: Wall Mounted M Series Wall Mounted S Series Contents 01 Wall Mounted M Series 20 Wall Mounted S Series MCAC-VTSM-2016-05 Wall Mounted M Series Wall Mounted M Series 1. Features...

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

BAC / BHC Product Specifications

BAC / BHC Product Specifications COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

MSP Duct S Specifications

MSP Duct S Specifications MSP Duct S Specifications Model Name AM022FNMDEH AM028FNMDEH AM036HNMPKH AM045HNMPKH AM056HNMPKH Capacity *2) 2.2 2.8 3.6 4.5 5.6 *3) 2.5 3.2 4.0 5.0 6.3 Perfomance (Total) *5) kw 1.8 2.3 2.9 3.7 4.6 VRF

More information

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,

More information

CHILLED WATER FAN-COIL UNITS

CHILLED WATER FAN-COIL UNITS 40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in

More information

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz] R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS 550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated

More information

WCA4**4. Product Specifications

WCA4**4. Product Specifications WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Indoor Console Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Black Display Functional art, the touch screen display is elegant

More information

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump)

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) PRK 00-04 PREVIEW System OZONE FRIENDLY R-407C Series Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) 3DUW#4 2XWGRRU#8QLWV 111111111111111111111111111111111111111111111111111111111111111111111

More information

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without

More information

PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A PCXAU161 VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ Heat Pump 5/6 Hz R-1A An industry first, the VRV air handling unit has been designed and engineered

More information

High Wall Type ( 2 Series )

High Wall Type ( 2 Series ) Jan.05' Engineering Data High Wall Type ( 2 Series ) Indoor Unit MMK-AP0072H MMK-AP0092H MMK-AP0122H 1. Equipments 2. Technical Specifications 3. Dimensional Drawing 4. Wiring Diagram 5. Refrigerant Cycle

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR:

More information

Air Conditioning. Technical Data EEDEN RXZ-N

Air Conditioning. Technical Data EEDEN RXZ-N Air Conditioning Technical Data EEDEN14-100 RXZ-N TABLE OF CONTENTS RXZ-N 1 Features............................................................. 2 2 Specifications.......................................................

More information

Tons BTU/h S.E.E.R* E.E.R** HSPF

Tons BTU/h S.E.E.R* E.E.R** HSPF SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum

More information

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425) ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV

More information

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS.

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS. SPLIT-TYPE, AIR CONDITIONERS Revision A: MU-A2YV - E can be connected to MCF-A2WV - E. Please void OB330. SERVICE MANUAL Wireless type Models E MU-A07YV - E MU-A09YV - MU-A2YV - E HFC utilized R40A No.

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

SUNLINE 2000 (WORLD 50 HZ)

SUNLINE 2000 (WORLD 50 HZ) 530.26-TG1YI (298) SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS D3CE 036, 048, 060 & 076 D5CG 036, 048, 060 & 076 3, 4, 5 AND 6 NOMINAL TONS SHOWN SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION YORK Sunline 2000

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU SINGLE Technical Data Book Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU History Version Modification Date Remark Ver.1.0 Release SINGLE Big

More information

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors

More information

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

SERVICE MANUAL OUTDOOR UNIT. No. OB386

SERVICE MANUAL OUTDOOR UNIT. No. OB386 SPLIT-TYPE AIR CONDITIONERS Revision D: MU-A20VB- E and MU-A5VB- E have been added. Please void OB86 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A No. OB86 REVISED EDITION-D Models MU-A20VB-

More information

Four-way Cassette Type

Four-way Cassette Type Four-way Cassette Type Four-way Cassette Type 1. Features... 9 2. Specifications... 12 3. Dimensions... 17 4. Service Space... 18 5. Wiring Diagrams... 19 6. Capacity Tables... 21 7. Electric Characteristics...

More information

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors

More information

FFQN-C, FCRN-E, FFRN-C

FFQN-C, FCRN-E, FFRN-C R410A TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FCQN-E, FFQN-C, FCRN-E, FFRN-C Cooling only & Heatpump [50Hz] DAIKIN_FFRN.indb i 12/27/2012 9:28:06 AM DAIKIN_FFRN.indb ii

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS ACWL Series ACWL0 thru ACWL4 00 CFM thru 400 CFM GE_ACWL_series.indd 3// : PM CONTENTS Model decoding 3 Unit features 3 Standard specifications 3-4

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with

More information

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low

More information

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E SPLIT TYPE AIR CONDITIONER CASSETTE type Models Indoor unit Outdoor unit C24YE MC24Y3E MR24Y3E1 SPECIFICATIONS TYPE COOL & HEAT INDOOR UNIT MC24Y3E OUTDOOR UNIT MR24Y3E1 COOLING CAPACITY 23,500-22,500

More information