Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor
|
|
- Caitlin Jefferson
- 6 years ago
- Views:
Transcription
1 Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series covers a wide range of external static pressure from 0 Pa up to 00 Pa. The units offer excellent features and benefits in terms of the following: compact size, low initial cost, super low noise operation, ease of installation and ease of maintenance making them ideal for or heating a wide range of applications including apartments, banks, hotels, shopping malls, show rooms, air ports, stores, museums, high rise buildings, schools, office buildings and many other applications. Casing CR-A casing provides excellent inherent strength, stability and air tightness. The casing is fabricated from heavy gauge hot dipped galvanized steel sheet metal (Electrostatic painted casing is available upon request). The casing is insulated with 5 mm thick closed cell insulation (other thickness are available upon request) forming a rigid enclosure with high acoustic attenuation, high thermal insulation and superior air tightness. Sufficient strengthening forms and folds are incorporated to give a robust vibration free assembly. All units are supplied with a collar for direct connection with the supply and return air duct. Coil/Drain pan Chilled water coils are constructed of 3/8 inch copper tubes, mechanically bonded to high efficiency corrugated aluminum fins. Standard coils are three rows deep with an option of two or four rows depending on the required specifications. All coils are factory tested at 30-atmosphere pressure according to the international standards and are sealed with a quality pass label and a traceable serial number before being installed in the units. Optional fin materials are available upon special request, including golden plated, vinyl-coated aluminum and copper. The coil matrix is held firmly within a heavy gauge galvanized framework. The coil assembly complete with brass distributors and a manual air vent is located above a full width condensate tray which covers both the entire coil face area and the coil headers, return bends, distributors and control valves. The condensate tray (drain pan) is constructed of corrosion resistant electrostatic painted galvanized steel sheet metal (other construction materials are available upon special request, including aluminum and stainless steel) and externally insulated by 5mm thick closed cell insulation (other thickness are available upon request). The drain pan is internally sloped for a smooth, clogging free drainage mechanism. The drain outlet is threaded and plugged with a plastic cap for simple on-site connection. Water connections are standardized on the right hand side of the coil when facing the airflow with male threaded header of ¾ inch.the coil can be supplied on either sides according to the customer requirements and can be turned on site for more flexibility. Fan/Motor Direct drive fans are centrifugal, forward curved with double-width wheels. The fan housing is constructed of heavy gauge galvanized steel. The fan wheel is constructed of high tensile aluminum or heavy gauge galvanized steel. The fan wheel and housing are designed to minimize air borne noise levels. All fan wheels are individually tested and precision balanced statically and dynamically and keyed to the shaft. Fan motors are single or double shaft, class B insulation (class F is available upon request), resilient-mounted, three or five speeds tapped wound with thermal overload protection and a permanent split type capacitor. Three speeds are pre-wired as standard. All motors have long life self lubricated bearings of the sleeve or ball bearing types. All wiring is made at 0V, single phase and 50HZ. Motors are suitable for 50Hz, single-phase with 0/40, operating voltages. 60Hz, single-phase motors are also available as an option with 08/0V operating voltages. Filter Two filter options are available for the CR-A series including washable synthetic and aluminum filters. The first option is filter cells with filter media composed of polyester A40. The filter frame is constructed of corrosion resistant galvanized steel sheets. The synthetic filter is flame resistant according to F-Din classification. The second option is regenerable filter cells with multi layer metallic media composed of aluminum. The filter frame is constructed of corrosion resistant galvanized steel sheets. The average gravimetric efficiency is 75% with EN 779 G classification. The aluminum filter is fireproof. Either options come with mm filter thickness as standard. (Other media thickness is available upon request) The filter section is designed to easily withdraw the filter panels for maintenance or renewal when required. Options & Accessories - Electrostatic painted casing - Aluminum drain pan - Electric Heaters - Stainless steel drain pan - or 4 rows chilled/hot water coils - Vertical units - 4 Pipes System (3 Rows + Row heating) - Dampers - DX coils - Grills - Copper tubes / copper fins coil - Wall mounted three speed switch
2 High Speed (3 Rows Cooling Coil) Model CR-0A CR-04A CR-06A CR-08A CR-0A CR-A CR-6A CR-8A T.H. Kw E.S.P. 0 Pa S.H. Kw L.A.T. C L.A.R.H. % W.F.L. L/Hr W.P.D. Kpa T.H. Kw E.S.P. 5 Pa S.H. Kw L.A.T. C L.A.R.H. % W.F.L. L/Hr W.P.D. Kpa T.H. Kw S.H. Kw L.A.T. C L.A.R.H. % W.F.L. L/Hr W.P.D. Kpa Cooling Coil Row/Fin Pitch Tube Diameter mm 3/. 3/8 Inch Copper Smooth Tube FAN Type No. of Fans Double Inlet Centrifugal Fan No. of Motors FAN MOTOR Supply Power Output Power Watt //50 V/Ph/Hz Full load Amp Filter Size W x H mm 600x0 740x0 05x0 90x60 90x300 75x300 Dimensions L x W x H mm 800x539x5 940x539x70 5x539x70 390x539x8 390x565x33 475x565x33 Standard Electric Heater Watt Net Wight Kg Inlet&Outlet Pipe Connection inch 3/4 Drain Pipe Connection inch / Global Sound Power Level 5 Speeds T.H. : Total Heat Load Capacity. S.H. : Sensible Heat Load Capacity. L.A.T. : Leaving Air Temperature. L.A.R.H. : Leaving Air Relative Humidity. W.P.D. : Water Pressure Drop. We Reserve the right to make any changes in the specifications and performance data. - Total & Sensible Cooling Capacities are based on Chilled Water Entering / leaving Temperatures 7 o C / o C. - * Sound Power Levels are for basic Fan Coil Units according to Eurovent standard 8/ & ISO 374.
3 Medium Speed (3 Rows Cooling Coil) Model CR-0A CR-04A CR-06A CR-08A CR-0A CR-A CR-6A CR-8A T.H. Kw E.S.P. 0 Pa S.H. Kw L.A.T. C L.A.R.H. % W.F.L. L/Hr W.P.D. Kpa T.H. Kw E.S.P. 5 Pa S.H. Kw L.A.T. C L.A.R.H. % W.F.L. L/Hr W.P.D. Kpa T.H. Kw S.H. Kw L.A.T. C L.A.R.H. % W.F.L. L/Hr W.P.D. Kpa Air Flow Selection 3 Rows Coil Model CR-0A CR-04A CR-06A CR-08A CR-0A CR-A CR-6A CR-8A Air Flow External Static Pressure (Pa) Speed
4 High Speed (4 Rows Cooling Coil) Model CR-0A CR-04A CR-06A CR-08A CR-0A CR-A CR-6A CR-8A T.H. Kw E.S.P. 0 Pa S.H. Kw L.A.T. C L.A.R.H. % W.F.L. L/Hr W.P.D. Kpa T.H. Kw E.S.P. 5 Pa S.H. Kw L.A.T. C L.A.R.H. % W.F.L. L/Hr W.P.D. Kpa T.H. Kw S.H. Kw L.A.T. C L.A.R.H. % W.F.L. L/Hr W.P.D. Kpa Cooling Coil Row/Fin Pitch Tube Diameter mm 4/. 3/8 Inch Copper Smooth Tube FAN Type Double Inlet Centrifugal Fan No. of Fans No. of Motors FAN MOTOR Supply Power Output Power Watt 0-40//50 V/Ph/Hz Full load Amp Filter Size W x H mm 600x0 740x0 05x0 90x60 90x300 75x300 Dimensions L x W x H mm 800x539x5 940x539x70 5x539x70 390x539x8 390x565x33 475x565x33 Standard Electric Heater Watt Net Wight Kg Inlet&Outlet Pipe Connection inch 3/4 Drain Pipe Connection inch / Global Sound Power Level 5 Speeds T.H. : Total Heat Load Capacity. S.H. : Sensible Heat Load Capacity. L.A.T. : Leaving Air Temperature. L.A.R.H. : Leaving Air Relative Humidity. W.P.D. : Water Pressure Drop. We Reserve the right to make any changes in the specifications and performance data. - Total & Sensible Cooling Capacities are based on Chilled Water Entering / leaving Temperatures 7 o C / o C. - * Sound Power Levels are for basic Fan Coil Units according to Eurovent standard 8/ & ISO
5 Medium Speed (4 Rows Cooling Coil) Model CR-0A CR-04A CR-06A CR-08A CR-0A CR-A CR-6A CR-8A T.H. Kw E.S.P. 0 Pa S.H. Kw L.A.T. C L.A.R.H. % W.F.L. L/Hr W.P.D. Kpa T.H. Kw E.S.P. 5 Pa S.H. Kw L.A.T. C L.A.R.H. % W.F.L. L/Hr W.P.D. Kpa T.H. Kw S.H. Kw L.A.T. C L.A.R.H. % W.F.L. L/Hr W.P.D. Kpa Air Flow Selection 4 Rows Coil Model CR-0A CR-04A CR-06A CR-08A CR-0A CR-A CR-6A CR-8A Air Flow External Static Pressure (Pa) Speed
6 Guide Specifications D Air Vent Water out Water in H B F Return Air I Supply Air 6 D D 90 A Return Duct Collar 7 mm. 7 E Supply Duct Collar 4 mm. FRONT VIEW SIDE VIEW M Electric Box N 45 6 C T 03 o 65 P TOP VIEW Model A B C D E F I H M N O P T CR-0A CR-04A CR-06A CR-08A CR-0A CR-A CR-6A CR-8A *All Dimensions are in ( mm ) Extended Drain Pan Insulation Unit Mounting Fan Coil Filter Coil Header & Cover Guard Electric Box 6
42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option
42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater
More informationDECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS
DECORATIVE FAN COIL SPECIFICATIONS UNIT CABINET Single skin or double skin casing (inner perforated sheet or flat sheet) made of powder coated galvanized steel assembled in aluminum extrusion profiles,
More informationChiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial
Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil
More informationLOW STATIC FAN COIL UNITS District Cooling Chilled Water Application
STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications
More informationThe World Leading Air-conditioning Company
The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040
More informationAddress: VTS Clima L.L.C.
Address: VTS Clima L.L.C. Business Bay, Churchill Tower, Office 2409, P.O.Box#76849 Dubai, UAE phone: +971 (4) 443 91 20 fax: +971 (4) 443 96 20 e-mail: dubai@vtsgroup.com www.uae.vtsgroup.com Index VTS
More informationCHILLED WATER FAN-COIL UNITS
40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in
More information42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application
42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT MODEL NUMBER NOMENCLATURE 4 2 C E T 0 0 3 4 7 0 1 2 5 42 series CISB Code
More informationMAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional
Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed
More informationFan Coil Units POWERED BY KLIMAK ITALY
Fan Coil Units POWERED BY KLIMAK ITALY Index Chilled Water Fan Coil Unit Decorative Fan Coil... Concealed Ducted Fan Coil Unit (Low ESP)...11 Concealed Ducted Fan Coil Unit (Medium ESP)...1 Concealed
More informationDAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)
Engineering Data ED-FWW-201501 Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Models: FWW200 FWW300 FWW400 FWW600 FWW800 FWW1000 FWW1200 FWW1400 FWW1600 FWW1800 Air Flow: 360-3020m 3 /h DAIKIN
More informationROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh
ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered
More informationTechnical Sales Guide # 040 YDFC 0 1 Page 2
17-18 Technical Sales Guide # 040 YDFC 0 1 Page 2 Technical Sales Guide # 040 YDFC 0 1 Page 3 York China Fan Coil Unit Model Type ST - Standard DC - District Cooling Number of rows 3: 3 Rows 4: 4 Rows
More informationFans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL Centrifugal fan coil units SYSCOIL Fan coil units Compact, slim fan coil units. Available
More informationFan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4
Fan coil units HFCE, HFXE, VFCE, VFXE series Sizes 03 to 20-300 to 3400 m3/h 2012 Trane Contents Features and Benefits 4 Model Nomenclature 5 Performance Data 7 Capacities 9 Dimensional data 19 Typical
More informationEngineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h
Engineering Data Manual New : available with EC motor VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 800 to 4650 m 3 /h General Characteristics Presentation On model VH 07, coils have 4
More informationChilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.
Chilled Water FCU A Series 3-25 CFM Horizontal Fan Coil 5hz www.windind.com CONTENTS GENERAL CONSTRUCTION... 3 MODEL NUMBER NOMENCLA TURE... 4 DIMENSIONS... 5 FAN PERFORMANCE DATA... 7 GENERAL SPECIFICATIONS...
More informationTECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS
Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal
More informationGENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS
GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS ACWL Series ACWL0 thru ACWL4 00 CFM thru 400 CFM GE_ACWL_series.indd 3// : PM CONTENTS Model decoding 3 Unit features 3 Standard specifications 3-4
More informationDuctable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03
Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet
More informationHigh Static Pressure Duct Fan Coil Unit
MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4
More informationCeiling Concealed Chilled Water Fan Coil Unit
Technical Manual MODELS: ACW200 ACW300 ACW400 ACW600 ACW800 ACW1000 ACW1200 Air Flow: 112~2040 m 3 /h ACW - C/F/H - 2009-001 Ceiling Concealed Chilled Water Fan Coil Unit Contents Nomenclature... 2 Features...
More information42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM
42CLS-W Series Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM World's No.1 Air Conditioning Expert www.carrier.co.th 42CLS-W Series Furred-in ceiling model 400-0 cfm The low silhouette
More informationCarisma The Ultra Quiet Fan Coil
Carisma The Ultra Quiet Fan Coil Air Conditioning Carisma / CRR Fan Coil Units Quality management systems SO 900 Cert. n 0545/4 www.euroventcertification.com www.certiflash.com CONTENTS Construction ()
More informationINTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter
INTRODUCTION GENERL DESCRIPTION Ducted Direct Drive Fan Coil ir Conditioners are designed to fulfill the air conditioning requirements of today s living. These requirements include dependable trouble-free
More informationHBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR
PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed
More informationSBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL
SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES
More informationCENTRIFUGAL FAN COIL UNIT VCE
CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical
More informationMH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil
MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000
More informationWater Source Heat Pump P 34 P 35. Features. Optional. Instruction of model. Water-Cooled Screw Chiller
Source Heat Pump -Cooled Screw Chiller R410a Product type LSSR10 LSSR14 LSSR16 LSSR20 LSSR28 Rated cooling capacity kw/btu/h 10.5 35836.5 14 47782 15.5 52902 21 71673 28 95564 Rated heating capacity kw/btu/h
More informationNEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only
NEW Wall controls Fan Coil Units www.euroventcertification.com www.certiflash.com Technical Guide for internal distribution only CONTENTS Construction Page 4 s Page 5 Dimension, Weight, Water content Page
More informationHighline 260i EC Waterside Fan Coil Unit
Features: Electronically Commutated (EC) fan motor Specific Fan Power of 0.16 to 0.34 at NR Insignificant fan heat gain Designed to operate below NR at External Static Pressures of up to 50Pa Variable
More informationFCVC Series VERTICAL FAN COILS
VERTICAL FAN COILS The FCVC is designed for concealed, wall mounted installations with flexible heating/ cooling loads and minimal duct requirements. With a variety of options, such as fiber free insulation,
More information42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001
42CHS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM QMS 001 World's No.1 Air Conditioning Expert www.carrier.co.th 42CHS-W Series Furred-in ceiling model 400-2000
More informationBUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC
BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC Product Introduction INTRODUCTION Johnson Controls YORK YECFC fan coil units are high efficiency, low profile,
More informationCMTE. Tangential Fan Coil Series with Electronic Controlled Motor
Tangential Fan Coil Series with Electronic Controlled Motor Designed by Very Low Electric Energy Consumption High Efficiency Extremely Low Noise Level Infra Red Remote Control Step-less Fan Speed Control
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationAIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements
AIR HANDLING UNITS Customisable modular air handling unit, designed and built to suit your project requirements PacAir Modular Air Handling Units by are customisable, designed and built for n, New Zealand
More informationUTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management
Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and
More informationMODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING
MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.
More informationVLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw
Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension
More informationVERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT
VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.
More information48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH
48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position
More informationCert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE
Cert. n 0545 www.euroventcertification.com Carisma Fan Coil Unit The Ultra Quiet Fan Coil TECHNCAL GUDE Carisma CONTENTS Construction Page 4 s Page 5 Dimension, Weight, Water content Page 6 EUROENT certification
More informationOcelot vertical fan coil unit
Ocelot vertical fan coil unit 250mm Deep vertical Waterside control Cased unit DUNHAM BUSH OCELOT VERTICAL CASED FAN COIL UNIT The Dunham Bush Ocelot fan coil unit is a fully cased vertical unit suitable
More informationChassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A
Chassis panelwork is all In House manufactured from nominally 1.2mm Galvanised steel. Where at all possible, flanges are formed inward facing to prevent exposure to bare metal edges. Sufficient forms and
More informationCommercial Blower Coil Air Handlers
Commercial Blower Coil Air Handlers MODEL : BDH(V)B - 048, 065, 080 7400 CMH - 14300 CMH 30 kw - 125 kw BCXB-PRC001-E4 Contents Model Number Description General Specification Standard Features Unit Configuration
More informationRBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL
RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBVS RBVR RBVC www.superiorrex.com RBV Series: LOW POWER CONSUMPTION, ACCESSIBLE AND FLEXIBLE Owners Owners can choose between a standard or elevated
More informationHIGH STATIC FAN COIL UNITS
STATIC FAN COI UNITS District Cooling Chilled Water Application TECNICA CATAOGUE (DUCTED TYPE) GFC - D SERIES COOING CAPACITY RANGE: 10,407 TO 66,329 BTU/R CASSIFIED INSUATION & FITER EDIA GFC-D-TC-10-13
More informationProduct Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP
FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low
More informationPHCD-Series. Catalog
PCD-Series Catalog odel: PCD Introduction PCD fan coil unit is designed for a fully concealed ceiling installation. The external static pressure(esp) is up to 75Pa. Owing to its low static and low noise,
More informationComplete HVAC Capability
Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option
More informationYEAR-ROUND AIR CONDITIONING Our Deluxe-Aire units are ideally suited to provide heating, cooling and air filtration for areas where it is not
YEAR-ROUND AIR CONDITIONING Our Deluxe-Aire units are ideally suited to provide heating, cooling and air filtration for areas where it is not feasible to provide a large central system and run duct work
More informationHBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR
PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed
More informationAHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology
HANDLERS LTD AHPHX Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since
More informationThe Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat
More informationAHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology
HANDLERS LTD AHTW Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since
More informationTable of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10
Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19
More informationDIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE
DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.
More informationCHILLED WATER DUCTED FAN COIL
SD CHILLED WATER DUCTED AN A Series B Series (Double Skin) General abricated with a rigid galvanized steel casing. The DIDW centrifugal fans have balanced, galvanized steel, and forward curved blades.
More informationSentinel D-Box Twin Fan
Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc
More informationFN Fan-Coil Units High-Performance, Horizontal
FN Fan-Coil Units High-Performance, Horizontal Model FNX Exposed-Cabinet Dimensional Data Notes: 1. All dimensions are in inches [mm] and are +/- 1/8" [3 mm]. Metric values are soft conversions. 2. See
More informationPVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology
AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May
More informationFeatures: Concealed installation. Compact design. Available in electric, LPHW or ambient.
Features: Concealed installation. Compact design. Available in electric, LPHW or ambient. Grille can be supplied in a large range of colours. Energy saving controls option available. Application The Diffusion
More informationModular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016
Modular Air Handling U n i t R a n g e Up to 3,500 Litres / sec Low profile & Plant room application AirDesign 2015 AirDesign 2016 Second Edition Draft Version A-. Air Design is a proud Australian based
More informationCFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH
CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool
More informationHORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT
HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationBRIZA 22 HYBRID HEATING & COOLING
BRIZA 22 HYBRID HEATING & COOLING Built-in Ceiling: BABC/BT BABC/FT Built-in Wall: BABW/BT BABW/BF BABW/FT BABW/FF INFO SHEET BRIZA 22 HYBRID, COMPACT FANCOIL With EC Greentech EBM-PAPST technology Europe
More informationMHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3
MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model
More informationPCXDMT1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A
PCXDMT1601 VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ Heat Pump 50/60 Hz R-10A Airport Lobby Hospital Factory Shopping Mall Sports Hall Showroom Warehouse
More informationSentinel D-Box Single Fan
Sentinel D-Box Single Fan Duct size to 5mm Performance - Airflow.1 to 1.6m 3 /s Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Aluzinc contstruction suitable for
More informationAir-Cooled Liquid Chiller with integrated hydraulic module
Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800
More informationNEW Acoustic In-Line Fans (ACQ)
NEW Acoustic In-Line Fans (ACQ) Acoustically treated housing, Class O rated, sandwich construction selected for maximum noise absorption Motors protected to IP44 Motor insulation Class B Maximum operating
More informationFFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS
FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL COIL UNITS MAGIC AIRE FFW/FSW/FHW/FHW SERIES COILS ARE ETLC LISTED IN ACCORDANCE WITH UL 995 AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC
More informationHEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL
UT REC - R HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL 1 CONTENTS GENERAL FEATURES... 3 Scope of the unit... 3 Available configurations... 3 Description of the components...
More informationPA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE
PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on
More information36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH
36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua
More informationTypical Applications. Horizontal Installation
ENGINEERING DATA COILS COIL UNITS CB19 AND CBH19 SERIES UP-FLOW, DOWN-FLOW AND HORIZONTAL COIL UNITS *12,600 to 65,500 Btuh (3.7 to 19.2 kw) Cooling Capacity 11,500 to 60,000 Btuh (3.4 to 17.6 kw) Heat
More information24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)
24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua
More informationMODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING
MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without
More informationSubmittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]
BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing
More informationSARAVEL MINI AIR-HANDLING UNIT
CAT-MAHU-2003(1) SARAVEL MINI AIR-HANDLING UNIT 800 TO 5500 CFM ( 1400 TO 9300 m³/hr ) 1 TABLE OF CONTENTS Introduction... 3 Specifications 4 Examples.... 5 Coil Circuiting & Physical Data..... 7 Rating
More informationELITE SERIES R-410A Ready - Multi-Position
PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER
More informationBVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS
BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS MAGIC AIRE BVX SERIES FAN COILS ARE ETLC LISTED IN ACCORDANCE WITH UL 1995 AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPANY,
More informationRAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL
RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAVS RARM RARS RAVE RAVM RAVL RARP RISER www.superiorrex.com RAV Series: VERTICAL HI-RISE CONCEALED SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Model
More informationClimas y Proyectos Leyco, S.A. de C.V.
GENERAL DESCRIPTION : FURNISH AND INSTALL MULTI COMPONENT ROOF MOUNTED LEYCO, MODEL CAH CUSTOM AIR HANDLER MADE SELF-CONTAINED, WEATHER RESISTANT, AIR HANDLING UNITS PER MODEL NUMBER, AND PERFORMANCE DATA
More informationROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING
ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without
More informationPCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A
PCXAU161 VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ Heat Pump 5/6 Hz R-1A An industry first, the VRV air handling unit has been designed and engineered
More informationFan coil units MAJOR 2 CV/CH
CH 41 D CV 1 D MAJOR 2: Design and performance HEE impeller for increased performance Motor optional MAJOR 2 is a non-independant chilled and/or hot water supplied air conditioning Comfort unit for the
More informationSLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw
Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features
More informationMODULAR AIR HANDLING UNITS GAH SERIES
MODULAR AIR HANDLING UNITS GAH SERIES 15 Models with Air Flows from 2,250 Cu.m/hr upto 77,800 Cu.m/hr Suitable for both Standard and District Cooling Applications GAH-TC-10-13 CONTENTS Design 2 Various
More informationELTAFANTECH Air Handling Unit 700 up to 42,000 CFM
an ELTA GROUP company ELTAFANTECH 700 up to 42,000 CFM INNOVATIVE Design & Performance INTRODUCTION There are 24 standard sizes of optimally engineered s to handle air volumes from 700 CFM to 42,000CFM.
More informationDual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN
Dual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN > > Used for small to medium Freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment
More informationPA55 10 SEER FEATURES 2 THRU 5 TON SINGLE PACKAGE AIR CONDITIONER
PACKAGE AIR CONDITIONER PA55 10 SEER C 2 THRU 5 TON SINGLE PACKAGE AIR CONDITIONER FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester
More informationFS Fan-Coil Units Hi-Rise, Vertical
FS Fan-Coil Units Hi-Rise, Vertical FSC Concealed Dimensional Data 4-PIPE 2-PIPE TOP VIEWS Page Trims Short (5/8") Here! SIDE VIEW FRONT VIEW Dimensions Unit Size A B Single/Double Supply C D E 03 & 04
More informationSECTION AIR TERMINAL UNITS
SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,
More informationFAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES
FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing
More informationSPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11
AIR HANDLING UNIT (DOUBLE SKIN) MODEL: DS-CW/DX-AHU-H (Chilled Water or Direct Expansion) CAPACITY: 3.3 to 125 Nominal Tons 39,000 to 1,500,000 BtuH 11.4 to 439.5 KW 1,300 to 50,000 CFM Benefits Horizontal
More informationFeatures: Available in horizontal and vertical units
Features: Available in horizontal and vertical units Ideal for Shopping Malls, Retail Outlets and Office Receptions Can be supplied in a large range of colours and finishes Numerous mounting bracket arrangements
More information