1 technical data RQ-B7 Pair/Twin/Triple/Double Twin Application air conditioning systems Split Sky Air
2 Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin Europe N.V. participates in the Eurovent Certification Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP) and Fan Coil Units (FC); the certified data of certified models are listed in the Eurovent Directory. Specifications are subject to change without prior notice. Zandvoordestraat 300 B Ostend Belgium EEDE05-1/3 05/2005 Prepared in Belgium by Goekint Graphics
3 TABLE OF CONTENTS RQ-B7 1 Features Specifications Technical Specifications Electrical Specifications Electrical data Safety device settings Options Capacity tables Combination table Cooling capacity tables Cooling capacity tables simultaneous operation Heating capacity tables Heating capacity tables simultaneous operation Dimensional drawing & centre of gravity Dimensional drawing Centre of gravity Piping diagram Wiring diagram Wiring diagram External connection diagram Sound data Sound pressure spectrum Sound power spectrum Operation range Split Sky Air Outdoor Units 1
4 t i l t Outdoor Units R-410A RQ-B7 o a o 07 d 1B 4- puq - RO S1 Features 1 Outdoor units for pair, twin, triple, double twin application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall. Outdoor units are fitted with a scroll compressor, renowned for low noise and high energy efficiency. The piping connections can be accessed from underneath, front, side or rear. The sevice valves are hidden inside the casing. A special acryl precoated fin for anti-corrosion treatment on the heat exchanger ensures greater resistance against severe weather conditions 2 Split Sky Air Outdoor Units
5 2 Specifications 2-1 TECHNICAL SPECIFICATIONS RQB7V3B RQB7W1B RQB7V3B RQB7W1B RQ125B7W1B Casing Colour Daikin White Material Painted galvanized steel plate Dimensions Packing Height mm Width mm Depth mm Unit Height mm Width mm Depth mm Weight Machine Weight kg Gross Weight kg Heat Exchanger Dimensions Length mm Nr of Rows Fin Pitch mm Nr of Passes Face Area m Nr of Stages Tube type Hi-XSS cooling tube Fin Type Non-symmetric waffle louvre Treatment Anti-corrosion treatment (PE) Fan Type Direct Drive Propeller Discharge direction Horizontal Quantity Air Flow Rate Cooling m 3 /min (nominal) Heating m 3 /min Motor Quantity Model P47L11S Position Lower Motor Speed (nominal Steps at 230V) Fan Motor Output W Drive direct drive Position Upper Motor Speed (nominal Steps 3 at 230V) Fan Motor Output W 65 Drive direct drive Compressor Quantity Motor Model JT90G-V1N JT90G-YE JT125G-V1N JT125G-YE JT160G-YE Type Hermetically sealed scroll compressor Motor Output W Starting Method Direct Crankcase W Heater Operation Range Cooling Min CDB Max CDB Heating Min CWB Max CWB Sound Level (nominal) Cooling Sound Power Sound Pressure dba dba Refrigerant Type R-410A Charge kg Control Expansion valve (electronic type) Nr of Circuits Split Sky Air Outdoor Units 3
6 2 2-1 TECHNICAL SPECIFICATIONS RQB7V3B RQB7W1B RQB7V3B RQB7W1B RQ125B7W1B Refrigerant Oil Type Daphne FVC68D Charged Volume l Piping Liquid (OD) Quantity connections Type Flare connection Diameter (OD) mm Gas Quantity Type Flare connection Diameter (OD) mm Drain Quantity Type Hole Diameter mm (OD) Piping Length Minimum m Maximum m Equivalent m Chargeless m Installation height difference Maximum m Max. internunit level difference m Heat Insulation Both liquid and gas pipes Defrost Method Reversed cycle Defrost Control Sensor for outdoor heat exchanger temperature Capacity Control Method None Safety Devices Reverse phase protector PC board fuse Overcurrent relay (compressor) Low pressure switch High pressure switch Fan motor thermal protector Standard Item Declaration of conformity Accessories Quantity Item Installation manual Quantity Split Sky Air Outdoor Units
7 2 Specifications 2-2 ELECTRICAL SPECIFICATIONS RQB7V3B RQB7W1B RQB7V3B RQB7W1B RQ125B7W1B Power Supply Name V3 W1 V3 W1 W1 Phase 1 3N 1 3N 3N Frequency Hz Voltage V Current Recomended fuses A Voltage range Minimum V Maximum V Wiring connections Power Supply Intake For Power Supply Quantity Remark 3 wires (earth wire included) 5 wires (earth wire included) 3 wires (earth wire included) 5 wires (earth wire included) 5 wires (earth wire included) For connection Quantity with indoor Remark 4 wires (earth wire included) Outdoor unit only 2 1 Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound level drawings of this chapter. 2 The sound power level is an absolute value indicating the power which a sound source generates. 3 Sound values are measured in a semi-anechoic room. 4 Heating capacity is only applicable for combination with heat pump outdoor unit. 5 In case of drain piping for outdoor unit, drain piping kit (option) is needed. 6 Nominal cooling capacities are based on : indoor temperature : 27 CDB, 19 CWB, outdoor temperature : 35 CDB, equivalent refrigerant piping : 7.5m, level difference : 0m. 7 Nominal heating capacities are based on : indoor temperature : 20 CDB, outdoor temperature : 7 CDB, 6 CWB, equivalent refrigerant piping : 7.5m, level difference : 0m. Split Sky Air Outdoor Units 5
8 2 2 Specifications 2-3 Electrical data Electrical data Unit combination Power supply Comp. OFM IFM Indoor unit Outdoor unit Hz-volts Voltage range MCA TOCA MFA MSC RLA kw FLA kw FLA FCQ RQB7V3B FUQ RQB7V3B Max. 50Hz-2 FHQ RQB7V3B V Min. 50Hz-207V FAQ RQB7V3B FBQ RQB7V3B FCQ RQB7W1B / FUQ RQB7W1B / Max. 50Hz-440/253V FHQ RQB7W1B / Min. 50Hz-0/207V FAQ RQB7W1B / FBQ RQB7W1B / SYMBOLS MCA : Min. Circuit Amps TOCA : Total Over Current Amps MFA : Max. Fuse Amps (See note 7) LRA : Locked Rotor Amps RLA : Rated Load Amps OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps kw : Fan Motor Rated Output 1 RLA is based on the following conditions: Indoor temperature 27 CDB/19.5 CWB Outdoor temperature 35 CDB 2 TOCA means the total value of each OC set 3 Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits 4 Maximum allowable voltage unbalance between phases is 2% 5 MCA/MFA MCA = 1.25 x RLA + all FLA MFA 2.25 x RLA + all FLA (next lower standard fuse rating min 16A) 6 Select wire size based on the larger value of MCA or TOCA 7 Instead of fuse, use circuit breaker 8 For more details concerning conditional connections, see select Daikin Documentation and select conditional connection, the requested product type and English from the drop down lists, click the search button. Finally, click on the document title of your choice. 3TW A 6 Split Sky Air Outdoor Units
9 2 Specifications 2-3 Electrical data Electrical data 2 Unit combination Power supply Comp. OFM IFM Indoor unit Outdoor unit Hz-volts Voltage range MCA TOCA MFA MSC RLA kw FLA kw FLA FCQ RQB7V3B FUQ RQB7V3B Max. 50Hz-2 FHQ RQB7V3B V Min. 50Hz-207V FAQ RQB7V3B FBQ RQB7V3B FCQ RQB7W1B / FUQ RQB7W1B / Max. 50Hz-440/253V FHQ RQB7W1B / Min. 50Hz-0/207V FAQ RQB7W1B / FBQ RQB7W1B / SYMBOLS MCA : Min. Circuit Amps TOCA : Total Over Current Amps MFA : Max. Fuse Amps (See note 7) LRA : Locked Rotor Amps RLA : Rated Load Amps OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps kw : Fan Motor Rated Output 1 RLA is based on the following conditions: Indoor temperature 27 CDB/19.5 CWB Outdoor temperature 35 CDB 2 TOCA means the total value of each OC set 3 Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits 4 Maximum allowable voltage unbalance between phases is 2% 5 MCA/MFA MCA = 1.25 x RLA + all FLA MFA 2.25 x RLA + all FLA (next lower standard fuse rating min 16A) 6 Select wire size based on the larger value of MCA or TOCA 7 Instead of fuse, use circuit breaker 8 For more details concerning conditional connections, see select Daikin Documentation and select conditional connection, the requested product type and English from the drop down lists, click the search button. Finally, click on the document title of your choice. 3TW B Split Sky Air Outdoor Units 7
10 2 2 Specifications 2-3 Electrical data Electrical data Unit combination Power supply Comp. OFM IFM Indoor unit Outdoor unit Hz-volts Voltage range MCA TOCA MFA MSC RLA kw FLA kw FLA FCQ125 RQ125B7W1B / FUQ125 RQ125B7W1B / FHQ125 RQ125B7W1B /230 Max. 50Hz-440/253V Min. 50Hz-0/207V FBQ125 RQ125B7W1B / FDQ125 RQ125B7W1B / SYMBOLS MCA : Min. Circuit Amps TOCA : Total Over Current Amps MFA : Max. Fuse Amps (See note 7) LRA : Locked Rotor Amps RLA : Rated Load Amps OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps kw : Fan Motor Rated Output 1 RLA is based on the following conditions: Indoor temperature 27 CDB/19.5 CWB Outdoor temperature 35 CDB 2 TOCA means the total value of each OC set 3 Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits 4 Maximum allowable voltage unbalance between phases is 2% 5 MCA/MFA MCA = 1.25 x RLA + all FLA MFA 2.25 x RLA + all FLA (next lower standard fuse rating min 16A) 6 Select wire size based on the larger value of MCA or TOCA 7 Instead of fuse, use circuit breaker 8 For more details concerning conditional connections, see select Daikin Documentation and select conditional connection, the requested product type and English from the drop down lists, click the search button. Finally, click on the document title of your choice. 3TW269-9B 8 Split Sky Air Outdoor Units
11 2 Specifications 2-4 Safety device settings R(Q)(R)-125B7 2 Safety device Model Fan motor thermal protector HPS LPS Max discharge temperature Overcurrent relay RQB7V3B RQB7V3B RRB7V3B RRB7V3B RQB7W1B RQB7W1B RQ125B7W1B RRB7W1B RRB7W1B RR125B7W1B Off 135 ± 5 C On 95 ± 15 C Off / Mpa On / Mpa Off / Mpa On / Mpa By thermistor and software control By overcurrent sensor and software control 4TW B Split Sky Air Outdoor Units 9
12 3 Options 3 Available option for RQ-125B7(V3,W1)B and RR-125B7(V3,W1)B Central drain plug Refrigerant branch piping Name of option Kit name RQB7 RQB7 RQ125B7 RRB7 RRB7 RR125B7 KKPJ5F180 Twin KHRQ22M20TA7 Triple - KHRQ127H7 - KHRQ127H7 3TW Split Sky Air Outdoor Units
13 4 Capacity tables 4-1 Combination table Possible combinations and standard capacity for twin and triple operation 4 Possible indoor combination Outdoor models Twin Simultaneous operation Triple OUT OUT IN IN IN IN IN RQB7V3/W1 RRB7V3/W (KHRQ22M20TA7) RQB7V3/W1 RRB7V3/W (KHRQ22M20TA7) (KHRQ22M20TA7) 35- (KHRQ22M20TA7) (KHRQ127H7) RQ125B7W1 RR125B7W (KHRQ22M20TA7) 50- (KHRQ22M20TA7) (KHRQ127H7) 1 Possible indoor types: FCQ 35- FFQ FUQ FHQ 35- FAQ FBQ 35-2 Individual indoor capacities are not given because the combinations are for simultaneous operation (= indoor units installed in same room). 3 When different indoor models are used in combination, designate the remote controller that is equipped with the most functions as the main unit. 4 Between brackets are the required Refnet kits mentioned, that are necessary to install the combination. 5 For unit specification of the outdoor units and the indoor units refer to the unit sepcifications mentioned for pair systems. 6 Nominal cooling capacities are based on the following conditions: indoor air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB. Nominal heating capacities are based on the following conditions: indoor air temperature: 20 CDB, outdoor temperature 7 CDB, 6 CWB. 3TW Split Sky Air Outdoor Units 11
14 4 4 Capacity tables 4-2 Cooling capacity tables FBQ-125B7V3B + RQ-B7V3B / RQ-125B7W1B Cooling capacity table Outdoor Indoor Outdoor temp. ( CDB) EWB EDB ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 3TW A SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) DB*: Dry bulb temp. ( CDB) TC: Total cooling/heating capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC and SHC are shown by kw V3: 230 V [50 Hz] W1: 400 V [50 Hz] 1. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb SHC* = 0.29 x 60 x AFR (m 3 /min.) x (1 BF) x (DB* EDB)/860 Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length : 7.5 m Level difference : 0 m 6. Air flow rate and BF are tabulated below. Model 125 FBQ AFR 19 BF 0.11 AFR 27 BF 0.2 AFR 35 BF Add the following corrections to power input of each model. Model Supply FBQ V W1 0 V W W Split Sky Air Outdoor Units
15 4 Capacity tables 4-2 Cooling capacity tables FCQ-125B7V3B + RQ-B7V3B / RQ-B7W1B Cooling capacity 4 Outdoor 125 EWB ( C) Indoor EDB ( C) Outdoor temperature ( CDB) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI SYMBOLS AFR: Air flow rate [m3/min.] BF: Bypass factor EWB: Entering wet bulb temp. [ CWB] EDB: Entering dry bulb temp. [ CDB] DB*: Dry bulb temp. [ CDB] TC: Total capacity cooling [kw] SHC: Sensible heat capacity [kw] PI: Power input (Comp. + indoor + outdoor fan motor) [kw] CAUTION TC and SHC are given in kw. V1/V3: 230V [50 Hz] W1: 400V [50Hz] 1 Ratings shown are net capacities. Influence on fan motor heat is included. 2 shows nominal capacities. 3 SHC is based on each EWB and EDB. SHC* = SHC correction for other dry bulb. = 0.29 x 60 x AFR [m3/min.] x (1-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC = SHC. 4 Direct interpolation is permissable. Do not extrapolate. 5 Capacities are based on the folowing conditions. Corresponding refrigerant piping length: 7.5m Level difference: 0m 6 Air flow rate and BF are tabulated below. Model FCQ AFR 18 BF 0.1 AFR 28 BF 0.16 AFR BF Add the following corrections to power input of each model. Model FCQ V W1 0 V W W1 0 3TW Split Sky Air Outdoor Units 13
16 4 4 Capacity tables 4-2 Cooling capacity tables FHQ-125BUV1B + RQ-B7V3B / RQ-125B7W1B Cooling capacity Outdoor 125 EWB ( C) Indoor EDB ( C) Outdoor temperature ( CDB) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI SYMBOLS AFR: Air flow rate [m3/min.] BF: Bypass factor EWB: Entering wet bulb temp. [ CWB] EDB: Entering dry bulb temp. [ CDB] DB*: Dry bulb temp. [ CDB] TC: Total capacity cooling [kw] SHC: Sensible heat capacity [kw] PI: Power input (Comp. + indoor + outdoor fan motor) [kw] CAUTION TC and SHC are given in kw. V1/V3: 230V [50 Hz] W1: 400V [50Hz] 1 Ratings shown are net capacities. Influence on fan motor heat is included. 2 shows nominal capacities. 3 SHC is based on each EWB and EDB. SHC* = SHC correction for other dry bulb. = 0.29 x 60 x AFR [m3/min.] x (1-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC = SHC. 4 Direct interpolation is permissable. Do not extrapolate. 5 Capacities are based on the folowing conditions. Corresponding refrigerant piping length: 7.5m Level difference: 0m 6 Air flow rate and BF are tabulated below. Model FHQ AFR 18 BF 0.1 AFR 24 BF 0.14 AFR BF Add the following corrections to power input of each model. Model FHQ V W1 0 V W W1 0 3TW Split Sky Air Outdoor Units
17 4 Capacity tables 4-2 Cooling capacity tables FUQ-125BUV1B + RQ-B7V3B / RQ-125B7W1B 4 Cooling capacity table Outdoor Indoor Outdoor temp. ( CDB) EWB EDB ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 3TW A SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) DB*: Dry bulb temp. ( CDB) TC: Total cooling/heating capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC and SHC are shown by kw V1/V3: 230 V [50 Hz] W1: 400 V [50 Hz] 1. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb SHC* = 0.29 x 60 x AFR (m 3 /min.) x (1 BF) x (DB* EDB)/860 Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length : 7.5 m Level difference : 0 m 6. Air flow rate and BF are tabulated below. Model 125 FUQ AFR 19 BF 0.07 AFR 29 BF 0.07 AFR 45 BF Add the following corrections to power input of each model. Model Supply FUQ V W1 0 V W W1 0 Split Sky Air Outdoor Units 15
18 4 Capacity tables Cooling capacity tables FAQ-BUV1B + RQ-B7V3B / RQ-B7W1B Cooling capacity Outdoor EWB ( C) Indoor EDB ( C) Outdoor temperature ( CDB) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI SYMBOLS FR: Air flow rate [m3/min.] BF: Bypass factor EWB: Entering wet bulb temp. [ CWB] EDB: Entering dry bulb temp. [ CDB] DB*: Dry bulb temp. [ CDB] TC: Total capacity cooling [kw] SHC: Sensible heat capacity [kw] PI: Power input (Comp. + indoor + outdoor fan motor) [kw] CAUTION TC and SHC are given in kw. V1/V3: 230V [50 Hz] W1: 400V [50Hz] 1 Ratings shown are net capacities. Influence on fan motor heat is included. 2 shows nominal capacities. 3 SHC is based on each EWB and EDB. SHC* = SHC correction for other dry bulb. = 0.29 x 60 x AFR [m3/min.] x (1-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC = SHC. 4 Direct interpolation is permissable. Do not extrapolate. 5 Capacities are based on the folowing conditions. Corresponding refrigerant piping length: 7.5m Level difference: 0m 6 Air flow rate and BF are tabulated below. Model FAQ AFR 19 BF 0.08 AFR 23 BF Add the following corrections to power input of each model. Model FAQ V W1 0 V W1 0 3TW Split Sky Air Outdoor Units
19 4 Capacity tables 4-2 Cooling capacity tables FDQ125B7V3B + RQ125B7W1B Cooling capacity 4 Outdoor 125 EWB ( C) Indoor EDB ( C) Outdoor temperature ( CDB) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI SYMBOLS AFR: Air flow rate [m3/min.] BF: Bypass factor EWB: Entering wet bulb temp. [ CWB] EDB: Entering dry bulb temp. [ CDB] DB*: Dry bulb temp. [ CDB] TC: Total capacity cooling [kw] SHC: Sensible heat capacity [kw] PI: Power input (Comp. + indoor + outdoor fan motor) [kw] CAUTION TC and SHC are given in kw. V1/V3: 230V [50 Hz] W1: 400V [50Hz] 1 Ratings shown are net capacities. Influence on fan motor heat is included. 2 shows nominal capacities. 3 SHC is based on each EWB and EDB. SHC* = SHC correction for other dry bulb. = 0.29 x 60 x AFR [m3/min.] x (1-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC = SHC. 4 Direct interpolation is permissable. Do not extrapolate. 5 Capacities are based on the folowing conditions. Corresponding refrigerant piping length: 7.5m Level difference: 0m 6 Air flow rate and BF are tabulated below. Model FDQ AFR BF TW Split Sky Air Outdoor Units 17
20 4 Capacity tables Cooling capacity tables simultaneous operation Simultaneous operation RQ--125B7 and RR--125B7 Cooling capacity Outdoor 125 EWB ( C) Indoor RQ RR Outdoor temperature ( CDB) Outdoor temperature ( CDB) EDB ( C) TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI SYMBOLS EWB: Entering wet bulb temp. [ CWB] EDB: Entering dry bulb temp. [ CDB] TC: Total capacity heating [kw] PI o: Power input of outdoor unit [kw] PI corr1: Correction factor for PI depending on voltage of outdoor [kw] PI corr2: Correction factor for PI depending used indoor units [kw] PI: Total power input [kw] PI = PI o + PI corr1 + PI corr2 e.g. RQB7V3B + FBQB7V3B + FHQ35BUV1B PI = = 4.2 kw 1 Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2 shows nominal capacities. 3 Capacities are based on the folowing conditions. Corresponding refrigerant piping length: 7.5m Level difference: 0m 4 Direct interpolation is permissable. Do not extrapolate. 5 Add the following correction to the power input for the different outdoor units (PI corr1). Outdoor model Power supply V3 W1 RQ RQ RR RR Add the following correction to the power input for each connected indoor unit (PI corr2). Indoor Indoor types model FBQ FHQ FFQ FCQ FAQ FUQ The total capacity does not change with differrent combination of indoor units. 3TW Split Sky Air Outdoor Units
21 4 Capacity tables 4-4 Heating capacity tables FBQ-B7V3B + RQ-B7V3B / RQ-B7W1B Heating capacity 4 Outdoor 125 Indoor Outdoor temperature ( CDB) EDB ( C) TC PI TC PI TC PI TC PI TC PI TC PI SYMBOLS FR: Air flow rate [m3/min.] BF: Bypass factor EWB: Entering wet bulb temp. [ CWB] EDB: Entering dry bulb temp. [ CDB] DB*: Dry bulb temp. [ CDB] TC: Total capacity cooling [kw] SHC: Sensible heat capacity [kw] PI: Power input (Comp. + indoor + outdoor fan motor) [kw] CAUTION TC and SHC are given in kw. V1/V3: 230V [50 Hz] W1: 400V [50Hz] 1 Ratings shown are net capacities. Influence on fan motor heat is included. 2 shows nominal capacities. 3 SHC is based on each EWB and EDB. SHC* = SHC correction for other dry bulb. = 0.29 x 60 x AFR [m3/min.] x (1-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC = SHC. 4 Direct interpolation is permissable. Do not extrapolate. 5 Capacities are based on the folowing conditions. Outdoor iar: 85%RH. However, the condition on nominal capacity is 7 CDB/6 CWB. Corresponding refrigerant piping length: 7.5m Level difference: 0m 6 Air flow rate and BF are tabulated below. Model FBQ AFR 19 BF 0.11 AFR 23 BF 0.2 AFR BF Add the following corrections to power input of each model. Model FBQ V3 0 W1 0 V W W1 0 3TW Split Sky Air Outdoor Units 19
22 4 Capacity tables Heating capacity tables FCQ-125B7V3B + RQ-B7V3B / RQ-125B7W1B Heating capacity Outdoor 125 Indoor Outdoor temperature ( CDB) EDB ( C) TC PI TC PI TC PI TC PI TC PI TC PI SYMBOLS FR: Air flow rate [m3/min.] BF: Bypass factor EWB: Entering wet bulb temp. [ CWB] EDB: Entering dry bulb temp. [ CDB] DB*: Dry bulb temp. [ CDB] TC: Total capacity cooling [kw] SHC: Sensible heat capacity [kw] PI: Power input (Comp. + indoor + outdoor fan motor) [kw] CAUTION TC and SHC are given in kw. V1/V3: 230V [50 Hz] W1: 400V [50Hz] 1 Ratings shown are net capacities. Influence on fan motor heat is included. 2 shows nominal capacities. 3 SHC is based on each EWB and EDB. SHC* = SHC correction for other dry bulb. = 0.29 x 60 x AFR [m3/min.] x (1-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC = SHC. 4 Direct interpolation is permissable. Do not extrapolate. 5 Capacities are based on the folowing conditions. Outdoor air: 85%RH. However, the condition on nominal capacity is 7 CDB/6 CWB. Corresponding refrigerant piping length: 7.5m Level difference: 0m 6 Air flow rate and BF are tabulated below. Model FCQ AFR 18 BF 0.1 AFR 28 BF 0.16 AFR BF Add the following corrections to power input of each model. Model FCQ V W1 0 V W W1 0 3TW Split Sky Air Outdoor Units
23 4 Capacity tables 4-4 Heating capacity tables FHQ-125BUV1B + RQ-B7V3B / RQ-125B7W1B Heating capacity 4 Outdoor 125 Indoor Outdoor temperature ( CDB) EDB ( C) TC PI TC PI TC PI TC PI TC PI TC PI SYMBOLS FR: Air flow rate [m3/min.] BF: Bypass factor EWB: Entering wet bulb temp. [ CWB] EDB: Entering dry bulb temp. [ CDB] DB*: Dry bulb temp. [ CDB] TC: Total capacity cooling [kw] SHC: Sensible heat capacity [kw] PI: Power input (Comp. + indoor + outdoor fan motor) [kw] CAUTION TC and SHC are given in kw. V1/V3: 230V [50 Hz] W1: 400V [50Hz] 1 Ratings shown are net capacities. Influence on fan motor heat is included. 2 shows nominal capacities. 3 SHC is based on each EWB and EDB. SHC* = SHC correction for other dry bulb. = 0.29 x 60 x AFR [m3/min.] x (1-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC = SHC. 4 Direct interpolation is permissable. Do not extrapolate. 5 Capacities are based on the folowing conditions. Outdoor iar: 85%RH. However, the condition on nominal capacity is 7 CDB/6 CWB. Corresponding refrigerant piping length: 7.5m Level difference: 0m 6 Air flow rate and BF are tabulated below. Model FHQ AFR 17 BF 0.1 AFR 24 BF 0.14 AFR BF Add the following corrections to power input of each model. Model FHQ V W1 0 V W W1 0 3TW Split Sky Air Outdoor Units 21
24 4 Capacity tables Heating capacity tables FUQ-125BUV1B + RQ-B7V3B / RQ-125B7W1B Heating capacity Outdoor 125 Indoor Outdoor temperature ( CDB) EDB ( C) TC PI TC PI TC PI TC PI TC PI TC PI SYMBOLS FR: Air flow rate [m3/min.] BF: Bypass factor EWB: Entering wet bulb temp. [ CWB] EDB: Entering dry bulb temp. [ CDB] DB*: Dry bulb temp. [ CDB] TC: Total capacity cooling [kw] SHC: Sensible heat capacity [kw] PI: Power input (Comp. + indoor + outdoor fan motor) [kw] CAUTION TC and SHC are given in kw. V1/V3: 230V [50 Hz] W1: 400V [50Hz] 1 Ratings shown are net capacities. Influence on fan motor heat is included. 2 shows nominal capacities. 3 SHC is based on each EWB and EDB. SHC* = SHC correction for other dry bulb. = 0.29 x 60 x AFR [m3/min.] x (1-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC = SHC. 4 Direct interpolation is permissable. Do not extrapolate. 5 Capacities are based on the folowing conditions. Outdoor iar: 85%RH. However, the condition on nominal capacity is 7 CDB/6 CWB. Corresponding refrigerant piping length: 7.5m Level difference: 0m 6 Air flow rate and BF are tabulated below. Model FUQ AFR 19 BF 0.07 AFR 29 BF 0.07 AFR BF Add the following corrections to power input of each model. Model FUQ V W1 0 V W W1 0 3TW Split Sky Air Outdoor Units
25 4 Capacity tables 4-4 Heating capacity tables FAQ-BUV1B + RQ-B7V3B / RQ-B7W1B 4 Heating capacity table Outdoor Indoor outdoor temperature ( CWB) EDB ( C) TC PI TC PI TC PI TC PI TC PI TC PI 3TW A SYMBOLS AFR: Air flow rate (m 3 /min) EDB: Entering dry bulb temp. ( CDB) WB: Wet bulb temperature ( CWB) TC: Total cooling/heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC is shown by kw V1/V3: 230 V [50 Hz] W1: 400 V [50 Hz] 1. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. Capacities are based on following conditions: * outdoor air : 85 % RH. however, the condition on nominal capacity is 7 CDB/6 CWB * Corresponding refrigerant piping length : 7.5 m Level difference : 0 m 4. Direct interpolation is permissible. Do not extrapolate. 5. Air flow rate and BF are tabulated below. Model FAQ AFR 19 BF 0.08 AFR 23 BF Add the following corrections to power input of each model. Model Supply FAQ V W1 0 V W1 0 Split Sky Air Outdoor Units 23
26 4 Capacity tables Heating capacity tables FDQ125B7V3B + RQ125B7W1B Heating capacity Outdoor 125 Indoor Outdoor temperature ( CDB) EDB ( C) TC PI TC PI TC PI TC PI TC PI TC PI SYMBOLS FR: Air flow rate [m3/min.] BF: Bypass factor EWB: Entering wet bulb temp. [ CWB] EDB: Entering dry bulb temp. [ CDB] DB*: Dry bulb temp. [ CDB] TC: Total capacity cooling [kw] SHC: Sensible heat capacity [kw] PI: Power input (Comp. + indoor + outdoor fan motor) [kw] CAUTION TC and SHC are given in kw. V1/V3: 230V [50 Hz] W1: 400V [50Hz] 1 Ratings shown are net capacities. Influence on fan motor heat is included. 2 shows nominal capacities. 3 SHC is based on each EWB and EDB. SHC* = SHC correction for other dry bulb. = 0.29 x 60 x AFR [m3/min.] x (1-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC = SHC. 4 Direct interpolation is permissable. Do not extrapolate. 5 Capacities are based on the folowing conditions. Outdoor air: 85%RH. However, the condition on nominal capacity is 7 CDB/6 CWB. Corresponding refrigerant piping length: 7.5m Level difference: 0m 6 Air flow rate and BF are tabulated below. Model FDQ AFR BF TW Split Sky Air Outdoor Units
27 4 Capacity tables 4-5 Heating capacity tables simultaneous operation Simultaneous operation RQ--125B7 Heating capacity 4 Outdoor 125 Indoor Outdoor temperature ( CWB) EDB ( C) TC PI TC PI TC PI TC PI TC PI TC PI SYMBOLS EWB: Entering wet bulb temp. [ CWB] EDB: Entering dry bulb temp. [ CDB] TC: Total capacity heating [kw] PI o: Power input of outdoor unit [kw] PI corr1: Correction factor for PI depending on voltage of outdoor [kw] PI corr2: Correction factor for PI depending used indoor units [kw] PI: Total power input [kw] PI = PI o + PI corr1 + PI corr2 e.g. RQB7V3B + FBQB7V3B + FHQ35BUV1B PI = = 4.46 kw 1 Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2 shows nominal capacities. 3 Capacities are based on the folowing conditions. Corresponding refrigerant piping length: 7.5m Level difference: 0m Outdoor air: 85% RH However, when outdoor air temperature is 7 CDB, wet bulb temperature is 6 CWB. 4 Direct interpolation is permissable. Do not extrapolate. 5 Add the following correction to the power input for the different outdoor units (PI corr1). Outdoor model Power supply V3 W1 RQ RQ Add the following correction to the power input for each connected indoor unit (PI corr2). Indoor Indoor types model FBQ FHQ FFQ FCQ FAQ FUQ The total capacity does not change with differrent combination of indoor units. 3TW Split Sky Air Outdoor Units 25
28 5 Dimensional drawing & centre of gravity Dimensional drawing RQB7 hole for anchor bolt 4-M12 LEGEND 1 Gas pipe connection ø15.9 flare 2 Liquid pipe connection ø9.5 flare 3 Service port (in the unit) 4 Grounding terminal M5 (in switch box) 5 Refrigerant piping intake 6 Power supply wiring intake (knock out hole ø34) 7 Control wiring intake (knock out hole ø27) 8 Drain outlet 3TW RQB7 hole for anchor bolt 4-M12 LEGEND 1 Gas pipe connection ø15.9 flare 2 Liquid pipe connection ø9.5 flare 3 Service port (in the unit) 4 Grounding terminal M5 (in switch box) 5 Refrigerant piping intake 6 Power supply wiring intake (knock out hole ø34) 7 Control wiring intake (knock out hole ø27) 8 Drain outlet 3TW Split Sky Air Outdoor Units
29 5 Dimensional drawing & centre of gravity 5-1 Dimensional drawing RQ125B7 5 hole for anchor bolt 4-M12 LEGEND 1 Gas pipe connection ø15.9 flare 2 Liquid pipe connection ø9.5 flare 3 Service port (in the unit) 4 Grounding terminal M5 (in switch box) 5 Refrigerant piping intake 6 Power supply wiring intake (knock out hole ø34) 7 Control wiring intake (knock out hole ø27) 8 Drain outlet 3TW264-1 Split Sky Air Outdoor Units 27
30 5 5 Dimensional drawing & centre of gravity 5-2 Centre of gravity R(Q)(R)B7 3TW B R(Q)(R)B7 3TW B 28 Split Sky Air Outdoor Units
31 5 Dimensional drawing & centre of gravity 5-2 Centre of gravity 5 R(Q)(R)125B7 3TW269-5B Split Sky Air Outdoor Units 29
32 6 Piping diagram 6 RQ-125B7 (pair) Solenoid valve Electronic expansion valve One way valve One way valve Filter Filter Heat exchanger One way valve One way valve Strainer Receiver Service port 5/16 Capillary tube One way valve Indoor unit Heat exchanger 4-way valve Filter Low pressure switch High pressure switch Muffler Field piping ø9,5 C 1220T-0 Service port 5/16 Filter Field piping ø15,9 C 1220T-0 Compressor Outdoor unit Stop valve (with service port - 5/16 flare) NOTE 1 The pipes between the branch and the indoor units should have the same size as the indoor connections. Check valve Flexible connection Flare connection Screw connection Flange connection Pinched pipe Spinned pipe 3TW RQ-125B7 (twin) Solenoid valve Electronic expansion valve Indoor unit Heat exchanger One way valve One way valve Filter Filter Heat exchanger One way valve One way valve Field piping Strainer Receiver Filter Field piping Service port 5/16 Capillary tube One way valve 4-way valve Heat exchanger Indoor unit Filter Low pressure switch High pressure switch Muffler Field piping ø9,5 C 1220T-0 Service port 5/16 Field piping ø15,9 C 1220T-0 Compressor Field piping Outdoor unit Filter Field piping Stop valve (with service port - 5/16 flare) Heating Cooling NOTE 1 The pipes between the branch and the indoor units should have the same size as the indoor connections. Check valve Flexible connection Flare connection Screw connection Flange connection Pinched pipe Spinned pipe 3TW Split Sky Air Outdoor Units
33 6 Piping diagram RQ-125B7 (triple) 6 Heat exchanger Indoor unit Solenoid valve Electronic expansion valve One way valve One way valve Filter Field piping Stop valve (with service port - 5/16 flare) Filter One way valve One way valve Heat exchanger Filter Field piping Heat exchanger Indoor unit Strainer Receiver Service port 5/16 Capillary tube One way valve Field piping ø9,5 C 1220T-0 4-way valve Filter Field piping Field piping Filter Low pressure switch High pressure switch Muffler Field piping ø15,9 C 1220T-0 Heat exchanger Indoor unit Branch pipe (option) Service port 5/16 Compressor Outdoor unit - Filter Field piping Field piping NOTE 1 The pipes between the branch and the indoor units should have the same size as the indoor connections. Check valve Flexible connection Flare connection Screw connection Flange connection Pinched pipe Spinned pipe 3TW Split Sky Air Outdoor Units 31
34 7 7 Wiring diagram 7-1 Wiring diagram RQ-B7V3B Power supply 1~50 Hz 230V indoor - class outdoor Switch box (outdoor) NOTE Position of compressor terminal Wire entrance BLK: black BLU: blue ORG: orange Field wiring Terminal RED: red WHT: white YLW: yellow Live Neutral Connector Protective earth (screw) Terminal 1 Confirm the method of setting the dip switch (DS1) by service manual. When the unit is shipped by factory all switches are set to be off. A1P BS1 C1 C3 DS1 E1HC LEGEND Printed circuit board Push button switch (forced defrost-pump down) Capacitor (M1F) Capacitor (M1C) Dip switch Crankcase heater F1U HAP K1M K1R K2R K3R K4R K5R, K6R, Fuse (T6.3/250V) Light emitting diode (service monitor green) Magnetic contactor (M1C) Magnetic relay (K1M) Magnetic relay (Y2S) Magnetic relay (E1HC) Magnetic relay (Y1S) K7R M1C M1F PC Q1DI Q1M R1T R2T R3T Magnetic relay (M1F) Motor compressor Motor fan Power circuit Earth leakage breaker (30 ma) Thermo switch (M1F) Thermistor (Air) Thermistor (Coil) Thermistor (Discharge RC S1PH S1PL SD T1A TC X1M, X2M Y1E pipe) Signal receiver circuit Pressure switch (high) Pressure switch (low) Safety devices input Current transformer Signal transmission circuit Terminal strip Expansion valve Y1S Y2S CT (electronic) 4-way valve Solenoid valve Current transformer 2TW B RQ-B7W1B Switch box (outdoor) indoor - class outdoor Power supply 3N~50 Hz 400V Short circuit connector Field wiring Terminal BLK: black BLU: blue ORG: orange RED: red WHT: white YLW: yellow Position of compressor terminal Live Neutral Connector Protective earth (screw) Wire entrance Terminal A1P BS1 C1 DS1 E1HC F1U, F2U HAP LEGEND Printed circuit board Push button switch (forced defrost-pump down) Capacitor (M1F) Dip switch Crankcase heater Fuse (T6.3/250V) Light emitting diode (service monitor green) K1M Magnetic contactor (M1C) Q1M K1R Magnetic relay (K1M) Q1RP K2R Magnetic relay (Y2S) R1T K3R Magnetic relay (E1HC) R2T K4R Magnetic relay (Y1S) R3T K5R, K6R, K7R Magnetic relay (M1F) RC M1C Motor compressor S1PH M1F Motor fan S1PL PC Power circuit SD Q1DI Earth leakage breaker (30mA) T1A Thermo switch (M1F) Phase reverse circuit Thermistor (Air) Thermistor (Coil) Thermistor (Discharge pipe) Signal receiver circuit Pressure switch (high) Pressure switch (low) Safety devices input Current transformer TC X1M, X2M Y1E Y1S Y2S CT Signal transmission circuit Terminal strip Expansion valve (electronic) 4-way valve Solenoid valve Current transformer NOTE 1 Confirm the method of setting the dip switch (DS1) by service manual. When the unit is shipped by factory all switches are set to be off. 2TW263-1B 32 Split Sky Air Outdoor Units
35 7 Wiring diagram 7-1 Wiring diagram RQ125B7W1B 7 Switch box (outdoor) indoor 125 class outdoor Power supply 3N~50 Hz 400V Field wiring Terminal BLK: black BLU: blue ORG: orange Live Neutral Connector RED: red WHT: white YLW: yellow Protective earth (screw) Terminal Position of compressor terminal Wire entrance A1P BS1 C1 C2 DS1 E1HC F1U, F2U HAP LEGEND Printed circuit board Push button switch (forced defrost-pump down) Capacitor (M1F) Capacitor (M2F) Dip switch Crankcase heater Fuse (T6.3/250V) Light emitting diode K1M K1R K2R K3R K4R K5R, K6R, K7R K8R, K9R, K10R M1C (service monitor green) Magnetic contactor (M1C) Magnetic relay (K1M) Magnetic relay (Y2S) Magnetic relay (E1HC) Magnetic relay (Y1S) Magnetic relay (M1F) Magnetic relay (M2F) Motor compressor M1F, M2F PC Q1DI Q1M Q2M Q1RP R1T R2T R3T RC Motor fan Power circuit Earth leakage breaker (30 ma) Thermo switch (M1F) Thermo switch (M2F) Phase reverse circuit Thermistor (Air) Thermistor (Coil) Thermistor (Discharge pipe) Signal receiver circuit S1PH S1PL SD T1A TC X1M, X2M Y1E Y1S Y2S CT Pressure switch (high) Pressure switch (low) Safety devices input Current transformer Signal transmission circuit Terminal strip Expansion valve (electronic) 4-way valve Solenoid valve Current transformer NOTE 1 Confirm the method of setting the dip switch (DS1) by service manual. When the unit is shipped by factory all switches are set to be off. 2TW266-1B Split Sky Air Outdoor Units 33
36 7 Wiring diagram External connection diagram R(Q)(R)-125B7 I II III M Pair Twin Triple Master S Slave 1 Earth leak detector 2 Fuse 3 Remote controller 4TW Split Sky Air Outdoor Units
technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air
technical data RYP-L7/B7 Pair Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the
More informationtechnical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air
technical data RXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human
More informationSplit-Sky Air RP-B7 Twin/Triple/Double Twin Application
TECHNICAL DATA Split-Sky Air RP-B7 Twin/Triple/Double Twin Application Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment
More informationtechnical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air
technical data MA-GZ7 Multi Model Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect human health
More informationtechnical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air
technical data RKS-C RKS-B Pair Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help
More information1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units
i r -t i l t - Outdoor Units R-40A RZQ7-40C7VB Features V 7n y CU k 0 S 4 oa o 0 d 7 4Q puz RO S Outdoor units for pair, twin, triple, double twin application The Sky Air Inverter is developed for use
More informationOutdoor Units R-410A ARX-GV1B
Outdoor Units R-40A ARX-GVB t A i n y U k BS r o AV t o0g i d- lt4x pur- SRAO 2 Specifications Outdoor Units R-40A ARX-GVB 2- NOMINAL CAPACITY AND NOMINAL INPUT ARX20GVB ARX25GVB ARX5GVB For combination
More informationtechnical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series
technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series Inverter cooling only / heat pump series RSX(Y)P5,8,10K7W1 RSX(Y)P-K7W1 1 Inverter cooling only / heat pump series 1 1 Specifications
More informationtechnical data air conditioning systems MXS-B Multi Application Split Sky Air
technical data MXS-B Multi Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment
More informationAir Conditioning Technical Data RZQG-L(8)Y1
Air Conditioning Technical Data RZQG-L(8)Y TABLE OF CONTENTS RZQG-L(8)Y Features............................................................. 2 2 Specifications.......................................................
More informationSplit-Sky Air RMX-JZ Super Multi Plus
TECHNICAL DATA Split-Sky Air RMX-JZ Super Multi Plus Split Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential
More informationSplit-Sky Air FDYP-B7 Concealed Ceiling Unit
TECHNICAL DATA Split-Sky Air FDYP-B7 Concealed Ceiling Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationAir Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB
Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................
More informationAir Conditioning. Technical Data EEDEN RXZ-N
Air Conditioning Technical Data EEDEN14-100 RXZ-N TABLE OF CONTENTS RXZ-N 1 Features............................................................. 2 2 Specifications.......................................................
More informationEEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air
EEDEN08-00 technical data FDQ-B8V3B9 air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led
More informationtechnical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air
technical data FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette Multi (950mm Split Heat x 950mm) Pump (edited) air conditioning systems Split Sky Air Outdoor Units R40A MXS-DAVMB_E2VB_E7VB Features V i
More informationtechnical data air conditioning systems Round Flow Cassette FXFQ-P9VEB
technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................
More informationSplit-Sky Air FAYP-B Wall Mounted Unit
TECHNICAL DATA Split-Sky Air FAYP-B Wall Mounted Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential
More informationAir Conditioning. Technical Data EEDEN RXZ-N
Air Conditioning Technical Data EEDEN15-100 RXZ-N Outdoor Unit RXZ-N TABLE OF CONTENTS RXZ-N 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning. Technical Data EEDEN RXJ-L
ir Conditioning Technical Data EEDEN5-0 RXJ-L Outdoor Unit RXJ-L TLE OF CONTENTS RXJ-L Features............................................................. Specifications.......................................................
More informationHeating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps
RZQG71L8Y1B RZQG100L8Y1B RZQG125L8Y1B RZQG140L7Y1B Sound pressure level Heating Nom. dba 50 52 53 53 Cooling Nom. dba 48 50 51 52 Night quiet mode Level 1 dba 43 45 45 45 Standard Accessories Item Tie-wraps
More informationROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh
ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered
More informationAir Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r u n i t E E D E N 2-0 0 RXG-K Outdoor Unit Pair application RXG-K TABLE OF CONTENTS RXG-K Features.............................................................
More informationProduct Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )
13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation
More informationAir Conditioning Technical Data RZQSG-L3/9V1
Air Conditioning Technical Data RZQSG-L/9V1 Outdoor Unit RZQSG-L/9V1 TABLE OF CONTENTS RZQSG-L/9V1 1 Features............................................................. 2 2 Specifications.......................................................
More informationR410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2
R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1
More information1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units
t i t l r - I Features s e Cs m B ne d E Ue V s 7 ya P os e oc Q dvn S nr ox VF C Reduction of power consumption of 20% (compared to FXSQ-M8 series) through use of new DC fan Improved comfort thanks to
More informationtechnical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B
technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems Indoor Units
More informationOperating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16
SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT
More informationWCA4**4. Product Specifications
WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationR4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors
More informationN4A6. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,
More informationAir Conditioners. Technical Data. VRV III heat recovery, with connection to heating only hydrobox REYAQ-P
Air Conditioners Technical Data VRV III heat recovery, with connection to heating only hydrobox E E D E N 1 1-2 0 0 REYAQ-P Air Conditioners Technical Data VRV III heat recovery, with connection to heating
More informationTechnical Service Manual
Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........
More informationR4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,
More information6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH
CAE Product Specifications 6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant REFRIGERATION CIRCUIT Copeland scroll compressors on all models with single refrigeration
More informationFan Coil Units. Technical Data
Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Table of Contents Table of Contents 3 Round Flow Cassette...
More informationCompact Four-way Cassette Type
1. Features... 34 2. Specifications... 35 3. Dimensions... 37 4. Service Spaces... 38 5. Piping Diagrams (EXV beside)... 39 6. Wiring Diagrams... 40 7. Capacity Tables... 41 8. Electrical Characteristics...
More informationTechnical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping
More informationCSA6. Product Specifications. SoftSound SXC 2600
16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models
More informationProduct Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES
FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system
More informationProduct Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES
FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system
More informationtechnical data Systems FXMQ-MVE Conceiled ceiling unit (large)
technical data Systems FXMQ-MVE Conceiled ceiling unit (large) FXMQ-MVE 11 Concealed ceiling unit (large) 11 1 Features...2 2 Specifications Technical specifications...3 Electrical specifications...4 Safety
More informationSplit. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B
Split Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Indoor Unit FTXC-A TABLE OF CONTENTS FTXC-A 1 Features.............................................................
More informationR4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT
EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors
More informationHCH6. Product Specifications
HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationCAC SERIES 12-1/2 Thru 20 Ton
CAC SERIES 12-1/2 Thru 20 Ton SPLIT SYSTEM COMMERCIAL AIR CONDITIONER CONSTRUCTION Triple step pre--painted galvanized steal pre--coated inside and out -- using a polyester top coat, over a urethane primer
More informationTons BTU/h S.E.E.R* E.E.R** HSPF
SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum
More informationProduct Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES
FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system
More informationLow Static Pressure Duct(V shape evaporator)
Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...
More informationProduct Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES
Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air
More informationFFQN-C, FCRN-E, FFRN-C
R410A TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FCQN-E, FFQN-C, FCRN-E, FFRN-C Cooling only & Heatpump [50Hz] DAIKIN_FFRN.indb i 12/27/2012 9:28:06 AM DAIKIN_FFRN.indb ii
More information14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/ Single Phase
COMMERCIAL SOUND REFRIGERANT ENVIRONMENTALLY PAD4 Product Specifications 14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/230 1 60 Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A
More informationN4A4 C. Product Specifications
COASTAL 14 SEER AIR CONDITIONER 14 SEER/11.5 12.5 EER R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter drier
More informationR22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]
R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1
More informationAir Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV
Air Conditioning Technical Data Wall mounted unit EEDEN15-100 FTX-GV TABLE OF CONTENTS FTX-GV 1 Features............................................................. 2 2 Specifications.......................................................
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on
More informationTSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker
HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationCFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)
ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV
More informationPRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump)
PRK 00-04 PREVIEW System OZONE FRIENDLY R-407C Series Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) 3DUW#4 2XWGRRU#8QLWV 111111111111111111111111111111111111111111111111111111111111111111111
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationPHR5. Product Specifications
PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R
More informationProduct Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES
LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air
More informationLow Static Pressure Duct (V shape evaporator)
MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...
More informationtechnical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air
technical data FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help
More informationS6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.
TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,
More informationModel RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2
2-8 GENERAL DATA 2.3. INVERTER SERIES 2.3.1. INVERTER (RAS-25YHA2/35YHA3/50YHA2/60YHA2/70YHA2/80YHA2) Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 Power Supply From Outdoor Unit
More informationAir Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8
Air Conditioners Technical Data Individual branch selector for VRV heat recovery (Individual BS box) EEDEN11-200 BSVQ100-250P8 Air Conditioners Technical Data Individual branch selector for VRV heat recovery
More informationOutdoor Units, 50Hz, R410A
LG AIR CONDITIONERS Outdoor Units, 50Hz, R410A 20 Yoido-dong, Youngdungpo-gu, Yoido P.O.Box 355 Seoul 150-721, Korea Phone: 3777-7969 Fax: 3777-5137/8 http://www.lge.com Approvals: EN ISO 9001 BS EN ISO
More information1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...
MCAC-VTSM-2013-08 1. Features... 264 2. Specifications... 265 3. Dimensions... 268 4. Service Spaces... 272 5. Piping Diagrams... 273 6. Wiring Diagrams... 274 7. Capacity Tables... 276 8. Electrical Characteristics...
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)
FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-
More informationCFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available
More informationTechnical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4
More informationEFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER
ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230
More informationProduct Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES
Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air
More informationNXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER
ENVIRONMENTALLY SOUND REFRIGERANT NXA6 Performance Series Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More informationFan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT
Fan Coil Units Technical Data Conceiled ceiling unit ECDEN10-400 FWB-BT Fan Coil Units Technical Data Conceiled ceiling unit ECDEN10-400 FWB-BT TABLE OF CONTENTS FWB-BT 1 Features.............................................................
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationR2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz
3 PHASE HEAT PUMP COMPONENT 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain proper charge of mineral oil Suction line accumulator
More informationDESCRIPTION FEATURES
SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at
More informationCapacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU
Cooling Capacity: Remark: EWT: Enter Water Temp. ( ); Δt: Temperature Difference ( ) DB: Dry Bulb Temp. ( ); WB: Wet Bulb Temp. ( ); TC: Total Cooling Capacity (kw); SC: Sensible Cooling Capacity (kw);
More informationProduct Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits
More informationPackage Air Conditioners
MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment
More informationAir Conditioners. Technical Data UATYQ-CY1
Air Conditioners Technical Data R o o f t o p s E E D E N 2-2 0 UATYQ-CY Air Conditioners Technical Data R o o f t o p s E E D E N 2-2 0 UATYQ-CY Single Unit Rooftop UATYQ-CY TABLE OF CONTENTS UATYQ-CY
More informationR4H4. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More information38P 60Hz Nominal Cooling Capacity Tons HFC R -410A Refrigerant
38P Condensing Units 60Hz 38P 36K 60K 38P 18K 24K Quality Assurance Certificate Reg. No: 04 100 950420 Product Data Catalog Subject to change without notice Manufacturer s Name: Saudi Airconditioning Manufacturing
More informationProduct Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil
FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil
More informationPH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C
PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationQ6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically
More informationService manual MIV V4+ Indoor units
Service manual MIV V4+ Indoor units Floor Standing MVF22A-VA1 MVF28A-VA1 MVF36A-VA1 MV5A-VA1 MVF56A-VA1 MVF71A-VA1 MVF80A-VA1 MVB22A-VA1 MVB28A-VA1 MVB36A-VA1 MVB45A-VA1 MVB56A-VA1 MVB71A-VA1 MVB80A-VA1
More informationR2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz
R2A3 Product Specifications For Use With R 22 Refrigerant AIR CONDITIONER COMPONENT 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain
More informationProduct Data. Features/Benefits. 50SZ SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons
SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 13 SEER Features/Benefits One-piece
More informationS/T Ratio. Input BTU/h
SOUND REFRIGERANT ENVIRONMENTALLY PGD3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT, 2½ to 5 TONS 3 Phase, 208/230 3 60 and 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant
More informationR2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz
R2A3 Product Specifications For Use With R 22 Refrigerant AIR CONDITIONER COMPONENT 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain
More informationTSA6. Product Specifications. SmartComfort TXC 5600
ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed
More information