technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air
|
|
- Matilda James
- 6 years ago
- Views:
Transcription
1 technical data RKS-C RKS-B Pair Application, Inverter Controlled Unit air conditioning systems Split Sky Air
2 Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO900 standard. ISO900 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. Specifications are subject to change without prior notice. Zandvoordestraat 300 B Ostend Belgium Internet: EEDE04-/2 02/2004 Prepared in Belgium by Goekint Graphics
3 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB TABLE OF CONTENTS RKS-C / RKS-B Features Specifications... 3 Technical specifications Electrical specifications 3 Capacity tables Dimensional drawings Operation range Piping diagrams Wiring diagrams Sound level Sound level data Sound pressure spectrum 9 Accessories Standard accessories Optional accessories 0 Center of gravity Installation Split - Sky Air Outdoor Units
4 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB Features s for pair application + Daikin outdoor units can be mounted easily on a roof or terrace or simply placed against an outside wall. They are fitted with a swing compressor, renowned for its low noise and high energy efficiency. 2 Split - Sky Air Outdoor Units
5 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 2 Specifications TECHNICAL SPECIFICATIONS OUTDOOR UNITS RKS20CVMB RKS25CVMB RKS35B/CVMB DIMENSIONS Unit H mm 550 W mm 765 D mm 285 WEIGHT kg 3 COLOUR Unit Ivory white SOUND LEVEL Sound pressure () (Cooling) high/low db(a) 46/43 46/43 47/44 Sound power (2) (Cooling) high db(a) FAN Air flow rate (Cooling) high/low m 3 /min 36.2/ / /24.9 Speed (Cooling) high rpm low rpm Model Propeller fan Motor output W 3 HEAT EXCHANGER Type WH fin, J7Hi-XA tube Rows x stages x fin pitch mm 2 x 2 x.4 2 x 24 x.4 REFRIGERANT CIRCUIT Refrigerant type R-40A Refrigerant charge kg Maximum allowable distance between indoor m and outdoor Maximum allowable level difference m Refrigerant control Motor operated expansion valve COMPRESSOR Type Hermetically sealed swing type Model YC23NXD#A Motor output 600 Oil type FVC50K Oil charge volume! PIPING CONNECTIONS liquid mm φ6.4 gas mm φ9.5 drain mm φ8.0 INSULATION MATERIAL Heat insulation Both liquid and gas pipes 2 ELECTRICAL SPECIFICATIONS OUTDOOR UNITS RKS20CVMB RKS25CVMB RKS35B/CVMB CURRENT Nominal running current cooling A Max. running current cooling A Please refer to electrical data Starting current cooling A OUTDOOR UNITS RKS20CVMB RKS25CVMB RKS35B/CVMB POWER SUPPLY VM NOMINAL DISTRIBUTION Phase SYSTEM VOLTAGE Frequency Hz 50 Voltage V 230 3D044242B 3D044243B 3D044244B NOTES The sound pressure level is measured in an anechoic room at m distance from the unit. It is a relative value, depending on the distance and acoustic environment. For measuring conditions: please refer to item 8 of this chapter. 2 The sound power level is an absolute value indicating the power which a sound source generates. Split - Sky Air Outdoor Units 3
6 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 2 Specifications 2 TECHNICAL SPECIFICATIONS OUTDOOR UNITS RKS50BVMB9 RKS60BVMB9 RKS7BVMB9 DIMENSIONS Unit H mm 735 W mm 825 D mm 300 WEIGHT kg COLOUR Unit Ivory white SOUND LEVEL Sound pressure () (Cooling) high/low db(a) 47/* 49/* 52/* Sound power (2) (Cooling) high db(a) FAN Air flow rate (Cooling) high/low m3/min 47.7/ / /4.5 Speed (Cooling) high rpm low rpm Model Propeller fan Motor output W 53 HEAT EXCHANGER Type Waffle fin, J 8 Hi-XA tube Rows x stages x fin pitch mm x 32 x.6 2 x 32 x.8 REFRIGERANT CIRCUIT Refrigerant type R-40A Refrigerant charge kg Maximum allowable distance between indoor m and outdoor 30 Maximum allowable level difference m 20 Refrigerant control - COMPRESSOR Type Hermetically sealed swing type Model 2YC32HXD 2YC45BXD Motor output,500,500,900 Oil type FVC50K Oil charge volume! PIPING CONNECTIONS liquid mm φ6.4 gas mm φ2.7 φ5.9 drain mm φ8.0 INSULATION MATERIAL Heat insulation Both liquid and gas pipes * This information was not available at the time of publication. ELECTRICAL SPECIFICATIONS OUTDOOR UNITS RKS50BVMB9 RKS60BVMB9 RKS7BVMB9 CURRENT Nominal running current cooling A Max. running current cooling A Please refer to electrical data Starting current cooling A OUTDOOR UNITS RKS50BVMB9 RKS60BVMB9 RKS7BVMB9 POWER SUPPLY VM VM VM NOMINAL DISTRIBUTION Phase SYSTEM VOLTAGE Frequency Hz Voltage V D04078A 3D040782A 3D040783A NOTES The sound pressure level is measured in an anechoic room at m distance from the unit. It is a relative value, depending on the distance and acoustic environment. For measuring conditions: please refer to item 8 of this chapter. 2 The sound power level is an absolute value indicating the power which a sound source generates. 4 Split - Sky Air Outdoor Units
7 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 2 Specifications ELECTRICAL DATA 2 RKS+FTKS20C unit FTKS20CVMB RKS20CVMB RKS+FTKS25C unit FTKS25CVMB RKS25CVMB RKS+FTKS35C unit FTKS35CVMB RKS35CVMB RKS+FTKS50B unit FTKS50BVMB RKS50BVMB RKS+FTKS60B RKS+FTKS7B unit FTKS60BVMB RKS60BVMB FTKS7BVMB RKS7BVMB RKS+FVKS25B 3D0444 3D0445 3D0446 3D unit FVKS25BVMB RKS25BVMB RKS+FVKS35B unit FVKS35BVMB RKS35BVMB D D D MCA MFA RHz RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency(hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps : Rated motor output (W) NOTES. RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see select Daikin Documentation and select conditional connection, the requested product type and English from the drop down lists, click the search button. Finally, click on the document title of your choice. Split - Sky Air Outdoor Units 5
8 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 2 Specifications 2 ELECTRICAL DATA RKS+FVKS50B unit FVKS50BVMB RKS50BVMB RKS+FLKS25B unit FLKS25BVMB RKS25BVMB RKS+FLKS35B unit FLKS35BVMB RKS35BVMB RKS+FLKS50B unit FLKS50BVMB RKS50BVMB RKS+FFQ25B RKS+FFQ35B unit FFQ25BVB RKS25BVMB D D D D FFQ35BVB RKS35BVMB RKS+FFQ50B RKS+FFQ60B unit FFQ50BVB RKS50BVMB D FFQ60BVB RKS60BVMB D04020 MCA MFA RHz RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency(hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps : Rated motor output (W) NOTES. RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see select Daikin Documentation and select conditional connection, the requested product type and English from the drop down lists, click the search button. Finally, click on the document title of your choice. 6 Split - Sky Air Outdoor Units
9 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 2 Specifications ELECTRICAL DATA 2 RKS+FCQ35B RKS+FCQ50B RKS+FCQ60B unit FCQ35B7V RKS35BVMB FCQ50B7V RKS50BVMB FCQ60B7V RKS60BVMB TW RKS+FHQ35B unit FHQ35BUVB RKS35BVMB RKS+FHQ50B RKS+FHQ60B unit FHQ50BUVB RKS50BVMB D FHQ60BUVB RKS60BVMB D RKS+FBQ35B RKS+FBQ50B RKS+FBQ60B unit FBQ35B7V RKS35BVMB FBQ50B7V RKS50BVMB FBQ60B7V RKS60BVMB TW MCA MFA RHz RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency(hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps : Rated motor output (W) NOTES. RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see select Daikin Documentation and select conditional connection, the requested product type and English from the drop down lists, click the search button. Finally, click on the document title of your choice. Split - Sky Air Outdoor Units 7
10 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 3 Capacity tables 3 RKS+FTKS20C AFR 7.5 BF D044 RKS+FTKS25C AFR 7.5 BF D0442 RKS+FTKS35C AFR 7.5 BF D0443 RKS+FTKS50B AFR.4 BF D SYMBOLS NOTES AFR: Air flow rate (m 3 /min). Ratings shown are net capacities which include a deduction for indoor fan BF: Bypass factor motor heat EWB: Entering wet bulb temp. ( CWB) 2. Shows nominal cooling capacities and power input EDB: Entering dry bulb temp. ( CDB) 3. TC, PI and SHC must be calculated by interpolation using the figures in the TC: Total capacity (kw) above tables. (Figures out of the tables should not be used for calculation.) SHC: Sensible heating capacity (kw) 4. SHC is based on each EWB and EDB PI: Power input (kw) SHC* = SHC correction for other dry bulb SHC* = 0.02 x AFR (m 3 /min) x (-BF) x (DB-EDB) AddSHC*toSHC. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate (AFR) and Bypass factor (BF) are taburated above. 8 Split - Sky Air Outdoor Units
11 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 3 Capacity tables RKS+FTKS60B AFR 6.2 BF D04089 RKS+FTKS7B AFR 6.7 BF D RKS+FVKS25B AFR 8. BF D RKS+FVKS35B AFR 8.3 BF D04039 SYMBOLS NOTES AFR: Air flow rate (m 3 /min). Ratings shown are net capacities which include a deduction for indoor fan BF: Bypass factor motor heat EWB: Entering wet bulb temp. ( CWB) 2. Shows nominal cooling capacities and power input EDB: Entering dry bulb temp. ( CDB) 3. TC, PI and SHC must be calculated by interpolation using the figures in the TC: Total capacity (kw) above tables. (Figures out of the tables should not be used for calculation.) SHC: Sensible heating capacity (kw) 4. SHC is based on each EWB and EDB PI: Power input (kw) SHC* = SHC correction for other dry bulb SHC* = 0.02 x AFR (m 3 /min) x (-BF) x (DB-EDB) AddSHC*toSHC. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate (AFR) and Bypass factor (BF) are taburated above. 3 Split - Sky Air Outdoor Units 9
12 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 3 Capacity tables 3 RKS+FVKS50B AFR 0.8 BF D RKS+FLKS25B AFR 7.6 BF D RKS+FLKS35B AFR 8.6 BF D RKS+FLKS50B AFR.4 BF D SYMBOLS NOTES AFR: Air flow rate (m 3 /min). Ratings shown are net capacities which include a deduction for indoor fan BF: Bypass factor motor heat EWB: Entering wet bulb temp. ( CWB) 2. Shows nominal cooling capacities and power input EDB: Entering dry bulb temp. ( CDB) 3. TC, PI and SHC must be calculated by interpolation using the figures in the TC: Total capacity (kw) above tables. (Figures out of the tables should not be used for calculation.) SHC: Sensible heating capacity (kw) 4. SHC is based on each EWB and EDB PI: Power input (kw) SHC* = SHC correction for other dry bulb SHC* = 0.02 x AFR (m 3 /min) x (-BF) x (DB-EDB) AddSHC*toSHC. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate (AFR) and Bypass factor (BF) are taburated above. 0 Split - Sky Air Outdoor Units
13 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 3 Capacity tables RKS+FFQ25B AFR 9.0 BF D RKS+FFQ35B AFR 0.0 BF D RKS+FFQ50B AFR 2.0 BF D04022 RKS+FFQ60B AFR 5.0 BF D04027 SYMBOLS NOTES AFR: Air flow rate (m 3 /min). Ratings shown are net capacities which include a deduction for indoor fan BF: Bypass factor motor heat EWB: Entering wet bulb temp. ( CWB) 2. Shows nominal cooling capacities and power input EDB: Entering dry bulb temp. ( CDB) 3. TC, PI and SHC must be calculated by interpolation using the figures in the TC: Total capacity (kw) above tables. (Figures out of the tables should not be used for calculation.) SHC: Sensible heating capacity (kw) 4. SHC is based on each EWB and EDB PI: Power input (kw) SHC* = SHC correction for other dry bulb SHC* = 0.02 x AFR (m 3 /min) x (-BF) x (DB-EDB) AddSHC*toSHC. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate (AFR) and Bypass factor (BF) are taburated above. 3 Split - Sky Air Outdoor Units
14 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 3 Capacity tables 3 RKS+FCQ35-60B Outdoor TW SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) NOTES. Ratings shown are net capacities which include a deduction for indoor fan motor heat 2. Shows nominal cooling capacities and power input 3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.) 4. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb SHC* = 0.29 x 60 x AFR (m 3 /min) x (-BF) x (DB-EDB)/860 AddSHC*toSHC. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate and BF are tabulated below. Model FCQ AFR 4 BF 0.6 AFR 5 BF 0.6 AFR 8 BF Split - Sky Air Outdoor Units
15 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 3 Capacity tables RKS+FHQ35B AFR 3 BF D RKS+FHQ50B AFR 3 BF D04060 RKS+FHQ60B AFR 7 BF D SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) NOTES. Ratings shown are net capacities which include a deduction for indoor fan motor heat 2. Shows nominal cooling capacities and power input 3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.) 4. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb SHC* = 0.02 x AFR (m 3 /min) x (-BF) x (DB-EDB) AddSHC*toSHC. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate (AFR) and Bypass factor (BF) are taburated above. Split - Sky Air Outdoor Units 3
16 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 3 Capacity tables 3 RKS+FBQ35-60B Outdoor ; TW252- SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) NOTES. Ratings shown are net capacities which include a deduction for indoor fan motor heat 2. Shows nominal cooling capacities and power input 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb SHC* = 0.29 x 60 x AFR (m 3 /min) x (-BF) x (DB-EDB)/860 AddSHC*toSHC. 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate and BF are tabulated below. Model FCQ AFR.5 BF 0.5 AFR 4 BF 0.5 AFR 9 BF 0. 4 Split - Sky Air Outdoor Units
17 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 4 Dimensional drawings RKS20,25,35C unit (mm) 4 Drain outlet (I.D. J 5.9 hose for connection) 4 x holes for anchor bolts (M8 or M0) Minimum space for air passage Wall height on air outlet side = less than 200 Handle Brand name label Terminal strip with earth terminal Outdoor air thermistor Name plate Wiring inlet Liquid stop valve (J A CuT) Service port In case of removing stop valve cover Gas stop valve (J B CuT) 3D04800 RKS50,60,7B unit (mm) Drain outlet (I.D. J 5.9 hose for connection) Minimum space for air passage Wall height on air outlet side = less than 200 In case of removing stop valve cover 4 x holes for anchor bolts (M8 or M0) Brand name label Name plate Wiring inlet Terminal strip with earth terminal Outdoor air thermistor Model A B RKS50, RKS RKS Indication label (refrigerant) Liquid stop valve (J A CuT) Service port Gas stop valve (J B CuT) 3D034257B Split - Sky Air Outdoor Units 5
18 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 5 Operation range 5 RKS20,25,35C RKS50,60,7B Outdoor temp. ( CDB) Pull-down period Notes: The graph is based on the following conditions:. Equivalent piping length 7.5 m 2. Level difference 0 m 3. Air flow rate high temp. ( CWB) 4D029297C * Possibility to extend the operation range down to -5 C by turning on the switch on the outdoor unit PCB. In this case, the unit will stop operation at -20 C or lower and will recover when temperature rises again. 6 Split - Sky Air Outdoor Units
19 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 6 Piping diagrams RKS20,25C 6 Heat exchanger Outdoor temperature thermistor Heat exchanger thermistor Motor operated valve Muffler with filter Muffler with filter Propeller fan Muffler Four way valve normally: OFF Liquid stop valve Field piping Discharge pipe thermistor Compressor Field piping Accumulator Muffler Gas stop valve Refrigerant flow Cooling 3D RKS35C Heat exchanger Outdoor temperature thermistor Heat exchanger thermistor Motor operated valve Muffler with filter Muffler with filter Propeller fan Four way valve normally: OFF Field piping Liquid stop valve Muffler Discharge pipe thermistor Compressor Accumulator Muffler Gas stop valve Field piping Refrigerant flow Cooling 3D04369 Split - Sky Air Outdoor Units 7
20 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 6 Piping diagrams 6 RKS50B Heat exchanger Outdoor temperature thermistor Capillary tube Heat exchanger thermistor Capillary tube 2 Muffler with filter Refrigerant flow Cooling Capillary tube 3 Propeller fan Filter Motor operated valve Muffler with filter Field piping Discharge pipe thermistor Liquid stop valve Field piping Compressor Accumulator Gas stop valve with service port 3D037835A RKS60,7B Heat exchanger Outdoor temperature thermistor Capillary tube Capillary tube 2 Capillary tube 3 Muffler with filter Refrigerant flow Cooling Heat exchanger thermistor Capillary tube 4 Propeller fan Filter Motor operated valve Muffler with filter Field piping Discharge pipe thermistor Liquid stop valve Field piping Compressor Accumulator Gas stop valve with service port 3D037836A 8 Split - Sky Air Outdoor Units
21 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 7 Wiring diagrams RKS20,25,35C 7 g Field wiring Outdoor NOTE. Refer to the name plate for the power requirements. R : Protective earth C74, C75 C94, C95, C00 : Capacitor DB, DB2 : Diode bridge FU, F2U, F3U : Fuse IC : Solid state relay IPM : Intelligent power module L : Live L : Coil LR : Reactor MC : Compressor motor MF : Fan motor PCB : Printed circuit board MRCW, MRM0, MRM20 : Magnetic relay In case of cooling only type N : Neutral PCB, PCB2 : Printed circuit board QL : Overload protector RT, R2T, R3T, : Thermistor S0, S, S20, S30, S40, S70 S80, S90, S9 HC3, HC4, HL3, HN3 : Connector In case of heat pump type (outdoor) (discharge) (Condenser) SA : Surge arrester ZC, Z2C : Ferrite core V, V2, V3 : Varistor YE : Electronic expansion valve coil YR : Reversing solenoide valve coil XM : Terminal strip 3D042576B RKS50,60,7B To indoor unit Power supply 50Hz V 60Hz V g Field wiring R : Protective earth ZC, Z2C : Ferrite core XM : Terminal strip Y2E : Electronic expansion valve coil V2 V5 : Varistor FU, F2U, FU20 : Fuse HE, HE2, HAC, E, AC, AC2 H, H2, HL L, L2, XA : Connector MRM0, MRM20, MRC/W : Magnetic relay RT R3T S2 S02 LEDA PCB, PCB2 L N SW S4W SA : Thermistor : Connector : Pilot lamp : Printed circuit board : Live : Neutral : Forced operation on/off switch (SW) : Local setting : Surge arrester Outdoor DB MC MF LR QL CT MID SPM (outdoor) (discharge) (Condenser) : Diode bridge : Compressor motor : Fan motor : Reactor : Overload protector : Current transformer : Molded interconnect device : System power module 3D037866D Split - Sky Air Outdoor Units 9
22 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 8 Sound level Sound level data Cooling only Model 230V, 50Hz Cooling Sound pressure level Measuring location Sound power level (cooling) H L RKS20C RKS25C RKS35C RKS50B 47 * 63 RKS60B 49 * 64 RKS7B 52 * 66 * This information was not available at the time of publication. 8-2 Sound pressure spectrum RKS20-25C (Cooling) RKS35C (Cooling) Octave band sound pressure level Octave band sound pressure level approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 4D D04406 Octave band center frequency (Hz) Octave band center frequency (Hz) Legend NOTES Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. 3 Reference acoustic pressure 0dB = 20µPa 50/60Hz, / V 20 Split - Sky Air Outdoor Units
23 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 8 Sound level 8-2 Sound pressure spectrum Cooling only RKS50B RKS60B Octave band sound pressure level Octave band sound pressure level approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 4D027648B Octave band center frequency (Hz) 4D Octave band center frequency (Hz) RKS7B Octave band sound pressure level Legend 50/60Hz, / V approximate threshold hearing for continuous noise 3D027650B Octave band center frequency (Hz) NOTES Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. 3 Reference acoustic pressure 0dB = 20µPa Split - Sky Air Outdoor Units 2
24 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 9 Accessories Standard accessories RKS-C/B Accessories supplied with the outdoor unit: Installation manual 9-2 Optional accessories RKS-C/B RKS20CVMB RKS25CVMB RKS35CVMB RKS50BVMB9 RKS60BVMB9 RKS7BVMB9 Air direction adjustment grille KPW937A4 KPW945A4 22 Split - Sky Air Outdoor Units
25 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 0 Center of gravity RKS20,25,35C 0 4D04407 RKS50,60B The position of foundation bolt 4D Split - Sky Air Outdoor Units 23
26 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB 0 Center of gravity 0 RKS7B The position of foundation bolt 4D042258A 24 Split - Sky Air Outdoor Units
27 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB Installation RKS20,25,35C installation drawings Model 20 / 25 / 35 class Max. allowable length 20 m Max. allowable height 5m Additional refrigerant required for refrigerant pipe exceeding 20 g/m 0 m in length. Gas pipe O.D. 9.5 mm Liquid pipe O.D. 6.4 mm * Be sure to add the proper amount of additional refrigerant. Failure to do so may result in reduced performance. Wrap the installation pipe with the finishing tape from bottom to top 250 mm from wall Service lid How to remove the service lid. + This service lid is an open/close type. + Slide the lid downward to remove it. How to attach the service lid. + Insert the upper part of the service lid into the outdoor unit to install. + Tighten the screws. In sites with poor drainage, use block bases for outdoor unit. Adjust foot height until the unit is leveled. Otherwise, water leakage or pooling of water may occur. Foot bolt-hole centres From unit s side 3 Foot bolt-hole centres Where there is a danger of the unit falling, use foot bolts, or wires. Allow space for piping and electrical servicing. unit (mm) Split - Sky Air Outdoor Units 25
28 Pair Application, Inverter Controlled Unit R-40A RKS CVMB RKS BVMB Installation RKS50,60,7B installation drawings Model 50 class 60 class 7 class Max. allowable length 30m Max. allowable height 20m Additional refrigerant required for refrigerant pipe exceeding 0 m in length. 20 g/m Gas pipe O.D. 2.7 mm O.D. 9.5 mm Liquid pipe O.D. 6.4 mm * Be sure to add the proper amount of additional refrigerant. Failure to do so may result in reduced performance. Wrap the installation pipe with the finishing tape from bottom to top Service lid 250 mm from wall In sites with poor drainage, use block bases for outdoor unit. Adjust foot height until the unit is leveled. Otherwise, water leakage or pooling of water may occur. 580 mm 20 mm 330 mm Foot bolt-hole centres Allow space for piping and electrical servicing. Foot bolt-hole centres From unit s side Where there is a danger of the unit falling, use foot bolts, or wires. 26 Split - Sky Air Outdoor Units
technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air
technical data RXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human
More informationtechnical data air conditioning systems MXS-B Multi Application Split Sky Air
technical data MXS-B Multi Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment
More informationOutdoor Units R-410A ARX-GV1B
Outdoor Units R-40A ARX-GVB t A i n y U k BS r o AV t o0g i d- lt4x pur- SRAO 2 Specifications Outdoor Units R-40A ARX-GVB 2- NOMINAL CAPACITY AND NOMINAL INPUT ARX20GVB ARX25GVB ARX5GVB For combination
More informationtechnical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air
technical data MA-GZ7 Multi Model Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect human health
More informationtechnical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air
technical data RYP-L7/B7 Pair Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the
More informationtechnical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air
technical data FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette Multi (950mm Split Heat x 950mm) Pump (edited) air conditioning systems Split Sky Air Outdoor Units R40A MXS-DAVMB_E2VB_E7VB Features V i
More informationtechnical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air
technical data RQ-B7 Pair/Twin/Triple/Double Twin Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect
More informationSplit-Sky Air RMX-JZ Super Multi Plus
TECHNICAL DATA Split-Sky Air RMX-JZ Super Multi Plus Split Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential
More informationSplit-Sky Air RP-B7 Twin/Triple/Double Twin Application
TECHNICAL DATA Split-Sky Air RP-B7 Twin/Triple/Double Twin Application Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment
More informationSplit-Sky Air FDYP-B7 Concealed Ceiling Unit
TECHNICAL DATA Split-Sky Air FDYP-B7 Concealed Ceiling Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the
More informationSplit-Sky Air FAYP-B Wall Mounted Unit
TECHNICAL DATA Split-Sky Air FAYP-B Wall Mounted Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential
More informationtechnical data air conditioning systems Round Flow Cassette FXFQ-P9VEB
technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................
More informationR410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2
R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1
More information1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units
t i t l r - I Features s e Cs m B ne d E Ue V s 7 ya P os e oc Q dvn S nr ox VF C Reduction of power consumption of 20% (compared to FXSQ-M8 series) through use of new DC fan Improved comfort thanks to
More informationAir Conditioning Technical Data RZQG-L(8)Y1
Air Conditioning Technical Data RZQG-L(8)Y TABLE OF CONTENTS RZQG-L(8)Y Features............................................................. 2 2 Specifications.......................................................
More informationEEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air
EEDEN08-00 technical data FDQ-B8V3B9 air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led
More information19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features
19 Series High-Efficiency Wall-Mounted Ductless systems Performance: Up to 19 SEER 12.5 EER 9.0 HSPF Product Features Inverter Compressor 208/230/1 Power Supply Cooling Range: -4-115 F (with optional wind
More informationAir Conditioning. Technical Data EEDEN RXZ-N
Air Conditioning Technical Data EEDEN14-100 RXZ-N TABLE OF CONTENTS RXZ-N 1 Features............................................................. 2 2 Specifications.......................................................
More informationtechnical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series
technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series Inverter cooling only / heat pump series RSX(Y)P5,8,10K7W1 RSX(Y)P-K7W1 1 Inverter cooling only / heat pump series 1 1 Specifications
More informationtechnical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B
technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems Indoor Units
More information1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units
i r -t i l t - Outdoor Units R-40A RZQ7-40C7VB Features V 7n y CU k 0 S 4 oa o 0 d 7 4Q puz RO S Outdoor units for pair, twin, triple, double twin application The Sky Air Inverter is developed for use
More informationAir Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8
Air Conditioners Technical Data Individual branch selector for VRV heat recovery (Individual BS box) EEDEN11-200 BSVQ100-250P8 Air Conditioners Technical Data Individual branch selector for VRV heat recovery
More informationtechnical data Systems FXMQ-MVE Conceiled ceiling unit (large)
technical data Systems FXMQ-MVE Conceiled ceiling unit (large) FXMQ-MVE 11 Concealed ceiling unit (large) 11 1 Features...2 2 Specifications Technical specifications...3 Electrical specifications...4 Safety
More informationAir Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV
Air Conditioning Technical Data Wall mounted unit EEDEN15-100 FTX-GV TABLE OF CONTENTS FTX-GV 1 Features............................................................. 2 2 Specifications.......................................................
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationAir Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r u n i t E E D E N 2-0 0 RXG-K Outdoor Unit Pair application RXG-K TABLE OF CONTENTS RXG-K Features.............................................................
More informationAir Conditioning. Technical Data EEDEN RXJ-L
ir Conditioning Technical Data EEDEN5-0 RXJ-L Outdoor Unit RXJ-L TLE OF CONTENTS RXJ-L Features............................................................. Specifications.......................................................
More informationAir Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB
Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................
More informationAir Conditioning. Technical Data EEDEN RXZ-N
Air Conditioning Technical Data EEDEN15-100 RXZ-N Outdoor Unit RXZ-N TABLE OF CONTENTS RXZ-N 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning Technical Data RZQSG-L3/9V1
Air Conditioning Technical Data RZQSG-L/9V1 Outdoor Unit RZQSG-L/9V1 TABLE OF CONTENTS RZQSG-L/9V1 1 Features............................................................. 2 2 Specifications.......................................................
More informationWCA4**4. Product Specifications
WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationSplit. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B
Split Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Indoor Unit FTXC-A TABLE OF CONTENTS FTXC-A 1 Features.............................................................
More informationtechnical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air
technical data FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help
More informationR4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,
More informationROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh
ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered
More informationN4A6. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,
More informationR4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors
More informationHeating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps
RZQG71L8Y1B RZQG100L8Y1B RZQG125L8Y1B RZQG140L7Y1B Sound pressure level Heating Nom. dba 50 52 53 53 Cooling Nom. dba 48 50 51 52 Night quiet mode Level 1 dba 43 45 45 45 Standard Accessories Item Tie-wraps
More informationVRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series
VRF Indoor Unit 50Hz Type: Wall Mounted M Series Wall Mounted S Series Contents 01 Wall Mounted M Series 20 Wall Mounted S Series MCAC-VTSM-2016-05 Wall Mounted M Series Wall Mounted M Series 1. Features...
More informationTechnical Service Manual
Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........
More information1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...
MCAC-VTSM-2013-08 1. Features... 264 2. Specifications... 265 3. Dimensions... 268 4. Service Spaces... 272 5. Piping Diagrams... 273 6. Wiring Diagrams... 274 7. Capacity Tables... 276 8. Electrical Characteristics...
More informationProduct Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )
13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation
More informationN4A4 C. Product Specifications
COASTAL 14 SEER AIR CONDITIONER 14 SEER/11.5 12.5 EER R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter drier
More informationCSA6. Product Specifications. SoftSound SXC 2600
16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models
More informationR22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]
R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1
More informationSPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................
More informationCompact Four-way Cassette Type
1. Features... 34 2. Specifications... 35 3. Dimensions... 37 4. Service Spaces... 38 5. Piping Diagrams (EXV beside)... 39 6. Wiring Diagrams... 40 7. Capacity Tables... 41 8. Electrical Characteristics...
More informationProduct Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES
FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system
More informationProduct Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES
FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system
More informationService manual MIV V4+ Indoor units
Service manual MIV V4+ Indoor units Floor Standing MVF22A-VA1 MVF28A-VA1 MVF36A-VA1 MV5A-VA1 MVF56A-VA1 MVF71A-VA1 MVF80A-VA1 MVB22A-VA1 MVB28A-VA1 MVB36A-VA1 MVB45A-VA1 MVB56A-VA1 MVB71A-VA1 MVB80A-VA1
More informationHigh Wall Type ( 2 Series )
Jan.05' Engineering Data High Wall Type ( 2 Series ) Indoor Unit MMK-AP0072H MMK-AP0092H MMK-AP0122H 1. Equipments 2. Technical Specifications 3. Dimensional Drawing 4. Wiring Diagram 5. Refrigerant Cycle
More informationModel RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2
2-8 GENERAL DATA 2.3. INVERTER SERIES 2.3.1. INVERTER (RAS-25YHA2/35YHA3/50YHA2/60YHA2/70YHA2/80YHA2) Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 Power Supply From Outdoor Unit
More informationTSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker
HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationFFQN-C, FCRN-E, FFRN-C
R410A TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FCQN-E, FFQN-C, FCRN-E, FFRN-C Cooling only & Heatpump [50Hz] DAIKIN_FFRN.indb i 12/27/2012 9:28:06 AM DAIKIN_FFRN.indb ii
More informationOperating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16
SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT
More informationR4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT
EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available
More informationFan Coil Units. Technical Data
Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Table of Contents Table of Contents 3 Round Flow Cassette...
More informationProduct Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES
FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system
More informationProduct Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES
Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air
More informationProduct Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits
More informationS/T Ratio. Input BTU/h
SOUND REFRIGERANT ENVIRONMENTALLY PGD3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT, 2½ to 5 TONS 3 Phase, 208/230 3 60 and 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant
More informationTechnical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)
FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-
More informationEngineering Data Book
40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationLow Static Pressure Duct(V shape evaporator)
Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...
More informationTechnical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping
More informationTons BTU/h S.E.E.R* E.E.R** HSPF
SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum
More informationProduct Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil
FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil
More informationIndoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.
Indoor Console Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Black Display Functional art, the touch screen display is elegant
More informationVWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ
PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three
More informationEngineering Data Book
40VMH High Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationSERVICE MANUAL OUTDOOR UNIT. No. OB386
SPLIT-TYPE AIR CONDITIONERS Revision D: MU-A20VB- E and MU-A5VB- E have been added. Please void OB86 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A No. OB86 REVISED EDITION-D Models MU-A20VB-
More informationR4H4. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationProduct Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons
Product Data 38HDL018-060 Cooling Only Condensing Unit 1 1 / 2 to 5 Nominal Tons The 38HDL energy-efficient condensing unit incorporates innovative technology to provide reliable cooling performance. Built
More information6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH
CAE Product Specifications 6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant REFRIGERATION CIRCUIT Copeland scroll compressors on all models with single refrigeration
More informationProduct Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES
LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air
More informationPL Split Indoor Units FTKD25GVM, FTKD35GVM FTKD25GVM4, FTKD35GVM4. Split Outdoor Units RKD50GVM RKD60GVM RKD50GVM4 RKD60GVM4
Split Indoor Units FTKD25GVM, FTKD35GVM FTKD25GVM4, FTKD35GVM4 Split Outdoor Units RKD50GVM RKD60GVM RKD50GVM4 RKD60GVM4 Ceiling Consealed Split - OYL Malaysian Products (for Midle East) FDM30JEVLK, FDYM30JEVLK,
More informationAir Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB
Air Conditioning Technical Data Heat reclaim ventilation EEDEN14-205 VAM-FA/FB Heat reclaim ventilation VAM-FA/FB VAM-FA/FB 1 Features............................................................. 2 2 Specifications.......................................................
More informationLow Static Pressure Duct (V shape evaporator)
MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...
More informationCFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)
ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV
More informationFMU4X, FMC4X FMU4Z, FMC4Z
HORIZONTAL FAN COILS FMU4Z and FMC4Z 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2, 2 1/2, and 3 Tons Horizontal application only Accessory field installed electric heat kits available in 3, 5,
More informationOutdoor Units, 50Hz, R410A
LG AIR CONDITIONERS Outdoor Units, 50Hz, R410A 20 Yoido-dong, Youngdungpo-gu, Yoido P.O.Box 355 Seoul 150-721, Korea Phone: 3777-7969 Fax: 3777-5137/8 http://www.lge.com Approvals: EN ISO 9001 BS EN ISO
More informationCFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available
More informationBAC / BHC Product Specifications
COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves
More informationHCH6. Product Specifications
HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland
More informationOil Cooler AKZ328-D142 PL
Oil Cooler PL-1009-15 1 2 Parts Parts Name Drwg. Parts Model & Specifi cation A1 A 1250093 SWING COMPRESSOR 1YC23HXD 1 M2C A2 0401393 RUBBER BUSH/ LEAD WIRE W443132-2 1 A4 390204 NUT WITH WASHER R4911377-1
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics
More informationV33B High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven
More informationFTXS50EV1B, FTXS60EV1B (RoHS application) FTXS50EV1B, FTXS60EV1B Wiring Diagram
42 FTXS50EV1B, FTXS60EV1B (RoHS application) FTXS50EV1B, FTXS60EV1B Diagram FTXS50EV1B, FTXS60EV1B (RoHS application) 43 44 FTXS50EV1B, FTXS60EV1B (RoHS application) Parts Parts Name Drwg. Parts Model
More informationTSA6. Product Specifications. SmartComfort TXC 5600
ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230
More informationBosch BOVA Split System Heat Pump
Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 03.2018 Bosch Thermotechnology
More informationDESCRIPTION FEATURES
SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at
More informationProduct Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES
Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2013.12 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics
More informationFan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT
Fan Coil Units Technical Data Conceiled ceiling unit ECDEN10-400 FWB-BT Fan Coil Units Technical Data Conceiled ceiling unit ECDEN10-400 FWB-BT TABLE OF CONTENTS FWB-BT 1 Features.............................................................
More information14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/ Single Phase
COMMERCIAL SOUND REFRIGERANT ENVIRONMENTALLY PAD4 Product Specifications 14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/230 1 60 Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A
More informationPHR5. Product Specifications
PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R
More informationSINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU
SINGLE Technical Data Book Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU History Version Modification Date Remark Ver.1.0 Release SINGLE Big
More informationAir Conditioning. Technical Data. Wall mounted unit EEDEN FTXS-K
Air Conditioning Technical Data Wall mounted unit EEDEN3-00 FTXS-K Indoor Unit Wall mounted unit FTXS-K TABLE OF CONTENTS FTXS-K Features............................................................. 2
More information