technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air

Size: px
Start display at page:

Download "technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air"

Transcription

1 technical data FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette Multi (950mm Split Heat x 950mm) Pump (edited) air conditioning systems Split Sky Air

2 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB Features V i 2 nye U_ k BS Mr V o ta oa D i d0- l t S p4u X RS OM Outdoor units for Multi model application. Up to 5 indoor units can be connected to Multi outdoor unit. All indoor units are individually controllable with remote control and do not need to be installed in the same room or at the same time. They operate simultaneously within the same cooling operation It is possible to combine different types of indoor units as well. (e.g. wall mounted, ceiling mounted cassette corner, concealed ceiling unit) Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall. Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency Split Sky Air Outdoor Units

3 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 2 Specifications 2- TECHNICAL SPECIFICATIONS 2MXS4 0DAVMB 2MXS52E2VB MXS52E2VB 4MXS68E2VB 4MXS80E7VB 5MXS90E7VB Casing Colour Ivory White Dimensions Unit Height mm Width mm Depth mm Packing Height mm Width mm Depth mm Weight Unit kg Heat Exchanger Packed Unit kg Dimensions Length mm Nr of Rows Fin Pitch mm Nr of Stages Tube type Hi-Xa(8) ø7.94 grooved tubes 24 ø7.94 grooved tubes 24 Hi-Xa(8) Hi-XSS(8) Hi-XSS(8) Fin Type WF fin Colgate fin Colgate fin WF fin WF fin WF fin Treatment Anti-corrosion treatment (PE) Anti-corrosion treatment (PE) Anti-corrosion treatment (PE) Fan Type Propeller Motor Anti-corrosion treatment (PE) Quantity Air Flow Rate (nominal at 20V) m³/min m³/min Motor Quantity Speed (nominal) Model D50E-28 KFD A KFD A KFD C KFD A KFD A rpm rpm Fan Motor Output W Compressor Quantity Operation Range Sound Level (nominal) Sound Level (Night quiet) Motor Model YC2GXD 2YC6BXD 2YC6BXD 2YC45BXD 2YC6BXD#C 2YC6BXD#C Type Motor Output Hermetically sealed swing compressor W Min CDB Max CDB Min CWB Max CWB Sound Power Sound Pressure Sound Pressure dba dba dba Sound Pressure dba 4 Refrigerant Type R-40A Charge kg Refrigerant Oil Type FVC50K Charged Volume l Split Sky Air Outdoor Units 2

4 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 2 Specifications 2 2- TECHNICAL SPECIFICATIONS 2MXS40DAVMB 2 MXS52E2VB MXS52E2VB 4MXS68E2VB 4MXS80E7VB 5MXS90E7VB Liquid (OD) Quantity Piping connections Standard Accessories Notes Diameter (OD) mm Gas Quantity Diameter (OD) mm Quantity 2 Diameter (OD) mm Quantity 2 2 Diameter (OD) mm Drain Quantity Diameter (OD) mm Piping Length Minimum m.5 (for one room) Additional Refrigerant Charge Installation height difference Max. internunit level difference Heat Insulation Item Maximum m 0 ( for total of each room), 20 (for one room) 50 (for total of each room)/25 (for one room) 50 (for total of each room)/ 25 (for one room) 60 (for total of each room)/ 25 (for one room) 70 (for total of each room)/ 25 (for one room) 75 (for total of each room)/ 25 (for one room) kg/m 0.02/> />0m 0.02/>0m 0.02/>0m 0.02/>0m 0.02/>0m Maximum m 5(between indoor unit and outdoor unit) m 7.5 (between indoor units) 5.0 (between indoor unit and outdoor unit) 7.5 (between indoor units) 5.0 (between indoor unit and outdoor unit) 7.5 (between indoor units) 5.0 (between indoor unit and outdoor unit) 7.5 (between indoor units) Both liquid and gas pipes Installation manual 5.0 (between indoor unit and outdoor unit) 7.5 (between indoor units) 5.0 (between indoor unit and outdoor unit) 7.5 (between indoor units) Quantity pc Item Screw bag Drain plug Drain plug Drain plug Drain plug Drain plug Quantity pc Item Reducer assembly Reducer assembly Reducer assembly Reducer assembly Quantity Reducer assembly Nominal cooling capacities are based on : indoor temperature : 270CDB, 90CWB, outdoor temperature : 50CDB, equivalent refrigerant piping : 7.5m, level difference : 0m. Nominal heating capacities are based on : indoor temperature : 200CDB, outdoor temperature : 70CDB, 60CWB, equivalent refrigerant piping : 7.5m, level difference : 0m Sound levels are measured in an anechoic room Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound level drawings of this chapter. The sound power level is an absolute value indicating the power which a sound source generates. 2-2 ELECTRICAL SPECIFICATIONS 2MXS40DAVMB 2 MXS52E2VB MXS52E2VB 4MXS68E2VB 4MXS80E7VB 5MXS90E7VB Power Supply Name VM V V V V V Current Phase Frequency Hz 50/ Voltage V / Voltage range Minimum V -0% -0% -0% -0% -0% Nominal running current (RLA) Maximum V +0% +0% +0% +0% +0% (A) (A) Starting current (cooling/ heating) A A A Z-max List No requirements Split Sky Air Outdoor Units

5 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 2 Specifications 2-2 ELECTRICAL SPECIFICATIONS 2MXS4 0DAVMB 2MXS52E2VB MXS52E2VB 4MXS68E2VB 4MXS80E7VB 5MXS90E7VB Wiring connections Power Supply Intake For Power Supply For connection with indoor Quantity 4 Quantity Outdoor unit only 2 Split Sky Air Outdoor Units 4

6 Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 240V Indoor temp.: 27 CDB/9.0 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. For more details concerning conditional connections, see select E-Data Books. Finally, click on the document title of your choice. 5 Split Sky Air Outdoor Units

7 Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB MXS52E Model Units Power supply Comp. OFM H/P Outdoor Hz Volts Min. Max. MCA MFA MSC RLA W FLA C/D D MCA MFA MSC RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (See note 6). (A) : MSC means the max. current during the starting of compressor. (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Indoor temp.: 27 CDB/9.0 CWB Outdoor temp. : 5 CDB 2. Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits. Maximum allowable voltage variation between phases is 2% 4. MCA represents maximum input current. MFA represents capacity which may accept MCA 5. Select wire size based on the larger value of MCA. 6. MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker) 7. For more details concerning conditional connections, see select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units 6

8 Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5kW class: wall mounted C series 5.0, 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see select E-Data Books. Finally, click on the document title of your choice. 7 Split Sky Air Outdoor Units

9 Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5kW class: wall mounted C series 5.0, 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units 8

10 Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5kW class: wall mounted C series 5.0, 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see select E-Data Books. Finally, click on the document title of your choice. 9 Split Sky Air Outdoor Units

11 Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5kW class: wall mounted C series 5.0, 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units 0

12 Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D05092-B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5, 5.0kW class: wall mounted D series 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units

13 Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5, 5.0kW class: wall mounted D series 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units 2

14 Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D05092-B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5, 5.0kW class: wall mounted D series 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units

15 Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS68E (50Hz 20V) Combination Units Power supply Comp. OFM IFM Hz Volts Min. Max. MCA MFA RLA W FLA W FLA D B MCA MFA RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Power supply: 50Hz 20V Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 5 CDB Indoor temp.: 20 CDB Outdoor temp.: 7 CDB/6 CWB 2. Maximum allowable voltage unbalance between phases is 2%. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker 5. The above is the value for connecting with the following indoor units. 2.0, 2.5,.5, 5.0kW class: wall mounted D series 6.0kW class: wall mounted B series 6. Be sure to install an earth leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector.) 7. For more details concerning conditional connections, see select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units 4

16 Electrical data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS80E, 5MXS90E Model Units Power supply Comp. OFM H/P Outdoor Hz Volts Min. Max. MCA MFA MSC RLA W FLA C/D D05265 MCA MFA MSC RLA OFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (See note 6). (A) : MSC means the max. current during the starting of compressor. (A) : Rated Load Amps (A) : Outdoor Fan Motor : Full Load Amps (A) : Fan Motor Rated Output (W). RLA is based on the following conditions: Indoor temp.: 27 CDB/9.0 CWB Outdoor temp. : 5 CDB 2. Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits. Maximum allowable voltage variation between phases is 2% 4. MCA represents maximum input current. MFA represents capacity which may accept MCA 5. Select wire size based on the larger value of MCA. 6. MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker) 7. For more details concerning conditional connections, see select E-Data Books. Finally, click on the document title of your choice. 5 Split Sky Air Outdoor Units

17 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4 Options 4MXS, 5MXS N Item 4MXS80E7 5MXS90E7 5MKS90E7 Drain plug KKPJ5F80 4TW Split Sky Air Outdoor Units 6

18 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 6 Dimensional drawing & centre of gravity 6 - Dimensional drawing 6 2MXS40D Drain outlet (I.D. J5.9 hose for connection) 4-cuts for anchor bolts Interconnecting piping and wiring inlet unit (mm) Outdoor air thermistor Brand name label 2-Terminal strip with earth terminal <room A> Liquid stop (J 6.4 Cut) Gas stop (J 9.5 Cut) Minimum space for air passage Wall height on air outlet side = less than 200 Name plate Service port In case of removing stop cover <room B> Liquid stop (J 6.4 Cut) Gas stop (J 9.5 Cut) D099A 2MXS52E unit (mm) 2-cuts for anchor bolts (M8 or M0) Minimum space for air passage Wall height on air outlet side = less than or more A 2- J 2 Hole Liquid J Drain outlet (M8 or M0) DIMENSIONS A Gas J H % (I.D. J5.9 hose for connection) H > Name plate -Terminal strip -Earth terminal Interconnecting piping and wiring inlet Outdoor air thermistor Installation space for discharge side (mm) <room A> (J2.7 single union) <room B> (J2.7 single union) Liquid stop Service port Gas stop D Split Sky Air Outdoor Units

19 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 6 Dimensional drawing & centre of gravity 6 - Dimensional drawing MXS52E unit (mm) 2-cuts for anchor bolts (M8 or M0) Minimum space for air passage Wall height on air outlet side = less than or more 6 Drain outlet (I.D. J5.9 hose for connection) 2- J 2 Hole (M8 or M0) A Liquid J Gas J J DIMENSIONS A H % H > Installation space for discharge side (mm) Name plate 4-Terminal strip 4-Earth terminal Interconnecting piping and wiring inlet Outdoor air thermistor <room A> (J9.5 single union) <room B> (J9.5 single union) <room C> (J2.7 single union) Liquid stop Service port Gas stop D0579 4MXS68E 4-cuts for anchor bolts (M8 or M0) <room A> (J9.5 single union) <room B> (J9.5 single union) Minimum space for air passage Wall height on air outlet side = less than 200 unit (mm) Drain outlet (I.D. J 5.9 hose for connection) 5-Terminal strip with earth terminal <room C> (J2.7 single union) <room D> (J5.9 single union) Name plate Interconnecting piping and wiring inlet Outdoor air thermistor A Liquid J Gas J J Liquid stop Service port Gas stop D0472G Split Sky Air Outdoor Units 90

20 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 6 Dimensional drawing & centre of gravity 6 - Dimensional drawing 4MXS80E Minimum space for air passage unit (mm) 6 4-cuts for anchor bolts Wall height on air outlet side = less than 200 Drain outlet I.D. J 25 hose for connection Name plate Gas stop 5-Terminal strip with earth terminal Liquid stop Outdoor air thermistor A J J J J Interconnecting piping and wiring inlet <room A> (J9.5 single union) <room B> (J2.7 single union) <room C> (J5.9 single union) <room D> (J5.9 single union) D MXS90E unit (mm) 4-cuts for anchor bolts Minimum space for air passage Wall height on air outlet side = less than 200 Drain outlet I.D. J 25 hose for connection Name plate Gas stop 6-Terminal strip with earth terminal Liquid stop Outdoor air thermistor <room A> (J9.5 single union) <room B> (J9.5 single union) <room C> (J2.7 single union) A Liquid J J Gas J J Interconnecting piping and wiring inlet <room D> (J5.9 single union) <room E> (J5.9 single union) D05948A 9 Split Sky Air Outdoor Units

21 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 6 Dimensional drawing & centre of gravity 6-2 Centre of gravity 2MXS40D 6 Anchor bolt 4D04069A 2MXS52E, MXS52E, 4MXS68E Anchor bolt 4D07024H Split Sky Air Outdoor Units 92

22 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 6 Dimensional drawing & centre of gravity 6-2 Centre of gravity 4MXS80E, 5MXS90E 6 Anchor bolt 4D Split Sky Air Outdoor Units

23 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 7 Piping diagram 2MXS40D Outdoor unit Branch pipe Heat exchanger Outdoor temperature thermistor (DOA) Liquid receiver Distributor Liquid receiver Motor operated Motor operated thermistor (DLA) thermistor (DLB) Liquid line stop Liquid line stop (6.4 CuT) (6.4 CuT) Field piping liquid 7 Heat exchanger thermistor(de) Fan motor Propeller fan Reversing solenoid Branch pipe Muffler Muffler (DGA) (DGB) Gas line stop Gas line stop (9.5 CuT) (9.5 CuT) Field piping gas Discharge pipe thermistor (DO) Muffler Muffler Refrigerant flow Compressor Accumulator D0992A 2MXS52E Outdoor unit Header Heat exchanger thermistor (DE) Heat exchanger Outdoor temperature thermistor (DOA) Distributor Header Electronic expansion Electronic expansion thermistor (DLA) thermistor (DLB) Field piping liquid (Liquid side) DC fan motor Capillary tube Liquid line stop Propeller fan Reversing solenoid Header (DGA) Muffler Discharge pipe thermistor (DO) Muffler Muffler (DGB) Field piping gas (Gas side) Refrigerant flow Compressor Accumulator Gas line stop D Split Sky Air Outdoor Units 94

24 7 Piping diagram Outdoor Units R40A MXS-DAVMB_E2VB_E7VB MXS52E Outdoor unit 7 Header Heat exchanger Outdoor temperature thermistor (DOA) Header Electronic expansion Electronic expansion thermistor (DLA) thermistor (DLB) Heat exchanger thermistor (DE) DC fan motor Capillary tube Distributor Liquid line stop Electronic expansion thermistor (DLC) Field piping liquid (Liquid side) Propeller fan Header Reversing solenoid (DGA) Refrigerant flow Muffler Discharge pipe thermistor (DO) Compressor Accumulator Muffler Muffler Gas line stop (DGB) (DGC) Field piping gas (Gas side) D MXS68E Outdoor unit Header Heat exchanger thermistor (DE) DC fan motor Heat exchanger Outdoor temperature thermistor (DOA) Capillary tube Distributor Defrost solenoid Header Liquid line stop Electronic expansion thermistor (DLA) Electronic expansion thermistor (DLB) Electronic expansion thermistor (DLC) Electronic expansion thermistor (DLD) Field piping liquid (Liquid side) Propeller fan Refrigerant flow Reversing solenoid Muffler Discharge pipe thermistor (DO) Compressor Accumulator Accumulator Header Gas line stop (DGA) (DGB) (DGC) (DGD) Field piping gas (Gas side) D045G 95 Split Sky Air Outdoor Units

25 7 Piping diagram Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS80E Outdoor unit Header Heat exchanger Outdoor temperature thermistor Receiver Header Motor operated (A) thermistor (Room-A) Motor operated (B) thermistor (Room-B) 7 Heat exchanger thermistor (Condenser) Motor operated (C) thermistor (Room-C) Field piping liquid Motor operated (D) thermistor (Room-D) Room D DC fan motor Capillary tube Distributor Liquid line stop Motor operated (E) Propeller fan 4-way Header (Room-A) (Room-B) Refrigerant flow Muffler Discharge pipe thermistor Compressor Accumulator Accumulator Gas line stop Muffler Muffler (Room-C) (Room-D) Room D Field piping gas D0597B 5MXS90E Outdoor unit Header Heat exchanger Outdoor temperature thermistor Receiver Header Motor operated (A) thermistor (Room-A) Motor operated (B) thermistor (Room-B) Heat exchanger thermistor (Condenser) Motor operated (C) thermistor (Room-C) Field piping liquid Motor operated (D) thermistor (Room-D) Room D DC fan motor Distributor Motor operated (E) Capillary tube Liquid line stop thermistor (Room-E) Room E Propeller fan 4-way Header (Room-A) (Room-B) Muffler Discharge pipe thermistor (Room-C) (Room-D) Room D Field piping gas Refrigerant flow Compressor Accumulator Accumulator Gas line stop Muffler Muffler (Room-E) Room E D0596A Split Sky Air Outdoor Units 96

26 8 Wiring diagram 8 - Wiring diagram 2MXS40D Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 8 Indoor Power supply 50Hz V 60Hz V g Field wiring Outdoor () () () () (outdoor) (discharge) (condenser) () () Colours BLK: Black / BRN: Brown / WHT: White / RED: Red / BLU: Blue / GRY: Grey / ORG: Orange / YLW: Yellow C5 C8, SHC CT DB, DB FU FU L L LR MC MF MRCW, MRM0, MRM20 N : Capacitor : Current transformer : Diode bridge : Fuse : Live : Coil : Reactor : Compressor motor : Fan motor : Magnetic relay : Neutral OIS : Solid state relay PCB, PCB2 : Printed circuit board QL : Overload protector RT R8T : Thermistor SA : Surge arrester TFU : Thermal fuse TRM : Transistor module V, V2, V : Varistor XM, X2M : Terminal strip YE, Y2E : Electronic expansion coil YR : Reversing solenoide coil ZC : Ferrite core R : Protective earth S0 S2, S20, S2, S0 S40, S45, S70, S80, S90 S92, HL, HL2, HN, HN2, HR, HR4, AC, AC2, HC, HC4, E, X0A : Connector D09565A 2MXS52E Power supply To indoor unit Sheet metal Indoor g Field wiring (outdoor) (discharge) () () () () (condenser) () () Outdoor ZC ZC : Ferrite core XM XM : Terminal strip YE YE : Electronic expansion coil V2,V,V5,V6,V : Varistor SA2 : Surge arrester FU, FU2, FU : Fuse AC, AC2 U, V, W, XA E, E2 HR, HR2 : Connector MRM0, MRM20 MRC/W : Magnetic relay RT R5T R8T, R9T S2 S02 LED LED4 LEDA L N SW S2W SW S4W S5W : Thermistor : Connector : Pilot lamp : Live : Neutral : Forced operation on/off switch (SW) : Select SW (SW2) : Wiring error check SW (SW) : Priority room setting SW (SW4) : Night quiet mode setting SW (SW5) MC MF LR QL PM PCB, 2 YR Sheet metal : Compressor motor : Fan motor : Reactor : Overload protector : Power module : Printed circuit board : Reversing solenoid : Terminal strip fixed plate D Split Sky Air Outdoor Units

27 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 8 Wiring diagram 8 - Wiring diagram MXS52E Power supply 8 To indoor unit Sheet metal Indoor (discharge) () () (outdoor) () () (condenser) () () g Field wiring Outdoor () () ZC ZC : Ferrite core XM X4M : Terminal strip YE YE : Electronic expansion coil V2,V,V5,V6,V : Varistor SA2 : Surge arrester FU, FU2, FU : Fuse AC, AC2 U, V, W, XA E, E2 HR, HR2 : Connector MRM0, MRM20 MRC/W : Magnetic relay RT R6T R8T R0T S2 S02 LED LED4 LEDA L N SW S2W SW S4W S5W : Thermistor : Connector : Pilot lamp : Live : Neutral : Forced operation on/off switch (SW) : Select SW (SW2) : Wiring error check SW (SW) : Priority room setting SW (SW4) : Night quiet mode setting SW (SW5) MC MF LR QL PM PCB, 2 YR Sheet metal : Compressor motor : Fan motor : Reactor : Overload protector : Power module : Printed circuit board : Reversing solenoid : Terminal strip fixed plate D0502-4MXS68E g Field wiring To indoor unit Room D (outdoor) (discharge) () () () () (condenser) () (Room D) () (Room D) () () ZC ZC : Ferrite core XM X5M : Terminal strip YE Y4E : Electronic expansion coil V2 V5 : Varistor FU, FU2, FU20 : Fuse HE, HL, HN E, AC, AC2 H, H2, L L2 : Connector MRM0, MRM20 MRB, MRD MRC/W : Magnetic relay RT R2T S2 S02 HP H5P L N SW S2W SW S4W S5W SA YR : Thermistor : Connector : Pilot lamp : Live : Neutral : Forced operation on/off switch (SW) : Select SW (SW2) : Wiring error check SW (SW) : Priority room setting SW (SW4) : Night quiet mode setting SW (SW5) : Surge arrester : Reversing solenoid YS PCB DB MC MF LR QL CT MID MID2 SPM : Defrost solenoid coil : Printed circuit board : Diode bridge : Compressor motor : Fan motor : Reactor : Overload protector : Current transformer : Molded interconnect device : System power module D042J Split Sky Air Outdoor Units 98

28 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 8 8 Wiring diagram 8 - Wiring diagram 4MXS80E BLK: Black BRN: brown WHT: White RED: Red BLU: Blue GRY: Grey ORG: Orange YLW: Yellow GRN: Green To indoor unit Room D Sheet metal Outdoor Condenser Discharge Room D Room D Indoor Outdoor L: Live, N: Neutral, : Field wiring : Terminal strip : Connector : Connection : Protective earth (screw) : Relay connector : Terminal ZC Z6C XM X5M YE Y4E V2,V,V5 V9,V00 SA2 FU, FU2, FU AC,AC2 U,V,W,XA E,E2E HR,HR2 MRM0, MRM20 MRC/W : Ferrite core : Terminal strip : Electronic expansion coil : Varistor : Surge arrester : Fuse : Connector : Magnetic relay RT RT R4T R7T R8T RT S2 S02 LED LED4 LEDA SW SW2 SW SW4 SW5 MC MF LR : Thermistor : Connector : Light emitting diode : Forced operation on/off switch (SW) : Operation mode sellect SW (SW2) : Wiring error check SW (SW) : Priority room setting SW (SW4) : Night quiet mode setting SW (SW5) : Compressor motor : Fan motor : Reactor QL PM PCB,2 YR Sheet metal F2U QDI : Overload protector : Power module : Printed circuit board : Four way coil : Terminal strip fixed plate : Field fuse : Field earth leakage breaker (00mA) 2TW MXS90E BLK: Black BRN: brown WHT: White RED: Red BLU: Blue GRY: Grey ORG: Orange YLW: Yellow GRN: Green To indoor unit Room D Room E Outdoor Condenser Discharge Room D Room E Room D Room E Indoor Sheet metal Outdoor L: Live, N: Neutral, : Field wiring : Terminal strip : Connector : Connection : Protective earth (screw) : Relay connector : Terminal ZC Z6C : Ferrite core XM X6M : Terminal strip YE Y5E : Electronic expansion coil V2,V,V5 V9,V00 : Varistor SA2 : Surge arrester FU, FU2, FU : Fuse AC,AC2 U,V,W,XA E,E2E HR,HR2 H, H2, L, L2 : Connector MRM0, MRM20 MRC/W : Magnetic relay RT RT R4T R8T R9T RT S2 S02 LED LED5 LEDA SW SW2 SW SW4 SW5 MC MF LR : Thermistor : Connector : Light emitting diode : Forced operation on/off switch (SW) : Operation mode sellect SW (SW2) : Wiring error check SW (SW) : Priority room setting SW (SW4) : Night quiet mode setting SW (SW5) : Compressor motor : Fan motor : Reactor QL PM PCB,2 YR Sheet metal F2U QDI : Overload protector : Power module : Printed circuit board : Four way coil : Terminal strip fixed plate : Field fuse : Field earth leakage breaker (00mA) 2TW Split Sky Air Outdoor Units

29 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 9 Sound data 9 - Sound pressure spectrum 2MXS40D () 2MXS40D () 9 Octave band sound pressure level db:(0db = µ bar) Octave band sound pressure level db:(0db = µ bar) approximate threshold hearing for continuous noise D04067A Legend Octave band center frequency (Hz) Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. Reference acoustic pressure 0dB = 20µPa 50/60Hz, /220-20V D04067A approximate threshold hearing for continuous noise Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. Reference acoustic pressure 0dB = 20µPa Legend Octave band center frequency (Hz) 50/60Hz, /220-20V 4MXS68E () 4MXS68E () Octave band sound pressure level db:(0db = µ bar) Octave band sound pressure level db:(0db = µ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise D04807F Octave band center frequency (Hz) D04807F Octave band center frequency (Hz) Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. The operation noise measuring method is in accordance with JISC962 Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. The operation noise measuring method is in accordance with JISC962 Split Sky Air Outdoor Units 400

30 Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 9 Sound data 9 - Sound pressure spectrum 4MXS80E () 4MXS80E () 9 Octave band sound pressure level db:(0db = µ bar) Octave band sound pressure level db:(0db = µ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise D0520 Octave band center frequency (Hz) D0520 Octave band center frequency (Hz) Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. The operation noise measuring method is in accordance with JISC962 Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. The operation noise measuring method is in accordance with JISC962 5MXS90E () 5MXS90E () Octave band sound pressure level db:(0db = µ bar) Octave band sound pressure level db:(0db = µ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise D05202 Octave band center frequency (Hz) Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. The operation noise measuring method is in accordance with JISC962 D05202 Octave band center frequency (Hz) Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. The operation noise measuring method is in accordance with JISC Split Sky Air Outdoor Units

31 9 Sound data Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 9-2 Sound power spectrum 4MXS80E Octave band sound pressure level db:(0db = µ bar) 5MXS90E Sound power level(db) 9 TW Octave band center frequency (Hz) db(a) = A-weighted sound power level (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 0E-6 µw/m 2 Measured according to ISO 744 TW Octave band center frequency (Hz) dba = A-weighted sound power level (A-scale according to IEC) 2 Refernece acoustic intensity 0dB = 0E-6µW/m_ Measured according to ISO 744 Split Sky Air Outdoor Units 402

32 0 Operation range Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 2MXS40D 0 (50 / 60 Hz) Outdoor temperature ( CDB) Continuous operation Pull-down period Outdoor temperature ( CWB) Continuous operation Indoor temp. ( CWB) Indoor temp. ( CDB) Notes: The graphs are based on the following conditions: d Equivalent piping length 7.5m d Level difference 0m d Air flow rate Hi speed D04065A 2MXS52E, MXS52E, 4MXS68E (50 / 60 Hz) Outdoor temperature ( CDB) Continuous operation Pull-down period Outdoor temperature ( CWB) Continuous operation Indoor temp. ( CWB) Notes: Indoor temp. ( CDB) The graphs are based on the following conditions: d Equivalent piping length 7.5m d Level difference 0m d Air flow rate Hi speed D04956H 40 Split Sky Air Outdoor Units

33 0 Operation range Outdoor Units R40A MXS-DAVMB_E2VB_E7VB 4MXS80E, 5MXS90E (50 / 60 Hz) 0 Outdoor temperature ( CDB) Continuous operation Pull-down period Outdoor temperature ( CWB) Continuous operation Indoor temp. ( CWB) Indoor temp. ( CDB) Notes: The graphs are based on the following conditions: d Equivalent piping length 7.5m d Level difference 0m d Air flow rate Hi speed D05204 Split Sky Air Outdoor Units 404

34 0 Operation range Outdoor Units R40A MXS-DAVMB_E2VB_E7VB Split Sky Air Outdoor Units

technical data air conditioning systems MXS-B Multi Application Split Sky Air

technical data air conditioning systems MXS-B Multi Application Split Sky Air technical data MXS-B Multi Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment

More information

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air technical data RXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human

More information

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air technical data RKS-C RKS-B Pair Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help

More information

Outdoor Units R-410A ARX-GV1B

Outdoor Units R-410A ARX-GV1B Outdoor Units R-40A ARX-GVB t A i n y U k BS r o AV t o0g i d- lt4x pur- SRAO 2 Specifications Outdoor Units R-40A ARX-GVB 2- NOMINAL CAPACITY AND NOMINAL INPUT ARX20GVB ARX25GVB ARX5GVB For combination

More information

Split-Sky Air RMX-JZ Super Multi Plus

Split-Sky Air RMX-JZ Super Multi Plus TECHNICAL DATA Split-Sky Air RMX-JZ Super Multi Plus Split Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential

More information

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................

More information

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air technical data MA-GZ7 Multi Model Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect human health

More information

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units t i t l r - I Features s e Cs m B ne d E Ue V s 7 ya P os e oc Q dvn S nr ox VF C Reduction of power consumption of 20% (compared to FXSQ-M8 series) through use of new DC fan Improved comfort thanks to

More information

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air technical data RQ-B7 Pair/Twin/Triple/Double Twin Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect

More information

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units i r -t i l t - Outdoor Units R-40A RZQ7-40C7VB Features V 7n y CU k 0 S 4 oa o 0 d 7 4Q puz RO S Outdoor units for pair, twin, triple, double twin application The Sky Air Inverter is developed for use

More information

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

Split-Sky Air FDYP-B7 Concealed Ceiling Unit TECHNICAL DATA Split-Sky Air FDYP-B7 Concealed Ceiling Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the

More information

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series Inverter cooling only / heat pump series RSX(Y)P5,8,10K7W1 RSX(Y)P-K7W1 1 Inverter cooling only / heat pump series 1 1 Specifications

More information

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps RZQG71L8Y1B RZQG100L8Y1B RZQG125L8Y1B RZQG140L7Y1B Sound pressure level Heating Nom. dba 50 52 53 53 Cooling Nom. dba 48 50 51 52 Night quiet mode Level 1 dba 43 45 45 45 Standard Accessories Item Tie-wraps

More information

Split-Sky Air FAYP-B Wall Mounted Unit

Split-Sky Air FAYP-B Wall Mounted Unit TECHNICAL DATA Split-Sky Air FAYP-B Wall Mounted Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential

More information

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems Indoor Units

More information

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air technical data RYP-L7/B7 Pair Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the

More information

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air EEDEN08-00 technical data FDQ-B8V3B9 air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led

More information

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features 19 Series High-Efficiency Wall-Mounted Ductless systems Performance: Up to 19 SEER 12.5 EER 9.0 HSPF Product Features Inverter Compressor 208/230/1 Power Supply Cooling Range: -4-115 F (with optional wind

More information

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8 Air Conditioners Technical Data Individual branch selector for VRV heat recovery (Individual BS box) EEDEN11-200 BSVQ100-250P8 Air Conditioners Technical Data Individual branch selector for VRV heat recovery

More information

Air Conditioning Technical Data RZQG-L(8)Y1

Air Conditioning Technical Data RZQG-L(8)Y1 Air Conditioning Technical Data RZQG-L(8)Y TABLE OF CONTENTS RZQG-L(8)Y Features............................................................. 2 2 Specifications.......................................................

More information

technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

technical data Systems FXMQ-MVE Conceiled ceiling unit (large) technical data Systems FXMQ-MVE Conceiled ceiling unit (large) FXMQ-MVE 11 Concealed ceiling unit (large) 11 1 Features...2 2 Specifications Technical specifications...3 Electrical specifications...4 Safety

More information

Air Conditioning Technical Data RZQSG-L3/9V1

Air Conditioning Technical Data RZQSG-L3/9V1 Air Conditioning Technical Data RZQSG-L/9V1 Outdoor Unit RZQSG-L/9V1 TABLE OF CONTENTS RZQSG-L/9V1 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV Air Conditioning Technical Data Wall mounted unit EEDEN15-100 FTX-GV TABLE OF CONTENTS FTX-GV 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning. Technical Data EEDEN RXZ-N

Air Conditioning. Technical Data EEDEN RXZ-N Air Conditioning Technical Data EEDEN14-100 RXZ-N TABLE OF CONTENTS RXZ-N 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................

More information

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Split Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Indoor Unit FTXC-A TABLE OF CONTENTS FTXC-A 1 Features.............................................................

More information

Fan Coil Units. Technical Data

Fan Coil Units. Technical Data Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Table of Contents Table of Contents 3 Round Flow Cassette...

More information

A2P H2P H4P H6P H1P H3P H5P H7P. Outdoor X205A OFF Y1E E1H R6T X5A F8U F7U K14R K2R X28A X6A SEE NOTE 7 HAP X77A X31A X13A X21A P< S1PL P> S1PH

A2P H2P H4P H6P H1P H3P H5P H7P. Outdoor X205A OFF Y1E E1H R6T X5A F8U F7U K14R K2R X28A X6A SEE NOTE 7 HAP X77A X31A X13A X21A P< S1PL P> S1PH RZQSG00L9V N L N 50Hz 0-40V Z5 GRN D089497B WHT HR BRNHR3 PPLHR4 HR + E K0R V3D L N LA FU FU ZF ZF KM Z GRN/YLW Z 5 NA VT VT VD + R VR FU V Z3F Z4 X0A WHT X50A 4 MF MS M3 MS ~ Position of compressor terminal

More information

Air Conditioning. Technical Data EEDEN RXJ-L

Air Conditioning. Technical Data EEDEN RXJ-L ir Conditioning Technical Data EEDEN5-0 RXJ-L Outdoor Unit RXJ-L TLE OF CONTENTS RXJ-L Features............................................................. Specifications.......................................................

More information

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application TECHNICAL DATA Split-Sky Air RP-B7 Twin/Triple/Double Twin Application Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r u n i t E E D E N 2-0 0 RXG-K Outdoor Unit Pair application RXG-K TABLE OF CONTENTS RXG-K Features.............................................................

More information

Air Conditioning. Technical Data EEDEN RXZ-N

Air Conditioning. Technical Data EEDEN RXZ-N Air Conditioning Technical Data EEDEN15-100 RXZ-N Outdoor Unit RXZ-N TABLE OF CONTENTS RXZ-N 1 Features............................................................. 2 2 Specifications.......................................................

More information

technical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air

technical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air technical data FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help

More information

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams... MCAC-VTSM-2013-08 1. Features... 264 2. Specifications... 265 3. Dimensions... 268 4. Service Spaces... 272 5. Piping Diagrams... 273 6. Wiring Diagrams... 274 7. Capacity Tables... 276 8. Electrical Characteristics...

More information

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................

More information

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1

More information

Air Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB

Air Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB Air Conditioning Technical Data Heat reclaim ventilation EEDEN14-205 VAM-FA/FB Heat reclaim ventilation VAM-FA/FB VAM-FA/FB 1 Features............................................................. 2 2 Specifications.......................................................

More information

Technical Service Manual

Technical Service Manual Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........

More information

Compact Four-way Cassette Type

Compact Four-way Cassette Type 1. Features... 34 2. Specifications... 35 3. Dimensions... 37 4. Service Spaces... 38 5. Piping Diagrams (EXV beside)... 39 6. Wiring Diagrams... 40 7. Capacity Tables... 41 8. Electrical Characteristics...

More information

SERVICE MANUAL OUTDOOR UNIT. No. OB387

SERVICE MANUAL OUTDOOR UNIT. No. OB387 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision C: MUH-A25VB - E has been added. Please void OB87 REVISED EDITION-B. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A. OB87 REVISED EDITION-C Wireless type

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASH9LSACW ASH12LSACW Outdoor unit AOH9LSAC AOH12LSAC CONTENTS SPECIFICATIONS...................... 1 DIMENSIONS..........................

More information

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series VRF Indoor Unit 50Hz Type: Wall Mounted M Series Wall Mounted S Series Contents 01 Wall Mounted M Series 20 Wall Mounted S Series MCAC-VTSM-2016-05 Wall Mounted M Series Wall Mounted M Series 1. Features...

More information

SERVICE MANUAL OUTDOOR UNIT. No. OB386

SERVICE MANUAL OUTDOOR UNIT. No. OB386 SPLIT-TYPE AIR CONDITIONERS Revision D: MU-A20VB- E and MU-A5VB- E have been added. Please void OB86 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A No. OB86 REVISED EDITION-D Models MU-A20VB-

More information

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CV3

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CV3 Heating Technical Data Daikin Altherma low temperature split EEDEN2-725 ERLQ-CV Daikin Altherma low temperature split ERLQ-CV TABLE OF CONTENTS ERLQ-CV Features.............................................................

More information

High Wall Type ( 2 Series )

High Wall Type ( 2 Series ) Jan.05' Engineering Data High Wall Type ( 2 Series ) Indoor Unit MMK-AP0072H MMK-AP0092H MMK-AP0122H 1. Equipments 2. Technical Specifications 3. Dimensional Drawing 4. Wiring Diagram 5. Refrigerant Cycle

More information

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 2-8 GENERAL DATA 2.3. INVERTER SERIES 2.3.1. INVERTER (RAS-25YHA2/35YHA3/50YHA2/60YHA2/70YHA2/80YHA2) Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 Power Supply From Outdoor Unit

More information

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with

More information

SkyAir, Packaged Outdoor Units (RoHS application) RQ71KBV4A, RZQ71KBV1, RZQ71KBV4A, RZQ100KBV1 RZQ150HY4A RZQ150KV4A PL-908-1

SkyAir, Packaged Outdoor Units (RoHS application) RQ71KBV4A, RZQ71KBV1, RZQ71KBV4A, RZQ100KBV1 RZQ150HY4A RZQ150KV4A PL-908-1 SkyAir, Packaged Outdoor Units (RoHS application) RQKBV4A, KBV1, KBV4A, 100KBV1 150HY4A 150KV4A PL-908-1 RQKBV4A / KBV1 / KBV4A / 100KBV1 (RoHS application) RQKBV4A / KBV1 / KBV4A / 100KBV1 (RoHS application)

More information

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E SPLIT TYPE AIR CONDITIONER CASSETTE type Models Indoor unit Outdoor unit C24YE MC24Y3E MR24Y3E1 SPECIFICATIONS TYPE COOL & HEAT INDOOR UNIT MC24Y3E OUTDOOR UNIT MR24Y3E1 COOLING CAPACITY 23,500-22,500

More information

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump)

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) PRK 00-04 PREVIEW System OZONE FRIENDLY R-407C Series Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) 3DUW#4 2XWGRRU#8QLWV 111111111111111111111111111111111111111111111111111111111111111111111

More information

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS.

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS. SPLIT-TYPE, AIR CONDITIONERS Revision A: MU-A2YV - E can be connected to MCF-A2WV - E. Please void OB330. SERVICE MANUAL Wireless type Models E MU-A07YV - E MU-A09YV - MU-A2YV - E HFC utilized R40A No.

More information

PRODUCT CODE MODEL NAME. No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty Qty REMARKS

PRODUCT CODE MODEL NAME. No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty Qty REMARKS ERSATZTEILE RAS-4HNC1E, 3~ 400V 50Hz RAS-5HNC1E, 3~ 400V 50Hz RAS-6HNC1E, 3~ 400V 50Hz 1 Rear Cover Assy XEK24870 A E03946 1 1 1 1 1 1 Assembly 1-1 Pipe Cover B 17C86251 A P27003 1 1 1 1 1 1 1-2 Handle

More information

PL-601. SkyAir Connection Units (RoHS application) BSVQ100MAV1, BSVQ160MAV1, BSVQ250MAV1. Air Cleaner (RoHS application) MC707SC, MC757SC, MC757SC-D

PL-601. SkyAir Connection Units (RoHS application) BSVQ100MAV1, BSVQ160MAV1, BSVQ250MAV1. Air Cleaner (RoHS application) MC707SC, MC757SC, MC757SC-D Split Indoor Units (RoHS application) FTKS20D3VML, FTKS20D3VMW, FTKS25D3VML, FTKS25D3VMW FTKS35D3VML, FTKS35D3VMW FTXS20D3VML, FTXS20D3VMW, FTXS25D3VML, FTXS25D3VMW FTXS35D3VML, FTXS35D3VMW FTYN25DAV3B,

More information

Service manual MIV V4+ Indoor units

Service manual MIV V4+ Indoor units Service manual MIV V4+ Indoor units Floor Standing MVF22A-VA1 MVF28A-VA1 MVF36A-VA1 MV5A-VA1 MVF56A-VA1 MVF71A-VA1 MVF80A-VA1 MVB22A-VA1 MVB28A-VA1 MVB36A-VA1 MVB45A-VA1 MVB56A-VA1 MVB71A-VA1 MVB80A-VA1

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

FTXS50EV1B, FTXS60EV1B (RoHS application) FTXS50EV1B, FTXS60EV1B Wiring Diagram

FTXS50EV1B, FTXS60EV1B (RoHS application) FTXS50EV1B, FTXS60EV1B Wiring Diagram 42 FTXS50EV1B, FTXS60EV1B (RoHS application) FTXS50EV1B, FTXS60EV1B Diagram FTXS50EV1B, FTXS60EV1B (RoHS application) 43 44 FTXS50EV1B, FTXS60EV1B (RoHS application) Parts Parts Name Drwg. Parts Model

More information

PL Split Indoor Units FTKD25GVM, FTKD35GVM FTKD25GVM4, FTKD35GVM4. Split Outdoor Units RKD50GVM RKD60GVM RKD50GVM4 RKD60GVM4

PL Split Indoor Units FTKD25GVM, FTKD35GVM FTKD25GVM4, FTKD35GVM4. Split Outdoor Units RKD50GVM RKD60GVM RKD50GVM4 RKD60GVM4 Split Indoor Units FTKD25GVM, FTKD35GVM FTKD25GVM4, FTKD35GVM4 Split Outdoor Units RKD50GVM RKD60GVM RKD50GVM4 RKD60GVM4 Ceiling Consealed Split - OYL Malaysian Products (for Midle East) FDM30JEVLK, FDYM30JEVLK,

More information

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-90EB RO-90EPB C O N T E N T S SPECIFICATIONS... OUTLINE AND DIMENSIONS... CIRCUIT DIAGRAM...5 REFRIGERANT SYSTEM DIAGRAM...6

More information

Oil Cooler AKZ328-D142 PL

Oil Cooler AKZ328-D142 PL Oil Cooler PL-1009-15 1 2 Parts Parts Name Drwg. Parts Model & Specifi cation A1 A 1250093 SWING COMPRESSOR 1YC23HXD 1 M2C A2 0401393 RUBBER BUSH/ LEAD WIRE W443132-2 1 A4 390204 NUT WITH WASHER R4911377-1

More information

Air Conditioners. Technical Data. VRV III heat recovery, with connection to heating only hydrobox REYAQ-P

Air Conditioners. Technical Data. VRV III heat recovery, with connection to heating only hydrobox REYAQ-P Air Conditioners Technical Data VRV III heat recovery, with connection to heating only hydrobox E E D E N 1 1-2 0 0 REYAQ-P Air Conditioners Technical Data VRV III heat recovery, with connection to heating

More information

PL-804. Remote Controller (RoHS application) BRC7F634F, BRC7F635F

PL-804. Remote Controller (RoHS application) BRC7F634F, BRC7F635F Split Indoor Units (RoHS application) FTK20GVLT, FTK25GVLT, FTK30GVLT FTX20GVLT, FTX25GVLT, FTX30GVLT FTKS42GVLT FTXS42GVLT Split Indoor Units (RoHS application) (Revised from PL-802) FTY25GXV1, FTY35GXV1

More information

SERVICE MANUAL MU-GA20VB- MU-GA20VB- MU-GA25VB- MU-GA25VB- MU-GA35VB- E1 OUTDOOR UNIT. No. OB386. Wireless type Models HFC

SERVICE MANUAL MU-GA20VB- MU-GA20VB- MU-GA25VB- MU-GA25VB- MU-GA35VB- E1 OUTDOOR UNIT. No. OB386. Wireless type Models HFC SPLIT-TYPE, AIR CONDITIONERS Revision B: MU-A20VB- E2 and MU-A25VB - have been added. Please void OB86 REVISED EDITION-A. E2 OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A No. OB86 REVISED EDITION-B Wireless

More information

PRODUCT CODE MODEL NAME RASC-10HNPE. No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty REMARKS

PRODUCT CODE MODEL NAME RASC-10HNPE. No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty REMARKS 7E343107 RASC-4HNPE RASC-5HNPE RASC-6HNPE 7E343108 7E343109 No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty REMARKS 1 Foot Assy XEK38712 A E04359 1 1 1 Assembly 1 Foot Assy XEK39008 A E04384 1 1 Assembly

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER ASY9USBCW AOY9UGBC ASY12USBCW AOY12UGBC. Models Indoor unit Outdoor unit

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER ASY9USBCW AOY9UGBC ASY12USBCW AOY12UGBC. Models Indoor unit Outdoor unit SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit Outdoor unit ASY9USBCW AOY9UGBC ASY12USBCW AOY12UGBC CONTENTS SPECIFICATIONS....................... 1 OUTLINE AND DIMENSIONS............

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2013.12 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

Air Conditioning. Technical Data. VRV IV water cooled series EEDEN RWEYQ-T8

Air Conditioning. Technical Data. VRV IV water cooled series EEDEN RWEYQ-T8 Air Conditioning Technical Data VRV IV water cooled series EEDEN15-201 Outdoor Unit TABLE OF CONTENTS 1 Features............................................................. 2 2 Specifications.......................................................

More information

Four-way Cassette Type

Four-way Cassette Type Four-way Cassette Type Four-way Cassette Type 1. Features... 9 2. Specifications... 12 3. Dimensions... 17 4. Service Space... 18 5. Wiring Diagrams... 19 6. Capacity Tables... 21 7. Electric Characteristics...

More information

Fault Codes. J control

Fault Codes. J control J control Timer Temp Fault Codes 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 Enter unit inspection mode by pushing the UP and DOWN buttons simultaneously for two seconds. Ensure that the

More information

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4

More information

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal

More information

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit E10-1 High Static Duct 8, 10HP Digital Inverter Engineering Data Book Indoor Unit RAV-SM2242DT-E RAV-SM2802DT-E RAV-SM2242DT-TR RAV-SM2802DT-TR Outdoor Unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents 1 Specifications..............................................................

More information

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping

More information

Low Static Pressure Duct(V shape evaporator)

Low Static Pressure Duct(V shape evaporator) Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...

More information

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units Universal and Multi Split Units If there is fault on any LG universal or multi unit a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

Engineering Data Book

Engineering Data Book 40VMH High Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book DVM S Eco for America (R410A, 60Hz, HR) Model : AM***NXMDCR/AA History Version Modification Date Remark Ver.1.0 Released DVM S Eco HR for North America TDB 18.02.28 Ver.1. Re 18.0

More information

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit E0--2 High Static Duct 8, 0HP Digital Inverter Engineering Data Book Indoor Unit RAV-SM2242DT-E RAV-SM2802DT-E RAV-SM2242DT-TR RAV-SM2802DT-TR Outdoor Unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents Specifications..............................................................

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

SINGLE. Technical Data Book. HSP Duct for America (R410A, 60Hz, H/P)

SINGLE. Technical Data Book. HSP Duct for America (R410A, 60Hz, H/P) SINGLE Technical Data Book HSP Duct for America (R41A, 6Hz, H/P) Version Modification Date Remark Ver.1.4 Modified MCA 16.3.8 Ver.1.5 Modified Specifcation for MCA, Compressor oil type, Capacity Table,

More information

AIR-CONDITIONER SERVICE MANUAL. RBM-Y1034F-PE (3-way) 3-PIPE SUPER MULTI, HEAT PUMP WITH SIMULTANEOUS HEATING AND COOLING. RBM-Y1044F-PE (4-way)

AIR-CONDITIONER SERVICE MANUAL. RBM-Y1034F-PE (3-way) 3-PIPE SUPER MULTI, HEAT PUMP WITH SIMULTANEOUS HEATING AND COOLING. RBM-Y1044F-PE (4-way) FILE NO. A90-9922 SERVICE MANUAL AIR-CONDITIONER Outdoor Unit Multi Controller 2-PIPE SUPER MULTI, HEAT PUMP MAR-M104HTM8-PE RBM-Y1034-PE (3-way) RBM-Y1044-PE (4-way) 3-PIPE SUPER MULTI, HEAT PUMP WITH

More information

Engineering Data Book

Engineering Data Book 40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors

More information

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) SINGLE Technical Data Book 4Way Cassette S for Nordic (R4A, 5Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) History Version Modification Date Remark Ver.1. Released SINGLE for Nordic TDB 15.3.. Ver.1.1

More information

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE Indoor unit AGYF09LAC AGYFLAC AGYFLAC AGYFLAC Outdoor unit AOYV09LAC AOYVLAC AOYVLAC AOYVLAL CONTENTS SPECIFICATIONS..................... DIMENSIONS.........................

More information

Digital Inverter 4 series

Digital Inverter 4 series TCTC-E14-LC005-2 Digital Inverter 4 series Outdoor Unit RAV-SM304ATP-E RAV-SM304ATJP-E RAV-SM4ATP-E RAV-SM4ATJP-E I ndoor Unit RAV-SM307KRTP-E RAV-SM7KRTP-E RAV-SM7CTP-E RAV-SM304MUT-E RAV-SM4MUT-E RAV-SM304SDT-E

More information

CASSETTE type SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS

CASSETTE type SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS SPLIT TYPE AIR CONDITIONER CASSETTE type Models Indoor unit Outdoor unit AUU8RC AUU4RC AOU8RC AOU4RC CONTENTS SPECIFICATIONS........................................ OUTLINE AND DIMENSIONS..............................

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units Universal and Multi Split Units If there is a fault on any LG Universal or Multi unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller

More information

SERVICE MANUAL MUH-GA25VB - E1 MUH-GA25VB - MUH-GA35VB - E1 HFC. Wireless type Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. OB387 R410A CONTENTS

SERVICE MANUAL MUH-GA25VB - E1 MUH-GA25VB - MUH-GA35VB - E1 HFC. Wireless type Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. OB387 R410A CONTENTS SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models E MUH-GA20VB - E MUH-GA25VB - MUH-GA35VB - E HFC utilized R40A. OB387 CONTENTS Indication of model name MUH-GA20VB - E MUH-GA25VB

More information

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU SINGLE Technical Data Book Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU History Version Modification Date Remark Ver.1.0 Release SINGLE Big

More information

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,

More information

SERVICE MANUAL MUH-GA20VB- MUH-GA20VB- MUH-GA25VB- MUH-GA25VB- MUH-GA35VB- E1 OUTDOOR UNIT. No. OB387. Wireless type Models HFC

SERVICE MANUAL MUH-GA20VB- MUH-GA20VB- MUH-GA25VB- MUH-GA25VB- MUH-GA35VB- E1 OUTDOOR UNIT. No. OB387. Wireless type Models HFC SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision A: MUH-A20VB- E2 and MUH-A25VB - have been added. Please void OB87. E2 OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A. OB87 REVISED EDITION-A Wireless type

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9

More information

WCA4**4. Product Specifications

WCA4**4. Product Specifications WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

Low Static Pressure Duct (V shape evaporator)

Low Static Pressure Duct (V shape evaporator) MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...

More information

CDK25JVEC, CDK35JVEC, CDX25BVMC, CDX25BVMC9, CDX25JVEC, CDX35BVMC, CDX35BVMC9, CDX35JVEC, CDX50AVMC9, CDX60AVMC9 CDK35HAVER1, CDK60HAVER1

CDK25JVEC, CDK35JVEC, CDX25BVMC, CDX25BVMC9, CDX25JVEC, CDX35BVMC, CDX35BVMC9, CDX35JVEC, CDX50AVMC9, CDX60AVMC9 CDK35HAVER1, CDK60HAVER1 Split, Multi Type Room Air Conditioner Split Indoor Units CDK25JVEC, CDK35JVEC, 25BVMC, 25BVMC9, 25JVEC, 35BVMC, 35BVMC9, 35JVEC, 50AVMC9, 60AVMC9 CDK35HAVER1, CDK60HAVER1 Packeged Type Air Conditioner-Indoor

More information

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors

More information