Split-Sky Air RMX-JZ Super Multi Plus

Size: px
Start display at page:

Download "Split-Sky Air RMX-JZ Super Multi Plus"

Transcription

1 TECHNICAL DATA Split-Sky Air RMX-JZ Super Multi Plus

2 Split Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe NV is approved by LRQA for its Quality Management System in accordance with the ISO900 standard. ISO900 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin Europe NV is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. Specifications are subject to change without prior notice DAIKIN PRODUCTS ARE DISTRIBUTED BY : Internet Zandvoordestraat 300, B-8400 Oostende Prepared in Belgium by Goekint Graphics 09/200

3 Super Multi Plus R-407C RMX40JZ TABLE OF CONTENTS RMX-JZ Features Specifications... 3 Technical specifications Electrical specifications 3 Combination table Capacity tables Dimensional drawings Operation range Piping diagrams Wiring diagrams Sound level Sound level data Sound pressure spectrum 0 Accessories Standard accessories Optional accessories Centre of gravity Installation Split - Sky Air Outdoor Units

4 Super Multi Plus R-407C RMX40JZ Features + The RMX gives you a high-capacity multi split system which combines the power and easy installation of a VRV outdoor unit with the quiet operation of residential - use indoor units. + The Super Multi Plus has more than enough power to drive up to 7 indoor units, including a 7. kw class unit. + An inverter driven air conditioner has the capacity to provide full power in all rooms at the same time, yet is also energy saving. + A 5-meter piping length means there are now no restrictions on the choice of installation position for indoor units, greatly improving planning flexibility. 2 Split - Sky Air Outdoor Units

5 Super Multi Plus R-407C RMX40JZ 2 Specifications TECHNICAL SPECIFICATIONS OUTDOOR UNITS RMX40JZVMB DIMENSIONS Unit H mm,345 W mm 880 D mm 320 WEIGHT Unit kg 36 MATERIAL Unit - COLOUR Unit Ivory white SOUND LEVEL Sound pressure () high dba 53/53 Cooling/heating low dba - Sound power (2) dba - FAN Air flow rate high m 3 /min 4 low m 3 /min 04 Type Propeller Qty x model 2 x D90A-37 Qty x motor output (Upper side / lower side) H W x53/x4 L W x38/x30 HEAT EXCHANGER Type WF FIN, J8 ONHI-XA tube (anti-corrosion treatment) Rows x stages x fin pitch mm 2 x 60 x 2 Face area m 2 - REFRIGERANT CIRCUIT Refrigerant type R-407C Refrigerant charge kg 9.9 Number of circuits - COMPRESSOR Type Hermetically sealed scroll type (Oval discharge) Qty x model x JT00FAVD No. of cylinders - Speed H rpm 775/75 (Upper side / lower side) L rpm 700/650 Oil type DAPHNE FVC68D Oil charge volume!.5 Crankcase heater W - PIPING CONNECTIONS liquid mm φ9.5 (flare) gas mm φ9. (flare) drain mm φ8 INSULATION MATERIAL Heat insulation Both liquid and gas pipes 2 Split - Sky Air Outdoor Units 3

6 Super Multi Plus R-407C RMX40JZ 2 Specifications 2 ELECTRICAL SPECIFICATIONS OUTDOOR UNITS CURRENT RMX40JZVMB Nominal running current H A 0.50/0.47 (Upper side / lower side) L A 0.45/0.42 Starting current cooling A 29.0 heating A 29.0 OUTDOOR UNITS POWER SUPPLY NOMINAL DISTRIBUTION SYSTEM VOLTAGE RMX40JZVMB V Phase Frequency Hz 50 Voltage V 220/240 NOTES The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment. 2 The sound power level is an absolute value indicating the power which a sound source generates. 3 Maximum allowable distance between indoor and outdoor unit: 5m (total main piping and branch piping), 55m (total main piping), 60m (total branch piping), 5m (max. length for each room). Maximum allowable level difference: 30m (between indoor or BP unit and outdoor unit), 5m (between indoor units and BP units). 4 No additional refrigerant charge 4 Split - Sky Air Outdoor Units

7 Super Multi Plus R-407C RMX40JZ 2 Specifications TECHNICAL SPECIFICATIONS For branch providers only: BRANCH PROVIDER BPMK928B42 BPMK928B43 CONNECTABLE INDOOR UNITS 2 2 NOMINAL INPUT kw 0 0 DIMENSIONS Unit H mm W mm D mm WEIGHT kg 7 8 COLOUR Unit - - NUMBER OF WIRING CONNECTIONS 4 for Interunit wiring RUNNING CURRENT A MAX. COMBINATION kw MIN. COMBINATION kw PIPING CONNECTIONS liquid mm Main: φ9.5 x /Branch: φ6.4 x 2 Main: φ9.5 x /Branch: φ6.4 x3 gas mm Main: φ9. x /Branch: φ5.9 x 2 Main: φ9. x /Branch: φ5.9 x3 drain mm Drain processingless INSULATION MATERIAL Heat insulation tape Both liquid and gas pipes 2 ELECTRICAL SPECIFICATIONS Branch providers BPMK928B42 BPMK928B43 CURRENT Nominal running current A Branch providers POWER SUPPLY V V NOMINAL DISTRIBUTION SYSTEM VOLTAGE Phase Frequency Hz Voltage V NOTES BP or indoor unit max. height - BP or indoor unit min. Height max. 5m. Set up BP and IU in 5m. 2 The piping connection must be cut so as to suit the piping sizes of the indoor unit which will be connected. The same sizes should be used for the piping on the outdoor unit. Split - Sky Air Outdoor Units 5

8 Super Multi Plus R-407C RMX40JZ 2 Specifications 2 ELECTRICAL DATA RMX40JZVMB Unit Comp. Comp. OFM Model Type Hz-volts Voltage range Min. Max. MCA MFA MSC RLA kw FLA RMX40JZVMB VM V D MCA MFA MSC RLA OFM FLA kw SYMBOLS : Min. Circuit Amps : Max. Fuse Amps : Max. Starting Current : Rated Load Amps (A) : Outdoor Fan Motor : Full Load Amps : Fan Motor Rated Output NOTES RLA is based on the following conditions: Indoor temperature 27 CDB/9 CWB Outdoor temperature 35 CDB 2 MSC means the max. current during the starting of compressor. 3 Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits 4 Maximum allowable voltage variation between phases is 2% 5 MCA/MFA MCA =.25 x max. RLA + other RLA + ea. FLA MFA <= 2.25 x max. RLA + other RLA + ea. FLA (Next lower standard fuse rating. Min. 5A) 6 Select wire size based on the larger value of MCA. 7 MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). The relationship between the starting time and the starting current Starting current Starting time 3D Split - Sky Air Outdoor Units

9 Super Multi Plus R-407C RMX40JZ 3 Combination table Indoor unit capacity FTX(D), CDX FTXD FLX FVX Type Rated capacity (kw) Indoor unit capacity FHYC FHYB Type Rated capacity (kw) Combination capacity index The rated capacities above show the rise in indoor unit connection capacity when operating frequency is constant. Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values. A: Capacity or power consumption The A of each indoor unit = The A calculated on the table above x the rated A of each indoor unit The total rated A of the indoor units Comparison of cooling capacity Comparison of heating capacity Cooling capacity (R-407C) Cooling (R-407C) Heating capacity (R-407C) Heating (R-407C) Cooling capacity (kw) Cooling power consumption (kw) Heating capacity (kw) Heating power consumption (kw) Total connection capacity (kw) Total connection capacity (kw) NOTES Cooling capacity is based on 27 CDB / 9 CWB (indoor temperature), 35 CDB (outdoor temperature). Heating capacity is based on 20 CDB (indoor temperature), 7 CDB/6 CWB (outdoor temperature). The rated capacities above show the rise in indoor unit connection capacity when operating frequency is constant. Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values. Split - Sky Air Outdoor Units 7

10 Super Multi Plus R-407C RMX40JZ 3 Combination table 3 RMX40JZ Indoor unit combination capacity (R-407C) RMX40JZ Total indoor unit Capacity (kw) Power consumption (kw) COP capacity (kw) Cooling capacity (R-407C) Heating capacity (R-407C) Cooling (R-407C) Heating (R-407C) Cooling Heating NOTES Cooling capacity is based on 27 CDB / 9 CWB (indoor temperature), 35 CDB (outdoor temperature). Heating capacity is based on 20 CDB (indoor temperature), 7 CDB/6 CWB (outdoor temperature). The rated capacities above show the rise in indoor unit connection capacity when operating frequency is constant. Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values. 8 Split - Sky Air Outdoor Units

11 Super Multi Plus R-407C RMX40JZ 3 Combination table RMX40JZ Total indoor unit Capacity (kw) Power consumption (kw) COP capacity (kw) Cooling capacity (R-407C) Heating capacity (R-407C) Cooling (R-407C) Heating (R-407C) Cooling Heating NOTES Cooling capacity is based on 27 CDB / 9 CWB (indoor temperature), 35 CDB (outdoor temperature). Heating capacity is based on 20 CDB (indoor temperature), 7 CDB/6 CWB (outdoor temperature). The rated capacities above show the rise in indoor unit connection capacity when operating frequency is constant. Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values. Split - Sky Air Outdoor Units 9

12 Super Multi Plus R-407C RMX40JZ 4 Capacity tables 4 Indoor/outdoor temperature compensation Cooling capacity (50Hz-230V) Combination % 30% (8.9kW) 20% (7.5kW) 0% (6.0kW) Outdoor Indoor air temp.: CWB CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw kw kw TC: Total capacity (kw) PI: Power input (kw) 0 Split - Sky Air Outdoor Units

13 Super Multi Plus R-407C RMX40JZ 4 Capacity tables Combination % 00% (4.5kW) 90% (3.kW) 80% (.6kW) Outdoor Indoor air temp.: CWB CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw kw kw TC: Total capacity (kw) PI: Power input (kw) Split - Sky Air Outdoor Units

14 Super Multi Plus R-407C RMX40JZ 4 Capacity tables 4 Combination % 70% (0.2kW) 60% (8.7kW) 5.7% (7.5kW) Outdoor Indoor air temp.: CWB CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw kw kw TC: Total capacity (kw) PI: Power input (kw) 2 Split - Sky Air Outdoor Units

15 Super Multi Plus R-407C RMX40JZ 4 Capacity tables Indoor/outdoor temperature compensation Heating capacity Combination % 30% (8.9kW) 20% (7.4kW) 0% (6.0kW) TC: Total capacity (kw) PI: Power input (kw) Outdoor Indoor air temp.: CWB CDB TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw Split - Sky Air Outdoor Units 3

16 Super Multi Plus R-407C RMX40JZ 4 Capacity tables 4 Combination % 00% (4.5kW) 90% (3.kW) 80% (.6kW) Outdoor Indoor air temp.: CWB CDB TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw TC: Total capacity (kw) PI: Power input (kw) 4 Split - Sky Air Outdoor Units

17 Super Multi Plus R-407C RMX40JZ 4 Capacity tables Combination % 70% (0.2kW) 60% (8.7kW) 5.7% (7.5kW) Outdoor Indoor air temp.: CWB CDB TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw TC: Total capacity (kw) PI: Power input (kw) Split - Sky Air Outdoor Units 5

18 Super Multi Plus R-407C RMX40JZ 4 Capacity tables 4 Capacity correction factor by the length of refrigerant piping (Reference) Rate of change in capacity by the main piping length Rate of change in cooling capacity Main piping length Rate of change in cooling capacity 00.0% 98.2% 96.4% 94.6% 92.8% 9.0% 89.2% 87.4% 85.6% 83.8% 82.0% Rate of change in heating capacity Main piping length Rate of change in cooling capacity 00.0% 99.5% 99.0% 98.5% 98.0% 97.5% 97.0% 96.5% 96.0% 95.5% 95.0% + Rate of change in capacity by the main piping length F Rate of change in cooling capacity Rate of change in heating capacity Rate of change in capacity % Main piping length (m) In both cases, the outdoor unit is in inferior or superior position for the indoor unit, the rate of change in capacity is the same. Rate of change in capacity by the branch piping length Room air conditioner 25 class Room air conditioner class, sky air 35 class Piping length Cooling Heating % 00.0% % 99.4% % 97.9% % 96.4% Piping length Cooling Heating % 00.0% % 99.6% % 98.6% % 97.5% Sky air class Piping length Cooling Heating % 00.0% % 99.8% % 99.3% % 98.9% 6 Split - Sky Air Outdoor Units

19 Super Multi Plus R-407C RMX40JZ 4 Capacity tables RA25 class rate of change in capacity by branch piping length Cooling Heating 4 Rate of change in capacity % Branch piping length (m) RA class SA35 class rate of change in capacity by branch piping length Cooling Heating Main piping length% Branch piping length (m) SA class rate of change in capacity by branch piping length Cooling Heating Rate of change in capacity% Branch piping length (m) Method of calculating cooling / heating capacity: Total capacity from capacity tables x (Rate of change in capacity by main piping length x rate of change in capacity by branch piping length). Split - Sky Air Outdoor Units 7

20 Super Multi Plus R-407C RMX40JZ 5 Dimensional drawings 5 RMX40JZ 4-u notching hole (form 2) unit (mm) (for foundation bolt) Note: The horizontal coupling and stacking are not allowed. Manufacturer s label Knock out hole for bottom piping Gas side piping fitting port (stop valve) J9. flare connection 2 Liquid side piping fitting port (stop valve) J9.5 flare connection 3 Earth wire in-controle box 4 Refrigerant piping intake 5 Power supply wiring intake (knock hole J34) 6 Control wire intake J27 knock out hole 7 Outside diameter J26 3 locations 3D024685A BPMK928B42 unit (mm) (Characteristic 3.) 2-O.D.J5.9Cut 2-I.D.J6.4Cut 4-suspension bolts (M8 M0) I.D.J9.5Cut I.D.J9.Cut Standard accessories For branch piping (Gas) Cut line for A Dimple (Precaution 5.) For main piping (Gas) For branch piping (Liquid) 2 x 2-Brazing Suspension bolt pitch Branch piping Room A Room B Suspension bolt pitch Collective indication label Wiring clamp Electric box Terminal Main piping I.D.J9.5 Cut line for I.D. J 5.9 Cut line for I.D. J 2.7 Cut line Installation restrictions (Installation and service space) (servicing space) I.D.J9.5 Indication label (for indoor unit) Wiring clamp Earth terminal Indication label (for outdoor unit) 2-Brazing Manufacturer s label Wall mounted (Characteristic 3.) Characteristic:. No drain treatment necessary. 2. This unit may be installed with sides F or R facing forward (servicing direction). 3. The piping for the indoor unit may be freely led around in directions A, B or C. 4. This unit may be installed suspended from the ceiling or mounted on the wall. (However, the hooks must be replaced when mounting on the wall.) Precaution. Be sure to install unit so that side D is facing up. 2. The inclination of side D must be within ±5 degrees forward or back or to the sides. 3. When mounting on the wall, modify the position of the hooks so that the unit is secured in three places. 4. When applying wax to the pipes, be sure to protect the main unit s piping with a cloth. 5. Cut the piping on the standard accessories to match the indoor unit s piping diameter. 6. This unit is for indoor use. (If installing outdoors, place in a location away from wind and rain.) Inspection opening Be sure to leave a 600mm square opening for service and maintenance. 3D024827B 8 Split - Sky Air Outdoor Units

21 Super Multi Plus R-407C RMX40JZ 5 Dimensional drawings BPMK928B43 unit (mm) 5 (Characteristic 3.) 3-O.D.J5.9Cut 3-I.D.J6.4Cut 4-suspension bolts (M8 M0) I.D.J9.5Cut I.D.J9.Cut Standard accessories For branch piping (Gas) Cut line for A Dimple (Precaution 5.) For main piping (Gas) For branch piping (Liquid) 2x3-Brazing Suspension bolt pitch Branch piping Room A Room B Room C Collective indication label Suspension bolt pitch Wiring clamp Electric box Terminal Main piping I.D.J9.5 Cut line for I.D. J 5.9 Cut line for I.D. J 2.7 Cut line Installation restrictions (Installation and service space) (servicing space) I.D.J9.5 Indication label (for indoor unit) Wiring clamp Earth terminal Indication label (for outdoor unit) 2-Brazing Manufacturer s label Wall mounted (Characteristic 3.) Characteristic:. No drain treatment necessary. 2. This unit may be installed with sides F or R facing forward (servicing direction). 3. The piping for the indoor unit may be freely led around in directions A, B or C. 4. This unit may be installed suspended from the ceiling or mounted on the wall. (However, the hooks must be replaced when mounting on the wall.) Precaution. Be sure to install unit so that side D is facing up. 2. The inclination of side D must be within ±5 degrees forward or back or to the sides. 3. When mounting on the wall, modify the position of the hooks so that the unit is secured in three places. 4. When applying wax to the pipes, be sure to protect the main unit s piping with a cloth. 5. Cut the piping on the standard accessories to match the indoor unit s piping diameter. 6. This unit is for indoor use. (If installing outdoors, place in a location away from wind and rain.) Inspection opening Be sure to leave a 600mm square opening for service and maintenance. 3D024826B Split - Sky Air Outdoor Units 9

22 Super Multi Plus R-407C RMX40JZ 6 Operation range 6 RMX40JZ Cooling Heating Outdoor temp. ( CDB) Continuous operation Pull-down period Outdoor temp. ( CWB) Continuous operation Indoor temp. ( CWB) Indoor temp. ( CDB) Notes: The graphs are based on the following conditions: + Equivalent piping length From outdoor unit to BP unit 3 m Total from BP unit to indoor unit 5 m + Level difference 0 m + Air flow rate high 3D027606A 20 Split - Sky Air Outdoor Units

23 Super Multi Plus R-407C RMX40JZ 7 Piping diagrams RMX40JZ Outdoor unit 7 Distributor Outdoor temperature thermistor (DOA) Electronic expansion valve Electronic expansion valve Capillary tube Check valve Capillary tube Check valve Liquid line stop valve Field piping (9.Cut) Fan motor Receiver Propeller fan Heat exchanger thermistor (DE) 4-way valve Gas line stop valve Fan motor Header Capillary tube Field piping (9.Cut) Propeller fan Oil separator High pressure switch Suction pipe thermistor (DS) Liquid pipe thermistor (DEL) Heat exchanger Refrigerant flow Heating Heating Discharge pipe thermistor Compressor Low pressure sensor Electronic expansion valve Accumulator Flexible tube 3D024920B BPMK928B42 Indoor unit Gas side thermistor (DGA) Room A (5.9Cut) Refrigerant flow Cooling Heating Gas side thermistor (DGB) Room B (5.9Cut) Gas Electronic expansion valve (Bypass factor) Electronic expansion valve (Room A) Liquid side thermistor (DGA) Indoor unit Room A (6.4Cut) Outdoor unit (9.Cut) Electronic expansion valve (Room B) Liquid side thermistor (DGB) Room B (6.4Cut) Liquid Outdoor unit (9.5Cut) Notes:. Brazing for the field piping connection. 2. Use the pipe attached if the pipe size is not matched when connecting indoor unit. * Adjustable for the connecting direction. 3D024825A Split - Sky Air Outdoor Units 2

24 Super Multi Plus R-407C RMX40JZ 7 Piping diagrams 7 BPMK928B43 Indoor unit Gas side thermistor (DGA) Room A (5.9Cut) Refrigerant flow Cooling Heating Gas side thermistor (DGB) Gas side thermistor (DGC) Room B (5.9Cut) Room C (5.9Cut) Gas Electronic expansion valve (Bypass factor) Indoor unit Electronic expansion valve (Room A) Liquid side thermistor (DGA) Room A (6.4Cut) Outdoor unit (9.Cut) Electronic expansion valve (Room B) Electronic expansion valve (Room C) Liquid side thermistor (DGB) Liquid side thermistor (DGC) Room B (6.4Cut) Room C (6.4Cut) Liquid Outdoor unit (9.5Cut) Notes:. Brazing for the field piping connection. 2. Use the pipe attached if the pipe size is not matched when connecting indoor unit. * Adjustable for the connecting direction. 3D024824A 22 Split - Sky Air Outdoor Units

25 Super Multi Plus R-407C RMX40JZ 8 Wiring diagrams RMX40JZ Active module 8 Power supply 50Hz 230V To BP unit g Field wiring ACN ACP CR C9000-C927 CT900-CT902 FU FG-FG3 H02-H05 HP-H4P HPS PM L L900-L904 LR, L2R LED2-LED4 MC MF, M2F N OIS5 PCB-PCB4 : Connector : Connector : Capacitor : Capacitor : Current transformer : Fuse : Protective earth : Wire harness : Pilot lamp : High pressure switch : Power module : Live : Coil : Reactor : 7 segment : Compressor motor : Fan motor : Neutral : Solid state relay : Printed circuit board R250,R25 RT, R2T RY3X, RY84 S0-S952 SW-SW2 SW3 SW4 SW5 SW6 SW7 SA900 SP V900-V90 TA5, TA6 TB2-TB8 XM, X4M YE-Y3E YR ZC-Z6C : Resistor : Thermistor : Magnetic relay : Connector : Address sellect SW : Operation mode sellect SW : Pump down SW (down) : (Up) : Set SW : Test operation SW : Surge absorber : Low pressure sensor : Varistor : Connector : Connector : Terminal strip : Electronic expansion valve : Reversing solenoid valve : Ferrite core MF (lower side) (Discharge) (Outdoor) (Condenser) (Suction) (Liquid) M2F (upper side) Assignment of terminals of the comp. 3D BPMK928B42 YE-Y3E: Electronic expansion valve To indoor units Room B Transmission circuit Room A Transmission circuit Bypass From outdoor unit Transmission circuit Outdoor unit PCB FU HP-H6P RT-R6T : Printed circuit board : Fuse : Pilot lamp : Thermistor S-S3, S5 T XM-X4M : Connector : Transformer : Terminal strip 3D024655B Split - Sky Air Outdoor Units 23

26 Super Multi Plus R-407C RMX40JZ 8 Wiring diagrams 8 BPMK928B43 YE-Y3E: Electronic expansion valve To indoor units Room C Room B Transmission circuit Room A Transmission circuit Bypass From outdoor unit Transmission circuit Outdoor unit Transmission circuit PCB FU HP-H6P RT-R6T : Printed circuit board : Fuse : Pilot lamp : Thermistor S-S3, S5 T XM-X4M : Connector : Transformer : Terminal strip 3D024654B 24 Split - Sky Air Outdoor Units

27 Super Multi Plus R-407C RMX40JZ 9 Sound level 9- Sound level data Sound pressure level 9 Model Cooling 230V (50Hz) Heating Measuring location 9- RMX40JVMB Sound pressure spectrum RMX40JVMB (Cooling) RMX40JVMB (Heating) Octave band sound pressure level Octave band sound pressure level approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 3D02759A Octave band center frequency (Hz) 3D02759A Octave band center frequency (Hz) Note:. Operation sound is measured in an anechoic chamber. 2. Data is valid at free field condition Split - Sky Air Outdoor Units 25

28 Super Multi Plus R-407C RMX40JZ 0 Accessories Standard accessories To BP unit j + *English version j5 Wire clamp pc. pc. j2 For main gas piping Pipe joint pc. j6 Insulator j7 Hanger metal pc. j3 For branch lliquid piping j4 For branch gas piping pc. BPMK928B43 (For 3 rooms 3pcs.) j8 Screws 4 pcs. BPMK928B42 (For 2 rooms 2pcs.) 2pcs. Items to be prepared in the field + Connecting wires (H05VV, 4 wires,.6mm or 2.0mm) + Installation parts (hanging bolts: 4xM0orM8; nuts: 2; flat washers: 8) + Screws for wall-mounting: 6xM5 + Heat insulating cylinder (joint) [Thermal conductivity: W/mK ( kcal/mh C) or more / thickness 3mm (/2 inch) or more / Heat resistance:00 C or higher (Only heat pump system)] + Aluminium tape 26 Split - Sky Air Outdoor Units

29 Super Multi Plus R-407C RMX40JZ 0 Accessories 0-2 Optional accessories RMX40JZ Option name Central drain plug Kit name KKPJ5F Fixture for preventing overturning KPTJ60F60 Wire fixture for preventing overturning K-KBPA Auxiliary piping For front/side For rear KHFJ5F80F KHFJ5F80B Refnet joint Refnet joint Option name Kit name KHRJ928A4T Insulator Installation manual Super multi plus KHRP928A4T Inlet Outlet Inlet Outlet Outlet Outlet BP Units Accessories Installation manual pc. For main gas piping L Shape reducer pc. Gas 3 (φ5.9 / φ2.7 / φ9.5) For branch Liquid (φ9.5) Split - Sky Air Outdoor Units 27

30 Super Multi Plus R-407C RMX40JZ Centre of gravity RMX40JZ Foundation bolt 4D027597A 28 Split - Sky Air Outdoor Units

31 Super Multi Plus R-407C RMX40JZ Centre of gravity BPMK928B42 Electric box Electric box Setting for shipment When the electric box is attached to the other side The center of gravity shifts with the location of the electric box 3D024948A BPMK928B43 Electric box Electric box Setting for shipment When the electric box is attached to the other side The center of gravity shifts with the location of the electric box 3D024865A Split - Sky Air Outdoor Units 29

32 Super Multi Plus R-407C RMX40JZ 2 Installation 2 RMX40JZ The maximum allowable level and piping length Check the manual for installation that comes with outdoor units Outdoor unit Installation of the outdoor unit in an upper position BP unit model For 3 rooms: BPMK928B43 For 2 rooms: BPMK928B42 Main piping Do not connect more than 7 indoor units together. Choose the BP unit type (2 rooms or 3 rooms) according to the installation pattern. Branch piping Place the BP and indoor units within a level distance of 5m from each other. + Total main piping length : 55m (ja + jb + jc ) + Total branch piping length : 60m (L+L2+L3+L4+L5+L6+L7) + Each branch piping length : 5m (L,L2,L3,L4,L5,L6,L7) + Total system piping length : 5m (55+60) Installation of the outdoor unit in a lower position. Place the BP and indoor units within a level distance of 5m from each other. 30 Split - Sky Air Outdoor Units

33 Super Multi Plus R-407C RMX40JZ 2 Installation Main body installation (cautions for installation) 2. Check the strength and level of the foundation so that the air conditioner works without vibration or noise. 2. Fix the unit rigidly to the foundation with the foundation bolts as shown in the drawing at right. + Prepare 4 sets of M2 foundation bolts, nuts and washers available in the market + The projection of the foundation bolts should be 20 mm. Installation method of fitting for prevention of overturning + If overturning prevention is required, use the optional overturning prevention kit. Drain pipe disposal + If drain pipe disposal from the outdoor unit causes trouble, provide the drain piping by using of the drain socket (optional). Drain hole Installation service space The horizontal coupling and stacking are not allowed. (A) Where there is an obstacle on the suction side + No obstacle above Obstacle on the suction side only + Obstacle on both sides 00 or more + Obstacle above, Obstacle on the suction side, 00 or more 00 or more 00 or more 500 or less + Obstacle on the suction side and both sides 000 mm or more 500 or less 000 mm or more 00 or more (B) Where there is an obstacle on the discharge side + No obstacle above 50 or more 50 or more 50 or more 500 mm or more 500 or less 000 mm or more + Obstacle above, 500 mm or more Split - Sky Air Outdoor Units 3

34 Super Multi Plus R-407C RMX40JZ 2 Installation 2 (C) Where there are obstacles on both suction and discharge sides Pattern Where the obstacles on the discharge side is higher than the unit + No obstacle above 00 or more 500 mm or more + Obstacle above, No obstacle above 500 or less L A 000 mm or more L H H < L 0<L /2 H 750 /2H<L 000 Set the stand as : L <= H Close the bottom of the installation frame to prevent the discharged air from being bypassed. 200 or more (300) Pattern 2 Where the obstacles on the discharge side is higher than the unit + No obstacle above 00 or more + Obstacle above, No obstacle above 500 mm or more 500 or less 000 mm or more L A L H H < L 0<L /2 H 00 /2H<L 200 Set the stand as : L <= H Close the bottom of the installation frame to prevent the discharged air from being bypassed. (D) Multiple rows of series installation (on the rooftop, etc.) 500 mm or more 00 or more 000 mm or more 500 mm or more 200 or more (300) 32 Split - Sky Air Outdoor Units

35 Super Multi Plus R-407C RMX40JZ 2 Installation To BP unit + This unit may be installed suspended from the ceiling or mounted on the wall. + This unit may only be installed vertically, as shown in the diagram below. (Side D is facing up.) However, it may be freely installed in any direction forward or back, and to the sides. + Be sure to leave a 600mm square opening for service and inspection as shown in the diagram below, for both ceiling-suspended installation and wall-mounted installation. + This unit does not require drain treatment as it uses internal foam treatment as low-pressure piping insulation. + This unit may be installed with sides F or R facing forward (servicing direction). + The piping for the indoor unit may be freely led around in directions A, B or C. + The inclination of side D must be within ±5 degrees forward or back or to the sides. 2 Three-sided view (product dimensions and attachment bolt pitch) O.D.J5.9Cut I.D.J6.4Cut Wall mounted I.D.J9.5Cut I.D.J9.Cut Suspension bolt pitch Suspension bolt pitch 2x3-Brazing Branch piping Room A Collective indication label Terminal Main piping Wiring clamps Room B Room B Indication label (for indoor unit) Wiring clamp Earth terminal (M4) Indication label (for outdoor unit) 2-Brazing Installation restrictions Standard accessories (Installation and service space) j4 Precaution j2 For main piping (Gas) Service space (Precaution) Cut line for A Dimple I.D. J9. Cut line for I.D. J 5.9 Cut line for I.D. J 2.7 I.D. J9.5 j3 For branch piping (Liquid) Cut line Inspection opening Be sure to leave a 600mm square opening for service and maintenance. I.D. J9.5 Precaution: Cut the piping on the standard accessories to match the indoor unit s piping diameter. Split - Sky Air Outdoor Units 33

technical data air conditioning systems MXS-B Multi Application Split Sky Air

technical data air conditioning systems MXS-B Multi Application Split Sky Air technical data MXS-B Multi Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment

More information

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air technical data RXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human

More information

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air technical data RKS-C RKS-B Pair Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help

More information

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air technical data MA-GZ7 Multi Model Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect human health

More information

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air technical data FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette Multi (950mm Split Heat x 950mm) Pump (edited) air conditioning systems Split Sky Air Outdoor Units R40A MXS-DAVMB_E2VB_E7VB Features V i

More information

Outdoor Units R-410A ARX-GV1B

Outdoor Units R-410A ARX-GV1B Outdoor Units R-40A ARX-GVB t A i n y U k BS r o AV t o0g i d- lt4x pur- SRAO 2 Specifications Outdoor Units R-40A ARX-GVB 2- NOMINAL CAPACITY AND NOMINAL INPUT ARX20GVB ARX25GVB ARX5GVB For combination

More information

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

Split-Sky Air FDYP-B7 Concealed Ceiling Unit TECHNICAL DATA Split-Sky Air FDYP-B7 Concealed Ceiling Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the

More information

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series Inverter cooling only / heat pump series RSX(Y)P5,8,10K7W1 RSX(Y)P-K7W1 1 Inverter cooling only / heat pump series 1 1 Specifications

More information

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air technical data RYP-L7/B7 Pair Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the

More information

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application TECHNICAL DATA Split-Sky Air RP-B7 Twin/Triple/Double Twin Application Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment

More information

Split-Sky Air FAYP-B Wall Mounted Unit

Split-Sky Air FAYP-B Wall Mounted Unit TECHNICAL DATA Split-Sky Air FAYP-B Wall Mounted Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential

More information

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air technical data RQ-B7 Pair/Twin/Triple/Double Twin Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect

More information

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8 Air Conditioners Technical Data Individual branch selector for VRV heat recovery (Individual BS box) EEDEN11-200 BSVQ100-250P8 Air Conditioners Technical Data Individual branch selector for VRV heat recovery

More information

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................

More information

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air EEDEN08-00 technical data FDQ-B8V3B9 air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led

More information

Air Conditioning. Technical Data EEDEN RXZ-N

Air Conditioning. Technical Data EEDEN RXZ-N Air Conditioning Technical Data EEDEN14-100 RXZ-N TABLE OF CONTENTS RXZ-N 1 Features............................................................. 2 2 Specifications.......................................................

More information

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems Indoor Units

More information

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units t i t l r - I Features s e Cs m B ne d E Ue V s 7 ya P os e oc Q dvn S nr ox VF C Reduction of power consumption of 20% (compared to FXSQ-M8 series) through use of new DC fan Improved comfort thanks to

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV Air Conditioning Technical Data Wall mounted unit EEDEN15-100 FTX-GV TABLE OF CONTENTS FTX-GV 1 Features............................................................. 2 2 Specifications.......................................................

More information

technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

technical data Systems FXMQ-MVE Conceiled ceiling unit (large) technical data Systems FXMQ-MVE Conceiled ceiling unit (large) FXMQ-MVE 11 Concealed ceiling unit (large) 11 1 Features...2 2 Specifications Technical specifications...3 Electrical specifications...4 Safety

More information

Air Conditioning. Technical Data EEDEN RXZ-N

Air Conditioning. Technical Data EEDEN RXZ-N Air Conditioning Technical Data EEDEN15-100 RXZ-N Outdoor Unit RXZ-N TABLE OF CONTENTS RXZ-N 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................

More information

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps RZQG71L8Y1B RZQG100L8Y1B RZQG125L8Y1B RZQG140L7Y1B Sound pressure level Heating Nom. dba 50 52 53 53 Cooling Nom. dba 48 50 51 52 Night quiet mode Level 1 dba 43 45 45 45 Standard Accessories Item Tie-wraps

More information

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units i r -t i l t - Outdoor Units R-40A RZQ7-40C7VB Features V 7n y CU k 0 S 4 oa o 0 d 7 4Q puz RO S Outdoor units for pair, twin, triple, double twin application The Sky Air Inverter is developed for use

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r u n i t E E D E N 2-0 0 RXG-K Outdoor Unit Pair application RXG-K TABLE OF CONTENTS RXG-K Features.............................................................

More information

technical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air

technical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air technical data FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help

More information

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Split Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Indoor Unit FTXC-A TABLE OF CONTENTS FTXC-A 1 Features.............................................................

More information

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump)

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) PRK 00-04 PREVIEW System OZONE FRIENDLY R-407C Series Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) 3DUW#4 2XWGRRU#8QLWV 111111111111111111111111111111111111111111111111111111111111111111111

More information

Air Conditioning Technical Data RZQG-L(8)Y1

Air Conditioning Technical Data RZQG-L(8)Y1 Air Conditioning Technical Data RZQG-L(8)Y TABLE OF CONTENTS RZQG-L(8)Y Features............................................................. 2 2 Specifications.......................................................

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

Air Conditioning Technical Data RZQSG-L3/9V1

Air Conditioning Technical Data RZQSG-L3/9V1 Air Conditioning Technical Data RZQSG-L/9V1 Outdoor Unit RZQSG-L/9V1 TABLE OF CONTENTS RZQSG-L/9V1 1 Features............................................................. 2 2 Specifications.......................................................

More information

Technical Service Manual

Technical Service Manual Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........

More information

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................

More information

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1

More information

Air Conditioning. Technical Data EEDEN RXJ-L

Air Conditioning. Technical Data EEDEN RXJ-L ir Conditioning Technical Data EEDEN5-0 RXJ-L Outdoor Unit RXJ-L TLE OF CONTENTS RXJ-L Features............................................................. Specifications.......................................................

More information

Compact Four-way Cassette Type

Compact Four-way Cassette Type 1. Features... 34 2. Specifications... 35 3. Dimensions... 37 4. Service Spaces... 38 5. Piping Diagrams (EXV beside)... 39 6. Wiring Diagrams... 40 7. Capacity Tables... 41 8. Electrical Characteristics...

More information

Air Conditioning. Technical Data. VRV IV water cooled series EEDEN RWEYQ-T8

Air Conditioning. Technical Data. VRV IV water cooled series EEDEN RWEYQ-T8 Air Conditioning Technical Data VRV IV water cooled series EEDEN15-201 Outdoor Unit TABLE OF CONTENTS 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB

Air Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB Air Conditioning Technical Data Heat reclaim ventilation EEDEN14-205 VAM-FA/FB Heat reclaim ventilation VAM-FA/FB VAM-FA/FB 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioners. Technical Data. VRV III heat recovery, with connection to heating only hydrobox REYAQ-P

Air Conditioners. Technical Data. VRV III heat recovery, with connection to heating only hydrobox REYAQ-P Air Conditioners Technical Data VRV III heat recovery, with connection to heating only hydrobox E E D E N 1 1-2 0 0 REYAQ-P Air Conditioners Technical Data VRV III heat recovery, with connection to heating

More information

Four-way Cassette Type

Four-way Cassette Type Four-way Cassette Type Four-way Cassette Type 1. Features... 9 2. Specifications... 12 3. Dimensions... 17 4. Service Space... 18 5. Wiring Diagrams... 19 6. Capacity Tables... 21 7. Electric Characteristics...

More information

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features 19 Series High-Efficiency Wall-Mounted Ductless systems Performance: Up to 19 SEER 12.5 EER 9.0 HSPF Product Features Inverter Compressor 208/230/1 Power Supply Cooling Range: -4-115 F (with optional wind

More information

Oil Cooler AKZ328-D142 PL

Oil Cooler AKZ328-D142 PL Oil Cooler PL-1009-15 1 2 Parts Parts Name Drwg. Parts Model & Specifi cation A1 A 1250093 SWING COMPRESSOR 1YC23HXD 1 M2C A2 0401393 RUBBER BUSH/ LEAD WIRE W443132-2 1 A4 390204 NUT WITH WASHER R4911377-1

More information

PRODUCT CODE MODEL NAME. No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty Qty REMARKS

PRODUCT CODE MODEL NAME. No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty Qty REMARKS ERSATZTEILE RAS-4HNC1E, 3~ 400V 50Hz RAS-5HNC1E, 3~ 400V 50Hz RAS-6HNC1E, 3~ 400V 50Hz 1 Rear Cover Assy XEK24870 A E03946 1 1 1 1 1 1 Assembly 1-1 Pipe Cover B 17C86251 A P27003 1 1 1 1 1 1 1-2 Handle

More information

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CV3

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CV3 Heating Technical Data Daikin Altherma low temperature split EEDEN2-725 ERLQ-CV Daikin Altherma low temperature split ERLQ-CV TABLE OF CONTENTS ERLQ-CV Features.............................................................

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book DVM S Eco for America (R410A, 60Hz, HR) Model : AM***NXMDCR/AA History Version Modification Date Remark Ver.1.0 Released DVM S Eco HR for North America TDB 18.02.28 Ver.1. Re 18.0

More information

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors

More information

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams... MCAC-VTSM-2013-08 1. Features... 264 2. Specifications... 265 3. Dimensions... 268 4. Service Spaces... 272 5. Piping Diagrams... 273 6. Wiring Diagrams... 274 7. Capacity Tables... 276 8. Electrical Characteristics...

More information

WCA4**4. Product Specifications

WCA4**4. Product Specifications WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-90EB RO-90EPB C O N T E N T S SPECIFICATIONS... OUTLINE AND DIMENSIONS... CIRCUIT DIAGRAM...5 REFRIGERANT SYSTEM DIAGRAM...6

More information

SkyAir, Packaged Outdoor Units (RoHS application) RQ71KBV4A, RZQ71KBV1, RZQ71KBV4A, RZQ100KBV1 RZQ150HY4A RZQ150KV4A PL-908-1

SkyAir, Packaged Outdoor Units (RoHS application) RQ71KBV4A, RZQ71KBV1, RZQ71KBV4A, RZQ100KBV1 RZQ150HY4A RZQ150KV4A PL-908-1 SkyAir, Packaged Outdoor Units (RoHS application) RQKBV4A, KBV1, KBV4A, 100KBV1 150HY4A 150KV4A PL-908-1 RQKBV4A / KBV1 / KBV4A / 100KBV1 (RoHS application) RQKBV4A / KBV1 / KBV4A / 100KBV1 (RoHS application)

More information

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,

More information

SERVICE MANUAL OUTDOOR UNIT. No. OB386

SERVICE MANUAL OUTDOOR UNIT. No. OB386 SPLIT-TYPE AIR CONDITIONERS Revision D: MU-A20VB- E and MU-A5VB- E have been added. Please void OB86 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A No. OB86 REVISED EDITION-D Models MU-A20VB-

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASH9LSACW ASH12LSACW Outdoor unit AOH9LSAC AOH12LSAC CONTENTS SPECIFICATIONS...................... 1 DIMENSIONS..........................

More information

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E SPLIT TYPE AIR CONDITIONER CASSETTE type Models Indoor unit Outdoor unit C24YE MC24Y3E MR24Y3E1 SPECIFICATIONS TYPE COOL & HEAT INDOOR UNIT MC24Y3E OUTDOOR UNIT MR24Y3E1 COOLING CAPACITY 23,500-22,500

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXS-K

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXS-K Air Conditioning Technical Data Wall mounted unit EEDEN3-00 FTXS-K Indoor Unit Wall mounted unit FTXS-K TABLE OF CONTENTS FTXS-K Features............................................................. 2

More information

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series VRF Indoor Unit 50Hz Type: Wall Mounted M Series Wall Mounted S Series Contents 01 Wall Mounted M Series 20 Wall Mounted S Series MCAC-VTSM-2016-05 Wall Mounted M Series Wall Mounted M Series 1. Features...

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz] R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1

More information

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E R407C TECHNICAL MANUAL Split Systems Air Conditioner Ducted Blower D & E Series FDMP-D, FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E series Cooling only & Heatpump [50Hz] Table of Contents Table of Contents

More information

TSA6. Product Specifications. SmartComfort TXC 5600

TSA6. Product Specifications. SmartComfort TXC 5600 ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230

More information

SERVICE MANUAL OUTDOOR UNIT. No. OB387

SERVICE MANUAL OUTDOOR UNIT. No. OB387 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision C: MUH-A25VB - E has been added. Please void OB87 REVISED EDITION-B. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A. OB87 REVISED EDITION-C Wireless type

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

Fan Coil Units. Technical Data

Fan Coil Units. Technical Data Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Table of Contents Table of Contents 3 Round Flow Cassette...

More information

High Wall Type ( 2 Series )

High Wall Type ( 2 Series ) Jan.05' Engineering Data High Wall Type ( 2 Series ) Indoor Unit MMK-AP0072H MMK-AP0092H MMK-AP0122H 1. Equipments 2. Technical Specifications 3. Dimensional Drawing 4. Wiring Diagram 5. Refrigerant Cycle

More information

PRODUCT CODE MODEL NAME RASC-10HNPE. No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty REMARKS

PRODUCT CODE MODEL NAME RASC-10HNPE. No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty REMARKS 7E343107 RASC-4HNPE RASC-5HNPE RASC-6HNPE 7E343108 7E343109 No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty REMARKS 1 Foot Assy XEK38712 A E04359 1 1 1 Assembly 1 Foot Assy XEK39008 A E04384 1 1 Assembly

More information

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4

More information

N4A4 C. Product Specifications

N4A4 C. Product Specifications COASTAL 14 SEER AIR CONDITIONER 14 SEER/11.5 12.5 EER R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter drier

More information

A2P H2P H4P H6P H1P H3P H5P H7P. Outdoor X205A OFF Y1E E1H R6T X5A F8U F7U K14R K2R X28A X6A SEE NOTE 7 HAP X77A X31A X13A X21A P< S1PL P> S1PH

A2P H2P H4P H6P H1P H3P H5P H7P. Outdoor X205A OFF Y1E E1H R6T X5A F8U F7U K14R K2R X28A X6A SEE NOTE 7 HAP X77A X31A X13A X21A P< S1PL P> S1PH RZQSG00L9V N L N 50Hz 0-40V Z5 GRN D089497B WHT HR BRNHR3 PPLHR4 HR + E K0R V3D L N LA FU FU ZF ZF KM Z GRN/YLW Z 5 NA VT VT VD + R VR FU V Z3F Z4 X0A WHT X50A 4 MF MS M3 MS ~ Position of compressor terminal

More information

SERVICE MANUAL MU-GA20VB- MU-GA20VB- MU-GA25VB- MU-GA25VB- MU-GA35VB- E1 OUTDOOR UNIT. No. OB386. Wireless type Models HFC

SERVICE MANUAL MU-GA20VB- MU-GA20VB- MU-GA25VB- MU-GA25VB- MU-GA35VB- E1 OUTDOOR UNIT. No. OB386. Wireless type Models HFC SPLIT-TYPE, AIR CONDITIONERS Revision B: MU-A20VB- E2 and MU-A25VB - have been added. Please void OB86 REVISED EDITION-A. E2 OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A No. OB86 REVISED EDITION-B Wireless

More information

CSA6. Product Specifications. SoftSound SXC 2600

CSA6. Product Specifications. SoftSound SXC 2600 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models

More information

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with

More information

AIR-CONDITIONER SERVICE MANUAL. RBM-Y1034F-PE (3-way) 3-PIPE SUPER MULTI, HEAT PUMP WITH SIMULTANEOUS HEATING AND COOLING. RBM-Y1044F-PE (4-way)

AIR-CONDITIONER SERVICE MANUAL. RBM-Y1034F-PE (3-way) 3-PIPE SUPER MULTI, HEAT PUMP WITH SIMULTANEOUS HEATING AND COOLING. RBM-Y1044F-PE (4-way) FILE NO. A90-9922 SERVICE MANUAL AIR-CONDITIONER Outdoor Unit Multi Controller 2-PIPE SUPER MULTI, HEAT PUMP MAR-M104HTM8-PE RBM-Y1034-PE (3-way) RBM-Y1044-PE (4-way) 3-PIPE SUPER MULTI, HEAT PUMP WITH

More information

Low Static Pressure Duct(V shape evaporator)

Low Static Pressure Duct(V shape evaporator) Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...

More information

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz R2A3 Product Specifications For Use With R 22 Refrigerant AIR CONDITIONER COMPONENT 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

FTXS50EV1B, FTXS60EV1B (RoHS application) FTXS50EV1B, FTXS60EV1B Wiring Diagram

FTXS50EV1B, FTXS60EV1B (RoHS application) FTXS50EV1B, FTXS60EV1B Wiring Diagram 42 FTXS50EV1B, FTXS60EV1B (RoHS application) FTXS50EV1B, FTXS60EV1B Diagram FTXS50EV1B, FTXS60EV1B (RoHS application) 43 44 FTXS50EV1B, FTXS60EV1B (RoHS application) Parts Parts Name Drwg. Parts Model

More information

N2AE - 50 Hz PRODUCT SPECIFICATIONS

N2AE - 50 Hz PRODUCT SPECIFICATIONS ISO 9001:2000 REGISTERED N2AE - 50 Hz PRODUCT SPECIFICATIONS 50 Hz AIR CONDITIONING CONDENSING UNIT 230 Volt, 1-phase, 50 Hz in 1½, 2, 2½, 3, 4 tons 400 Volt, 3-phase, 50 Hz in 3, 3½, 4, 5 tons REFRIGERATION

More information

Air Conditioners. Technical Data UATYQ-CY1

Air Conditioners. Technical Data UATYQ-CY1 Air Conditioners Technical Data R o o f t o p s E E D E N 2-2 0 UATYQ-CY Air Conditioners Technical Data R o o f t o p s E E D E N 2-2 0 UATYQ-CY Single Unit Rooftop UATYQ-CY TABLE OF CONTENTS UATYQ-CY

More information

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz 3 PHASE HEAT PUMP COMPONENT 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain proper charge of mineral oil Suction line accumulator

More information

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230

More information

Service manual MIV V4+ Indoor units

Service manual MIV V4+ Indoor units Service manual MIV V4+ Indoor units Floor Standing MVF22A-VA1 MVF28A-VA1 MVF36A-VA1 MV5A-VA1 MVF56A-VA1 MVF71A-VA1 MVF80A-VA1 MVB22A-VA1 MVB28A-VA1 MVB36A-VA1 MVB45A-VA1 MVB56A-VA1 MVB71A-VA1 MVB80A-VA1

More information

PL Split Indoor Units FTKD25GVM, FTKD35GVM FTKD25GVM4, FTKD35GVM4. Split Outdoor Units RKD50GVM RKD60GVM RKD50GVM4 RKD60GVM4

PL Split Indoor Units FTKD25GVM, FTKD35GVM FTKD25GVM4, FTKD35GVM4. Split Outdoor Units RKD50GVM RKD60GVM RKD50GVM4 RKD60GVM4 Split Indoor Units FTKD25GVM, FTKD35GVM FTKD25GVM4, FTKD35GVM4 Split Outdoor Units RKD50GVM RKD60GVM RKD50GVM4 RKD60GVM4 Ceiling Consealed Split - OYL Malaysian Products (for Midle East) FDM30JEVLK, FDYM30JEVLK,

More information

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Indoor Console Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Black Display Functional art, the touch screen display is elegant

More information

Preface. After sales service division

Preface. After sales service division EX-38 JULY 2001 Preface 1. This express parts list is made for offering spare parts information to customer as soon as possible. This spare parts list has list of spare parts information of this month

More information

PL-804. Remote Controller (RoHS application) BRC7F634F, BRC7F635F

PL-804. Remote Controller (RoHS application) BRC7F634F, BRC7F635F Split Indoor Units (RoHS application) FTK20GVLT, FTK25GVLT, FTK30GVLT FTX20GVLT, FTX25GVLT, FTX30GVLT FTKS42GVLT FTXS42GVLT Split Indoor Units (RoHS application) (Revised from PL-802) FTY25GXV1, FTY35GXV1

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

HYDROCIAT LW R134a. Water cooled chillers USE RANGE Screw compressors CIAT direct expansion shell and tubes evaporator equipment (High Power System) Cooling or heating Heat recovery ENVIRONMENTALLY HFC R134a PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping

More information

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES: 15SEERSplitHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

FFQN-C, FCRN-E, FFRN-C

FFQN-C, FCRN-E, FFRN-C R410A TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FCQN-E, FFQN-C, FCRN-E, FFRN-C Cooling only & Heatpump [50Hz] DAIKIN_FFRN.indb i 12/27/2012 9:28:06 AM DAIKIN_FFRN.indb ii

More information

UWA180AY3 UWA180AY3 Wiring Diagram

UWA180AY3 UWA180AY3 Wiring Diagram Diagram 330 Diagram 331 332 333 334 335 336 337 338 A1 A 6001875 SCREW COMPRESSOR ZH5LMG3YE 3 A3 6001876 TERMINAL COVER ASSY. 3PG20260-1 3 A4 6001877 TERMINAL COVER 3PG20261-1 3 A5 6001589 THREE-WAY VALVE

More information

REYQ14PY1B / REYQ16PY1B (RoHS application) REYQ14PY1B / REYQ16PY1B Wiring Diagram

REYQ14PY1B / REYQ16PY1B (RoHS application) REYQ14PY1B / REYQ16PY1B Wiring Diagram 14PY1B / 16PY1B (RoHS application) 14PY1B / 16PY1B Diagram 204 14PY1B / 16PY1B (RoHS application) 205 14PY1B / 16PY1B (RoHS application) 206 14PY1B / 16PY1B (RoHS application) 207 208 14PY1B / 16PY1B (RoHS

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2013.12 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information