WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models
|
|
- Eleanor Wiggins
- 5 years ago
- Views:
Transcription
1 SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASH9LSACW ASH12LSACW Outdoor unit AOH9LSAC AOH12LSAC CONTENTS SPECIFICATIONS DIMENSIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM DIAGRAM ERROR CONTENTS PCB CIRCUIT DIAGRAM DISASSEMBLY ILLUSTRATION PARTS LIST STANDARD ACCESSORIES
2 SPECIFICATIONS TYPE (COOL&HEAT INVERTER) (COOL&HEAT INVERTER) INDOOR UNIT ASH9LSACW ASH12LSACW OUTDOOR UNIT AOH9LSAC AOH12LSAC COOLING CAPACITY( ) : Range (kw) 2.6 (0.5~3.6) 3.5 (0.9~4.2) HEATING CAPACITY( ) : Range (kw) 3.6 (0.5~6.0) 4.8 (0.9~6.6) ELECTRICAL DATA POWER SOURCE (V) 230 FREQUENCY (Hz) 50 RUNNING CURRENT (A) COOLING HEATING INPUT WATTS (kw) COOLING 0.68 (0.25~1.38) 1.03 (0.25~1.61) HEATING 0.91 (0.25~1.96) 1.33 (0.25~2.30) EER (kw/kw) COOLING HEATING MOISTURE REMOVAL ( /hr) AIR CIRCULATION-Hi (m 3 /hr) C 630 H665 C 630 H700 COMPRESSOR TYPE DISCRIMINATION REFRIGERANT R410A (g) Hermetic type,4 pole, 3 phase, DC brushles motor Note : Always use a vacuum pump to purge the air. Refrigerant for purging the air is not charged in the outdoor unit at the factory FAN MOTOR POWER SOURCE (V) 230 HI-SPEED C 1,350 H 1,420 INDOOR UNIT MED-SPEED C 1,150 H 1,200 LO-SPEED C 950 H 1,000 (r.p.m.) QUIET C 740 H 900 OUTDOOR UNIT (r.p.m.) 830 C 1,400 H 1,470 C 1,200 H 1,290 C 1,000 H 1,110 C 820 H 980 DIMENSIONS INDOOR UNIT H x W x D (mm) 280 x 790 x 230 OUTDOOR UNIT H x W x D (mm) 535 x 780 x 250 WEIGHTS INDOOR UNIT GROSS / NET (kg) 12 / 9 OUTDOOR UNIT GROSS / NET (kg) 35 / / 34 NOISE LEVEL HI-SPEED C 42 H 42 C 43 H 43 MED-SPEED C 37 H 36 C 39 H38 INDOOR UNIT LO-SPEED C 31 H 30 C 32 H 33 (db) QUIET C 23 H 26 C 26 H 29 OUTDOOR UNIT (db) C 47 H 49 Note : Noise was measured in accordance with JIS standards, Japan. MAX PIPE LENGTH ADDITIONAL REFRIGERANT 15 m None 1
3 DIMENSIONS Models : ASH9LSACW / AOH9LSAC ASH12LSACW / AOH12LSAC
4 CIRCUIT DIAGRAM Models : ASH9LSACW / AOH9LSAC ASH12LSACW / AOH12LSAC INDOOR UNIT OUTDOOR UNIT Controller PCB Thermistor (discharge pipe) Thermistor (pipe) Thermistor (outdoor temp.) 3
5 REFRIGERANT SYSTEM DIAGRAM Models : ASH9LSACW / AOH9LSACW ASH12LSACW / AOH12LSACW Muffler (2 pass) Compressor 3way-valve Indoor heat exchanger 2way-valve 4way-valve Accumulator Strainer Dryer (2 pass) Outdoor heat exchanger Capillary tube Pulse motor valve 4
6 ERROR CONTENTS Self-diagnosis function table (Flashing LED Display) Applicable model : ASH9LSACW, ASH12LSACW * Detailed Trouble Display (secondary level) can be indicated by pressing Test Operation button. Trouble Display (primary) Detailed Trouble Display (by Test Button) Error Operation Timer Error Operation Timer Serial signal Normal 1 sec Serial reverse signal error 0.1sec 0.5sec error blinking at operation start up blinking 2 times Detailed Error Item Normal Serial Reverse Signal can not be received more than 10 secs >>Releases when it becomes normal Signal reverse signal error during operation 0.1sec blinking 0.5sec 3 times Normal Serial Reverse Signal can not be received more than 7 secs (after receiving effective reverse transfer signal) >>Releases when it becomes normal Serial forward signal error at operation start up 0.1sec blinking 0.5 sec 4 times Normal Serial Forward Signal can not be received more than 10 secs Serial forward signal error during operation 0.1sec blinking 0.5sec 5 times >>Releases when it becomes normal Normal Serial Forward Signal can not be received more than 10 secs ( after receiving effective forward transfer signal) >>Releases when it becomes normal Indoor unit 0.5sec 0.1sec Indoor temperature 0.1sec 0.5sec Thermistor detection value is open when thermistor 2 times blinking thermistor open blinking 2 times AC plug is inserted error >>Releases when value becomes normal Pipe thermistor 0.1sec 0.5sec Thermistor detection value is open or short open or short blinking 3 times when AC plug is inserted >>Releases when value becomes normal Outdoor unit 0.5sec 0.1sec Discharge thermistor 0.1sec 0.5sec Thermistor detection value is open or short thermistor 3 times blinking open or short blinking 2 times error >>Outdoor unit stops Releases when it becomes normal Heat exchanger 0.1sec 0.5sec Thermistor detection value is open thermistor open blinking 3 times >>Outdoor unit stops Releases when it becomes normal Outdoor temperature 0.1sec 0.5sec Thermistor detection value is open or short thermistor open or short blinking 4 times >>Outdoor unit stops Releases when it becomes normal Indoor unit 0.5sec 0.1sec Forced automatic SW 0.1sec 0.5sec Forced Auto SW is ON for more than control error 4 times blinking welded blinking 2 times 10 secs continuously >>Error is indicated while it is ON Normal Operation other than error indication Main relay welded 0.1sec 0.5sec Serial Reverse Signal is received 1 min. blinking 3 times after Main relay becomes OFF >>Error is indicated while serial reverse signal is input on normal operation Normal operation except error indication Power interruption error 0.1sec 0.5sec 50/60Hz is not detected after 2 secs of blinking 4 times power ON. Indoor Indoor Indoor Indoor Indoor Outdoor Outdoor Outdoor >>Error is indicated and unit is stopped 5
7 Trouble Display (primary) Detailed Trouble Display (by Test Button) Error Operation Timer Error Operation Timer Outdoor unit 0.5sec 0.1sec Current trip 0.1sec 0.5sec Current trip error is 2nd time within control error 5 times blinking blinking 2 times start up Indoor Indoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor >>Permanent stop CT abnormal 0.1sec 0.5sec Current detection value is 0A for more blinking 3 times than 1 sec when compressor is operated at more than 90rps >>Outdoor unit is stopped until power supply to Outdoor unit is stopped Compressor rotation error 0.1sec 0.5sec Compressor location detection error (incl. blinking 5 times failed start up) for 3 times >>Permanent stop Indoor fan 0.5sec 0.1sec Abnormal lock 0.1sec 0.5sec Detected rotation is 0 r.p.m. at start up or motor error 6 times blinking blinking 2 times at 56 secs after Fan mode is selected >>Permanent stop Abnormal rotation 0.1sec 0.5sec Detected rotation is 1/3 of target r.p.m. at blinking 3 times start up or at 56 secs after Fan mode is selected >>Permanent stop Refrigerant 0.5sec 0.1sec Discharge temperature 0.1sec 0.5sec Discharge Temperature protection cycle error 7 times blinking abnormal blinking 2 times (Discharge temperature is 110degC) operated 2 times >>Permanent stop Cooling high pressure abnormal rise Detailed Error Item 0.1sec 0.5sec High pressure rise protection (Outdoor blinking 3 times heat exchanger temperature is 65degC) operated >>Comp. OFF (releases after 3min.ST) Error is indicated while 3 min.st Optional 0.5sec 0.1sec Active filter voltage 0.1sec 0.5sec Active Filter voltage error operated 3 times function 8 times blinking abnormal (3rd time) blinking 2 times error >>Permanent stop Active filter voltage 0.1sec 0.5sec Active Filter Module error or open abnormal (1st time) blinking detection protection operated 3 times >>Automatic release after 3 min. ST
8 INDOOR PCB CIRCUIT DIAGRAM TERMINAL BOARD BLUE POWER SOURCE 220 / 240V 50Hz GREEN / YELLOW RED WHITE BROWN BLACK CONTROLLER PCB ASEMBLY (MAIN PCB) ASH9LSACW : EZ-00219HSE-C ASH12LSACW : EZ-0021CHSE-C THERMAL FUSE GRAY GRAY I C 1 upd780024sgb-x09 BLACK BLACK ROOM TEMPERATURE THERMISTOR GRAY PIPE TEMPERATURE THERMISTOR GRAY GREEN GREEN INDICATOR PCB EZ-00219HSE-D (F) RED WHITE WHITE WHITE WHITE WHITE WHITE REMOTE CONTROL CUSTOM CODE RED ORANGE YELLOW PINK BLUE LOUVER AUTO RESTART RED FAN MOTOR BLACK WHITE YELLOW BLUE 7
9 OUTDOOR PCB CIRCUIT DIAGRAM POWER SOURCE V 50Hz CONTROLLER PCB ASSEMBLY ( MAIN PCB) AOH9LSAC : EZ-002LHUE-C AOH12LSAC : EZ-002GHUE-C SC-10-55JH N200500K MB AOY12LSAC AOY9LSAC 8
10 DISASSEMBLY ILLUSTRATION Models : ASH9LSACW ASH12LSACW 9
11 Models : ASH9LSACW ASH12LSACW 10
12 Models : AOH9LSACW AOH12LSACW 11
13 PARTS LIST INDOOR UNIT Ref. No. Description ASH9LSACW Part No. ASH12LSACW Ord. Q'ty 1 2 Air Filter-L Air Filter-R Guide (Filter)-L Guide (Filter)-R Grille (Top)-L Grille (Top)-R Front Panel Assy Emblem-A Emblem-B Bearing (Panel)-L Bearing (Panel)-R Grille (Intake)-L Grille (Intake)-R Shaft (Grille)-L Shaft (Grille)-R Gear-A Casing Assy Cover (Casing)-B Cross Flow Fan Assy Motor Cushion-B Clamper (Motor) Shaft Holder-C Assy Drain Hose Assy Drain Cap Assy Wire Clamper Box (Switch) Cover (Switch) Evaporator Total Assy Joint Pipe Assy-E Insulation(Pipe)-E Holder (Evaporator)-L Holder (Evaporator)-R Water Seal Air Seal Terminal Step Motor Fan Motor Assy Remote Control Unit Bracket Panel Flow Control Panel-U Flow Control Panel-Z Power Cord Controller PCB Assy Pipe Thermister Room Thermister Indicator PCB When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. 12
14 OUTDOOR UNIT Ref. No. Description AOH9LSAC Part No. AOH12LSAC Ord. Q'ty Blow Grill Grip Cabinet Front Panel, Painted Electric Cover Cabinet Rear Panel, Painted Pulse Motor Valve Base Assy, Painted Way Valve Assy Condenser Sub Assy Way Valve Assy Inverter PCB Assy Thermistor (Discharge) Solenoid Coil Coil (Expansion Valve) Propeller Fan Inverter Cover Inverter Base Fan Motor Assy Bracket (Motor) Compressor Assy Thermistor (Condenser) Fan Ring Separate Wall Way Valve Protective Net Panel Top, Painted Emblem Inverter capacitor Fan capacitor Outdoor Thermister Controller PCB (EZ-002LHUE-C) (EZ-002GHUE-C) --- ACTPM PCB TR PCB Assy (K04AK-0400HUE-TRO) --- Diobe Bridge PCB (EZ-002GHUE-DB) (EZ-002GHUE-DB) --- Noise Filter beside compressor Noise Filter beside diobe bridge PCB When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. 13
15 STANDARD ACCESSORIES Name and Shape Part No. ASH9LSACW ASH12LSACW Wall hook bracket Remote control unit Battery (penlight) Cloth tape Tapping screw ( 4 x 25 )
16 0304G2230
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................
More informationSPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE
SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE Indoor unit AGYF09LAC AGYFLAC AGYFLAC AGYFLAC Outdoor unit AOYV09LAC AOYVLAC AOYVLAC AOYVLAL CONTENTS SPECIFICATIONS..................... DIMENSIONS.........................
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER ASY9USBCW AOY9UGBC ASY12USBCW AOY12UGBC. Models Indoor unit Outdoor unit
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit Outdoor unit ASY9USBCW AOY9UGBC ASY12USBCW AOY12UGBC CONTENTS SPECIFICATIONS....................... 1 OUTLINE AND DIMENSIONS............
More informationASU18RLB ASU24RLB AOU18RLB AOU24RLB SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASU8RL ASURL Outdoor unit AOU8RL AOURL CONTENTS SPECIFICATIONS................... DIMENSIONS...................... REFRIGERANT SYSTEM DIAGRAM....
More informationDUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S
SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-90EB RO-90EPB C O N T E N T S SPECIFICATIONS... OUTLINE AND DIMENSIONS... CIRCUIT DIAGRAM...5 REFRIGERANT SYSTEM DIAGRAM...6
More informationSPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E
SPLIT TYPE AIR CONDITIONER CASSETTE type Models Indoor unit Outdoor unit C24YE MC24Y3E MR24Y3E1 SPECIFICATIONS TYPE COOL & HEAT INDOOR UNIT MC24Y3E OUTDOOR UNIT MR24Y3E1 COOLING CAPACITY 23,500-22,500
More informationCASSETTE type SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS
SPLIT TYPE AIR CONDITIONER CASSETTE type Models Indoor unit Outdoor unit AUU8RC AUU4RC AOU8RC AOU4RC CONTENTS SPECIFICATIONS........................................ OUTLINE AND DIMENSIONS..............................
More informationSPLIT TYPE AIR CONDITIONER (50Hz) DUCT type
SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit ARY7RLB AOY7RGA CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... 2 CIRCUIT DIAGRAM... 3 INDOOR P. C. BOARD CIRCUIT DIAGRAM...
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-25CA RCW-30CA RO-25A RO-30A C O N T E N T S SPECIFICATIONS........................................ 1 OUTLINE AND DIMENSIONS..............................
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit Outdoor unit RSW-17AC ROW-17AC C O N T E N T S SPECIFICATIONS........................................ 1 REFRIGERANT SYSTEM DIAGRAM........................
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS RO-25A RO-25RA RO-30A RO-30RA RC-25A RC-25RA RC-30A RC-30RA
SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RC-25A RC-25RA RC-30A RC-30RA RO-25A RO-25RA RO-30A RO-30RA CONTENTS SPECIFICATIONS........................................
More informationCEILING WALL type INVERTER
SPLIT TYPE ROOM AIR CONDITIONER CEILING WALL type INVERTER Models Indoor unit AWY14LSAZ AWH14LSAZ AWY17LSAZ AWH17LSAZ Outdoor unit AOY14LSAWC AOH14LSAWC AOY17LSAWC AOH17LSAWC CONTENTS SPECIFICATIONS....................
More informationWA L L M O U N T E D t y pe SPLIT TYPE ROOM AIR CONDITIONER Models
SPLIT TYPE ROOM AIR CONDITIONER WA L L M O U N T E D t y pe Models Indoor unit Outdoor unit ASGFBAJ ASGFBBJ ASGUBAJ ASGUBBJ ASGFBBJ ASGUBBJ ASG0FBBJ ASG0UBBJ ( made in Thailand ) AOGFNAK AOGFNBK AOGUNAKL
More informationR410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2
R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1
More informationPRODUCT CODE MODEL NAME. No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty Qty REMARKS
ERSATZTEILE RAS-4HNC1E, 3~ 400V 50Hz RAS-5HNC1E, 3~ 400V 50Hz RAS-6HNC1E, 3~ 400V 50Hz 1 Rear Cover Assy XEK24870 A E03946 1 1 1 1 1 1 Assembly 1-1 Pipe Cover B 17C86251 A P27003 1 1 1 1 1 1 1-2 Handle
More informationFault Codes. J control
J control Timer Temp Fault Codes 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 Enter unit inspection mode by pushing the UP and DOWN buttons simultaneously for two seconds. Ensure that the
More informationSPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU18RLF ASU24RLF AOU18RLXFW AOU24RLXFW R410A CONTENTS 1. DESCRIPTION OF EACH CONTROL OPERATION
More informationPART7. Trouble Shooting
PART7. Trouble Shooting 1. Indoor Unit Error Display Display E0 E1 E2 E3 E5 LED STATUS EEPROM parameter error Indoor unit and outdoor unit communication protection Zero-crossing signal error Indoor fan
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationPRODUCT CODE MODEL NAME RASC-10HNPE. No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty REMARKS
7E343107 RASC-4HNPE RASC-5HNPE RASC-6HNPE 7E343108 7E343109 No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty REMARKS 1 Foot Assy XEK38712 A E04359 1 1 1 Assembly 1 Foot Assy XEK39008 A E04384 1 1 Assembly
More informationPart 2 Functional Description
ESIE06-0 Part Functional Description What is in this part? This part contains information on the functions used to control the system. Understanding these functions is vital when diagnosing a malfunction
More informationSERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Compact Wall Mounted Wall Mounted / Floor Compact Cassette / Slim Duct INVERTER MULTI
SPLIT TYPE ROOM AIR CONDITIONER Compact Wall Mounted Wall Mounted / Floor Compact Cassette / Slim Duct INVERTER MULTI SERVICE INSTRUCTION Models Indoor unit Outdoor unit ASU7RLF ASU9RLF ASU2RLF ASU8RLF
More informationtechnical data air conditioning systems MXS-B Multi Application Split Sky Air
technical data MXS-B Multi Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment
More informationSPARE PARTS CATALOG OFFICE PRO 18. DocID: 00G00077EB
SPARE PARTS CATALOG DocID: 00G00077EB Table of Contents No. UNIT PART NUMBER SERIAL NUMBER RANGE REFRIGERANT SECTION 1 GX8000-711 GX8000-710 007XXXX180 to Present (From April 2007 to Present) R10A Page
More informationLG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units
Universal and Multi Split Units If there is a fault on any LG Universal or Multi unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller
More informationThis air conditioner uses new refrigerant HFC (R410A).
This air conditioner uses new refrigerant HFC (R40A). 5 cm or over The basic installation work procedures are the same as conventional refrigerant models. However, pay careful attention to the following
More informationSPARE PARTS CATALOG OFFICE PRO 24
SPARE PARTS CATALOG Table of Contents No. UNIT PART NUMBER SERIAL NUMBER RANGE REFRIGERANT SECTION 1 GX484000-681 GX484000-680 0407XXXX240 to Present R410A Page to 1 SP0025-02 2 LA484000-410 LA484000-290
More informationSPARE PARTS CATALOG OFFICE PRO 60
SPARE PARTS CATALOG Table of Contents No. UNIT PART NUMBER SERIAL NUMBER RANGE REFRIGERANT SECTION 1 GX484000-3691 GX484000-3690 0407XXXX600 to Present (From April 2007 to Present) R410A Page 3 to 13 SP0010-03
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on
More informationNo Operation of air conditioner Explanation
12. Troubleshooting 12-1 Items to be checked first 1. The input voltage should be rating voltage ±10% range. The air conditioner may not operate properly if the voltage is out of this range. 2. Is the
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics
More informationBRIVIS DUCTED INVERTER SERVICE MANUAL DRCi
BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi 1 TABLE OF CONTENTS TABLE OF CONTENTS... 2 IMPORTANT NOTE... 3 FAULT FINDING AND DIAGNOSTICS... 3 ABBREVIATIONS... 3 PCB S... 4 OUTDOOR MAIN PCB... 4 INDOOR PCB...
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9
More informationLUV INVERTER SERIES. Self-diagnostics and Trouble-shooting. Part 2 of 2 42/38LUV028H 42/38LUV035H 42/38LUV052H 42/38LUV065H 42/38LUV070H 42/38LUV080H
LUV INVERTER SERIES Part 2 of 2 Self-diagnostics and Trouble-shooting 42/38LUV028H 42/38LUV035H 42/38LUV052H 42/38LUV065H 42/38LUV070H 42/38LUV080H MAJOR COMPONENT CHECKING COMPRESSOR Use a multi-meter
More information8. DISASSEMBLY ILLUSTRATION & PARTS LIST
8. DISASSEMBLY ILLUSTRATION & PARTS LIST 8. DISASSEMBLY ILLUSTRATION & PARTS LIST 8-1 OUTDOOR UNIT Model : AJ*144LALH ( : & A) AJ*126LALH ( : & A) 1 37 38 32 33 3 34 12 4 2 21 5 13 8 15 9 30 28 6 29 11
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES
(791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely
More information6. Troubleshooting. 6-1 Basic items for trouble shooting. Samsung Electronics 17
6. Troubleshooting Since the inverter air conditioner is equipped with Electrical control circuits at both Indoor & outdoor unit, the trouble shooting shall be performed according to the error mode. Inside
More informationtechnical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air
technical data RXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human
More informationParts Lists. Forward Series. Rev. Feb. 2017
s HSU09VHJ(DB)-G / HSU09VHJ(DB)-W HSU12VHJ(DB)-G / HSU12VHJ(DB)-W HSU18VHJ(DB)-G / HSU18VHJ(DB)-W HSU24VHJ(DB)-G / HSU24VHJ(DB)-W 1800 Valley Road Wayne, NJ 07470 Tel +973.617.1800 www.haier.com - Edition
More informationDriftsinstruks. Utopia kontroller feilkoder PCP-2HTE og PC-ART. Vi håper de får stor glede av et Novema kulde produkt!
Driftsinstruks Utopia kontroller feilkoder PCP-2HTE og PC-ART Vi håper de får stor glede av et vema kulde produkt! www.novemakulde.no 8/14 TROUBLESHOOTING 8.2. TROUBLESHOOTING PROCEDURE 8.2.1. ALARM CODE
More information4.Failure phenomenon. Mirage comes out from indoor. When the cold air from AC cools the indoor air. unit
4.Failure phenomenon Phenomenon Mirage comes out from indoor unit Noise Sometimes, the room is smelly when heating, there is no wind at the beginning of starting unit Causing explanation When the cold
More informationSERVICE MANUAL R407C SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS. August No.OC336. Outdoor unit [model names]
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS August 00 No.OC SERVICE MANUAL R07C Outdoor unit [model names] PUH-PVGAA PUH-PVGAA PU-PVGAA [Service Ref.] Service Ref. is on page. This
More informationFRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH
FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 8 MBH TO 4000 MBH TAbLE Of CONTENTs NOMENCLATURE............................. 3 features.................................... 4 KV series features.........................
More informationLG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units
Universal and Multi Split Units If there is fault on any LG universal or multi unit a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the
More informationGCL Technical Manual. Split System Air Conditioner GCL TAC 640. Electronic Control. Air Conditioners
GCL 513-2651-5 Technical Manual Split System Air Conditioner GCL 3-55 TAC 64 Electronic Control Air Conditioners Contents A. Preface... 1-2 TRODUCTION... 1-2 1. GALAXY LE GENERAL DESCRIPTION... 1-3 1.1
More informationSPARE PARTS CATALOG OFFICE PRO 60
SPARE PARTS CATALOG Table of Contents No. UNIT PART NUMBER PRODUCTION PERIOD REFRI- GERANT SECTION ISSUE DATE (mm/ yy) 1 GX484000-3690 FROM April 2007 (0407) TO Present R410A SP0010-01 Page 3 ~ 13 04/
More informationAIR-CONDITIONER SERVICE MANUAL. RBM-Y1034F-PE (3-way) 3-PIPE SUPER MULTI, HEAT PUMP WITH SIMULTANEOUS HEATING AND COOLING. RBM-Y1044F-PE (4-way)
FILE NO. A90-9922 SERVICE MANUAL AIR-CONDITIONER Outdoor Unit Multi Controller 2-PIPE SUPER MULTI, HEAT PUMP MAR-M104HTM8-PE RBM-Y1034-PE (3-way) RBM-Y1044-PE (4-way) 3-PIPE SUPER MULTI, HEAT PUMP WITH
More informationReplacement Parts Catalog
GA Ductfree Series Mini-Split Systems Packaged 18,000-42,000 Terminal BTUH Air Conditioner / Heat Pump 7,000 --- 15,000 BTUH Replacement Parts Catalog 1 Table of Contents Model Number Description Page
More informationPH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C
PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5
More informationNo. F ISSUED: Jul. 1, 2010 REVISED: Nov. 26, 2013 HOSHIZAKI MODULAR CRESCENT CUBER KMD-270AA MODEL
No. F049-3353 ISSUED: Jul. 1, 2010 REVISED: Nov. 26, 2013 HOSHIZAKI MODULAR CRESCENT CUBER MODEL KMD-270AA S LIST (GENERAL) V-1 JUL. 2010 A-2 APR. 2011 AUXILIARY CODE U - 1 The auxiliary code is the first
More informationFRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH
FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 8 MBH TO 4000 MBH TABLE OF CONTENTS NOMENCLATURE............................. 3 FEATURES.................................... 4 KV SERIES FEATURES.........................
More informationKSID MINI Split DC Inverter QUICK CONNECT Air Conditioner TROUBLESHOOTING KSID016-H215Q. Model Numbers:
KSID MINI Split DC Inverter QUICK CONNECT Air Conditioner TROUBLESHOOTING Model Numbers: KSID012-H115Q KSID022-H215Q KSID016-H215Q WARNING Installation MUST conform with local building codes or, in the
More informationPCB COMMERCIAL SERIES
PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner
More information3. SERVICE TOOLS Inverter checker RSUK09-17 CLIMATE COMFORT. All Seasons. Heating. Air Conditioning. Applied Systems.
All Seasons CLIMATE COMFORT Heating 3. SERVICE TOOLS 3.2. Inverter checker RSUK09-17 Air Conditioning Applied Systems Refrigeration 3.2. Inverter checker RSUK09-17: index 1. Outlook 2. How to connect?
More informationMcQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001
Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied
More informationQUARTZ INVERTER TROUBLESHOOTING GUIDE
QUARTZ INVERTER TROUBLESHOOTING GUIDE QIN415H2V31 QIN618H2V31 QIN721H2V31 QIN1129H2V31 INVERTER MINI SPLIT SYSTEM WARNING The information contained in the manual is intended for use by a qualified service
More informationSERVICE MANUAL OUTDOOR UNIT. No. OB386
SPLIT-TYPE AIR CONDITIONERS Revision D: MU-A20VB- E and MU-A5VB- E have been added. Please void OB86 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A No. OB86 REVISED EDITION-D Models MU-A20VB-
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSH1BF Series M1200 Product Line Ultra High Efficiency Heat Pumps 16 SEER 2-5 Ton Capacity The PSH1BF Series of Maytag heat pumps offers exceptional performance as well as
More informationPREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, COOLING SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)
www.source1parts.com HVAC SERVICE PARTS PREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, COOLING SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS) Supersedes: Nothing 035-23394-001 Rev. A (0912) 1 of 16 Figure
More informationSERVICE MANUAL TAC-600 SPARE PARTS FOR AIR CONDITIONER MODELS ANS ANS 50 ANS 60 ANS 65 ANS 77 ANS OCT ELECTRONIC CONTROL
S TA R T S TO P D A I LY POWER TIMER AIR CON. FILTER START STOP 1 2 3 SLEEP DAILY MODE FAN SWEEP WIRELESS DIGIT AL REMOTE CONTROLLER ANS 51302651021 SERVICE MANUAL SPARE PARTS FOR AIR CONDITIONER MODELS
More informationDaikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008
Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationNME950 & FME1200 SERVICE PARTS
NME0 & FME00 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number in question to be sure that it is applicable to this parts list. Note that
More informationSPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE
TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More informationR22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]
R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1
More informationLX SERIES 16 SEER MULTI-SPLIT DUCTLESS, HEAT PUMPS
LX SERIES 16 SEER MULTI-SPLIT DUCTLESS, HEAT PUMPS www.source1parts.com HVAC SERVICE PARTS Supersedes: Nothing 035-23403-001 Rev. A (0912) 1 of 10 Figure 1: MULTI-SPLIT DUCTLESS SYSTEM Outdoor Model Number
More informationTechnical Service Manual
Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........
More informationSingle and Multi-Zone Ductless Inverter Split Systems. MZI Series. Replacement Parts Manual
Presents Single and Multi-Zone Ductless Inverter Split Systems MZI Series Replacement Parts Manual Air Handler (Indoor) Models: MWHA Condenser (Outdoor) Models: MHA/B Ordering Instructions Order Parts
More informationReplacement Parts Catalog
GA Ductfree SeriesMini-Split Systems Packaged 9,000-24,000 Terminal BtuhAir Conditioner /Heat Pump 7,000 --- 15,000 Btuh Replacement Parts Catalog Table of Contents..... Model Number Description Page GWH09AB-A3DNA1B-I
More informationCHP
Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level
More informationSPARE PARTS CATALOG OFFICE PRO W20
SPARE PARTS CATALOG DocID: 00G0007E Table of Contents No. UNIT PART NUMBER PRODUCTION PERIOD REFRI- GERANT SECTION ISSUE DATE (mm/ yy) 1 GX484000-420 FROM January 2011 (0111) TO Present R410-A Page ~ 15
More informationSVC Manual (Exploded View)
SVC Manual (Exploded View) TYPE : WALL MOUNTED Applied Models : M09YJ M12YJ M09CJ M12CJ FAC P/no : 960-920-00 Product Specifications FAC Model Name System M09CJ M12CJ M09YJ M12YJ Outdoor Unit MR09C1J MR12C1J
More informationSplit-Sky Air RMX-JZ Super Multi Plus
TECHNICAL DATA Split-Sky Air RMX-JZ Super Multi Plus Split Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential
More informationPREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, HEAT PUMP SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)
www.source1parts.com HVAC SERVICE PARTS PREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, HEAT PUMP SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS) Supersedes: 035-23395-001 Rev. E (1213) 035-23395-001 Rev. F
More informationPREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, HEAT PUMP SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)
www.source1parts.com HVAC SERVICE PARTS PREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, HEAT PUMP SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS) Supersedes: 035-23395-001 Rev. B (1212) 035-23395-001 Rev. C
More informationParts Lists. Novel Series. Rev. Feb. 2017
s HSU09VHG(DB)-G / HSU09VHG(DB)-W HSU12VHG(DB)-G / HSU12VHG(DB)-W HSU18VHG(DB)-G / HSU18VHG(DB)-W HSU24VHG(DB)-G / HSU24VHG(DB)-W 1800 Valley Road Wayne, NJ 07470 Tel +973.617.1800 www.haier.com - Edition
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2013.12 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics
More information40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw
LLOYD'S REGISTER QUALITY ASSURANCE Direct expansion split system Inverter Cassette I S O 9 00 1 40KQV Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw 40KQV cassette belongs
More informationFDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E
R407C TECHNICAL MANUAL Split Systems Air Conditioner Ducted Blower D & E Series FDMP-D, FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E series Cooling only & Heatpump [50Hz] Table of Contents Table of Contents
More informationMDT5N25 & MTD5N40 SERVICE PARTS
MDTN & MTDN0 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts
More informationLIGHT COMMERCIAL. Troublesooting
LIGHT COMMERCIAL Troublesooting 2. 2.1 Display board 2.1.1 Icon explanation on indoor display board (Super slim cassette 24K). 2.1.2 Icon explanation on indoor display board (Compact cassette 12K, 18K).
More information5. Exploded Views and Parts List 5-1 Indoor Unit
5. Exploded Views and Parts List 5-1 Indoor Unit 5-1 Exploded Views and Parts List Parts List No. Code No. Description Specification 1 Q TY AQV18VBAN AQV18VSAN AQV24VBAN AQV24VSAN DB92-00926C ASSY PANEL
More informationDC INVERTER DUCTED AIR CONDITIONERS
DC INVERTER DUCTED AIR CONDITIONERS DC Inverter Ducted Air Conditioners Technology. With over 5% of revenue invested in research and development programs, Hitachi has developed world leading technologies
More informationC1448, C1848, C2148 Service Parts
C8, C88, C8 Service Parts This part list contains the service parts for the air cooled, water cooled and remote air cooled C8, C88, C8 ice machines. To avoid costly and time consuming errors, double check
More informationEclipse 2000 Service Parts
This part list contains the service parts for the Eclipse 000 systems. The models that are covered include: CME08 CP08 ERC08 Eclipse 000 Service Parts Table of Contents CME08 Cabinet Page CME08 Interior
More informationSERVICE Manual AIR CONDITIONER OUTDOOR UNIT UM27B1C3 INDOOR UNIT AM27B1C07 AM27B1C Installation. 2. Disassembly and Reassembly
ROOM AIR CONDITIONER INDOOR UNIT AM27BC07 AM27BC3 OUTDOOR UNIT UM27BC3 SERVICE Manual AIR CONDITIONER. Installation CONTENTS 2. Disassembly and Reassembly 3. Troubleshooting 4. Exploded Views and Parts
More informationROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh
ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered
More informationVT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY
TECHNICAL SPECIFICATIONS VT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The VT4BE Series now offers the choice of a heat pump that uses a more efficient and
More information14 EXPLODED DIAGRAM/PARTS LIST. SMMS-i OUTDOOR UNIT MMY-MAP0804HT8P, MMY-MAP1004HT8P, MMY-MAP1204HT8P
4 EXPLODED DIAGRAM/PARTS LIST SMMS-i OUTDOOR UNIT MMY-MAP0804, MMY-MAP004, MMY-MAP04 035 00 00 0 064 065 004 058 037 053 036 003 06 059 007 009 068 077 05 060 055 89 040 00 03 046 050 078 045 046 078 044
More informationtechnical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air
technical data FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette Multi (950mm Split Heat x 950mm) Pump (edited) air conditioning systems Split Sky Air Outdoor Units R40A MXS-DAVMB_E2VB_E7VB Features V i
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606
MODEL-ICE0250, ICE0400, ICE0500, ICE0606 ICE SERIES CUBERS SERVICE PARTS MANUAL Includes 50Hz. Units Ice-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081299-01 Date 6/13 Table Of Contents
More informationMDT5N25 & MTD5N40 SERVICE PARTS
This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts list. MDTNs & MDTN0s have
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2
More informationTECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz
TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections
More informationReplacement Parts Catalog
GA Ductfree SeriesMini-Split Systems Packaged 9,000-24,000 Terminal BtuhAir Conditioner /Heat Pump 7,000 --- 15,000 Btuh Replacement Parts Catalog Table of Contents Model Number Description Page T227S-H209
More informationHoshizaki America, Inc.
Hoshizaki America, Inc. Stackable Crescent Cuber Models A Superior Degree of Reliability PARTS LIST www.hoshizaki.com Number: 71332 Issued: 7-7-2011 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...
More informationZHA/ZHB SERIES WARNING
Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8
More information