VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

Size: px
Start display at page:

Download "VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series"

Transcription

1 VRF Indoor Unit 50Hz Type: Wall Mounted M Series Wall Mounted S Series

2 Contents 01 Wall Mounted M Series 20 Wall Mounted S Series

3 MCAC-VTSM Wall Mounted M Series Wall Mounted M Series 1. Features Specifications Dimensions Piping Diagrams Wiring Diagrams Capacity Tables Electrical Characteristics Sound Levels Accessories

4 Wall Mounted M Series MCAC-VTSM Features Various selection Three styles of panels to choose. M9 panel (standard) M3 panel M10 panel Flexible installation Multi-refrigerant outlet pipe method: left\right\rear, more flexible for installation. Flexsible piping connection Refrigerant piping and condensate piping on the same side High efficiency DC fan motor The power consumption of DC driven VRF indoor units can be reduced up to 30% in comparison to corresponding AC type. Quiet operation Adoption of the 2000 stages element positioning mechanical expansion valve, ensures precise flow control, as well as lower modulation noise when EXV operating. More smooth airflow with less turbulence. Owing to the multiple-blade fan and the air guide design, the airflow is getting smoother and more comfortable. 2

5 MCAC-VTSM Specifications Wall Mounted M Series Model MI-22G/DHN1-M MI-28G/DHN1-M MI-36G/DHN1-M MI-45G/DHN1-M Power supply V- Ph-Hz V~50Hz Capacity kw Cooling Input W Rated current A Capacity kw Heating Input W Rated current A Model WZDK20-38G WZDK20-38G ZKSP ZKSP Indoor fan motor Type DC motor Input W Number of rows Tube pitch row pitch mm Indoor coil Fin spacing mm 1.3 Fin type Hydrophilic aluminum Piping diameter mm Ф7 Length height mm Number of circuits Indoor air flow (H/M/L) m 3 /h 422/393/ /370/ /573/ /507/424 Indoor noise level (H/M/L) db(a) 31/30/29 31/30/29 33/32/30 35/33/31 Dimension (W H D) mm Indoor unit Packing (W H D) mm Net/Gross weight kg 8.4/ / / /16.9 Refrigerant type R410A Throttle Type Electronic expansion valve Design pressure (H/L) MPa 4.4/2.6 Liquid pipe/ Gas pipe mm Ф6.35/ Ф12.7 Connecting wiring Power wiring mm Signal wiring mm Drainage water pipe diameter mm Ф16.5 Controller Wireless remote controller Notes: Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB; outdoor temperature: 35 CDB, equivalent ref. piping: 8m (horizontal) Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB; equivalent ref. piping: 8m (horizontal) 3

6 Wall Mounted M Series MCAC-VTSM Specifications Model MI-56G/DHN1-M MI-71G/DHN1-M MI-80G/DHN1-M MI-90G/DHN1-M Power supply V- Ph-Hz V~50Hz Capacity kw Cooling Input W Rated current A Capacity kw Heating Input W Rated current A Model ZKSP ZKSP ZKSP ZKSP Indoor fan motor Type DC motor Input W Number of rows Tube pitch row pitch mm Indoor coil Fin spacing mm 1.3 Fin type Hydrophilic aluminum Piping diameter mm Ф7 Length height mm Number of circuits 5 Indoor air flow (H/M/L) m 3 /h 747/648/ /1005/ /1005/ /1067/867 Indoor noise level (H/M/L) db(a) 38/36/34 44/39/36 44/39/36 48/43/38 Dimension (W H D) mm Indoor unit Packing (W H D) mm Net/Gross weight kg 12.8/ / / /22.4 Refrigerant type R410A Throttle Type Electronic expansion valve Design pressure (H/L) MPa 4.4/2.6 Liquid pipe/ Gas pipe mm Ф9.53/ Ф15.9 Connecting wiring Power wiring mm Signal wiring mm Drainage water pipe diameter mm Ф16.5 Controller Wireless remote controller Notes: Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB; outdoor temperature: 35 CDB, equivalent ref. piping: 8m (horizontal) Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB; equivalent ref. piping: 8m (horizontal) 4

7 MCAC-VTSM Dimensions MI-22G/DHN1-M, MI-28G/DHN1-M Wall Mounted M Series MI-36G/DHN1-M, MI-45G/DHN1-M, MI-56G/DHN1-M MI-71G/DHN1-M, MI-80G/DHN1-M, MI-90G/DHN1-M 5

8 Wall Mounted M Series 4. Piping Diagrams MCAC-VTSM motor fan T2B flare nut T1 T2 EXV gas side heat exchanger flare nut liquid side T1: Indoor ambient temperature sensor; T2: Temperature sensor in the middle of evaporator; T2B: Evaporator outlet temperature sensor. Refrigerant pipe connection port diameters Model Gas pipe Liquid pipe kW Φ12.7 Φ kW Φ15.9 Φ9.53 6

9 (E) MCAC-VTSM Wall Mounted M Series 5. Wiring Diagrams MI-22G/DHN1-M, MI-28G/DHN1-M T1 T2 T2B GM PMV Wire controller Y/G WHITE BLACK XS1 XP1 BLUE XS2 XP2 XS3 XP3 XP5 XS5 New display panel XS4 XP4 CN2 CN3 CN18 CN6 maincontrolboard CN17 SW3 CN16 CN10 CN4 CN8 CN11 POWER ENC1 CN22 CN21 CN1 E Y X CN20 L N P Q E POWER IN SW6 CN24 P Q Y X CN19 CN5 CN15 CN12 CN9 To outdoor COMM. BUS To CCM COMM. BUS MI-36G/DHN1-M, MI-45G/DHN1-M, MI-56G/DHN1-M GRAY YELLOW XT2 P Q To outdoor COMM. BUS BLACK BLUE WHITE X Y To CCM COMM. BUS T1 XS1 T2 PMV GM WHITE XP1 BLACK POWER CN15 CN12 XS2 XP2 T2B BLUE CN17 CN16 XS3 XP3 XS5 XP5 CN18 CN11 ENC1 SW3 CN4 CN10 CN5 CN6 SW6 CN9 CN19 maincontrolboard CN3 CN2 Y/G New display panel POWER IN XS4 XP4 Wire controller Y/G XT1 7

10 Wall Mounted M Series Wiring diagrams MI-71G/DHN1-M, MI-80G/DHN1-M, MI-90G/DHN1-M MCAC-VTSM To CCM COMM. BUS X Y WHITE BLUE BLACK SW3 CN1 PMV GM GM To outdoor COMM. BUS T2B T2 T1 XS1 XS3 POWER IN BLUE XT1 XP1 BLACK XS2 XP2 WHITE XP3 Y/G Y/G (E) P Q XT2 CN3 CN2 CN19 BLACK YELLOW GRAY POWER CN17 CN8 CN6 CN4 CN11 ENC1 CN10 CN16 CN7 CN18 maincontrolboard XS5 XP5 SW6 CN9 CN5 CN15CN12 Wire controller XS4 XP4 MR Code definition Code Name Code Name FM Fan motor T2B Evaporator outlet temperature sensor GM Swing motor CS Water level switch PMV EXV XP1-5/XS1-5 Connectors T1 Indoor ambient temperature sensor XT1/XT2 Terminals T2 Temperature sensor in the middle of evaporator MR Magnetic ring Dial switch setting ON Means 0 ON Means 1 SW1 setting 0 means auto addressing mode (Default) means factory test mod SW2 setting 00 means when temperature is 15 C or below, fan will stop to prevent cold air(default) 01 means when temperature is 20 C or below, fan will stop to prevent cold air 10 means when temperature is 24 C or below, fan will stop to prevent cold air means when temperature is 26 C or below, fan will stop to prevent cold air 8

11 MCAC-VTSM Dial switch setting SW2 setting 1234 SW5 setting SW5 ON 12 SW6 setting Wall Mounted M Series 00 means in heating mode, the fan which stop for reaching the set temp., will periodically stop for 4 minutes and run for 1 minute (Default) 01 means in heating mode, the fan which stop for reaching the set temp., will periodically stop for 8 minutes and run for 1 minute 10 means in heating mode, the fan which stop for reaching the set temp., will periodically stop for 12 minutes and run for 1 minute 11 means in heating mode, the fan which stop for reaching the set temp., will periodically stop for 16 minutes and run for 1 minute 00 means temperature compensation value is 6 o C in heating mode (default) 01 means temperature compensation value is 2 o C in heating mode 10 means temperature compensation value is 4 o C in heating mode 11 means temperature compensation value is 8 o C in heating mode SW6 ON 0 means temperature compensation value is 0 o C in cooling mode (default) 1 means temperature compensation value is 2 o C in cooling mode J1 definition With auto restart function Non-auto restart function 9

12 Wall Mounted M Series 6. Capacity Tables 6.1 Cooling capacity tables TC: Total Capacity; SC: Sensible Capacity Indoor Unit size (kw) Outdoor temperature ( DB) MCAC-VTSM Indoor temperature ( WB/DB) 14/20 16/23 18/26 19/27 20/28 22/30 24/32 TC SC TC SC TC SC TC SC TC SC TC SC TC SC kw kw kw kw kw kw kw kw kw kw kw kw kw kw

13 MCAC-VTSM Cooling capacity tables TC: Total Capacity; SC: Sensible Capacity Indoor Unit size (kw) Outdoor temperature ( DB) 11 Wall Mounted M Series Indoor temperature ( WB/DB) 14/20 16/23 18/26 19/27 20/28 22/30 24/32 TC SC TC SC TC SC TC SC TC SC TC SC TC SC kw kw kw kw kw kw kw kw kw kw kw kw kw kw

14 Wall Mounted M Series MCAC-VTSM Indoor Unit size (kw) Outdoor temperature ( DB) Indoor temperature ( WB/DB) 14/20 16/23 18/26 19/27 20/28 22/30 24/32 TC SC TC SC TC SC TC SC TC SC TC SC TC SC kw kw kw kw kw kw kw kw kw kw kw kw kw kw

15 MCAC-VTSM Heating capacity tables TC: Total Capacity; WB: Wet-bulb temperature; DB: Dry-bulb temperature Indoor Unit size (kw) Outdoor temperature ( ) 13 Wall Mounted M Series Indoor temperature ( DB) TC TC TC TC TC TC WB DB kw kw kw kw kw kw

16 Wall Mounted M Series Heating capacity tables Indoor Unit size (kw) Outdoor temperature ( ) 14 MCAC-VTSM TC: Total Capacity; WB: Wet-bulb temperature; DB: Dry-bulb temperature Indoor temperature ( DB) TC TC TC TC TC TC WB DB kw kw kw kw kw kw

17 MCAC-VTSM Wall Mounted M Series Indoor Unit size (kw) Outdoor temperature ( ) Indoor temperature ( DB) TC TC TC TC TC TC WB DB kw kw kw kw kw kw

18 Wall Mounted M Series 7. Electrical Characteristics MCAC-VTSM Model Indoor Unit Power Supply IFM Hz Voltage Min. Max. MCA MFA KW FLA MI-22G/DHN1-M 50/ MI-28G/DHN1-M 50/ MI-36G/DHN1-M 50/ MI-45G/DHN1-M 50/ MI-56G/DHN1-M 50/ MI-71G/DHN1-M 50/ MI-80G/DHN1-M 50/ MI-90G/DHN1-M 50/ Remark: MCA: Min. Current Amps. (A); MFA: Max. Fuse Amps. (A); KW: Fan Motor Rated Output (kw) FLA: Full Load Amps. (A); IFM: Indoor Fan Motor 16

19 MCAC-VTSM Sound Levels Test condition Wall Mounted M Series Note: 1. Sound values are measured in a semi-anechoic room, at a position 1m below the air outlet both horizontally and vertically. 2. During actual operation, these values are normally somewhat higher as a result of ambient conditions. Sound pressure levels Model Sound test value db(a) H M L MI-22G/DHN1-M MI-28G/DHN1-M MI-36G/DHN1-M MI-45G/DHN1-M MI-56G/DHN1-M MI-71G/DHN1-M MI-80G/DHN1-M MI-90G/DHN1-M

20 Wall Mounted M Series Octave band level MI-22G/DHN1-M, MI-28G/DHN1-M MI-36G/DHN1-M MCAC-VTSM Sound pressure level db(0db=0.0002μ bar) Audibility limits of continuous white sound Sound pressure level db(0db=0.0002μ bar) Audibility limits of continuous white sound Octave band center frequency(hz) Octave band center frequency(hz) MI-45G/DHN1-M MI-56G/DHN1-M Sound pressure level db(0db=0.0002μ bar) Audibility limits of continuous white sound Sound pressure level db(0db=0.0002μ bar) Audibility limits of continuous white sound Octave band center frequency(hz) Octave band center frequency(hz) MI-71G/DHN1-M, MI-80G/DHN1-M MI-90G/DHN1-M 70 Sound pressure level db(0db=0.0002μ bar) Audibility limits of continuous white sound NC-60 NC-50 NC-40 NC-30 NC Octave band center frequency(hz) 18

21 MCAC-VTSM Accessories Wall Mounted M Series Name Quantity Shape Usage 1. Remote controller manual 1 / / 2. Screw ST for installation board 8 Secure the installation board 3. Plastic expanded tube 8 4. Wrapping tape 1 5. Drain pipe 1 6. Wall conduit cover 1 7. Remote controller (including operation manual) 1 8. Frame 1 Hold the remote controller 9. Mounting screw(st C-H) 2 Installation Holder for remote controller 10. Alkaline dry batteries (AM4) Installation manual Network matching wire 1 The indoor unit which at the terminal of communication system should connect a impedance between port P and port Q. 13. Copper nut 1 Connect piping 19

22 Wall Mounted S Series MCAC-VTSM Wall Mounted S Series 1. Features Specifications Dimensions Piping Diagrams Wiring Diagrams Capacity Tables Electrical Characteristics Sound Levels Accessories

23 MCAC-VTSM Wall Mounted S Series 1. Features 1.1 New panel design, with LED display 1.2 Convenient for installation Multi-refrigerant outlet pipe method: left\right\rear, more flexible for installation. Left Rear Right Longer connection pipe( Gas pipe: 468mm/Liquid pipe: 550mm), more flexible for installation Adopts new type fixing plate, easy for installation and stable. 18-7/16in 21-21/32in 2.2~3.6kw 4.5~5.6kw 21

24 Wall Mounted S Series MCAC-VTSM The EXV is built-in the indoor unit, compact size, and convenient for the installation Reserved socket on main control board for water pump and PCB can be customized if you need water pump function The front panel can be lifted up to max. 65 degree and be removed and maintain, easy access for wiring and service. 1.3 Auxiliary electrical heating type is available. 1.4 Three air flow speed: high/medium/low, double air guides. 1.5 Low noise, creates quiet and comfortable environment Adoption of the Fujikoki brand mechanical expansion valve which has 2000 stages element positioning, ensures precise flow control, as well as lower modulation noise when EXV operating More smooth airflow with less turbulence. Owing to the multiple-blade fan and the air guide design, the airflow is getting smoother and more comfortable Louver s air swing angle can be up to 90º 1.6 Wired/wireless controller is available. RM05/BG(T)E-A wireless remote controller is standard,which can set the indoor units addresses, and wired controller is optional. 1.7 Auto restart When the indoor unit is powered off, it will auto restart when powered on again after 3 minutes and operate in the previous state 22

25 MCAC-VTSM Wall Mounted S Series 2. Specifications Model MDV-D15G/N1-S MDV-D22G/N1-S MDV-D22G/DN1-S MDV-D28G/N1-S Power supply V-Ph-Hz V~, 1Ph, 50Hz Capacity kw Cooling Input W Rated current A Capacity kw Heating Input W Rated current A Electrical heating capacity kw Model YDK9-6A YDK15-6 YDK15-6 YDK15-6 Indoor fan motor Type AC motor Brand Welling Input W 23/21/20 30/24/22 30/24/22 30/24/22 Capacitor μf Speed (h/m/l) r/min 721/678/ /760/ /760/ /760/700 Number of rows Tube pitch row pitch mm Fin spacing mm Indoor Fin type Hydrophilic aluminum coil Tube outside diameter and type mm Ф7 Inner groove tube Length height width mm Number of circuits Indoor air flow (H/M/L) m 3 /h 427/389/ /480/ /480/ /480/430 Indoor noise level (H/M/L) db(a) 33/31/28 35/32/29 35/32/29 35/32/29 Indoor unit Dimension (W H D) mm Packing (W H D) mm Net/Gross weight kg 12.4/ / / /16.8 Refrigerant type Throttle Type Model R410A Electronic expansion valve (Mechanical gear modulation, integrated with the evaporator) EFM-25YGMISZ-6M-A Design pressure(h/l) MPa 4.4/2.6 Refrigerant piping Liquid side/ Gas side mm Ф6.35/ Ф12.7 Connecting wiring Power wiring mm Signal wiring mm Drainage water pipe diameter ODФ16.5 Controller Wireless remote controller Notes: 1. Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature.:35 CDB,equivalent ref. Piping: 8m(horizontal) 2. Nominal heating capacities are based on the following conditions: return air temperature.: 20 CDB,outdoor temp.: 7 CDB,6 CWB,equivalent ref. Piping: 8m(horizontal) kW model is only available for V4 plus and MINI VRF system. 23

26 Wall Mounted S Series MCAC-VTSM Model MDV-D28G/DN1-S MDV-D36G/N1-S MDV-D36G/DN1-S MDV-D45G/N1-S Power supply V- Ph-Hz V~, 1Ph, 50Hz Cooling Heating Capacity kw Input W Rated current A Capacity kw Input W Rated current A Electrical heating capacity kw Indoor fan motor Indoor coil Model YDK15-6 YDK15-6 YDK15-6 YDK18-4 Type Brand AC motor Welling Input W 30/24/22 30/24/22 30/24/22 44/42/39 Capacitor μf Speed (h/m/l) r/min 810/760/ /760/ /760/ /880/760 Number of rows Tube pitch row pitch mm Fin spacing mm Fin type Tube outside diameter and type mm Hydrophilic aluminum Ф7 Inner groove tube Length height width mm Number of circuits Indoor air flow (H/M/L) m 3 /h 525/480/ /520/ /520/ /755/630 Indoor noise level (H/M/L) db(a) 35/32/29 35/32/29 35/32/29 40/38/34 Indoor unit Refrigerant type Throttle Dimension (W H D) mm Packing (W H D) mm Net/Gross weight kg 13.3/ / / /19.5 Type Model R410A Electronic expansion valve (Mechanical gear modulation, Integrated with the evaporator) EFM-25YGMISZ-6M-A Design pressure (H /L) MPa 4.4/2.6 Refrigerant piping Connecting wiring Liquid side/ Gas side Drainage water pipe diameter Controller mm Ф6.35/ Ф12.7 Power wiring mm Signal wiring mm ODФ16.5 Wireless remote controller Notes: 1. Nominal cooling capacities are based on the following conditions: return air temperature. : 27 CDB, 19 CWB, outdoor temperature.:35 CDB,equivalent ref. Piping: 8m(horizontal) 2. Nominal heating capacities are based on the following conditions: return air temperature.: 20 CDB,outdoor temperature.: 7 CDB,6 CWB,equivalent ref. Piping: 8m(horizontal) kW model is only available for V4 plus and MINI VRF system. 24

27 MCAC-VTSM Wall Mounted S Series Model MDV-D45G/DN1-S MDV-D56G/N1-S MDV-D56G/DN1-S Power supply V- Ph-Hz V~, 1Ph, 50Hz Cooling Heating Capacity kw Input W Rated current A Capacity kw Input W Rated current A Electrical heating capacity kw Indoor fan motor Indoor coil Model YDK18-4 YDK18-4 YDK18-4 Type Brand AC motor Welling Input W 44/42/39 44/42/39 44/42/39 Capacitor μf Speed (h/m/l) r/min 980/880/ /880/ /880/760 Number of rows Tube pitch row pitch mm Fin spacing mm Fin type Tube outside diameter and type mm Hydrophilic aluminum Ф7 Inner groove tube Length height width mm Number of circuits Indoor air flow (H/M/L) m 3 /h 860/755/ /860/ /860/755 Indoor noise level (H/M/L) db(a) 40/38/34 40/38/34 40/38/34 Indoor unit Refrigerant type Throttle Dimension (W H D) mm Packing (W H D) mm Net/Gross weight kg 15.5/ / /19.9 Type Model R410A Electronic expansion valve (Mechanical gear modulation, integrated with the evaporator) EFM-25YGMISZ-6M-A Design pressure (H /L) MPa 4.4/2.6 Refrigerant piping Connecting wiring Drainage water pipe diameter Controller Liquid side/ Gas side mm Ф6.35/ Ф12.7 Ф9.53/Ф15.9 Power wiring mm Signal wiring mm ODФ16.5 Wireless remote controller Notes: 1. Nominal cooling capacities are based on the following conditions: return air temperature. : 27 CDB, 19 CWB, outdoor temperature.:35 CDB,equivalent ref. Piping: 8m(horizontal) 2. Nominal heating capacities are based on the following conditions: return air temperature.: 20 CDB,outdoor temperature.: 7 CDB,6 CWB,equivalent ref. Piping: 8m(horizontal) kW model is only available for V4 plus and MINI VRF system. 25

28 Wall Mounted S Series MCAC-VTSM Dimension Outline dimension and air outlet opening size MDV-D15G/N1-S MDV-D22G/N1-S MDV-D28G/N1-S MDV-D36G/N1-S MDV-D22G/DN1-S MDV-D28G/DN1-S MDV-D36G/DN1-S Main dimension: Outer Length: 915mm, Height: 230mm, Depth: 290mm Filter length: 663mm Gas tube: Ф12.7mm, length: Approx. 468mm Liquid tube:ф6.35mm,length: Approx.550mm MDV-D45G/N1-S MDV-D56G/N1-S MDV-D45G/DN1-S MDV-D56G/DN1-S Outer Length: 1072mm, Height: 230mm, Depth: 315mm Filter length: 813mm Gas tube:ф12.7mm, length: Approx. 468mm Liquid tube: Ф9.53 length: Approx.550mm 26

29 MCAC-VTSM Wall Mounted S Series 4. Piping Diagrams MDV-D15G/N1-S MDV-D22G/N1-S MDV-D28G/N1-S MDV-D36G/N1-S MDV-D45G/N1-S MDV-D56G/N1-S MDV-D22G/DN1-S MDV-D28G/DN1-S MDV-D36G/DN1-S MDV-D45G/DN1-S MDV-D56G/DN1-S motor fan T2B flare nut T1 T2 EXV gas side heat exchanger flare nut liquid side 27

30 Wall Mounted Type (S Type) MCAC-VTSM Wiring diagrams MDV-D15G/N1-S MDV-D22G/N1-S MDV-D28G/N1-S MDV-D36G/N1-S MDV-D45G/N1-S MDV-D56G/N1-S MDV-D22G/DN1-S MDV-D28G/DN1-S MDV-D36G/DN1-S MDV-D45G/DN1-S MDV-D56G/DN1-S F X Y (E) P Q (E) TO CCM COMM. BUS TO INDOOR COMM. BUS means factory test mode means auto addressing mode means DC fan is chosen means AC fan is chosen means DC fan static pressure is 0 means DC fan static pressure is 1 1 means DC fan static pressure is 2 11means DC fan static pressure is 3 means shutting down the unit to stop cold air at 15 1 means shutting down the unit to stop cold air at 20 1 means shutting down the unit to stop cold air at means shutting down the unit to stop cold air at 26 means the time of stopping TERMAL fan is 4 mintues means the time of stopping TERMAL fan is 8 mintues 1 11 means old display penal means new display penal means auto air blow under auto mode means auto air blow under non-auto mode reserved without jumper for auto restart function with jumper for non-auto restart function reserved 1 means the time of stopping TERMAL fan is 12 mintues 11 means the time of stopping TERMAL fan is 16 mintues standard configuration last unit of the network means means Note: 1.Power supply of ALARM port is the same with indoor unit. The wire between the alarm port CN6 and alarm element should be customized. 2.ON/OFF port doesn t need power supply. When the port is in short circuit condition, indoor units will stop running and cannot be controlled by the controller. When the port is in disconnect condition, the indoor units will be in normal state. The wire should be customized and within one meter length. 28

31 MCAC-VTSM Wall Mounted S Series 6. Capacity Tables 6.1 Cooling TC: total capacity SC: sensible capacity Indoor Outdoor temperature Unit size ( DB) (kw) WB: wet-bulb temperature DB: dry-bulb temperature Indoor temperature ( WB/DB) 14/20 16/23 18/26 19/27 20/28 22/30 24/32 TC SC TC SC TC SC TC SC TC SC TC SC TC SC kw kw kw kw kw kw kw kw kw kw kw kw kw kw

32 Wall Mounted S Series MCAC-VTSM Indoor Outdoor temperature Unit size ( DB) (kw) Indoor temperature ( WB/DB) 14/20 16/23 18/26 19/27 20/28 22/30 24/32 TC SC TC SC TC SC TC SC TC SC TC SC TC SC kw kw kw kw kw kw kw kw kw kw kw kw kw kw

33 MCAC-VTSM Wall Mounted S Series 6.2 Heating TC: total capacity WB: wet-bulb temperature DB: dry-bulb temperature Indoor Unit size (kw) Outdoor temperature ( ) Indoor temperature ( DB) TC TC TC TC TC TC WB DB kw kw kw kw kw kw

34 Wall Mounted S Series MCAC-VTSM Indoor Unit size (kw) Outdoor temperature ( ) Indoor temperature ( DB) TC TC TC TC TC TC WB DB kw kw kw kw kw kw Note: The above table is only the heat pump heating capacity, for the type with Electrical heater, the total capacity should plus the additional electrical heating capacity, which is a constant data. 32

35 MCAC-VTSM Wall Mounted S Series 7. Electrical Characteristics Model Indoor Unit Power Supply IFM Hz Voltage Min. Max. MCA MFA KW FLA MDV-D15G/N1-S MDV-D22G/N1-S MDV-D28G/N1-S MDV-D36G/N1-S MDV-D45G/N1-S MDV-D56G/N1-S MDV-D22G/DN1-S MDV-D28G/DN1-S MDV-D36G/DN1-S MDV-D45G/DN1-S MDV-D56G/DN1-S Remark: MCA: Min. Current Amps. (A) MFA: Max. Fuse Amps. (A) KW: Fan Motor Rated Output (kw) FLA: Full Load Amps. (A) IFM:Indoor Fan Motor 33

36 Wall Mounted S Series MCAC-VTSM Sound Levels 8.1 Test condition 8.2 Test value 0.8m Model Sound test value db(a) H M L MDV-D15G/N1-S MDV-D22G/(D)N1-S MDV-D28G/(D)N1-S MDV-D36G/(D)N1-S MDV-D45G/(D)N1-S MDV-D56G/(D)N1-S MDV-D15G/N1-S MDV-D22(28/36)G/(D)N1-S Sound pressure level db(0db=0.0002μ bar) Audibility limits of continuous white sound Sound pressure level db(0db=0.0002μ bar) Audibility limits of continuous white sound MDV-D45G/(D)N1-S Octave band center frequency(hz) MDV-D56G/(D)N1-S Octave band center frequency(hz) Sound pressure level db(0db=0.0002μ bar) Audibility limits of continuous white sound Octave band center frequency(hz) 34

37 MCAC-VTSM Wall Mounted S Series 9. Accessories 9.1 Standard accessories Name Quantity Shape Usage Installation manual 1 / / Pipe insulation material 2 Heat insulation Remote controller 1 / 7# alkaline battery 2 / Holder for remote controller 1 Hold the remote controller Remoter controller manual 1 / Mounting screw(st C-H) 2 Installation Holder for remote controller Controlling discreteness installation plot 1 / / Installation spring 2 Fix water outlet Water outlet joint 1 For drainage Wrapping tape 1 / Plastic expanded tube 3 / Screw ST for installation board 3 Secure the installation board Network matching wire 1 The indoor unit which at the terminal of communication system should connect a impedance between port P and port Q. 9.2 Optional accessories Name Model Code Usage Wired controller KJR-10B/DP(T)-E (Follow me) Wired controller KJR-12B/DP(T)-E With a standard 5m long cable to connect to display board. With an extra Built-in room temperature sensor, all others are same as KJR-10B Touch-style Key Wired Controller KJR-29B/BK-E Air filter cleaning remind function,follow me function,indoor unit address setting function 35

38 Wall Mounted C Series MCAC-VTSM Wall Mounted C Series 1. Features Specifications Dimensions Piping Diagrams Wiring Diagrams Capacity Tables Electrical Characteristics Sound Levels Accessories

39 MCAC-VTSM Wall Mounted C Series 1. Features 1.1 Panel with LED display The front panel and display panel have different colors to choose: white and brown for big panel, blue and brown for small panel, and the other colors can be customized according to the customers demands. 1.2 Convenient for installation Multi-refrigerant outlet pipe method: left\right\rear, more flexible for installation. Left Rear Right Longer the connection pipe, Gas pipe: 468mm/Liquid pipe: 550mm, more flexible for the installation Adopts new type fixing plate, easy for installation and stable. 2.2~3.6kw 4.5~5.6kw 37

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams... MCAC-VTSM-2013-08 1. Features... 264 2. Specifications... 265 3. Dimensions... 268 4. Service Spaces... 272 5. Piping Diagrams... 273 6. Wiring Diagrams... 274 7. Capacity Tables... 276 8. Electrical Characteristics...

More information

Compact Four-way Cassette Type

Compact Four-way Cassette Type 1. Features... 34 2. Specifications... 35 3. Dimensions... 37 4. Service Spaces... 38 5. Piping Diagrams (EXV beside)... 39 6. Wiring Diagrams... 40 7. Capacity Tables... 41 8. Electrical Characteristics...

More information

Low Static Pressure Duct (V shape evaporator)

Low Static Pressure Duct (V shape evaporator) MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...

More information

Service manual MIV V4+ Indoor units

Service manual MIV V4+ Indoor units Service manual MIV V4+ Indoor units Floor Standing MVF22A-VA1 MVF28A-VA1 MVF36A-VA1 MV5A-VA1 MVF56A-VA1 MVF71A-VA1 MVF80A-VA1 MVB22A-VA1 MVB28A-VA1 MVB36A-VA1 MVB45A-VA1 MVB56A-VA1 MVB71A-VA1 MVB80A-VA1

More information

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping

More information

Low Static Pressure Duct(V shape evaporator)

Low Static Pressure Duct(V shape evaporator) Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...

More information

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4

More information

Technical Service Manual

Technical Service Manual Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2013.12 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

Engineering Data Book

Engineering Data Book 40VMH High Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

Engineering Data Book

Engineering Data Book 40VMM Medium Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

Four-way Cassette Type

Four-way Cassette Type Four-way Cassette Type Four-way Cassette Type 1. Features... 9 2. Specifications... 12 3. Dimensions... 17 4. Service Space... 18 5. Wiring Diagrams... 19 6. Capacity Tables... 21 7. Electric Characteristics...

More information

Engineering Data Book

Engineering Data Book 40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal

More information

MODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si

MODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si MODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si Part 1 General Information.. 1 Part 2 Indoor Units. Part 3 Outdoor Units. Part 5 Control... Part 6 Control

More information

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three

More information

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1

More information

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the

More information

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has

More information

Cassette 4 Ways FCU DC Service manual

Cassette 4 Ways FCU DC Service manual Cassette Ways FCU DC Service manual MUCS-W7 www.mundoclima.com CL022 to CL02 English Two-pipe Four-way Cassette DC Fan Coil Unit 1. External Appearance... 2 2. Features... 2. Product lineup.... Accessories....

More information

VHIA High-Static Ducted Indoor Units - 60HZ

VHIA High-Static Ducted Indoor Units - 60HZ PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage

More information

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

High Static Pressure Duct Fan Coil Unit

High Static Pressure Duct Fan Coil Unit MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4

More information

Capacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU

Capacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU Cooling Capacity: Remark: EWT: Enter Water Temp. ( ); Δt: Temperature Difference ( ) DB: Dry Bulb Temp. ( ); WB: Wet Bulb Temp. ( ); TC: Total Cooling Capacity (kw); SC: Sensible Cooling Capacity (kw);

More information

Outdoor Units R-410A ARX-GV1B

Outdoor Units R-410A ARX-GV1B Outdoor Units R-40A ARX-GVB t A i n y U k BS r o AV t o0g i d- lt4x pur- SRAO 2 Specifications Outdoor Units R-40A ARX-GVB 2- NOMINAL CAPACITY AND NOMINAL INPUT ARX20GVB ARX25GVB ARX5GVB For combination

More information

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air technical data RXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human

More information

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without incurring

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

High Wall Type ( 2 Series )

High Wall Type ( 2 Series ) Jan.05' Engineering Data High Wall Type ( 2 Series ) Indoor Unit MMK-AP0072H MMK-AP0092H MMK-AP0122H 1. Equipments 2. Technical Specifications 3. Dimensional Drawing 4. Wiring Diagram 5. Refrigerant Cycle

More information

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air technical data RKS-C RKS-B Pair Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help

More information

Bosch Climate 5000 Ductless Minisplit System

Bosch Climate 5000 Ductless Minisplit System Engineering Submittal Sheet Overview and Certifications [single zone only] Standard Features and Field Installed Accessories Standard Features R-410A chlorine-free refrigerant with pre-charge for line

More information

technical data air conditioning systems MXS-B Multi Application Split Sky Air

technical data air conditioning systems MXS-B Multi Application Split Sky Air technical data MXS-B Multi Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment

More information

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................

More information

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Indoor Console Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Black Display Functional art, the touch screen display is elegant

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

FFQN-C, FCRN-E, FFRN-C

FFQN-C, FCRN-E, FFRN-C R410A TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FCQN-E, FFQN-C, FCRN-E, FFRN-C Cooling only & Heatpump [50Hz] DAIKIN_FFRN.indb i 12/27/2012 9:28:06 AM DAIKIN_FFRN.indb ii

More information

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz] R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

VRF. Technical Data Book. DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz)

VRF. Technical Data Book. DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz) VRF Technical Data Book DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz) History Version Modification Date Remark Ver.1.0 Release DVM Indoor PAC for

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information

Vertical Air Handling Unit type

Vertical Air Handling Unit type Vertical Air Handling Unit type Engineering Databook MMD-AP0120VHG2UL MMD-AP0180VHG2UL MMD-AP0240VHG2UL MMD-AP0300VHG2UL MMD-AP0360VHG2UL MMD-AP0420VHG2UL MMD-AP0480VHG2UL MMD-AP0600VHG2UL Contents 1.

More information

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Split Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Indoor Unit FTXC-A TABLE OF CONTENTS FTXC-A 1 Features.............................................................

More information

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps RZQG71L8Y1B RZQG100L8Y1B RZQG125L8Y1B RZQG140L7Y1B Sound pressure level Heating Nom. dba 50 52 53 53 Cooling Nom. dba 48 50 51 52 Night quiet mode Level 1 dba 43 45 45 45 Standard Accessories Item Tie-wraps

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units t i t l r - I Features s e Cs m B ne d E Ue V s 7 ya P os e oc Q dvn S nr ox VF C Reduction of power consumption of 20% (compared to FXSQ-M8 series) through use of new DC fan Improved comfort thanks to

More information

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................

More information

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air technical data MA-GZ7 Multi Model Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect human health

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series Inverter cooling only / heat pump series RSX(Y)P5,8,10K7W1 RSX(Y)P-K7W1 1 Inverter cooling only / heat pump series 1 1 Specifications

More information

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Engineering Data ED-FWW-201501 Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Models: FWW200 FWW300 FWW400 FWW600 FWW800 FWW1000 FWW1200 FWW1400 FWW1600 FWW1800 Air Flow: 360-3020m 3 /h DAIKIN

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

SERVICE MANUAL MIDEA SUPER DC INVERTER MULTI TYPE DC MULTI OUTDOOR UNITS

SERVICE MANUAL MIDEA SUPER DC INVERTER MULTI TYPE DC MULTI OUTDOOR UNITS SERVICE MANUAL MIDEA SUPER DC INVERTER MULTI TYPE DC MULTI OUTDOOR UNITS M2OD-16HFN1-Q M2OD-18HFN1-Q M3OD-21HFN1-Q M3OD-26HFN1-Q M4OD-28HFN1-Q M4OA-36HFN1-Q M5OC-36HFN1-Q M5OD-42HFN1-Q CONTENTS 1. GENERAL

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

SERVICE MANUAL OUTDOOR UNIT. No. OB386

SERVICE MANUAL OUTDOOR UNIT. No. OB386 SPLIT-TYPE AIR CONDITIONERS Revision D: MU-A20VB- E and MU-A5VB- E have been added. Please void OB86 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A No. OB86 REVISED EDITION-D Models MU-A20VB-

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381) FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-

More information

MSP Duct S Specifications

MSP Duct S Specifications MSP Duct S Specifications Model Name AM022FNMDEH AM028FNMDEH AM036HNMPKH AM045HNMPKH AM056HNMPKH Capacity *2) 2.2 2.8 3.6 4.5 5.6 *3) 2.5 3.2 4.0 5.0 6.3 Perfomance (Total) *5) kw 1.8 2.3 2.9 3.7 4.6 VRF

More information

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air technical data RYP-L7/B7 Pair Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the

More information

Split-Sky Air FAYP-B Wall Mounted Unit

Split-Sky Air FAYP-B Wall Mounted Unit TECHNICAL DATA Split-Sky Air FAYP-B Wall Mounted Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential

More information

Concealed Ducted Split Series R22

Concealed Ducted Split Series R22 Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING

More information

Product Catalog. Variable Refrigerant Flow (VRF) VRF-PRC026A-EN. Mid-Static Concealed (Ducted) Indoor Units. November 2015

Product Catalog. Variable Refrigerant Flow (VRF) VRF-PRC026A-EN. Mid-Static Concealed (Ducted) Indoor Units. November 2015 Product Catalog Variable Refrigerant Flow (VRF) Mid-Static Concealed (Ducted) Indoor Units Indoor Unit Model number: 4TVD****C***** November 2015 VRF-PRC026A-EN Introduction Trane variable refrigerant

More information

SERVICE MANUAL OUTDOOR UNIT. No. OB387

SERVICE MANUAL OUTDOOR UNIT. No. OB387 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision C: MUH-A25VB - E has been added. Please void OB87 REVISED EDITION-B. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A. OB87 REVISED EDITION-C Wireless type

More information

DC Inverter 10.0 / 12.5 / 14.0 kw

DC Inverter 10.0 / 12.5 / 14.0 kw DC Inverter 10.0 / 12.5 / 14.0 kw Outdoor Units GC 36 DCI GC 43 DCI GC 60 DCI Indoor Units DLS 36 DCI DHC 36 DCI DLS 43 DCI DHC 43 DCI CD 60 DCI REFRIGERANT R410A HEAT PUMP NOVEMBER 2008 LIST OF EFFECTIVE

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

Part Ⅰ : Technical Information

Part Ⅰ : Technical Information Service Manual Part Ⅰ : 1. Summary Outdoor Unit GWHD(18)NK3JO(DRED) GWHD(24)NK3JO(DRED) GWHD(28)NK3JO(DRED) 1 2. Specifications Model GWHD(18)NK3JO(DRED) Product Code CB228W05900 Rated Voltage V~ 220-240

More information

Fan Coil Units. Technical Data

Fan Coil Units. Technical Data Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Table of Contents Table of Contents 3 Round Flow Cassette...

More information

Multi-Room Ductless heat-pump systems Submittal Data: MULTI18HP230V1AO 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date

Multi-Room Ductless heat-pump systems Submittal Data: MULTI18HP230V1AO 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Multi-Room Ductless heat-pump systems Submittal Data: 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. Reference Approval

More information

Digital Inverter 4 series

Digital Inverter 4 series TCTC-E14-LC005-2 Digital Inverter 4 series Outdoor Unit RAV-SM304ATP-E RAV-SM304ATJP-E RAV-SM4ATP-E RAV-SM4ATJP-E I ndoor Unit RAV-SM307KRTP-E RAV-SM7KRTP-E RAV-SM7CTP-E RAV-SM304MUT-E RAV-SM4MUT-E RAV-SM304SDT-E

More information

Package Air Conditioners

Package Air Conditioners MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment

More information

SERVICE MANUAL MIDEA AIRCONDITIONER SUPER DC INVERTER MULTI TYPE OUTDOOR UNITS

SERVICE MANUAL MIDEA AIRCONDITIONER SUPER DC INVERTER MULTI TYPE OUTDOOR UNITS SERVICE MANUAL MIDEA AIRCONDITIONER SUPER DC INVERTER MULTI TYPE OUTDOOR UNITS M2OE-14HFN1-Q M2OF-18HFN1-Q M3OE-21HFN1-Q M3OE-27HFN1-Q M4OE-28HFN1-Q M4OB-36HFN1-Q M5OE-42HFN1-Q Service manual CONTENTS

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9

More information

SERVICE MANUAL MU-GA20VB- MU-GA20VB- MU-GA25VB- MU-GA25VB- MU-GA35VB- E1 OUTDOOR UNIT. No. OB386. Wireless type Models HFC

SERVICE MANUAL MU-GA20VB- MU-GA20VB- MU-GA25VB- MU-GA25VB- MU-GA35VB- E1 OUTDOOR UNIT. No. OB386. Wireless type Models HFC SPLIT-TYPE, AIR CONDITIONERS Revision B: MU-A20VB- E2 and MU-A25VB - have been added. Please void OB86 REVISED EDITION-A. E2 OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A No. OB86 REVISED EDITION-B Wireless

More information

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS.

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS. SPLIT-TYPE, AIR CONDITIONERS Revision A: MU-A2YV - E can be connected to MCF-A2WV - E. Please void OB330. SERVICE MANUAL Wireless type Models E MU-A07YV - E MU-A09YV - MU-A2YV - E HFC utilized R40A No.

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

VRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH***

VRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH*** VRF Technical Data Book Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH*** History Version Modification Date Remark Ver.1.0 Release Ceiling for America (R410A, 60Hz, HP) 15.11.04 - 1 Nomenclature

More information

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................

More information

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils MHP4 Electric Heat Pump Packaged Thru-the-Wall Units FEATURES Up to 10.4 EER cooling efficiency Completely self-contained heating and cooling package No outside condensing unit No external refrigerant

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2

More information

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit E10-1 High Static Duct 8, 10HP Digital Inverter Engineering Data Book Indoor Unit RAV-SM2242DT-E RAV-SM2802DT-E RAV-SM2242DT-TR RAV-SM2802DT-TR Outdoor Unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents 1 Specifications..............................................................

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8

More information

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE Indoor unit AGYF09LAC AGYFLAC AGYFLAC AGYFLAC Outdoor unit AOYV09LAC AOYVLAC AOYVLAC AOYVLAL CONTENTS SPECIFICATIONS..................... DIMENSIONS.........................

More information

Refrigeration copper tube aluminum fin evaporator

Refrigeration copper tube aluminum fin evaporator Hangzhou Ponray Technologies Co., Ltd Add: Rm1903,Keda Touzi Bldg, No.555,Xincheng Rd,Binjiang,Hangzhou,China Tel: 0086-571-86433485 Fax:0086-571-86433481 P.I.C.: Richard Zeng Web: www.fridgtec.com E-mail:

More information

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425) ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV

More information

MCE4 FEATURES REFRIGERANT SYSTEM CABINET BLOWER CONTROLS INSTALLATION WARRANTY. Electric Heating / Electric Cooling Packaged Units

MCE4 FEATURES REFRIGERANT SYSTEM CABINET BLOWER CONTROLS INSTALLATION WARRANTY. Electric Heating / Electric Cooling Packaged Units Electric Heating / Electric Cooling Packaged Units FORM NO. -100 (06/2017) FEATURES Up to 10.0 EER cooling efficiency Less than 2% cabinet air leakage Completely self-contained heating and cooling package

More information

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit E0--2 High Static Duct 8, 0HP Digital Inverter Engineering Data Book Indoor Unit RAV-SM2242DT-E RAV-SM2802DT-E RAV-SM2242DT-TR RAV-SM2802DT-TR Outdoor Unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents Specifications..............................................................

More information

Split-Sky Air RMX-JZ Super Multi Plus

Split-Sky Air RMX-JZ Super Multi Plus TECHNICAL DATA Split-Sky Air RMX-JZ Super Multi Plus Split Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential

More information

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors

More information

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) SINGLE Technical Data Book 4Way Cassette S for Nordic (R4A, 5Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) History Version Modification Date Remark Ver.1. Released SINGLE for Nordic TDB 15.3.. Ver.1.1

More information

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air

More information

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units MCE4 Electric Heating / Electric Cooling Packaged Thru-the-Wall Units Form No.: MCE4-100 (07/2011) features Up to 10.4 EER cooling efficiency Completely self-contained heating and cooling package No outside

More information

CHILLED WATER FAN-COIL UNITS

CHILLED WATER FAN-COIL UNITS 40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in

More information

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h Cooling Capacity: 23,000-56,000 BTU/h GPC14M Packaged Air Conditioner 2 through 5 Tons / 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heat

More information