PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

Size: px
Start display at page:

Download "PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A"

Transcription

1 PCXAU161 VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ Heat Pump 5/6 Hz R-1A

2 An industry first, the VRV air handling unit has been designed and engineered by Daikin to create new opportunities for applying VRV into retail, offices, cinemas and coercial applications with large open spaces. Airport Lobby Hospital Available in two types, Standard Series or Outdoor Air Series from 6HP to 6HP Daikin s VRV AHU are paired with VRV IV Heat Pump outdoor units for superior EER & COP performance Harnesses all features of VRV IV Heat Pump including Variable Refrigerant Technology (VRT)*, Daikin s Inverter Technology and connection to building management systems. ESP of up to 5 enables flexible ductwork design Ultimate installation flexibility Double skin with either 5 or 5 thick PU insulated panels with thermal break options. Long pipe runs of up to 165m** Custom configurations are also available to suit site constraints *Only applies to Standard Series models **Only applies to Standard Series models, Outdoor Air Series models allow only up to 5m pipe runs STANDARD SERIES Airflow Range: 9-7,8 L/s Capacity Range: OUTDOOR AIR SERIES Airflow Range: 566-,55 L/s Capacity Range: Factory Shopping Mall Sports Hall Showroom Warehouse

3 VRV AHU System Structure Options Wide ranges of options are available to meet your design requirement. Please contact Daikin s sales office regarding below mentioned options: Fan type Backward curved Airfoil curved Plug fan - AC/EC Type Motor IE IE3 Explosion Proof Flame Proof AHU fin material Copper Blue fin Heresite coating AHU coil frame Stainless steel AHU drain pan type (G-HI) Powder coated galvanised iron (GI) AHU air filter type Extra filter Synthetic Bag HEPA Carbon Cartridge Special option Mixing box Outdoor roof Aluminium, stainless steel or GI panels Heat Pipe Heat recovery component Custom paint options on the casing panels VFD for motor Customization Air flow Capacity ESP Discharge direction Piping outlet Dimension Note: For Outdoor Air Series models, H1 = 3m & Longest Pipe Length = a +b + c + d = 5m

4 Standard Series AHUR-CAVJ/DAVJ/DABVJ The VRV AHU standard series are available from the capacity range of 6HP to 6HP, also with airflow ranging from 3, CMH - 8,8 CMH. 8 Daikin Standard Series PCB EKEQMCBA VRV AHU AHUR-CAVJ/DAVJ/DABVJ operation is similiar as other VRV indoor unit. Following table is the list of operation range limit for AHU unit. Ambient Temperature Cooling Heating ºC DB / 1ºC WB 1ºC DB AHUR-CAVJ/DAVJ/DABVJ standard series model use DX coil. Each DX coil will be connected to one external expansion valve (EKEXV) and controlled by one Standard Series PCB (EKEQMCBA). 3ºC DB / ºC WB ºC DB VRV IV -5ºC DB -ºC WB 9ºC DB 15.5ºC WB -1ºC WB ºC DB Standard Series PCB (EKEQMCBA)

5 NOTE: VRV AHU Standard Series can only be applied as a multi system and Not as a single pair (AHU + Outdoor Combination) Standard Series AHUR-CAVJ/DAVJ/DABVJ Standard Series AHUR-CAVJ/DAVJ/DABVJ * For AHU more than 6 HP capacity, alternative option is available. * In case of more than 6 HP system, connection is multiple VRV system.

6 Standard Series AHUR-CAVJ/DAVJ/DABVJ Standard Series AHUR-CAVJ/DAVJ/DABVJ MODEL NAME: 1 CASING Metal Insulation CASING FRAME 3 COIL Tube Fin Header Frame Working Pressure FAN Type Wheel Housing Frame 5 MOTOR 6 VIBRATION ISOLATOR 7 DRAIN PAN 8 AIR FILTER Pre Filter Size 9 STANDARD SERIES PCB 1 EXPANSION VALVE AHUR_CAVJ / AHUR_DAVJ / AHUR_DABVJ AHUR_CAVJ : 5 Thickness Double Skinned nel AHUR_DAVJ : 5 Thickness Double Skinned nel AHUR_DABVJ : 5 Thickness Double Skinned nel (Thermal Break).5 Thickness White Color Bond Galvanized Steel Sheet 5 / 5 Thickness Polyurethane Foam kg/m 3 Density Aluminum Profile Frame (5 and 5) / Aluminium Profile Frame with Nylon (5 thermal break) DX Coil Copper Tube Aluminum Copper Tube Connect Galvanized Steel 1 kg/cm G or below Double Inlet Centrifugal Belt Driven Fan Galvanized Steel Sheet Galvanized Steel Sheet Galvanized Angular Bars Three-Phase Induction Motor Totally Enclosed Fan-Cooled Type Protection = IP55, Insulation Class = F, Efficiency: IE3 For fan size 355 and below, rubber mounting For fan size and above, spring isolator 1. Stainless Steel 3, external cover with 1 PE foam Type = R9, Class = G3, Synthetic washable x x, 1 x x EKEQMCBAV3 & Motor Starter nel EKEXV1, EKEXV, EKEXV5, EKEXV, EKEXV5 * For unit to be installed outdoor, roof option (epoxy powder coated) is available, please contact Daikin s Sales Office. Drawings and Dimension of AHU Dimension W x D x H () AHUR6-CAVJ 11 X 15 x 88 AHUR8-CAVJ 1 X 15 x 88 AHUR1-CAVJ 1 X 15 x 88 AHUR16-CAVJ 1 X 16 x 118 AHUR-CAVJ 1 X 16 x 18 AHUR3-CAVJ 19 X 19 x 18 AHUR-CAVJ 19 X x 178 AHUR8-CAVJ 3 X x 178 AHUR6-CAVJ 5 X x 198 Dimension W x D x H () AHUR6-DAVJ/DABVJ 115 X 155 x 93 AHUR8-DAVJ/DABVJ 15 X 155 x 93 AHUR1-DAVJ/DABVJ 15 X 155 x 93 AHUR16-DAVJ/DABVJ 15 X 165 x 13 AHUR-DAVJ/DABVJ 15 X 165 x 153 AHUR3-DAVJ/DABVJ 195 X 195 x 153 AHUR-DAVJ/DABVJ 195 X 5 x 183 AHUR8-DAVJ/DABVJ 35 X 5 x 183 AHUR6-DAVJ/DABVJ 55 X 5 x 3 Standard Series PCB, expansion Valve and Pre-filter. AHUR-CAVJ/DAVJ/DABVJ SPECIFICATIONS AHUR6CAVJ/DAVJ/DABVJ AHUR8CAVJ/DAVJ/DABVJ AHUR1CAVJ/DAVJ/DABVJ AHUR16CAVJ/DAVJ/DABVJ AHURCAVJ/DAVJ/DABVJ *1 Net Total Sensible Cooling Capacity Total Sensible Cooling Capacity * Gross Total Heating Capacity *1 Net Total Heating Capacity * Gross Air Flow On Coil (Rated) Cooling cmh/m 3 /min CDB/ CWB 3 / 5 7 / 19 8 / 68 7 / / 78 7 / / / / /19 On Coil (Rated) Heating CDB Coil Type DX.Coil (R1A) φ9.5. Wave surface DX.Coil (R1A) φ9.5. Wave surface DX.Coil (R1A) φ9.5. Wave surface Coil Face Area Coil Face Velocity Air PD. In Coil *3 Air PD. Pre *3 Air Filter Size 1 x x *3 Air Filter Size x x m m/s pcs pcs ESP. Initial Total Static Pressure Fan Type FDA5CM FDA5TM FDA5TM FDA315TM FDA355TM * Fan Motor Pole Power Supply V/Ph/Hz 38-15/3/5(6) 38-15/3/5(6) 38-15/3/5(6)-15/3/5(6) FLA Amp Machine Weight (5 / 5 panel) kg 8 / / 66 8/97 9 / 35 9 / / / / / 3 35/55 Outlet Sound Level Pressure (5 / 5) db(a) 67/6 68/6 69/65 7/68 73/69 6/59 65/6 66/61 68/63 69/6 6/59 66/61 67/6 69/6 7/65 7/68 73/69 7/7 76/7 77/7 69/6 7/65 71/66 73/68 7/69 Standard Series PCB Expansion Valve Dimension (WxDxH) /pcs /pcs m EKEQMCBAV3 / 1pc EKEXV1 / 1pc 1.1 x 1.5 x.9 EKEQMCBAV3 / 1pc EKEXV / 1pc 1. x. x.9 EKEQMCBAV3 / 1pc EKEXV5 / 1pc 1. x 1.5 x.9 EKEQMCBAV3 / 1pc EKEXV / 1pc 1. x 1.6 x 1. EKEQMCBAV3 / 1pc EKEXV5 / 1pc 1. x 1.6 x 1.5 nel Type Piping Connections Liq. pipe Gas pipe Drain pipe Ø9.5 (Brazing Connection) Ø19.1 (Brazing Connection) Ø9.5 (Brazing Connection) Ø19.1 (Brazing Connection) Ø9.5 (Brazing Connection) Ø. (Brazing Connection) Ø1.7 (Brazing Connection) Ø8.6 (Brazing Connection) Ø15.9 (Brazing Connection) Ø8.6 (Brazing Connection) Refrigerant Control Capacity Index *1 Net Total Sensible Cooling Capacity * Gross Total Sensible Cooling Capacity Total Heating Capacity *1 Net Total Heating Capacity * Gross Air Flow cmh/ m 3 /min On Coil (Rated) Cooling CDB/ CWB On Coil (Rated) Heating CDB Notes: *1. Net capacity includes indoor fan heat *. Gross capacity does not include indoor fan heat *3. With pre filter, synthetic R9 class G3 (washable) *. Motor is induction motor class F, IP55 5. Table suitable of VRV AHU in Heat pump operation. AHUR3CAVJ/DAVJ/DABVJ / 7 7 /19 AHURCAVJ/DAVJ/DABVJ AHUR8CAVJ/DAVJ/DABVJ / 31 8 / 8 7 / 19 7 / 19 Connection ratio (Heating & Cooling): Coil Type DX.Coil (R1A) φ9.5. Wave surface DX.Coil (R1A) φ 9.5. Wave surface DX.Coil (R1A) φ9.5. Wave surface Coil Face Area Coil Face Velocity Air PD. In Coil *3 Air PD. Pre *3 Air Filter Size 1 x x *3 Air Filter Size x x m m/s pcs pcs ESP. Initial Total Static Pressure Fan Type FDA5TM FDA5TM FDA63TM FDA63TM * Fan Motor Pole Power Supply FLA V/Ph/Hz Amp /3/5(6) /3/5(6) /3/5(6) Machine Weight (5 / 5 panel) kg 69 / / / / / / 1195 Outlet Sound Level Pressure (5 / 5) db(a) 71/67 7/68 73/69 75/7 76/71 7/67 7/68 73/69 75/7 76/71 71/66 7/67 73/68 75/7 77/7 7/67 7/68 73/69 75/7 76/7 Standard Series PCB Expansion Valve Dimension (WxDxH) /pcs /pcs m EKEQMCBAV3 / pcs EKEXV / pcs 1.9 x 1.9 x 1.5 EKEQMCBAV3 / pcs EKEXV5 / pcs 1.9 x. x 1.8 EKEQMCBAV3 / 3pcs EKEXV / 3pcs.3 x. x 1.8 EKEQMCBAV3 / 3pcs EKEXV5 / 3pcs.5 x. x. nel Type Piping Connections Liq. pipe Gas pipe Drain pipe Ø1.7 (Brazing Connection) x Ø8.6 (Brazing Connection) x Ø15.9 (Brazing Connection) x Ø8.6 (Brazing Connection) x Ø1.7 (Brazing Connection) x3 Ø8.6 (Brazing Connection) x3 Ø15.9(Brazing Connection) x3 Ø8.6 (Brazing Connection) x3 Refrigerant Control Capacity Index % 9-11% AHUR6CAVJ/DAVJ/DABVJ % (Cooling) 5-11% (Heating) / 68 7 /19-6% 9-11%

7 Outdoor Air Series AHUR-CALJ/DALJ/DABLJ Outdoor Air Series AHUR-CALJ/DALJ/DABLJ Outdoor Air Series Precise air temperature control via MicroTech III controller. Daikin Outdoor Air Series PCB AHUR CALJ/DALJ/DABLJ outdoor air series are using DX coil. Each DX coil will be connected to one external expansion valve (EKEXV) and controlled by one Outdoor Air Series PCB (EKEQFCBA). 8 5,6 6,1 8,16 1,95 1, 16,38 This reference voltage is used as the main input valve for capacity control through automatic adjustment of Te (Cooling) or Tc (Heating). VRV AHU Expansion Valve (EKEXV) Type AHU Expansion Valve - EKEXV for 8HP Coil - EKEXV5 for 1HP Coil - EKEXV for 16HP Coil - EKEXV5 for HP Coil VRV AHU Outdoor Air Series PCB (EKEQFCBA),8,,3 Micro -Tech III Daikin Outdoor Air Series PCB EKEQFCBA,, 6, 8, 1, 1, 1, 16, 18, Installation of AHU Outdoor Air Series PCB should be positioned under a shaded area. Alternatively, a panel should be provided at the Outdoor Air Series PCB to block off direct sunlight. Direct sunlight will increase the temperature inside the Outdoor Air Series PCB and may reduce its lifetime and influence its operation. Operating temperature of the Outdoor Air Series PCB is between -1ºC and ºC. Outdoor Air Series PCB / VRV AHU AHUR CALJ/DALJ/DABLJ operation is similiar as other VRV indoor unit. Following table is the list of operation range limit for AHU unit. Ambient Temperature Cooling Heating 19ºC DB -5ºC DB VRV IV 3ºC DB -5ºC DB 9ºC DB 15ºC DB -ºC WB 15.5ºC WB Outdoor Air Series PCB -1ºC WB ºC DB

8 Outdoor Air Series AHUR-CALJ/DALJ/DABLJ Outdoor Air Series AHUR-CALJ/DALJ/DABLJ Microtech III MODEL NAME: 1 CASING Metal Insulation CASING FRAME 3 COIL Tube Fin Header Frame Working Pressure FAN Type Wheel Housing Frame 5 MOTOR 6 VIBRATION ISOLATOR 7 DRAIN PAN 8 AIR FILTER Pre Filter Size 9 WEATHER PROOF ROOF 1 OUTDOOR AIR SERIES PCB 11 EXPANSION VALVE AHUR_CALJ / AHUR_DALJ / AHUR_DABLJ AHUR_CALJ : 5 Thickness Double Skinned nel AHUR_DALJ : 5 Thickness Double Skinned nel AHUR_DABLJ : 5 Thickness Double Skinned nel (Thermal Break).5 Thickness White Color Bond Galvanized Steel Sheet 5 / 5 Thickness Polyurethane Foam kg/m 3 Density Aluminum Profile Frame (5 and 5) / Aluminium Profile Frame with Nylon (5 thermal break) DX Coil Copper Tube Aluminum Copper Tube Connect Galvanized Steel 1 kg/cm G or below Double Inlet Centrifugal Belt Driven Fan Galvanized Steel Sheet Galvanized Steel Sheet Galvanized Angular Bars Three-Phase Induction Motor Totally Enclosed Fan-Cooled Type Protection = IP55, Insulation Class = F, efficiency: IE3 For fan size 355 and below, rubber mounting For fan size and above, spring isolator 1. Stainless Steel 3, external cover with 1 PE foam Type = R9, Class = G3, Synthetic washable x x, 1 x x Epoxy Powder Coated Steel EKEQFCBAV3 & Motor Starter nel EKEXV, EKEXV5, EKEXV, EKEXV5 Microtech III Microtech III Drawings and Dimension of AHU Dimension W x D x H () AHUR8-CALJ 11 X x 88 AHUR1-CALJ 1 X x 88 AHUR16-CALJ 1 X 19 x 118 AHUR-CALJ 17 X 19 x 118 AHUR-CALJ 17 X 8 x 118 AHUR3-CALJ 19 X x 18 AHUR-CALJ 19 X x 178 AHUR8-CALJ 19 X x 178 AHUR6-CALJ 3 X x 198 Dimension W x D x H () AHUR8-DALJ/DABLJ 115 X 5 x 93 AHUR1-DALJ/DABLJ 15 X 5 x 93 AHUR16-DALJ/DABLJ 15 X 195 x 13 AHUR-DALJ/DABLJ 175 X 195 x 13 AHUR-DALJ/DABLJ 175 X 85 x 13 AHUR3-DALJ/DABLJ 195 X 5 x 153 AHUR-DALJ/DABLJ 195 X 5 x 183 AHUR8-DALJ/DABLJ 195 X 5 x 183 AHUR6-DALJ/DABLJ 35 X 5 x 3 Outdoor Air Series PCB, expansion Valve and Pre-filter.

9 Outdoor Air Series AHUR-CALJ/DALJ/DABLJ Technical Information AHUR-CALJ/DALJ/DABLJ AHUR8CALJ/DALJ/DABLJ AHUR1CALJ/DALJ/DABLJ *1 Net Total Sensible Cooling Capacity * Gross Total Sensible Cooling Capacity Total Heating Capacity *1 Net Total Heating Capacity * Gross 17.. Air Flow cmh/ m 3 /min / 3 3 / 39 On Coil (Rated) Cooling CDB/ CWB 33 / 8 33 / 8 AHUR16CALJ/DALJ/DABLJ AHURCALJ/DALJ/DABLJ / / / 8 33 / 8 AHURCALJ/DALJ/DABLJ / 1 33 / 8 VRV AHU Standard Series Schematic Diagram Schematic Diagram of Standard Series to Show Line of Responsibility of Daikin & External Installer On Coil (Rated) Heating CDB Coil Type DX.Coil (R1A) φ9.5. Wave surface Coil Face Area m.1.56 Coil Face Velocity m/s Air PD. In Coil 31 *3 Air PD. Pre *3 Air Filter Size 1 x x pcs 1 *3 Air Filter Size x x pcs 1 ESP. Initial Total Static Pressure Fan Type FDA18CM FDA18CM DX.Coil (R1A) φ9.5. Wave surface DX.Coil (R1A) φ9.5. Wave surface FDA5TM FDA5TM FDA8TM * Fan Motor Pole Power Supply V/Ph/Hz 38-15/3/5(6) 38-15/3/5(6) 38-15/3/5(6) FLA Amp Machine Weight (5 / 5 panel) kg 8/98 85 / 33 87/35 3 / 31 36/ / / / 53 3 / / / 561 Outlet Sound Level Pressure (5 / 5) db(a) 6/59 65/6 66/61 68/63 69/6 65/6 66/61 67/6 68/6 69/65 61/56 63/58 6/59 67/6 68/63 63/58 6/59 65/6 67/6 67/63 6/6 65/6 65/61 67/63 68/63 Outdoor Air Series PCB /pcs EKEQFCBAV3 / 1pc EKEQFCBAV3 / 1pc EKEQFCBAV3 / 1pc EKEQFCBAV3 / 1pc EKEQFCBAV3 / 3pc Expansion Valve /pcs EKEXV / 1pc EKEXV5 / 1pc EKEXV / 1pc EKEXV5 / 1pc EKEXV / 3pc Dimension (WxDxH) m 1.1 x. x.9 1. x. x.9 1. x 1.9 x x 1.9 x X.8 X 1. nel Type Liq. pipe Ø9.5 (Brazing Connection) Ø9.5 (Brazing Connection) Ø1.7 (Brazing Connection) Ø15.9 (Brazing Connection) Ø9.5 (Brazing Connection) Piping Connections Gas pipe Ø19.1 (Brazing Connection) Ø. (Brazing Connection) Ø8.6 (Brazing Connection) Ø8.6 (Brazing Connection) Ø19.1 (Brazing Connection) Drain pipe Refrigerant Control Capacity Index *1 Net Total Sensible Cooling Capacity * Gross Total Sensible Cooling Capacity Total Heating Capacity *1 Net Total Heating Capacity * Gross Air Flow cmh/ m 3 /min On Coil (Rated) Cooling CDB/ CWB AHUR3CALJ/DALJ/DABLJ / / 8 AHURCALJ/DALJ/DABLJ AHUR8CALJ/DALJ/DABLJ / 18 1 / 33 / 8 33 / 8 AHUR6CALJ/DALJ/DABLJ / / 8 VRV AHU Standard Series Wiring Diagram (AHUR6CAVJ/DAVJ/DABVJ) On Coil (Rated) Heating CDB Coil Type Coil Face Area m Coil Face Velocity Air PD. In Coil *3 Air PD. Pre *3 Air Filter Size 1 x x pcs *3 Air Filter Size x x pcs ESP. Initial Total Static Pressure Fan Type * Fan Motor Power Supply FLA Machine Weight (5 / 5 panel) Outlet Sound Level Pressure (5 / 5) Outdoor Air Series PCB Expansion Valve Dimension (WxDxH) nel Type Piping Connections Refrigerant Control Capacity Index Liq. pipe Gas pipe Drain pipe m/s Pole V/Ph/Hz Amp. kg db(a) /pcs /pcs m DX.Coil (R1A) φ9.5. Wave surface FDA315TM 3 15/3/5(6) / / 585 EKEQFCBAV3 / pc EKEXV / pc 1.7 x. x 1.5 Ø1.7 (Brazing Connection) Ø8.6 (Brazing Connection) 8 DX.Coil (R1A) φ9.5. Wave surface /79 FDATM FDATM /3/5(6) / /78 77 / / 83 EKEQFCBAV3 / pc EKEXV5 / pc EKEQFCBAV3 / 3pc EKEXV / 3pc 1.9 x. x x. x 1.8 Ø15.9 (Brazing Connection) Ø1.7 (Brazing Connection) Ø8.6 (Brazing Connection) Ø8.6 (Brazing Connection) 1 1 DX.Coil (R1A) φ9.5. Wave surface FDA5TM /3/5(6) / / 16 7/66 71/67 7/68 7/69 7/7 7/66 7/66 71/67 73/68 7/69 71/66 71/67 7/67 73/68 73/69 69/65 7/66 71/67 73/68 73/69 EKEQFCBAV3 / 3pcs EKEXV5 / 3pcs.3 x. x. Ø15.9 (Brazing Connection) x3 Ø8.6 (Brazing Connection) x3 Notes: Connection ratio (Heating & Cooling): *1. Net capacity includes indoor fan heat System ttern Total CR VRV indoor AHU *. Gross capacity does not include indoor fan heat *3. With pre filter, synthetic R9 class G3 (washable) *. Motor is induction motor class F, IP55 5. Air Temperature control via Microtech III Controller 6. Table suitable for VRV AHU in Heat pump operation 7. Above Net capacities are based on the conditions below: Discharge temperature: 19 CDB (Cooling), 5 CDB (Heating) Rated condition (On Coil): 33 CDB/8 CWB (Cooling), CDB (Heating) Only AHU (ir AHU & Multi AHU) 9-11% % Note: Discharge temperature for AHUR16, & 6 is expected to be higher than 19 CDB, refer to engineering data book for further details 15

10 Technical Information Technical Information VRV AHU Series AHUR xx CAVJY1/ DAVJY1/ DABVJY1 ( Standard, 38-15V/ 3Ø/ 5Hz ) AHUR xx CALJY1/ DALJY1/ DABLJY1 ( OA, 38-15V/ 3Ø/ 5Hz ) VRV AHU HP Standard Series Outdoor Air Series Field Pipe Daikin Supplied Connection by Daikin Daikin Supplied Field Pipe X A B C D Y

11 Specifications, designs and other content appearing in this brochure are current as of March 16 but subject to change without notice. c All rights reserved

PCXDMT1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

PCXDMT1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A PCXDMT1601 VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ Heat Pump 50/60 Hz R-10A Airport Lobby Hospital Factory Shopping Mall Sports Hall Showroom Warehouse

More information

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM an ELTA GROUP company ELTAFANTECH 700 up to 42,000 CFM INNOVATIVE Design & Performance INTRODUCTION There are 24 standard sizes of optimally engineered s to handle air volumes from 700 CFM to 42,000CFM.

More information

The World Leading Air-conditioning Company

The World Leading Air-conditioning Company The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040

More information

Prepared By : Checked By : Approved By : Page 1 out of 6

Prepared By : Checked By : Approved By : Page 1 out of 6 Software Name Carrier AHU - Version 1.0, Patch R1.1X UNIT MODEL GENERAL SPECIFICATIONS GENERAL LOCATION / WEIGHT UNIT DIMENSION Configuration : Quick Selection Wizard Unit Orientation : Horizontal Box

More information

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements AIR HANDLING UNITS Customisable modular air handling unit, designed and built to suit your project requirements PacAir Modular Air Handling Units by are customisable, designed and built for n, New Zealand

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

AIR HANDLING UNIT. MODEL: PM0809 to PM CFM to CFM

AIR HANDLING UNIT. MODEL: PM0809 to PM CFM to CFM AIR HANDLING UNIT MODEL: PM0809 to PM2738 700CFM to 41000 CFM POWER METAL TECHNOLOGIES (M) SDN BHD Lot 37830, Jalan Bukit Naga, Kampung Bukit Naga, Section 32, 40460 Shah Alam, Selangor Darul Ehsan. Tel:

More information

Commercial Blower Coil Air Handlers

Commercial Blower Coil Air Handlers Commercial Blower Coil Air Handlers MODEL : BDH(V)B - 048, 065, 080 7400 CMH - 14300 CMH 30 kw - 125 kw BCXB-PRC001-E4 Contents Model Number Description General Specification Standard Features Unit Configuration

More information

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

1 AIR HANDLING UNIT TYPE AIR ACCESS 75 SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting

More information

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option 42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw) -P Series 50Hz Rooftop Units Cooling Capacity : to 388 MBH (8 to 407 kw) Heating Capacity : 8 to 98 MBH (8 to 380 kw) 40A Products that perform...by people who care NOMENCLATURE AC P S E 435 P HP G Q Air

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11 AIR HANDLING UNIT (DOUBLE SKIN) MODEL: DS-CW/DX-AHU-H (Chilled Water or Direct Expansion) CAPACITY: 3.3 to 125 Nominal Tons 39,000 to 1,500,000 BtuH 11.4 to 439.5 KW 1,300 to 50,000 CFM Benefits Horizontal

More information

CHILLED WATER FAN-COIL UNITS

CHILLED WATER FAN-COIL UNITS 40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in

More information

Midea Air Handling Unit

Midea Air Handling Unit Midea Air Handling Unit Floor mounted 3000CFM ---25000CFM Vertical mounted 3000CFM ---25000CFM Ceiling suspended 1000CFM ---9000CFM Midea reserves the right to improve the product and technology without

More information

MODULAR AIR HANDLING UNITS GAH SERIES

MODULAR AIR HANDLING UNITS GAH SERIES MODULAR AIR HANDLING UNITS GAH SERIES 15 Models with Air Flows from 2,250 Cu.m/hr upto 77,800 Cu.m/hr Suitable for both Standard and District Cooling Applications GAH-TC-10-13 CONTENTS Design 2 Various

More information

CHILLED WATER DUCTED FAN COIL

CHILLED WATER DUCTED FAN COIL SD CHILLED WATER DUCTED AN A Series B Series (Double Skin) General abricated with a rigid galvanized steel casing. The DIDW centrifugal fans have balanced, galvanized steel, and forward curved blades.

More information

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS DECORATIVE FAN COIL SPECIFICATIONS UNIT CABINET Single skin or double skin casing (inner perforated sheet or flat sheet) made of powder coated galvanized steel assembled in aluminum extrusion profiles,

More information

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal

More information

And ASEAN EAW WATER) Head. Office : Ruko

And ASEAN EAW WATER) Head. Office : Ruko The Winner of INDONESIA ENERGY AWARD 2013 And ASEAN ENERGY AWARD 2004 2012 AIR HANDLING UNIT (AHU CHILLED WATER) 1.600 M³/ /hr. 52.000 M³/hr EAW CHILLED WATER PT. METROPOLITAN BAYU INDUSTRI A member of

More information

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor SUBMITTAL DATA for Prepared by Kevyn Gordon 4/27/2017 Job Name: 1 of 35 www.daikinapplied.com Table of Contents Technical Data Sheet for AHU-1st Floor... 3 Fan Curve for AHU-1st Floor... 7 Drawing for

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

Engineering Data Book

Engineering Data Book 40VMH High Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

Engineering Data Book

Engineering Data Book 40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP VEP075N432K Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Hinged electrical box for ease of maintenance

More information

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series Inverter cooling only / heat pump series RSX(Y)P5,8,10K7W1 RSX(Y)P-K7W1 1 Inverter cooling only / heat pump series 1 1 Specifications

More information

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1

More information

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9 ALDI # CITY, STATE SUPERMARKET MultiPath RTUTYPE 9 (RTU1) CESMPU025REVAV9 Date: December 1, 2014 2013 Consolidated Energy Solutions, Inc. UNIT FEATURES CES TYPE VAV9 Unit features include: 25 ton MultiPath

More information

VAHU Vertical Air Handling Unit

VAHU Vertical Air Handling Unit 500 to 5,400 CFM @ up to 6.00" TSP 2" double wall construction, perforated or solid lined 18 gauge G90 galvanized steel cabinet 4 standard cabinet sizes available Internally isolated direct drive plug

More information

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series. Chilled Water FCU A Series 3-25 CFM Horizontal Fan Coil 5hz www.windind.com CONTENTS GENERAL CONSTRUCTION... 3 MODEL NUMBER NOMENCLA TURE... 4 DIMENSIONS... 5 FAN PERFORMANCE DATA... 7 GENERAL SPECIFICATIONS...

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

Low Static Pressure Duct(V shape evaporator)

Low Static Pressure Duct(V shape evaporator) Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...

More information

Air Cooled Packaged Units

Air Cooled Packaged Units Air Cooled Packaged Units Technical Data OPA 465, OPA 550, OPA 705, OPA 855, OPA 960 (ECO) Cooling Capacity 44.9kW - 96.0kW Heating Capacity 41.1kW - 90.0kW Contents OPA 465 960 ECO 3 General 3 Applications

More information

Water Source Heat Pump P 34 P 35. Features. Optional. Instruction of model. Water-Cooled Screw Chiller

Water Source Heat Pump P 34 P 35. Features. Optional. Instruction of model. Water-Cooled Screw Chiller Source Heat Pump -Cooled Screw Chiller R410a Product type LSSR10 LSSR14 LSSR16 LSSR20 LSSR28 Rated cooling capacity kw/btu/h 10.5 35836.5 14 47782 15.5 52902 21 71673 28 95564 Rated heating capacity kw/btu/h

More information

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................

More information

ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz

ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz Condensing Models TTK 060 KD TTA 075 RD TTA 100 RD TTA 120 RD TTA 150 RD TTA 180 RD TTA 200 RD TTA 240 RD Air

More information

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump)

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) PRK 00-04 PREVIEW System OZONE FRIENDLY R-407C Series Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) 3DUW#4 2XWGRRU#8QLWV 111111111111111111111111111111111111111111111111111111111111111111111

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information

Landmark Rooftop Packaged Units

Landmark Rooftop Packaged Units Landmark Rooftop Packaged Units Engineered for superior performance and reliability Exclusively distributed by AUS - 13 23 50 www.lennoxaus.com.au NZ - 0800 653 330 www.lennoxnz.co.nz 1 Landmark Rooftop

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

Concealed Ducted Split Series R22

Concealed Ducted Split Series R22 Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING

More information

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications

More information

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E R407C TECHNICAL MANUAL Split Systems Air Conditioner Ducted Blower D & E Series FDMP-D, FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E series Cooling only & Heatpump [50Hz] Table of Contents Table of Contents

More information

DOUBLE SKIN MODULAR AIR HANDLING UNIT. Round Edge (ADM-AHU)

DOUBLE SKIN MODULAR AIR HANDLING UNIT. Round Edge (ADM-AHU) DOUBLE SKIN MODULAR AIR HANDLING UNIT Round Edge (ADM-AHU) AIR HANDLING UNIT Acson Double Skin Modular Air Handling Unit is designed based on a modular concept, making it suitable for breaking down into

More information

INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter

INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter INTRODUCTION GENERL DESCRIPTION Ducted Direct Drive Fan Coil ir Conditioners are designed to fulfill the air conditioning requirements of today s living. These requirements include dependable trouble-free

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

Low Static Pressure Duct (V shape evaporator)

Low Static Pressure Duct (V shape evaporator) MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...

More information

WATER SOURCE HEAT PUMPS

WATER SOURCE HEAT PUMPS HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

BELT DRIVEN CABINET FANS CVTT Series

BELT DRIVEN CABINET FANS CVTT Series Range of forward curved belt drive cabinet fans manufactured from galvanised steel sheet, internally lined with melamine thermo-acoustic insulation. ll models incorporate a double inlet low pressure centrifugal

More information

CS3 Series 50/60Hz. Modular Central Station Air Handling Units Air Volume: 1000 to cfm (1700 to m 3/hr)

CS3 Series 50/60Hz. Modular Central Station Air Handling Units Air Volume: 1000 to cfm (1700 to m 3/hr) CS3 Series 50/60z Modular Central Station Air andling Units Air Volume: 1000 to 56000 cfm (1700 to 90 m 3/hr) Products that perform...by people who care DUNAM-BUS CS3 Series Introduction For more than

More information

Engineering Data Book

Engineering Data Book 40VMM Medium Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with

More information

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4

More information

Package Air Conditioners

Package Air Conditioners MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment

More information

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT 50JZ (50Hz.)-C1SB 50JZ 7 to 14 kw (024-048) STANDARD EFFICIENCY SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB

More information

Address: VTS Clima L.L.C.

Address: VTS Clima L.L.C. Address: VTS Clima L.L.C. Business Bay, Churchill Tower, Office 2409, P.O.Box#76849 Dubai, UAE phone: +971 (4) 443 91 20 fax: +971 (4) 443 96 20 e-mail: dubai@vtsgroup.com www.uae.vtsgroup.com Index VTS

More information

Technical Service Manual

Technical Service Manual Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2013.12 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................

More information

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series Cabinet fans manufactured from galvanised steel sheet with double thickness side panels lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connection flange on the

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8

More information

DUNHAM-BUSH ecs3 Series

DUNHAM-BUSH ecs3 Series DUNAM-BUS ecs3 Series INTRODUCTION For more than 100 years, Dunham-Bush has focused on innovative product development. Today, we provide a full portfolio of VAC/R products from Coil Units to large centrifugal

More information

McQuay MDM Air Handling Unit CMDM

McQuay MDM Air Handling Unit CMDM McQuay MDM Air Handling Unit CMDM - 2004 Contents Page Nomenclature System... 1 Features... 2 Performance Tables... 4 Outlines and Dimensions... 15 Section Weights... 23 Installation... 25 Operation...

More information

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low

More information

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016 Modular Air Handling U n i t R a n g e Up to 3,500 Litres / sec Low profile & Plant room application AirDesign 2015 AirDesign 2016 Second Edition Draft Version A-. Air Design is a proud Australian based

More information

Project Name: Brooks Landing Banquet Center

Project Name: Brooks Landing Banquet Center Tag: RTU-1 Comments: Unit Information Cooling Performance Heating Performance Model: Horizon (B/G) Unit Length: 208 in Size: G120 Unit Width: 74 in Quantity: 1 Unit Height: 67 in Supply Airflow: 4,000

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

Compact Four-way Cassette Type

Compact Four-way Cassette Type 1. Features... 34 2. Specifications... 35 3. Dimensions... 37 4. Service Spaces... 38 5. Piping Diagrams (EXV beside)... 39 6. Wiring Diagrams... 40 7. Capacity Tables... 41 8. Electrical Characteristics...

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105 TECHNICAL CATALOGUE WPHA Cooling only WPHBA Heat pump Models 091, 121, 141, 171, 201, 251, 351, 401, 501, 701, 751, 1001, 1201 Cooling capacities from 2,4 kw to 41 kw Heating capacities from 2,8 kw to

More information

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application 42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT MODEL NUMBER NOMENCLATURE 4 2 C E T 0 0 3 4 7 0 1 2 5 42 series CISB Code

More information

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

A Division of Nailor International Inc. ECONOMY AIR HANDLERS A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical

More information

Nomenclature. Contents. Air Handling Unit SR AH 250 LP HS

Nomenclature. Contents. Air Handling Unit SR AH 250 LP HS SARAN Mf g. Group 1 Contents Features...... 2-4 Selection Procedures... 5-7 Capacity Ratings (Chilled Water, D.X Coil, Hot Water, Steam Ratings)... 8-15 Correction Factor Tables... 16-18 Dimensions (Horizontal

More information

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average

More information

DXP 100. Dry Cooler CERTIFY-ALL DX COOLERS

DXP 100. Dry Cooler CERTIFY-ALL DX COOLERS Dry Cooler CERTIFY-ALL DX COOLERS PRESENTATION The coolers are designed for outdoor applications. All technical data are based on different mixtures of cooling media i.e.ethylene glycol mixture. The coolers

More information

MAH. Modular Air Handling Unit

MAH. Modular Air Handling Unit MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

Service manual MIV V4+ Indoor units

Service manual MIV V4+ Indoor units Service manual MIV V4+ Indoor units Floor Standing MVF22A-VA1 MVF28A-VA1 MVF36A-VA1 MV5A-VA1 MVF56A-VA1 MVF71A-VA1 MVF80A-VA1 MVB22A-VA1 MVB28A-VA1 MVB36A-VA1 MVB45A-VA1 MVB56A-VA1 MVB71A-VA1 MVB80A-VA1

More information

technical catalogue tetris KW Chiller and heat pumps air/water

technical catalogue tetris KW Chiller and heat pumps air/water technical catalogue tetris 110 930 KW Chiller and heat pumps air/water > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

Air Conditioners. Technical Data UATYQ-CY1

Air Conditioners. Technical Data UATYQ-CY1 Air Conditioners Technical Data R o o f t o p s E E D E N 2-2 0 UATYQ-CY Air Conditioners Technical Data R o o f t o p s E E D E N 2-2 0 UATYQ-CY Single Unit Rooftop UATYQ-CY TABLE OF CONTENTS UATYQ-CY

More information

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers

More information

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH TEMPERATURE TWIN SQUIF FANS HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing

More information