1 Polyester Insulating Enclosures Thalassa PLS, PLM & PLA Boxes, wall-mounting and floor-standing enclosures Catalogue 0 For outdoor and harsh environment electrical distribution, automation, signalization and IT applications

2 Insulating enclosures Thalassa PLS Insulating modular boxes 9 Selection guide 0 Dimensions PB5006 PB PB5005 PB505 PB PB500 Thalassa PLM Wall-mounting in polyester 0 Dimensions 5 Selection guide 6 Thalassa PLA Floor-standing in polyester PLA version: Completely sealed enclosure PLAT version: Ventilated canopy 5 PLAZ version: Plinth-type open bottom 6 PLAZT version: Plinth-type open bottom and ventilated canopy 7 Dimensions 8 Accessories 50

3 Thalassa Polyester enclosures Installation examples Schneider Electric enclosures made from insulating materials are designed to protect your equipment in harsh environments or in contact with the public: Infrastructures: protection against bad weather (solar radiation, rain, etc.), impacts, saline atmospheres, etc. Transport: resistance to UV, salt mist, tightness and impact resistance, etc. Water: resistance to corrosion, resistance to impact and UV, resistance to chemical substances, etc. Outdoor telecom and networks: resistance to UV, resistance to corrosion, protection of 9-inch accessories, etc. Power: resistance to impact, to salt mist, etc. Public lighting: anti-vandalism, anti-posting, UV resistance, etc. Industries in aggressive environments: resistance to corrosion, to chemical substances and protection against electrical hazards. PB5075 PB507 PB507 Outdoor installation, with exposure to atmospheric conditions: mist, solar radiation, extreme temperatures, etc. Self-ventilated enclosure with anti-posting doors and canopy. Indoor or outdoor installation on industrial zones in aggressive environments.

4 Thalassa PLS - PLM - PLA Polyester enclosures Our solutions Thalassa PLS boxes A range of insulating modular boxes for creating assemblies that separate functions and provide easy visibility thanks to their transparent covers. box sizes from mm to mm. Accessories for power, automatism and modular applications. PB5076 PB500 Thalassa PLM wall-mounting enclosures ABS/PC or polyester monobloc enclosure, IP 66, plain and transparent doors with built-in top and bottom canopies allowing the enclosures to be inverted. 8 sizes from mm to mm. Large range of accessories (common with the Spacial D universal enclosure) for power, automatism and modular applications.

5 Thalassa PLS - PLM - PLA Polyester enclosures PB5077 Thalassa PLA floor-standing enclosure Modular design, made from polyester, combining: 0 sizes. versions available, from completely sealed (IP 65) to self-ventilated with canopy and/or open bottom (IP or 5). Plain, glazed or anti-posting door. The large range of accessories allows it to adapt to all your needs: Power distribution. Automatism. Modular. 9".

6 Thalassa PLS - PLM - PLA Polyester enclosures Customised solutions Configured Specific The customised offer anticipates the adaptation needs of the standard offer Advantages of our customised offer Preparation for installation with machining Save time on marking out and transport to the machining location, avoid drilling errors with pre-machining of the body, panels and doors. PB508 PB5085 PB508 PB508 PB508 PB5080 Save time with pre-installed accessories On the polyester floor-standing and wall-mounting enclosures, we can supply or rapidly install a selection of accessories. Save time with machined accessories In order to adapt better to your needs, we can machine the accessories for polyester wall-mounting and floor-standing enclosures, including mounting plate, internal doors, cable-gland plates, etc. Improve its appearance with colour For better integration of your enclosures in their environment or to help identify them, we offer you two solutions: Enclosures with colour in the mass, maintenance free (minimum amount required). Repainting of standard enclosures. Application of anti-graffiti paint. Increase the service life of your equipment Installation of the most frequent accessories of the thermal range in the factory. 5

7 Thalassa PLS - PLM - PLA Polyester enclosures Installation examples Configured Specific Machined, coupled and equipped Thalassa PLS boxes PB5089 PB5088 PB5087 PB5086 Thalassa PLM wall-mounting enclosure machined in the factory to accommodate cable glands Thalassa PLA floor-standing enclosure with accessories installed in the factory Coupled Thalassa PLA floor-standing enclosures with accessories installed ain the factory 6

8 Thalassa Polyester enclosures Definition help Specific Checklist to help define a specific need You can not find the solution you are looking for in our general catalogue or in the configured offer? Then you need our specific offer. To optimise your special solution, we will study all the aspects of your project in the checklist below. PB50050 Project profile Quantity of enclosures Repetitive request (yes/no) Rates (number, frequency, amount per rate)? Environment Internal or external use? Type of environment: normal, saline, corrosive (what products?) Usage constraints (vibrations, etc.). Technical definition Product description (drawing, technical specifications) Dimensions, assemblies Required IP, IK Colour, anti-graffiti, anti-posting Loads to withstand: by the enclosure, by the doors and panels Cable entry (top, bottom, etc.), IP Glazed door, window, etc. Type of lock Definitions of machining operations (drawings, etc.) Electrical continuity by earthing braids or others (to be specified) Accessories Standard accessories installed Specific accessories to be supplied (plans, drawings, etc.), to be installed Other Possible reference norms Classification tests to be planned (for the internal classification plan) mechanical strength, electrical continuity, etc. Packaging Is standard packaging sufficient? If not, what type of packaging is required? Packaging labels (amount, position, type of information)? Palletisation constraints? 7

9 Thalassa Polyester enclosures Customised solutions Specific Choice For the accessory options, specify whether you want supply or installation General options of the basic enclosure Quantity Dimensions H (mm) W (mm) D (mm) Versions Choice of fixing or base accessories Fixing lugs, type Plinths, type and size Post-fixing device, post type Seats, special structures, etc. Body and cable-accessory options Cable entry: cable-gland plate, type Other solutions (brushes, quick entries, cable-glands, etc.) Cable supporting accessories Other accessories (power, lighting, etc.) Definition of the surfaces and the cut-outs (diagrams, drawings, DXF SE diagrams) Door and door-accessory options Front door, rear door, windows, glazed door Choice of handle/insert Door stop, door contact Document lip, shelves Cable supporting accessories Definition of the cut-outs for windows and switchgear (diagrams, drawings, DXF SE diagrams) Mounting accessory options Metallic mounting plate; plain, microperforated, Telequick, silkscreened Insulating mounting plate (polyester, bakelite) Symmetrical, asymmetrical, mixed uprights With plain or Telequick partial plates 9 chassis Depth adjustment Complementary fixings Internal door Cut-outs of the plates, internal doors (diagrams, drawings, DXF SE diagrams) Thermal Do you need to cool? Heat? Ventilate? Have you calculated a heat balance to dimension your solution? External temperature range Internal temperature range (operation of the device) Dissipated power Choice of ventilation options Ventilation louvres, ventilation grilles Fan Thermostat/Hygrostat Positions, cut-outs (diagrams, drawings, etc.), installed accessories Logistics Delivery location, special storage Specific unloading or delivery mode Resumption of transport after equipping Additional remarks 8

10 Thalassa PLS Insulating modular boxes Modular The dimensions of the sides, multiples of 9 cm, allow the creation of assemblies. Protection IP 65. Gasket between body and cover. Choice sizes. 9 combinations of length width. cover heights. Transparent cover. Opaque cover made from polycarbonate or polyester. Industry or infrastructure Energy, automatism. Accessories for modular distribution. PB5090 Safety Full insulation for class II equipment. Locking with, 6 or 8 points. Customisation Various machining operations of the rear and the cover. Option of colour in the mass. Easy Bosses with inserts, at the rear of the body, for fixing plates or various supports. 9

11 Thalassa PLS IP 65 insulating modular boxes Introduction PB500 The product references show the two lateral dimensions in cm. sizes of insulating boxes; the sides are multiples of 9 cm. Insulating boxes that can be coupled by all their side surfaces, allowing the creation of the greatest variety of modular assemblies. Rear made from polyester reinforced with fibreglass, moulded by hot compression, 9 sizes. types of cover available according to the sizes: Standard cover, made from transparent polycarbonate with neoprene gasket, 5 mm high, or mm high (final index A) according to the sizes. Opaque polycarbonate cover (index C), with neoprene gasket, 5 mm high, or mm high (final index A) according to the sizes. Polyester cover (index P) with PUR gasket, 5 mm high. The rears (prefix F) and the covers (prefix T) are supplied separately as standard references. The separate covers are supplied without locking screws or sealing accessories. The PLS enclosures with transparent cover are also offered in batches; the reference refers to the complete batch. Technical characteristics Degree of protection: IP 65. Resistance to external mechanical impacts: IK 09. RAL 70 grey colour (opaque rears and cover). Excellent resistance to corrosion; can withstand most chemical agents. Full insulation to create class II assemblies. Standard lock with slot screws outside the volume of the boxes. Delivered with sealing system. External wall mounting by lugs, to be ordered separately. Service temperature: 0 to + 0 C. Bosses with M6 inserts for fixing the mounting plate. Halogen-free and compliant with the RoHS directive. Certification according to standard IEC 608, guaranteeing IP, IK, resistance to heat and fire (self-extinguishing), insulation to 5000 V, resistance to bad weather and load of the mounting plate, 00 kg/m. UL certification and NEMA classification X and. Selection guide PB50009 PB5000 PB5000 PB50009 PB50009 Dimensions (mm) Complete box Complete boxes in batches Height Width Depth Transparent cover Opaque cover Polyester cover Transparent cover Amount per batch NSYPLS87 NSYPLSC87 NSYPLSP87 NSYPLS87L NSYPLS77 NSYPLSC77 NSYPLSP77 NSYPLS77L NSYPLS77A NSYPLSC77A NSYPLS77AL NSYPLS76 NSYPLSC76 NSYPLSP76 NSYPLS76L NSYPLS76A NSYPLSC76A - NSYPLS76AL NSYPLS75 NSYPLSC75 NSYPLSP75 NSYPLS75L NSYPLS75A NSYPLSC75A - NSYPLS75AL NSYPLS66 NSYPLSC66 NSYPLSP66 NSYPLS66L NSYPLS65 NSYPLSC65 NSYPLSP65 NSYPLS65L NSYPLS65A NSYPLSC65A - NSYPLS65AL NSYPLS67A NSYPLSC67A - NSYPLS67AL NSYPLS55 NSYPLSC55 NSYPLSP55 NSYPLS55L NSYPLS55A NSYPLSC55A - NSYPLS55AL NSYPLS57A NSYPLSC57A - NSYPLS57AL 0

12 Thalassa PLS IP 65 insulating modular boxes Introduction Selection guide for rears and covers (without screws) PB50007 PB5000 PB5005 PB5000 PB5096 PB509 PB509 PB509 PB509 PB509 PB50 Height Dimensions (mm) Width Rear 5 mm Transparent 5 mm Low covers Opaque 5 mm Polyester 5 mm Transparent mm High covers Opaque mm NSYFPLS87 NSYTPLS87 NSYTPLSC87 NSYTPLSP NSYFPLS77 NSYTPLS77 NSYTPLSC77 NSYTPLSP NSYFPLS NSYTPLS77A NSYTPLSC77A NSYFPLS76 NSYTPLS76 NSYTPLSC76 NSYTPLSP NSYFPLS NSYTPLS76A NSYTPLSC76A NSYFPLS75 NSYTPLS75 NSYTPLSC75 NSYTPLSP NSYFPLS NSYTPLS75A NSYTPLSC75A NSYFPLS66 NSYTPLS66 NSYTPLSC66 NSYTPLSP NSYFPLS65 NSYTPLS65 NSYTPLSC65 NSYTPLSP NSYFPLS NSYTPLS65A NSYTPLSC65A NSYFPLS NSYTPLS67A NSYTPLSC67A NSYFPLS55 NSYTPLS55 NSYTPLSC55 NSYTPLSP NSYFPLS NSYTPLS55A NSYTPLSC55A NSYFPLS NSYTPLS57A NSYTPLSC57A Selection guides for mounting plates For installing in the boxes (mm) Metallic mounting plates Insulating mounting plates Height Width Plain Telequick Polyester Bakelite NSYPMM87 NSYPMR87 NSYPMA87 NSYPMB NSYPMM77 NSYPMR77 NSYPMA77 NSYPMB NSYPMM76 NSYPMR76 NSYPMA76 NSYPMB NSYPMM75 NSYPMR75 NSYPMA75 NSYPMB NSYPMM66 - NSYPMA66 NSYPMB NSYPMM65 NSYPMR65 NSYPMA65 NSYPMB NSYPMM67 NSYPMR67 NSYPMA67 NSYPMB NSYPMM55 NSYPMR55 NSYPMA55 NSYPMB NSYPMM57 NSYPMR57 NSYPMA57 NSYPMB57 Selection guides for modular distribution chassis For installing in the boxes (mm) Modular distribution chassis Height Width Page 7 No. of rows No. of 8 mm modules NSYDLS NSYDLS NSYDLS NSYDLS NSYDLS8 8 Modular distribution application offer: box and chassis, see pages 7 and 8.

13 IP 65 insulating modular boxes Thalassa PLS Dimensions Dimensions (mm) C E B D F * Thickness NSYPLS * * * * * * * A NSYPLS * * * * * * * * NSYPLS NSYPLS NSYPLS DB0060EN NSYPLS NSYPLS *.. 9 * * NSYPLS *.. 9 * * NSYPLS DB0060EN The surfaces are numbered to enable identification of the surfaces to be drilled in the customised offer. of mm for the polyester cover. A Bottom and bottom cover. B Bottom and top cover. C D Internal view of the corners, details of the bosses with M6 inserts. E F Internal view of the corners of the poyester covers with bosses for inserts ref. NSYTEX5 for M5 screws.

14 Thalassa PLS IP 65 insulating modular boxes Accessories Wall-fixing lugs Set of lugs and fixings. Material: passivated zinc-coated or stainless steel. PB5097 Name Steel mounting lugs Stainless-steel mounting lugs References NSYPF7N NSYPF7X PB5098 DB0060 Post-fixing device Contains all the elements required for mounting on a post. For installation on a surface with dimensions (mm) References 70 NSYFSP NSYFSP NSYFSP750 PB5099 PB5000 Coupling frames Coupling frame for an opening of 0 mm (for 80 mm surfaces). Coupling frame for an opening of mm (for 70 mm surfaces). Coupling frame for an opening of 90 mm (for 60 mm surfaces). A sealing gasket is built into the frame with full opening to maintain the protection rating of IP 65. Frame with partial opening: without gasket and IP. Opening (mm) References Full-opening frame Partial-opening frame 0 NSYUM780 - NSYUM770 NSYUCC70 () 90 NSYUM760 NSYUCC60 () () References by unit. Order by multiples of 0 units (0, 0, 0, etc.). Side plates mm cable-gland plate or locking plate for the 70 mm surfaces. 90 mm cable-gland plate or locking plate for the 60 mm surfaces. IP 65 maintained by a sealing gasket. PB500 Side plates (mm) References NSYTL NSYTL760

15 Thalassa PLS IP 65 insulating modular boxes Accessories Box coupling unit piece For coupling, or boxes, with optional wall mounting. To be ordered in multiples of 5. PB500 For coupling References boxes NSYPSC7 or boxes NSYPSC7 DB0060 M6 8 screw with cylindrical head. PB500 Hinges Set of external hinges made from plastic or internal hinges made from brass. To open the door to 80º. Name References External plastic hinges Internal brass hinges NSYBE7 NSYBL7 PB50 PB505 PB500 Insulators for busbar Ref. NSYAE5 for bars of 5 or 0 mm. Utilisation on the 70 mm side. Ref. NSYAS5* for bar of 5, 0 or 0 mm. NSYAE5 NSYAS5 * References by unit. Order by multiples of 5 units (5, 0, 5, etc.). Specific Drill holes The machining operations on the dimensions of the lateral plates or frames can be specifically produced in our factory. The surfaces can be identified by the numbers provided on page. DB00605 Side cut-out press, ref. NSYPUC7. DB00606

16 Thalassa PLS IP 65 insulating modular boxes Accessories PB5005 PB5006 With slotted head With wings With plumbable triangular head PB5007 Closing for PLS boxes Set of, 6 or 8 screws. Three types of screws are available: With slotted head. With wings. With plumbable triangular head. The references also include M6 screws for fixing mounting plates and steel sealing accessories. Name Tool References Set of slotted screws () Flat-blade screwdriver NSYTCD7 Set of 6 slotted screws () Flat-blade screwdriver NSYTCD76 Set of 8 slotted screws () Flat-blade screwdriver NSYTCD78 Set of wing screws () Manual NSYTCM7 Set of 6 wing screws () Manual NSYTCM76 Set of 8 wing screws () Manual NSYTCM78 Set of triangular screws NSYTCT7 Set of 6 triangular screws NSYLT7 NSYTCT76 Set of 8 triangular screws NSYTCT78 () Included in the standard references of boxes NSYPLS. () Included in the standard references of modular distribution boxes NSYPLS DLS. Closing locks Option of installing a side lock, on the opposite side to where the hinges are installed. PB5008 PB5009 Name Tool References Double-bar side lock and handle NSYDBP NSYCL7M Side lock with key 05 NSYCL7L05 Side lock with key E NSYCL7LE Sealing and opening Name References PB500 PB500 PB50 Plastic-coated sealing triangle* Triangular key for PLS NSYPPS7 NSYLT7 * References by unit. Order by multiples of 0 units (0, 0, 0, etc.). Plastic carrying handle Name Carrying handle Reference NSYATM7 DB00607 PB50 M M6 5

17 Thalassa PLS Insulating modular boxes Accessories Examples of assembly NSYPSC7 NSYPLS57DLS8 NSYUCC70 Plate NSYUM770 with cable-gland NSYBE7 All the boxes can be joined by their lateral surfaces, using the coupling frames NSYUM or NSYUCC, and the joining and fixing pieces NSYPSC7 and NSYPSC7. DB00608 PB50 NSYTL770 NSYUM770 NSYTL770 6

18 Thalassa PLS Insulating modular boxes Modular distribution application Insulating modular boxes with modular distribution chassis PLS boxes, polyester rear and PC transparent cover with hinges and wing screws for manual opening. Built-in DLS modular chassis, made up of an insulating protection panel, RAL 70 colour, 5-mm DIN rails and a mm neutral/earth connection strip. Opening for cable entry, delivered with lock plate, ref. NSYTL770. Double-insulating installation. Plastic external hinges, allowing opening to 80º. Removable 6-mm blanking covers ( modules): per row in the standard offer. The modular chassis can be ordered separately, see references page. PB506 NSYPLS57DLS8 The boxes can be equipped with a double-bar lock and handle ref. NSYCL7M, or a lock with key ref. NSYCL7L05, by specific demand. Specific 7

19 Thalassa PLS Insulating modular boxes Modular distribution application Height (A) External dimensions (mm) Width (B) Depth (C) Selection guide Number of 8 mm modules Number of rows Approximate weight (kg) References NSYPLS87DLS NSYPLS77DLS NSYPLS67DLS NSYPLS67DLS NSYPLS57DLS8 Dimensions (mm) NSYPLS87DLS NSYPLS67DLS6 NSYPLS77DLS NSYPLS57DLS8 NSYPLS67DLS DB

20 9

21 Thalassa PLM Polyester wall-mounting enclosures Service life High resistance to corrosion in harsh environments, maintaining its mechanical properties and insulation. Protection IP 66. Polyurethane gasket. Built-in canopy. Lock outside sealed area. Choice ABS/PC dimension and 7 polyester dimensions. Smooth or glazed door. Easy Door easily reversible by turning it over. Opening to 0 or 80. Easy machining with no corrosion. Lightness. Smart Notches for easy fixing of DIN rails. Grid pattern on the rear of the door for marking the machining operations. PB505 Customisation Configured: machining and accessories. Specific: non-standard colour and accessories. Safety Full insulation (to produce class II units). Mechanical strength. No risk to the public. Applications Industry or infrastructures in harsh environments. Indoor or outdoor installation. Accessories for modular distribution. 0

22 Thalassa PLM General characteristics of the Thalassa PLM wall-mounting enclosures: Indoor or outdoor use. size for the ABS/PC wall-mounting enclosure ( mm). 7 sizes of polyester wall-mounting enclosures. Monobloc body including the canopies (gasket protection), except for wall-mounting enclosure ref. NSYPLM05. Doors with polyurethane gasket. types of doors. Smooth. Transparent (for the ABS/PC enclosure) or glazed (for the polyester enclosures). Reversible door opening direction by turning the enclosure over. Degree of protection IP 66 according to standard IEC Impact resistance IK 0 for the plain doors and surfaces and IK 08 for the glazed doors of the polyester versions, according to standard IEC 66. Many accessories in common with the range of steel wall-mounting enclosures, Spacial SD or Spacial CRN. Certificate of conformity with enclosure standard IEC 608 for: IP, IK, resistance to heat and fire, insulation 5000 V, resistance to bad weather and corrosion and resistance to internal loads (50 kg/m ) and loads on the door (0 kg/m ). UL certification and NEMA classification x and for the polyester wall-mounting enclosures Total insulation to produce class II units according to IEC 69- Complies with RoHS and REACH Directives Properties of the material of the polyester versions The wall-mounting enclosures are made from polyester reinforced with fibreglass, moulded by hot compression, RAL 70 colour. This material: Is insulating: >5 kv per mm. Withstands cold and heat in the range of 50 ºC ºC. Does not soften under intense heat (ball resistance at +50 ºC). Is self-extinguishing (does not propagate fire): HB0 classification and self-extinguishing in several seconds during the glow-wire test at 960 ºC 0 sec. Does not contain halogens. Releases little smoke and no toxic smoke in the event of combustion. Is light. Can be machined easily. Is corrosion-resistant: no rusting, and can withstand many chemical agents. Can resist bad weather. Characteristics of the production process of the polyester version The components of the enclosure (body and doors) are moulded by hot compression: the parts have an excellent finish on both sides and can include bosses for accommodating inserts and accessories for mounting or cable management.

23 Thalassa PLM ABS/PC wall-mounting enclosures 0 5 mm IP 66 Introduction Technical characteristics Monobloc wall-mounting enclosure made from ABS/PC, RAL 70 colour. Version with transparent polycarbonate door. Closes with a -mm double-bar lock. Door opening: 80. Degree of protection: 5 C C. Protection rating IP 66 according to IEC Resistance to external mechanical impacts of IK 0 (0 joules) according to IEC 66. Direct fixing of symmetrical rails ref. NSYCSPLM with plastic nuts ref. NSYTCSPLM, to be installed in the notches on the rear of the body, with a pitch of 5 mm. Fixing of installation plates on the studs at the rear of the enclosure. Back of the door with a 5-mm grid pattern. PB500 External dimensions (mm) References of wall-mounting enclosures with door Height Width Depth Plain* Transparent NSYPLM NSYPLMT *These enclosures are also available equipped with metallic or insulating mounting plates. See summary guide of the references on page 6. Dimensions 75 M DB006EN

24 Thalassa PLM Polyester wall-mounting enclosures mm IP 66 Introduction Technical characteristics PB5005 Monobloc wall-mounting enclosure made from polyester reinforced with fibreglass, moulded by hot compression, RAL 70 grey colour. Version with transparent tempered-glass door. Degree of protection IP 66 according to IEC Resistance to external mechanical impacts: Plain door enclosures IK 0 (0 joules). Glazed door enclosures IK 08 (5 joules) according to IEC 66. Closes with two -mm double-bar locks. Door opening angle: 0. Fixing of rear accessories on M8 8 studs. Grid pattern with a pitch of 50 mm on the back of the door. External dimensions (mm) References of wall-mounting enclosures with door Height Width Depth Plain* Transparent NSYPLM05 NSYPLM05T *These enclosures are also available equipped with metallic or insulating mounting plates. See summary guide of the references on page 6. Dimensions DB006EN

25 Thalassa PLM Polyester wall-mounting enclosures IP 66 Introduction PB505 Technical characteristics Monobloc wall-mounting enclosure made from polyester reinforced with fibreglass, moulded by hot compression, RAL 70 grey colour. Version with transparent tempered-glass door. Degree of protection IP 66 according to IEC Resistance to external mechanical impacts: Plain door enclosures IK 0 (0 joules). Glazed door enclosures IK 08 (5 joules) according to IEC 66. Locking device outside the sealed area, guaranteeing the tightness of IP 66 over time. Locking system: Enclosure height 87 mm: locks with double-bar insert or handle with key lock and -point closure. Enclosure height 056 mm: lock with double-bar insert and -point closure. Door opening angle: 80. Bosses for accessory-fixing inserts: M6 inside the enclosure, M5 in the door for enclosure heights of 0 and 50 mm, M6 in the door for enclosure heights 67 mm. Fixing of rear accessories on M8 studs, included in the standard supply. Direct fixing of symmetrical rails ref. NSYCS PLM, with plastic nuts, ref. NSYTCSPLM, to be installed in the notches on the rear of the body, with a pitch of 5 mm. Grid pattern with a pitch of 5 mm on the back of the door. PB5006 PB508 PB5007 PB509 PB506 PB507 Built-in canopy protecting the door and the sealing gasket. Two double-bar mm locks outside the sealed zone. Polyamide hinge pin, easily removable and captive. External dimensions (mm) References of wall-mounting enclosures with door Height (A) Width (B) Depth (C) Plain () Plain () Transparent Transparent () 0 0 NSYPLM NSYPLMV NSYPLMT NSYPLMTV 50 0 NSYPLM5 NSYPLM5V NSYPLM5T NSYPLM5TV NSYPLM6 NSYPLM6V NSYPLM6T NSYPLM6TV NSYPLM75 NSYPLM75V NSYPLM75T NSYPLM75TV NSYPLM86 NSYPLM86V NSYPLM86T NSYPLM86TV NSYPLM08 () - NSYPLM08T () - () Wall-mounting enclosure with handle and lock with -point closure and key E delivered as standard. () Wall-mounting enclosure with standard 5 mm double-bar lock and lock with -point closure. () These enclosures are also available equipped with metallic or insulating mounting plates. See summary guide of the references table on page 6.

26 Thalassa PLM Polyester wall-mounting enclosures IP 66 Dimensions A: Height B: Width C: Depth Ø8 M8 U E H V A M G K L D K B 5 C I N 6 DB006 F J O L Dimensions (mm) Bottom screw and door bosses (mm) Internal fixing (m) References A B C D E F G H I J K L M N O NSYPLM NSYPLM NSYPLM NSYPLM NSYPLM NSYPLM08 Glazed door opening (mm) References Glazed door opening (mm) References U V U V Y 7 9 NSYPLMT 7 5 NSYPLMTV 7 9 NSYPLM5T 7 5 NSYPLM5TV 6 9 NSYPLM6T 6 5 NSYPLM6TV 56 9 NSYPLM75T 56 5 NSYPLM75TV 66 9 NSYPLM86T 66 5 NSYPLM86TV NSYPLM08T DB006 X' Y' X 5 External fixing with lugs (mm) Vertical Horizontal References X Y X Y NSYPLM NSYPLM NSYPLM NSYPLM NSYPLM NSYPLM08 5

27 Thalassa PLM Polyester wall-mounting enclosure Selection guide Summary guide of the references PB500 PB5006 PB5007 PB506 PB5065 External dimensions (mm) ABS/PC wall-mounting enclosures IP 66 Polyester wall-mounting enclosures IP 66 Wall-mounting enclosures with plain door and mounting plate () Plain door Transp. door Plain door Transp. door Plain door Transp. door H W D -point closure -point closure Plain Bakelite Page Page and Page NSYPLM NSYPLMT NSYPLMP NSYPLMB NSYPLM05 NSYPLM05T - - NSYPLM05P NSYPLM05B NSYPLM NSYPLMT NSYPLMV NSYPLMTV NSYPLMP NSYPLMB NSYPLM5 NSYPLM5T NSYPLM5V NSYPLM5TV NSYPLM5P NSYPLM5B NSYPLM6 NSYPLM6T NSYPLM6V NSYPLM6TV NSYPLM6P NSYPLM6B NSYPLM75 NSYPLM75T NSYPLM75V NSYPLM75TV NSYPLM75P NSYPLM75B NSYPLM86 NSYPLM86T NSYPLM86V NSYPLM86TV NSYPLM86P NSYPLM86B NSYPLM08 NSYPLM08T NSYPLM08B () Not mounted. Summary guide of the characteristics References NSYPLM NSYPLM05 NSYPLM/5/6/75/86 NSYPLM08 Dimensions (mm) to Material ABS/PC Polyester Polyester Polyester Degree of protection IP 66 IP 66 IP 66 IP 66 Impact protection () IK 0 IK 0 IK 0 IK 0 Built-in canopy Yes No Yes Yes Lock () (-point closure) Closing with handle () - - (-point closure) - Lock outside the sealed area No No Yes Yes Door opening 80º 0º 80º 80º Notches every 5 mm () Yes No Yes Yes Grid pattern on the back of the door 5 mm 50 mm 5 mm 5 mm () IK 08 glazed door of the polyester enclosures. () With double-bar insert. () Handle with insert for key E. () Notches in the rear of the enclosure for quick installation of DIN rails. Wall-mounting enclosures with polyester mounting plate, machined or not, see customised offer. Specific Configured 6

28 Thalassa PLM Polyester wall-mounting enclosure Selection guide Mounting accessories PB5006 PB5006 PB5006 PB5006 PB50055 PB50056 PB50057 PB50058 PB50059 PB50060 PB5006 PB50007 PB50000 PB5000 PB5000 PB5000 PB5005 PB5005 PB5005 PB5005 External dimensions of the enclosures (mm) Metallic mounting plates Insulating mounting plates Modular distribution chassis Step slides Symmetrical DIN rail H W D Plain Silkscreened Microperforated Telequick Bakelite Polyester Page 7 Page Page NSYMM - - NSYMR NSYMB NSYMPP - - NSYCSPLM NSYMM NSYMR05 NSYMB05 NSYMPP05 NSYDLPLM NSYMM NSYMS NSYMF NSYMR NSYMB NSYMPP NSYDLA NSYDPLM NSYCS00PLM 50 0 NSYMM5 NSYMS5 NSYMF5 NSYMR5 NSYMB5 NSYMPP5 NSYDLA8 NSYDPLM NSYCS00PLM NSYMM6 NSYMS6 NSYMF6 NSYMR6 NSYMB6 NSYMPP6 NSYDLA8P NSYDPLM50 NSYCS00PLM NSYMM75 NSYMS75 NSYMF75 NSYMR75 NSYMB75 NSYMPP75 NSYDLA66 and NSYDLA88 NSYDPLM00 NSYCS500PLM NSYMM86 NSYMS86 NSYMF86 NSYMR86 NSYMB86 NSYMPP86 NSYDLA8 and NSYDPLM00 NSYCS600PLM NSYDLA NSYMM08 - NSYMF08 NSYMR08 NSYMB08 NSYMPP08 NSYDLA NSYDPLM50 NSYCS800PLM Main accessories External dimensions (mm) Fixing lugs Post-fixing device Floor-mounting pillar Coupling frame Cable-gland plate Internal door Blanking plates H W D Page 0 Page 0 Page 9 Page 9 Page 9 Page Page NSYPFPLM NSYCEPLMA NSYPFPLM NSYPA05PLM NSYPFPLM NSYSFP NSYPAP NSYCEPLMB 50 0 NSYPFPLM NSYSFP00 NSYSFSPLM - - NSYPAP5 NSYCEPLMB NSYPFPLM NSYSFP00 NSYSFSPLM - - NSYPAP6 NSYCEPLMC NSYPFPLM NSYSFP500 - NSYBUPLM NSYTLA0 NSYPAP75 NSYCEPLMC NSYPFPLM NSYSFP600 - NSYBUPLM NSYTLA0 NSYPAP86 NSYCEPLMC NSYPFPLM - - NSYBU08PLM NSYTLA60 NSYPAP08 - Document pocket Water drain plug Rail-fixing nuts Ventilation louvre Page 5 Page Page 5 7

29 Thalassa PLM Composition accessories Base accessories ZM plinth for PLM enclosure Designed to support and raise enclosures NSYPLM75, NSYPLM86 and NSYPLM08. Polyester material reinforced with fibreglass, moulded by hot compression. Guarantees total insulation according to IEC 69-. Ensures a degree of protection of IP and impact resistance of IK 0. Plinth height of mm; stackable to obtain a 00-mm plinth. Four floor-attachment points; the symmetry of the parts prevents incorrect assembly. PB5079 PB5078 PB5076 PB5077 The frontal parts of the plinth (front and rear) have two stainless-steel screws protected by a plastic cap; these screws make it possible (using an Allen key) to open and remove the frontal parts for easier cable installation. In stacked position, the bottom plinth can be partially buried. It is provided with one transverse reinforcement rail, adjustable to adapt to the position of the cables. The reference of the plinth contains all the accessories required for attaching the enclosure to the plinth and for stacking two plinths. For enclosure Plinth Cabling area Height Width Depth Reference Height Width Depth Reference Width Depth NSYPLM NSYZM NSYPLM NSYZM NSYPLM NSYZM Cable supporting cross-rail The lateral sides of the plinths are provided with bosses for attaching cross-rails with cut-out profiles, for supporting cables. The reference of the cross-rail includes all the elements required for assembly. For plinth NSYZM5 NSYZM6 NSYZM8 Kit for IP 5 Cross-rail NSYAC80 NSYAC60 NSYAC600 Makes it possible to obtain IP 5 for the plinth and the plinth-enclosure coupling. Ref. NSYAEPZM. Feet for partially buried installation Allows the partially buried installation of plinths before completion of the floor. The plinths are attached by four feet with a standard length of 750 mm. Possibility of horizontal adjustment of the plinth. The reference includes a kit made up of four feet and fixings. Ref. NSYAEBFZ. 8

30 Thalassa PLM Composition accessories Coupling accessories Coupling frame Allows the lateral coupling of enclosures. Polyester frame, RAL 70 colour and fixings. A built-in sealing gasket guarantees a protection rating of IP PB50058 External dimensions (mm) Entry For wall-mounting enclosure References NSYPLM75 and NSYPLM86 NSYBUPLM NSYPLM08 NSYBU08PLM Base accessories Floor-mounting pillar To protect cables entering the enclosure in outdoor installations. Material: polyester reinforced with fibreglass. RAL 70 grey colour. Delivered with steel frame for secure fixing to the floor. Cable entry section: mm. For enclosures ref. NSYPLM5, NSYPLM5T, NSYPLM6 and NSYPLM6T. Name Floor-mounting pillar Reference NSYSFSPLM PB50 DB DB Cable-entry accessories PB50059 Cable-gland plates Material: polyester. Dimensions: 5 85 mm and mm. For wall-mounting enclosures NSYPLM75 and NSYPLM86 NSYPLM08 References NSYTLA0 NSYTLA60 9

31 Thalassa PLM Composition accessories Fixing accessories The enclosures can be mounted directly on the walls. The seals and caps supplied as standard with the enclosure guarantee that it maintains its degrees of protection and insulation. PB50 PB500 PB50055 NSYPFPLM NSYPFPLM NSYPFXPLM PB50 Wall-fixing lugs Set of wall-fixing lugs. Mounted directly on the enclosure, either in horizontal position or in vertical position. Available in versions, polyamide loaded with fibreglass or stainless steel. Delivered with fixings. Acceptable load of 00 kg in vertical position and 00 kg in horizontal position. Material References Polyamide NSYPFPLM () Stainless steel NSYPFXPLM () () Single reference in polyamide, ref. NSYPFPLM, for enclosure ref. NSYPLM and NSYPLMT. Post-fixing device For outdoor installations on a post with a maximum circumference of 675 mm, Ø 5 mm. Material: galvanised steel. Supply of the rail, the strips and the fixings. Maximum load: 00 kg. PB50056 For wall-mounting enclosure References NSYPLM NSYSFP00 () NSYPLM5 and NSYPLM6 NSYSFP00 NSYPLM75 NSYSFP500 NSYPLM86 NSYSFP600 () NSYSFP00 can be used for fixation of NSYPLM; the length of the cross rail is slightly larger than enclosure. Blanking plates Made from thermoplastic material, they are positioned on the rear surface of the enclosures to block the openings in the corners in order to improve their appearance or prevent the entry of unwanted elements in the ventilation shaft. Supplied as standard for enclosure, ref. NSYPLM08. PB50 For wall-mounting enclosure NSYPLM NSYPLM and NSYPLM5 NSYPLM6, 75 and 86 References NSYCEPLMA NSYCEPLMB NSYCEPLMC 0

32 Thalassa PLM Composition accessories Door and door accessories Internal door Reversible door made from polyester reinforced with fibreglass, self-extinguishing, RAL 70 grey. Grid pattern with a pitch of 5 mm for easier marking out before drilling. Closes with double-bar locks. Door handle. Delivered with fixings and brass inserts. Steel internal door, without grid pattern and locking by a screw, for enclosures ref. NSYPLM05. Incompatible with the modular distribution chassis. PB505 B C DB0066 A D For wall-mounting enclosure (mm) Dimensions (mm) Height Width A B C D References NSYPA05PLM NSYPAP NSYPAP NSYPAP NSYPAP NSYPAP NSYPAP08

33 Thalassa PLM Composition accessories Locking system PB506 Locks and inserts for enclosures with H 87 mm The ABS/PC 0 5 mm enclosure is supplied with a lock with a double-bar insert as standard. The mm enclosure is supplied with two locks with a double-bar insert as standard. The polyester enclosures from 0 to 87 mm high are delivered as standard with: locks with double-bar insert, ref. NSYCDBPLM. Or a -point closure with handle and lock with key E (enclosures NSYPLM V). Double-bar insert ref. NSYTDBCRN, is placed in a rectangular escutcheon. A plastic key, ref. NSYDBP, enabling the opening of the double-bar insert, is included in the standard supply. This key can be fixed to the double-bar system to remain on the enclosure and be used as a handle. NSYTC6CRN NSYTC7CRN NSYTC8CRN Options to transform the locks with double-bar inserts Changing the shape inserts for locks with keys according to the following table: PB507 NSYTHLEPLM NSYTHL05PLM NSYTHLPLM NSYTHL55PLM NSYTHLAPLM NSYTHLAPLM NSYTHLAPLM NSYTHPLM NSYTT6CRN NSYTT8CRN NSYTL05PLM NSYTL0PLM Name References 6 mm male square NSYTC6CRN 7 mm male square NSYTC7CRN 8 mm male square NSYTC8CRN 6.5 mm male triangle NSYTT6CRN 8 mm male triangle NSYTT8CRN Lock and key 05 NSYTL05PLM Lock and key 0 NSYTL0PLM Replacement for locking handle with cylindrical barrel, delivered with all the parts required to change the lock. Type of barrel Key E Key 05 Key Key 55 Key A Key A Key A Manual References NSYTHLEPLM NSYTHL05PLM NSYTHLPLM NSYTHL55PLM NSYTHLAPLM NSYTHLAPLM NSYTHLAPLM NSYTHPLM Options to transform versions NSYPLM V, with retractable handle and -point closure Transformation of the standard insert (barrel for key E, ref. NSYTLEME) for other shape inserts or barrels according to the following table: PB508 Name References 5 mm double bar NSYTDB5ME 6 mm male square NSYTC6ME 7 mm male square NSYTC7ME 8 mm male square NSYTC8ME 6.5 mm male triangle NSYTT6ME 8 mm male triangle NSYTT8ME Barrel and key 05 NSYTCL05ME Reinforced key and barrel NSYTLRME JIS key and barrel NSYTLJISME Manual NSYTMME

34 Thalassa PLM Composition accessories Locking system Locks and inserts for enclosures NSYPLM08/T Enclosures delivered as standard with 5 mm double-bar insert. Insert ref. NSYTDB5PL, placed in a long rectangular escutcheon, activates a -point closure system. Options to transform the insert The standard insert can be replaced with other shape inserts, according to the following table: PB509 Name References DB0068 DB mm male square NSYTC6PL 7 mm male square NSYTC7PL 8 mm male square NSYTC8PL 6.5 mm male triangle NSYTT6PL 7 mm male triangle NSYTT7PL 8 mm male triangle NSYTT8PL Options to transform for a retractable handle The escutcheon and rosette assembly can be replaced with a lock with retractable handle equipped with inserts or barrels, according to the following table: PB500 Name References 5 mm double bar NSYTEDB5PL 6 mm male square NSYTEC6PL 7 mm male square NSYTEC7PL 8 mm male square NSYTEC8PL 6.5 mm male triangle NSYTET6PL 7 mm male triangle NSYTET7PL 8 mm male triangle NSYTET8PL Lock key E NSYTELEPL Barrel and key 05 NSYTEL05PL Reinforced key and barrel NSYTERPL JIS key and barrel NSYTELJISPL FAC key and barrel NSYTELFACPL Manual NSYTEMPL PB50 Padlocking accessories Padlocking system, ref. NSYKPLM, positioned around the rectangular escutcheon of the enclosures with a height of 87 mm to block access to the lock; for a 9 mm padlock. Padlocking system, ref. NSYBCPL, positioned around the long rectangular escutcheon of the enclosures ref. NSYPLM08/T, to block access to the lock; for a 9 mm padlock. Padlocking system, ref. NSYBCME, to block access to the retractable handle, for the versions NSYPLM V or optionally for enclosures ref. NSYPLM08/T, for a 9 mm padlock.

35 Thalassa PLM Mounting accessories Step slides For depth adjustment of the mounting plate Kit including step slides with brackets, allowing depth adjustment with a pitch of.5 mm, and the fixings required for the installation. Material: galvanised steel. Incompatible with the modular distribution chassis. PB5009 For wall mounting enclosure Depth adjustment Depth (mm) Dimension A (mm) Dimension B (mm) References 56 9 NSYDPLM NSYDPLM NSYDPLM NSYDPLM50 DB0069 B A PB5006 Plastic nuts for rail fixing They slide directly into the notches, with a pitch of 5 mm, which are located on the rear of the enclosures, except enclosure ref. NSYPLM05/T. They allow direct fixing of symmetrical DIN rails by self-tapping screws. Option of raising the rails with an M6 spacer using a plastic nut containing an M6 nut. References by unit. Order by multiples of 0 units (0, 0, 60, etc.). Name Plastic nut with self- tapping screw Plastic nut containing an M6 metal nut References NSYTCSPLM NSYTCSM6PLM 5 mm symmetrical DIN rails They are fixed to the rear of the enclosure without uprights, with a pitch of 5 mm for the notches on the rear of the enclosure, with the help of direct-fixing nuts ref. NSYTCSPLM or NSYTCSM6PLM. Treated steel. PB50 References by unit. Order by multiples of units (,, 6, etc.). For wall mounting enclosure Rail length (mm) Width (mm) References 80 5 NSYCSPLM 80 0 NSYCS00PLM 80 0 / 6 NSYCS00PLM NSYCS500PLM NSYCS600PLM 7 85 NSYCS800PLM

36 Thalassa PLM Accessories Diverse Fixing inserts PB50 NSYTEX8 NSYTEX6 NSYTEX5 Expanding inserts for addition to the M6 bosses of the enclosure, the M5 or M6 bosses of the door and the M8 bosses of the external rear part of the enclosure. M5 and M6 inserts to be ordered in multiples of 0. References by unit. Order by multiples of 8 units (8, 6,, etc.). Insert size For wall-mounting enclosure References M5 NSYPLM and NSYPLM5 NSYTEX5 M6 NSYPLM6 and NSYPLM08 NSYTEX6 M8 For the rear of the enclosure NSYTEX8 Ventilation louvres PB5006 NSYCAG5LP They can be positioned inside the wall-mounting enclosures with heights of 0 to 86 mm, allowing ventilation through the channels of the enclosure. The IP on the rear of the enclosures is IP. * References by unit. Order by multiples of units (,, 6, etc.). Ventilation louvres, airing Name Reference devices with filters, fans and thermal adjustment Ventilation louvres NSYCAG5LP accessories, see ClimaSys section. Water drain plug PB5006 NSYVEA9 For drainage of condensation water. It is placed in the 9 mm housing at the bottom of the enclosure. IP 55. References by unit. Order by multiples of 0 units (0, 0, 0, etc.). Name Water drain plug Reference NSYVEA9 Renovation and anti-graffiti paint Paint system with components (base 80% + hardener 0%), specially designed for polyester enclosures, for their renovation and/or as prevention to allow easy removal of graffiti. The kg reference includes pot with 800 g of base paint and g of hardener. It is enough to paint a surface of around 5 m. The 5 kg reference includes pot with kg of base paint and kg of hardener. It is enough to paint a surface of around 5 m. RAL 70 colour. Solvent for diluting the paint and cleaning the utensils. PB5009 Name Anti-graffiti paint kg Anti-graffiti paint 5 kg Anti-graffiti paint solvent 500 g References NSYAUPG NSYAUPG5 NSYAUPGS 5

37 Thalassa PLM Power distribution accessories Modular distribution accessories Technical characteristics PB50 Dinimel DLA modular chassis Front panels and finish covers, made from self-extinguishing insulating material RAL 70 colour. Rigid galvanised-steel structure, for the installation of modular devices. Front panels and covers installed in the front part, are not depth adjustable. Open front panels with 5 mm DIN rail and plain front panels with mounting plate, according to the model. Quick installation with no fixings. Shoulder height adjustable from 0 to 85 mm. System for standard circuit marking. Incompatible with the internal doors and the step slides. Neutral / earth strip: 6 mm 5 6 mm. For ranges SD*, CRN, SX, PLM * Minimum depth mm. Dimensions (mm) Distribution rows For installation in the enclosures A B C D min. E min. Nº of useful rows No. of 8 mm modules per row No. of 8 mm modules No. of plates PLM enclosure SD (depth mm) or CRN enclosure References References Height Width NSYPLM NSYPLMT NSYDLA NSYPLM5 NSYPLM5T NSYDLA NSYPLM6 NSYPLM6T NSYDLA8P NSYPLM75 NSYPLM75T NSYDLA NSYPLM75 NSYPLM75T NSYDLA NSYPLM86 NSYPLM86T NSYDLA NSYPLM86 NSYPLM86T NSYDLA NSYPLM08 NSYPLM08T NSYDLA NSYDLA NSYDLA8 NSYDLA8P NSYDLA66 NSYDLA88 DB0060 NSYDLA8 NSYDLA NSYDLA 6

38 Thalassa PLM Power distribution accessories Modular distribution accessories Dimensions (mm) DB006 * Models NSYDLA8P, 66, 88, 8 and. PB505 Plain front panels for Dinimel DLA chassis Front panel made from RAL 70 self-extinguishing insulating material for nonmodular device protection, on one row. To be ordered in multiples of. For installing on the chassis Width (mm) References NSYDLA 56 NSYCTL00DLA NSYDLA8 and NSYDLA8P 56 NSYCTL00DLA NSYDLA66 and NSYDLA88 56 NSYCTL500DLA NSYDLA8 and NSYDLA 555 NSYCTL600DLA NSYDLA 755 NSYCTL800DLA Mounting plate for Dinimel DLA chassis Galvanised-steel mounting plate for mounting non-modular devices, on one row. To be ordered in multiples of. PB506 For installing on the chassis Width (mm) References NSYDLA8 and NSYDLA8P 5 NSYPMP00DLA NSYDLA66 and NSYDLA88 5 NSYPMP500DLA NSYDLA8 and NSYDLA 5 NSYPMP600DLA NSYDLA 7 NSYPMP800DLA Modular distribution chassis for enclosure ref. PLM05/T Metal chassis and protective plate in insulating material. For mounting modular devices on two rows of nine 8-mm modules. Name Modular distribution chassis Reference NSYDLPLM8 7

39 Thalassa PLM PLM customised solution Configured and specific Solution guide PB508 Thalassa PLM configured or specific polyester wall-mounting enclosures The configured offer anticipates the most common needs and can optimise delivery times. It only includes polyester enclosures. The configurator on the next page defines the limits of this offer and helps you cost this solution. The specific offer allows the greatest variety of customisations. Help to define a specific need is presented on page 7. The advantages and examples of customised solutions are presented on pages 5 and 6. Part Service Body and door Body Door Mounting plates and rails Cable-gland plates and accessories Minimum amount Maximum amount Special colour of the material Paint colour Anti-graffiti paint Horizontal coupling Mounting back-to-back Body machining on all surfaces () Lugs at a given location Mounting (or supply) of standard accessories of the configured offer () Mounting (or supply) of other standard accessories of Thalassa PLM Mounting (or supply) of other standard common accessories Machining in the door () Special glass (dimensions) or window Standard catalogue locks () Special locks not included in the catalogue Mounting (or supply) of standard accessories of the configured offer () Mounting (or supply) of other standard accessories of Thalassa PLM Mounting (or supply) of other standard common accessories Standard mounting plate Special mounting plate Special machining of mounting plate Installation of common cable-gland plates and/or cable entries Installation of common cable-management accessories Thermal Installation of airing devices, fans () Diverse Machining of the internal door or the cable-gland plates Special installation accessories: plinths, external mounting plates, supports, etc. Other accessories Special marking Special packaging () See areas in DXF diagram. () The accessories included or installed in the configured offer are shown in the configuration sheet on the next page. Configured Specific To be studied To be studied To be studied To be studied 8

40 Thalassa PLM PLM configured solution Configuration sheet Document to be sent to your sales office by or fax Configured YOUR CONTACT DETAILS PB508 Full name: Company: Address: Tel.: Fax: NUMBER OF ENCLOSURES REFERENCE OR CATALOGUE DIMENSIONS (mm) GLAZED DOOR PLAIN DOOR HEIGHT WIDTH DEPTH HINGES ON THE LEFT 07 / 0 / 50 / 67 / 77 / 87 / 056 / 55 / 0 / 0 / 6 / 56 / 66 / 85 / Choice of standard configured accessories Also tick the red box m for accessories installed at the plant. LUGS POLYESTER STAINLESS STEEL REAR MOUNTING PLATE PLAIN TELEQUICK MODULAR CHASSIS m m m OUTLET GRILLE REF. NSYCAG5LPF (RAL 705) m INTERNAL DOOR (installed) DOCUMENT LIP FAN REF. NSYCVF85M0PF (RAL 705) THERMOSTAT REF. NSYCCOTHO m PB508 LOCK MODIFICATION SQUARE 7 mm SQUARE 8 mm TRIANGLE 8 mm PADLOCKING PURGE m STEP SLIDES m INTERNAL VENTILATION LOUVRES (SET OF ) m * Eventual incompatibilities between accessories can't be considered in configurator sheet. 9

41 Thalassa PLM PLM configured solution Configuration sheet Configured PB508 Machining For a quick calculation, please indicate the total number of machining operations required: ON THE BODY (REAR AND SURFACES) FOR GRILLES, FANS, PURGES AND AIRING DEVICES OTHER MACHINING OPERATIONS ON THE DOOR NOTE: Every drill-hole or cut-out counts as a machining operation. The machining areas are indicated on the DXF diagrams. Download the configuration sheets and the DXF diagrams from our websites. Send them back to your sales office with your modifications. Mandatory when ordering to guarantee configured offer delivery times. Specific Other needs, other constraints? contact us. A specific offer will meet all your requirements. Help to define a specific need is presented on page 7. *Advantages of our customised offer and implementation examples. See pages 5 and 6. 0

42

43 Thalassa PLA Polyester floor-standing enclosures Safety Full insulation (to create class II units). No risk to the public. Lock with or -point closure. Service life High resistance to corrosion in harsh environments, maintaining its mechanical and insulation properties. Protection IP or 5 and IP 65 in the industrial version. Polyurethane gasket. Lock outside sealed area. Choice enclosure versions, available in 0 dimensions with -door versions. Smart Door with ripped surface to avoid posting. Reversible door (-door enclosure). Numerous fixing bosses on the doors and panels. Easy Opening to 0 or 80. The central upright can be removed. Numerous fixing points. PB507 Applications Industry or infrastructures in harsh environments. Accessories for modular distribution and 9". Customisation Configured: machining and accessories. Specific: non-standard colours and accessories. Every possible combination of versions and doors, front and rear, not included in the standard offer.

44 Thalassa PLA General characteristics of the floor-standing enclosure Indoor or outdoor use. versions: Completely sealed enclosure (PLA version). Enclosure with ventilated canopy (PLAT version). Enclosure with plinth-type open bottom (PLAZ version). Enclosure with plinth-type open bottom and ventilated canopy (PLAZT version). Note: The first letters of the references relate to the version. 0 dimensions: 5 heights: 500, 750, 000, 50, 500 mm. widths: 500 and 750 ( door), 000 and 50 mm ( doors). depths: 0 and 0 mm. Note: The figures included in the references of the enclosures and products of the range represent the dimension in dm of the product in question. The -door enclosures comprise a central upright, which can be removed in certain conditions. Please contact us. types of door: Plain door. Door with transparent window (index T at the end of the reference). Door with anti-posting surface (index R at the end of the reference). Protection degree IP 65 or IP 5 according to standard IEC Impact resistance IK 0 for the plain doors and all sides and IK 08 for the glazed door. -point closure for heights of 500 and 750 mm and -point closure points for heights 000 mm. Complies with enclosure standard IEC 608 for: IP, IK, resistance to heat and fire, insulation 5000 V, resistance to bad weather and corrosion and resistance to internal loads (50 kg/m ) and loads on the door (0 kg/m ). Full insulation to create class II units according to IEC 69- UL certification and NEMA classification X, 5, and, depending on the version Complies with RoHS and REACH Directives Characteristics of the material The floor-standing enclosures are made from polyester reinforced with fibreglass, moulded by hot compression, RAL 70 grey. This material: Is insulating: > 5 kv per mm. Can be machined easily. Is resistant to corrosion: does not rust and can withstand many chemical substances. Resists bad weather (rain, UV). Withstands cold and heat in the range of 50 C +50 C. Does not soften under heat (ball resistance at +50 C). Is self-extinguishing (does not propagate fire: HB0 classification and self-extinguishing in several seconds during the glow-wire test at 960 C during 0 s.). Does not contain halogens. Releases little smoke and nontoxic smoke in the case of combustion. Is light. Characteristics of the production process The components of the enclosures (the various sides and doors) are moulded by hot compression: the pieces have an excellent finish on both sides and can include numerous bosses for accommodating inserts and mounting or cable management accessories.

45 Thalassa PLA Completely sealed enclosures, IP 65 Introduction Characteristics of the PLA version Enclosure obtained by assembling: sealed top part. sealed bottom part. side parts. or rear panels (according to width). or doors (according to width). Indoor use. Outdoor use possible with a canopy (to be ordered separately). Protection degree IP 65 according to IEC Locking system with escutcheon and 5-mm double-bar insert, included in the standard supply. Other inserts or locks with handles optionally available. Door opening to 0. Direct fixing to the floor or by means of a plinth with a height of 60 mm, as an option, see page 5. Possibility of fixing on a semi-embedded plinth, see page 55. Optional wall-fixing lugs. PB505 Completely sealed enclosure with plain door. PB50065 PB50066 PB50067 External dimensions (mm) References of enclosures with door PB505 Transparent door made from polyester and tempered glass. PB5009 PB5055 Escutcheon with double-bar insert. Detail from the internal locking system. Height Width Depth N of doors Plain Glazed Anti-posting NSYPLA55 NSYPLA55T NSYPLA55R NSYPLA55 NSYPLA55T NSYPLA55R NSYPLA57 NSYPLA57T NSYPLA57R NSYPLA57 NSYPLA57T NSYPLA57R NSYPLA50 NSYPLA50T NSYPLA50R NSYPLA50 NSYPLA50T NSYPLA50R NSYPLA5 NSYPLA5T NSYPLA5R NSYPLA5 NSYPLA5T NSYPLA5R NSYPLA75 NSYPLA75T NSYPLA75R NSYPLA75 NSYPLA75T NSYPLA75R NSYPLA77 NSYPLA77T NSYPLA77R NSYPLA77 NSYPLA77T NSYPLA77R NSYPLA70 NSYPLA70T NSYPLA70R NSYPLA70 NSYPLA70T NSYPLA70R NSYPLA7 NSYPLA7T NSYPLA7R NSYPLA7 NSYPLA7T NSYPLA7R NSYPLA05 NSYPLA05T NSYPLA05R NSYPLA05 NSYPLA05T NSYPLA05R NSYPLA07 NSYPLA07T NSYPLA07R NSYPLA07 NSYPLA07T NSYPLA07R NSYPLA00 NSYPLA00T NSYPLA00R NSYPLA00 NSYPLA00T NSYPLA00R NSYPLA0 NSYPLA0T NSYPLA0R NSYPLA0 NSYPLA0T NSYPLA0R NSYPLA5 NSYPLA5T NSYPLA5R NSYPLA5 NSYPLA5T NSYPLA5R NSYPLA7 NSYPLA7T NSYPLA7R NSYPLA7 NSYPLA7T NSYPLA7R NSYPLA0 NSYPLA0T NSYPLA0R NSYPLA0 NSYPLA0T NSYPLA0R NSYPLA NSYPLAT NSYPLAR NSYPLA NSYPLAT NSYPLAR NSYPLA55 NSYPLA55T NSYPLA55R NSYPLA55 NSYPLA55T NSYPLA55R NSYPLA57 NSYPLA57T NSYPLA57R NSYPLA57 NSYPLA57T NSYPLA57R NSYPLA50 NSYPLA50T NSYPLA50R NSYPLA50 NSYPLA50T NSYPLA50R NSYPLA5 NSYPLA5T NSYPLA5R NSYPLA5 NSYPLA5T NSYPLA5R

46 Thalassa PLA Enclosures with ventilated canopy IP Introduction Characteristics of the PLAT version PB5005 Enclosure obtained by assembling: open top part with canopy. sealed bottom part. side parts. or rear panels (according to width). or doors (according to width). Outdoor use. Protection degree IP according to IEC Protection degree IP 5 with or internal grilles, ref. NSYCAG5LPF, to be ordered separately. Locking system with handle with a 5-mm double-bar insert block, included in the standard supply. Other blocks with inserts or barrels and keys optionally available. Door opening to 0. Direct fixing to the floor or by means of a plinth with a height of 60 mm, as an option, see page 5. Possibility of fixing on a semi-embedded plinth, see page 55. Optional wall-fixing lugs. Enclosure with ventilated canopy and plain door. PB50070 PB5007 PB5009 PB5056 Open top part with canopy allowing for ventilation. External handle. PB5057 Door with anti-posting surface and additional reinforcement. External dimensions (mm) References of enclosures with door Height Width Depth N of doors Plain Anti-posting NSYPLAT55 NSYPLAT55R NSYPLAT55 NSYPLAT55R NSYPLAT57 NSYPLAT57R NSYPLAT57 NSYPLAT57R NSYPLAT50 NSYPLAT50R NSYPLAT50 NSYPLAT50R NSYPLAT5 NSYPLAT5R NSYPLAT5 NSYPLAT5R NSYPLAT75 NSYPLAT75R NSYPLAT75 NSYPLAT75R NSYPLAT77 NSYPLAT77R NSYPLAT77 NSYPLAT77R NSYPLAT70 NSYPLAT70R NSYPLAT70 NSYPLAT70R NSYPLAT7 NSYPLAT7R NSYPLAT7 NSYPLAT7R NSYPLAT05 NSYPLAT05R NSYPLAT05 NSYPLAT05R NSYPLAT07 NSYPLAT07R NSYPLAT07 NSYPLAT07R NSYPLAT00 NSYPLAT00R NSYPLAT00 NSYPLAT00R NSYPLAT0 NSYPLAT0R NSYPLAT0 NSYPLAT0R NSYPLAT5 NSYPLAT5R NSYPLAT5 NSYPLAT5R NSYPLAT7 NSYPLAT7R NSYPLAT7 NSYPLAT7R NSYPLAT0 NSYPLAT0R NSYPLAT0 NSYPLAT0R NSYPLAT NSYPLATR NSYPLAT NSYPLATR NSYPLAT55 NSYPLAT55R NSYPLAT55 NSYPLAT55R NSYPLAT57 NSYPLAT57R NSYPLAT57 NSYPLAT57R NSYPLAT50 NSYPLAT50R NSYPLAT50 NSYPLAT50R NSYPLAT5 NSYPLAT5R NSYPLAT5 NSYPLAT5R PB5058 Various bosses for M8 inserts. 5

47 Thalassa PLA Enclosures with plinth-type open bottom part, IP 5 Introduction PB5059 Enclosure with open bottom part. PB5006 Characteristics of the PLAZ version Enclosure obtained by assembling: sealed top part. plinth-type open bottom part. side parts. or rear panels (according to width). or doors (according to width). Indoor use. Outdoor use with a canopy (to be ordered separately). Protection degree IP 5 according to IEC 6059, for the 5 sides of the enclosure. Locking system with handle with a 5 mm double-bar insert block, included in the standard supply. Other blocks with inserts or barrels and keys optionally available. Door opening to 0. The open bottom part forms a 60 mm plinth which is fixed to the floor directly or by means of an optional fixing frame, see page 55, or else it is installed on a semi-embedded plinth, see page 5. PB50068 PB50069 External dimensions (mm) References of enclosures with door Height Width Depth N of doors Plain Anti-posting PB5060 PB5008 PB506 Polyurethane sealing gasket and 0 hinge. Detail from the plinth-type bottom part, equipped with a cable-entry plate (optional). Plain mounting plate installed on step slides and compulsory adapter plates in all the enclosures with open bottom part NSYPLAZ55 NSYPLAZ55R NSYPLAZ55 NSYPLAZ55R NSYPLAZ57 NSYPLAZ57R NSYPLAZ57 NSYPLAZ57R NSYPLAZ50 NSYPLAZ50R NSYPLAZ50 NSYPLAZ50R NSYPLAZ5 NSYPLAZ5R NSYPLAZ5 NSYPLAZ5R NSYPLAZ75 NSYPLAZ75R NSYPLAZ75 NSYPLAZ75R NSYPLAZ77 NSYPLAZ77R NSYPLAZ77 NSYPLAZ77R NSYPLAZ70 NSYPLAZ70R NSYPLAZ70 NSYPLAZ70R NSYPLAZ7 NSYPLAZ7R NSYPLAZ7 NSYPLAZ7R NSYPLAZ05 NSYPLAZ05R NSYPLAZ05 NSYPLAZ05R NSYPLAZ07 NSYPLAZ07R NSYPLAZ07 NSYPLAZ07R NSYPLAZ00 NSYPLAZ00R NSYPLAZ00 NSYPLAZ00R NSYPLAZ0 NSYPLAZ0R NSYPLAZ0 NSYPLAZ0R NSYPLAZ5 NSYPLAZ5R NSYPLAZ5 NSYPLAZ5R NSYPLAZ7 NSYPLAZ7R NSYPLAZ7 NSYPLAZ7R NSYPLAZ0 NSYPLAZ0R NSYPLAZ0 NSYPLAZ0R NSYPLAZ NSYPLAZR NSYPLAZ NSYPLAZR NSYPLAZ55 NSYPLAZ55R NSYPLAZ55 NSYPLAZ55R NSYPLAZ57 NSYPLAZ57R NSYPLAZ57 NSYPLAZ57R NSYPLAZ50 NSYPLAZ50R NSYPLAZ50 NSYPLAZ50R NSYPLAZ5 NSYPLAZ5R NSYPLAZ5 NSYPLAZ5R 6

48 Thalassa PLA Enclosures with plinth-type open bottom part and ventilated canopy, IP Introduction Characteristics of the PLAZT version PB506 Enclosure with plinth-type open bottom part, ventilated canopy and anti-posting door. Enclosure obtained by assembling: open top part with canopy. plinth-type open bottom part. side parts. or rear panels (according to width). or doors (according to width). Outdoor use. Protection degree IP according to IEC 6059, for the 5 sides of the enclosure. Protection degree IP 5 with or internal grilles, ref. NSYCAG5LPF, to be ordered separately. Locking system with handle with a 5 mm double-bar insert block. Other blocks with inserts or barrels and keys optionally available. Door opening to 80. Anti-lever system to prevent forcing of the door. The open bottom part forms a 60 mm plinth which is fixed to the floor directly or by means of an optional fixing frame, see page 55, or else it is installed on a semi-embedded plinth, see page 5. PB5007 PB506 PB5065 PB5007 Door opening to 80. Bottom part open for underground cable access. PB5066 PB506 M8 fixing bosses on the inside of the door. Anti-lever security system. External dimensions (mm) References of enclosures with door Height Width Depth N of doors Plain Anti-posting NSYPLAZT55 NSYPLAZT55R NSYPLAZT55 NSYPLAZT55R NSYPLAZT57 NSYPLAZT57R NSYPLAZT57 NSYPLAZT57R NSYPLAZT50 NSYPLAZT50R NSYPLAZT50 NSYPLAZT50R NSYPLAZT5 NSYPLAZT5R NSYPLAZT5 NSYPLAZT5R NSYPLAZT75 NSYPLAZT75R NSYPLAZT75 NSYPLAZT75R NSYPLAZT77 NSYPLAZT77R NSYPLAZT77 NSYPLAZT77R NSYPLAZT70 NSYPLAZT70R NSYPLAZT70 NSYPLAZT70R NSYPLAZT7 NSYPLAZT7R NSYPLAZT7 NSYPLAZT7R NSYPLAZT05 NSYPLAZT05R NSYPLAZT05 NSYPLAZT05R NSYPLAZT07 NSYPLAZT07R NSYPLAZT07 NSYPLAZT07R NSYPLAZT00 NSYPLAZT00R NSYPLAZT00 NSYPLAZT00R NSYPLAZT0 NSYPLAZT0R NSYPLAZT0 NSYPLAZT0R NSYPLAZT5 NSYPLAZT5R NSYPLAZT5 NSYPLAZT5R NSYPLAZT7 NSYPLAZT7R NSYPLAZT7 NSYPLAZT7R NSYPLAZT0 NSYPLAZT0R NSYPLAZT0 NSYPLAZT0R NSYPLAZT NSYPLAZTR NSYPLAZT NSYPLAZTR NSYPLAZT55 NSYPLAZT55R NSYPLAZT55 NSYPLAZT55R NSYPLAZT57 NSYPLAZT57R NSYPLAZT57 NSYPLAZT57R NSYPLAZT50 NSYPLAZT50R NSYPLAZT50 NSYPLAZT50R NSYPLAZT5 NSYPLAZT5R NSYPLAZT5 NSYPLAZT5R 7

49 Thalassa PLA Polyester floor-standing enclosures Dimensions Sealed enclosure A 5 A () B () A () B () () C DB006EN B B 50 () () A 50 () 75 B 50 () 5 () A 50 () C 8 C 0 A C A Enclosure with ventilated canopy A () B () A A () () () () B B A () B () A A () () () () B B () C 8 () () C C 8 8 DB0065EN B 50 () () A 50 () B 50 B 50 () () () () A 50 () A 50 () 75 B 50 () 5 () A 50 () B 50 B 50 () () () () A 50 () A 50 () 5 5 A 55 C 8 C C 60 A+8 C 8 C 8 C 0 C 0 A 55 A C C A+8 A+8 Common top views B 0 B 0 () () C 0 M8 / 8(5) 5 C 5() () C 0 B () 0 7 M8 5 C 5() DB0066 B B = 500/750 () 05 () 05/655 () /750 (6) B =000/50 8

50 Thalassa PLA Polyester floor-standing enclosures Dimensions Enclosure with plinth-type open bottom part A () B () A () B () () C 7.5 () A 50 () 75 () A 50 () C 8 C A A+55 DB0067EN B 50 () B 50 () C 55 Enclosure with ventilated canopy and plinth-type open bottom part 7.5 DB0068EN A- () () () B- () A B-50 A 5 A- () () B- () A () B () B 5 () () B-50 B 50 () A 50 A-50 () B A- () () () B- 5 () A-50 B B 50 () A- () () () B- () A () B () 5 5 () A-50 A 50 () DB0069EN () C-70 A- C C- () C 8 C 0 5 A 55 A C C-8 C C A+9 60 A Common top views B 8 B 60 () C 68 /8 (5) M8 C 60 () B 8 B 60 () B 60 () C 68 /8 (5) M8 C 60 () 0 B 8 7 C 68 M8 C 60 () DB0060EN B = 500/ B = 500/ () 05/655 () /750 (6) 6.5 B =000/ () bosses with M8 inserts and studs for direct fixing of mounting plates. () Bosses designed to accommodate M8 inserts, ref. NSYTEX8. They are placed: On the back of the enclosure, from the height of 000 mm. They allow the fixing of partial mounting plates and assorted equipment. On the top and bottom parts of the enclosure. They are used for fixing the step slides, an internal door, 9" chassis, etc. () Dimensions for fixing on the floor or on a plinth. () Entry dimensions, door open. (5) Dimension of 8 mm for enclosures with heights of more than 000 mm (height after the installation of the plain mounting plates with reinforcement foldings). (6) With a width of 50 mm in standard supply, 500-mm door on the left and 750-mm door on the right. 9

51 Thalassa PLA Polyester floor-standing enclosures Accessory selection guide Mounting accessories PB5008 PB50085 PB50007 PB5000 PB5005 PB5000 PB5007 PB50075 Enclosure dimensions (mm) Height Width N of doors Metallic mounting plates Insulating mounting plates Plain Telequick Polyester Bakelite Modular distribution chassis Internal door Page 6 Page 65 Page 6 Page 7 Page NSYPMM55 NSYPMR55 NSYPMA55 NSYPMB NSYPAPLA NSYPMM75 NSYPMR57 NSYPMA75 NSYPMB NSYPAPLA NSYPMM50 NSYPMR55 NSYPMA50 NSYPMB NSYPAPLA NSYPMM55 NSYPMR55 NSYPMA55 NSYPMB55 NSYPAPLA NSYPMM75 NSYPMR57 NSYPMA75 NSYPMB75 NSYPAPLA NSYPMM75 NSYPMR75 NSYPMA75 NSYPMB75 NSYDLP76 NSYDLP57 NSYPAPLA NSYPMM77 NSYPMR77 NSYPMA77 NSYPMB77 NSYDLP NSYDLP99 NSYPAPLA NSYPMM70 NSYPMR75 NSYPMA70 NSYPMB70 NSYDLP76 NSYDLP57 NSYPAPLA NSYPMM7 NSYPMR75 NSYDLP76 NSYDLP57 NSYPAPLA75 NSYPMA7 NSYPMB7 NSYPMR77 NSYDLP NSYDLP99 NSYPAPLA NSYPMM05 NSYPMR05 NSYPMA05 NSYPMB05 NSYDLP NSYDLP NSYPAPLA NSYPMM07 NSYPMR07 NSYPMA07 NSYPMB07 NSYDLP98 NSYDLP65 NSYPAPLA NSYPMM00 NSYPMR05 NSYPMA00 NSYPMB00 NSYDLP NSYDLP NSYPAPLA NSYPMM0 NSYPMR05 NSYDLP NSYDLP NSYPAPLA05 NSYPMA0 NSYPMB0 NSYPMR07 NSYDLP98 NSYDLP65 NSYPAPLA NSYPMM5 NSYPMR5 NSYPMA5 NSYPMB5 NSYDLP NSYDLPP NSYPAPLA NSYPMM7 NSYPMR7 NSYPMA7 NSYPMB7 NSYDLP NSYDLP98P NSYPAPLA NSYPMM0 NSYPMR5 NSYPMA0 NSYPMB0 NSYDLP NSYPLDP NSYPAPLA NSYPMM NSYPMR5 NSYDLP NSYDLPP NSYPAPLA5 NSYPMA NSYPMB NSYPMR7 NSYDLP NSYDLP98P NSYPAPLA NSYPMM55 NSYPMR55 - NSYPMB55 NSYDLP7 NSYDLP5 NSYPAPLA NSYPMM57 NSYPMR57 - NSYPMB57 NSYDLP97 NSYDLP6 NSYPAPLA NSYPMM50 NSYPMR55 - NSYPMB50 NSYDLP7 NSYDLP5 NSYPAPLA NSYPMM5 NSYPMR55 NSYPMR57 - NSYPMB5 NSYDLP7 NSYDLP97 NSYDLP5 NSYDLP6 NSYPAPLA55 NSYPAPLA57 VDI accessories Enclosure dimensions (mm) 9 fixed chassis Number of U 9 swing chassis Number of U Height Width Page 7 Page NSYBRF8PLA 8 NSYBRP7PLA NSYBRFPLA NSYSPLA75 NSYBRPPLA NSYSPLA NSYBRF7PLA NSYSPLA00 7 NSYBRP6PLA NSYSPLA NSYBRFPLA NSYSPLA5 NSYBRP0PLA NSYSPLA NSYBRF6PLA NSYSPLA50 6 NSYBRP5PLA NSYSPLA

52 Thalassa PLA Polyester floor-standing enclosures Accessory selection guide Main accessories DB006 PB5009 PB5009 PB5009 PB5009 PB50086 PB50087 PB50088 PB50089 PB50090 PB50076 PB50077 PB50078 PB50079 PB50080 PB5008 DB006 PB5008 PB5008 Enclosure dimensions (mm) N plinth Height 60 mm H plinth Height 900 mm Floor-fixing frame Canopy Cable-entry plate Width Depth Page 5 Page 55 Page 58 Page NSYZNPLA5 NSYZHPLA5 NSYMFPLAZ5 NSYTJPLA5 NSYECPLAZ NSYZNPLA5 NSYZHPLA5 NSYMFPLAZ5 NSYTJPLA5 NSYECPLAZ NSYZNPLA7 NSYZHPLA7 NSYMFPLAZ7 NSYTJPLA7 NSYECPLAZ NSYZNPLA7 NSYZHPLA7 NSYMFPLAZ7 NSYTJPLA7 NSYECPLAZ NSYZNPLA0 NSYZHPLA0 NSYMFPLAZ0 NSYTJPLA0 NSYECPLAZ NSYZNPLA0 NSYZHPLA0 NSYMFPLAZ0 NSYTJPLA0 NSYECPLAZ NSYZNPLA NSYZHPLA NSYMFPLAZ NSYTJPLA NSYECPLAZ 50 0 NSYZNPLA NSYZHPLA NSYMFPLAZ NSYTJPLA NSYECPLAZ Step slides Uprights and mounting rails Door retainer Page 66 Page 68 Page 60 Door switch Insert Document pocket VDI accessories and fixings Page 6 Page 68 Coupling Kit Anti-graffiti paint Handles and inserts Wall-fixing lug Page 5 Page 70 Page 6 Page 58 5

53 Composition accessories Thalassa PLA Coupling accessories Horizontal coupling kits F or coupling enclosures side by side. Coupling frame kit: made up of a coupling kit and the fixings required for installation. IP 55 at the coupling point. Trim kit: made up of frames for aesthetic fitting of the coupled enclosures. For enclosure References of coupling frame kit for enclosure (mm) Height (mm) Depth 0 Depth NSYMUPLA5 NSYMUPLA7 NSYMUPLA0 NSYMUPLA NSYMUPLA5 NSYMUPLA5 NSYMUPLA7 NSYMUPLA0 NSYMUPLA NSYMUPLA5 For enclosure References of trim kit for enclosure (mm) Depth 0 Without canopy With canopy DB006 Trim frames 5 NSYSUPLA NSYSUPLAT Depth 0 NSYSUPLA NSYSUPLAT Coupling frames

54 Thalassa PLA Composition accessories Coupling accessories Vertical coupling kit For coupling enclosures on top of one another. Kit made up of.5 m of adhesive seal and the fixings required for mounting. IP 55 at the coupling point. Description Vertical coupling kit Reference NSYUVPLA DB006 Specific PB5067 Configured Enhanced depth enclosure After industrial machining, the frames of the standard enclosures are coupled in the factory to obtain enhaced depth floor-standing enclosures. possible depths: 575, 675 and 775 mm. The internal volume of the standard enclosures remains unaffected. Possible for the enclosure versions, in particular for 9" applications with widths of 750 and 50 mm. IP in the version with ventilated canopy, IP 5 for the other versions. Roof made from polyester reinforced with fibreglass, for dimensions: mm, mm, mm and mm. A rear door can be installed in the coupled enclosures. Option of installing sets of step slides (at the front and at the rear). Supply or installation in the enclosures of a 9" chassis with side trim plate installed on the step slides: 9 U, height 000 mm U, height 50 mm 5 U, height 500 mm Configured offer for PLA and PLAZ versions with depth 575 and 775 mm. 5

55 Thalassa PLA Composition accessories Base accessories PB50080 N Plinth height 60 mm Designed to be installed under the closed-bottom enclosures (version PLA or PLAT). Polyester reinforced with fibreglass, moulded by hot compression, RAL 70 grey. B DB /0 B+0 60 For floor-standing enclosure (mm) Width (B) Depth Reference NSYZNPLA NSYZNPLA NSYZNPLA NSYZNPLA NSYZNPLA NSYZNPLA NSYZNPLA NSYZNPLA 65 B Buriable H Plinth height 900 mm PB5068 C 05 Designed to be installed under the open-bottom enclosures (version PLAZ or PLAZT). Polyester reinforced with fibreglass, moulded by hot compression, RAL 70 grey. Front panel with a height of 70 mm, retractable, providing easy access to the inside. Fixed front panel with a height of 05 mm, corresponding to the finished floor height area. The height above the floor after building-in varies between and 500 mm. A metal rail helps to fix the entry cables. Lateral uprights with pre-knock-out auxiliary output with Pg 6 (8 mm). A pre-knock-out area is provided at the bottom of the lateral uprights for cable entry, if necessary. Delivered with the fixings required for installation. PB5008 DB0066 C-0 B+5 For floor-standing enclosure (mm) Width (B) Depth (C) Reference NSYZHPLA NSYZHPLA NSYZHPLA NSYZHPLA NSYZHPLA NSYZHPLA NSYZHPLA NSYZHPLA Specific Optional removable top front plate, with two double-bar locks. 5

56 Thalassa PLA Composition accessories Base accessories C B Connectors between plinths Designed to allow the adaptation of a closed-bottom enclosure + N plinth on a H-type partially buried plinth. Composition: parts for adapting the centre-to-centre distances. B+0 00/0 60 For floor-standing enclosure (mm) Description Reference Depth 0 0 Linking parts for N plinth on 0-mm H plinth Linking parts for N plinth on 0-mm H plinth NSYAZPLA NSYAZPLA D /60 70/70 D / DB0067 C-0 B+5 DB0069 C-60 B-60 DB0060 DB0068 Floor-standing frame Frame for direct fixing on the floor for installing open-bottom enclosures (version PLAZ or PLAZT). Material: passivated zinc-coated steel. For floor-standing enclosure (mm) Reference Width (B) Depth (C) NSYMFPLAZ NSYMFPLAZ NSYMFPLAZ NSYMFPLAZ NSYMFPLAZ NSYMFPLAZ NSYMFPLAZ NSYMFPLAZ Floor-fixing studs Set of four threaded parts and fixings, for fixing the enclosures on concrete plinths. Description Fixing studs Reference NSYFSPLAZ 55

57 Thalassa PLA Composition accessories Base accessories ZA plinths for PLA enclosure (version PLA and PLAT) Designed to support and raise the closed-bottom versions of PLA enclosures, in other words, references NSYPLAxx or NSYPLATxx: Polyester material reinforced with fibreglass, moulded by hot compression. Guarantees total insulation according to IEC 69-. Ensures a degree of protection of IP and impact resistance of IK 0. Plinth height of mm; stackable to obtain a 00-mm plinth. Four floor-attachment points; the symmetry of the parts prevents incorrect assembly. PB5078 PB5079 The frontal parts of the plinth (front and rear) have two stainless-steel screws protected by a plastic cap; these screws, which can be accessed from the outside, make it possible (using an Allen key) to open and remove the frontal parts for easier cable installation. In stacked position, the bottom plinth can be partially buried. It is provided with one or two reinforcement cross-rails, adjustable to adapt to the position of the cables. The reference of the plinth contains all the accessories required for attaching the enclosure to the plinth and for stacking two plinths. For floor-standing enclosure Plinth Cable-gland area Height Width Depth Reference Height Width Depth Reference Width Depth 500 to NSYPLA(T)x NSYZA to NSYPLA(T)x NSYZA to NSYPLA(T)x NSYZA to NSYPLA(T)x 50 NSYZA to NSYPLA(T)x NSYZA to NSYPLA(T)x NSYZA to NSYPLA(T)x NSYZA to NSYPLA(T)x 50 NSYZA 0 05 PB5070 Cable supporting cross-rail The lateral sides of the plinth are provided with bosses for attaching cross-rails with cut-out profiles, for supporting cables. The reference of the cross-rail includes all the elements required for assembly. For plinth Cross-rail NSYZA5 NSYZA5 NSYAC0 NSYZA7 NSYZA7 NSYAC560 NSYZA0 NSYZA0 NSYAC80 NSYZA NSYZA NSYAC080 Kit for IP 5 Makes it possible to obtain IP 5 for the plinth and the plinth-enclosure connection Ref. NSYAEPZA. Feet for partially buried installation Allows the partially buried installation of plinths before completion of the floor. The plinths are attached by four feet with a standard length of 750 mm. Possibility of horizontal adjustment of the plinth. The kit is made up of four feet and fixings, ref. NSYAEBFZ. PB507 56

58 Thalassa PLA Composition accessories Base accessories ZZ plinths for PLA enclosure (version PLAZ and PLAZT) Designed to support and raise the open-bottom versions of PLA enclosures, in other words, references NSYPLAZ or NSYPLAZT: Polyester material reinforced with fibreglass, moulded by hot compression. Guarantees total insulation according to IEC 69-. Ensures a degree of protection of IP and impact resistance of IK 0. PB5075 PB5077 PB507 PB507 PB507 The offer consists of two plinths, with heights of mm and 500 mm. Four floor-attachment points; the symmetry of the parts prevents incorrect assembly. The frontal parts (front and rear) are removed from the inside. Removing them makes it easier to install the cables. The 500-mm plinth can be partially buried. It is provided with one or two reinforcement cross-rails, adjustable to adapt to the position of the cables. The reference of the plinth contains all the accessories required for attaching the enclosure to the plinth. For floor-standing enclosure Plinth Cable-gland area Height Width Depth Reference Height Width Depth Reference Width Depth 500 to NSYPLAZ(T)x NSYZZ to NSYPLAZ(T)x NSYZZ to NSYPLAZ(T)x NSYZZ to NSYPLAZ(T)x 85 0 NSYZZ to NSYPLAZ(T)x NSYZZ to NSYPLAZ(T)x NSYZZ to NSYPLAZ(T)x NSYZZ to NSYPLAZ(T)x 85 0 NSYZZ to NSYPLAZ(T)x NSYZZ to NSYPLAZ(T)x NSYZZ to NSYPLAZ(T)x NSYZZ to NSYPLAZ(T)x NSYZZ to NSYPLAZ(T)x NSYZZ to NSYPLAZ(T)x NSYZZ to NSYPLAZ(T)x NSYZZ to NSYPLAZ(T)x NSYZZ Cable supporting cross-rail The lateral sides of the plinths are provided with bosses for attaching cross-rails with cut-out profiles, for supporting cables. The reference of the cross-rail includes all the elements required for assembly. For plinth Cross-rail NSYZZ5 NSYZZ5 NSYZZ55 NSYZZ55 NSYAC60 NSYZZ7 NSYZZ7 NSYZZ57 NSYZZ57 NSYAC600 NSYZZ0 NSYZZ0 NSYZZ50 NSYZZ50 NSYAC80 NSYZZ NSYZZ NSYZZ5 NSYZZ5 NSYAC0 Outside opening kit The -mm front part of the - and 500-mm plinths can be opened from the outside, after installing a kit made up of two locks with double-bar insert, ref. NSYAELZ. Feet for partially buried installation Allows the partially buried installation of plinths before completion of the floor. The plinths are attached by four feet with a standard length of 750 mm. Possibility of horizontal adjustment of the plinth. The reference includes a kit made up of four feet and fixings, ref. NSYAEBFZ. 57

59 Thalassa PLA Composition accessories Top-mounting accessories Fixing accessories PB5069 Canopy Polyester material reinforced with fibreglass, moulded by hot compression, selfextinguishing, RAL 70 grey. It can be installed in all enclosure models. High resistance to impacts, temperature and bad weather. Delivered with the fixings required for installation. Increases the height (A) of the enclosure by 8 mm, without modifying its width or depth. Essential for outdoor use. DB006 C= 0/0 A+8 For enclosure (mm) Reference Width Depth (C) NSYTJPLA NSYTJPLA NSYTJPLA NSYTJPLA NSYTJPLA NSYTJPLA NSYTJPLA NSYTJPLA PB50055 Grille for IP 5 instead of IP For enclosure versions PLAT and PLAZT. It is installed from the inside in the upper ventilation opening. Delivered with G M standard synthetic filter, see ClimaSys section. grille for 500 and 750 mm wide enclosures, grilles for 000 and 50 mm wide enclosures. Prevents the entry of dust and provides the enclosure with IP 5X protection at the top. Maintains the possibility of ventilation. Description Outlet grille Reference NSYCAG5LPF PB5009 Wall-fixing lugs Fixing on the sides by or 6 lugs in horizontal position (6 lugs for enclosures with height 000 mm). Drilling positions and marks inside the side panels. Passivated zinc-coated material. Maximum acceptable load: 80 kg. Set of 6 lugs and fixings. 0 mm fixing plane on the rear of the enclosure plane. Description Wall-fixing lugs Reference NSYFMPLA Specific Available stainless-steel wall-fixing lugs. DB006EN A-75 () B+5 () For enclosures with height 000 mm, extra lug at the centre of the A-75 side. 58

60 Thalassa PLA Composition accessories Cable-entry accessories PB5008 Cable-entry plate Designed to be installed inside the enclosures with open bottom part (version PLAZ or PLAZT). Polyester material reinforced with fibreglass, thickness mm. Easy drilling in specific customised version. Delivered with the fixings required for installation. Incompatibility with: adapter plates, step slides, internal door and chassis for modular distribution. For enclosure (mm) Width (B) Depth (C) Reference NSYECPLAZ NSYECPLAZ NSYECPLAZ NSYECPLAZ NSYECPLAZ NSYECPLAZ NSYECPLAZ NSYECPLAZ Cable-entry plate (-door enclosure) DB006 C 0 C 78 0 B 0 5 C 78 Cable-entry plate (-door enclosure) DB B

61 Thalassa PLA Composition accessories Door and door accessories Internal door PB50075 PB50750 Aluminium door, RAL 70 grey. Designed for direct installation in enclosures with sealed bottom part. In the enclosures with the bottom part open, installation can be performed by ordering the necessary adapter plates, ref. NSYPTZ. depthwise mounting positions () according to the chosen M8 impressions, on the top and bottom parts of the enclosure, for fixing. Lock with 5-mm double-bar inserts. Delivered with M8 brass inserts and fixings. Incompatibility with: modular distribution chassis, 9" chassis, cable-entry plate and door retainer, ref. NSYRETPLAU. DB006 C 5 () 0 () C 0 () Two positions for depthwise installation. () The nd position moves the position of the internal door back by 5 mm. DB0065 E D For enclosure (mm) Internal door dimensions Reference Height Width D E Weight (kg) NSYPAPLA NSYPAPLA NSYPAPLA ( 98). (.6) NSYPAPLA55 NSYPAPLA (98 68).8 (.6.) NSYPAPLA NSYPAPLA NSYPAPLA ( 98). (.) NSYPAPLA75 NSYPAPLA (98 68) 5. (..) NSYPAPLA NSYPAPLA NSYPAPLA ( 98) 5. (.8) NSYPAPLA05 NSYPAPLA (98 68) 6.9 (.8.) NSYPAPLA NSYPAPLA NSYPAPLA ( 98) 6.8 (.) NSYPAPLA5 NSYPAPLA (98 68) 8. (. 5) NSYPAPLA NSYPAPLA NSYPAPLA ( 98) 8 ( ) NSYPAPLA55 NSYPAPLA (98 68) 0 ( 6) Door retainer PB50078 NSYRETPLA PB50079 NSYRETPLAU Designed to adapt directly to the enclosure. models available according to the type of enclosure: model opening to 0 for enclosure versions PLA, PLAZ and PLAT. model with positions, 90 and 0, for all the versions (warning: this solution is incompatible with certain accessories), see below. Can be installed on a door opening to the left or right indistinctly. Material: galvanised steel. Delivered with the fixings required for installation. For enclosure Version PLA, PLAZ, PLAT For all versions Reference NSYRETPLA NSYRETPLAU Note: Ref. NSYRETPLAU is incompatible with internal doors, modular distribution chassis, step slides, adapter plates and cable-entry plates. In the event of incompatibility, use ref. NSYRETPLAZ. 60

62 Thalassa PLA Composition accessories Door and door accessories PB50086 Door switch Supply: switch, fixing bracket and fixings. NC + NO switch. Incompatible with the rear door and modular distribution chassis. Description Door switch Reference NSYSNLPLA Protection and support screen Protective screen made from transparent polycarbonate, protecting access to the switchgear of small enclosures. The screen is fixed using accessory, ref. NSYSPTR77, to be ordered separately. The screens and fixing accessories are to be ordered in multiples of 5. DB0066 PB507 A - 58 C C - 70 A - For enclosure (mm) Reference Width (A) Height (C) NSYPPTR NSYPPTR NSYPPTR NSYPPTR77 6

63 Thalassa PLA Composition accessories Locking system Locks with escutcheon and without handle Standard supply for the enclosures with sealed top and bottom parts (PLA version). With 5 mm double-bar insert. PA6 material charged with fibreglass. RAL 70 grey. Fire resistance: 650 C. Resistance to external mechanical impacts: IK 0. Insert breakage torque: 5 dan. Options of changing the form inserts (supplied with the required operating key) Description Reference 7 mm square insert NSYTC7CRN 8 mm square insert NSYTC8CRN 6.5 mm triangular insert NSYTT6CRN 8 mm triangular insert NSYTT8CRN 5 mm double-bar insert NSYTDB5PLA DB0067 Padlocking device Padlocking accessory, preventing access to the lock-control insert. Opening diameter: mm. PB507 Description Padlocking device Reference NSYBCPLA NSYBCPLA DB0068 Options of changing for a handle lock Option of changing the escutcheon and the insert for a handle lock, ref. NSYEBMPLA, delivered without barrel or insert block. The insert or barrel are to be chosen from the option table on the next page. NSYEBMPLA 6

64 Thalassa PLA Composition accessories Locking system Lock with handle Ergonomic locking system with pivoting handle installed as standard on enclosures with ventilated canopy and/or open bottom part (versions PLAT, PLAZ and PLAZT), with a 5 mm double-bar insert block. Material: PA6 charged with 0% fibreglass. RAL 70 grey. Fire resistance: 650 C. Resistance to external mechanical impacts: IK 0. Options of changing the form-insert blocks (supplied with the required operating key) DB0069 Description Block, 6 mm square insert Block, 7 mm square insert Block, 8 mm square insert Block, 6.5 mm triangular insert Block, 8 mm triangular insert Push-button Double bar Reference NSYINS6 NSYINS7 NSYINS8 NSYINT6 NSYINT8 NSYTSPLA NSYINDB5 Options of changing for blocks with cylindrical barrels Block with form insert. Block with cylindrical barrel. Block with semi-cylindrical barrel. Type of key Reference 05 E key NSYIN05E E key NSYINE 55 key NSYIN55 E key NSYINE E key NSYINE A key NSYINA A key NSYINA A key NSYINA A key NSYINA Type of key Reference 5 E key NSYIN5E A key NSYINA E key NSYINE A key NSYINA A key NSYINA E key NSYINE E key NSYINE EDF 00 key NSYINF0 EDF 00 key NSYINF0 Options of changing for blocks with semi-cylindrical barrels Description Reference E key NSYINE DIN adapter NSYINDIN JIS key NSYINKJIS Reinforced key NSYINKR FAC key NSYINKFAC PB507 DB00650 Options of changing the handle Changing the handle for a handle including a padlocking device ( 0 mm) allowing the handle to be locked. Option of changing the handle lock for a lock with an escutcheon and without handle, delivered without insert. The insert is to be chosen from the option table on the previous page: NSYCBCMPLA NSYEBPLA Description Padlocking handle Escutcheon without handle, without insert Reference NSYCBCMPLA NSYEBPLA 6

65 Thalassa PLA Mounting accessories Installation accessories Metallic mounting plate and insulating mounting plate PB507 PB5075 Plain mounting plate Galvanised sheet-steel mounting plate. Direct installation on M8 inserts at the rear of the enclosure or on step slides for depth adjustment (see page 66). The enclosures with height of 000 mm have intermediate impressions for installing mounting plates of a lesser height (M8 inserts, ref. NSYTEX8, to be ordered separately). In the -door enclosures, it is possible to install complete mounting plate or individual mounting plates. Maximum acceptable load: 50 kg/m. Thickness:.5 mm. Insulating mounting plate Bakelite mounting plate, RAL 9005 black. Polyester mounting plate, RAL 705. Maximum acceptable load: 50 kg/m. Thickness: mm for the 55 and 75 plates, 5 mm for the other plates. For enclosure (mm) Height (A) Width (B) Plain Mounting plate references Bakelite Insulating Polyester Surf. (dm ) H (mm) NSYPMM55 NSYPMB55 NSYPMA NSYPMM75 NSYPMB75 NSYPMA NSYPMM50 NSYPMB50 NSYPMA NSYPMM55 NSYPMB55 NSYPMA55 NSYPMM75 NSYPMB75 NSYPMA NSYPMM75 NSYPMB75 NSYPMA NSYPMM77 NSYPMB77 NSYPMA NSYPMM70 NSYPMB70 NSYPMA NSYPMM7 NSYPMB7 NSYPMA NSYPMM05 NSYPMB05 NSYPMA NSYPMM07 NSYPMB07 NSYPMA NSYPMM00 NSYPMB00 NSYPMA NSYPMM0 NSYPMB0 NSYPMA NSYPMM5 NSYPMB5 NSYPMA NSYPMM7 NSYPMB7 NSYPMA NSYPMM0 NSYPMB0 NSYPMA NSYPMM NSYPMB NSYPMA NSYPMM55 NSYPMB NSYPMM57 NSYPMB NSYPMM50 NSYPMB NSYPMM5 NSYPMB e A-0 () A H DB0065EN B-50 B B-5 H.5 () () Reinforcing fold for steel mounting plate with heights and widths 000 mm. () A-5 for references NSYPMM00 to NSYPMM5, A-0 for the polyester mounting plate, ref. NSYPMA. Note: The diagrams above relate to the metal mounting plates. The mounting plates made from insulating material only have or 8 main fixing points and the external dimensions of the diagrams. 6

66 Thalassa PLA Mounting accessories Installation accessories PB5076 Telequick mounting plate It allows any switchgear to be mounted on the same plane without drilling or tapping. Grille made from galvanised sheet steel, with 6 mm drill holes, with a step of 5 0 mm, for direct installation, with clip nuts, of all the devices with fixing at, or points, by screws with diameters of,, 5 or 6 mm. Direct installation on M8 inserts at the rear of the enclosure or on step slides for depth adjustment (see page 66). The enclosures with height of 000 mm have intermediate impressions for installing mounting plates of a lesser height (M8 inserts, ref. NSYTEX8, to be ordered separately). Maximum acceptable load: 50 kg/m. DB0065 E+0 E D D+6 5 For enclosure (mm) Dimensions (mm) Reference Height Width E D Surface (dm ) NSYPMR NSYPMR NSYPMR ( 5.) NSYPMR NSYPMR (5..6) NSYPMR NSYPMR NSYPMR ( 5.5) NSYPMR NSYPMR (5.5 5.) NSYPMR NSYPMR NSYPMR ( 5.7) NSYPMR NSYPMR ( ) NSYPMR NSYPMR NSYPMR ( 5.9) NSYPMR NSYPMR (5.9 7) NSYPMR NSYPMR NSYPMR ( 56.) NSYPMR55 NSYPMR ( ) 65

67 Thalassa PLA Mounting accessories Installation accessories PB50076 Step slides Set of step slides with brackets allowing continuous depth adjustment of the mounting plate, with a pitch of 5 mm. Designed for direct installation in the enclosures with sealed bottom part (versions PLA or PLAT). In the enclosures with open bottom part (versions PLAZ or PLAZT), installation is made possible by adding the relevant adapter plates (see tables below and description on the next page). Material: bracket with steel M8 stud on aluminium rail. Fixing on the top and bottom parts of the enclosure by means of M8 inserts and screws (supplied). Incompatibility with: internal door, modular distribution chassis, 9" chassis, cableentry plate and door retainer, ref. NSYRETPLAU. For enclosure Reference Depth (mm) N of doors Step slides Adapter plates 0 NSYDPLA NSYPTZ 0 NSYDPLA NSYPTZ 0 NSYDPLA NSYPTZP 0 NSYDPLA NSYPTZP Installation of step slide ref. NSYDPLA 5 50/50 6 () PB5077 PB5078 NSYDPLA NSYDPLA and NSYPTZ DB0065 DB0065 () 57 mm with one transparent door. Installation of step slide ref. NSYDPLA, with adapter plate ref. NSYPTZ 5 50/50 6() () 57 mm with one transparent door. 66

68 Thalassa PLA Mounting accessories Installation accessories PB5079 NSYPTZ PB5080 NSYPTZ P Adapter plates The enclosures with open bottom part (versions PLAZ and PLAZT) require a set of adapter plates for mounting: an internal door step slides modular chassis and 9" chassis Material: galvanised steel. Fixing on the bottom part of the enclosure by means of M8 inserts and screws (supplied). Depth (mm) For enclosure N of doors Reference 0 NSYPTZ 0 NSYPTZ 0 NSYPTZP 0 NSYPTZP Additional support Set of additional brackets, to be slid into the step slides, for the installation of an additional mounting plate. Description Additional support Reference NSYEDPLA PB506 B - 00 Side mounting plates Polyester mounting plates fixed to the sides of the enclosure for additional installations. Installation on the M8 bosses by adding inserts, ref. NSYTEX References by unit. Order by multiples of units (,, 6, etc.). A - 00 PB508 DB00655EN For enclosure (mm) Height (A) Depth (B) Reference NSYPMLA NSYPMLA NSYPMLA NSYPMLA NSYPMLA NSYPMLA NSYPMLA 50 0 NSYPMLA Partial plain mounting plate H Galvanised sheet-steel mounting plate. Direct fixing on the uprights, with the notched sliding nuts or pivoting nuts, see common accessories section. Maximum acceptable load: 50 kg/m. PB508 B- For enclosure Mounting plate Fixing centre-to-centre distance Width B (mm) height H (mm) Vertical Horizontal Reference NSYSPMP NSYSPMP NSYSPMP000 67

69 Thalassa PLA Mounting accessories Installation accessories 5 A 5 A PB508 5 PB508 Technical uprights Supports for fixing rails, perforated grilles and plain partial mounting plates. Use the suitable fixings and accessories shown in the common accessory section. Material: steel, mm thick. Batch of pieces. Fixing at the rear on the M8 inserts or on the step slides. For enclosure Height (mm) References Dimensions 750 NSYTVR NSYTVR NSYTVR NSYTVR5 75 Note: Enclosures with widths of 000 and 50 allow the installation of uprights to integrate mounting plates of 500 mm or of 500 and 750 mm. 5 9 DB PB50077 Rails Symmetric or asymmetric DIN rails for mounting on the technical uprights, ref. NSYTVR. Fixings and accessories: see common accessories. References by unit. Order by multiples of 0 units (0, 0, 0, etc.). For installation in DIN rail references enclosures with width (B) (mm) Symmetrical 5 5 Asymmetrical 500 NSYCSPLA50 NSYCAPLA NSYCSPLA75 NSYCAPLA () NSYCSPLA00 NSYCAPLA00 () Enclosures with a width of 000 mm can accommodate mounting plates with rail types NSYCSPLA50 or NSYCAPLA50. PB50087 M8 inserts To be placed in the bosses moulded on the doors, uprights, rear panels and bottom and top parts, for fixing accessories and assorted devices. References by unit. Order by multiples of 8 units (8, 6,, etc.). Description M8 inserts Reference NSYTEX8 68

70 Thalassa PLA Mounting accessories Equipment support accessories PB Support plate Designed to support assorted equipment or simply to install a separation. It is installed directly on the bottom part of the enclosure. For the installation of one or several support plates, use sets of uprights suitable for the height (to be ordered separately). These uprights offer the option of adjusting the height with a step of 50 mm. Galvanised-steel material. Delivered with the fixings required for installation. In the -door enclosures, the installation of the plate or the uprights requires the prior installation of an intermediate support, ref. NSYSBPLA, presented below. C 80 DB B 8 For enclosure (mm) Depth (C) Width (B) Max. load Plate Reference kg NSYBANPLA kg NSYBANPLA kg NSYBANPLA kg NSYBANPLA7 For enclosure Height (mm) N of adjustments Upright Reference NSYSPLA NSYSPLA00 50 NSYSPLA NSYSPLA50 00 NSYSPLA00 NSYSPLA75 NSYSPLA00 NSYSPLA5 DB00658 NSYSPLA50 DB00659 PB5088 PB5086 Intermediate support in the -door enclosures Required accessory for installing support plates, ref. NSYBANPLA or uprights, ref. NSYSPLA in the -door enclosures. Description Intermediate support Reference NSYSBPLA 69

71 Thalassa PLA Accessories Renovation and anti-graffiti paint -component paint system, specially formulated for polyester enclosures. Renews enclosures and allows easy removal of graffiti. Paint composed of: base (80%) and hardener (0%). RAL 70 grey. references available: kg: 800 g tin of base paint g tin of hardener 5 kg: kg tin of base paint kg tin of hardener Coverage kg = 5 m 5 kg = 5 m Solvent in 500 g bottles to be used as a paint thinner or to clean brushes. PB5009 Description Anti-graffiti paint kg Anti-graffiti paint 5 kg Anti-graffiti paint solvent 500 g Reference NSYAUPG NSYAUPG5 NSYAUPGS PB5007 *Discover our ClimaSys thermal management offer Ventilation accessories. Filters. Regulation accessories. PB

72 Thalassa PLA Power distribution accessories Modular distribution accessories Modular distribution chassis Chassis for modular switchgear, installed directly in the sealed enclosures (PLA version). For installation in enclosures with open bottom part (PLAZ version) it is necessary to use a set of adapter plates (ref. NSYPTZ ). Chassis made up of cover plates, made from self-extinguishing insulating material, RAL 70 grey, on a rigid galvanised-steel structure. Quick installation without fixings. Distance between rail and front panel with adjustable depth from 0 to 85 mm. System for identifying electrical circuits supplied. Neutral/earth strip: 6 mm 5 6 mm included in the standard offer. Incompatibility with: cable-entry plate, internal door, door switch and door retainer (ref. NSYRETPLAU). PB5087 (500) (500) (500) (750) (500) (000) (500) (50) NSYDLP76 NSYDLP NSYDLP NSYDLP7 PB5088 Details of the depth adjustment. (500) (750) (500) (000) (500) (50) (500) (500) NSYDLP57 NSYDLP NSYDLPP NSYDLP5 (750) (500) (750) (750) (750) (000) (750) (50) NSYDLP NSYDLP98 NSYDLP NSYDLP97 (750) (500) (750) (750) (750) (000) (750) (50) DB00660 NSYDLP99 NSYDLP65 NSYDLP98P NSYDLP6 7

73 Thalassa PLA Power distribution accessories Modular distribution accessories Row distribution For enclosures (mm) Rows for module N of doors Reference N of rows Number of Height Width Number 8-mm modules Number of plates NSYDLP NSYDLP NSYDLP NSYDLP NSYDLP NSYDLP NSYDLP76 NSYDLP NSYDLP57 NSYDLP NSYDLP NSYDLP NSYDLP NSYDLP NSYDLP NSYDLP NSYDLP NSYDLP NSYDLP NSYDLP NSYDLP NSYDLPP NSYDLP NSYDLP98P NSYDLP NSYDLPP NSYDLP NSYDLP NSYDLPP NSYDLP98P NSYDLP NSYDLP NSYDLP NSYDLP NSYDLP NSYDLP NSYDLP7 NSYDLP NSYDLP5 NSYDLP

74 Thalassa PLA Power distribution accessories Modular distribution accessories Dimensions Min : C /67() PB5089 Detail from front-panel mounting PB5090 DB0066 () Detail from the circuit-marking system. () Dimensions of or 67 mm or a pitch of 5 mm, according to the M8 boss chosen for the installation. See details in the enlarged image on the right. In the enclosures with glazed doors, the dimensions are reduced by 5 mm. () C = Depth of the enclosure. Plain cover plate Self-extinguishing insulating material, RAL 70 grey, for non-modular switchgear protection. Nominal height: 50 mm. Order by multiples of (,, 6...). PB509 For enclosure width (mm) Dimensions (mm) Height Width Reference NSYCTL500DLP NSYCTL750DLP DB /65 Plain mounting plate Plate for fixing non-modular devices. Material: galvanised steel, mm thick. Depth-adjustable fixing on the supports from 0 to 85 mm. Nominal height: 50 mm or 00 mm. Order by multiples of (,, 6...). PB509 9/98 For enclosure width (mm) Dimensions (mm) Height Width Reference NSYPMP500DLP NSYPMP750DLP NSYPMP500DLP NSYPMP750DLP DB0066 6/6 0 5º 7

75 Thalassa PLA 9" accessories 9 chassis Very sturdy 9 metal chassis, designed for installation in enclosures with a width of 750 and 50 mm. In the 50 mm enclosure, the chassis is installed in the 750 mm part with an intermediate support, ref. NSYSBPLA. These chassis are available in versions: fixed and swing. These chassis can be used as partial mounting plates in enclosures with higherthan-nominal height. Incompatible with the internal doors and the step slides. 9 fixed chassis Fixed chassis made up of uprights with fixings. For heights from 750 to 500 mm, the installation requires ordering batch of matching uprights. If a chassis is installed in an enclosure with a greater height, it is necessary to use the suitable uprights for the size of the enclosure. Material: sheet steel, thickness 0 / 0 mm, RAL 70 grey epoxy-polyester paint. Maximum load: kg per U. PB5008 For enclosure (mm) Reference Height Width Number of U 9 fixed chassis Batch of uprights Enclosure with 9 fixed chassis NSYBRF8PLA NSYBRFPLA NSYSPLA NSYBRF7PLA NSYSPLA NSYBRFPLA NSYSPLA NSYBRF6PLA NSYSPLA50 9 swing chassis Swing chassis opening to 0 with 5 mm double-bar key lock. For heights from 750 to 500 mm, the installation requires ordering batch of matching uprights. If a chassis is installed in an enclosure with a greater height, it is necessary to use the suitable uprights for the size of the enclosure. Material: sheet steel, thickness 0 / 0 mm, RAL 70 grey epoxy-polyester paint. Maximum load: kg per U. PB50085 For enclosure (mm) Reference Height Width Number of U 9 swing chassis Batch of uprights Enclosure with 9 swing chassis NSYBRP7PLA NSYBRPPLA NSYSPLA NSYBRP6PLA NSYSPLA NSYBRP0PLA NSYSPLA NSYBRP5PLA NSYSPLA50 7

Serious about Service

Serious about Service Serious about Service Stainless steel enclosures IP66 Features and benefits Features: IP66 certified Grades 304, 304L and 316L available Monobloc symmetrical enclosure Scotch Brite mechanical polished

More information

*Discover our other ranges: Select your range of Spacial steel wall-mounting enclosures. Spacial S3DC. Spacial S3X page 5/4. Thalassa PLM page 6/12.

*Discover our other ranges: Select your range of Spacial steel wall-mounting enclosures. Spacial S3DC. Spacial S3X page 5/4. Thalassa PLM page 6/12. Spacial SDC Select your range of Spacial steel wall-mounting enclosures SDC You need an efficient, sealed multipurpose and aesthetic enclosure for an indoor industrial facility. Our solution: the Spacial

More information

Human-Machine Interface

Human-Machine Interface Spacial SD SDX HumanMachine Interface Specific accessories overview PB50033033 PB50121335 Door Page 318 Page 320 Page 321 Locking system Windows PB50099528 Floor PB50120630 Modular consoles PB50121617

More information

Wall-mounting steel enclosures suitable for any CRN and CRNG application

Wall-mounting steel enclosures suitable for any CRN and CRNG application Wall-mounting steel enclosures suitable for any CRN and CRNG application 1 2 3 4 5 6 1 Front rain gutter prevents the entry of water, oil or liquids, ensuring IP66 protection. 10 9 8 7 1/18 2 A complete

More information

Spacial SF for Prisma Plus P system

Spacial SF for Prisma Plus P system The Spacial SF range includes specific enclosure models for installing the Prisma Plus P : functional units and vertical and horizontal busbars The panels are subject to type tests according to standard

More information

BOXES WALL-MOUNTING BOXES AND TERMINAL BOXES

BOXES WALL-MOUNTING BOXES AND TERMINAL BOXES BOXES WALL-MOUNTING BOXES AND TERMINAL BOXES ST WALL-MOUNTING BOXES WITH BLANK DOOR STP WALL-MOUNTING BOXES WITH PLEXI DOOR ST/STP COMPLEMENTARY ACCESSORIES SDV TERMINAL BOXES WITH SCREWED COVER SDF TERMINAL

More information

Compact metal enclosures

Compact metal enclosures Spacial SM Compact metal enclosures Overview Convenience Robustness Comfort Practicality Protection Robustness: Body made as a single piece with welded rear panel. Front part forming a rigid frame with

More information

SINGLE DOOR BOXES. PAINT FINISH ETA standard epoxy polyester powder coating. Enclosure and door: colour RAL 7035 textured finish.

SINGLE DOOR BOXES. PAINT FINISH ETA standard epoxy polyester powder coating. Enclosure and door: colour RAL 7035 textured finish. ST SINGLE DOOR BOXES Enclosure and door manufactured from 1.5 mm thick sheet steel. Mounting plate manufactured from 2.5 mm thick sendzimir sheet steel. Enclosure and door: colour RAL 7035 textured finish.

More information

Steel wall-mounting enclosures

Steel wall-mounting enclosures Steel wallmounting enclosures 8 Universal Enclosures Steel wallmounting enclosures P05 P99 Contents Spacial CRN 50 Introduction Characteristics Selection guide imensions Specific accessories overview Common

More information

Spacial 3D steel enclosure 19"

Spacial 3D steel enclosure 19 19" The Spacial 3D 19" enclosure offer, for electronics and networks, comprises 2 ranges: - 1-body enclosures, depth 400 mm, with fi xed or swing rack. - 2-body enclosures, depths 400 and 500 mm. Technical

More information

Prisma Plus G enclosures IP30, IP31, IP43 enclosures

Prisma Plus G enclosures IP30, IP31, IP43 enclosures Prisma Plus G IP30, IP31, IP43 Prisma Plus G IP30, IP31, IP43 Presentation For safe and upgradeable electrical switchboards > Safety of people and property > Continuity of service > Optimization and upgradeability

More information

MINIPOL. Hot moulded GRP

MINIPOL. Hot moulded GRP MINIPOL Hot moulded GRP MINIPOL System HOT MOULDED CABINETS Grey color RAL 7035 Two door types Plain: allows the mounting of devices in the door. Glazed: Combined with mounting plate, chassis and/or internal

More information

IP65 enclosures orion plus

IP65 enclosures orion plus IP65 enclosures orion plus One system for indoor and outdoor application Sheet steel or glass reinforced polyester - the orion plus enclosures are suited for harshest conditions and can be applied for

More information

ROC. IP66 Polyester Double Isolation Boxes. Certificaciones. Technical features

ROC. IP66 Polyester Double Isolation Boxes. Certificaciones. Technical features ROC IP66 Polyester Double Isolation Boxes Roc watertight boxes are made of reinforced polyester with fiber glass, insulating material that keeps installed switchgear perfectly isolated. With a protection

More information

UCP polyester. UDP polyester. UCP Accessories. UDP Accessories. General Accessories. Mounting plates. Wall mounting brackets. Locks.

UCP polyester. UDP polyester. UCP Accessories. UDP Accessories. General Accessories. Mounting plates. Wall mounting brackets. Locks. 160 POLYESTER ENCLOSURES UCP polyester 164 IP66; NEMA 4, 4X, 12, 13 IK10, IK07 H: 315-1035 W: 215-835 D: 170-300 UDP polyester 170 IP 65, 55; NEMA 4, 4X, 12, 13; IK 10, IK 07 H: 500-1250 W: 500-1250 D:

More information

Thorne and Derrick UK

Thorne and Derrick UK PO OL LY POLYESTER ENCLOSURES YE ES ST TE ER POLYESTER ENCLOSURES PO OL LY YE ES ST TE ER UCP IP66/NEMA 4, 4X, 12, 13 Compact version H: 315-1035 W: 215-835 D: 170-300 188 UDP IP65/IP 55 NEMA 4, 4X, 12,

More information

ACCESSORIES FOR SZE2 CABINETS

ACCESSORIES FOR SZE2 CABINETS ZPAS 143 DOORS Doors Intended for use instead of front solid door or rear panel. Maximum door opening angle: 120 Sheet steel textured powder paint, light grey (RAL 7035), stiffened profiles, brown smoked

More information

DOMINO Series surface mounting IP55

DOMINO Series surface mounting IP55 Series surface mounting IP55 SERIES CONSUMER UNITS SURFACE MOUNTING VERSION - IP55 REFERENCE STANDARDS International standard IEC 60670 (989) and the Modification (994) Part : General requirements for

More information

EQUIPMENT FOR CONNECTION OF A PHOTOVOLTAIC INSTALLATION (UP TO 5 KW)

EQUIPMENT FOR CONNECTION OF A PHOTOVOLTAIC INSTALLATION (UP TO 5 KW) Catalogue photovoltaic installations 2005 EQUIPMENT FOR CONNECTION OF A PHOTOVOLTAIC INSTALLATION (UP TO 5 KW) "POSSIBILITY OF ASSEMBLY FOR BIDIRECTIONAL ELECTRONIC MONOPHASE METER FOR ALL VERSIONS". MODULAR

More information

STX stainless steel boxes

STX stainless steel boxes STX stainless steel boxes Enclosure and door manufactured from AISI 304 stainless steel (AISI 316 on request). Mounting plate manufactured from 2.5mm sendzimir sheet steel. Hinge in stainless steel. Box

More information

Empty enclosures IEC 62208

Empty enclosures IEC 62208 374 www.hensel-electric.de/en in accordance with for customized solutions and individual applications for example for low-voltage switchgear and controlgear assemblies i n accordance with the IEC 61439-series

More information

Product Data For FARNELL

Product Data For FARNELL ae Product Data For FARNELL ae Uniset is / Varioset is ae EL ELECTRONIC KOMBI SYSTEM WALL MOUNTING Pole clamp For reliable, convenient fastening to round or square poles. For pole diameter/size:

More information

POLYMEL polyester monobloc enclosures

POLYMEL polyester monobloc enclosures polyester monobloc enclosures 1 2 3 4 5 6 1 The built-in canopy protects the door and the sealing gasket. 5 Enclosure with a tempered glass transparent door, maintaining the IP66 and IK08 (5J) degrees

More information

Composition accessories Locking system

Composition accessories Locking system - SM Composition accessories Locking system Handle for shape inserts and cylindrical barrels Handle lock allowing the door to be opened: with a single movement. Standard handle for the entire range of

More information

XL Distribution enclosures WORKSHOP SPECIFICATIONS

XL Distribution enclosures WORKSHOP SPECIFICATIONS 800 Distribution enclosures WORKSHOP SPECIFICATIONS With its extensive ranges, the Legrand offer meets your quality standards and provides real freedom and simplicity of installation together with acknowledged

More information

Flush mounting enclosures. Pragma UP

Flush mounting enclosures. Pragma UP Flush mounting enclosures Presentation Flush mounting enclosures The appearance of this enclosure, its mechanical strength and its level of electrical safety make it a product fully suitable for residential

More information

Plexo 3 weatherproof cabinets

Plexo 3 weatherproof cabinets 87045 LIMOGES Cedex Telephone: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Plexo 3 weatherproof cabinets CONTENTS PAGES 1. Description, use.....1 2. Range, equivalence table...1 3. Overall dimensions...2

More information

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES O S O O CABINETS AND ENCLOSURES XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES II With its extensive ranges, the Legrand offer meets your quality standards and

More information

metal and polyester INDUSTRIALenclosures 2016catalogue

metal and polyester INDUSTRIALenclosures 2016catalogue metal and polyester INDUSTRIALenclosures 2016catalogue Quality products IDE reserves the right to alter or modify references or characteristics of any of its products, if needed it by any technical improvement,

More information

SR1 multipurpose enclosures Enclosures for automation and distribution applications

SR1 multipurpose enclosures Enclosures for automation and distribution applications AU TO M AT I O N B OA R D S SR1 multipurpose enclosures Enclosures for automation and distribution applications Complete range of monobloc enclosures for small and mediumsize automation, command and distribution

More information

Kaedra Weatherproof DIN Type Enclosures

Kaedra Weatherproof DIN Type Enclosures Multi 9 System Catalog Section 6 Additional System Devices Kaedra Weatherproof DIN Type Enclosures Applications Expandable enclosures for service, industrial, or equipment applications Protects against

More information

GENERAL CHARACTERISTICS

GENERAL CHARACTERISTICS OUTDOOR CASES GENERAL CHARACTERISTICS The ATOS case in the OUTDOOR range is designed specifically to withstand the most severe environmental requirements. The case provides full protection against very

More information

Product Datasheet. 2. GRP large rain canopy. 3. GRP door. 4. G.I Mounting plate. 5. G.I Gland plate. 6. EPDM rubber gasket

Product Datasheet. 2. GRP large rain canopy. 3. GRP door. 4. G.I Mounting plate. 5. G.I Gland plate. 6. EPDM rubber gasket POLYESTER ENCLOSURE SINGLE DOOR Product Datasheet GRP Single Door Enclosures are used for outdoor application with weatherproof and antistatic properties, finding their major application in the protection

More information

Spacial CRN and CRNG wall-mounting steel enclosures suitable for any application

Spacial CRN and CRNG wall-mounting steel enclosures suitable for any application Spacial CRN and CRNG wall-mounting steel enclosures suitable for any application Time Lasting Industrial welding process. Epoxy-polyester painting. Foamed-in polyurethane gasket. All of the above guarantees

More information

Linkeo 19 freestanding cabinets

Linkeo 19 freestanding cabinets Linkeo 19 freestanding cabinets Catalogue number(s): 6 467 50/51/55/56/60/61/62/63 Page 1.Generalcharacteristics...1 2.Range...2 3. Technical characteristics.................3 4.Dimensions...4 5.Baying...8

More information

EASYBOX Series. Weather-proof enclosures

EASYBOX Series. Weather-proof enclosures EASYBOX Series Weatherproof enclosures EASYBOX Series WEATHERPROOF ENCLOSURES IP65 REFERENCE STANDARDS INTERNATIONAL STANDARD IEC 60670 (989) plus Modification (994) Enclosures for accessories for fixed

More information

SECTION 18 ENCLOSURES

SECTION 18 ENCLOSURES COLTERLEC ELECTRICAL ENGINEERING PRODUCTS SECTION ENCLOSURES COLTERLEC ELECTRICAL ENGINEERING PRODUCTS 549 TM CONTENTS PHOENIX ENGINEERING & MANUFACTURING SOLUTIONS Stainless Steel Stainless Steel Wall

More information

1.6 Accessories include tool-free snap-in technology options for air flow, cable management, shelves, power distribution units, etc.

1.6 Accessories include tool-free snap-in technology options for air flow, cable management, shelves, power distribution units, etc. Rittal TS IT Rack Guide Specifications TS IT network server enclosure 1.0 General Description 1.1 Modular Free Standing Equipment Cabinet 1.2 Various combinations of dimensions: 1.2.1 Height: 48 /1200mm,

More information

BOXES AND BOARDS. Versatility and modularity of solutions and materials STANDARD HEAVY DUTY

BOXES AND BOARDS. Versatility and modularity of solutions and materials STANDARD HEAVY DUTY BOXES AND BOARDS Versatility and modularity of solutions and materials STANDARD HEAVY DUTY 8 BOXES AND BOARDS Versatility and modularity of solutions and materials STANDARD PRIMA topter empty distribution

More information

ENYSTAR Load Centers up to 250 A

ENYSTAR Load Centers up to 250 A PASSION FOR POWER. up to 250 A according to IEC 61439-3 for commercial and industrial buildings Download at www.hensel-electric.en made in GERMANY since 1931 up to 250 A according to IEC 61439-3 for commercial

More information

2.1 Accessories System for Enclosures CRN-CRS

2.1 Accessories System for Enclosures CRN-CRS nclosures Wall Mounted 2.1 Accessories ystem for nclosures CRN-CR Mounting plates A complete range of mounting plates comprising 4 versions able to provide all the mountings needed for this installation

More information

Mureva, Thalassa. Surface mounted boxes for rough and clamp environments. Catalogue 03/2017. schneider-electric.com

Mureva, Thalassa. Surface mounted boxes for rough and clamp environments. Catalogue 03/2017. schneider-electric.com Mureva, Thalassa Catalogue 03/201 Surface mounted boxes for rough and clamp environments schneider-electric.com Green Premium TM Endorsing eco-friendly products in the industry Schneider Electric s Green

More information

workshop specifications Plexo³ IP 65 cabinets

workshop specifications Plexo³ IP 65 cabinets workshop specifications Plexo³ IP 65 THE GLOBL SPECILIST IN ELECTRICL ND DIGITL BUILDING INFRSTRUCTURES With their IP 65 weatherproof protection and optimised dimensions, Plexo³, from 2 to 4 x 18 modules,

More information

US Catalog March 2017 Wall-mount enclosures for automation

US Catalog March 2017 Wall-mount enclosures for automation US Catalog March 2017 all-mount enclosures for automation all-mount enclosures for automation SR2 Enclosures SRX Enclosures Gemini Enclosures 1 2 US Catalog all-mount Enclosures for Automation 1/1 1 1/2

More information

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING TUNNEL54 Safety and fire resistance VENTILATION LIGHTING 238 TUNNEL54 Safety and fire resistance VENTILATION TUNNEL54 fire resistant sockets for ventilators Page 240 LIGHTING TUNNEL54 junction boxes with

More information

Viale Borri Varese - Italy IDROBOARD weatherproof cabinets Cat. Nos :

Viale Borri Varese - Italy IDROBOARD weatherproof cabinets Cat. Nos : Viale Borri 231 21100 Varese - Italy IDROBOARD weatherproof cabinets Cat. Nos : Index Pages 1. Description - Use... 2 2. Range...2 3. Overall dimensions...2 4. General characteristics...3 5. Setting in

More information

Cabinets PROLINE. Modifications. Overview Cabinets Climate Control Cases Subracks/ 19" chassis Modules...

Cabinets PROLINE. Modifications. Overview Cabinets Climate Control Cases Subracks/ 19 chassis Modules... Overview... 0 Cabinets Cabinets... 1 Climate Control... 2 Cases... 3 Subracks/ 19" chassis... 4 Modules... 5 41003002 Systems... 6 Power supply units... 7 Backplanes... 8 41096005 41096010 Grid Assembly

More information

Eldon MultiFlex platform ACCESSORIES FULLY COMPATIBLE BETWEEN RANGES. MultiCOM Aluminium. MultiFlex

Eldon MultiFlex platform ACCESSORIES FULLY COMPATIBLE BETWEEN RANGES. MultiCOM Aluminium. MultiFlex Floor Standing NEWS The new Eldon MultiFlex platform - Easy to work with! In a major development, Eldon has standardized all of its floor standing product lines around its respected and best-selling MultiFlex

More information

IP65/IP66 ABS/Polycarbonate Screw Lid Boxes

IP65/IP66 ABS/Polycarbonate Screw Lid Boxes IP65/IP66 ABS/Polycarbonate Screw Lid Boxes p Versatile, lightweight & durable p Choice of materials: polycarbonate for rugged applications or ABS as an economic alternative p IP protection for outdoor

More information

Linkeo 19 freestanding cabinets Flat-pack solutions

Linkeo 19 freestanding cabinets Flat-pack solutions Page 1.Generalcharacteristics...1 2.Range...2 3. Technical characteristics.................3 4.Packaging...4 5.Dimensions...4 6.Baying...8 7.Plinths...9 8.Cablemanagement...9 9.Fankits... 11 10.PDUsupports...

More information

more power to the cube

more power to the cube more power to the cube Tais Cube designed in GRP thermosetting for tough enclosure applications where space, ingress protection, quick installation and long service life is important. available with blind

More information

1SLC004001B0202. Enclosures and cable systems overview

1SLC004001B0202. Enclosures and cable systems overview 1SLC004001B0202 Enclosures and cable systems overview Insulating enclosures and installation material IP40 flushmounting Estetica series IP40 flushmounting Europa series IP40 wallmounting Unibox series

More information

2 The Isle of Cold Server enclosures. outdoor enclosure

2  The Isle of Cold Server enclosures. outdoor enclosure CATALOGUE HB2 outdoor enclosure HB2 based on the frame construction with mounted panel walls, made of aluminium sheet. The enclosure is an answer for market s needs connected with telecommunication industry

More information

Application Guide EH1, EH2, EH3, EH6. PolySafe. Mersen Canada Toronto Inc.

Application Guide EH1, EH2, EH3, EH6. PolySafe. Mersen Canada Toronto Inc. PolySafe Application Guide EH1, EH2, EH3, EH6 Multipurpose polyester cabinets Range of fourteen multipurpose, factory assembled cabinets in one depth 320mm, for in- and outdoor stationary use. Applications

More information

2. RANGE. RAL 7035 Cabinets Vertical version (external dimensions in mm) Square version (external dimensions in mm) Supplied with plain plate (2) (1)

2. RANGE. RAL 7035 Cabinets Vertical version (external dimensions in mm) Square version (external dimensions in mm) Supplied with plain plate (2) (1) 87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Atlantic Cat. No(s): 0 355 00/0/0/03/04/05/06/07/08/09/0//4 0 355 5/7/8/0///3/4/6/7/8/9/30/3/3/33/34/36 0 355 37/90/9/9/93/94/95/96/97/98-0

More information

OUR VISION STAINLESS STEEL MILD STEEL MODULAR FLOOR STANDING NON METALLIC P F BLACKBURN SOUTH VIC 3130

OUR VISION STAINLESS STEEL MILD STEEL MODULAR FLOOR STANDING NON METALLIC P F BLACKBURN SOUTH VIC 3130 Excalibur REAZ AUSTRALIA Enclosures PTY LTD 59 P.O. Northville BOX 2340 Drive Barnsley NSW 2278 BLACKBURN SOUTH VIC 3130 T - 03 9878 4141 sales@reaz.com.au EX-EC/S General Purpose Wall Mount Enclosures

More information

Application Guide EH1, EH2, EH3, EH6. PolySafe. Mersen Canada Toronto Inc.

Application Guide EH1, EH2, EH3, EH6. PolySafe. Mersen Canada Toronto Inc. PolySafe Application Guide EH1, EH2, EH3, EH6 Multipurpose polyester cabinets Range of fourteen multipurpose, factory assembled cabinets in one depth 320mm, for in- and outdoor stationary use. Applications

More information

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety JBES Series Medium Voltage 11 kv ECES Series Compliance Data: ATEX - IEC: ATEX IEC CE Ex e II Ex ia IIC; Ex ib IIC T6 to T4 Ex td A21 T80 C to T130 C Ex de IIC; Ex demb IIC Operating Temperatures: -50

More information

Gland Plate 1.4mm mild steel. -Opening: Situated at the far rear of the enclosure to make cabling onto the mounting plate easier.

Gland Plate 1.4mm mild steel. -Opening: Situated at the far rear of the enclosure to make cabling onto the mounting plate easier. 14 SM SHEET STEEL ENCLOSURES ITH MOUNTING PLATE FOR ALL MOUNTING SM Delivery contents: Complete enclosure with mounting plate and fixing material, Blank flange with gasket and screws. Nylon washers for

More information

Product Datasheet. Cable TV Junction Box (Page 4)

Product Datasheet. Cable TV Junction Box (Page 4) JUNCTION BOX Product Datasheet Junction Box Bolted Type (Page 2) Cable TV Box (Page ) Cable TV Junction Box (Page 4) Telephone Box (Page 5) Telephone Junction Box (Page 6) GRP Junction Box Enclosures are

More information

Technical data: Maximum insulation voltage: 690V; 50Hz Flame retardance: V-0 IP code: IP40 Colour: Gray Mounting type: Surface and flush

Technical data: Maximum insulation voltage: 690V; 50Hz Flame retardance: V-0 IP code: IP40 Colour: Gray Mounting type: Surface and flush Metal distribution boxes for flush and surface mounting Technical data: Maximum insulation voltage: 690V; 50Hz Flame retardance: V-0 IP code: IP40 Colour: Gray Mounting type: Surface and flush Number of

More information

BOXES SOLUTIONS. BOXES

BOXES SOLUTIONS.  BOXES BOXES SOLUTIONS - wide range of dimensions: over 40 enclosures with blank door, 19 models with glazed door, enclosures with single blank door, double door with rod system and enclosure with single glazed

More information

Outdoor system solutions

Outdoor system solutions Outdoor system solutions At home in any outdoor application 2 Rittal Outdoor system solutions Energy Mounting benefits Flexible basic enclosure, optionally with doors front and rear, for rapid interior

More information

Technical data. Material e-reinforced polyester in grey or black. Seal Neoprene (CR) round cord (siliconized)

Technical data. Material e-reinforced polyester in grey or black. Seal Neoprene (CR) round cord (siliconized) BERNSTEIN Series CP and CPS polyester enclosures are produced from highgrade e-reinforced polyester. Thanks to their reduced surface resistance (Ro < 109 Ohm), the black polyester enclosures meet the requirements

More information

348,6 HE = U Carrying handles, horizontal

348,6 HE = U Carrying handles, horizontal T 8,6 Rittal RiCase 69. ( / 9 ) (E) E = U Technical specifications: Depth: 00, 0, 50 Installation width: 69. ( / 9 ) Installation options: 69. ( / 9 ) slide-in equipment and modular assemblies to IEC 60

More information

SCHÄFER IT-Systems The specialists for IT infrastructure

SCHÄFER IT-Systems The specialists for IT infrastructure SCHÄFER IT-Systems The specialists for IT infrastructure Catalogue 2012/2013 1 2 SCHÄFER IT-Systems The specialists for IT infrastructure SCHÄFER IT-Systems The specialists for IT infrastructure SCHÄFER

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

XL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments

XL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments 87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax : 05 55 06 88 88 XL³ 400 metal distribution cabinets, free-standing Cat. No(s) : 20103/04/05/06/07/08/18/19/23/ CONTENTS PAGE 1. General characteristics...

More information

Features EN/IEC Applications

Features EN/IEC Applications PO Modular polyester boxes nsulated boxes Standards eatures ntro N/ 639- N/ 6059 N/ 608 pprovals - oxes with polyester cover: types 3, 3R,,, 6, 6P, and 3 - oxes with polycarbonate cover: types 3, 3R,,,

More information

ARIA Series configuration options and specifications

ARIA Series configuration options and specifications Vynckier Enclosure Systems 271 McCarty St., Houston, Texas 77029 Phone: (713) 374-7850 Toll Free: (888) 837-1114 Fax: (800) 444-1261 www.vynckier.com ARIA Series configuration options and specifications

More information

Marina Cabinets LIMOGES Cedex Telephone: Fax:

Marina Cabinets LIMOGES Cedex Telephone: Fax: 87045 LIMOGES Cedex Telephone: 0 5 55 06 87 87 - Fax: 0 5 55 06 88 88 Marina s CONTENTS Page 1. Main characteristics...1 2. Range....1 3. Technical characteristics...1 4. Dimensions....3 5. Equipments...4

More information

Teknisk katalog Utdrag. Gemini. Low voltage electric insulating switchboards 1SEC800010C2101

Teknisk katalog Utdrag. Gemini. Low voltage electric insulating switchboards 1SEC800010C2101 Teknisk katalog Utdrag Gemini Low voltage electric insulating switchboards 1SEC800010C2101 Introduction Characteristics of Gemini switchboards Gemini, something completely different in switchboards Gemini

More information

2: Ecokit Ecokit 11 Overview A 2_ Ecokit 11 Sub Rack Configuration A 2_ Width A 2_ Height / Depth A 2_6

2: Ecokit Ecokit 11 Overview A 2_ Ecokit 11 Sub Rack Configuration A 2_ Width A 2_ Height / Depth A 2_6 2: Ecokit 11 2.1 Ecokit 11 Overview 2_3 2.2 Ecokit 11 Sub Rack Configuration 2_5 2.2.1 Width 2_5 2.2.2 Height / Depth 2_6 2.2.3 Handles 2_6 2.2.4 Line Drawing 2_7 2.3 daptation Kits 2_8 2.3.1 daptation

More information

ENCLOSURE CATALOGUE Ensto Cubo

ENCLOSURE CATALOGUE Ensto Cubo ENCLOSURE CATALOGUE Ensto Cubo www.ensto.com 2 Ensto at your service We are a specialist in the field of enclosures and customer-specific enclosure solutions. Our standard product range includes thermoplastic,

More information

IMRAK Freestanding Cabinets

IMRAK Freestanding Cabinets IMRAK 1400 Freestanding Cabinets IMRAK 1400 Freestanding Cabling Rack IMRAK 1400 Freestanding Cabinet CONTENTS Introduction to IMRAK 1400 2 3 Technical specification 4 IMRAK 1400 Ready to use 5 User configurable

More information

Electrical installation solutions for buildings Technical details Automation boards

Electrical installation solutions for buildings Technical details Automation boards /1 Electrical installation solutions for buildings Technical details Automation boards Index Compliance with standards and technical characteristics Gemini /2 IP degree of protection Gemini /4 IK degree

More information

APO ENCLOSURES. The bases are made of grey (RAL 7036), hot moulded glass fibre reinforced polyester

APO ENCLOSURES. The bases are made of grey (RAL 7036), hot moulded glass fibre reinforced polyester APO ENCLOSURES APO - Modular polyester boxes - Complete with Base and Grey Lid IEC 60439-1 EN 60439-1 The range consists of nine boxes based on the 300 and 185 mm modules. IEC 60529 EN 60529 The bases

More information

Safety enclosures. 482 General Catalogue SOCOMEC. Safety enclosures

Safety enclosures. 482 General Catalogue SOCOMEC. Safety enclosures coff_163_a_1_cat coff_156_b_1_cat Function equipped with SOCOMEC switches provide emergency breaking, breaking for mechanical maintenance and safety isolation in the vicinity of any low voltage final circuit.

More information

Product Data For FARNELL

Product Data For FARNELL ae Product Data For FARNELL ae Uniset is / Varioset is ae EL ELECTRONIC KOMBI SYSTEM WALL MOUNTING Pole clamp For reliable, convenient fastening to round or square poles. For pole diameter/size:

More information

SPECIFICATION GUIDE-IMRAK

SPECIFICATION GUIDE-IMRAK Enclosure Solutions SPECIFICATION GUIDE-IMRAK Issue 3. June 06 Contents Technical specifications 3 IMRAK ServerMax Primary rack builds 4, 5 IMRAK 1400 Primary rack builds 6, 7 Open frames 8 Side panels

More information

Distribution Blocks & Bus-bar Solutions

Distribution Blocks & Bus-bar Solutions Distribution Blocks & Bus-bar Solutions Insulated Multi Laminate Flexible Copper Bus-bars Threaded Copper Bus-bars Solid Copper Bus-bars Bus-bar Insulators & Supports Insulated Flexible Copper Braided

More information

LineaSPACE flush-mounting cabinets 8, 12 & 18 modules

LineaSPACE flush-mounting cabinets 8, 12 & 18 modules Catalogue number(s): F315P8/PB8/PS8/P12/PB12/PS12/P24/ PB24/PS24/F315P36D3/F315PB36D3/PS36D3/P18/PB18/PS18/P36D2/ PB36D2/F315PS36D2/P54/PB54 Contents Pages 1. Description, use... 2 2. Range...2 3. Dimensions...2

More information

P17. Tempra PRO. a range you can rely on CATALOGUE PAGES INSIDE. GLOBAL SPECIALIST in electrical and digital building infrastructures

P17. Tempra PRO. a range you can rely on CATALOGUE PAGES INSIDE. GLOBAL SPECIALIST in electrical and digital building infrastructures P17 Tempra PRO a range you can rely on -> GLOBAL SPECIALIST in electrical and digital building infrastructures CATALOGUE PAGES INSIDE P17 TEMPRA PRO, suitable for all the P17 tempra Pro range incorporates

More information

INTRODUCTION WALL MOUNT APPLICATIONS SLIMLINE BOX... 5 COMMSRAK... 5 IMRAK IMRAK

INTRODUCTION WALL MOUNT APPLICATIONS SLIMLINE BOX... 5 COMMSRAK... 5 IMRAK IMRAK INTRODUCTION WALL MOUNT APPLICATIONS SLIMLINE BOX... 5 COMMSRAK... 5 IMRAK 400... 6-7 IMRAK 600... 8-9 FLOOR MOUNT APPLICATIONS COMMSRAK... 11 IMRAK 600... 12-15 IMRAK 1400... 16-32 Specification... 17-18

More information

Door available front and rear

Door available front and rear Features - The range consists of nine cabinets, ranging from 20" x 30" to 50" x 40". - Cabinet is self-extinguishing, hot molded halogen-free fiberglass reinforced polyester. - Gray dyed in mass (RAL 7036)

More information

Glass Reinforced Polyester Enclosures

Glass Reinforced Polyester Enclosures 42 The GRP range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,

More information

Premium Quality - Value Price

Premium Quality - Value Price ACE 19" RACK SYSTEMS 1 VS 7000, Super Efficient Global IT Rack Designed ready to install and meeting international standard and of Top-quality. Two 19" mounting multi-functional profiles create a solid

More information

Industrial Enclosures

Industrial Enclosures Industrial Enclosures Small enclosures from page 08 Polycarbonate enclosures PK... 0 Cast aluminium enclosures GA... 4 Terminal boxes KL... 6 E-ox E... 9 us enclosures G... 0 RiLAN Industrial IN... 4 Compact

More information

GE Industrial Solutions. New. QuiXtra 4000ED.02. Low Voltage Distribution Boards up to 4000A. GE imagination at work

GE Industrial Solutions. New. QuiXtra 4000ED.02. Low Voltage Distribution Boards up to 4000A. GE imagination at work GE Industrial Solutions New Quitra 4000ED.02 Low Voltage Distribution oards up to 4000 GE imagination at work Quitra 4000 Quitra 4000 is a range of sheet steel system enclosures, delivered as a flat kit:

More information

Polyline Polycarbonate Enclosures

Polyline Polycarbonate Enclosures TM Polyline Polycarbonate Enclosures Authorized Distributor: From Allied Moulded Products, Inc. Experts in manufacturing nonmetallic enclosures for industrial applications WESCHLER INSTRUMENTS 800-903-9870

More information

Viking 3 - Screw connection Disconnect terminal blocks

Viking 3 - Screw connection Disconnect terminal blocks 87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Viking 3 - Screw connection 1. General features... 1 2. Range...2 3. Standards... 2 4. Technical features... 3 5. Dimensions...

More information

cabinets and equipment Atlantic, Atlantic stainless steel, Marina

cabinets and equipment Atlantic, Atlantic stainless steel, Marina cabinets and equipment Atlantic, Atlantic stainless steel, Marina EXTERNAL DIMENSIONS D ATLANTIC CABINETS (p. 276) MARINA CABINETS (p. 286) METAL IK 10 STAINLESS STEEL IP 66-IK 10 POLYESTER - IP 66 - IK

More information

Industrial enclosures INDUSTRIAL INNOVATIVE INDIVIDUAL INSPIRING. Product Catalog.

Industrial enclosures INDUSTRIAL INNOVATIVE INDIVIDUAL INSPIRING. Product Catalog. Industrial enclosures INUSTRIAL INNOVATIVE INIVIUAL INSPIRING Product Catalog www.conteg.cz Content integ Industrial s and their Uses 3 integ Free-standing s Advantages and Specifications 4 Free-standing

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

Rittal CM Compact System Enclosures

Rittal CM Compact System Enclosures Rittal CM Compact System Enclosures Compact class = Top class: Infinite possibilities R Compact enclosure on the outside, Top enclosure on the inside! Index Convincing details... 3 5 Compact system enclosures

More information

Cubicles Frameworks. Enclosures W=400mm. System P. 400 mm deep framework. 600 mm deep framework. Hinged front plate support frame.

Cubicles Frameworks. Enclosures W=400mm. System P. 400 mm deep framework. 600 mm deep framework. Hinged front plate support frame. Frameworks DD380800 400 mm deep framework DD380572 DD380573 DD380574 08407. Framework width W = 300 mm 08403 W = 400 mm 08404 W = 650 mm 08406 W = 800 mm 08408 W = 800 mm (650 + 150) 08407 b composition

More information

14853 E. Hinsdale Ave. Centennial, CO USA Toll Free: / FAX:

14853 E. Hinsdale Ave. Centennial, CO USA Toll Free: / FAX: 14853 E. Hinsdale Ave. Centennial, CO 80112-4240 USA Toll Free: 800-677-8942 / 303-680-5159 FAX: 303-680-5344 Hensel empty enclosures - the best choice for your electrical installation applications The

More information

Solar PV Enclosures 64

Solar PV Enclosures 64 Solar PV Enclosures 64 CDN36PT CDN24PT Watertight Distribution Enclosures (UV Rated) IP65, (Surface Mounted), (DC Rated DB Boards) Technical data Degree of protection is IP65 Test of resistance to glow

More information

MILD STEEL WALL MOUNTING ENCLOSURES

MILD STEEL WALL MOUNTING ENCLOSURES MILD STEEL WALL MOUNTING ENCLOSURES WALL L MOUNTI IN NG WALL L MR5 M5 MO R 5 MAS IP66/NEMA 4, 12, 13 Single door Height: 200-1200 Width: 200-800 Depth: 155-400 ALL MILD STEEL WALL MOUNTING ENCLOSURES MR

More information

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2. Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.12 Product Overview ABB's type-tested ring main unit (RMU) is an SF 6 insulated RMU utilising the latest developments

More information